• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6463
  • 104
  • 102
  • 101
  • 87
  • 78
  • 71
  • 57
  • 29
  • 11
  • 10
  • 10
  • 7
  • 4
  • 4
  • Tagged with
  • 6720
  • 3516
  • 1353
  • 889
  • 877
  • 836
  • 783
  • 730
  • 691
  • 616
  • 596
  • 569
  • 514
  • 473
  • 410
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
481

Simulação da qualidade da água subterrânea no aterro sanitário de Taubaté.

Maria de Fátima de Pinho 00 December 1997 (has links)
Nesta dissertação é aplicado o modelo numérico bi-dimensional UNMOC (Charbeneau 1990) para avaliar o impacto do aterro sanitário de Taubaté sobre a qualidade das águas subterrâneas. UNMOC é um modelo numérico e analítico de fluxo e transporte de massa que combinado com dados químicos e cargas hidráulicas foi simultaneamente aplicado no aterro novo e no aterro inativo de Taubaté, numa área total de 265.700m2. Sabe-se que o amônio, cloreto, sódio, magnésio e cálcio contribuem para o aumento da mineralização da água subterrânea na área. Amônio e cloreto tornam-se indicadores particulares da poluição do lixo municipal. A evolução da pluma de de contaminação causada pelo aterro sanitário de Taubaté foi modelada através da substância cloreto, para o ano corrente e para os próximos 5 e 10 anos, mostrando que nenhuma contaminação pela água subterrânea será detectada próxima do rio. Outras simulações hipotéticas foram realizadas, mostrando a versatilidade do modelo para vários tipos de condutividade e espessuras do aquífero. Os resultados e validades da aplicação serão discutidos.
482

Caracterização e aproveitamento de água cinza para uso não-potável em edificações

Bazzarella, Bianca Barcellos 20 December 2005 (has links)
Made available in DSpace on 2016-12-23T14:04:31Z (GMT). No. of bitstreams: 1 Bazzarella_BB_2005.pdf: 1796304 bytes, checksum: 5c1096eb07ceba35ec8e46762f4f2ba8 (MD5) Previous issue date: 2005-12-20 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / Uma das formas de se conservar água nas residências é utilizando fontes alternativas de suprimento. O reúso de águas cinza para fins não-potáveis, tais como lavagem de veículos, rega de jardins e descarga de vasos sanitários, é apenas um exemplo. Este trabalho tem como objetivo pesquisar alternativas para redução do consumo de água potável e da produção de esgotos sanitários em edificações, a partir do aproveitamento do tratamento e reúso de águas cinza em descargas de vasos sanitários. Para isso, foi realizada uma etapa preliminar de caracterização qualitativa de águas cinza coletadas em diversas fontes (lavatório, chuveiro, pia de cozinha, tanque e de máquina de lavar roupa) do ponto de vista físico-químico e microbiológico. A água cinza apresentou significativa concentração de matéria orgânica rapidamente biodegradável e sulfatos, evidenciando o grande potencial de produção de H2S, caso ela seja estocada sem tratamento. As concentrações de nutrientes (N e P) foram menores que no esgoto convencional, uma vez que a maior parte deles é oriunda dos excrementos (urina e fezes). A presença de E. coli mostrou que a desinfecção prévia ao reúso é necessária, principalmente se as normas para o reúso em descarga de vasos sanitários forem muito rígidas. Uma outra etapa realizada neste trabalho foi o monitoramento de um sistema de reúso implantado em um prédio localizado na UFES. O prédio contém duas salas de professores com banheiros individuais e banheiros coletivos, masculino e feminino, contabilizando um total de seis pias, dois chuveiros, seis vasos sanitários e dois mictórios. As águas cinza do prédio (efluente de chuveiro e lavatório) são encaminhadas separadamente para uma Estação de Tratamento de Águas Cinza (ETAC), cujo processo é baseado na associação de um Reator Anaeróbio Compartimentado (RAC), de um Filtro Biológico Aerado Submerso (FBAS), de um Filtro Terciário (FT) e de desinfecção à base de cloro. O tratamento adotado apresentou elevada eficiência na remoção de turbidez, cor, DBO5, DQO e E. coli., e características compatíveis com diversos padrões estabelecidos para o reúso não-potável. As características dos lodos gerados desse tratamento apresentaram concentrações de ST e relação SV/ST de 0,59% e 77% (1ª câmara do RAC), 0,54% e 74% (2ª câmara do RAC), 0,004% e 32% (lodo aeróbio), 0,008% e 60% (1ª coleta lodo terciáro) e 0,004% e 25% (2ª coleta lodo terciáro). / Alternative sources of residential water supply may aid water conservation. One example is the reuse of greywater for non potable purposes (car washing, garden irrigation and toilet flushing). This work investigates alternatives for reducing potable water consumption and the production of wastewater in buildings, using greywater treatment applied to toilet flushing. Initially, a physical-chemical and microbiological qualitative characterization of greywater collected in several sources (lavatory, shower, kitchen sink, tank and wash machine) was carried out. The greywater presented significant concentrations of quickly biodegradable organic substances and sulphates, highlighting its high potential for H2S production when stored untreated. The nutrient concentrations (N and P) were minor compared with the ones in a conventional sewer, since they largely came from faeces and urine. The presence of E. coli showed the need for disinfection before reuse, depending on the quality standards for toilet flushing. Additionally a reuse system was monitored in a building at UFES University. The building contains two professors rooms with individual bathrooms and collective bathrooms, male and female, giving a total of six lavatories, two showers, six toilets and two urinals. This building s greywater (the effluent of showers and lavatories) is directed to a Greywater Treatment Plant (ETAC), whose processing is based on a combination of techniques - Compartment Anaerobic Reactor (RAC), Submerged Aerated Filter (FBAS), Tertiary Filter (FT) and disinfection based in chlorine. The adopted treatment showed high efficiency in the removal of turbidity, color, BOD5, QOD, E. coli, and was compatible with diverse standards established for non potable reuse. The characteristics of the generated sludge of this treatment presented concentrations of ST and the relation SV/ST of 0,59% and 77% (1st chamber of the RAC), 0.54% and 74% (2nd chamber of the RAC), 0.004% and 32% (aerobic sludge), 0.008% and 60% (1st collects tertiary sludge) and 0.004% and 25% (2nd collects tertiary sludge).
483

Caracterização, tratamento e reúso de águas cinzas e aproveitamento de águas pluviais em edificações. / Characterization, treatment and reuse of greywater and rainwater use in buildings.

Simone May 15 May 2009 (has links)
não potáveis vêm ao encontro das premissas de sustentabilidade e ao conceito de conservação de água. Sistemas de reúso de águas cinzas e sistemas de coleta e aproveitamento de águas pluviais devem seguir quatro critérios: segurança higiênica, estética, proteção ambiental e viabilidade técnica e econômica. As águas cinzas e as águas pluviais devidamente tratadas podem ser utilizadas no consumo não-potável em edificações como em bacias sanitárias, em torneiras de jardins, na irrigação de gramados e plantas, na lavagem de veículos, na lavagem de roupas, na limpeza de calçadas, na limpeza de pátios, na produção de concretos, na compactação de solos, na recarga de aqüíferos e no uso ornamental como em chafarizes e em espelhos d\'água desde que sua utilização não ofereça riscos à saúde de seus usuários. As águas cinzas podem ser divididas em dois grupos: águas cinzas escuras e águas cinzas claras. As águas cinzas claras são as águas residuárias originadas de banheiras, chuveiros, lavatórios e máquinas de lavar roupas. Já as águas cinzas escuras incluem ainda as águas residuárias provenientes da pia da cozinha e máquina de lavar pratos. O efluente oriundo de vasos sanitários não é denominado de águas cinzas, mas águas negras. A composição das águas cinzas é principalmente influenciada pelo comportamento do usuário, podendo também apresentar variação conforme a região onde a cultura, os costumes, as instalações e a utilização de produtos químicos são diferentes. Microrganismos patogênicos podem ser encontrados nas águas cinzas e nas águas pluviais como, por exemplo, a Escherichia Coli, que é comumente utilizada como indicador de contaminação fecal. Assim, o tratamento das águas cinzas e das águas pluviais deve ser praticado com o intuito de eliminar a matéria orgânica e remover ou inativar os microrganismos patôgenos presentes nessas águas, evitando-se o contato humano direto com águas poluídas e a disseminação de doenças. Alguns cuidados com o uso de sistemas de reúso de águas cinzas e sistemas de aproveitamento de águas pluviais devem ser tomados, a saber: verificar a qualidade da água tratada, fazer manutenção adequada ao sistema, dispor de operação eficaz e segura ao sistema e ao operador, verificar a não ocorrência de conexões cruzadas no sistema de distribuição, fazer uso de avisos com indicação água não potável, fazer uso de tubulações de cores e de conexões diferenciadas, de modo que o sistema ofereça segurança a seus usuários. Este projeto visa a caracterização e o tratamento de águas cinzas e de águas pluviais para consumo não potável em edificações. A primeira etapa do projeto destinou-se à caracterização das águas cinzas residenciais através de análises físicas, químicas e bacteriológicas para a verificação de sua qualidade. A segunda etapa foi dividida em dois grupos: tratamento das águas cinzas residenciais e tratamento das águas pluviais. Neste trabalho foi abordada a caracterização e o tratamento das águas cinzas claras, isto é, as águas residuárias oriundas de chuveiros, de lavatórios e da máquina de lavar roupas. O tratamento das águas pluviais se deu com base nos resultados de caracterização obtidos em May (2004), anexo 2. Para o tratamento das águas cinzas fez-se uso de tratamento biológico aeróbio e para o tratamento das águas pluviais, filtração e desinfecção com cloro. Alguns dos parâmetros analisados durante o período de monitoramento do sistema de tratamento de águas cinzas obtiveram uma redução bastante significativa, por exemplo: cor aparente - 95,1%, turbidez - 98,2%, SST - 94,1%, DBO - 93,4%, DQO - 86,3%, COT - 84,9%, Coliformes termotolerantes - 99,8% e Coliformes totais - 97,8%. Durante os ensaios foi mantido um residual mínimo e máximo de cloro de 0,8 1,7 mg/L. No sistema de tratamento de águas pluviais alguns parâmetros analisados durante o período de monitoramento obtiveram as seguintes reduções: cor aparente - 62%, turbidez - 75,7%, Coliformes termotolerantes - 100% e Coliformes totais - 100%. Durante os ensaios foi mantido um residual mínimo e máximo de cloro de 0,6 1,2 mg/L. Baseado nos resultados das análises realizadas e nos resultados obtidos com o tratamento dessas águas, seus usos para fins não potáveis devem ser estimulados. / The reuse of greywater and the rainwater catchment for non potable uses meets the premises of sustainability and the concept of water conservation. Properly conceived greywater reuse systems and rainwater catchment systems should follow four basic criteria: hygienic reliability, aesthetics, environmental protection and technical/economic feasibility. The greywater and the rainwater, when properly treated, can be used for consumption at buildings, for non potable purposes such as flushing toilet bowls, floors and backyards cleaning, garden irrigation, ornamental uses as in water mirrors and water fountains as long as its use avoid any risk to users health. Greywater can be divided in two groups: dark greywater and light greywater. The greywater is originated from bathtubs, showers, lavatories and washer machines. Dark greywater, has its origin from kitchen lavatory and dishwasher machine. Water from toilet bowls is not called greywater but wastewater. Greywater composition is mainly influenced by user habits and usually results on variations depending on the region, the culture, the costumes, the installation and the kind of chemical products used. Pathogenic microorganisms can be found on greywater and on rainwater as, for example, Escherichia Coli, commonly used as faecal contamination indicator. Greywater and rainwater treatment should be taken so that organic material can be removed or pathogenic microorganisms found can be inactivated, avoiding direct human contact and disease dissemination. Care on processing greywater reuse systems and rainwater catchment systems should be taken, as: verifying treated water quality, appropriated system maintenance, secure and efficient operation for the operator and for the system, the avoidance of crossing conections on distribution system, usage of alert signs about non potable water, different colors and different connection dimensions so that the reuse system offers secure operation for its users. This paperwork aims to the characterization and the treatment of greywater for non potable use in buildings, divided in two sections. The first section of the project aimed the residential greywater characterization through fisical, chemical and bacteriological analysis for quality evaluation. The second section was divided in two groups: the treatment of residential greywater and the treatment of collected rainwater. This project focus on the characterization and on the treatment of light greywater, defined as water collected from showers, lavatories and washer machines. Rainwater treatment was based on the results achieved from May (2004), annex #2. Filtration and chloride disinfection treatment was applied on rainwater and aerobic biological treatment was applied on greywater. Some of the parameters analysed during the monitoring period of the greywater treatment system, achieved a significant reduction as, for example: color: - 95.1%; turbidity: - 98.2%; TSS: - 94.1%; BOD: - 93.4%; COD: - 86.3%; TOC: - 84.9%; Thermotolerants Coliforms: - 99.8%; e Total Coliforms: - 97.8%. During the analysis, the residual chloride was kept on 0.8 to 1.7 mg/L range. On rainwater treatment system some parameters analysed during the monitoring period achieved the following reductions: color: - 62%; turbidity: - 75.7%; Thermotolerants Coliforms: - 100%; and Total Coliforms: - 100%. During the analysis, the residual chloride was kept on 0.6 to 1.2 mg/L range. Based on the results from the water analysis and on the results from the resulting treated water, its non potable uses should be stimulated.
484

Qualidade microbiológica, concentração de nitratos em águas de consumo alternativo (minerais e de poços) da cidade de Jaboticabal-SP /

Giacometti, Laudicéia. January 2001 (has links)
Resumo: Fatores como o gosto e o odor associados à população pela desinfecção com cloro realizada em águas de abastecimento público têm estimulado um maior consumo de águas minerais e águas de poços particulares, situação que desperta o interesse pela qualidade desse tipo de abastecimento que tem sido denominado como consumo alternativo. Diante disso, o presente trabalho teve como objetivo verificar a qualidade higiênico-sanitária e a concentração de nitratos em águas engarrafadas e de poços particulares utilizadas pela população de Jaboticabal, SP. Para as águas engarrafadas foram estudadas três marcas, três volumes de embalagens (20 L; 1,5 L; 0,2 L) e 5 lotes. As águas de poços foram analisadas em períodos de seca e chuva. As variáveis analisadas nos dois casos foram: Pseudomonas aeruginosa, clostridios sulfito-redutores, coliformes totais, Escherichia coli, enterococos e teores de nitrato. Os resultados evidenciaram que não existe uniformidade de qualidade das águas condicionadas em galões de 20 L para os diferentes lotes e para as três marcas, o que se deve à deficiência do preparo das embalagens para reutilização. Dentre 225 amostras analisadas, 37% apresentaram-se fora do padrão de potabilidade. Dentre os sete poços acompanhados verificou-se que o poço 6 tem a qualidade microbiológica de sua água influenciada por precipitações pluviométricas. Os poços 5 e 7 apresentaram elevado teor de nitrato. Estes resultados totalizam 2,8% das águas de poço fora dos padrões de potabilidade. / Abstract: Points like taste and odor associate for population to chlorine disinfection applied in public water supply stimulated a greater utilization of mineral water and from wells, acts that arise the interest about the quality of this kind of supply, which has been designated as alternative means. Consequently, the present work aimed the verification of the hygienic-sanitary quality, and the concentration of nitrates in bottled water and from private wells used by the population of Jaboticabal, SP, Brazil. For bottled water, three brand marks, three size bottles (20 L, 1.5 L, 0.2 L) and 5 batches were analyzed. Waters from wells were analyzed in dry and rainy periods. The varieties analyzed in both cases were: Pseudomonas aeruginosa, sulfide reducers clostridium, whole coliforms, Escherichia coli, enterococcus and nitrate. The results indicated there's no uniformity in the quality of waters bottled in 20 L containers for the different batches and for the three brand marks, due to deficiency in their preparation for reuse. From 225 analyzed samples, 37% presented themselves as out of standard of potability. From the seven wells analyzed there has been verified that the well no. 6 has the microbiological quality of its water influenced by pluvial precipitations. The wells 5 and 7 presented high level of nitrate. These results totalized 2.8% of water from wells out of standard of potability. / Orientador: Márcia Justino Rossini Mutton / Coorientador: Luiz Augusto do Amaral / Banca: Ângela Cleusa de Fátima Banzatto de Carvalho / Banca: Bernardo Arantes do Nascimento Teixeira / Mestre
485

Requisitos e critérios de desempenho para sistema de água não potável de edifícios residenciais. / Requirements and performance criteria for non-potable water system of residential buildings.

Peixoto, Luciana de Melo 15 December 2008 (has links)
A utilização de fonte alternativa de água em edifícios residenciais vem sendo praticada de forma mais constante nos últimos anos, com objetivo de reduzir a demanda de água potável. No entanto, a utilização de água não potável exige critérios que devem ser respeitados, para preservar a saúde dos usuários, tendo em vista a possibilidade de contaminação da água potável fornecida pela concessionária. Assim, este trabalho tem como objetivo apresentar requisitos e critérios de desempenho que devem ser aplicados nas fases de projeto, execução e manutenção do sistema predial de água não potável. Para apoiar os projetistas, executores e gestores na tomada de decisão das diferentes etapas do processo foi também desenvolvida e aplicada uma ferramenta para análise de modo e efeito de falha (FMEA) dos requisitos desenvolvidos para o sistema de água não potável. Os resultados obtidos com a aplicação da ferramenta em edifício comprovaram a sua aplicabilidade e eficiência no sistema predial de água não potável. / The use of alternative source of water in residential buildings has been practiced in more constant in recent years aiming to reduce the demand for potable water (drinking water). However, the use of non-potable water requires criteria that must be respected to preserve the health of users, with a view to possible contamination of potable water supplied by the concessionaire. Therefore, this paper aims to present requirements and performance criteria, which must be implemented in phases of design, implementation and maintenance of the non-potable water system in building. To assist the designers, performers and managers in decision-making of the different stages of the process was also developed and implemented analyze with the tool failure mode effect analysis (FMEA) for the requirements developed for the non-potable water system in building. The results achieved by the tool showed its applicability and efficiency in non-potable water system in building.
486

Optimização de sistemas de automação, controlo e supervisão de estações de tratamento de água

Moreira, Cláudia Marisa Martins January 2004 (has links)
Tese de mestr.. Engenharia de Automação, Instrumentação e Controlo. Faculdade de Engenharia. Universidade do Porto. 2004
487

Avaliação de capitações em edifícios habitacionais

Costa, Iris Diana Pereira da Costa January 2012 (has links)
Tese de mestrado integrado. Engenharia Civil. Faculdade de Engenharia. Universidade do Porto. 2012
488

Avaliação de métodos para previsão de consumo de água para curtíssimo prazo : um estudo de caso em empresa de saneamento / Breno Trautwein Junior ; orientador, Guilherme Ernani Vieira

Trautwein Junior, Breno January 2004 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, 2004 / Inclui bibliografia / Em saneamento, um dos fatores críticos na operação de Ssitemas de Abastecimento de Água é o atendimento contínuo da população mantendo uma oferta de água maior ou igual ao consumo. Se for considerado que este consumo é viável ao longo do dia e que todo Si
489

Avaliação hidrogeológica da interação lagoa - aquífero e da qualidade da água no sistema de filtração em margem da Universidade Federal de Viçosa -MG / Hydrogeological evaluation of pond - aquifer interaction and water quality in the bank filtration system from Federal University of Viçosa - MG

Faria, Agnes Caroline Santos 20 February 2017 (has links)
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2017-08-09T12:30:20Z No. of bitstreams: 1 texto completo.pdf: 3526777 bytes, checksum: 1f62e755a2bb5751e881c3ed9595278d (MD5) / Made available in DSpace on 2017-08-09T12:30:21Z (GMT). No. of bitstreams: 1 texto completo.pdf: 3526777 bytes, checksum: 1f62e755a2bb5751e881c3ed9595278d (MD5) Previous issue date: 2017-02-20 / Fundação de Amparo à Pesquisa do Estado de Minas Gerais / Na Europa, a utilização da FM para o abastecimento das cidades é bastante comum e antiga (100 anos). No Brasil, o estudo da técnica se iniciou no estado de Santa Catarina em 2006. Em Viçosa, a técnica se iniciou em 2013. Foram utilizados poços de monitoramento previamente instalados a diferentes distâncias da margem da Lagoa da Universidade Federal de Viçosa, nas proximidades do ponto de captação de água das Estações de Tratamento que abastecem a universidade e parte da cidade de Viçosa. O poço de captação foi instalado com o intuito de analisar a dinâmica do fluxo da água subterrânea. A lacuna existente no estudo realizado em 2013, devido à falta de informações da porção mais alta da área, deu origem ao presente trabalho. Portanto, o objetivo dessa pesquisa foi analisar a influência de mais pontos de monitoramento no resultado da modelagem realizada anteriormente e, a qualidade da água do sistema de FM de lagoa para estudos de viabilidade da aplicação da técnica como alternativa efetiva de pré tratamento de água. A análise do fluxo foi realizada por meio do software Visual MODFLOW e a qualidade da água por meio de análises laboratoriais dos parâmetros oxigênio dissolvido, pH, T°, condutividade, turbidez, demanda bioquímica de oxigênio, fósforo total, nitrato, coliformes totais e Escheríchia coli. O modelo numérico foi construído com base no modelo conceitual formulado por meio das medições de nível d’água ao longo de um ano hidrológico, levantamento topográfico, teste de bombeamento, batimetria, condutividade hidráulica, recarga e balanço hídrico. A calibração foi realizada com base no valor do RMS Normalizado que foi igual a 26,73% para o período estacionário sem bombeamento e igual a 23,98% para o período estacionário com bombeamento. Cinco cenários foram simulados a partir do modelo com bombeamento: cenários 1, 2 e 3 considerando uma nova posição do poço de produção com vazões de 120 m3/dia, 150m3/dia e 90m3/dia respectivamente em um período de 43 dias (cenário 1) e 5 anos (cenários 2 e 3). Os RMS Normalizados encontrados para esses cenários foram 23,45%, 24,26% e 23,39%, respectivamente. Os cenários 4 e 5 consideraram o poço de bombeamento no mesmo local, porém com bombeamento de 150m3/dia e 90 m3/dia, resultando em um RMS Normalizado de 24,38% e 24,09%, respectivamente. Com relação às análises de qualidade da água, os resultados demonstram que os parâmetros turbidez, coliformes totais e E. coli foram os que apresentaram valores de remoção mais satisfatórios, com redução de mais de 90% após passagem pelo sistema de filtração em margem. / River bank filtration (RBF) is a simple technique that uses the natural material present on river margins to filter as filtration media. By pumping on a well, water is driven from a river or any water body throughout the sediments on its margins towards the collection well and being filtrated by physical, chemical and biological processes that remove pollutants. In Europe, RBF for urban areas supply have been used for more than 100 years. In Brazil, the study of this technique has began on 2006, Santa Catarina state. In Viçosa, the BF studies started in 2013. Monitoring wells installed at different distances from a pond margin located within Federal University of Viçosa campus. Pumping well was specifically installed for the purposes of the present research. Flow analysis was performed trough Visual Modflow ® and water quality was based on laboratory analysis of the following parameters: dissolved oxygen, HP, temperature, conductivity, turbidity, Oxygen Biochemical Demand (OBD), total phosphorus, nitrate, total coliforms and E. coli. The numerical model was based on a conceptual model developed specifically for this study and supported by: water level measurements during one hydraulic year, pumping test, topography, bathymetry, hydraulic conductivity tests, recharge and water balance. Calibration was performed for Normalized RMS, which was equal to 26.73% for stationary period and equal to 23.98% for pumping period. Five scenarios were simulated from the pumping model: scenarios 1, 2 and 3 considering a new pumping well with 120 m3/day, 150 m3/day and 90 m3/day flow pumping rates during 43 days (scenario 1) and 5 years (scenarios 2 and 3). Normalized RMS found for those scenarios were 23.45%, 24.26% and 23.39%, respectively. Scenarios 4 and 5 have considered a pumping well in the same place as the real tested well, but considering 150 m3/day and 90 m3/daily flow rates, so resulting in Normalized RMS equal to 24.38% and 24.09% respectively. Based on water quality analysis, turbidity, total coliform and E. coli were the one that have presented the best results, with water after river bank filtration presenting a reduction of more than 90% of those parameters when compared to water in the pond.
490

Avaliação da remoção de arsênio no tratamento convencional de água para consumo humano / Evaluation of arsenic removal in the conventional treatment of water for human consumption

Vasquez Sanjuan, Karina Esther 06 March 2017 (has links)
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2017-08-23T13:46:48Z No. of bitstreams: 1 texto completo.pdf: 2146646 bytes, checksum: 0f052ad0ef348091034191170f4bad5f (MD5) / Made available in DSpace on 2017-08-23T13:46:48Z (GMT). No. of bitstreams: 1 texto completo.pdf: 2146646 bytes, checksum: 0f052ad0ef348091034191170f4bad5f (MD5) Previous issue date: 2017-03-06 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Neste trabalho, avaliou-se a remoção de arsênio (As) no tratamento convencional de água para consumo humano com o objetivo de se saber se, com este tratamento, é possível conseguir concentrações de arsênio remanescentes menores ou iguais ao valor máximo permitido (VMP) estabelecido pela legislação brasileira para a água potável (10 μg/L). Em conjunto, analisou-se o mecanismo de coagulação que impera na(s) região(ões) de maior eficiência de remoção de arsênio. Para desenvolvimento do estudo, trabalhou-se com os coagulantes sulfato de alumínio, policloreto de alumínio (PAC), cloreto férrico e uma mistura de dois destes coagulantes (50% de sulfato de alumínio e 50% de cloreto férrico) em ensaios de bancada para representar as etapas de coagulação/floculação/sedimentação com o Jar Test. Com o intuito de se obter amostras com turbidez alta (≥ 100 uT) e baixa (< 30 uT), coletou-se as águas que foram objeto do estudo em datas diferentes. Foram testadas duas concentrações iniciais de arsênio, 50 e 500 μg/L, seis doses de coagulantes e sete pH iniciais da água bruta, para cada um dos coagulantes usados. O estudo mostrou que, em amostras de água com concentração de arsênio igual ou inferior a 50 μg/L, tanto para turbidez inicial alta quanto baixa, foi possível diminuir a concentração dessa substância para valores inferiores ao VMP. O sulfato de alumínio foi o coagulante com melhor desempenho para águas com turbidez inicial baixa, tendo sido possível identificar três regiões no diagrama de coagulação referentes a diferentes mecanismos de coagulação: região de combinação dos mecanismos de varredura e adsorção, de corona e de varredura. As águas de turbidez alta reagiram melhor à mistura de coagulantes e os mecanismos de coagulação atuantes foram a reestabilização, adsorção-neutralização de cargas e varredura, sendo o arsênio removido por adsorção-coprecipitação nos hidróxidos formados. Em águas com concentração inicial de arsênio de 500 μg/L, apenas o sulfato de alumínio conseguiu atingir o VMP, nas condições de pH igual a 8 e dose de coagulante na faixa de 20 a 25 mg/L. Para águas com turbidez baixa, o mecanismo de coagulação foi a varredura, que possibilita maior formação de hidróxido de alumínio precipitado capaz de remover o ânion arsenato dissolvido por coprecipitação-adsorção. Para águas com turbidez alta, a remoção de As foi elevada (˃98%) quando foram utilizados como coagulantes o cloreto férrico e a mistura, obtendo-se melhores resultados com este último. Os mecanismos de coagulação identificados foram adsorção e varredura. / In this work, arsenic (As) removal in conventional drinking water treatment was evaluated, in order to know if this treatment, it able to achieve residual arsenic concentrations below the maximum contaminant level (MCL) established in the Brazilian drinking water standard (10 μg/L), and analyze the coagulation mechanism that prevails in the regions with the highest efficiency of arsenic removal. To develop the study, the following coagulants were used: aluminum sulphate, polyaluminium chloride, ferric chloride and a 1:1 mixture of aluminum sulphate and ferric chloride in jar tests to represent coagulation/flocculation/sedimentation steps of conventional water treatment. The waters used in this study were collected on different dates, with monthly frequency between August and December of the year 2015 in order to obtain samples with low (less than 30 NTU) and high (higher than or equal to 100 NTU) turbidity. Two initial concentrations of arsenic (50 and 500 μg/L), six coagulant dose (5 to 30 mg/L) and seven initial raw water pH (4 to 8) values were tested for each of the coagulants used. The study showed that it was possible to reduce As concentration below the maximum contaminant level in water samples containing up to 50 μg/L for the coagulants tested regardless of the turbidity. Aluminum sulphate was the best performing coagulant for waters with low turbidity and it was possible to identify three regions in the coagulation diagram obtained, referring to different coagulation mechanisms: combination of adsorption and sweep coagulation region, the corona region and, sweep coagulation. For water with high turbidity, the coagulant mixture was better than the other coagulants and the coagulation mechanisms were: restabilization, adsorption-destabilization and sweep coagulation, with arsenic removed through adsorption and coprecipitation with hydroxide flocs formed. In waters with initial arsenic concentration of 500 μg/L, only aluminum sulphate was able to reach the maximum contaminant level at pH 8 and doses of 20 - 25 mg/L. For low turbidity waters, the coagulation mechanism was the sweep, where there was grater formation of aluminum hydroxide able to remove the dissolved arsenate anion by coprecipitation- adsorption. For water with high turbidity, the removal of arsenic was high (˃ 98 %) when ferric chloride and the mixture were used as coagulants, obtaining better results with the latter. In this case, the coagulation mechanisms identified were adsorption and sweep coagulation.

Page generated in 0.2882 seconds