• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 15
  • 6
  • 4
  • 4
  • 2
  • 1
  • Tagged with
  • 35
  • 24
  • 12
  • 11
  • 9
  • 8
  • 7
  • 7
  • 7
  • 7
  • 6
  • 6
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Développement d’un couplage de chromatographie en phase supercritique et spectrométrie de masse pour l’analyse de substances naturelles / Development of supercritical fluid chromatography coupled to mass spectrometry for natural compounds analysis

Méjean, Marie 17 October 2014 (has links)
L’objectif de ce projet doctoral a été de coupler la chromatographie en phase supercritique (SFC) avec un spectromètre de masse haute résolution pour l’analyse de substances naturelles apolaires. La SFC est une technique dite « verte » contrairement à la chromatographie liquide en phase normale (NPLC), très consommatrice de solvants organiques toxiques pour l’environnement, puisque la phase mobile est principalement constituée de CO2. Le CO2 ayant une faible viscosité, cela implique une diffusivité, des débits élevés et des temps d’analyse courts. Notre attention a été focalisée sur des molécules apolaires : les lipides. Le but était de mettre au point des dosages dans des matrices alimentaires et biologiques et de débuter une approche lipidomique d’étude de la maladie de Parkinson. La première partie a été dédiée au développement du système SFC avec une détection UV, prêté par le constructeur Agilent Technologies. La première étude s’est portée sur 6 composés de la famille des vitamines A. Une phase d’optimisation a été réalisée afin d’obtenir une séparation satisfaisante des composés, en testant différents paramètres chromatographiques comme le type de phase stationnaire ou encore la composition de la phase mobile, afin d’obtenir une résolution optimale. Ensuite, des études de linéarité et de répétabilité ont été réalisées et des limites de détection et de quantification ont été déterminées afin d’obtenir une méthode fiable et robuste. Une deuxième partie a concerné la mise en place du couplage entre la SFC et un spectromètre de masse de type quadripôle-temps de vol (Q-TOF), afin d’améliorer la spécificité et la sensibilité des analyses. Différentes sources d’ionisation ont été utilisées : ESI, APCI et APPI. Chacune des sources présente des modes d’ionisation différents, qui permettent de pouvoir balayer une large gamme de polarité des analytes. Nous avons choisi 8 dérivés de la vitamine E, composés apolaires pour lesquels la SFC paraît être la technique d’analyse idéale. La séparation de ces composés a été optimisée de façon à obtenir une bonne résolution chromatographique et un temps d’analyse minimal. L’ionisation des composés est réalisée avec les 3 sources disponibles en faisant varier les paramètres de sources ou encore le solvant « make-up », de façon à obtenir une sensibilité optimale. La source APPI a été finalement choisie après une étude sur les performances de la méthode. Cette source présente une bonne répétabilité, linéarité et des limites de détection de l’ordre de celles retrouvées dans la littérature par HPLC-MS. Nous avons ensuite réalisé la quantification des ces composés dans 2 types de matrices alimentaire et biologique : l’huile de soja et le plasma de rat. Une troisième partie a été débutée sur le profilage de lipides à polarités variées par SFC-MS. Cette technique se révèle idéale de par la faible polarité de ces composés et leur absence d’absorbance dans le domaine UV. En effet, l’intégrité des lipides peut être altérée suite aux dommages causés par les radicaux libres, qui sont potentiellement impliqués dans de nombreuses maladies neurodégénératives. Il parait primordial de développer des outils analytiques présentant une haute sensibilité et résolution et la possibilité d’accéder aux informations structurales. La source d’ionisation ESI nous a permis de détecter 12 lipides sur les 20 sous-classes analysées en mode positif et 8 lipides en mode négatif. Une application a été réalisée sur un échantillon de plasma humain. Il serait intéressant à l’avenir d’effectuer cette étude en utilisant la source APPI, source propice à l’analyse structurale de lipides et présentant une bonne sensibilité et répétabilité. Ce couplage SFC-MS, présentant une bonne sensibilité et répétabilité, sera par la suite étendu à l’analyse de lipides dans diverses matrices biologiques et pourra à l’avenir être appliqué à l’étude de nouveaux biomarqueurs et au screening rapide d’un grand nombre d’échantillons / The aim of this PhD project was to couple supercritical fluid chromatography (SFC) with a high resolution mass spectrometer for apolar natural compounds analysis. Because mobile phase is principally constituted of CO2, SFC is called “green technic” contrary to normal phase liquid chromatography (NPLC), which uses lot of organic solvents toxic for environment. The CO2 presents a low viscosity, in this way high diffusivity and flow rate, and lower analysis times are obtained. Our work was focused on apolar molecules: the lipids. The aim was to quantify molecules in alimentary and biological matrices and to a lipidomic approach to study Parkinson disease. The first part was to develop the system SFC with a UV detection on a system on loan by Agilent Technologies. This first study was carried out on 6 vitamin A compounds. An optimization of chromatographic parameters has been realized in order to obtain a good separation of the compounds. Then, linearity, repeatability, detection and quantification limits have been determined in order to have a reliable and robust method. A second part concerned the coupling of SFC and a quadrupole time-of-flight mass spectrometer (Q-TOF), in order to improve specificity and sensitivity of analysis. Different ionization sources have been tested: ESI, APCI and APPI. Each ion source presents different ionization mode, which permits to analyze a wide range of polarities of compounds. We have chosen 8 vitamin E derivatives, which are apolar compounds for which SFC seems to be well suited. Separation compounds have been optimized in order to have a good chromatographic resolution and a short analysis time. This compounds ionization is realized with the 3 sources, varying ionization parameters and make-up solvent, to have an optimal sensitivity. The APPI source has been chosen after a performance evaluation method. This source presents a good repeatability, linearity and detection limit in the same order of magnitude than those found in the literature by HPLC-MS. Then we have quantified these compounds in alimentary and biological matrices: a soya oil and plasma rat. A third study has been started on lipid profiling with various polarities by SFC-MS. This technic is well suited because of the low polarity of this molecules and their lack of absorbance in the UV range. The integrity of lipids can be altered with damages caused by free radicals, and are potentially involved in neurodegenerative diseases. It is essential to develop analytical systems with a high sensitivity and resolution and the possibility to access to structural information. The ESI source permits to detect 12 lipids on the 20 sub-classes analyzed in positive ion mode and 8 lipids in negative mode. An application has been realized on human plasma. In the future, it will be interesting to analyze these lipids with the APPI source, which is good choice for structural analysis of lipids, with good sensitivity and repeatability. Studies with this SFC-MS system, presenting good sensitivity and repeatability, will be extended to lipid analysis in biological matrices and could be applied to new biomarkers study and for fast screening of a large number of samples
32

Dégradation chimique et biologique de neuf contaminants émergents dans les eaux de surfaces et les effluents primaires d’eaux usées municipales

Cormier, Guillaume 04 1900 (has links)
Un protocole inspiré du test de simulation 309 de l’Organisation de coopération et de développement économiques (OCDE) nous a permis de mesurer la dégradation chimique (excluant la photolyse) dans des eaux de surface de même que la dégradation chimique et biologique de neuf contaminants émergents dans l’effluent d’un décanteur primaire d’eau usée municipale. Les données étaient compatibles avec le modèle de cinétique de pseudo ordre un. Les résultats démontrant une persistance de plus d’un an dans les eaux de surface et de 71 jours dans l’effluent du décanteur primaire suggèrent que les dégradations chimique et biologique ne contribuent pas significativement à la diminution de: atrazine, déséthylatrazine, carbamazépine et diclofénac dans la phase aqueuse des systèmes testés. Les autres composés se sont dégradés à différents niveaux. Le 17ß-estradiol ainsi que l’éthinylestradiol, la noréthindrone, la caféine et le sulfaméthoxazole ont tous été sujet à la dégradation biologique dans les effluents du décanteur primaire d’eau usée avec des constantes de dégradation k et des demi-vies t1/2 mesurées allant respectivement de 0.0082 à 0.59 j-1 et de 1.2 à 85 jours. Les paramètres de cinétique mesurés peuvent être combinés aux concentrations typiques des composés à l’étude dans un décanteur primaire d’eau usée pour y calculer leur vitesse de dégradation. Cependant, puisque les décanteurs primaires dans les usines de traitement d’eaux usées ont généralement des temps de résidence de quelques heures seulement, il est improbable que les neufs contaminants émergents à l’étude diminuent significativement par ces processus durant leur passage dans le compartiment. / A protocol inspired by the OECD 309 simulation test allowed us to measure the chemical (excluding photolysis) degradation in surface waters as well as the chemical and biological degradation potential of 9 emerging contaminants in urban primary settling tank (PST) effluents. The data confirmed that a pseudo first order kinetic model provided a good fit. The results suggest that chemical and biological degradation will not significantly contribute to the disappearance of atrazine, desethylatrazine, carbamazepine and sulfamethoxazole in the aqueous phase of the tested systems given the reported persistency of more than a year in surface waters and 71 days in PST effluents. Other compounds were more easily degraded and 17ß-estradiol, ethinylestradiol, norethindrone, caffeine and sulfamethoxazole were all amenable to biological degradation in PST effluents, with measured degradation rate constants k and half-lives ranging respectively from 0.0082-0.59 d-1 and 1.2-85 days. Since PSTs in WWTPs generally have a water residence time of a few hours and considering the typical concentrations of such ECs’ in those compartments, it is unlikely that significant disappearance will occur during their passage through the PST.
33

Développement d’une nouvelle méthode d’analyse multi-résidus par LDTD/APCI-MS/MS pour la quantification de pesticides et de produits pharmaceutiques dans les eaux usées

Boisvert, Michel 04 1900 (has links)
Une nouvelle méthode d'extraction en phase solide (SPE) couplée à une technique d'analyse ultrarapide a été développée pour la détermination simultanée de neuf contaminants émergents (l'atrazine, le déséthylatrazine, le 17(béta)-estradiol, l'éthynylestradiol, la noréthindrone, la caféine, la carbamazépine, le diclofénac et le sulfaméthoxazole) provenant de différentes classes thérapeutiques et présents dans les eaux usées. La pré-concentration et la purification des échantillons a été réalisée avec une cartouche SPE en mode mixte (Strata ABW) ayant à la fois des propriétés échangeuses de cations et d'anions suivie d'une analyse par une désorption thermique par diode laser/ionisation chimique à pression atmosphérique couplée à la spectrométrie de masse en tandem (LDTD-APCI-MS/MS). La LDTD est une nouvelle méthode d'introduction d'échantillon qui réduit le temps total d'analyse à moins de 15 secondes par rapport à plusieurs minutes avec la chromatographie liquide couplée à la spectrométrie de masse en tandem traditionnelle (LC-MS/MS). Plusieurs paramètres SPE ont été évalués dans le but d'optimiser l'efficacité de récupération lors de l'extraction des analytes provenant des eaux usées, tels que la nature de la phase stationnaire, le débit de chargement, le pH d'extraction, le volume et la composition de la solution de lavage et le volume de l'échantillon initial. Cette nouvelle méthode a été appliquée avec succès à de vrais échantillons d'eaux usées provenant d'un réservoir de décantation primaire. Le recouvrement des composés ciblés provenant des eaux usées a été de 78 à 106%, la limite de détection a été de 30 à 122 ng L-1, alors que la limite de quantification a été de 88 à 370 ng L-1. Les courbes d'étalonnage dans les matrices d'eaux usées ont montré une bonne linéarité (R2 > 0,991) pour les analytes cibles ainsi qu’une précision avec un coefficient de variance inférieure à 15%. / A new solid phase extraction (SPE) method coupled to a high throughput sample analysis technique was developed for the simultaneous determination of nine selected emerging contaminants (atrazine, desethylatrazine, 17(beta)-estradiol, ethynylestradiol, northindrone, caffeine, carbamazepine, diclofenac and sulfamethoxazole) comprising drugs from different therapeutic classes present in wastewater. Sample pre-concentration and clean-up was performed with a mixed-mode SPE cartridge (Strata ABW) having both cation and anion exchange properties followed by analysis by laser diode thermal desorption/atmospheric pressure chemical ionization coupled to tandem mass spectrometry (LDTD-APCI-MS/MS). The LDTD is a new high-throughput sample introduction method, which reduces total analysis time to less than 15 seconds compared to minutes with traditional liquid-chromatography coupled to tandem mass spectrometry (LC-MS/MS). Several SPE parameters were evaluated in order to optimize recovery efficiencies when extracting analytes from wastewater, such as the nature of stationary phase, the loading flow rate, the extraction pH, the various volume and composition of the washing solution and the initial sample volume. The method was successfully applied to real wastewater samples from a primary sedimentation tank. Recoveries of target compounds from wastewater ranged from 78 to 106 %, the limit of detection ranged from 30 to 122 ng L-1 while the limit of quantification ranged from 88 to 370 ng L-1. Calibration curves in wastewater matrix showed good linearity (R2 > 0.991), for all target analytes, and precision (intraday and interday) showed a coefficient of variance below 15%.
34

Novel Solid Phase Extraction and Mass Spectrometry Approaches to Multicomponent Analyses in Complex Matrices

Amini, Nahid January 2010 (has links)
Analysis of compounds present in complex matrices is always a challenge, which can be partly overcome by applying various sample preparation techniques prior to detection. Ideally, the extraction techniques should be as selective as possible, to minimize the concentration of interfering substances. In addition, results can be improved by efficient chromatographic separation of the sample components. The elimination of interfering substances is especially important when utilizing mass spectrometry (MS) as a detection technique since they influence the ionization yields. It is also important to optimize ionization methods in order to minimize detection limits. In the work this thesis is based upon, selective solid phase extraction (SPE) materials, a restricted access material (RAM) and graphitized carbon black (GCB) were employed for clean up and/or pre-concentration of analytes in plasma, urine and agricultural drainage water prior to liquid chromatography/mass spectrometry (LC/MS). Two SPE formats, in which GCB was incorporated in µ-traps and disks, were developed for cleaning up small and large volume samples, respectively. In addition, techniques based on use of sub-2 µm C18 particles at elevated temperatures and a linear ion trap (LIT) mass spectrometer were developed to improve the efficiency of LC separation and sensitivity of detection of 6-formylindolo[3,2-b]carbazole (FICZ) metabolites in human urine. It was also found that GCB can serve not only as a SPE sorbent, but also as a valuable surface for surface-assisted laser desorption ionization (SALDI) of small molecules. The dual functionality of GCB was utilized in a combined screening-identification/quantification procedure for fast elimination of negative samples. This may be particularly useful when processing large numbers of samples. SALDI analyses of small molecules was further investigated and improved by employing two kinds of new surfaces: oxidized GCB nanoparticles and silicon nitride.
35

Développement d’une nouvelle méthode d’analyse multi-résidus par LDTD/APCI-MS/MS pour la quantification de pesticides et de produits pharmaceutiques dans les eaux usées

Boisvert, Michel 04 1900 (has links)
Une nouvelle méthode d'extraction en phase solide (SPE) couplée à une technique d'analyse ultrarapide a été développée pour la détermination simultanée de neuf contaminants émergents (l'atrazine, le déséthylatrazine, le 17(béta)-estradiol, l'éthynylestradiol, la noréthindrone, la caféine, la carbamazépine, le diclofénac et le sulfaméthoxazole) provenant de différentes classes thérapeutiques et présents dans les eaux usées. La pré-concentration et la purification des échantillons a été réalisée avec une cartouche SPE en mode mixte (Strata ABW) ayant à la fois des propriétés échangeuses de cations et d'anions suivie d'une analyse par une désorption thermique par diode laser/ionisation chimique à pression atmosphérique couplée à la spectrométrie de masse en tandem (LDTD-APCI-MS/MS). La LDTD est une nouvelle méthode d'introduction d'échantillon qui réduit le temps total d'analyse à moins de 15 secondes par rapport à plusieurs minutes avec la chromatographie liquide couplée à la spectrométrie de masse en tandem traditionnelle (LC-MS/MS). Plusieurs paramètres SPE ont été évalués dans le but d'optimiser l'efficacité de récupération lors de l'extraction des analytes provenant des eaux usées, tels que la nature de la phase stationnaire, le débit de chargement, le pH d'extraction, le volume et la composition de la solution de lavage et le volume de l'échantillon initial. Cette nouvelle méthode a été appliquée avec succès à de vrais échantillons d'eaux usées provenant d'un réservoir de décantation primaire. Le recouvrement des composés ciblés provenant des eaux usées a été de 78 à 106%, la limite de détection a été de 30 à 122 ng L-1, alors que la limite de quantification a été de 88 à 370 ng L-1. Les courbes d'étalonnage dans les matrices d'eaux usées ont montré une bonne linéarité (R2 > 0,991) pour les analytes cibles ainsi qu’une précision avec un coefficient de variance inférieure à 15%. / A new solid phase extraction (SPE) method coupled to a high throughput sample analysis technique was developed for the simultaneous determination of nine selected emerging contaminants (atrazine, desethylatrazine, 17(beta)-estradiol, ethynylestradiol, northindrone, caffeine, carbamazepine, diclofenac and sulfamethoxazole) comprising drugs from different therapeutic classes present in wastewater. Sample pre-concentration and clean-up was performed with a mixed-mode SPE cartridge (Strata ABW) having both cation and anion exchange properties followed by analysis by laser diode thermal desorption/atmospheric pressure chemical ionization coupled to tandem mass spectrometry (LDTD-APCI-MS/MS). The LDTD is a new high-throughput sample introduction method, which reduces total analysis time to less than 15 seconds compared to minutes with traditional liquid-chromatography coupled to tandem mass spectrometry (LC-MS/MS). Several SPE parameters were evaluated in order to optimize recovery efficiencies when extracting analytes from wastewater, such as the nature of stationary phase, the loading flow rate, the extraction pH, the various volume and composition of the washing solution and the initial sample volume. The method was successfully applied to real wastewater samples from a primary sedimentation tank. Recoveries of target compounds from wastewater ranged from 78 to 106 %, the limit of detection ranged from 30 to 122 ng L-1 while the limit of quantification ranged from 88 to 370 ng L-1. Calibration curves in wastewater matrix showed good linearity (R2 > 0.991), for all target analytes, and precision (intraday and interday) showed a coefficient of variance below 15%.

Page generated in 0.0133 seconds