• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6463
  • 104
  • 102
  • 101
  • 87
  • 78
  • 71
  • 57
  • 29
  • 11
  • 10
  • 10
  • 7
  • 4
  • 4
  • Tagged with
  • 6720
  • 3516
  • 1353
  • 889
  • 877
  • 836
  • 783
  • 730
  • 691
  • 616
  • 596
  • 569
  • 514
  • 473
  • 410
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
591

Qualidade físico-química e microbiológica da água utilizada para consumo humano e dessedentação animal em propriedades rurais produtoras de leite na região do Vale do Taquari/RS

Bortoli, Jaqueline De 22 February 2016 (has links)
Submitted by FERNANDA DA SILVA VON PORSTER (fdsvporster@univates.br) on 2016-07-27T17:30:30Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) 2016JaquelineDeBortoli.pdf: 3041289 bytes, checksum: eb58d96ba4d0be4e8ea2bb19cc841608 (MD5) / Approved for entry into archive by Ana Paula Lisboa Monteiro (monteiro@univates.br) on 2016-08-30T11:45:28Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) 2016JaquelineDeBortoli.pdf: 3041289 bytes, checksum: eb58d96ba4d0be4e8ea2bb19cc841608 (MD5) / Made available in DSpace on 2016-08-30T11:45:28Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) 2016JaquelineDeBortoli.pdf: 3041289 bytes, checksum: eb58d96ba4d0be4e8ea2bb19cc841608 (MD5) Previous issue date: 2016-07 / FAPERGS / A água é um recurso natural finito importante na manutenção da vida, na composição dos seres vivos e do meio ambiente, porém nem sempre é utilizada ou conservada da melhor forma. A utilização da água de poços próprios, fontes, nascentes é uma prática comum no meio rural até por ser considerada pura por quem a consome. Entretanto, muitas vezes, pode haver contaminação física, química ou biológica, seja no processo de captação ou durante o trajeto até o ponto de consumo. Para que a água seja considerada própria para o consumo ela deve atender aos padrões de potabilidade, assegurados pela legislação vigente. O estudo objetivou verificar a qualidade físico-química e microbiológica da água de consumo humano e dessedentação animal em propriedades rurais com produção de leite na região do Vale do Taquari/RS. Esta pesquisa foi composta por 104 estabelecimentos rurais indicados pela Secretaria de Agricultura e EMATER dos 36 Municípios pertencentes à região. Nestes locais foram coletadas amostras de água para análise dos parâmetros físico-químicos: pH, turbidez, cor, condutividade elétrica, temperatura, sólidos dissolvidos totais, alcalinidade, dureza total, amônia, cloro residual livre, cloretos, oxigênio consumido, oxigênio dissolvido e ferro, e dos parâmetros microbiológicos: coliformes totais e termotolerantes. O resultado de cada parâmetro analisado foi comparado ao valor máximo permitido estabelecido (VMP) pelas legislações: Resolução do CONAMA n 396 de 2008 e a Portaria do Ministério da Saúde n o n indicaram que as fontes utilizadas para o abastecimento humano na região são de sociedades de água com tratamento e por poços próprios com e sem tratamento. Os parâmetros físico-químicos cloretos, dureza, ferro e sólidos dissolvidos totais estão de acordo com a legislação em todas das amostras de água analisadas destinada ao abastecimento humano, quando aos parâmetros microbiológicos, os resultados encontraram-se acima do VMP em 62,50% das amostras. Para dessedentação animal a água dos bebedouros provém de poços próprios sem tratamento, seguidas de sociedade de água com tratamento, açudes, arroios, banhados e córregos. Verificou-se que os parâmetros físico-químicos alcalinidade, cloretos, dureza e ferro estão de acordo com o VMP estabelecido pelas legislações e em 50% das amostras os parâmetros microbiológicos encontraram-se acima do VMP. As fontes utilizadas devem aderir ao tratamento simplificado conforme previsto em lei e monitoramento periódico dessas fontes, visando diminuir o número de coliformes e consequentemente atender aos demais parâmetros que ainda não estão enquadrados à legislação. / The water is an important natural finite resource in sustaining life in the composition of living beings and the environment, but it is not always used or preserved in the best way. The use of water from own wells, fountains, springs is a common practice in rural areas to be considered for pure by those who consume. However, often there may be physical, chemical or biological contamination, either in the capture process or on the way to the point of consumption. So that the water is deemed fit for consumption it must meet the potability standards, guaranteed by law. The study aimed to verify the physical-chemical and microbiological quality of drinking water and animal consumption on farms with milk production in the Taquari / RS Valley region. This research consisted of 104 farms listed by the Department of Agriculture and EMATER of 36 municipalities belonging to the region. In these places were water samples for analysis of physico-chemical parameters: pH, turbidity, color, conductivity, temperature, total dissolved solids, alkalinity, total hardness, ammonia, free chlorine, chlorides, consumed oxygen, dissolved oxygen and iron , and microbiological parameters: total and fecal coliforms. The result of each parameter analyzed was compared to the established maximum allowable value (PMV) by the legislation: CONAMA Resolution 357 of 2005 CONAMA Resolution 396 of 2008 and the Ministry of Health Ordinance 2914 in 2011. The results indicated that the sources used for human consumption in the region are water companies with treatment and own wells with and without treatment. The physicochemical parameters chloride, hardness, iron and total dissolved solids are in accordance with the legislation in all the water samples analyzed intended for human consumption, when the microbiological parameters, the results met up VMP in 62.50% samples. For animal consumption water from drinking fountains comes from own wells without treatment, followed by water company with treatment, ponds, streams, wetlands and streams. It has been found that the physico-chemical parameters alkalinity, chloride, iron hardness and X are in accordance with the VMP established by laws and 50% of the samples microbiological parameters found above the VMP. The sources used should adhere to the simplified treatment as provided by law and periodic monitoring of these sources in order to reduce the number of coliforms and consequently meet the other parameters that are not yet classified the legislation.
592

Microalgas como solução para recuperação de nutrientes provenientes de águas negras tratadas /

Slompo, Letícia. January 2018 (has links)
Orientador: Gustavo Henrique Ribeiro da Silva / Coorientadora: Ana Paula Erbetta Sueitt / Banca: Clovis Wesley Oliveira de Souza / Banca: Tânia Vasconcelos Fernandes / Resumo: A recuperação de nutrientes de água negra por meio do crescimento de microalgas é vista como uma solução promissora para o tratamento terciário de águas negras tratadas anaerobicamente, concomitante à recuperação de nutrientes incorporados na biomassa algal para uso como fertilizantes. O objetivo deste trabalho foi avaliar a eficiência de um consórcio de microalgas nativas e um isolado deste consórcio em comparação à C. sorokiniana no tratamento e recuperação de nutrientes de uma água negra tratada por um reator UASB utilizando cultivo aerado com e sem CO2. Na primeira etapa, a água negra tratada anaerobicamente foi colocada em ambiente controlado de luz e temperatura para permitir o crescimento das microalgas existentes. Na segunda e na terceira etapas foi utilizada água negra tratada anaerobicamente em fotobiorreatores em escala laboratorial de dois litros para o crescimento das microalgas durante bateladas de 7 dias. Na segunda etapa foram realizadas três bateladas com o consórcio de microalgas, com iluminação de 40 μmol.m-2.s-1 e cultivo sem e com CO2. Na terceira etapa foram realizadas duas bateladas sem CO2 e duas bateladas com CO2, compostas por fotobiorreatores inoculados com o Consórcio, com o Isolado e com a C. sorokiniana, em triplicata, com iluminação de 120 a150 μmol.m-2.s-1. Nos resultados da Etapa II o cultivo sem CO2 apresentou melhores resultados de peso seco (0,32 g.L-1), de remoção de fósforo inorgânico (84%) e de nitrogênio amoniacal (49%) e resultados sem... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The recovery of black water nutrients through the growth of microalgae has been seen as a promising solution for the tertiary treatment of anaerobically treated black waters, concomitant with the recovery of nutrients incorporated in the algal biomass for use as fertilizers. The objective of this work was to evaluate the efficiency of a consortium of native microalgae and an isolate of this consortium in comparison to C. sorokiniana in the treatment and nutrient recovery of a black water treated by a UASB reactor cultivated with aeration with and without CO2. In the first stage, the black water treated anaerobically was placed in controlled environment of light and temperature to allow the growth of the existing microalgae. In the second and third stages, anaerobically treated black water was used in two-liter laboratory scale photobioreactors for the growth of microalgae during 7-day batches. In the second stage three batchings were carried out with the microalgae consortium, with illumination of 40 μmol.m-2.s-1 and without and with CO2. In the third stage two batch CO2-free and two CO2 batch were performed, using photobioreactors inoculated with the Consortium, Isolate and C. sorokiniana, in triplicate, with illumination of 120 a150 μmol.m-2.s-1. In the results of Step II, the crop without CO2 had better dry weight (0.32 g.L-1), removal of inorganic phosphorus (84%) and ammoniacal nitrogen (49%) and similar results of optical density and cells between cultures without and w... (Complete abstract click electronic access below) / Mestre
593

Aspectos determinantes para o consumo de água de beber

Arrais, Francisca Simone de Souza 27 July 2011 (has links)
Made available in DSpace on 2019-03-29T23:32:20Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-07-27 / A quantidade e a qualidade da água destinada ao consumo humano é, hoje, uma das questões mais críticas para o desenvolvimento sustentável. Em paralelo, nas últimas décadas, constatou-se grande crescimento do mercado de águas engarrafadas, o que ampliou as possibilidades de escolha da água de beber para os consumidores, antes restrita à água de torneira, fornecida ou não pelas companhias de abastecimento regionais. Busca-se, com este trabalho, descobrir os aspectos que determinam a escolha do consumidor. O referencial teórico abrange tópicos sobre seu comportamento, com foco nos aspectos culturais de sua escolha. Foram analisados, ainda, os conceitos de consumo e sustentabilidade. O presente estudo pode ser caracterizado como qualiquantitativo, tendo sido realizados grupos de foco e utilizada a metodologia de análise de discurso na etapa qualitativa. No segmento quantitativo foram aplicados 292 questionários a consumidores de diversas faixas de renda, na cidade de Fortaleza, Ceará, levando-se a efeito análise fatorial e a rotação pelo método Varimax. Os achados apontaram a prevalência das características organolépticas, como determinantes da escolha da água de beber pelos consumidores, seguidas dos aspectos ligados ao tratamento (segurança e adequação) da água. Verificou-se, ainda, que a água engarrafada é vinculada à idéia de adequação, segurança e valor, mesmo que o consumidor desconheça os parâmetros de seu tratamento. Quanto à água de torneira, verificou-se, na amostra pesquisada, desconfiança em relação à sua adequação e segurança, o que parece contribuir para a redução da percepção de seu valor. Este aspecto possui relevante importância no tocante à conservação e sustentabilidade deste recurso. Novos estudos, que possam aprofundar e ampliar os relacionamentos encontrados e suas implicações para o uso sustentável da água de beber, são sugeridos.
594

Detecção de adenovirus, enterovirus e coliformes termotolerantes em amostras de água das praias de Ipanema e do Lami - Porto Alegre - RS / Detection of adenovirus, enterovirus and thermotolerant coliforms in water samples of Ipanema and Lami beaches – Porto alegre – RS

Maurer, Cristiane Piccinini January 2016 (has links)
Doenças infecciosas veiculadas pela água são causa comum de enfermidades em seres humanos no mundo inteiro. Dentre os patógenos causadores destas doenças, os vírus merecem destaque, pois possuem a capacidade de sobreviver em ambientes aquáticos e de permanecer infectantes por meses. A avaliação da balneabilidade das águas brasileiras é monitorada através da densidade de coliformes termotolerantes (CT), classificando as águas de recreação em próprias ou impróprias. Este trabalho tem como objetivo detectar e quantificar genomas de Adenovirus (AdV) e Enterovirus (EV) em amostras de água das praias de Ipanema e do Lami em Porto Alegre – RS e avaliar as condições de balneabilidade através da quantificação de CT. A metodologia utilizada foi reação em cadeia da polimerase em tempo real (qPCR) para os vírus e o método de tubos múltiplos para quantificação de CT. Entre os meses de novembro de 2011 e abril de 2012, foram coletadas 36 amostras de água: 18 amostras de Ipanema e 18 da praia do Lami. Em 30 (83,3%) das 36 amostras coletadas foi detectada a presença de genomas virais. Genoma de AdV foi detectado em 28 (77,8%) amostras, enquanto de EV foi detectado apenas em 8 amostras (22,2%). Em contraste com as baixas concentrações de CT, a pesquisa de AdV e EV demonstrou alta positividade (83,3%), o que demonstra a baixa correlação entre os micro-organismos utilizados como marcadores fecais e a presença de genomas virais em amostras de água. / Waterborne diseases are a common cause of illness in humans worldwide. Among the pathogens causing these diseases, the viruses are noteworthy because they have the ability to survive in aquatic environments and remain infective for months. In Brazil the evaluation of recreational waters is made by monitoring the density of fecal coliform (FC), classifying recreational waters in appropriate or inappropriate. This work aims to detect and quantify genomes of Adenovirus (AdV) and Enterovirus (EV) in water samples from Ipanema and Lami beaches in Porto Alegre - RS and assess the conditions of bathing by quantifying FC. The methodology used was real time polymerase chain reaction (qPCR) for virus and multiple tube technique for FC. Between the months of November 2011 and April 2012 were collected 36 water samples: 18 samples in Ipanema and 18 in Lami. In 30 (83.3%) of the 36 samples the presence of viral genomes was detected. AdV genome was detected in 28 (77.8%) samples, while the EV was only detected in 8 samples (22.2%). In contrast to the low concentrations of FC, research of EV and AdV showed a high positivity (83.3%), which demonstrates the low correlation between micro-organisms used as fecal markers and the presence of viral genomes in water samples.
595

Avaliação hidrogeológica e hidrogeoquímica em área contaminada por manganês na região de Suzano - SP / Not available.

Ishimine, Vinicius 19 April 2002 (has links)
A prática antiga de disposição de resíduos de óxido de manganês em valas sem impermeabilização permitiu a contaminação de solo e água subterrânea por manganês em uma área em Suzano, São Paulo. No local, foram mapeadas duas fontes de contaminação, a principal delas encontra-se enterrada em terreno adjacente à área da indústria, e a secundária, que não foi formada por disposição voluntária de resíduo no solo, encontra-se na área da indústria, como resultado de deposição de material particulado liberado durante o manuseio do produto. Testes de condutividade hidráulica \'in situ\' apresentaram valores de K na ordem de \'10 POT. -7\' m/s. A velocidade da água subterrânea encontra-se no intervalo entre 0,33 e 17,26 cm/dia. Os resultados analíticos nas amostras de água subterrânea indicaram presença de manganês com valores acima dos limites estabelecidos pela Portaria 1469 do Ministério da Saúde na maioria dos poços de monitoramento (Valor Máximo Permitido, 0,10 mg/L), alcançando valores máximos de 6.800 mg/L no primeiro evento de monitoramento (outubro/98) e 4.876 mg/L no segundo (abril/99). Amostras de solo da porção jusante da área indicaram concentrações elevadas de manganês, atingindo valores de até 41.000 mg/Kg. O mapeamento da pluma de contaminação de água subterrânea mostra que ela está inserida em parte do terreno ocupado pela área em estudo e quase que a totalidade da porção jusante a este (área alagadiça). A modelagem hidrogeoquímica realizada através do programa Wateq4f apresentou supersaturação de hidróxido de ferro na maioria das amostras indicando que muitos metais podem estar adsorvidos neste complexo. Muitas amostras indicaram presença de sulfato de manganês, MnS\'O IND. 4 POT. 0\' (aq). Devido às altas concentrações de manganês encontradas em solo e água subterrânea, recomenda-se a execução de ações corretivas, uma vez que o local encontra-se inserido numa Área de Proteção de Mananciais. / The past practice of burying waste of manganese oxide in open, unprepared ditches in an industrial site in Suzano, São Paulo, has originated soil and groundwater contamination. Two sources of contamination were mapped at the site and its neighbourhood. The main source was placed as buried waste on a property adjacent to the industrial área. A second source was originated from dust coming from handling material at the industry. In situ hydraulic conductvty tests indicated K on the order of \'10 IND. -7\' m/s and 17,26 cm/dia. Chemical analyses from groundwater samples indicated manganese concentration above Brazilian standards in most monitoring wells (Portaria 1469 of the Ministerio da Saúde - Valor Máximo Permitido, 0,10 mg/L). The highest manganese concentration were 6.800 mg/L in the first sampling round and 4.876 mg/L in the second. Soil samples from the downgradient portion of the area also indicated high manganese concentrations, with values as high as 41.000 mg/Kg. The mapping of the groundwater contamination plume shows only a small portion of it within the limits of the industry site. Most of plume lies downgradient of the site, in the wetlands. The hydrogeochemical modeling using Wateq4f indicated a supersaturation of iron hydroxide in most groundwater samples, which indicates that many metals might be adsorbed into these complexes. Many samples indicated the presence of manganese sulphate, \'MnSO IND. 4 POT. 0\' (aq). Due to the very high concentration of manganese found in the area, it is recommended a corrective action for soil and groundwater, since the site is located within an Environment Protection Area (Área de Proteção de Mananciais).
596

Estudo das perdas de água no sistema de abastecimento e nas residências do conjunto Benjamim Sodré

VIÉGAS, Alessandro Abadessa 07 August 2009 (has links)
Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2013-03-12T16:42:59Z No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_EstudoPerdasAgua.pdf: 23758453 bytes, checksum: 0e0cd127ce9751e98f1eaeed0af414c2 (MD5) / Approved for entry into archive by Ana Rosa Silva(arosa@ufpa.br) on 2013-03-13T17:33:45Z (GMT) No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_EstudoPerdasAgua.pdf: 23758453 bytes, checksum: 0e0cd127ce9751e98f1eaeed0af414c2 (MD5) / Made available in DSpace on 2013-03-13T17:33:45Z (GMT). No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_EstudoPerdasAgua.pdf: 23758453 bytes, checksum: 0e0cd127ce9751e98f1eaeed0af414c2 (MD5) Previous issue date: 2009 / Neste trabalho é apresentado um estudo das perdas de água no sistema de abastecimento e nas residências do Conjunto Benjamim Sodré. O trabalho foi dividido em duas etapas, sendo a primeira experimental e a segunda de resultados. Posteriormente os dados foram tratados e avaliados e os principais resultados foram: a caracterização e avaliação do cadastro de consumidores, o volume faturado e medido das subcategorias do Conjunto, bem como, as vazões de todo o Sistema de Abastecimento de Água (SAA). Além disso, foram determinados alguns indicadores básicos de desempenho, como índice de perda na distribuição (70,04%), índice de perda no faturamento (70,61%), índice linear bruto de perda (157,96 L/m.dia), índice de perda por ligação (1.446 L/ligação.dia), índice de hidrometração (72,27%) e o Índice Global de Perdas (70,93%). Além disso, foi possível ter o conhecimento do nível sócio-econômico de 30% população residente, das subcategorias R2 e R3 no Conjunto (176 imóveis), onde os resultados mostraram que cerca de 94% dos entrevistados que pagam somente uma taxa para consumo afirmaram praticar desperdícios de água em suas residências. Procurou-se analisar a qualidade da água fornecida a população e cerca de 71,50% dos entrevistados considerou de má qualidade, o que de certa forma pode estar contribuindo com ocorrências de doenças de veiculação hídrica, pois nos últimos anos foi verificado que 24% da população tiveram problemas como diarréias, verminoses, hepatite A e escabiose. Além disso, foi feita uma avaliação do uso da água nas diversas atividades domésticas das subcategorias R2 e R3. Há uma perda de R$ 426,38 ao mês na conta de 15 consumidores que alegaram ter vazamentos na residência. Foi mostrado que para a atividade de lavar louça o consumidor teria uma redução no valor da conta de água de 89,28% em média, para tomar banho 43,66%, lavar roupa na máquina 34,23%, para lavar o pátio ou a calçada 84,80%, e para escovar os dentes 17,06%, referentes as subcategorias R2 e R3. / This work presents a study of water losses in the water supply system of Benjamim Sodré Sector. The work was divided in two steps, as follows: experimental step and results step. Later, data were evaluated and the main results have focused on: characterization and evaluation of the consumers register, revenue and measured water from the down categories of the sector, as well as, the Water Supply System water flows. Besides that, it was made the calculation of some basic performance indicators, such as (index): water loss in the distribution (70,04%), water loss in the revenue (70,61%), water gross loss linear (157,96 L/m.d), connection water loss (1.446,41 L/connection.day), measurement (72,27%) and the global losses (70,93%). Also, it was possible to know the socioeconomic level of the population (30%) of the down categories R2 and R3 of the sector (176 houses), in which the results showed that about 94% of the interviewees who pay only the water bill affirmed to practice waster losses in their houses. The water quality was also analyzed. And it was verified that about 71,50% of the interviewees have considered it bad quality, which may contribute in a important way to the occurrences of Transmissible Hydric Diseases, because it was verified that 24% of the population presented problems concerning to diarrheas, worms, hepatitis A and scabies in the last years. It was made an evaluation of the water uses in the several domestic activities of the down categories R2 and R3. There is a loss of R$ 426,38 per month in the water bill of all consumers that contribute to water leaks in their homes. Finally, it is shown that for the activity of washing the dishes the consumer would have a reduction on the water bill average value of 89,28%. Additionally, to take bath: 43,66%, to wash clothes: 34,23%, to wash the sidewalk: 84,80%, and to brush their teeth 17,06%, referring the down categories R2 and R3.
597

Sistema leito cultivado para tratamento de águas residuárias voltado para o reúso não potável em residências unifamiliares do Distrito Federal

Medeiros, Lídia Batista Pereira 24 July 2018 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Arquitetura e Urbanismo, Programa de Pós-Graduação em Arquitetura e Urbanismo, 2018. / A falta de água é um fator limitante para o desenvolvimento urbano, industrial e agrícola das cidades. O reúso de águas em edificações possui um grande potencial para conservação dos recursos hídricos, quando são considerados os usos não potáveis, pois o custo de tratamento para água não potável é menor, quando se considera altos padrões de qualidade que precisam ser atingidos para obter água potável. Ao considerar uma tecnologia alternativa para tratamento de águas residuárias e produção de água de reúso para usos não potáveis, esta pesquisa analisou o potencial de redução de consumo de água utilizando sistemas leitos cultivados (SLC) em residências unifamiliares de diferentes regiões administrativas (RA), simulando a demanda em dois cenários para usos não potáveis e compondo modelos representativos (MRs) dessas edificações considerando: i) renda familiar; ii) tipologia residencial; iii) presença de área de jardim; e iv) consumo per capita de água. Os MRs compostos foram classificados em MR1: renda alta; MR2: renda média alta; e MR3: renda baixa. O sistema foi composto por fossa séptica para realização do tratamento primário, com remoção de 42% de DBO, leito cultivado de fluxo vertical, com remoção de 43% de DBO e leito cultivado de leito horizontal, com remoção de DBO de 87%. O sistema prevê alcançar concentração de DBO de 30 a 20 mg/L para os usos finais de irrigação, lavagem de pisos e descarga sanitária, em cada um dos cenários. O dimensionamento obtido do SLC obteve a maior área de 10,00 m² para o MR1 no cenário 2 e 6,15 m² para o MR3, no cenário 1. O cenário 2 promoveu maior economia na redução do consumo, chegando a 28%, enquanto que no cenário 1 a maior economia foi de 16%. Através deste estudo pôde-se comprovar que os SLC são uma tecnologia de tratamento de águas residuárias possíveis para serem instalados em residências unifamiliares do DF em 19 regiões administrativas. / The lack of water is a limiting factor for the urban, industrial and agricultural development of cities. The reuse of water in buildings has a great potential for the conservation of water resources, when the non-potable uses are considered, because the cost of treatment for non-potable water is less, when it considers high standards of quality that need to be get clean water. When considering an alternative technology for wastewater treatment and reuse water production for non-potable uses, the present study analyzed the potential of reducing water consumption using wetland constructed (WC) in single family dwellings in different administrative regions (RA), simulating the demand in two scenarios for end-uses non-potable and composing representative models (MRs) of these buildings considering: i) family income; ii) residential typology; iii) presence of garden area; and iv) per capita water consumption. The composite MRs were classified in MR1: high income; MR2: high average income; and MR3: low income. The system was composed of septic tank for primary treatment, with 42% removal of BOD, bed vertical flow bed, with 43% removal of BOD and horizontal bed, with BOD removal of 87%. The system predicts a BOD concentration of 30 to 20 mg/L for the end-uses of irrigation, floor washing and sanitary discharge in each scenario. The SLC obtained the largest area of 10.00 m² for MR1 in scenario 2 and 6.15 m² for MR3, in scenario 1. Scenario 2 promoted a greater saving in consumption, reaching 28%, while that in scenario 1 the largest economy was 16%. Through this study it was possible to prove that the SLC are a technology of wastewater treatment possible to be installed in single-family residences of the DF in 19 administrative regions.
598

Conhecimento dos Trabalhadores do Programa Vigiagua sobre a Fluoretação das Águas de Abastecimento Público

KENUPP, B. Z. 20 March 2017 (has links)
Made available in DSpace on 2018-08-01T23:26:00Z (GMT). No. of bitstreams: 1 tese_10808_DISSERTAÇÃO PÓS DEFESA - BRUNA KENUPP.pdf: 753592 bytes, checksum: b1fa7593c5c09446fcb5b471fda5455e (MD5) Previous issue date: 2017-03-20 / A ação do flúor no controle da cárie dentária por meio das águas de abastecimento público tem sido comprovada mundialmente ao longo dos anos, sendo uma das mais importantes medidas de Saúde Pública e prevenção de doenças de todos os tempos. O controle desta medida no Brasil é realizado pelo Programa Nacional de Vigilância da Qualidade da Água para Consumo Humano (Vigiagua), evitando-se teores do composto abaixo (ausência do benefício) e acima do recomendado (risco de fluorose). O objetivo do estudo foi verificar o conhecimento dos trabalhadores do Programa Vigiagua nos municípios da Grande Vitória, Estado do Espírito Santo, sobre o processo de fluoretação das águas de abastecimento público e seu monitoramento, a importância de se garantir teores adequados de fluoreto na água e o impacto que esses teores têm na saúde da população, bem como discutir a Educação Permanente em Saúde (EPS) como ferramenta para a qualificação desse profissional. Trata-se de uma pesquisa descritiva, de natureza qualitativa, construída por meio de entrevistas com as sete referências técnicas do programa Vigiagua na região da Grande Vitória. Percebeu-se um conhecimento limitado por parte dos trabalhadores sobre a legislação e os objetivos da fluoretação, revelando um trabalho mecanicista com pouco domínio das ações que desenvolvem, além da falha na inserção desses trabalhadores no contexto da EPS. O presente estudo indica a importância do investimento público em recursos humanos, para que se cumpra efetivamente a política de EPS.
599

Monitoramento da qualidade da água de represas e avaliação de riscos aos sistemas de irrigação

FAVERO, D. 23 February 2018 (has links)
Made available in DSpace on 2018-08-01T23:26:42Z (GMT). No. of bitstreams: 1 tese_11850_89_ Daiane Favero.pdf: 1981003 bytes, checksum: 045fd77fd4173aee16f0c84e6a2236b3 (MD5) Previous issue date: 2018-02-23 / A construção de barragens é uma alternativa para aumentar a disponibilidade dos recursos hídricos visando atender as necessidades humanas. No norte do Espírito Santo essa técnica é muito utilizada no armazenamento de água para uso na irrigação, e tem crescido em função dos longos períodos de estiagem. No entanto a quantidade e qualidade das águas dessas barragens podem variar e comprometer seu uso na irrigação. Deste modo, objetivou-se com este trabalho estudar variáveis físico-químicas e hidroquímicas da água em represas recém-construídas, e outras já existentes, no norte do Espírito Santo, para identificação de possíveis riscos aos sistemas de irrigação. O monitoramento foi realizado, ao longo de 14 meses, em 4 represas em Nova Venécia-ES (P1 a P4) e outras 4 represas no município de São Mateus-ES (P5 a P8). As variáveis hidroquímicas analisadas foram pH, temperatura, oxigênio dissolvido (OD), condutividade elétrica (CE), sólidos totais (ST), turbidez, ferro total (FeT), Fe2+, e Fe3+, ortofosfato (PO43-), sulfato (SO43-), sódio (Na+), potássio (K+), cálcio (Ca+), magnésio (Mg2+), dureza, alcalinidade (HCO3-) e cloreto (Cl-). Além disso, dados de nível de água das represas, regime de chuva e evapotranspiração foram obtidos. Os dados foram avaliados através de estatística descritiva (máximo, mínimo, média e desvio padrão), de acordo com a classe de risco de danos ao sistema de irrigação e com os diagramas de Piper e de classificação de águas para irrigação. As elevadas concentrações de ferro e sólidos totais registradas nas águas das represas, tanto de Nova Venécia, quanto de São Mateus, geralmente com maiores valores nas represas novas, inviabilizam o uso direto destas águas na irrigação por gotejamento. Nestes casos, o tratamento da água é indispensável e possibilita seu uso com redução de possíveis danos ao sistema de irrigação, assim os irrigantes devem estar atentos ao uso de filtros, aeradores e decantadores para impedir a passagem destes elementos, impedindo a deposição ao longo do sistema de irrigação. Para os demais parâmetros estudados a maioria das amostras apresentou resultados aceitáveis. As represas de Nova Venécia e São Mateus apresentaram suas águas majoritariamente em classes C1S1, de baixa salinidade e, portanto, de adequada qualidade para irrigação. Poucas amostras foram enquadradas na classe C2S2, em algumas épocas, neste caso essas águas devem ser utilizadas em solos de boa permeabilidade e com certo grau de lixiviação e optar por plantas mais tolerantes. Quanto a classificação hidroquímica das águas de ambos municípios, foram majoritariamente sódicas cloretadas, com pequenas variações composicionais sazonais.
600

Estudos Hidrológicos em microbacias com diferentes usos do solo na sub-bacia do alto Natuba-PE SOLO NA SUB-BACIA DO ALTO NATUBA-PE

ALBUQUERQUE, Felipe Alcântara de 31 January 2010 (has links)
Made available in DSpace on 2014-06-12T17:37:54Z (GMT). No. of bitstreams: 2 arquivo2417_1.pdf: 5327334 bytes, checksum: cbf914b47350683c414565d9c35d5ae0 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2010 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / Resumo: A qualidade e quantidade da água de uma microbacia podem ser influenciadas pelo clima, a cobertura vegetal, a topografia, a geologia, o tipo e o uso do solo na bacia hidrográfica. O objetivo deste estudo foi conhecer o comportamento hidrológico de microbacias em condições diferenciadas de uso do solo, na Zona da Mata de Pernambuco, relacionando estes diferentes tipos de uso do solo em resposta à vazão da microbacia durante os eventos de chuva, e, como esse processo interfere nos padrões de qualidade da água. Foram estabelecidas 3 microbacias experimentais: Natuba 1 de uso e cobertura naturais, Natuba 2 de uso e cobertura mista e Natuba 3 de uso e cobertura antropizada. Foram realizados estudos fisiográficos das microbacias, o levantamento das espécies e estudo de DAP, monitoramento da qualidade da água e estudo de Chuva-Vazão através dos equipamentos de medição hidrometeorológicos. A precipitação observada no período chuvoso superou os valores médios históricos dos postos de monitoramento vizinhos, sendo junho o mês responsável por 34,67% de toda precipitação prevista até o fim de 2010. Tendo como base a resolução CONAMA 357/2005 os parâmetros de qualidade pH, Turbidez, Nitrato, Sólidos totais e coliformes apresentaram condição de Classe Especial nas 3 microbacias. Isso demonstra que esta sub-bacia do rio Natuba não apresenta forte incidência de poluentes. O estudo da vazão específica mostrou que em Natuba 3 observaram-se os maiores valores de vazão em litros por segundo em unidades de Km2 comparando-se às outras microbacias. A partir dos principais eventos de precipitação foi possível se observar que ocorreu uma atenuação dos picos de vazão diretamente proporcional a complexidade vegetacional. Assim como, foi possível observar que áreas com maior cobertura natural ajudaram a regularizar a vazão de forma mais eficiente. Dessa forma fica visível a prestação do serviço ambiental hidrológico por parte da cobertura vegetal, sendo assim, necessário que em áreas prioritárias de produção agrícola haja a máxima conservação florestal, objetivando a preservação do recurso hídrico

Page generated in 0.0358 seconds