• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 814
  • 25
  • 24
  • 24
  • 23
  • 15
  • 14
  • 14
  • 8
  • 7
  • 7
  • 6
  • 2
  • 2
  • 1
  • Tagged with
  • 848
  • 320
  • 276
  • 251
  • 215
  • 202
  • 194
  • 192
  • 189
  • 181
  • 170
  • 164
  • 157
  • 123
  • 107
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Avaliação através do teste de micratração da resistência adesiva em dentina contaminada com saliva humana e sangue fresco

Arouca, Silvio Eduardo [UNESP] 01 March 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:09Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-03-01Bitstream added on 2014-06-13T19:30:41Z : No. of bitstreams: 1 arouca_se_me_arafo.pdf: 3685255 bytes, checksum: 3a12fac77e6217bc7dbb90e3959d7ab5 (MD5) / O objetivo deste trabalho foi realizar, in vitro, avaliação da resistência de união à microtração, sob duas formas de contaminação do substrato dentinário (saliva humana e sangue fresco) e três diferentes formas de limpeza (jato de ar, jato de ar e água e recondicionamento dentinário), utilizando-se do sistema adesivo de 4ª geração, One-Step (Bisco). Foram utilizados 21 terceiros molares humanos íntegros, os quais foram divididos em sete grupos distintos com três dentes cada, sendo um grupo controle e outros seis grupos de trabalho alternando as duas formas de contaminação e as três formas de limpeza. Em cada dente a porção oclusal da coroa foi cortada e sob a superfície plana de dentina foi realizada a contaminação, bem como a limpeza do substrato para que a restauração fosse construída e em seguida os dentes foram submetidos a ciclagem térmica de 1000 ciclos alternando 5º e 55ºC. Os dentes foram cortados em palitos com área de superfície adesiva de 1mm2. Para cada um dos 7 grupos foram realizadas 20 repetições, perfazendo um total de 210 amostras. O teste de resistência a microtração, foi realizado em uma Máquina de Ensaios Mecânicos MTS-810, em velocidade de 1 mm / min, com o auxilio de um dispositivo bipartido onde o palito era fixado com cola Super Bonder gel e o acelerador de presa Zapit. Após a ruptura dos palitos os dados foram compilados através de um programa específicos Test Works 4 e os resultados enviados para a análise estatística. Foi realizada análise de variância para a avaliar estatisticamente os dois agentes contaminantes, combinados com as três formas de limpeza do substrato dentinário em relação à resistência de união à tração. Observou-se que a interação entre os agentes contaminantes e as formas de tratamentos de limpeza da dentina é significativa (valor p<0,0001), então o efeito da contaminação...
32

Avaliação cinesiográfica e da satisfação de usuários de próteses totais após a utilização de dois adesivos

Rodriguez, Larissa Santana [UNESP] 17 December 2014 (has links) (PDF)
Made available in DSpace on 2016-12-09T13:52:22Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-12-17. Added 1 bitstream(s) on 2016-12-09T13:55:27Z : No. of bitstreams: 1 000871149.pdf: 3171374 bytes, checksum: d72bc551442973ddfaca022636b176ce (MD5) / O objetivo deste estudo foi avaliar o efeito da utilização de dois adesivos (AS) (Ultra Corega creme- A1 e Ultra Corega pó - A2) sobre o padrão de movimentos mandibulares, movimentação da prótese total convencional (PT) superior, e o índice de satisfação dos usuários de PT com AS. Material e método: Os participantes (n=40) receberam PT novas e após o período de adaptação, foram submetidos a uma primeira avaliação, e divididos aleatoriamente em dois grupos em função dos protocolos (P): P1- utilização de A1 seguida de utilização de A2; P2 - utilização de A2 seguida de utilização de A1. As variáveis foram obtidas por meio de questionário e cinesiografia. Resultados: Houve uma intrusão semelhante entre controle, A1 e A2 (0,85 mm), porém, um maior deslocamento (0,17 mm) da PT superior após o uso de A2 (p<0,05). Não houve diferença significativa (p>0,05) para o movimento tridimensional da mandíbula após o uso de A1/A2. O conforto e retenção da PT mandibular foram influenciados pelos AS (p< 0,05). A1 e A2 não apresentam diferenças significativas em relação aos seus aspectos (p<0,05), entretanto, quando avaliada a satisfação entre eles, A1 apresentou diferenças significantes em relação a A2 (p<0,05). Conclusão: Embora a utilização de A1 ou A2 não tenha influenciado o movimento tridimensional da mandíbula, foi observado um maior deslocamento da PT superior durante a mastigação com A2. Ambos AS têm influência significativa na satisfação dos pacientes (Resumo completo, clicar acesso eletrônico abaixo) / The objective ofthis studywas toevaluate the effect of using two denture adhesive (DA) (Ultra Corega cream- A1 and Ultra Corega powder - A2) on the pattern of jaw movements, maxillary complete denture (CD) movement, and satisfaction of CD with DA. Methods: Participants (n = 40) received new CD and after the adjustment period, they were submitted an initial assessment, and divided randomly into two groups according to the protocols (P): P1- use A1 followed by use A2; P2 - use A2 followed by use A1. The data were obtained through a questionnaire and kinesiography. Results: There was a similar intrusion of control, A1 and A2 (0.85 mm), but a larger displacement (0.17 mm) from the maxillary CD after use A2 (p <0.05). There was no significant difference (p> 0.05) for the three-dimensional movement of the jaw after using A1 / A2. The comfort and retention of mandibular PT were influenced by AS (p <0.05). A1 and A2 show no significant differences in relation to their aspects (p <0.05), however, when was evaluated the satisfaction between them, A1 showed significant differences from A2 (p <0.05). Conclusion: Although the use of A1 or A2 did not influence the three-dimensional movement of the jaw, a greater displacement of the maxillary CD was observed during chewing with A2. Both DA had significant influence on patient satisfaction, and A1 showed the best results.
33

Efeito do pré-tratamento com laser sobre a resistência de união de sistemas adesivos auto-condicionantes em dentina hipermineralizada artificialmente / Effect of laser pre-treatment on the bond strength of self-etching adhesives on artificially hypermineralized dentin

Leandrin, Thais Pirágine [UNESP] 29 September 2016 (has links)
Submitted by Thais Piragine Leandrin (thaispiragine@hotmail.com) on 2017-06-11T23:36:06Z No. of bitstreams: 1 DISSERTAÇÃO DE MESTRADO .pdf: 595569 bytes, checksum: a3c82c1e07319f17637ff643c2f39039 (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-06-13T14:50:55Z (GMT) No. of bitstreams: 1 leandrin_tp_me_arafo.pdf: 595569 bytes, checksum: a3c82c1e07319f17637ff643c2f39039 (MD5) / Made available in DSpace on 2017-06-13T14:50:55Z (GMT). No. of bitstreams: 1 leandrin_tp_me_arafo.pdf: 595569 bytes, checksum: a3c82c1e07319f17637ff643c2f39039 (MD5) Previous issue date: 2016-09-29 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste trabalho foi avaliar a resistência de união de diferentes sistemas adesivos autocondicionantes, frente a diferentes tratamentos em dentina hipermineralizada artificialmente. Oitenta (N = 80) dentes bovinos foram selecionados e tiveram ampla exposição dentinária. Os grupos foram divididos de acordo com o sistema adesivo autocondicionante de dois passos: AdheSE (Ivoclar) e Clearfil SE Bond (Kuraray). Cada subgrupo recebeu cinco diferentes tratamentos: (1) aplicação do sistema adesivo segundo recomendações do fabricante, (2) condicionamento com ácido fosfórico 37% por 15” + laser Er,Cr:YSGG + adesivo, (3) laser Er,Cr:YSGG + condicionamento com ácido fosfórico 37% por 15” + adesivo, (4) condicionamento com ácido fosfórico 37% + adesivo, (5) aplicação do laser Er,Cr:YSGG + adesivo. Em seguida, cilindros de resina composta (FiltekTM Z350 XT - 3M ESPE) foram posicionados e fotoativados por 40s. Após preparação dos espécimes, parte deles (n=8) ficou armazenada em ambiente úmido a 37°C por 24h para então ser submetida a teste de resistência de união ao microcisalhamento. Os resultados de resistência de união foram obtidos em MPa e submetidos à Análise de Variância e Teste de Tukey ao nível de significância de 5%. Os resultados demonstram que o grupo tratado com ácido + adesivo, utilizando o sistema AdheSE apresentou os maiores valores médios de resistência de união ao microcisalhamento. Pode-se concluir que o pré-tratamento a laser não interferiu negativamente nos valores de resistência de união dos sistemas adesivos autocondicionantes em dentina hipermineralizada artificialmente. / The objective of this study was to evaluate the bond strength of different adhesive systems after different treatments of normal and artificially hypermineralized dentin. Eighty (N=100) healthy bovine teeth had been selected and will have extensive dentin exposure. The groups were divided according to the adhesive system used: AdheSE and Clearfil SE Bond. Each subgroup received five different treatments: (1) applying the adhesive system following manufacturer's recommendations, (2) etching with 37% phosphoric acid for 15 " + Er, Cr: YSGG laser + adhesive, (3) Er, Cr: YSGG laser + etching with 37% phosphoric acid for 15 " + adhesive, (4) etching with 37% phosphoric acid + adhesive, (5) Er,Cr: YSGG laser + adhesive. Cylinders of composite resin (Z350 XT FiltekTM - 3M ESPE) were positioned and photoactivated for 40s. After a period of storage in a humid environment for 24 hours at 37°C, the specimens were submitted to the microshear bond strength test. Differences between groups were determined using ANOVA and Tukey’s statistical tests at a significance level of 5%. The results showed that the group treated with acid + adhesive using the AdheSE system provided the highest values of microshear bond strength. It can be concluded that laser pretreatment did not affect negatively the bond strength of the self-etching adhesive systems on artificially hypermineralized dentin.
34

Estudo comparativo entre dois adesivos no desempenho mastigatório de usuários de próteses totais /

Oliveira Junior, Norberto Martins de. January 2014 (has links)
Orientador: Marco Antonio Compagnoni / Banca: Ana Carolina Pero / Banca: Karin Hemana Neppelenbroek / Resumo: Proposição: O objetivo deste estudo foi avaliar o efeito da utilização de dois adesivos para prótese em relação ao desempenho mastigatório de usuários de próteses totais convencionais, por meio de um estudo "cross-over". Material e Método: Cinquenta indivíduos totalmente desdentados receberam novas próteses totais bimaxilares e, após o período de adaptação posterior à instalação, foram submetidos à análise do desempenho mastigatório com as próteses sem adesivos protéticos (controle). Posteriormente, a amostra foi dividida aleatoriamente e designada a dois protocolos, nos quais a ordem de uso dos adesivos era diferente. Os adesivos Ultra Corega creme e Ultra Corega pó foram utilizados por 15 dias previamente à aplicação de novas análises do desempenho mastigatório, por toda a amostra, e respeitando-se um período de descanso (washout), também de 15 dias, entre o uso de cada adesivo. O desempenho mastigatório foi avaliado pelo método dos tamises. Os dados obtidos foram submetidos ao teste não-paramétrico de Friedman e comparação múltipla de média de ordens utilizando o teste de DUNN (α=0,05). Resultados: Houve aumento significativo do desempenho mastigatório após uso dos adesivos Ultra Corega creme (med=27,4%) e Ultra Corega pó (med=28,0%), quando estes foram comparados ao grupo controle (med=16,5%) (p<0,001; n=30), não havendo diferença estatisticamente significante entre os adesivos testados (p=0,897; n=30). Conclusões: O uso de adesivos aumentou o desempenho mastigatório de usuários de próteses totais convencionais, e não houve diferença para o desempenho mastigatório quanto ao uso de adesivos nas formas de creme e pó. / Abstract: Objective: The objective of this study was evaluate the effect of use of two denture adhesives in relation to masticatory performance of conventional complete denture wearers, by means of a cross-over study. Material and Method: Fifty edentulous individuals received new bimaxillary complete dentures and, after the adaptation period, were submitted to masticatory performance analysis with complete dentures without adhesives (control). So, the sample was randomly divided and assigned to two protocols, in which the adhesives order of use was different. The adhesives Ultra Corega cream and Ultra Corega powder were used for 15 days prior the application of new masticatory performance analysis, by all the sample, and respecting a washout period, also 15 days, between the use of each adhesive. The masticatory performance was evaluated by sieves method. Data were analyzed by nonparametric Friedman test and multiple comparison of average orders using test DUNN (α=.05). Results: There was significant increase in masticatory performance after use of adhesives Ultra Corega cream (med=27.4%) and Ultra Corega powder (med=28.0%), when these were compared to the control group (med=16.5%) (p<.001; n=30), without statistically significant difference between the tested adhesives (p=0,897; n=30). Conclusions: The use of adhesives increased masticatory performance of conventional complete denture wearers, and there was no difference for masticatory performance as the use of adhesives in the forms of cream and powder. / Mestre
35

Resistência de união ao microcisalhamento de sistemas adesivos autocondicionates com graus de acidez distintos : efeito de diferentes tratamentos em substrato dentinário normal e hipermineralizado artificialmente/

Piccioni, Máyra Andressa Rodrigues Valinhos. January 2014 (has links)
Orientador: José Roberto Cury Saad / Banca: Edson Alves de Campos / Banca: Marcelo Ferrarezi de Andrade / Banca: Cristina Magnani Felício / Banca: Patricia Aleixo dos Santos / Resumo: O objetivo deste trabalho, dividido em três estudos: foi avaliar a resistência de união de diferentes sistemas adesivos autocondicionantes, com graus de acidez distintos, frente a diferentes tratamentos dentinários: condicionamento ácido, laser e ponta diamantada em dentina normal e hipermineralizada artificialmente. No primeiro estudo, foi realizada uma busca na literatura sobre o uso do laser Er;Cr:YSGG na Odontologia Restauradora. Nos segundo e terceiro, duzentos e vinte e quatro (n = 224) molares humanos hígidos foram selecionados. Os dentes tiveram seu terço oclusal seccionado com o objetivo de expor superfície dentinária plana e foram lixados para a exposição de uma superfície dentinária uniforme e "padronizada". Os espécimes foram divididos aleatoriamente em dois diferentes grupos, de acordo com o tipo de dentina: normal (N/n=108) e hipermineralizada artificialmente (H/ n=116). O grupo H recebeu tratamento para hipermineralização e oito dentes foram selecionados aleatoriamente e observados em MEV para a confirmação do procedimento de hipermineralização. Os dentes de cada grupo foram divididos aleatoriamente em quatro diferentes subgrupos, de acordo com o sistema adesivo autocondicionante empregado: Clearfil S3 Bond e Optibond All in One - Passo único - (Artigo 2); Clearfil SE Bond e Adhese - Dois Passos - (Artigo 3). Cada subgrupo (n=9) recebeu diferentes tratamentos: (1) condicionamento convencional: aplicação do sistema adesivo autocondicionante segundo recomendações do fabricante; (2) condicionamento da superfície dentinária com laser Er,Cr:YSGG (Waterlase Millennium, Biolaser Technology, San Clement, CA, USA) + aplicação do sistema adesivo segundo recomendações do fabricante; (3) "asperização" da superfície dentinária com ponta diamantada 3098 + aplicação do sistema adesivo segundo recomendações do fabricante. Em seguida, matrizes transparentes... / Abstract: The aim this work, divided in three studies, was evaluate the bond strength of different adhesive systems with different degrees of acidity, to different dentinal treatments: acid etching, laser and diamond bur in normal dentin and artificially hypermineralized dentin. In the first study, it was performed a literature review on the use of the Er,Cr : YSGG in Restorative Dentistry. In the second and third, two hundred twenty-four (n = 224) human molars were selected. The teeth had their third occlusal sectioned in order to expose flat dentin surface and it were ground to expose dentin surface uniform, " standardized". The specimens were randomly divided into two groups according to the type of dentin normal (N /n = 108) and artificially hypermineralized (H / n = 116) . The group H received treatment for hypermineralization and eight teeth were randomly selected and observed by SEM to confirm the hypermineralization procedure. The teeth of each group were randomly divided into four different subgroups, according to the adhesive system used: Clearfil S3 Bond and Optibond All in One - One step- (Article 2 ); Clearfil SE Bond and AdheSE - Two steps - (Article 3). Each subgroup (n = 9) received different treatments: (1) conventional conditioning : application of the adhesive system according to the manufacturer's recommendations, (2) conditioning of the dentin surface with Er,Cr:YSGG laser (Waterlase Millennium Biolaser Technology, San Clement, CA, USA) + adhesive system according to the recommendations of the manufacturer, (3) " roughening " of the dentin surface with a diamond tip 3098 + adhesive system according to the recommendations of the manufacturer. Then, cylindrical transparent molds were placed on the dentin surface treated with the adhesives and were filled with composite resin (Z350 XT FiltekTM - 3M ESPE) and light-cured for 40s. The molds were removed to expose the composite resin cylind... / Doutor
36

Influência da smear layer e da condição de tratamento da dentina (in vivo e in vitro), sobre a resistência de união /

Kina, João Fernando. January 2004 (has links)
Orientador: Carlos Alberto de Souza Costa / Banca: José Roberto Cury Saad / Banca: Marcelo Giannini / Resumo: O objetivo da presente pesquisa foi avaliar comparativamente, a influência da smear layer e da condição de tratamento da dentina (in vivo e in vitro), sobre a resistência de união entre um sistema adesivo auto-condicionante e o substrato dentinário. Para isto, foram realizados preparos cavitários de classe I em 20 primeiros pré-molares superiores humanos, com profundidade média de 2,5mm. Todos os dentes foram restaurados com resina composta Z250, cor A3 (3M ESPE), utilizando-se do sistema adesivo auto-condicionante Clearfil SE Bond (Kuraray Co. Ltda). As amostras foram divididas em 4 grupos experimentais: G1 - in vivo, com remoção da smear layer; G2 - in vivo, sem remoção da smear layer; G3 - in vitro, com remoção da smear layer e G4 - in vitro, sem remoção da smear layer. Para os grupos 1 e 2 (in vivo), os procedimentos operatórios foram realizados com o dente na cavidade bucal dos pacientes, sendo que para os grupos 3 e 4 (in vitro), estes procedimentos foram realizados após extração dos dentes, em laboratório. O agente condicionador EDTA 0,5M pH 7,2, foi utilizado para remoção da smear layer. Os dentes foram mantidos em solução de glutaraldeído a 2,5% por período máximo de 5 dias, sendo posteriormente cortados de tal forma a obter, em média, 8 "palitos" por dente (21 "palitos" para cada grupo experimental e controle). Cada espécime ("palito") foi individualmente submetido ao teste de microtração e os valores de resistência de união expressos em MPa. A análise estatística de ANOVA, complementada pelos testes de Levene, Kolmogorov-Smirnov e Pearson, foi aplicada aos dados numéricos obtidos. Os resultados mostraram que tanto in vivo como in vitro, a resistência de união média foi estatisticamente maior, quando se realizou a remoção da smear layer... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The aim of this investigation was to evaluate and to compare the influence of the smear layer and the dentin treatment (in vivo and in vitro) on bond strength of a self etching bonding system to dentin. Class I cavities with 2,5mm depth were performed in 20 sound human premolars. Following application of the self etching adhesive system Clearfil SE Bond (Kuraray Co.Ltd.), all teeth were restored using Z 250 composite resin (3M ESPE). The teeth were randomly assigned to 4 experimental groups: G1 - in vivo, with smear layer removal; G2 - in vivo, with maintenance of smear layer; G3 - in vitro, with smear layer removal and G4 - in vitro, with maintenance of smear layer. In groups 1 and 2 (in vivo), the clinical procedures were performed before surgical extraction. On the other hand, in groups 3 and 4 (in vitro), the clinical procedures were performed after extraction, in the laboratory. The 17% EDTA conditioning agent (0,5M / pH7.2) was used to remove smear layer. The samples were stored in 2.5% glutaraldehyde solution for about 5 days, then sectioned into 0,7mm thick slabs. Each slab was finally trimmed for the micro-tensile bond test. It was obtained 8 trimmed specimens by every tooth (21 trimmed specimens for each experimental and control groups). The data of micro-tensile bond test (MPa) were submitted to the statistical analysis of ANOVA complemented by Levene, Kolmogorov-Smirnov, and Pearson tests. It was not demonstrated statistical differences when the mean values of the tensile bond strength (MPa) were compared between the both in vivo and in vitro groups. However, even when better results were observed for in vitro groups the differences were not statistically significant of those determined for in vivo groups. In addition, no correlation between bond strength and dentin thickness (p=0,830) was observed. In conclusion, the results of this investigation demonstrated no difference... (Complete abstract, click electronic address below). / Mestre
37

Avaliação através do teste de micratração da resistência adesiva em dentina contaminada com saliva humana e sangue fresco /

Arouca, Silvio Eduardo. January 2004 (has links)
Orientador: Marcelo Ferrarezi de Andrade / Banca: José Roberto Cury Saad / Banca: Mânio de Carvalho Tibúrcio / Resumo: O objetivo deste trabalho foi realizar, in vitro, avaliação da resistência de união à microtração, sob duas formas de contaminação do substrato dentinário (saliva humana e sangue fresco) e três diferentes formas de limpeza (jato de ar, jato de ar e água e recondicionamento dentinário), utilizando-se do sistema adesivo de 4ª geração, One-Step (Bisco). Foram utilizados 21 terceiros molares humanos íntegros, os quais foram divididos em sete grupos distintos com três dentes cada, sendo um grupo controle e outros seis grupos de trabalho alternando as duas formas de contaminação e as três formas de limpeza. Em cada dente a porção oclusal da coroa foi cortada e sob a superfície plana de dentina foi realizada a contaminação, bem como a limpeza do substrato para que a restauração fosse construída e em seguida os dentes foram submetidos a ciclagem térmica de 1000 ciclos alternando 5º e 55ºC. Os dentes foram cortados em palitos com área de superfície adesiva de 1mm2. Para cada um dos 7 grupos foram realizadas 20 repetições, perfazendo um total de 210 amostras. O teste de resistência a microtração, foi realizado em uma Máquina de Ensaios Mecânicos MTS-810, em velocidade de 1 mm / min, com o auxilio de um dispositivo bipartido onde o palito era fixado com cola Super Bonder gel e o acelerador de presa Zapit. Após a ruptura dos palitos os dados foram compilados através de um programa específicos Test Works 4 e os resultados enviados para a análise estatística. Foi realizada análise de variância para a avaliar estatisticamente os dois agentes contaminantes, combinados com as três formas de limpeza do substrato dentinário em relação à resistência de união à tração. Observou-se que a interação entre os agentes contaminantes e as formas de tratamentos de limpeza da dentina é significativa (valor p<0,0001), então o efeito da contaminação... (Resumo completo, clicar acesso eletrônico abaixo) / Mestre
38

Avaliação de aspectos relacionados á utilização de um adesivo para próteses totais convencionas: estudo in vitro /

Leite, Andressa Rosa Perin. January 2013 (has links)
Orientador: Ana Carolina Pero / Banca: Marco Antonio Compagnoni / Banca: Raphael Freitas de Souza / Resumo: O objetivo do presente estudo foi avaliar a influência da utilização de um adesivo para prótese (Ultra Corega creme) na formação de biofilme sobre a superfície interna de próteses totais e na microbiota bucal, no grau de satisfação, além da estimativa de custo médio diário do produto. Trinta pacientes receberam próteses totais novas, e foram divididos em dois protocolos: protocolo 1- utilização do adesivo durante os primeiros 15 dias de teste, seguida por não utilização de nenhum tipo de adesivo durante os próximos 15 dias; protocolo 2- não utilização de adesivo durante os primeiros 15 dias de teste, seguida por utilização do adesivo durante os próximos 15 dias. Após cada período de 15 dias, o biofilme formado na superfície interna das próteses totais foi corado e quantificado por meio de um método fotográfico com o auxílio de um software (Image Tool 3.00). Amostras de material da mucosa palatina e da superfície interna das próteses superiores foram plaqueadas em meios seletivos para Candida spp. e Streptococcus mutans e em um meio não seletivo. Ainda, foi aplicado um questionário para avaliação da satisfação com as próteses e o custo médio diário do produto foi estimado por meio de fórmulas matemáticas. Todas as análises foram realizadas com α = 0,05 e foram empregados testes apropriados à distribuição dos dados. Foi observada formação de biofilme semelhante com ou sem o uso do adesivo sobre as próteses superiores (Wilcoxon, p=0,255) e inferiores (Wilcoxon, p=0,433). Contagens de colônias semelhantes foram observadas com ou sem a utilização do adesivo na mucosa e na superfície interna da prótese total superior (p>0,05). O uso de adesivo proporcionou maior satisfação aos participantes (Wilcoxon, p=0,04). Em média, cada paciente utilizou 3,9 ± 0,3 gramas de adesivo por dia... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate the influence of adhesive usage (Ultra Corega cream) on biofilm formation on the internal surface of dentures and oral microbiota, degree of satisfaction, and the estimated average daily cost of product. Thirty patients received new dentures, and have been divided into two protocols: Protocol 1-use of the adhesive during the first 15 days of the test, followed by not using adhesive over the next 15 days; Protocol 2- no use of adhesive for the first 15 days of the test, followed by use of adhesive over the next 15 days. After each period of 15 days, the internal surfaces of the dentures were stained and photographed and the areas (total internal surface and surface stained with biofilm) quantified (Image Tool 3.00). Samples of material from the palatal mucosa and the internal surface of the maxillary denture were plated on selective media for Candida spp. and Streptococcus mutans and a non-selective medium. A questionnaire was applied to evaluate satisfaction with the dentures and the average daily cost of the product was estimated by mathematical formulas. All analyzes were performed with α=.05 and appropriate tests were applied to the data distribution. Similar biofilm formation was found with or without adhesive usage for maxillary (Wilcoxon, p=.255) and mandibular dentures (Wilcoxon, p=.433). Similar colony counts were observed with or without adhesive for mucosa and the internal surface of dentures, irrespective of the culture medium (p>.05). The use of adhesive provided higher satisfaction (Wilcoxon, p=.04). On average, each patient used 3.9 ± 0.3 grams of adhesive per day, equivalent to R $ 4.02 for average daily cost. It is concluded that the use of the adhesive did not affect the quantification of the biofilm and the oral microbiota, besides providing greater overall satisfaction / Doutor
39

Síntese e caracterização de poliamida termofundível

Freitas, Renata Fialho Rocha January 2012 (has links)
Made available in DSpace on 2013-08-07T18:54:02Z (GMT). No. of bitstreams: 1 000441029-Texto+Parcial-0.pdf: 250230 bytes, checksum: 40a27c9638305e87ec4b7d6e314ec579 (MD5) Previous issue date: 2012 / Hot melt adhesives have the advantage that don’t release volatile organic compounds as solvent-based adhesives. Polyamides containing dimer fatty acid in their structure can be used as hot melt adhesives. In this work polyamides with different compositions of dimer fatty acid, primary amines and secondary amines and their proportions were synthesized, the effect of these changes were evaluated in physical, chemical and mechanical properties. In relation to primary amines, ethylenediamine and hexamethylenediamine were used and it was found that a smaller chain gives an increase in the softening point, a higher elongation, lower Tg and a higher crystallization. The variation of secondary amines (DIPIP, piperazine, and aminoethylpiperazine) didn’t affect the softening point. The piperazine based polyamide promotes better crystallization compared to the other structures of the amines (DIPIP and aminoethylpiperazine), because piperazine can promote higher organization of the chains. The methylenes groups from DIPIP and aminoethylpiperazine provide higher elongation of polyamides, increasing mobility of the chains. Increasing the content of ethylenediamine provides increased intermolecular interactions, giving a rise in the softening point, crystallization, viscosity and mechanical strength of the polyamide. Different compositions of dimer fatty acids were evaluated and was observed that the higher content of monomers, the lower molecular weight of the polyamide were achieved, consequently lower viscosity and more brittle polymers. Higher purity of dimer fatty acid promotes the formation of only one fraction of crystallization and melting. Performance bonding is usually associated by molecular weight of the polyamide and intermolecular interactions between substrate and polyamide chains. / Os adesivos termofundíveis apresentam a vantagem de não liberarem compostos orgânicos voláteis (COVs), como no caso dos adesivos base solvente. Poliamidas contendo ácido graxo dimerizado em sua estrutura podem ser utilizadas como adesivos termofundíveis. Neste trabalho foram sintetizadas poliamidas com diferentes composições de ácido graxo dimerizado, aminas primárias e aminas secundárias e suas proporções e foi avaliado o efeito destas modificações nas propriedades físicas, químicas e mecânicas. Em relação às aminas primárias, foi utilizado a etilenodiamina e hexametilenodiamina e verificou-se que uma cadeia menor confere um aumento no ponto de amolecimento, um maior alongamento, maior cristalização e uma Tg menor. A variação das aminas secundárias (DIPIP, piperazina e aminoetilpiperazina) não afetaram significativamente o ponto de amolecimento. A piperazina promoveu a poliamida uma maior cristalização, comparado com as demais estruturas das aminas (DIPIP e aminoetilpiperazina), pois favorece uma maior organização das cadeias. Os grupamentos metilenos das aminas DIPIP e aminoetilpiperazina proporcionaram um maior alongamento às poliamidas, aumentando a mobilidade das cadeias. O aumento do teor de etilenodiamina proporcionou o aumento das interações intermoleculares, causando o aumento do ponto de amolecim ento, cristalização, viscosidade e resistência mecânica da poliamida. Ácidos graxos dimerizados com diferentes composições também foram avaliados e, verificou-se que quanto maior o teor de monômeros, menor é a massa molecular da poliamida e, conseqüentemente, com menor viscosidade e mais quebradiça. A maior pureza do ácido graxo dimerizado promove a formação de uma fração única de cristalização e fusão. A adesão da poliamida, em geral, está associada mais à massa molecular da poliamida e as interações intermoleculares entre substrato e cadeias da poliamida.
40

Desenvolvimento de adesivos de poliuretano a base de óleo de mamona

Silva, Bianca Bairros Rabello da January 2006 (has links)
Neste trabalho foram desenvolvidos adesivos de poliuretano a base de óleo de mamona e tolueno diisocianato (TDI), livre de solvente com o objetivo de obter produtos ecologicamente corretos a partir de matéria-prima de fonte renovável e avaliar seu desempenho adesivo em substratos de espuma flexível e madeira. Adesivos com razões molares NCO/OH iguais a 1, 2, 3 e 4 e diferentes teores de catalisadores foram preparados. Os catalisadores utilizados foram Dibutildilaurato de Estanho (DBTL), em quantidades de 0,8 ou 1% em massa, e Trietilenodiamina (TEDA), nas concentrações em massa de 0,14 e 0,18%, obtendo-se uma relação molar 1:1 entre DBTL/TEDA. A reação de cura foi acompanhada por FTIR. Os adesivos desenvolvidos foram caracterizados por TGA, DSC, tempo de tack-free, ensaios mecânicos de tração dos filmes adesivos e testes de dureza. O poder adesivo foi avaliado através de ensaio de resistência ao descascamento, para substrato de espuma flexível e resistência ao cisalhamento para o substrato de madeira. Os resultados obtidos são promissores, pois foi possível atingir valores até 75% superiores aos adesivos comerciais em resistência ao descascamento e 19% superiores em tensão de cisalhamento. / In this work were development solvent-free bi-component polyurethane (PU) adhesives based on castor oil and Toluene Diisocyanate (TDI), to obtain ecological products by raw material renewable source, and to study their adhesive behavior on PU flexible foam and wood substrates. Adhesives were synthesized with NCO/OH molar ratio of 1, 2, 3 and 4 and different catalysts ratio. The catalysts used were Dibutyltin dilaurate (DBTL), in 0,8 or 1% (w/w), and Triethylenediamine (TEDA), in 0,14 or 0,18% (w/w), obtaining molar ratio DBTL:TEDA of 1:1. The cure reaction was following by FTIR spectroscopy. The PU adhesives were characterized by thermogravimetric analysis (TGA), differential scanning calorimeter (DSC), tack-free time, mechanical testing and hardness measurements. The adhesion was evaluated by peel-test, to flexible foam substrate, and by lap shear test, to wood substrate. The obtained results are promising, in that the adhesion strength of the developed PU adhesives have reached values 75% higher than the commercial foam adhesive for foam substrates and 19% higher than the wood commercial adhesive for wood substrates.

Page generated in 0.34 seconds