• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 77
  • Tagged with
  • 77
  • 77
  • 31
  • 24
  • 19
  • 17
  • 17
  • 14
  • 13
  • 13
  • 12
  • 11
  • 11
  • 11
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Estudo das perdas de água no sistema de abastecimento e nas residências do conjunto Benjamim Sodré

VIÉGAS, Alessandro Abadessa 07 August 2009 (has links)
Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2013-03-12T16:42:59Z No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_EstudoPerdasAgua.pdf: 23758453 bytes, checksum: 0e0cd127ce9751e98f1eaeed0af414c2 (MD5) / Approved for entry into archive by Ana Rosa Silva(arosa@ufpa.br) on 2013-03-13T17:33:45Z (GMT) No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_EstudoPerdasAgua.pdf: 23758453 bytes, checksum: 0e0cd127ce9751e98f1eaeed0af414c2 (MD5) / Made available in DSpace on 2013-03-13T17:33:45Z (GMT). No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_EstudoPerdasAgua.pdf: 23758453 bytes, checksum: 0e0cd127ce9751e98f1eaeed0af414c2 (MD5) Previous issue date: 2009 / Neste trabalho é apresentado um estudo das perdas de água no sistema de abastecimento e nas residências do Conjunto Benjamim Sodré. O trabalho foi dividido em duas etapas, sendo a primeira experimental e a segunda de resultados. Posteriormente os dados foram tratados e avaliados e os principais resultados foram: a caracterização e avaliação do cadastro de consumidores, o volume faturado e medido das subcategorias do Conjunto, bem como, as vazões de todo o Sistema de Abastecimento de Água (SAA). Além disso, foram determinados alguns indicadores básicos de desempenho, como índice de perda na distribuição (70,04%), índice de perda no faturamento (70,61%), índice linear bruto de perda (157,96 L/m.dia), índice de perda por ligação (1.446 L/ligação.dia), índice de hidrometração (72,27%) e o Índice Global de Perdas (70,93%). Além disso, foi possível ter o conhecimento do nível sócio-econômico de 30% população residente, das subcategorias R2 e R3 no Conjunto (176 imóveis), onde os resultados mostraram que cerca de 94% dos entrevistados que pagam somente uma taxa para consumo afirmaram praticar desperdícios de água em suas residências. Procurou-se analisar a qualidade da água fornecida a população e cerca de 71,50% dos entrevistados considerou de má qualidade, o que de certa forma pode estar contribuindo com ocorrências de doenças de veiculação hídrica, pois nos últimos anos foi verificado que 24% da população tiveram problemas como diarréias, verminoses, hepatite A e escabiose. Além disso, foi feita uma avaliação do uso da água nas diversas atividades domésticas das subcategorias R2 e R3. Há uma perda de R$ 426,38 ao mês na conta de 15 consumidores que alegaram ter vazamentos na residência. Foi mostrado que para a atividade de lavar louça o consumidor teria uma redução no valor da conta de água de 89,28% em média, para tomar banho 43,66%, lavar roupa na máquina 34,23%, para lavar o pátio ou a calçada 84,80%, e para escovar os dentes 17,06%, referentes as subcategorias R2 e R3. / This work presents a study of water losses in the water supply system of Benjamim Sodré Sector. The work was divided in two steps, as follows: experimental step and results step. Later, data were evaluated and the main results have focused on: characterization and evaluation of the consumers register, revenue and measured water from the down categories of the sector, as well as, the Water Supply System water flows. Besides that, it was made the calculation of some basic performance indicators, such as (index): water loss in the distribution (70,04%), water loss in the revenue (70,61%), water gross loss linear (157,96 L/m.d), connection water loss (1.446,41 L/connection.day), measurement (72,27%) and the global losses (70,93%). Also, it was possible to know the socioeconomic level of the population (30%) of the down categories R2 and R3 of the sector (176 houses), in which the results showed that about 94% of the interviewees who pay only the water bill affirmed to practice waster losses in their houses. The water quality was also analyzed. And it was verified that about 71,50% of the interviewees have considered it bad quality, which may contribute in a important way to the occurrences of Transmissible Hydric Diseases, because it was verified that 24% of the population presented problems concerning to diarrheas, worms, hepatitis A and scabies in the last years. It was made an evaluation of the water uses in the several domestic activities of the down categories R2 and R3. There is a loss of R$ 426,38 per month in the water bill of all consumers that contribute to water leaks in their homes. Finally, it is shown that for the activity of washing the dishes the consumer would have a reduction on the water bill average value of 89,28%. Additionally, to take bath: 43,66%, to wash clothes: 34,23%, to wash the sidewalk: 84,80%, and to brush their teeth 17,06%, referring the down categories R2 and R3.
62

Avaliação da operação e estimativa das perdas de água e de energia elétrica no 3º setor de abastecimento de água da região metropolitana de Belém

BARRETO, Gilberto Caldeira 27 December 2006 (has links)
Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2013-03-13T22:17:52Z No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_AvaliacaoOperacaoEstimativa.pdf: 7689308 bytes, checksum: cbf76c5da530ac010c86e0dc1b43c27b (MD5) / Approved for entry into archive by Ana Rosa Silva(arosa@ufpa.br) on 2013-03-18T12:53:10Z (GMT) No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_AvaliacaoOperacaoEstimativa.pdf: 7689308 bytes, checksum: cbf76c5da530ac010c86e0dc1b43c27b (MD5) / Made available in DSpace on 2013-03-18T12:53:10Z (GMT). No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_AvaliacaoOperacaoEstimativa.pdf: 7689308 bytes, checksum: cbf76c5da530ac010c86e0dc1b43c27b (MD5) Previous issue date: 2006 / Eletrobras - Centrais Elétricas Brasileiras S.A. / Avaliação da operação e a determinação das perdas de água e energia do 3° Setor de abastecimento de água da Região Metropolitana de Belém. Essa pesquisa foi desenvolvida no período de janeiro a dezembro de 2006, tendo 3 etapas. Na primeira etapa foram determinados teoricamente os parâmetros operacionais, para possibilitar a comparação com os resultados obtidos da segunda etapa, na qual foram desenvolvidas atividades de monitoramento nas unidades de reservação e de elevação de água. Na terceira etapa foram estimadas as perdas de água e energia elétrica no 3° Setor. Os resultados possibilitaram observar que a falta de instrumentação para monitoramento e controle dos parâmetros operacionais, e a capacidade insuficiente do reservatório elevado, resultam em operações sem rotina planejada, o que acaba incorrendo em perdas de água e energia elétrica. O volume de água perdido foi estimado em 423.847 m³/mês, o que representa 42,58 % do volume total distribuído (989.580 m³/mês). O valor que a COSANPA deixa de arrecadar mensalmente com essa perda é de R$ 508.616,00. A perda de energia referente ao volume de água perdido no 3° setor foi estimada em 105.962 kWh/mês, o que representa um custo médio de R$ 21.192,4 ao mês ou R$ 254.308,8 ao ano. / Evaluation of the operation and the determination of the loss of water and energy of the 3rd sector of water supplying of Belém metropolitan region. This search was developed in the period of January to December of 2006, in three phases. In the first phase was theoretically determined the operational standard, to make possible the comparison between the results obtained in the second phase, in which one was developed monitoring activities in the water´s reservation and elevation unities. In the third phase was estimated the loss of water and electric energy in the 3rd sector. The results made possible observe that the lack of tools to monitor and control of the standard operational, and the insufficient capacity of the elevated reservoir, results in operations without planned routine, what produces loss of water and electric energy. The volume of lost water was estimated in 423.847 m³/month, what represent 42,58 % of the total volume distributed (989.580 m³/month). The value that the COSANPA does not gain per month with this loss are R$ 508.616,00. The loss of energy referring to the volume of lost water in the 3° sector was estimated in 105.962 kWh/month, what represent a medium cost of R$ 21.192,4 per month or R$ 254.308,8 per year.
63

Espacialização de informações na gestão de sistemas de abastecimento de água utilizando sistema de informação geográfica

SANTOS, Aline Christian Pimentel Almeida 16 June 2010 (has links)
Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2015-02-02T20:39:44Z No. of bitstreams: 2 license_rdf: 22974 bytes, checksum: 99c771d9f0b9c46790009b9874d49253 (MD5) Dissertacao_EspacializacaoInformacoesGestao.pdf: 12766345 bytes, checksum: 0e920ee164a74ebd25be5a81313d2d39 (MD5) / Approved for entry into archive by Ana Rosa Silva (arosa@ufpa.br) on 2015-02-03T17:57:56Z (GMT) No. of bitstreams: 2 license_rdf: 22974 bytes, checksum: 99c771d9f0b9c46790009b9874d49253 (MD5) Dissertacao_EspacializacaoInformacoesGestao.pdf: 12766345 bytes, checksum: 0e920ee164a74ebd25be5a81313d2d39 (MD5) / Made available in DSpace on 2015-02-03T17:57:56Z (GMT). No. of bitstreams: 2 license_rdf: 22974 bytes, checksum: 99c771d9f0b9c46790009b9874d49253 (MD5) Dissertacao_EspacializacaoInformacoesGestao.pdf: 12766345 bytes, checksum: 0e920ee164a74ebd25be5a81313d2d39 (MD5) Previous issue date: 2010 / FAPESPA - Fundação Amazônia de Amparo a Estudos e Pesquisas / Avaliar a espacialização de informações na gestão de Sistema de Abastecimento de Água (SAA). Para isso, foram definidos e adotados os dados da pesquisa (Fase 1), sendo dividido em dados de perdas reais, comerciais e Despesas de exploração. Na Fase 2, a base cartográfica da área de estudo e os dados adotados foram armazenados e organizados em Sistema de Informação Geográfica (SIG), utilizando o software ArcGis 9.3, onde foi construído o modelo de dados para a pesquisa, e definida a topologia a ser utilizada para identificação dos dados espacializados, a construção do banco de dados georreferenciado e a criação dos layers. Na fase 3 foi realizado o cálculo do balanço hídrico nas principais unidades dos SAAs estudados sendo determinadas as perdas na adução de água bruta, no tratamento, na reservação, e na distribuição. Na fase 4 foram calculados indicadores para avaliar o desempenho dos SAAs, como: índice de cobertura, índice total de perda real, índice de perda na arrecadação, índice de perda de faturamento, índice de consumo de energia em SAA, índice de despesas com energia elétrica, entre outros. Na fase 5 foi proposta a espacialização e apresentação em SIG dos resultados obtidos nas fases anteriores. Com isso, considerando os dados adotados, foi possível identificar os valores das perdas reais e dos indicadores de desempenho em cada setor do SAA estudado, sendo, por exemplo, o setor 9, o que apresentou maior índice de perda total, chegando a 59,10%, seguido dos setores 4, 8 e 5. A perda mais significante para o sistema foi a perda na distribuição, com o setor 9 apresentando perda de 57%; a perda no tratamento foi de 3,4%, no setor 3; e os setores com maior índice de perda na adução, foram os setores 6 e 8, com 3,5%. Os percentuais de água não faturada, foram maiores nos setores 1 e 5. Os setores 1, 3, 4 e 6 são os que apresentaram maior consumo de energia elétrica por volume de água produzido. Portanto, a espacialização dos dados em SIG facilitou a visualização e análise dos dados adotados na pesquisa. / To evaluate the spatial information in the management of Water Supply System (ATS). For this they were defined and adopted to the survey (Phase 1), being divided into data of actual losses, commercial and operating expenses. In Phase 2, the base map of study area and data used were stored and organized in a Geographic Information System (GIS) using ArcGIS 9.3 software, which built the data model for the study, and defined the topology be used for identification of specialized data, building the database and the creation of georeferenced layers. In phase 3 was calculated from water balance in the main units of SAAs studied with certain losses in raw water supply, treatment, on the reservation, and distribution. In phase four indicators were calculated to evaluate the performance of SAAs, including: coverage index, total index of actual loss, loss index in the collection, rate of loss of business, index of energy consumption in SAA, index of energy costs Electric, among others. In phase 5 was proposed to the spatial and GIS presentation of the results obtained in earlier phases. Thus, considering the data adopted, it was possible to identify the values of actual losses and performance indicators in each sector of the SAA studied, being, for example, sector 9, which presented the highest rate of total loss, reaching 59, 10%, followed by sections 4, 8 and 5. The most significant loss for the system was the loss distribution, with 9 industry to a loss of 57% loss on treatment was 3.4% in the third sector, and sectors with the highest loss of adduction weresectors 6 and 8, with 3.5%. The percentage of water unaccounted were higher in sectors 1 and 5. Sectors 1, 3, 4 and 6 are those with the highest energy consumption per volume of water produced. Therefore, the spatial data in GIS facilitated the visualization and data analysis adopted in this research.
64

Desenvolvimento de modelo de sistema de informações geográficas para avaliação da eficiência hidroenergética em sistemas de abastecimento de água / Geographic information system model development for evaluate thehydro-energyefficiency of water supply systems

SANTOS, Aline Christian Pimentel Almeida 29 October 2015 (has links)
Submitted by Cássio da Cruz Nogueira (cassionogueirakk@gmail.com) on 2017-02-03T11:52:34Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_DesenvolvimentoModeloSistemas.pdf: 11151369 bytes, checksum: be86db933688edc354add13e97611b70 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-02-07T16:34:32Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_DesenvolvimentoModeloSistemas.pdf: 11151369 bytes, checksum: be86db933688edc354add13e97611b70 (MD5) / Made available in DSpace on 2017-02-07T16:34:32Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_DesenvolvimentoModeloSistemas.pdf: 11151369 bytes, checksum: be86db933688edc354add13e97611b70 (MD5) Previous issue date: 2015-10-29 / Desenvolvimento de metodologia para a avaliação do desempenho hidroenergético de Sistemas de Abastecimento de Água (SAA) utilizando modelo de Sistema de Informações Geográficas (SIG) para auxiliar na tomada de decisão na operação de SAAs. O modelo desenvolvido em plataforma SIG possibilita o registro, a sistematização e a espacialização dos dados hidroenergéticos, a fim de evitar gastos excessivos com a energia elétrica agregada ao volume de água disponibilizado para consumo. Na 1ª Etapa foram identificados os parâmetros hidroenergéticos utilizados nos atuais métodos de gerenciamento de SAA e, em seguida, definidos os dados e indicadores para a representação espacial no modelo do desempenho hidroenergético por setor e por unidade de abastecimento de água. Na 2ª Etapa foi desenvolvido o modelo de gestão em SIG por meio da IDE Delphi XE5 e da plataforma TatukGis, em três fases: Construção do banco de dados geográfico (Fase 1); Construção do módulo SIG (Fase 2) e Construção do módulo hidroenergético (Fase 3). A última Etapa (3ª Etapa) foi destinada a avaliação da funcionalidade do modelo desenvolvido, sendo simulado o funcionamento do SAA Bolonha, da Região Metropolitana de Belém, Pará, Brasil, o que permitiu a espacialização dos dados e indicadores para identificação dos setores com melhor e com pior desempenho hidroenergético. A ferramenta de construção de mapas de graduação de cores mostrou-se eficiente, permitindo a rápida identificação do melhor resultado do índice de consumo de energia elétrica no setor 9 da Zona Central (0,62 KWh/m³), bem como do pior índice de perda total no setor 7 da Zona Central (54,29%). Além da ferramenta para sinalização de alerta para os indicadores acima da meta estabelecida pelo usuário, que possibilitou a identificação do setor 7 com o pior índice de consumo de energia elétrica (0,85 KWh/m³). Com o trabalho foi constatado que o modelo SIGHE2A é uma ferramenta que permite e agiliza a avaliação do desempenho hidroenergético de SAA, especialmente por facilitar a identificação do problema e a tomada de decisão. / Development of methodology for evaluating the performance of hydro-energy Water Supply Systems (WSS) using System Model of Geographical Information (GIS) to assist in decision-making in the SAAs operation. The model developed in GIS platform enables registration, systematization and the spatial distribution of hydro data in order to avoid excessive spending on electricity aggregate the volume of water available for consumption. In Stage 1 the hydro-energy parameters were identified WSSs used in current management methods and then set the data and indicators for the spatial representation in the model of the hydro-energy performance by sector and water supply unit. In the 2nd stage was developed the management model in GIS through Delphi IDE XE5 and TatukGIS platform in three phases: geographic database construction (Phase 1); Construction of GIS module (Phase 2) and construction of hydro-energy module (Phase 3). The last step (Step 3) was submitted to evaluation of the model developed functionality, which simulated the operation of the WSS Bolonha, the Metropolitan Region of Belém, Pará, Brazil, which allowed the spatial data and indicators to identify the sectors with best and hydro-energy worst performance. The color grading maps building tool was efficient, allowing quick identification of the best result of the electricity consumption index in sector 9 of the Central Zone (0.62 KWh / m³) and the worst index total loss in sector 7 of the Central Zone (54.29%). In addition to the warning signs for tool for the indicators above the target set by the user, which enabled the identification of sector 7 with the worst energy consumption index (0.85 KWh / m³). With the work it was found that the SIGHE2A model is a tool that enables and streamlines the evaluation of the hydro-Energy performance WSS, especially to facilitate problem identification and decision making.
65

Análise dos impactos da dinâmica de sólidos e de nutrientes na qualidade da água de ambiente lêntico utilizado no abastecimento de comunidades amazônicas / Analysis of the impacts of solid dynamics of nutrients and water quality of the environment lentic used in supply communities amazon

SARAIVA, André Luis de Lima 08 1900 (has links)
Submitted by Nathalya Silva (nathyjf033@gmail.com) on 2017-04-24T19:44:29Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_AnaliseImpactosDinamica.pdf: 5095219 bytes, checksum: e85c565d710c19b01a0a83f4a06ae946 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-04-25T19:55:39Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_AnaliseImpactosDinamica.pdf: 5095219 bytes, checksum: e85c565d710c19b01a0a83f4a06ae946 (MD5) / Made available in DSpace on 2017-04-25T19:55:39Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_AnaliseImpactosDinamica.pdf: 5095219 bytes, checksum: e85c565d710c19b01a0a83f4a06ae946 (MD5) Previous issue date: 2012-08 / FAPESPA - Fundação Amazônia de Amparo a Estudos e Pesquisas / Os mananciais do Utinga, formados pelos lagos Bolonha e Água Preta, estão contidos em uma Área de Proteção Ambiental - APA e são utilizados pela Companhia de Saneamento do Pará – COSANPA, para o abastecimento da população da Região Metropolitana de Belém - RMB. Esses mananciais são constituídos pelo rio Guamá, onde a água é captada e enviada por recalque ao lago Água Preta, que por um canal artificial com escoamento por gravidade, alimenta o lago Bolonha, e é bombeado para a Estação de Tratamento de Água - ETA. Os principais problemas de poluição/contaminação desses mananciais surgiram com o avanço urbanístico desordenado, que ocasionam o lançamento indevido de esgoto e resíduos sólidos dos bairros, favelas e conjuntos residenciais próximos às principais nascentes. O objetivo deste estudo foi de utilizar ferramentas para subsidiar o monitoramento e conhecimento da qualidade da água no lago Água Preta, visando prevenir e/ou corrigir processos de degradação, tais ferramentas são as análises multivariadas de parâmetros abióticos e clorofila a, balanço de nutrientes e modelagem hidrodinâmica com intuito de observar a dispersão do transporte de sedimentos. Foram realizadas coletas de águas superficiais em 3 pontos escolhidos estrategicamente para avaliar a influência antrópica no lago Água Preta, bem como dos sedimentos suspensos que são carreados para dentro do lago. Os pontos de coleta de amostras foram georreferenciados com GPS (modelo GARMIN) e as coletas de águas superficiais foram realizadas com a garrafa de Van Dorn de 2,5 L e transportadas para o Laboratório de Química Ambiental (LQA), localizado na Universidade Federal Rural da Amazônia, para posteriores análises. As coletas foram realizadas durante os meses de março, maio, junho, agosto, setembro e outubro do ano de 2010, coincidindo com os períodos de maior e de menor precipitação pluviométrica. Os dados dos parâmetros abióticos e de clorofila a foram analisados por métodos de estatística descritiva e de análises de componentes principais. Também foram realizadas análises do balanço de massa de água e de nutrientes e adotou-se o uso do modelo hidrodinâmico do programa de modelagem SisBAHIA (Sistema Base de Hidrodinâmica Ambiental), visando simular as condições hidrodinâmicas do lago Água Preta durante um ano. Através dessas simulações foram gerados mapas superficiais de correntes para observar os diferentes padrões de circulação, pois o uso de modelos têm tido um papel relevante no planejamento e na elaboração de cenários alternativos, que englobam o diagnóstico adequado dos sistemas hídricos em sua estruturação, processo e dinâmica. Os parâmetros estudados mostraram variações durante os períodos de menor e de maior precipitação pluviométrica, sendo encontrados maiores contribuição no ponto 2 em relação a turbidez, a cor, o oxigênio dissolvido, nitrato, nitrogênio total, clorofila a e sólidos suspensos. Os demais parâmetros (N-amoniacal, demanda bioquímica de oxigênio e fósforo total) tiveram contribuição nos pontos 1 e 3, indicando fonte de poluição orgânica, decorrente de efluentes domésticos, já que nas proximidades ocorre lançamento de esgotos. No balanço de massa foi constatado que tanto o fósforo total quanto nitrogênio inorgânico dissolvido foram influenciados pela carga de água do rio Guamá durante o período seco. Enquanto que com altos índices de pluviosidade, o fósforo total teve carga maior devido a maior contribuição da drenagem de água de esgotos lançados para dentro do reservatório. O tempo de retenção para o fósforo total foi de 180 dias e o nitrogênio inorgânico dissolvido foi de 536 dias. Através desse balanço foi possível quantificar a entrada, retenção e exportação de nutrientes como também avaliar o potencial de eutrofização desse reservatório. No modelo hidrodinâmico mostrou que a distribuição do módulo da velocidade foi idêntica para cada mês do ano, independente da direção do vento, tendo a mata ciliar em torno desse ambiente hídrico importante papel na diminuição da velocidade modular na superfície da água. Porém próximo ao canal de saída de água do lago foi observada variação da velocidade de 0,32 m/s no período chuvoso e de 0,28 m/s no período seco, o que pode estar relacionada com as precipitações. Além disso, a entrada de água no reservatório forma vórtice tendendo ao processo de assoreamento, fato esse verificado na batimetria. Os processos de assoreamento nesse ponto se dão principalmente nos períodos com menores precipitações, pois a COSANPA aumenta as vazões de entrada de água para manter o nível do reservatório para o abastecimento da Região Metropolitana de Belém, propiciando o maior aporte de sedimentos suspensos, fato esse observado através dos parâmetros de turbidez, cor e sólidos suspensos, os quais tiveram maiores concentrações nesse ponto e uma diminuição à medida que se afastava para o ponto 3 (saída de água para o canal de ligação). Essas ferramentas são de grande importância para preservação do manancial, pois possibilitarão diagnosticar a capacidade que o lago tende a reter e eliminarem os nutrientes, bem como ao processo de circulação hidrodinâmica permitindo verificar locais que podem ter uma maior e menor deposição de materiais suspensos na coluna d’água. Esse estudo permitirá fornecer dados que subsidie as autoridades competentes e ajudará na conservação de outros mananciais utilizados para o abastecimento de água para as cidades. / The springs of Utinga, formed by the Bolonha and Água Preta lakes, are contained in an Área de Proteção Ambiental - APA and are used by the Companhia de Saneamento do Pará - COSANPA, to supply the population of the Região Metropolitana de Belém - RMB. These springs are formed by Guamá River, where water is captured and sent to the Água Preta lake by pumping, which in an artificial channel with gravity flow, feeds the Bolonha lake, and since it is pumped to the Estação de Tratamento de Água - ETA. The main problems of pollution / contamination of water sources appeared to advancing urban disordered, giving rise to the improper release of sewage and solid waste from neighborhoods, slums and housing estates close to the main springs. The objective of this study was to use tools to support monitoring and knowledge of water quality in the Água Preta lake, to prevent and / or correct degradation processes. These tools are multivariate analysis of abiotic parameters and chlorophyll a, nutrient balance and hydrodynamic modeling aiming to observe the dispersion of sediment transport. Samples were collected in surface water at three points strategically chosen to assess the anthropogenic influence in the Água Preta lake and sediments that are suspended matter carried into the lake. The sampling points were georeferenced using GPS (GARMIN Model) and the sampling of surface water were performed with the Van Dorn bottle 2.5 L and transported to the Laboratório de Química Ambiental (LQA), located at the Universidade Federal Rural da Amazônia, for further analysis. Samples were collected during the months of March, May, June, August, September and October in 2010, coinciding with periods of higher and lower rainfall. The data of abiotic parameters and chlorophyll a were analyzed by methods of descriptive statistics and principal component analysis. Analyses were also carried out analysis of the mass balance of water and nutrients and adopted the use of hydrodynamic model of the modeling program SisBAHIA (Sistema Base de Hidrodinâmica Ambiental), aimed to mimic the hydrodynamic conditions of the Água Preta lake during a year. Through these simulations were generated maps of surface currents to observe the different patterns of movement, since the use of models have played an important role in planning and development of alternative scenarios that include the proper diagnosis of the water systems in its structure, process and dynamics. The parameters studied showed variations during periods of lower and higher rainfall, higher contribution being found in point 2 in respect of turbidity, color, DO, nitrate, NT, chlorophyll a and suspended solids were found larger contribution in points 2. The other parameters (N -ammonia, BOD and PT) had contribution in points 1 and 3, indicating a source of organic pollution, due to domestic sewage, since there are nearby dumping of sewage. In the mass balance was found that both the PT and NID were influenced by the load of water river Guamá during the lower rainfall. While with high rainfall total phosphorus load was higher due to higher contribution from dewatering of sewage released into the reservoir. The retention time for the PT was 180 days and 536 days was NID. Through this balance could quantify the entry, retention and export of nutrients as well as to evaluate the potential for eutrophication of reservoirs. In the hydrodynamic model showed that the distribution of the module speed was identical for each month of the year, regardless of wind direction, with the riparian vegetation around that water environment this important role in reducing the speed modular surface of the water. However near the output channel of pond water was observed a change of speed 0.32 m /s in the rainy season and 0.28 m / s during the dry period that can be related to the precipitation. Furthermore, the input of water in the tank forms a vortex tending to sedimentation process, a fact observed in the bathymetry. The sedimentation at this point be given especially in periods with lower precipitation, because COSANPA increases the flow of water intake to maintain the level of the reservoir to supply the Região Metropolitana de Belém, providing the greatest contribution of suspended sediment, a fact observed with the parameters of turbidity, color and suspended solids, which have higher concentrations at this point and a decrease as they move away to step 3 (water outlet channel for the connection). These tools are of great importance for maintenance of the spring, since they will allow diagnosing the lake capacity tends of retain and remove nutrients as well as the process of the hydrodynamic circulation allowing check sites that can have a major and minor deposition of materials suspended in water column. Through this study will provide data that subsidizes the competent authorities the future and help in the conservation of other sources used to supply water to cities.
66

Dinâmica de cianobactérias e cianotoxinas em um braço do reservatório da usina hidroelétrica Luiz Eduardo Magalhães e suas implicações para o abastecimento público de Palmas - TO

Silva, José Roberto Lins da January 2009 (has links)
O trabalho apresenta resultados de um estudo sobre a dinâmica de cianobactérias e cianotoxinas e suas relações com variáveis climáticas, bióticas e abióticas do braço do reservatório da usina hidroelétrica Luiz Eduardo Magalhães (UHE Lajeado), em Palmas, Tocantins. O reservatório abrange 626 km2, extensão de 172 km, volume operacional de 4,9.109 m3, tempo de residência da água de 24 dias e uma área de drenagem de 184.219 km². O objetivo principal do estudo foi conhecer a dinâmica espacial e temporal de cianobactérias e cianotoxinas, bem como as suas implicações para o abastecimento público. Os resultados demonstraram que o ponto amostrado no período entre julho e dezembro de 2008, através do estudo de perfil vertical (PVJD), apresentou condições meso-eutróficas, com circulação do tipo polimítica, com estratificação transitória no final do período de seca e isotermia no período chuvoso. Os estudos nictemerais 1 (NIC-1), realizado em 29 de setembro de 2008, e 2 (NIC-2), realizado em 23 de março de 2009, comportaram-se sob condições climatológicas distintas, apresentando o segundo estudo características limnológicas inversas a do primeiro, marcadas principalmente pelas intrusões via tributários. As principais variáveis que influenciaram o padrão de distribuição das cianobactérias no sistema para os estudos foram: climáticas (ventos, precipitação e temperatura); físicas (turbidez e circulação térmica), e químicas (fósforo reativo solúvel e fósforo total). Em relação ao índice de estado trófico - IET, o ambiente foi classificado como eutrófico, para os estudos NIC-1 e 2, e oscilando entre mesotrófico e eutrófico em PVJD. O segundo estudo compreendeu uma avaliação mensal, entre os meses de janeiro de 2006 e dezembro de 2008. Os resultados demonstraram que o ponto 1 se comportou como ambiente em estado de meso-eutrofia, com regime de mistura polimítico, durante o ano de 2008. Neste mesmo ano, a temperatura do ar e a radiação solar foram as variáveis climáticas melhor correlacionadas positivamente com as variações de cianobactérias. Durante os períodos de estiagem dos três anos monitorados o nitrogênio total e o fósforo total definiram os padrões de distribuição de cianobactérias no ponto 1, através de razões inferiores a 10:1. Este ponto comportou-se como ambiente lêntico no período de estiagem, sofrendo influências do reservatório, e como ambiente lótico no período chuvoso, sob influências de fluxos do ribeirão Taquarussu Grande. O estudo também detectou a formação de três florações de cianobactérias no período de estiagem dos anos de 2007 e 2008 no ponto 1. A maior densidade de cianobactérias foi evidenciada em novembro de 2007 (28600 cél.mL-¹). A maior concentração de cianotoxinas ocorreu em julho de 2008, (>2,0 μg.L-¹ de microcistinas), nos pontos 1 e 3. Em relação à viabilidade para abastecimento público, os resultados de turbidez e clorofila-a sugerem a dupla-filtração como sendo a tecnologia capaz de remover cerca de 73,33% destas variáveis. De maneira geral, os dados obtidos neste trabalho sugerem a elaboração de um programa de avaliação sistemática destas toxinas e seus potenciais produtores nos pontos 1, 3, e foz do braço no reservatório. A modelagem ecológica subsidiaria a visualização de cenários futuros, e consequentemente, colaboraria na garantia da qualidade da água produzida pela empresa de abastecimento, no uso desta água para consumo humano. / This paper presents results of the study on the dynamic of cyanobacteria and cyanotoxins and their relationship with climatic, biotic and abiotic variables in the hydroelectric Luiz Eduardo Magalhães, Palmas (Tocantins-Brazil) reservoir. The reservoir has 626 km², is 172 km long, operating volume 4,9.109 m³, residence time 24 days, and adrainage area of 184.219 km². The main objective was to study the spatial and temporal dynamics of cyanobacteria and cyanotoxins, as well as its implications for public supply. The results showed that, between July and December 2008, the vertical profile of the studied site (PVJD) was meso-eutrophic, a polymictic mixing regime with stratification at the end of the dry season in a transitional period, and isotherm in the rainy season. Diel studies 1 (NIC-1) and 2 (NIC-2) revealed distinct climatic conditions, showed characteristics opposite, mainly by advection of intrusions via tributaries. In both occasions the main variables that affected the pattern of distribution of cyanobacteria were wind, precipitation and temperature), physical (turbidity, residence time, thermal circulation, orthophosphate and total phosphorus. The sampled area was classified as eutrophic, for studies NIC-1 and 2, and ranged from mesotrophic and eutrophic in PVJD. The second study included a monthly assessment, between January 2006 and December 2008. The results showed that sampling station 1 behaved as a meso-eutrophic environment in 2008. In that same year, the air temperature and solar radiation were the climatic variables that correlated most positively with changes in cyanobacteria. During the dry periods for the three monitored years the total nitrogen and total phosphorus defined the distribution patterns of cyanobacteria dynamics in the sampling station 1. This sampling station behaved as a lentic habitat in the dry season, associated with the reservoir, and as lotic in the rainy season, associated with the river Taquarussu Grande. The study also detected the occurrence of three cyanobacterial blooms in the dry season of the years 2007 and 2008 in section 1. The highest density of cyanobacteria was found in November 2007 (28600 cell.mL-¹). The highest concentration of cyanotoxins occurred in July 2008, (<2.0 μg.L-¹ microcystins) in sampling stations 1 and 3. Regarding the feasibility of this area for public supply, the results suggested the adoption of conventional treatment system. However, some peculiarities of water quality suggested that dual-filtration would be more adequate, due to the incoming effluents of the sewage treatment station Aureny in the sampling station 1. Overall, the data obtained throughout this study points to the maintenance of another two years of systematic evaluation of these toxins and their potential producers form sampling points1 and 3 to the estuary of the arm in the reservoir. The hydrological modelling of future scenarios will help to evaluate this area as source of water for human supply.
67

Subsídios para o zoneamento da APA do Rio dos Bugres, Rio Negrinho - SC, com vistas ao aproveitamento de água para abastecimento público

Dalagnol, Evelise de Fatima Neppel January 2001 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Filosofia e Ciências Humanas / Made available in DSpace on 2012-10-18T08:49:20Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-25T23:22:18Z : No. of bitstreams: 1 178252.pdf: 34839072 bytes, checksum: fe2624f13d93e6192aa7366f9a55dfb0 (MD5) / A sub-bacia do rio dos Bugres, com 81,84 km2, está localizada no Município de Rio Negrinho, Planalto Norte de Santa Catarina. Trata-se de Área de Proteção Ambiental (APA) municipal, criada através do Consórcio Quiriri, em 1998, visando ao futuro abastecimento público de água potável. Este trabalho tem como objetivo fornecer subsídios para o zoneamento ecológico-econômico, através do mapeamento do uso do solo da área da sub-bacia, da análise da qualidade e da disponibilidade de água do rio dos Bugres. O balanço hídrico calculado com dados de precipitação pluviométrica no período de 1991 a 2000 acusa deficiência de água no mês de abril e, de modo subordinado, em novembro, quando o cálculo é feito anualmente; este fato que é mascarado quando o cálculo é realizado pelas médias dos meses. As medidas de vazão também confirmaram a menor disponibilidade de água em abril, contrastando com a de janeiro. Adotando-se a paisagem como conceito norteador do trabalho, foi realizado um resgate histórico do processo de ocupação da área, com ênfase no uso do solo em 1978 e em 2000, na escala 1:50.000. Constatou-se que na sub-bacia ocorreu um grande aumento de reflorestamento de Pinus sp., em detrimento, principalmente, da Floresta de Araucária. Ficou evidente que a qualidade da água é influenciada negativamente pela criação de gado, pela realização do rodeio e pela presença de efluentes urbanos. O lixão, a retirada de mata ciliar, o uso de agrotóxicos nas lavouras e a poluição do ar também são problemas ambientais presentes na área. Entrevistas realizadas com os moradores demostram que até aquele momento havia pouca informação sobre o que representa uma APA, embora a grande maioria demostrasse interesse em participar de projetos que visem à proteção da área. Entretanto, trabalhos mais detalhados poderão dar maiores informações sobre o impacto da monocultura de Pinus sp. e das demais atividades agropecuárias sobre a água, bem como determinar o melhor ponto para a captação de água
68

Dinâmica de cianobactérias e cianotoxinas em um braço do reservatório da usina hidroelétrica Luiz Eduardo Magalhães e suas implicações para o abastecimento público de Palmas - TO

Silva, José Roberto Lins da January 2009 (has links)
O trabalho apresenta resultados de um estudo sobre a dinâmica de cianobactérias e cianotoxinas e suas relações com variáveis climáticas, bióticas e abióticas do braço do reservatório da usina hidroelétrica Luiz Eduardo Magalhães (UHE Lajeado), em Palmas, Tocantins. O reservatório abrange 626 km2, extensão de 172 km, volume operacional de 4,9.109 m3, tempo de residência da água de 24 dias e uma área de drenagem de 184.219 km². O objetivo principal do estudo foi conhecer a dinâmica espacial e temporal de cianobactérias e cianotoxinas, bem como as suas implicações para o abastecimento público. Os resultados demonstraram que o ponto amostrado no período entre julho e dezembro de 2008, através do estudo de perfil vertical (PVJD), apresentou condições meso-eutróficas, com circulação do tipo polimítica, com estratificação transitória no final do período de seca e isotermia no período chuvoso. Os estudos nictemerais 1 (NIC-1), realizado em 29 de setembro de 2008, e 2 (NIC-2), realizado em 23 de março de 2009, comportaram-se sob condições climatológicas distintas, apresentando o segundo estudo características limnológicas inversas a do primeiro, marcadas principalmente pelas intrusões via tributários. As principais variáveis que influenciaram o padrão de distribuição das cianobactérias no sistema para os estudos foram: climáticas (ventos, precipitação e temperatura); físicas (turbidez e circulação térmica), e químicas (fósforo reativo solúvel e fósforo total). Em relação ao índice de estado trófico - IET, o ambiente foi classificado como eutrófico, para os estudos NIC-1 e 2, e oscilando entre mesotrófico e eutrófico em PVJD. O segundo estudo compreendeu uma avaliação mensal, entre os meses de janeiro de 2006 e dezembro de 2008. Os resultados demonstraram que o ponto 1 se comportou como ambiente em estado de meso-eutrofia, com regime de mistura polimítico, durante o ano de 2008. Neste mesmo ano, a temperatura do ar e a radiação solar foram as variáveis climáticas melhor correlacionadas positivamente com as variações de cianobactérias. Durante os períodos de estiagem dos três anos monitorados o nitrogênio total e o fósforo total definiram os padrões de distribuição de cianobactérias no ponto 1, através de razões inferiores a 10:1. Este ponto comportou-se como ambiente lêntico no período de estiagem, sofrendo influências do reservatório, e como ambiente lótico no período chuvoso, sob influências de fluxos do ribeirão Taquarussu Grande. O estudo também detectou a formação de três florações de cianobactérias no período de estiagem dos anos de 2007 e 2008 no ponto 1. A maior densidade de cianobactérias foi evidenciada em novembro de 2007 (28600 cél.mL-¹). A maior concentração de cianotoxinas ocorreu em julho de 2008, (>2,0 μg.L-¹ de microcistinas), nos pontos 1 e 3. Em relação à viabilidade para abastecimento público, os resultados de turbidez e clorofila-a sugerem a dupla-filtração como sendo a tecnologia capaz de remover cerca de 73,33% destas variáveis. De maneira geral, os dados obtidos neste trabalho sugerem a elaboração de um programa de avaliação sistemática destas toxinas e seus potenciais produtores nos pontos 1, 3, e foz do braço no reservatório. A modelagem ecológica subsidiaria a visualização de cenários futuros, e consequentemente, colaboraria na garantia da qualidade da água produzida pela empresa de abastecimento, no uso desta água para consumo humano. / This paper presents results of the study on the dynamic of cyanobacteria and cyanotoxins and their relationship with climatic, biotic and abiotic variables in the hydroelectric Luiz Eduardo Magalhães, Palmas (Tocantins-Brazil) reservoir. The reservoir has 626 km², is 172 km long, operating volume 4,9.109 m³, residence time 24 days, and adrainage area of 184.219 km². The main objective was to study the spatial and temporal dynamics of cyanobacteria and cyanotoxins, as well as its implications for public supply. The results showed that, between July and December 2008, the vertical profile of the studied site (PVJD) was meso-eutrophic, a polymictic mixing regime with stratification at the end of the dry season in a transitional period, and isotherm in the rainy season. Diel studies 1 (NIC-1) and 2 (NIC-2) revealed distinct climatic conditions, showed characteristics opposite, mainly by advection of intrusions via tributaries. In both occasions the main variables that affected the pattern of distribution of cyanobacteria were wind, precipitation and temperature), physical (turbidity, residence time, thermal circulation, orthophosphate and total phosphorus. The sampled area was classified as eutrophic, for studies NIC-1 and 2, and ranged from mesotrophic and eutrophic in PVJD. The second study included a monthly assessment, between January 2006 and December 2008. The results showed that sampling station 1 behaved as a meso-eutrophic environment in 2008. In that same year, the air temperature and solar radiation were the climatic variables that correlated most positively with changes in cyanobacteria. During the dry periods for the three monitored years the total nitrogen and total phosphorus defined the distribution patterns of cyanobacteria dynamics in the sampling station 1. This sampling station behaved as a lentic habitat in the dry season, associated with the reservoir, and as lotic in the rainy season, associated with the river Taquarussu Grande. The study also detected the occurrence of three cyanobacterial blooms in the dry season of the years 2007 and 2008 in section 1. The highest density of cyanobacteria was found in November 2007 (28600 cell.mL-¹). The highest concentration of cyanotoxins occurred in July 2008, (<2.0 μg.L-¹ microcystins) in sampling stations 1 and 3. Regarding the feasibility of this area for public supply, the results suggested the adoption of conventional treatment system. However, some peculiarities of water quality suggested that dual-filtration would be more adequate, due to the incoming effluents of the sewage treatment station Aureny in the sampling station 1. Overall, the data obtained throughout this study points to the maintenance of another two years of systematic evaluation of these toxins and their potential producers form sampling points1 and 3 to the estuary of the arm in the reservoir. The hydrological modelling of future scenarios will help to evaluate this area as source of water for human supply.
69

Influencia de processos naturais e tecnogenicos na qualidade de águas superficiais de Blumenau-SC

Percebon, Claudete Massuchin January 2003 (has links)
Apendices / Anexo / Orientador: André de Virmond Lima Bittencourt / Co-orientador: Ernani F. da Rosa Filho / Dissertaçao (mestrado) - Universidade Federal do Paraná / Resumo: Esse e um estudo sobre a qualidade das águas superficiais de Blumenau - SC, desenvolvido dentro de um programa de amostragens e analises que se estendeu por 24 meses, entre junho e 2000 a agosto de 2002. Fazem parte dessa avaliação os principais rios desse Município, a saber: o trecho do Itajai-Acu, que divide a cidade, e seus tributários. Na sua margem direita, o Garcia e o da Velha; e em sua margem esquerda: o do Testo, Itoupava e Fortaleza. Foram avaliados os resultados de 15 parâmetros fisicoquimicos diferentes, analisados nas águas desses rios. Fez-se o levantamento de informações da micro-região, como condições climáticas, topográficas, hidrográficas, geológicas, geomorfológicas, de uso do solo, do potencial poluidor das atividades econômicas locais, pedológicas e agropecuárias, entre outras. Foi confrontada a resposta de cada rio, segundo o resultado da qualidade de suas águas, aos fatores ambientais locais, esse foi um dos objetivos do presente estudo. O uso atual e futuro dessas águas superficiais, correspondentes a rede potamografica estudada, seja para abastecimento publico, seja com finalidades turísticas ou de preservação ambiental, foi a justificativa para o estudo. Como principais conclusões desse estudo tem-se: a temperatura se mostrou um parâmetro de controle muito importante na avaliação da qualidade das águas superficiais; a condutividade foi o parâmetro mais fiel a qualidade da águas; a presença de mata ciliar nos rios e cobertura vegetal nas micro-bacias estudadas se mostraram como fatores positivos na qualidade das águas; a chuva evidenciou arrastar nutrientes para os rios em áreas mais expostas; o substrato drenado apresentou significativa correlação com a presença de cor, baixo pH e sólidos totais em diferentes pontos estudados; a correlação entre os parâmetros e maior para águas de melhor qualidade; o método do IQA simplificado desenvolvido permitiu analisar a qualidade dos rios estudados. A metodologia desenvolvida nesse diagnostico, os mapas elaborados, as informações compiladas e as conclusões aqui apontadas, poderão ser uteis nos trabalhos de monitoramento e preservação da qualidade dos rios da área, ou servirem de apoio a outras pesquisas ou estudos correlatos desenvolvidos na região. Palavras-chave: Qualidade de Águas de Rios; Fatores Ambientais; Parâmetros Físicos, Químicos e Bacteriológicos. / Abstract: This is a study about Blumenau's, Santa Catarina State, surface water quality, using a sampling and analyses program extended for twenty-four months. Including in this assessment the main streams of municipal district area, such: the Itajai-Agu, on its portion, on the passage through Blumenau City, and its tributaries. On its right margin, the Garcia stream, and da Velha stream. On its left margin, the Testo stream, Itoupava stream and Fortaleza stream. Were evaluated fifteen physical-chemistry distinct parameters, developed on the waters from these streams. The micro-region knowledge like the climate conditions, the topography, the hydrology, the geology, the geomorphology, the soil use, the pollution potential from local economical and agricultural activities, and others aspects, was realized. The water quality answer to these subjects was pondered for each stream. It was developed a particular water quality index to evaluate the surface water studied. The head conclusions of this study was: the temperature was showed like a important control parameter on the superficial water evaluation; the parameter conductivity offers the better answer to the water quality; the riparian zone and basin vegetable coverage was positives aspects on superficial waters quality; the rain falls over exposed areas can to induce nutrients to the superficial waters; the answers of the subsurface drained on the streams waters can be watched in the pH, total solids and apparent color parameters; the best relationships between parameters was noted in the better quality waters; the simplified method of Water Quality Index allowed to define the studied streams quality.To know the local streams water quality and make the correlation with theirs environments is one of purposes of this work. The real and future use of regional surfaces waters was an apology of this study. The developed methodology used to this diagnosis, the maps elaborated, the data and conclusions here pointed, could be useful on the works to keeping and preserving regional waters rivers quality. Key-words: River Water Quality; Environmental Assessments; Physics, Chemicals and Bacteriological Parameters.
70

Remoção de nitrogênio de água residuária de produção intensiva de tilápias com recirculação utilizando reator de leito fluidizado com circulação em tubos concêntricos

Sánchez Ortiz, Iván Andrés [UNESP] 17 August 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:13Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-08-17Bitstream added on 2014-06-13T19:38:25Z : No. of bitstreams: 1 sanchezortiz_ia_me_ilha.pdf: 1847784 bytes, checksum: c206c32f94a2aa37f63cc5e192dfd7c6 (MD5) / Fundação de Ensino Pesquisa e Extensão de Ilha Solteira (FEPISA) / O presente projeto de pesquisa avaliou o desempenho de remoção de nitrogênio num sistema de tratamento biológico das águas residuárias de produção intensiva de Tilápia Nilótica com recirculação utilizando decantador horizontal e um reator aeróbio de leito fluidizado com circulação em tubos concêntricos. Utilizou-se como material suporte carvão ativado granular com densidade aparente de 1,64g/cm3 e tamanho efetivo de 0,34mm numa concentração de 80g/L. Foram avaliadas as velocidades de circulação e as expansões de quatro configurações de reatores com diâmetro externo constante de 250mm e diâmetros internos variáveis de 100, 125, 150 e 200mm. O reator utilizado no sistema de tratamento possui um volume efetivo de 113L e diâmetro interno de 100mm. O sistema foi inoculado durante três semanas com água do Lago do Ipê do município de Ilha Solteira SP e foi feita a avaliação ao longo de oito semanas com reposição semanal de 55% do volume total de água do sistema; o período de detenção hidráulica no reator foi de 11,9 minutos. Durante o projeto foram monitorados os seguintes parâmetros: sólidos totais, suspensos voláteis e fixos, cor aparente, OD, pH, condutividade, temperatura, potencial redox, amônia, amônio, turbidez, DQO, DBO, nitrogênio total, fósforo total. Os resultados mostraram que as remoções médias de nitrogênio amoniacal total, DBO, DQO, fósforo e nitrogênio total foram de 27%, 47%, 75%, 38% e 24% respectivamente. O sistema de tratamento avaliado mostrou-se como uma alternativa efetiva para o reuso da água no sistema de recirculação capaz de manter as características de qualidade da água dentro dos valores recomendáveis para criação das Tilápias e dos valores permitidos pela legislação brasileira para lançamento de efluentes com exceção do fósforo. / This research project evaluated the nitrogen removal efficiency in a biological treatment system of an intensive Nile Tilapia laboratory facility with recirculation by a rectangular sedimentation tank and a three phase aerobic fluidized bed internal-loop airlift reactor. Granular activated carbon was used as support particles with density of 1,64g/cm3 and effective size of 0,34mm in a concentration of 80g/L. Liquid circulation velocities and gas holdup were evaluated in four different reactor configurations with a 250mm constant external diameter and internal variable diameters of 100, 125, 150 and 200mm. On the evaluated reactor the effective volume was 113L and the internal diameter 100mm. The system was inoculated during three weeks with natural water from Ipê Lake localized in Ilha Solteira’s SP municipality and was evaluated in an eigth week period with a 55% weekly total water exchange rate; reactor´s hydraulic detention time was 11,9 minutes. During the study were measured the next parameters: total, suspended, volatile and fixed solids, apparent color, DO, pH, conductivity, temperature, oxidation reduction potential, ammonia, turbidity, COD, BOD, total nitrogen, total phosphorous. Results showed that average removal rates of total ammonia nitrogen, BOD, COD, phosphorus and total nitrogen were 27%, 47%, 75%, 38% and 24% respectively. Evaluated treatment system showed as an effective alternative for water reuse in the recirculation system capable of maintain water quality characteristics within the recommended values for fish farming and meeting the Brazilian standards for final effluent discharges with exception of phosphorous values.

Page generated in 0.1012 seconds