• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 814
  • 25
  • 24
  • 24
  • 23
  • 15
  • 14
  • 14
  • 8
  • 7
  • 7
  • 6
  • 2
  • 2
  • 1
  • Tagged with
  • 848
  • 320
  • 276
  • 251
  • 215
  • 202
  • 194
  • 192
  • 189
  • 181
  • 170
  • 164
  • 157
  • 123
  • 107
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação de aspectos relacionados á utilização de um adesivo para próteses totais convencionas: estudo in vitro

Leite, Andressa Rosa Perin [UNESP] 13 March 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:56Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-03-13Bitstream added on 2014-06-13T18:58:08Z : No. of bitstreams: 1 leite_arp_me_arafo.pdf: 1273945 bytes, checksum: cb5883147f849ba467e943f22b736489 (MD5) / O objetivo do presente estudo foi avaliar a influência da utilização de um adesivo para prótese (Ultra Corega creme) na formação de biofilme sobre a superfície interna de próteses totais e na microbiota bucal, no grau de satisfação, além da estimativa de custo médio diário do produto. Trinta pacientes receberam próteses totais novas, e foram divididos em dois protocolos: protocolo 1- utilização do adesivo durante os primeiros 15 dias de teste, seguida por não utilização de nenhum tipo de adesivo durante os próximos 15 dias; protocolo 2- não utilização de adesivo durante os primeiros 15 dias de teste, seguida por utilização do adesivo durante os próximos 15 dias. Após cada período de 15 dias, o biofilme formado na superfície interna das próteses totais foi corado e quantificado por meio de um método fotográfico com o auxílio de um software (Image Tool 3.00). Amostras de material da mucosa palatina e da superfície interna das próteses superiores foram plaqueadas em meios seletivos para Candida spp. e Streptococcus mutans e em um meio não seletivo. Ainda, foi aplicado um questionário para avaliação da satisfação com as próteses e o custo médio diário do produto foi estimado por meio de fórmulas matemáticas. Todas as análises foram realizadas com α = 0,05 e foram empregados testes apropriados à distribuição dos dados. Foi observada formação de biofilme semelhante com ou sem o uso do adesivo sobre as próteses superiores (Wilcoxon, p=0,255) e inferiores (Wilcoxon, p=0,433). Contagens de colônias semelhantes foram observadas com ou sem a utilização do adesivo na mucosa e na superfície interna da prótese total superior (p>0,05). O uso de adesivo proporcionou maior satisfação aos participantes (Wilcoxon, p=0,04). Em média, cada paciente utilizou 3,9 ± 0,3 gramas de adesivo por dia... / The aim of this study was to evaluate the influence of adhesive usage (Ultra Corega cream) on biofilm formation on the internal surface of dentures and oral microbiota, degree of satisfaction, and the estimated average daily cost of product. Thirty patients received new dentures, and have been divided into two protocols: Protocol 1-use of the adhesive during the first 15 days of the test, followed by not using adhesive over the next 15 days; Protocol 2- no use of adhesive for the first 15 days of the test, followed by use of adhesive over the next 15 days. After each period of 15 days, the internal surfaces of the dentures were stained and photographed and the areas (total internal surface and surface stained with biofilm) quantified (Image Tool 3.00). Samples of material from the palatal mucosa and the internal surface of the maxillary denture were plated on selective media for Candida spp. and Streptococcus mutans and a non-selective medium. A questionnaire was applied to evaluate satisfaction with the dentures and the average daily cost of the product was estimated by mathematical formulas. All analyzes were performed with α=.05 and appropriate tests were applied to the data distribution. Similar biofilm formation was found with or without adhesive usage for maxillary (Wilcoxon, p=.255) and mandibular dentures (Wilcoxon, p=.433). Similar colony counts were observed with or without adhesive for mucosa and the internal surface of dentures, irrespective of the culture medium (p>.05). The use of adhesive provided higher satisfaction (Wilcoxon, p=.04). On average, each patient used 3.9 ± 0.3 grams of adhesive per day, equivalent to R $ 4.02 for average daily cost. It is concluded that the use of the adhesive did not affect the quantification of the biofilm and the oral microbiota, besides providing greater overall satisfaction
12

Desenvolvimento de adesivos nanocompósitos de poliuretano à base de óleo de mamona

Marques, Jeanne Letícia da Silva January 2009 (has links)
Os nanomateriais têm sido cada vez mais estudados e utilizados em aplicações para diversos segmentos. Neste trabalho foram desenvolvidos adesivos nanocompósitos de poliuretano a partir de óleo de mamona e montmorilonita organicamente modificada (OMMT) com o objetivo de se avaliar o efeito da nanocarga no desempenho dos adesivos de PU. Sabe-se que nanocargas do tipo modificada, para serem efetivas no meio em que se encontram ou modificar uma propriedade, devem se encontrar finamente dispersas. Assim, neste trabalho foram avaliadas rotas de preparação ou formas de inchamento diferenciadas da nanocarga em poliol (óleo de mamona) e em diisocianato (MDI), na presença de solvente ou não, com possibilidade de haver graftização do MDI na nanocarga. A OMMT antes e após inchamento foi caracterizada por espectroscopia de infravermelho (FTIR), análise termogravimétrica (TGA) e difração de raios-x (DRX). Os adesivos de PU/OMMT foram caracterizados por FTIR, tempo de tack-free, dureza, TGA, calorimetria diferencial de varredura, análise dinâmico-mecânica (DMA) e tração (filmes), DRX e microscopia eletrônica de varredura. A ocorrência da reação entre os grupos NCO do isocianato e do OH da OMMT foi evidenciada através de análises de infravermelho, termogravimétricas e morfológicas, confirmando a graftização da OMMT pelo MDI. Dependendo da forma de preparação pôde se observar homogeneidade com relação à dispersão das nanopartículas na matriz polimérica; e a estabilidade térmica em geral dos adesivos nanocompósitos foi superior. O tempo de tack-free diminuiu com o aumento da concentração da nanoargila. A performance dos adesivos nanocompósitos nos testes de resistência da colagem (tensão de cisalhamento) foram razoáveis, porém inferiores aos adesivos comerciais. Resultados comparativos entre os adesivos de PU com e sem nanocarga, mostraram que a OMMT modificou o comportamento mecânico dos adesivos nanocompósitos, com melhoria das propriedades de tração e dureza. / Nanomaterials have been studied and used in several applications, in different segments. In this work adhesives of polyurethane (PU) consisting of castor oil and organic modified montmorillonite nanoclay (OMMT) were obtained with the objective of evaluating the effect of the nanoclay in these adhesives. The adhesives were prepared by swelling the nanofiller, in the castor oil and in the MDI. In the latter the nanoclay was previously treated or not with solvent. The OMMT swelling was characterized using infrared spectroscopy (FTIR), thermogravimetric analysis (TGA) and X-ray diffraction (XRD). The adhesives were characterized by FTIR, tack-free time, hardness, TGA, differential scanning calorimetry (DSC), dynamic mechanical analysis (DMA), physical and mechanical analysis, XRD and scanning electronic microscopy (SEM). The reaction between NCO groups and OH groups of the OMMT was evidenced by FTIR, TGA and XRD. Depending on the preparation route the nanoclay homogeneously dispersed could be observed in the polymer matrix, and the thermal stability of the nanocomposites adhesives was in general higher than the ones without nanoclay. The tack-free time of the adhesives decreased as higher the nanoclay concentration. The shear strength of the nanocomposites adhesives in bonding resistance tests was reasonable, although it has been lower than the values showed by commercial adhesives. Comparing the PU adhesives with and without nanoclay it could be stated that OMMT modified the mechanical behavior of the nanocomposites adhesives, improving tensile properties and hardness.
13

Desenvolvimento de adesivos de poliuretano a base de óleo de mamona

Silva, Bianca Bairros Rabello da January 2006 (has links)
Neste trabalho foram desenvolvidos adesivos de poliuretano a base de óleo de mamona e tolueno diisocianato (TDI), livre de solvente com o objetivo de obter produtos ecologicamente corretos a partir de matéria-prima de fonte renovável e avaliar seu desempenho adesivo em substratos de espuma flexível e madeira. Adesivos com razões molares NCO/OH iguais a 1, 2, 3 e 4 e diferentes teores de catalisadores foram preparados. Os catalisadores utilizados foram Dibutildilaurato de Estanho (DBTL), em quantidades de 0,8 ou 1% em massa, e Trietilenodiamina (TEDA), nas concentrações em massa de 0,14 e 0,18%, obtendo-se uma relação molar 1:1 entre DBTL/TEDA. A reação de cura foi acompanhada por FTIR. Os adesivos desenvolvidos foram caracterizados por TGA, DSC, tempo de tack-free, ensaios mecânicos de tração dos filmes adesivos e testes de dureza. O poder adesivo foi avaliado através de ensaio de resistência ao descascamento, para substrato de espuma flexível e resistência ao cisalhamento para o substrato de madeira. Os resultados obtidos são promissores, pois foi possível atingir valores até 75% superiores aos adesivos comerciais em resistência ao descascamento e 19% superiores em tensão de cisalhamento. / In this work were development solvent-free bi-component polyurethane (PU) adhesives based on castor oil and Toluene Diisocyanate (TDI), to obtain ecological products by raw material renewable source, and to study their adhesive behavior on PU flexible foam and wood substrates. Adhesives were synthesized with NCO/OH molar ratio of 1, 2, 3 and 4 and different catalysts ratio. The catalysts used were Dibutyltin dilaurate (DBTL), in 0,8 or 1% (w/w), and Triethylenediamine (TEDA), in 0,14 or 0,18% (w/w), obtaining molar ratio DBTL:TEDA of 1:1. The cure reaction was following by FTIR spectroscopy. The PU adhesives were characterized by thermogravimetric analysis (TGA), differential scanning calorimeter (DSC), tack-free time, mechanical testing and hardness measurements. The adhesion was evaluated by peel-test, to flexible foam substrate, and by lap shear test, to wood substrate. The obtained results are promising, in that the adhesion strength of the developed PU adhesives have reached values 75% higher than the commercial foam adhesive for foam substrates and 19% higher than the wood commercial adhesive for wood substrates.
14

Avaliação in vitro da resistência de união adesiva em dentes com anomalias de desenvolvimento

Santos, Gustavo Adolfo Gonçalves Rivera Moreira January 2008 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, 2008. / Submitted by Suelen Silva dos Santos (suelenunb@yahoo.com.br) on 2009-09-16T18:28:18Z No. of bitstreams: 1 Dissert_GustavoAdolfoGRMSantos.pdf: 2086038 bytes, checksum: 35c9ba68231f863d014c0547297e271f (MD5) / Approved for entry into archive by Gomes Neide(nagomes2005@gmail.com) on 2010-07-01T11:49:12Z (GMT) No. of bitstreams: 1 Dissert_GustavoAdolfoGRMSantos.pdf: 2086038 bytes, checksum: 35c9ba68231f863d014c0547297e271f (MD5) / Made available in DSpace on 2010-07-01T11:49:12Z (GMT). No. of bitstreams: 1 Dissert_GustavoAdolfoGRMSantos.pdf: 2086038 bytes, checksum: 35c9ba68231f863d014c0547297e271f (MD5) Previous issue date: 2008 / Dentes com Amelogênese Imperfeita (AI) ou Dentinogênese Imperfeita (DGI) normalmente apresentam necessidade de tratamento por razões funcionais ou estéticas; entretanto, pouco se sabe sobre a influência que estes defeitos no esmalte e na dentina exercem na resistência de união aos materiais restauradores adesivos. O presente estudo teve como objetivos avaliar a resistência de união (RU) entre uma resina composta e o tecido dentinário de dentes afetados por AI e DGI tipo II e caracterizar, após a realização dos ensaios, o tipo de fratura dos espécimes. Para o experimento, foram selecionados terceiros molares de pacientes com DGI Tipo II (n=6) e com AI (n=5). Como grupo controle, foram utilizados 6 dentes de pacientes não afetados. Os dentes foram seccionados no terço oclusal possibilitando a exposição de uma dentina superficial plana, sobre a qual foram confeccionadas coroas de resina composta (Z250, 3M/ESPE), de aproximadamente 4mm de altura, pela técnica incremental. Após 24 horas de armazenamento em água destilada (37°C), a coroa foi seccionada para a obtenção de palitos resina/dentina (área de secção transversal de 1,2mm²). Um total de 104 espécimes: grupo DGI (n=32), grupo AI (n=36) e grupo controle (n=36) foram submetidos ao teste de microtração em uma máquina universal de ensaios (MTS), com o auxílio do dispositivo Bencor Multi-T. Os ensaios foram realizados sob uma velocidade de 0,5mm/min até a ocorrência da fratura dos espécimes. A superfície fraturada foi analisada com ajuda de lupa estereoscópica com aumento de 40x. Os testes ANOVA one-way e ² foram conduzidos para a comparação dos resultados de resistência de união e tipos de fratura, respectivamente. Verificou-se que o grupo DGI tipo II apresentou valores de resistência de união menores, (25,366 ± 7,217 MPa,), em comparação àqueles observados no grupo AI, (42,761 ± 6,375 MPa), e grupo controle, (38,376 ± 10,451 MPa). As fraturas dos espécimes foram majoritariamente do tipo adesivo (86,54%) para todos os tipos de tecido dentinário avaliados. Neste estudo, a adesão ao tecido dentinário de dentes afetados por DGI Tipo II mostrou-se menos resistente, enquanto dentes afetados por AI e dentes hígidos apresentaram valores de resistência de união à dentina semelhantes. _______________________________________________________________________________________ ABSTRACT / Teeth affected by Amelogenesis Imperfecta (AI) or Dentinogenesis Imperfecta (DGI) normally demand restorative treatment for functional and aesthetic reasons however, scarce information is available concerning the influence of enamel and dentin defects on the adhesive restorative materials bond strength. This study evaluated the dentin bond strength and the fracture type characterization of the specimens obtained from teeth affected by DGI type II and AI. Three groups of third molars (6 DGI type II, 5 AI and 6 sound teeth) were sectioned at the occlusal third until exhibiting a flat superficial dentin, over which, composite resin (Z250, 3M/ESPE) buildups of 4 mm of thickness were constructed incrementally. After 24 hours storage in distilled water (37°C), the crown was serially sectioned to obtain sticks (1,2mm2 cross section) for microtensile bond strength testing. A total of 32 (DGI group), 36 (AI group) and 36 (sound teeth group) sticks were tested. The specimens were attached to a universal testing machine (MTS), using a Bencor Multi- T device. The test was performed at a speed of 0.5 mm/min until the fracture of the specimens. The fracture surface was visually analyzed using a stereomicroscope at 40x of magnification. One-way ANOVA and 2 test were performed to compare, respectively, bond strength and fracture types. DGI type II teeth had lower bond strength mean values (25.366 ± 7.217 MPa), when compared with those observed in AI teeth (42.761 ± 6.375 MPa) and sound teeth (38.376 ± 10.451 MPa). Most of the specimens fractures were of adhesive type (86.54%) for all evaluated dentin tissues. In the present study, the adhesion to the DGI type II dentin tissue was less resistant, while AI affected and sound teeth presented very similar dentin bond strength values.
15

Desenvolvimento de adesivos de poliuretano a base de óleo de mamona

Silva, Bianca Bairros Rabello da January 2006 (has links)
Neste trabalho foram desenvolvidos adesivos de poliuretano a base de óleo de mamona e tolueno diisocianato (TDI), livre de solvente com o objetivo de obter produtos ecologicamente corretos a partir de matéria-prima de fonte renovável e avaliar seu desempenho adesivo em substratos de espuma flexível e madeira. Adesivos com razões molares NCO/OH iguais a 1, 2, 3 e 4 e diferentes teores de catalisadores foram preparados. Os catalisadores utilizados foram Dibutildilaurato de Estanho (DBTL), em quantidades de 0,8 ou 1% em massa, e Trietilenodiamina (TEDA), nas concentrações em massa de 0,14 e 0,18%, obtendo-se uma relação molar 1:1 entre DBTL/TEDA. A reação de cura foi acompanhada por FTIR. Os adesivos desenvolvidos foram caracterizados por TGA, DSC, tempo de tack-free, ensaios mecânicos de tração dos filmes adesivos e testes de dureza. O poder adesivo foi avaliado através de ensaio de resistência ao descascamento, para substrato de espuma flexível e resistência ao cisalhamento para o substrato de madeira. Os resultados obtidos são promissores, pois foi possível atingir valores até 75% superiores aos adesivos comerciais em resistência ao descascamento e 19% superiores em tensão de cisalhamento. / In this work were development solvent-free bi-component polyurethane (PU) adhesives based on castor oil and Toluene Diisocyanate (TDI), to obtain ecological products by raw material renewable source, and to study their adhesive behavior on PU flexible foam and wood substrates. Adhesives were synthesized with NCO/OH molar ratio of 1, 2, 3 and 4 and different catalysts ratio. The catalysts used were Dibutyltin dilaurate (DBTL), in 0,8 or 1% (w/w), and Triethylenediamine (TEDA), in 0,14 or 0,18% (w/w), obtaining molar ratio DBTL:TEDA of 1:1. The cure reaction was following by FTIR spectroscopy. The PU adhesives were characterized by thermogravimetric analysis (TGA), differential scanning calorimeter (DSC), tack-free time, mechanical testing and hardness measurements. The adhesion was evaluated by peel-test, to flexible foam substrate, and by lap shear test, to wood substrate. The obtained results are promising, in that the adhesion strength of the developed PU adhesives have reached values 75% higher than the commercial foam adhesive for foam substrates and 19% higher than the wood commercial adhesive for wood substrates.
16

Estudo do comportamento reológico dos adesivos hot melt PSA e sua relação com a composição e as propriedades adesivas

Silva, Schana Andréia da January 2008 (has links)
Devido à sua crescente importância industrial, os adesivos do tipo PSA (Pressure Sensitive Adhesives) vêm sendo amplamente estudados, principalmente na tentativa de explicar e predizer suas propriedades mecânicas e correlacioná-las à composição e às propriedades reológicas do adesivo. Neste trabalho foi estudada a influência de três parâmetros de formulação de adesivos hot melt PSA nas suas propriedades reológicas e mecânicas. A primeira parte do estudo consiste de um planejamento fatorial fracionado 3³-¹, considerando tipo de borracha (SIS, mistura de SIS e SBS e SIS), teor de óleo (10, 15 e 20%), e tipo de resina (mistura de resina alifática hidrogenada e aromática, mistura de resina alifática não-hidrogenada e aromática e copolímero alifático-aromático). Na segunda parte, a influência da relação borracha/resina e do teor de óleo nas propriedades finais foi estudada em uma composição fixa, baseada em SBS e resina copolímero alifático-aromático. Os adesivos preparados foram avaliados em ensaios de caracterização reológica em viscosímetro Brookfield e em reômetro rotacional. Ensaios de avaliação de propriedades mecânicas normalmente utilizados na indústria de adesivos foram realizados para caracterizar os adesivos testados quanto à adesão, à coesão, ao tack e à resistência térmica. Os resultados mostraram que os três parâmetros estudados têm efeito significativo sobre todas as propriedades mecânicas e que estas podem ser correlacionadas às propriedades reológicas. Verificou-se que a resina copolímero alifático-aromático é a melhor resina para adesivos baseados em SBS, permitindo obter-se bom tack nestes sistemas. Este é um importante resultado, já que formulações de hot melt PSA usando apenas SBS como borracha não são muito comuns devido ao seu baixo tack. Além disso, o SBS apresentou menor sensibilidade à perda de coesão, com o incremento do teor de óleo do que o SIS. Finalmente, foram identificadas correlações entre propriedades reológicas e mecânicas, especialmente os relacionados ao tack (Loop Tack) e à resistência térmica (SAFT), que são características essenciais de HMPSA. / In this work, the influence of three parameters of hot melt PSA (pressure sensitive adhesives) formulations on the rheological and mechanical properties of the product was analyzed. The first part of the study consisted on a 3³-¹ fractionated factorial design, considering rubber type (SIS rubber, a SIS and SBS mixture, or SBS rubber), oil content (10, 15 or 20%), and tackifier resin type (hydrogenated aliphatic resin mixed with aromatic resin, non-hydrogenated aliphatic resin mixed with aromatic resin, and aliphatic-aromatic copolymer resin). In the second part, SBS rubber and aliphatic-aromatic copolymer tackifier resin were taken as the basis of the formulation, and the influence of rubber/resin ratio and oil content on the final product properties was analyzed. Rheological measurements were carried out in a Brookfield viscosimeter and a rotational rheometer. The standard tests of the adhesives industry were used to determine adhesion, cohesion, tack and heat resistance for the tested formulations. The results showed that the three parameters studied have significant effects on the mechanical properties of the adhesives and that these effects can be correlated to the rheological properties of the formulation. Aliphatic-aromatic copolymer resin has proven to be the best tackifier resin to SBS based adhesives, allowing to achieve good tack in these systems. This is an important result, since hot melt PSA formulations using only SBS as rubber component are not widely used due to poor tack characteristics. Additionally, sensitivity of the adhesive cohesion to oil content increase was lower for the SBS/aliphatic-aromatic copolymer resin based system when compared to the SIS based adhesives. Complementarily, correlations between rheological parameters and rheological model parameters with tack (Loop Tack) and the heat resistance (SAFT) mechanical properties were identified.
17

Avaliação da resistência de união à dentina de três adesivos universais

Santos, Tamires Sampaio January 2017 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2017. / Made available in DSpace on 2018-02-13T03:14:05Z (GMT). No. of bitstreams: 1 349899.pdf: 2293189 bytes, checksum: 24524efb96a58bfa1b17f8a52b3956f6 (MD5) Previous issue date: 2017 / Objetivo: Avaliar a resistência de união à microtração de três sistemas adesivos universais utilizados no modo autocondicionante. Material e Método: 24 terceiros molares foram divididos em quatro grupos (n=6/grupo), de acordo com o sistema adesivo: G1 ? AdperTM ScotchbondTM Multi Purpose (SMP) (controle); G2 ? Single Bond Universal (SBU); G3 ? All-Bond Universal (ABU); e, G4 ? Clearfil Universal (CFU). Após a construção dos blocos dente/resina fora armazenados em água destilada (37°C / 24 h) e em água (37°C / 3 meses associados à termociclagem (5.000 ciclos, 5/55°C)) e, em seguida, foram preparados filetes de resina-dentina (1,0 mm2). Os espécimes foram submetidos ao teste de resistência de união à tração na máquina de ensaio universal Instron, com velocidade de 0,5 mm/minuto. Os tipos de falha foram observados em microscopia eletrônica de varredura (MEV) e microscopia óptica. Resultados: Os resultados foram analisados pelo teste de variância ANOVA two-way e o teste de Tukey (a = 5%). No teste de microtração, as médias obtidas (MPa) foram as seguintes: 24 h ? G1 (32,31); G2 (49,11); G3 (44,86); G4 (43,61); 3 meses associados à termociclagem (5.000 ciclos) ? G1 (30,03); G2 (44,12); G3 (17,77); G4 (27,15). O armazenamento por 24 horas mostrou valores significativamente maiores de resistência de união em comparação com o tempo de 3 meses de armazenamento associados à termociclagem. ABU e CFU apresentaram diferenças estatísticas entre os tempos de armazenamento. As fraturas do tipo adesivas foram predominantes em todos os sistemas adesivos. Conclusão: As ligações criadas pelo Single Bond Universal foram mais duráveis e estáveis. / Abstract : Aim: This paper aims to evaluate the microtensile bond strength of three universal self-etching adhesive systems. Material and method: 24 third molars were divided into 4 groups (n=6/group), according to the adhesive system: G1 ? Single Bond Universal (SBU); G2 ? AdperTM ScotchbondTM Multi Purpose (SMP) (control); G3 ? All-Bond Universal (ABU); G4 ? Clearfil Universal (CFU). After the resin/tooth blocks were stored in distilled water (37°C / 24 hours) and in water (37°C / 3 months associated with thermocycling (5000 cycles, 5/55°C)). Next, the resin-dentin fillets (1.0 mm2) were prepared. The specimens were submitted to the tensile bond strength test on the Instron universal test machine at a speed of 0.5 mm / minute. The types of failure were observed by scanning electron microscopy (SEM) and optical microscopy. Results: The results were analyzed by the variance test (two-way ANOVA) and the Tukey test (a = 5%). In the microtension test the obtained average (MPa) were as follows: 24 h ? G1 (32,31); G2 (49,11); G3 (44,86); G4 (43,61); 3 months associated with thermocycling (5000 cycles) - G1 (30,03); G2 (44,12); G3 (17,77); G4 (27,15). ABU and CFU presented statistical difference between storage times. The adhesive fractures were predominant in all adhesive systems. Conclusion: The bonds created by the Universal Single Bond were more durable and stable.
18

Resistência de união de um sistema adesivo de condicionamento total com diferentes viscosidades à dentina tratada com Laser de ER:YAG / Bond strength of a total-etch adhesive system with different viscosities to ER:YAG LASER irradiated dentin

Lira, Renato Queiroz Nogueira January 2013 (has links)
LIRA, Renato Queiroz Nogueira. Resistência de união de um sistema adesivo de condicionamento total com diferentes viscosidades à dentina tratada com laser de ER:YAG. 2013. 47 f. Dissertação (Mestrado em Odontologia) - Universidade Federal do Ceará. Faculdade de Farmácia, Odontologia e Enfermagem, Fortaleza, 2013. / Submitted by denise santos (denise.santos@ufc.br) on 2013-12-16T14:05:24Z No. of bitstreams: 1 2013_dis_rqnlira.pdf: 1003430 bytes, checksum: e1bd1025ce8d0fc385ab8e8011f5c805 (MD5) / Approved for entry into archive by denise santos(denise.santos@ufc.br) on 2013-12-16T14:08:42Z (GMT) No. of bitstreams: 1 2013_dis_rqnlira.pdf: 1003430 bytes, checksum: e1bd1025ce8d0fc385ab8e8011f5c805 (MD5) / Made available in DSpace on 2013-12-16T14:08:42Z (GMT). No. of bitstreams: 1 2013_dis_rqnlira.pdf: 1003430 bytes, checksum: e1bd1025ce8d0fc385ab8e8011f5c805 (MD5) Previous issue date: 2013 / Dental cavities prepared with Er:YAG laser may result in greater conservation of sound tissue, further opening of dentinal tubules without the presence of smear layer, few microorganisms in the cavity, and lower pain sensitivity during operative procedure. Whereas laser irradiation may decrease the bond strength of resin materials to dentin, this study examined the effect of viscosity of a two-step total-etch adhesive system on the bonding to dentin irradiated with Er:YAG laser. The prepared dentin was tested in 2 types of surface preparation (diamond tip and Er:YAG laser) and the viscosity of the adhesive at 3 different dilutions (Adper™ Single Bond 2 [SB], SB+10% e SB+20% de ethanol). Sixty human third molars were sectioned and polished, exposing dentin occlusal surfaces. SB adhesive system was used to prepare formulations with different viscosities. The dentin surfaces were acid etched and the adhesives were applied according to the manufacturer's instructions. Composite resin buildups (Filtek™ Z250 XT) of 5 mm were made. Prepared teeth were stored in distilled water (37oC) for 24 h. Specimens were sectioned into sticks (1 mm² of cross sectional area), which were submitted to microtensile test. Physical-mechanical properties, such as contact angle, evaporation rate, degree of conversion, sorption/solubility of water and viscosity of the adhesives were defined. All results were compared with Two-way ANOVA and Tukey multiple comparison test (α=0.05). There was no statistical difference between the values of microtensile for all groups. The viscosity levels did not affect the bond strength of dentin treated either with Er:YAG laser or diamond bur. / Preparos cavitários dentários confeccionados com laser de Er:YAG podem resultar em uma maior conservação de tecidos sadios, maior abertura dos túbulos dentinários sem presença de lama dentinária, menor número de microrganismos na cavidade, além de menor sensibilidade dolorosa durante sua confecção. Considerando que a irradiação a laser pode diminuir a resistência de união de materiais restauradores à dentina, esse estudo analisou o efeito da viscosidade de um sistema adesivo de condicionamento total de dois passos, em dentina irradiada com laser de Er:YAG. A dentina preparada foi testada em 2 tipos de preparo de superfície (ponta diamantada e laser de Er:YAG) e a viscosidade do adesivo em 3 diferentes diluições (Adper™ Single Bond 2 [SB], SB+10% e SB+20% de etanol). Sessenta terceiros molares humanos foram cortados e polidos, expondo superfícies de dentina oclusal. Foi utilizado o sistema adesivo SB para preparar as formulações com diferentes viscosidades. As superfícies de dentina foram condicionadas com ácido fosfórico e os adesivos foram aplicados de acordo com as instruções do fabricante. Platôs de resina composta (Filtek™ Z250 XT) de 5 mm foram confeccionados. Os dentes preparados foram estocados em água destilada (37ºC) por 24 h. Os espécimes foram seccionados em palitos de cerca de 1 mm² de área transversal, os quais foram submetidos ao teste de microtração. Propriedades físico-mecânicas como ângulo de contato, taxa de evaporação, grau de conversão, sorção/solubilidade de água e viscosidade dos adesivos foram definidas. Todos os resultados foram analisados com Two-way ANOVA e teste de comparações múltiplas de Tukey (α=0.05). Não houve diferença estatística entre os valores de microtração para todos os grupos. Os níveis de viscosidade não afetaram a resistência de união da dentina irradiada com laser de Er:YAG ou tratada com ponta diamantada.
19

Avaliação da resistência de união à microtração de um sistema universal à dentina profunda

Gré, Cristina Parise January 2014 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2014. / Made available in DSpace on 2015-02-05T20:46:15Z (GMT). No. of bitstreams: 1 327705.pdf: 2764094 bytes, checksum: f47c75439a021458957e45c281da3616 (MD5) Previous issue date: 2014 / O objetivo deste estudo foi avaliar a resistência de união à microtração de um sistema adesivo universal aplicado em dentina profunda sob diferentes estratégias adesivas.15 terceiros molares humanos tiveram a porção coronária removida , expondo dentina profunda e então, foram divididos em três grupos, de acordo com o sistema adesivo utilizado: G1(controle)-Adper Single Bond 2, sistema adesivo de condicionamento ácido total; G2-Single Bond Universal aplicado no modo autocondicionante; G3-Single Bond Universal aplicado com condiconamento ácido total. Após a aplicação do sistema adesivo, a porção coronária foi reconstruída com a resina composta Filtek Z350. Os corpos - de - prova permaneceram 24h em água destilada à 370C e , então , foram seccionados com um disco de corte diamantado, formando filetes para o teste de microtração, realizado a uma velocidade de 0,5mm/min. Após o teste, a análise do tipo de fratura foi realizada em microscópio óptico e espécimes representativos de cada grupo foram analisados em microscópio eletrônico de varredura . A análise estatística foi realizada, empregando os testes de análise de variância (ANOVA) e a comparação múltipla de Tukey(p=0,05).Não houve diferença estatística entre os grupos e a maioria das falhas ocorreu na interface adesiva para os três grupos testados.Assim, pode-se concluir que o sistema adesivo Single Bond Universal não foi afetado pela estratégia adesiva utilizada e seu desempenho foi equivalente ao do grupo-controle utilizado.<br> / Abstract : This in vitrostudy evaluated the deep dentin microtensile bond strenght of a new multi-purpose dental adhesive applied under different bonding strategies.15 human third molars had a crown portion removed, exposing deep dentin and were divided into three groups, according to the adhesive and etching strategy: G1 (control group) - Adper Single Bond 2, total etch adhesive system. G2- Single Bond Universal applied as a one-step self-etch adhesive;G3- Single Bond Universal applied as a 2-step etch-and-rinse adhesive.Build-ups were constructed with Filtek Z350 and cured in three increments of 2 mm each. Specimens were stored in water (370C/24 h) and then resin dentine sticks were prepared. The sticks were tested under tension at 0.5 mm/min.The failure mode of the specimenswere analyzed using an optic microscope and representative specimens were examined under scanning electron microscope.Statistical analyses were computed using one-way ANOVA and Tukey s test (p=0,05). All the groups ranked in the same statistical subset. The majority of the specimens showed adhesive failures. Single Bond Universal adhesive system was not affected by the adhesion strategy and it s performance was equivalent to that of control group used.
20

Avaliação de sistemas adesivos universais na dentina sob testes de microtração e espectroscopia micro-raman

Farias, David Cardoso Sandes January 2014 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2014. / Made available in DSpace on 2015-02-05T20:51:44Z (GMT). No. of bitstreams: 1 327850.pdf: 23876122 bytes, checksum: 5cb2eabe8aa853b4c8ba03ec9301ee56 (MD5) Previous issue date: 2014 / Avaliar o efeito da aplicação de cargas mecânicas cíclicas sobre a resistência adesiva à microtração de sistemas adesivos universais à dentina quando aplicados com diferentes estratégias adesivas, convencional ou autocondicionante; e quantificar a interdifusão destes adesivos universais na dentina por meio da espectroscopia micro-Raman. Superfícies planas de dentina provenientes de oitenta e oito molares humanos foram distribuídas aleatoriamente em oito grupos de acordo com o tipo de sistema adesivo utilizado (n=10): Scotchbond Universal aplicado seguindo a estratégia adesiva convencional (SU-Er, 3M ESPE) ou seguindo a estratégia adesiva autocondicionante (SU-Se, 3M ESPE); All Bond Universal seguindo a estratégia adesiva convencional (AB-Er, Bisco) ou seguindo a estratégia adesiva autocondicionante (AB-Se, Bisco). Optibond FL (OFL, Kerr), Adper Single Bond Plus (SBP, 3M ESPE), Clearfil SE Bond (CSE, Kerr); e Adper Prompt L-Pop (PLP, 3M ESPE) foram utilizados para comparações. Após realização dos procedimentos adesivos, restaurações com a resina composta TPH3 (Dentsply) foram construídas incrementalmente. Metade das amostras (n=5) foi seccionada para a obtenção de filetes 24 horas após aos procedimentos adesivos e imediatamente submetidas ao teste de resistência adesiva à microtração (µTBS). A outra metade das amostras foi seccionada em filetes após aplicação de cargas mecânicas cíclicas (50.000 ciclos, 50N) e testadas sob µTBS. Para quantificar a infiltração dos sistemas adesivos na interface adesivo/dentina, a análise micro-Raman foi realizada para cada sistema adesivo. Dentes adicionais (n = 8) foram preparados e tratados com os diferentes sistemas adesivos como anteriormente descrito para a avaliação da resistência adesiva à microtração. Cada amostra foi seccionada para obtenção de filetes com 2 mm2. Os filetes foram então polidos e limpos para expor a interface adesiva para a análise sob espectroscopia micro-Raman. Para a análise estatística dos dados, foi empregada a análise de variância de dois fatores (two-way ANOVA) e o teste de Tukey ao nível de 95% de confiança. O condicionamento ácido prévio da dentina produziu um aumento mínimo e não-significativo dos valores de resistência adesiva quando o adesivo SU foi utilizado (p > 0.05). Para o adesivo AB, as médias de resistência adesiva foram influenciadas pelo modo de aplicação (autocondicionante ou convencional) (p < 0.05). Inicialmente, as médias mais altas de resistência adesiva foram obtidas com SU-Er (57,5 MPa), mas estatisticamente semelhantes às médias obtidas com OFL, SBP, CSE e AB-Er (p > 0.05). PLP e AB-Se apresentaram desempenho adesivo semelhantes, que foram estatisticamente inferiores quando comparados aos outros grupos experimentais (p < 0.05). A aplicação de cargas mecânicas cíclicas não afetou os valores de resistência adesiva para todos os grupos, exceto para PLP (de 35,2 para 12,7 MPa; p < 0.05). A espessura da camada híbrida variou entre os diferentes sistema adesivos avaliados, com espessura aproximada de 3.5, 3.5, 4.0, 5.0, 2.5, 5.0, 2.0, 4.0 µm para OFL, SBP, CSE, PLP, SU-Se, SU-Er, AB-Se e AB-Er, respectivamente. O desempenho dos sistemas adesivos universais não foi afetado negativamente pelo modo de aplicação utilizado - autocondicionante ou convencional. A aplicação de cargas mecânicas cíclicas não influenciou os valores de resistência união de adesivos universais à dentina. Variações na profundidade de infiltração da resina e no grau de desmineralização da dentina na interface foram observadas sob espectroscopia micro-Raman.<br> / Abstract : To evaluate the effect of mechanical cyclic loading on the dentin microtensile bond strengths (µTBS) of universal adhesive systems following either a self-etch or an etch-and-rinse bonding strategy and to quantify the diffusion of these single-bottle universal adhesives into dentin using micro-Raman spectroscopy. Flat dentin surfaces from eighty human molars were allocated to eight groups (n=10) and bonded with Scotchbond Universal Adhesive applied using etch-and-rinse approach (SU-Er, 3M ESPE) or using self-etch approach (SU-Se, 3M ESPE); All Bond Universal Adhesive applied using etch-and-rinse approach (AB-Er, Bisco) or using self-etch approach (AB-Se, Bisco). Optibond FL (OFL, Kerr), Adper Single Bond Plus (SBP, 3M ESPE), Clearfil SE Bond (CSE, Kerr); and Adper Prompt L-Pop (PLP, 3M ESPE) were used for comparison. Composite build-ups were constructed incrementally with TPH3 (Dentsply). Half of the specimens (n=5) were sectioned into beams 24 h after the bonding procedures and immediately tested for microtensile bond strengths (µTBS). The other half of the specimens were sectioned into beams immediately after mechanical load cycling (50.000 cycles, 50N) and tested in µTBS. Micro-Raman analysis of adhesive infiltration across the dentin-adhesive interface was carried out for each adhesive. Additional teeth (n=8) were prepared and bonded as previously described for µTBS evaluation. Each specimen was then cut to obtain 2 mm2 slabs. Slabs were then polished and cleaned to expose the adhesive interface for micro-Raman analysis. Data were analyzed by two-way ANOVA and Tukey s post hoc test at the 95% confidence level. The pre-etching treatment produced a minimal and non-significant increase in µTBS for SU adhesive (p > 0.05). For AB, the mean µTBS was influenced by the mode of application (self-etch or etch-and-rinse) (p < 0.05). Initially, the highest mean µTBS were obtained with SU-Er (57.5 MPa), but statistically similar to those of OFL, SBP, CSE and AB-Er (p > 0.05). PLP and AB-Se performed equally, which were statistically lower than those of the other experimental groups (p < 0.05). Mechanical cyclic loading did not affect the µTBS values for all groups except for PLP (from 35.2 to 12.7 MPa; p < 0.05). The widths of the hybrid layers varied, and was ~3.5, 3.0, 4.0, 5.0, 2.5, 5.0, 2.0, 4.0 µm for OFL, SBP, CSE, PLP, SU-Se, SU-Er, AB-Se and AB-Er, respectively. The bonding performance of universal adhesives was not affected by application mode  namely self-etch and etch-and-rinse. Mechanical cyclic loading did not adversely affect the µTBS values of universal adhesives. Variations in the degree of resin infiltration and dentin demineralization on the resin-dentin interface were noticed with micro-Raman spectroscopy.

Page generated in 0.0574 seconds