• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 74
  • Tagged with
  • 74
  • 74
  • 34
  • 30
  • 26
  • 21
  • 16
  • 16
  • 14
  • 14
  • 11
  • 9
  • 9
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação in vitro (30 dias) da resistência de união de sistemas adesivos autocondiconantes a dentina

Carvalho, Luana Dutra de January 2004 (has links)
Disseratação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciência da Saúde. Programa de Pós-graduação em Odontologia. / Made available in DSpace on 2012-10-20T16:24:13Z (GMT). No. of bitstreams: 1 203100.pdf: 2302178 bytes, checksum: 1200f4996c46a0c43d8af6c68ccda1ae (MD5) / O objetivo deste trabalho foi avaliar a resistência de união sob cisalhamento de cinco sistemas adesivos à dentina (30 dias), assim como avaliar a interface dentina/ sistema adesivo. Terceiros molares humanos recém-extraídos por razões diversas foram utilizados. Os espécimes foram divididos aleatoriamente em cinco grupos (n=15), de acordo com o sistema adesivo utilizado: Grupo I (controle): Optibond Solo Plus (Sybron Kerr), Grupo II: Optibond Solo Plus SE (Sybron Kerr) Grupo III: Tyrian SPE/One Step Plus; Grupo IV: Clearfil SE Bond (Kuraray) e Grupo V: Adper Prompt (3M ESPE). Os corpos-de-prova foram armazenados a 37°C, em água destilada, durante um período de 30 dias. Em seguida, o ensaio de cisalhamento foi realizado em uma máquina de Testes Universal INSTRON (Modelo 4444), com uma velocidade de 0.75 mm/min. As interfaces dentina/ adesivo foram analisadas em Microscopia Eletrônica de Varredura e o material representativo foi fotografado. A análise estatística revelou diferenças significativas entre as médias, que foram comparadas entre si pelo teste ANOVA e comparativo de Tukey. Os valores médios de resistência ao cisalhamento foram de 34,3 MPa (Optibond Solo Plus), 25 MPa (Optibond Solo Plus SE), 14,8 MPa (Tyrian SPE), 30,2 MPa (Clearfil SE Bond) e 20,2 MPa (Adper Prompt). Concluiu-se que os sistemas adesivos autocondicionantes testados apresentaram a seguinte ordem decrescente de resistência de união: Clearfil SE Bond ? Optibond Solo Plus SE ? Adper Prompt ? Tyrian SPE, sendo todas as médias menores que o grupo controle. Não houve diferença estatística entre o Optibond Solo Plus e Clearfil SE Bond.
12

Adesão à dentina

Lopes, Guilherme Carpena January 2003 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-20T20:55:16Z (GMT). No. of bitstreams: 0 / O objetivo foi verificar se há diferença na capacidade de união ao substrato dentinário envelhecido quando comparado com o jovem; e, se o aumento do tempo de condicionamento poderá resultar em uma maior resistência de adesão a este substrato envelhecido, sem prejudicar a união ao substrato jovem. Foram realizados testes de resistência de união, verificação da dureza dentinária e microscopia eletrônica de varredura da interface adesiva. A dentina envelhecida condicionada por 15s obteve resistência de união estatisticamente menor que todos os outros grupos. A dureza da dentina envelhecida foi maior do que a dentina jovem. O maior conteúdo mineral na dentina envelhecida dificulta a união, resultando em mais baixa m-TBS quando o condicionamento é feito por apenas 15s. Por outro lado, a duplicação do tempo de condicionamento resulta em mais adequada adesão à dentina envelhecida alcançando médias similares à dentina jovem.
13

Adesão dentinária

Lopes, Guilherme Carpena January 2002 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-19T15:22:08Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-26T02:23:49Z : No. of bitstreams: 1 182036.pdf: 3278352 bytes, checksum: 6cdb9d1374e1b01992564a73a044a65b (MD5) / Objetivos: verificar a capacidade de união ao substrato dentinário hipermineralizado com dois tempos de condicionamento ácido. Material e métodos: Trinta molares humanos com cáries oclusais crônicas foram cortados transversalmente, polidos até lixa 600, expondo a dentina esclerótica na porção central. O ácido fosfórico 35% (3M) foi usado por 15s ou 30s, e o sistema SingleBond+Z250(3M) foram aplicados. Depois de 24 h em água, os dentes foram cortados em duas direções perpendiculares com um disco diamantado para obter-se os filetes com uma seção de aprox. 0.7mm2 (n=25). Um exame visual foi conduzido para dividir os filetes em dois grupos: dentina esclerótica (G15E e G30E) e normal (G15N e G30N). Os filetes foram colados em um dispositivo (Bencor) e a resistência de união por microtração (m-TBS) foi medida. Os dados foram analisados por ANOVA 2 e teste t. A dureza Knoop (KHN) da porção dentinária de todos os filetes foi medida e os dados entre a dentina esclerótica e normal foram comparados com teste t. Resultados: As médias (±DP) de m-TBS foram: G15E=56,4(±14,9), G15N=69,7(±17,2), G30E= 63,2(±15,6) e G30N=67,7(±13,3). O teste t mostrou que G15N apresentou superior m-TBS quando comparado com G15E (p=0,0016). ANOVA 2 mostrou que a m-TBS na dentina normal foi maior do que na esclerótica. A dureza da dentina esclerótica foi maior do que na normal. Conclusões do experimento: O maior conteúdo mineral na dentina esclerótica dificulta a união a este substrato, resultando em mais baixa m-TBS. Mas, a duplicação do tempo de condicionamento resulta em uma m-TBS similar à dentina normal.
14

Avaliação in vitro da resistência de união de dois sistemas adesivos dentinários à dentina bovina antes e após a termociclagem: teste de cisalhamento e análise estereomicroscópia

Amendola, Alessandra Buhler [UNESP] 03 December 1999 (has links) (PDF)
Made available in DSpace on 2015-12-10T14:22:33Z (GMT). No. of bitstreams: 0 Previous issue date: 1999-12-03. Added 1 bitstream(s) on 2015-12-10T14:28:41Z : No. of bitstreams: 1 000125689.pdf: 4542822 bytes, checksum: adb0f42e1dcec6f525aa88704508a7b7 (MD5) / O objetivo do presente estudo foi o de avaliar e comparar a efetividade da união de dois sistemas adesivos: Scotchbond Multi-Uso Plus (3M) e Etch & Prime 3.0 (Degussa) à dentina bovina antes e após a termociclagem, bem como o de avaliar o tipo de fratura ocorrido na interface dentina/material. Empregaram-se dentes bovinos, que tiveram a superfície vestibular desgastada com lixas de papel de granulação crescente para a exposição da dentina. Os espécimes foram divididos em dois grupos, nos quais aplicou-se os sistemas adesivos e, posteriormente, a resina composta Z100 (3M) por meio de uma matriz de teflon com 4mm de diâmetro. Estes grupos foram subdivididos em dois subgrupos (A e B). O subgrupo A foi submetido ao ensaio mecânico de cisalhamento após 24h e o subgrupo B recebeu a ciclagem térmica, que consistiu de quinhentos ciclos entre 5°C e 55°C, com duração de 30s em cada temperatura, para depois ser submetido ao teste de cisalhamento. O ensaio mecânico foi realizado em máquina lnstron Universal à velocidade de 0,5mm/min. As superfícies fraturadas foram analisadas em estereomicroscópio (Karl Zeiss). A aplicação do teste estatístico ANOVA, ao nível de significância de 0,05, revelou que os valores de resistência de união dos dois sistemas adesivos avaliados não apresentaram diferença estatisticamente significativa e que a utilização da termociclagem não influenciou a resistência adesiva dos materiais testados. O Scotchbond Multi-Uso Plus apresentou predominância de falhas adesivas e o Etch & Prime 3.0 apresentou maior quantidade de fraturas mistas, seguidas pelas fraturas adesivas / The aim of fhe present study was to investigate the shear bond strength of two adhesive systems, Scotchbond Multi-Purpose Plus (3M) and Etch & Prime 3.0 (Degussa), to bovine dentin, before and after thermal cycling. Bovine incisors were embedded in self-cured resin and labial dentin surfaces were ground with sequential abrasive sandpapers. The specimens were separated into two groups to receive the adhesive systems. A composite resin cylinder (Z100-3M) was bonded to the dentinal surface. The two groups were divided into two more groups (A and B). The subgroup A was shear tested after 24h and the subgroup B was subjected to 500 thermal cycles, between 5ºC and 55ºC, with a dwell time of 30 seconds and, then, shear tested. The bond strength was performed on a Universal lnstron machine 4301, with a load cell of 500 Kg and a speed of 0,5mm/min. The mode of failure were classified. The analysis of variance (ANOVA), at 5% significant level, revealed that there were no significant differences among the bond strength of the two adhesive systems, and that the thermal cycling did not significantly influence strength of the two materials tested. The Scotchbond Multi-Purpose Plus showed a considerable number of adhesive failures and the Etch & Prime 3.0 showed predominantly mixed fractures, followed by adhesive fractures
15

Propriedades mecânicas, físico-químicas e biológica de adesivo experimental com incorporação de epigalocatequina-3-galato

Fonseca, Beatriz Maria da [UNESP] 29 October 2015 (has links) (PDF)
Made available in DSpace on 2016-04-01T17:54:43Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-10-29. Added 1 bitstream(s) on 2016-04-01T18:00:23Z : No. of bitstreams: 1 000860767.pdf: 2569580 bytes, checksum: 600ad569f5d136f8f08c32289c8f1af4 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo desse estudo foi avaliar o efeito da adição de EGCG em adesivo experimental na manutenção da camada híbrida, avaliando suas propriedades mecânicas, físico-químicas e biológica. A primeira etapa do estudo envolveu a manipulação do adesivo com incorporação de EGCG (0,5%, 1,0% e 1,5%) na relação BisGMA 55% / HEMA 45%, canforoquinona 0,5% e DMAEMA 0,5%. O grau de conversão (GC) dos monômeros foi avaliado por Espectroscopia micro-Raman (GC : EGCG 1.5 - 99,11a; EGCG 1.0 - 99,02a; EGCG 0.5 - 96,58ab; Controle - 85,47b). A segunda etapa envolveu a realização de análises mecânicas e físico-químicas [resistência flexural (RF) e módulo de elasticidade (ME); módulo de resiliência (RE) e resistência a compressão(RCo); sorção (A) e solubilidade (S) em água; contração de polimerização (CP)]; teste de resistência à microtração (RA) imediato (24 h) e longitudinal (6 meses); e teste biológico [ensaio de citotoxicidade (CI)]. Os resultados foram: RF, ME, RE, RCo e CP não apresentaram diferença significativa entre os grupos. Os testes de A e S apresentaram redução dos valores para os grupos EGCG 0.5 e 1.0; RA imediato (24 h) não apresentou diferença entre os grupos. Após 6 meses houve redução dos valores somente para os grupos Controle e EGCG 1.5, os grupos EGCG 0.5 e 1.0 mantiveram os valores de RA constantes. CI: a incorporação de EGCG aumentou a viabilidade celular nas diluições de 0,1% e 1,0%, comparado ao grupo Controle. Pôde-se concluir que a incorporação de EGCG independente da concentração não afetou o GC. As concentrações de 0,5% (100 μg/ml) e 1,0% (200 μg/ml) em volume de EGCG é capaz de preservar a camada híbrida formada e prorrogar a longevidade das restaurações em resina composta, além de aumentar a viabilidade celular / The aim of this study was to evaluate the effect of EGCG in an experimental adhesive to reduce the hybrid layer degradation, through mechanical, physical-chemical and biological analysis. The first step of this study involved manipulation of the adhesive model with the incorporation three different concentrations of EGCG (0.5%, 1.0% and 1.5%) in relation BisGMA 55% / 45% HEMA, 0.5% camphorquinone and 0.5% DMAEMA. The conversion degree (DC) of adhesive monomers was evaluated by micro-Raman spectroscopy (GC: EGCG 1.5 (1.5%) - 99,11a; EGCG 1.0 (1.0%) - 99,02a; EGCG 0.5 (0.5%) - 96,58ab; Control - 85,47b). The second step involved the mechanical and physicochemical analysis [flexural strength (FS) and elastic modulus (EM); resiliency modulus (RM) and compressive bond strength (CBS), sorption (A) and solubility (S) in water; shrinkage polymerization (SP)]; microtensile bond strength test (μTBS) immediately (24 h) and longitudinal (6 months) and biological analyze [cytotoxicity assay (CY)]. The results were: FS, EM, RM, CBS and SP showed no significant difference between groups; A and S tests showed reduced values only for EGCG 0.5 and 1.0 groups. RA immediately (24) did not differ between groups. After six months there was a reduction of the values only for the control and EGCG 1.5 groups, EGCG groups 0.5 and 1.0 maintained the RA values. CY: EGCG incorporation increased the cell viability in 0.1% and 1.0% dilutions compared to the control group. It was concluded incorporation of EGCG at 0.5, 1.0 and 1.5 concentrations did not affect the degree of conversion of the monomers. Thus, the incorporation of 0.5% (100 μg/ml) and 1.0% (200 μg/ml) EGCG amount can preserve the hybrid layer formed and prolong longevity composite resin restorations in addition to increasing cell viability.
16

Avaliação da resistência de união ao cisalhamento, de diferentes sistemas adesivos à dentina. Análise em MEV do infiltrado resinoso

Quagliatto, Paulo Sérgio [UNESP] 10 December 2001 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:27Z (GMT). No. of bitstreams: 0 Previous issue date: 2001-12-10Bitstream added on 2014-06-13T19:20:27Z : No. of bitstreams: 1 quagliatto_ps_dr_arafo.pdf: 1690792 bytes, checksum: c0676d0303727f92ee07518d6edd37d9 (MD5) / Foi avaliada in vitroa resistência de união ao cisalhamento de seis sistemas adesivos à dentina, e também, análise microscópica (MEV) do infiltrado resinoso.Para tanto, noventa terceiros molares humanos, hígidos e erupcionados foram selecionados, sendo setenta e dois utilizados para os testes mecânicos e dezoito para análise microscópica.Inicialmente setenta e dois molares tiveram suas superfícies oclusais desgastadas, até completa eliminação do esmalte e total exposição da área dentinária, sendo incluídos em matriz bi-partida com gesso especial. Após a superfície dentinária ter sido submetida a ação de lixas d'água de granulação decrescente, os corpos de prova (doze por grupo) receberam de acordo com as recomendações dos fabricantes, a aplicação dos sitemas adesivos dentinários: G1-SE BOND; G2- ABF BOND; G3- PRIME & BOND NT; G4- SINGLE-BOND;G5-TENURE QUICK FLUORIDE e G6-GLUMA CONFORT BOND DESSENSITIZER; sendo posteriormente acoplados em Aparatus Ultradent que possue uma matriz de teflon com diâmetro de 2,35 mm de raio onde uma resina composta (P60-3M Dental Produc.) foi compactada pelo orifício da matriz e fotopolimerizada seguindo o protocolo do fabricante. Obteve-se assim um cilindro de resina composta que manteve-se aderido a superfície dentinária. Os corpos de prova foram submetidos a termociclagem (500x,5-55°C) , armazenados em água destilada a 37°C por 48 horas e fixados em máquina de ensaio universal Instron/MTS para os testes de cisalhamento.Os valores médios de resistência de união, em Mpa, para os grupos foram: G1 -22.9 l 4.3; G2 -23.9 l 3.2; G3 -18.0 l 2.2; G4 -25.0 l 4.9; G5 -23.5 l 4.7 e G6 -22.7 l 3.2. ANOVA, a nível de significância p<0.05, apresentou diferenças significantes. SNK para comparação entre os grupos mostrou diferenças significantes entre os grupos, 1 vs 3, 2 vs 3, 4... . / To evaluate the resin-dentin interfacial morphology and shear bond strength to dentin of several new self-etching primers and experimental dentin bonding systems and one-bottle enamel-dentin adhesives. Seventy-two healthy human molars were selected. Flat occlusal surfaces were made with a series of SiC paper into the superficial-to-middle dentin. The following groups were established (12 teeth per group): (G1) SE Bond; (G2) Experimental ABF Bond; (G3) Prime & Bond NT; (G4) Single-Bond; (G5) Tenure Quick F and (G6) Gluma Comfort Bond + Desensitizer. For all groups P60 (3M) resin-based composite was used. All adhesives were handled according to the manufacturers' instructions. Immediately after bonding, the specimens were stored in water for 48 hrs and then thermocycled (500x, 5-55°C). Specimens were sheared at a crosshead speed of 1 mm/min in an Instron / MTS machine. The results were analyzed with an ANOVA and Student-Newman-Keuls (SNK) test. All samples were treated with glutaraldehyde, 37% phosphoric acid, NaOCl, HCL, and gold-palladium to be inspected under SEM (Model 840A, JEOL). In MPa: (1) 22.9 l 4.3; (2) 23.9 l 3.1; (3) 18.0 l 2.2; (4) 25.0 l 4.9; (5) 23.5 l 4.7;(G6) 22.7 l 3.2. ANOVA showed a statistically significant difference (P< 0.05) among the groups. SNK test showed that groups 1 vs 3, 2 vs 3, 4 vs 3, 5 vs 3 and 6 vs 3 were statistically significantly different (P<0.05). SE Bond, Experimental ABF Bond, Single-Bond, Tenure Quick F and Gluma Comfort Bond + Desensitizer showed no significant differences among them, but were different from Prime-Bond NT. All adhesives systems produced resin-infiltrated dentin layer within intertubular dentin of resin tags by SEM. Bond strength did not correlate well with the thickness and morphology of resin-infiltrated dentin layer.
17

Abordagens estatísticas em testes de resistência de união entre dentina bovina, sistema adesivo e resina composta

Balducci, Ivan [UNESP] 25 April 2014 (has links) (PDF)
Made available in DSpace on 2015-09-17T15:24:22Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-04-25. Added 1 bitstream(s) on 2015-09-17T15:47:55Z : No. of bitstreams: 1 000844174.pdf: 1728436 bytes, checksum: 6c4b793420a35ded6629f8099de66606 (MD5) / O objetivo deste estudo foi empregar diferentes abordagens estatísticas em dados obtidos em ensaios de micro e macrotração, em dois períodos de tempo de armazenamento, a fim de descrever e quantificar a variabilidade comumente encontrada nos testes de adesão. Foram selecionados 48 dentes bovinos. As raízes seccionadas a 2 mm abaixo da junção cementoesmalte e as faces vestibulares foram desgastadas expondo superfície de dentina plana. Os dentes foram embutidos em resina acrílica e aleatoriamente designados a quatro grupos (n = 12) para avaliação da resistência de união (RU). Para o teste de microtração foi aplicado o adesivo Adper Single Bond 2- (SE Bond 2- 3M-ESPE) numa área de 8 mm2, seguido de jato de ar por 2 a 5 s e fotopolimerização por 15 s e, a seguir, inserida a resina composta Z350 XT- (3 M-ESPE). Após 24 h de armazenamento, em água destilada a 37 ºC, para cada dente um número variável de palitos foi obtido. Doze dentes foram submetidos ao teste de microtração após 24 h (G1) e outros 12 submetidos à termociclagem (G2) seguido de microtração. Para a macrotração, a base menor dos espécimes cônicos foi de 2 mm. Doze amostras após 24 h foram submetidas ao teste de macrotração (G3) e as outras doze, após as 24 h, termocicladas (G4). Os dados foram submetidos a uma análise exploratória; seguidos de uma análise confirmatória (inferencial). A estatística descritiva e o resultado da análise de Weibull para os dados de RU (MPa) foram: G1(módulo; média ± desvio padrão: 2,54; 10,76 ± 4,21); G2 (3,36; 19,34 ± 6,42); G3 (1,96; 3,17 ± 1,51; G4 (1,75; 2,86 ± 1,68). O teste ANOVA (2-way), α = 5%, indica efeito interação significante e, os testes de Tukey e de Dunn (5%), complementaram os resultados. Pôde-se concluir: as diferentes estratégias estatísticas (análise de Weibull, análise exploratória e abordagem paramétrica) indicaram os mesmo resultados. Pode-se concluir: as diferentes... / The aim of this study was to use different statistical approaches on data obtained from micro and macrotensile tests in two periods of time storage, in order to describe and quantify the variability commonly found in adhesion tests. 48 bovine teeth were selected. The roots were sectioned 2 mm below the cement-enamel junction and the buccal surfaces were ground to exposure a dentin flat surface. The teeth were embedded in acrylic resin and randomly assigned to four groups (n = 12) to evaluate the bond strength (BS). For the microtensile test the adhesive Adper Single Bond 2 - (2 SE Bond - 3M - ESPE) was applied in an area of 8 mm2, followed by air jet during 2 to 5 s and curing for 15 s. Right after the XT - Z350 composite resin (3M ESPE) was inserted. After 24 h of storage in distilled water at 37 °C, for each tooth a variable number of sticks was obtained. Twelve teeth were submitted to microtensile test after 24 h (G1) and other 12 to thermocycling (G2) and microtensile test. For macrotensile, the smallest base of conical shape specimens was 2 mm. After 24 h twelve samples were subjected to macrontesile test (G3) and the other twelve, after 24 h, were thermocycled (G4). The data were submitted to an exploratory analysis, followed by a (inferential) confirmatory analysis. Descriptive statistics and the results of Weibull analysis for the data of BS (MPa) of the experimental conditions were: G1 (module; mean ± standard deviation: 2.54; 10.76 ± 4.21); G2 (3.36; 19.34 ± 6.42); G3 1.96; 3.17 ± 1.51; G4 (1.75; 2.86 ± 1.68). The ANOVA (2-way), α = 5%, indicated significant interaction effect, and Tukey tests and Dunn (5%), complemented the results. The conclusion is: the different statistics strategies (Weibull analysis, exploratory analysis and parametric approach) showed the same results, namely the existence of the aging effect only for the microtensile bond; in the comparison betw...
18

Efeito da aplicação de sistemas adesivos autocondicionantes associados ao laser Nd:YAG na prevenção do desgaste erosivo/abrasivo do esmalte dental

Crastechini, Érica [UNESP] 14 January 2014 (has links) (PDF)
Made available in DSpace on 2014-08-13T14:51:00Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-01-14Bitstream added on 2014-08-13T17:59:38Z : No. of bitstreams: 1 000776317.pdf: 1195102 bytes, checksum: 85fc35fb403e655b035d4a9783d36061 (MD5) / O objetivo deste estudo foi avaliar a eficácia do laser Nd:YAG associado a diferentes sistemas adesivos autocondicionantes, na prevenção do desgaste erosivo e abrasivo do esmalte dental. Foram preparados 160 espécimes de esmalte bovino, polidos e submetidos a uma erosão inicial em ácido cítrico a 0,3 % por 5 min. Os perfis iniciais da superfície de esmalte foram medidos utilizando um perfilômetro, cuja unidade de medida é em micrométros (μm). Os espécimes foram distribuídos aleatóriamente em oito grupos (n=20): SB - Aplicação do adesivo Single Bond Universal (3M/Espe) e fotopolimerização; SB+L - Aplicação do adesivo Single Bond Universal, irradiação do laser de Nd:YAG (80 mJ,10 Hz) e fotopolimerização; FB - Aplicação do adesivo Futura Bond U (Voco) e fotopolimerização; FB+ L - Aplicação do adesivo Futura Bond U, irradiação do laser de Nd:YAG e fotopolimerização; GEN - Aplicação do adesivo G-aenial Bond (GC) e fotopolimerização; GEN +L - Aplicação do adesivo G-aenial Bond, irradiação do laser de Nd:YAG e fotopolimerização; L - Apenas irradiação do laser Nd:YAG; C - nenhum tratamento (Controle). Em seguida foram realizados diariamente os desafios erosivo, utilizando ácido cítrico a 0,3% (pH 2,6) por 2 min, e abrasivo realizado em uma máquina de escovação (40 ciclos, carga 200 g) com dentifrício diluído em saliva artificial (1:3 peso/peso). Foram realizados quatro ciclos por dia, durante 5 dias. Os perfis das superfícies do esmalte foram novamente avaliados utilizando um perfilômetro. Os dados foram analisados utilizando o teste de análise de variância ANOVA e Tukey. O nível de significância foi de 5 %. Para a ANOVA foram observadas diferenças estatisticamente significantes (p= 0,0000) de desgaste. Os valores de média (±dp) e os resultados do teste Tukey foram: GEN – 4,88 (±1,09) a; L – 5,04 (±0,99) a; FB - 5,32 (±0,93) ab; GEN .... / The aim of this study was to evaluate the effectiveness of the Nd: YAG laser, alone or associated with different auto constraints adhesive systems, in the prevention of erosive and abrasive wear of the dental enamel. A hundred and sixty samples of bovine enamel were prepared, polished and subjected to an initial erosion in 0.3 % citric acid solution for 5 min. The initial profiles of the enamel surface were measured using a profilometer, whose unit is measured in micrometers (μm). The samples were randomly divided into eight groups (n = 20): SB - Single Bond Universal (3M/Espe) adhesive application and light curing; SB+L - Single Bond Universal adhesive application, Nd:YAG laser irradiation (80 mJ, 10 Hz) and light curing; FB - Futura Bond U (Voco) adhesive application and light curing; Group FB+L - Futura Bond U adhesive application, Nd:YAG laser irradiation and light curing; GEN - G-aenial Bond (GC) adhesive application and light curing; GEN+L - G-aenial Bond adhesive, Nd:YAG laser irradiation and light curing; L - Only Nd:YAG laser irradiation; C - No treatment (control group). The erosive challenge, using citric acid 0.3 % (pH 2.6) for 2 min, and abrasive challenge, using a tooth brushing machine (40 cycles, load of 200 g) with toothpaste diluted in artificial saliva (1:3 wt/wt), were performed. Four cycles a day were performed during 5 days. The profiles of the enamel surfaces were again measured using the profilometer. Data were analyzed using analysis of variance (ANOVA) and Tukey statistical tests. The level of significance was 5%. When ANOVA (one factor) test was applied, it was observed statistical difference (p=0,0000) of surface wear. Mean values (± SD) and results of the Tukey test were: GEN – 4,88 (±1,09) a; L – 5,04 (±0,99) a; FB - 5,32 (±0,93) ab; GEN + L – 5,46 (±1,27) abc; SB + L – 5,78 (±1,12) abc; FB + L – 6,23 (±1,25) bc; SB - 6,35 (±1,11) c; C .....
19

Comparação da infiltração marginal de restaurações adesivas empregando instrumento rotativo ou um sistema químico-mecânico na remoção do tecido cariado

Naressi, Suely Carvalho Mutti [UNESP] 16 August 1999 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:31Z (GMT). No. of bitstreams: 0 Previous issue date: 1999-08-16Bitstream added on 2015-01-26T13:30:17Z : No. of bitstreams: 1 000124606.pdf: 3794271 bytes, checksum: 0b7e3cd809f5ce39ab4e03000f54651a (MD5) / Considerando a validade da proposta de remoção químico-mecânica face às vantagens e indicações que o produto Carisolv apresenta e visando a realização de restaurações duradouras, esta pesquisa teve como objetivo comparar o selamento de restaurações adesivas após a remoção químico-mecânica da cárie com Carisolv (Medi Team) e com o método convencional empregando instrumentos rotatórios. Para tanto, foram utilizados sessenta dentes molares humanos cariados que após a remoção da cárie pelas duas técnicas, receberam restaurações com os materiais adesivos Vitremer (3m), Dyract (Dentsply DeTrey) e TPH Spectrum (Dentsply DeTrey). Foi empregada a metodologia para mícroinfiltração com o corante Rodamina B a 0,2% em todos os corpos de prova, que posteriormente foram seccionados em cortadeira especial e avaliados em estereomicroscópio óptico, atribuindo-se escores conforme o grau de microinfiltração observado. A análise estatística constou dos testes não paramétricos de Kruskaii-Wallis e Mann-Whitney cujos resultados evidenciaram que a infiltração marginal ocorreu na maioria das amostras avaliadas; que a diferença entre os escores apresentados pelos materiais não foi significante com a técnica convencional, porém foi significante quando o Carisolv foi empregado; que o Vitremer apresentou os mais altos valores de microinfiltração em ambas as técnicas e que a remoção do tecido cariado pelo método convencional ou químico-mecânico com Carisolv, não influenciou o desempenho selador dos materiais adesivos empregados / The chemo-mechanical removal of carious tissue using Carisolv (MediTeam) presents several advantages and indications, when lasting adhesive fillings are expected. This research proposes to compare the sealing conditions of adhesive restorations placed on teeth submitted either to the chemo-mechanical method using Carisolv or to the traditional bur method of caries removal. Sixty decayed human molars received, after the removal of the carious tissue, adhesive fillings of Vitremer (3M), Dyract (Dentsply DeTrey) e TPH Spectrum (Dentsply DeTrey). The microleakage was observed using the 0,2% Rodamine B dye method in all the samples. The samples were sectioned and examined under optical stereomicroscopy. The statistical analysis using the Kruskall-Wallis and Mann-Whitney non-parametrics tests showed the existence of marginal leakage in most samples; the differences observed in the materials tested were not significant when the traditional method was used but a statistically significant difference existed when Carisolv was employed; the highest levels of microinfiltration occured with Vitremer and the sealing properties of the various adhesive materials were not influenced by the caries removal method applied
20

Avaliação da microinfiltração marginal em restaurações de resina composta, quando o colágeno dentinário é mantido ou eliminado após o condicionamento ácido, alterando-se o período de armazenamento e a termociclagem

Torres, Carlos Rocha Gomes [UNESP] 15 March 2002 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:31Z (GMT). No. of bitstreams: 0 Previous issue date: 2002-03-15Bitstream added on 2015-01-26T13:30:16Z : No. of bitstreams: 1 000148105.pdf: 6603398 bytes, checksum: b573466a374fbc1a46aedaa48a08fe0f (MD5) / O objetivo deste estudo foi avaliar o grau de microinfiltração marginal em restaurações de resina composta, diante das variáveis remoção ou não do colágeno dentinário após o condicionamento ácido, e utilização ou não de uma camada de resina composta fluida sobre a dentina desproteinizada, alterando-se os seguintes fatores: a)tempo de armazenagem (0, 6 e 12 meses): b) ciclagem térmica (500, 1.500 e 2.500 ciclos). Para tal, 180 dentes bovinos receberam preparos classe V ao nível da junção amelocementária. Eles foram divididos em três grupos: grupo C - foi aplicado o sistema adesivo Single Bond (3M), segundo as recomendações do fabricante, e a seguir procedida a restauração com a resina composta Z250 (3M); grupo H - após o condicionamento ácido foi aplicada uma solução aquosa de NaOCI a 10% por 1 min, e então aplicado o adesivo Single Bond e a resina composta Z250; grupo HF- semelhante ao grupo H, exceto que após a polimerização do adesivo, uma fina camada de resina composta fluída Natural Flow (DFL) foi aplicada e polimerizada, antes da inserção da resina Z250. Todos os espécimes sofreram 500 ciclos ténnicos (5 ±5°C a 55 ±5°C). Os espécimes em cada grupo foram divididos ao acaso em três subgrupos. No primeiro, a microinfiltração marginal foi avaliada após 24h. No segundo, os espécimes permaneceram imersos em água destilada contendo 0,4% de azida sódica em estufa a 37°C por seis meses, sendo que após este período sofreram mais 1.000 ciclos térmicos. No terceiro, os espécimes permaneceram imersos por 12 meses, e receberam mais 1.000 ciclos térmicos a cada 6 meses, totalizando 2.500 ciclos. Após os respectivos períodos de armazenagem, a microinfiltração marginal foi avaliada pelo método do nitrato de prata seguido pela diafanização. Os espécimes foram analisados em estereomicroscópio e receberam escores de 0 a 4. Os dados... / The aim of this study was to evaluate the marginal microleakage in composite resin restorations. under the variables removal or not of the dentin collagen after the acid conditioning, and utilization or not of a flowable composite resin layer on deproteinized dentin, changing the factors: a) storage time (0, 6 and 12 months); b) thermal cycling (500, 1.500 and 2.500 cycles). For this, 180 bovine teeth received class V cavit preparation at cementun-enamel junction. They were assigned to three groups: group C - was applied the Single Bond adhesive system (3M), according to manufacturer instructions, and restored with Z250 composite resin (3M); group H - after the acid conditioning was applied a 10% NaOCI aqueous solution for 1min, and then applied the adhesive and restored with Z250; group HF - like the group H, except that after the adhesive polymerization. a thin layer of a flowable composite resin Natural Flow (DFL) was applied and polimerized, before the placement of Z250. AIl specimens received 500 thermal cycles (5±5'C to 55±5-'C). The specimens in each group were randomly assigned to three subgroups. In the first, the microleakage was evaluated after 24h. In second, the specimens were stored in distillate water containing 0,4% of sodium azide in stove at 37'C, for 6 months, and after this time received more 1.000 thermal cycles. In the third, the specimens were stored for 12 months, and they received more 1.000 thermal cycles for each 6 months. At the end of each storage time, the microleakage was evaluated by the silver nitrate method, followed by cleaning technique. The specimens were analyzed in stereomicroscope and received scores of 0 to 4. The data were submitted to statistical analysis, using the Kruskal Wallis's and Multiple Comparisons tests. After 6 months of storage, the groups H and HF showed falls in microleakage, while the group C didn't showed significant differences

Page generated in 0.0846 seconds