• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 74
  • Tagged with
  • 74
  • 74
  • 34
  • 30
  • 26
  • 21
  • 16
  • 16
  • 14
  • 14
  • 11
  • 9
  • 9
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Resistência ao microcisalhamento de diferentes sistemas adesivos no esmalte dental humano

Nagayassu, Marcos Paulo [UNESP] 27 June 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:25Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-06-27Bitstream added on 2014-06-13T21:02:25Z : No. of bitstreams: 1 nagayassu_mp_dr_sjc.pdf: 569285 bytes, checksum: 26edda3951c5eb0e27050fe830c365f3 (MD5) / O objetivo deste estudo foi avaliar in vitro a resistência ao microcisalhamento de 5 sistemas adesivos ao esmalte, sendo 1 adesivo monocomponente (M), 2 primers autocondicionantes (P) e 2 adesivos autocondicionantes (A). Foram utilizadas 60 faces (vestibular ou lingual) de pré-molares, aplainadas com lixas d'água (400 e 600) e divididas aleatoriamente em 5 grupos (n=12), de acordo com o adesivo utilizado: SB2- Single Bond2 (M); CSE- Clearfil SE Bond (P); ADS- AdheSE (P); PLP- Adper Prompt L-Pop (A); XE3- Xeno III (A). Tubos de Tygon delimitaram a área de adesão em 0,8mm de diâmetro, para se obter os cilindros de resina composta (Z250). Após armazenamento em água destilada a 37ºC por 24h e termociclagem, foi realizado o teste de microcisalhamento (velocidade de 0,5mm/min).). Os dados foram submetidos aos testes de ANOVA e Tukey ('alfa'=5%). Os valores de média (MPa'mais ou menos'DP) e os resultados do teste de Tukey foram: SB2: 36,36('mais ou menos'3,34)a; ADS: 33,03('mais ou menos'7,83)a; XE3: 32,76('mais ou menos'5,61)a; CSE: 30,61('mais ou menos'6,68)a; PLP: 22,17('mais ou menos'6,05)b. Grupos com a mesma letra não apresentaram diferenças significantes. Pode-se concluir que não houve diferença estatística entre SB2, ADS, XE3 e CSE, apesar dos diferentes padrões de condicionamento destes adesivos. Apenas o PLP apresentou valores médios de adesão inferiores aos demais. / The aim of this in vitro study was to evaluate the micro-shear bond strength of 5 adhesive systems to enamel, one single-bottle acid-etch adhesive (O), two selfetching primers (P) and two all-in-one self-etching adhesives (S). Sixty premolar enamel surfaces (buccal or lingual) were ground flat with 400- and 600-grit SiC papers and randomly divided into 5 groups (n=12), according to adhesive system: SB2 - Single Bond 2 (O); CSE - Clearfil SE Bond (P); ADS - AdheSE (P); PLP - Adper Prompt L-Pop (S); XE3 - Xeno III (S). Tygon tubing (internal diameter of 0,8mm) restricted the bonding area to obtain the resin composite (Z250) cylinders. After storage in distilled water at 37oC for 24h and thermocycling, micro-shear testing was performed (crosshead speed of 0.5mm/min). Data were submitted to one-way ANOVA and Tukey test ('alfa'=5%). Mean bond strength values (MPa'mais ou menos'SD) and the results of Tukey test were: SB2: 36.36('mais ou menos'3.34)a; ADS: 33.03('mais ou menos'7.83)a; XE3: 32.76('mais ou menos'5.61)a; CSE: 30.61('mais ou menos'6.68)a; PLP: 22.17('mais ou menos'6.05)b. Groups with the same letter were not statistically different. It can be concluded that no significant difference was there between SB2, ADS, XE3 and CSE, in spite of different etching patterns of these adhesives. Only PLP presented statistically lower bond strengths compared with others.
62

Análise da resistência adesiva à dentina de diferentes sistemas adesivos pelo teste de microtração e microscopia eletrônica de varredura

Mazur, Rui Fernando [UNESP] 10 November 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:27Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-11-10Bitstream added on 2014-06-13T20:41:47Z : No. of bitstreams: 1 mazur_rf_dr_arafo.pdf: 2691655 bytes, checksum: aa6766566238765dc0a1f4d5cb633eda (MD5) / O objetivo deste trabalho foi realizar, in vitro, avaliação da resistência de adesiva pelo teste de microtração de dez sistemas adesivos diferentes. Os sistemas adesivos One Up Bond F - Tokuyama, Clearfil SE Bond - Kuraray, Adper Prompt L-Pop, Single Bond - 3M/ESPE, One Step - Bisco, One Step Plus - Bisco, Prime&Bond NT - Dentsply, Excite - Vivadent, Scotchbond Multi - Uso - 3M/ESPE e All Bond 2 - Bisco. Para a realização do teste foram utilizados quarenta dentes molares hígidos, sendo que destes dentes dez foram utilizados para a microscopia eletrônica de varredura. Para a realização do teste de microtração os dentes foram cortados na superfície oclusal com disco diamantado e posteriormente foram desgastados com discos de lixa. Posteriormente as amostras foram restauradas com os respectivos sistemas adesivos e resina composta Z-100 com tempo de polimerização de 40 segundos cada incremento. Após vinte e quatro horas de armazenagem em temperatura de 37ºC os dentes foram seccionados com disco diamantado com finalidade de obter palitos com área de 1,0 +- 0,2 mm2. Após o corte os palitos foram armazenados em temperatura de 37ºC por vinte e quatro horas e em seguida foram levados para a máquina de ensaio universal EMIC 500 DL onde os palitos foram tracionados com velocidade de 1 mm/min. Os resultados foram analisados pelo através dos testes de normalidade de Lilliefors e de homogeneidade de variância de Bartlett. Quando alguns dos pressupostos não se verificaram, utilizou-se o teste não paramétrico de Kruskal - Wallis. Os resultados obtidos foram em ordem decrescente de 36,73 +- 10,52 para o sistema adesivo One Up Bond F, seguido do sistema de três etapas All Bond 2 com 34,29 +- 12,63 para o sistema adesivo One Step Plus foi de 33,18 +- 11,33 para o sistema Adper Prompt L-Pop de 31,76 +- 11,3, sistema One Step de 29,02 +- 11,28, para o... . / The aim of this study was to analyze the bond strength of ten adhesive systems: One Up Bond F - Tokuyama (OU); Adper Prompt L-Pop - 3M-ESPE (AP); Clearfil SE Bond - Kuraray CO. (SE); Prime Bond NT - Caulk-Dentsply (NT); Single Bond - 3M-ESPE (SB); One Step - Bisco (OS); One Step Plus - Bisco (OP); Excite - Vivadent (EX); Scotchbond Multi - Purpose (SMP) e All Bond 2 - Bisco (AB). Methods: Forty freshly extracted human teeth were transversely wetcut using a diamond disk in order to expose the occlusal dentin surface. Then the adhesive systems were applied according to the manufacturer's instruction. The teeth were restored with composite resin Z-100 (3M) and stored in distilled water at 37ºC for 24 hours. A slow-speed diamond disk was used to prepare microtensile test specimens, with a bonded area of 1,00 +- 0,2 mm2. Each group was composed of thirty sticks, which were stored in distilled water at 37ºC for 24 hours. The sticks were bonded on a universal testing machine at a cross head speed of 1 mm/min. The following results demonstrate values microtensile bond strengths in MPa. Data were statistically analyzed by Kruskal-Wallis Test (p<-0.05). The bond strength values were 36,73 +- 10,52 for One Up Bond F, 34,29 +- 12,63 for All Bond 2, 33,18 +- 11,33 for One Step Plus, 31,76 +- 11,3 for Adper Prompt L-Pop, 29,02 +- 11,28 for One Step, 28,82 +- 14,74 for Single Bond, 28,08 +- 12,09 for Clearfil SE Bond, 26,31 +- 9,02 for Scotchbond Multi - Purpose, 21,35 +- 10,22 for Prime&Bond NT and 19,52 +- 10,08 for Excite. Ten teeth were analysed by SEM and all of them showed resin into the dentin tubules. Most of fractures were adhesive in the composite/teeth interface. One up bond F (OU) resulted in higher bond strength when compared to all the other systems tested and Excite resulted in lower bond strength. Self-etching systems were not statistically... (Complete abstract, click electronic address below).
63

Avaliação da resistência de união à tração e espessura de camada híbrida : influência de sistemas adesivos e condições de substrato dentinário

Susin, Alexandre Henrique [UNESP] 08 October 2002 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:27Z (GMT). No. of bitstreams: 0 Previous issue date: 2002-10-08Bitstream added on 2014-06-13T19:01:43Z : No. of bitstreams: 1 susin_ah_dr_arafo.pdf: 3155550 bytes, checksum: 3c18f1511d8950d04d4fb3ead12080d0 (MD5) / O objetivo deste trabalho foi realizar, in vitro, avaliação da resistência de união à tração (RUT) e espessura de camada híbrida (ECH), em diferentes condições de substrato dentinário (úmido, S1; desidratado, S2 e reumedecido, S3), proporcionado pelos sistemas adesivos de 4ª geração, Scotchbond Multi Uso (SBMU) - 3M ESPE; Single Bond (SB) - 3M ESPE; Prime & Bond 2.1 (P&B2.1) - Dentsply e One Coat Bond (OCB) - Coltène-Whaledent, e os sistemas adesivos de 5ª geração (autocondicionantes), Clearfil SE Bond (CSEB) - Kuraray e One Up Bond F (OUBF) - Tokuyama. Foram utilizados 180 dentes seccionados na altura do 1/3 médio da coroa, originando duas partes cada um: remanescente dental (utilizado no teste de resistência de união à tração) e fragmento oclusal (utilizado na mensuração de camada híbrida). Para cada um dos 18 grupos foram realizadas 10 repetições em cada um dos dois testes, perfazendo um total de 360 amostras. O teste de RUT, foi realizado na Máquina de Ensaios Mecânicos MTS-810, em velocidade de 2 mm / min., e a ECH, foi mensurada à partir de fotografias obtidas em microscopia eletrônica de varredura (Microscópio Eletrônico JSM 330 A), com o software Image Tool 2.00. No teste de RUT, o desempenho dos sistemas adesivos foi melhor em S1 e, dentre eles, o CSEB foi o que apresentou a maior média, 23,01 MPa, enquanto que a menor, foi apresentada pelo OUBF, 15,69 MPa. Os sistemas adesivos de 4ª geração apresentaram médias intermediárias, às quais não foi possível encontrar diferenças estatisticamente significantes. (SBMU, 18,71 MPa; SB, 19,43 MPa; P&B2.1, 17,45 MPa e OCB, 19,92 MPa). As menores médias de RUT dos sistemas adesivos de 4ª geração, foram constatadas em S2, apresentando a menor média para o SB, 6,64 MPa, enquanto que os sistemas autocondicionantes, apresentaram menores variações de RUT entre os... . / The aim of this work was to perform the evaluation of the tensile bond strength (TBS) and the thickness of the hybrid layer (THL), in different conditions of dentinal substrate (moist, S1; dehydrated, S2 and remoistened, S3), provided by the fourth generation adhesive systems, Scotchbond Multi Uso (SBMU) - 3M ESPE; Single Bond (SB) - 3M ESPE; Prime & Bond 2.1 (P&B2.1) - Dentsply and One Coat Bond (OCB) - Coltène-Whaledent, and the fifth generation adhesive systems (self-etching), Clearfil SE Bond (CSEB) - Kuraray and One Up Bond F - Tokuyama. One hundred and eighty teeth bisected in the 1/3 crown mean level were used, originating two parts each: dental remnant (used in the tensile bond strength testing) and occlusal fragment (used in the hybrid layer measurement). For each of the 18 groups, 10 repetitions were performed for both tests, in a total of 360 samples. The TBS test was performed in a Mechanic Testing Machine MTS-810, in speed 2 mm/ min, and the THL was measured from photographs obtained in scanning electron microscopy (Electron Microscope JSM 330 A), using a software Image Tool 2.00. During the TBS test, the performance of the adhesive systems was better in S1 and, among themselves, CSEB presented the higher average, 23,01 MPa, while the lower average was presented by OUBF, 15,69 MPa. The fourth generation adhesive systems presented intermediate averages, those which did not revealed statistically significant differences. (SBMU, 18,71 MPa; SB, 19,43 MPa; P&B2,1, 17,45 MPa and OCB, 19,92 MPa). The lower averages of the fourth generation adhesive systems in TBS were verified in S2, presenting the lower average for SB, 6,64 MPa, while the self-etching systems presented lower TBS variations among the different substrates. In the THL results, lower variability was verified among the average results obtained, being the higher average presented by SBMU, 4,80 æm... (Complete abstract, click electronic address below).
64

Estudo comparativo da eficacia de dois adesivos dentinarios e um cimento de ionomero de vidro empregados na adesão do amalgama a dentina

Huhtala, Maria Filomena Rocha Lima [UNESP] 30 May 1995 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:25Z (GMT). No. of bitstreams: 0 Previous issue date: 1995-05-30Bitstream added on 2015-01-26T13:30:31Z : No. of bitstreams: 1 000024290.pdf: 5225535 bytes, checksum: 2f40e06083b5452b27fb8895454432ad (MD5) / Este estudo teve como objetivo realizar a avaliação ln vitro, da resistência da adesão do amálgama, Dispersalloy, à dentina, quando dois adesivos dentinários, Amalgambond Plus (AP) e Scotchbond Multi Purpose (SMP) e um cimento de ionômero de vidro, Vitrebond (V), foram empregados no tratamento desta superfície dentinária. Trinta dentes terceiros molares humanos recém-extraídos, foram seccionados em metades vestibular e lingual, que foram incluídas em blocos de resina acrílica, de modo a terem suas superfícies dentinárias superficiais expostas com lixas de granulação crescente: 100, 180, 400 e 600; sob constante refrigeração de água. Sobre estas superfícies dentinárias foram fixados tubos de polietileno com 3 mm de diâmetro e 5 mm de altura, estabilizados com uma matriz de teflon e alumínio, permitindo assim a condensação do amálgama, imediatamente após o tratamento com um dos sistemas adesivos: AP, SMP,V. Após a confecção dos cilindros de amálgama, as amostras foram estocadas à 37º C por 24 horas, antes de serem submetidas aos testes mecânicos de cisalhamento em máquina Instron a uma velocidade de 0,5 mm/minuto. Os resultados da força requerida para o cisalhamento dos cilindros de amálgama foram expressos em MPa e as superfícies, dentinárias e de amálgama, observadas em estereomicroscopia, após a fratura. Os dados foram analisados através do modelo estatístico de análise de variância. A força média de adesão, quando como agente intermediário entre amálgama/ dentina, foi utilizado o AP, foi de 2,21 ± l ,5 MPa , quando o SMP de 0,33 ± 0,8 MPa e o V de 2,63 ± 1,66 MPa. O AP e o V foram considerados estatisticamente semelhantes (p>0,05) e diferentes do SMP (p<0,05). As fraturas foram predominantemente adesivas na interface amálgama/resina para o SMP (73,34%) e consideradas mistas, do amálgama/sistema adesivo, para o AP (80%) e para o V (93,36%) / The purpose of this in vitro study was to determine the shear bond strengths of amalgam to dentin treated with the Amalgambond Plus (AP) and Scotchbond Multi Purpose (SMP) dentin adhesive systems and with the glass-ionomer cement, Vitrebond (V).The buccal and lingual superficial dentin surfaces of thirty extracted human third molars were exposed by wet grinding on 600-grit silicon carbide and the bonding areas demarcated with plastic band matrices (3mm/5umm),fixed in position by the means of a rigid aluminium/teflon mold. The demarcated dentin surfaces were treated with AP, SMP and V as directed by the manufacturers and freshly mixed Dispersalloy amalgam condensed into the plastic matrices. The specimens were then stored in 37°C for 24 hours. The matrices were removed; the shear bond tests performed in an Instron Universal Testing Machine at a cross-head speed of 0.5mm/sec.; and the results expressed in MPa. Some failures were examined in stereomicroscopy. The data were analysed by one-way analysis of variance, Mean failure loads and S.D, were: AP, 2,21 ± 1,5; SMP, 0,33±0,8 e V, 2,63± l,6. Tire shear bond strengths of AP vs V were not significantly different (p>0,05) and SMP was significantly different (p<0,05), Stereomicroscopic analysis demonstrated adhesive failures for SMP (7334%) at the resin/amalgam interface and mixed failures for AP (80%) and for V (933%) within both systems
65

Estudo comparativo in vitro da resistência ao cisalhamento de discos metálicos de níquel-cromo, com ou sem tratamento de superfície, unidos à dentina bovina com quatro cimentos

Uemura, Eduardo Shigueyuki [UNESP] 21 June 1999 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:31Z (GMT). No. of bitstreams: 0 Previous issue date: 1999-06-21Bitstream added on 2015-01-26T13:30:17Z : No. of bitstreams: 1 000127814.pdf: 3655431 bytes, checksum: 12e1609540144e91b6188d471f4f987c (MD5) / O estudo foi realizado com oitenta incisivos inferiores bovinos. Os dentes foram extraídos, limpos, as raízes foram seccionadas, o tecido pulpar coronário foi removido e submetido à congelamento a -18°C, por um tempo máximo de 28 dias. A inclusão foi feita em gesso pedra tipo IV. Após o desgaste do esmalte, a dentina superficial foi preparada numa área de 5mm, sendo que a espessura de dentina remanescente foi padronizada (1 ,7 a 2mm). Os discos de liga de Ni-Cr tinham 3X5mm de diâmetro e todos foram submetidos a um ciclo de queima de cerâmica. Metade dos discos foram jateados com óxido de alumínio de 50µm.enquanto a outra metade não sofreu este tratamento. Após limpeza em ultra•som os discos foram cimentados à dentina com: cimento de fosfato de zinco-S.S.White (controle), cimento de ionômero de vidro modificado por resina (CIVMR) Fuji Plus-Fuji, Cimento Resinoso 3M-3M e cimento resinoso Panavia 21-Kuraray. Os dados, após análise estatística ANOVA e teste de Tukey (p< 0,05), mostraram para as variáveis cimento e tratamento de superfície dos discos metálicos os seguintes valores médios de resistência da união dentina/cimento/metal: cimento resinoso Panavia 21 com jateamento (18,29MPa), sem jateamento (17,87MPa); Cimento Resinoso 3M com jateamento (15,81MPa), sem jateamento (11,40MPa); CIVMR com jateamento (16,57MPa), sem jateamento (16,70MPa); cimento de fosfato de zinco com jateamento (3,35MPa), sem jateamento (0,9BMPa). As médias dos valores de resistências ao cisalhamento permitiram concluir: a) houve diferença estatisticamente significante entre o cimento controle e os cimentos em teste; b) não houve diferença estatisticamente significante entre o cimento resinoso Panavia 21 e o CIVMR, mas ambos foram estatisticamente diferentes do cimento resinoso 3M; c) houve diferença estatisticamente significante entre as médias de resistência dos espécimes jateados / This study was carried out with 80 bovine lower incisors. After extraction and debridement the teeth were cut in two parts (crown and roof), having the pulp tissue removed. Crowns were frozen at -18° C for a maximum period of 28 days and then embedded in type IV stone. Preparations were carried out in superficial dentin (minimum 5mm area) while the remaining dentin thickness was standardized (1.7 to 2mm). 80 Ni-Cr disks (3mm height, 5mm diameter) were submitted to a ceramic firing cycle. Half the disks had a 50µm AL2O3 blast while the other half did not. Cements used were: ZPC -SSW, GICRM Fuji Plus-Fuji; 3M resinous cement - 3M; resinous cement Panavia 21- Kuraray. After ANO VA statistical analysis and Tukey's test (p> 0.05), data showed the following shear bond strength mean values at the interface dentin/cement/Ni-Cr disks: dentin/Panavia 21/ blasted Ni-Cr disks (18,29MPa), dentin/Panavia 21/ non blasted Ni-Cr disks (17, 87MPa); dentin/Fuji Plus/blasted Ni-Cr disks (16,57MPa), dentin/Fuji Plus/non-blasted Ni-Cr disks (16.70MPa); dentin/3M resinous cement/blasted Ni-Cr disks (15.81 MPa), dentin/3M resinous cement/non-blasted Ni-Cr disks (11,40MPa); dentin/ZPC/blasted Ni-Cr disks (3,35 MPa), dentin/ZPC/non-blasted Ni-Cr disks (O,98MPa). Results lead to the conclusions: a) control and tested cements mean shear bond strength values showed a significant statistical difference; b) there was no significant statistical difference between Fuji Plus and Panavia mean shear bond strengths, though both values differed statistically from 3M resinous cement mean shear bond strength; c) blasted and non-blasted specimens mean shear bond strength values showed a statistical significant difference; d) There was no significant statistical difference between resin modified GICRM and Panavia 21 mean shear bond strength values, with or without Ni-Cr disks blasting
66

Efeito de diferentes soluções irrigadoras na resistência de união dentina radicular - adesivo autocondicionante

Martins, Giovana Ribeiro de [UNESP] 26 June 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:46Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-06-26Bitstream added on 2014-06-13T20:36:13Z : No. of bitstreams: 1 martins_gr_me_sjc.pdf: 3223444 bytes, checksum: 86988c1a5d4c8b8f82b29a6fd9eef209 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A restauração de dentes tratados endodonticamente continua a ser fator chave para o sucesso do tratamento. O objetivo deste estudo foi avaliar a resistência de união entre um sistema adesivo autocondicionante/cimento resinoso e a dentina intra-radicular dos terços cervical e médio, em função de diferentes protocolos de irrigação. Sessenta dentes humanos unirradiculados receberam tratamento endodôntico e foram divididos em três grupos (n = 20) de acordo com a solução irrigadora durante o preparo biomecânico: GRUPO 1 (controle): soro fisiológico; GRUPO 2: hipoclorito de sódio (NaOCl) 2,5%; e GRUPO 3: clorexidina gel (CLX) 2%. Após obturação endodôntica, os dentes foram preparados e pinos de cimento resinoso cimentados depois de diferentes tratamentos da dentina radicular do espaço para pino, de acordo com os grupos anteriores, porém subdivididos em A e B (n =10) acrescentando ou não o EDTA 17%: G1A: soro fisiológico; G1B: soro fisiológico + EDTA 17%; G2A: NaOCl 2,5%; G2B: NaOCl 2,5% + EDTA 17%; G3A: CLX gel 2%; G3B: CLX gel 2% + EDTA 17%. Todos os espécimes foram seccionados em 4 fatias (2 cervicais e 2 médias) para ensaio mecânico de extrusão por cisalhamento (push-out). Os padrões de fratura foram analisados em lupa e os dados numéricos obtidos após ensaio mecânico foram analisados estatisticamente pelo teste ANOVA. Uma amostra de cada grupo foi confeccionada para observação da interface dentina/resina em MEV. As médias (MPa), em ordem decrescente, foram: grupo 2A) 5,95; grupo 3A) 5,72; grupo 3B) 4,77; grupo 2B) 4,26; grupo 1A) 4,22; grupo 1B) 3,60. Os grupos tratados com NaOCl 2,5% e CLX gel 2% obtiveram melhores resultados do que o controle e o EDTA diminuiu a resistência de união em todos os grupos, porém sem diferenças estatisticamente significantes (P > 0,05). As médias de acordo com as regiões do canal foram:... / Besides the sucess of root canal treatment of teeth, a successful final restoration is also important for long-term clinical sucess. The influence of endodontic irrigation on bond strengths of resin cement (self-etching adhesive) to radicular dentin was investigated. Sixty extracted single-rooted human teeth were subjected to post space preparation after endodontic therapy with three different root canal irrigants (n = 20): Group 1: 0,9% sodium chloride (control); group 2: 2,5% sodium hypochlorite (NaOCl); group 3: 2% chlorhexidine gel (CHX). Post space was also treated with sodium chloride, NaOCl or CHX and subdivided into A and B (without or with 17% EDTA) (n = 10). Posts of resin cement were cemented and the specimes were sectioned into four dental slices approximately 2 mm each (2 cervical, 2 middle). They were submitted to the push-out test. The data were submitted to an analysis of variance (ANOVA) and scanning electron microscopic (SEM) analysis was performed in specimes. The mean values (MPa) obtained were: Group 2A) 5,95 > Group 3A) 5,72 > Group 3B) 4,77 > Group 2B) 4,26 > Group 1A) 4,22 > Group 1B) 3,60. The groups that used 2,5% NaOCl and 2% CHX showed highest retention, and 17% EDTA decreased bond strength to root canal dentin, however, no significant differences were found among groups (p > 0,05)...(Complete abstract click electronic access below)
67

Resposta pulpar de dentes de ratos após tratamento capeador direto com sistema adesivo monocomponente ou autocondicionante

Favaretto, Lúcia Helena Denardi Roveroni [UNESP] 14 July 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:04Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-07-14Bitstream added on 2014-06-13T19:08:51Z : No. of bitstreams: 1 favaretto_lhdr_me_sjc.pdf: 917162 bytes, checksum: e8cc872310ab876c14fe70a8cf5a5d20 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo do trabalho foi avaliar a resposta pulpar de dentes de ratos a diferentes sistemas adesivos diretamente aplicados sobre exposições pulpares. Foram realizados preparos oclusais com exposição pulpar nos primeiros e segundos molares superiores. O grupo C (controle, n=34) recebeu como material capeador o cimento de hidróxido de cálcio Dycal, no E1 (n=31) foi aplicado o sistema adesivo Single Bond e no E2 (n=30) o sistema adesivo auto-condicionante One-up Bond F. Os materiais foram aplicados conforme especificações dos fabricantes e todas as cavidades restauradas com resina composta. Os animais foram sacrificados após sete, trinta e 45 dias e as polpas dentárias foram histologicamente avaliadas. Os dados foram analisados estatisticamente utilizando-se o teste exato de Fisher. Observou-se que aos sete dias não houve diferença entre C e E2 com relação à resposta inflamatória e à organização pulpar, predominando quadros de inflamação crônica focal e perdas odontoblásticas localizadas. O E1 demonstrou diferença estatisticamente significativa em relação ao E2, exibindo maior número de casos com necrose. Aos sete dias a contaminação bacteriana da polpa foi menor no grupo tratado com One-up, porém, todas as diferenças mencionadas foram perdidas com o decorrer do tempo, equiparando-se os três grupos aos 45 dias, período em que predominou a necrose pulpar. Houve um aumento no número de barreiras dentinárias formadas e na contaminação bacteriana do tecido pulpar com o aumento do tempo experimental. Concluiu-se que o tratamento capeador direto, conforme o modelo experimental empregado, demonstrou ser histologicamente insatisfatório, independentemente do material empregado. / The aim of this study was to evaluate the pupal response to different adhesives systems directly applied on mechanically exposed pulps in rats. The oclusal surfaces of first and second molars were prepared and the pulps exposed. In C (control group-n=34) pulps were capped with a calcium hydroxide paste (Dycal); E1 (n=31) received the Single Bond adhesive system and E2 (n=30) was treated with the self-etching One-up Bond F adhesive system. The materials were applied according to the manufacture's instructions and cavities were restored with Z100 composite resin. Animals were sacrificed after seven, thirty and 45 days and histological features of the dental pulp were evaluated. The Fisher test was used as statistical analysis. At seven days C and E2 presented similar inflammatory response and pulpal organization, showing focal chronic inflammation and localized odontoblast cell lost. E1 and E2 demonstrated statistically significant difference regarding to pulpal organization and inflammatory response; the former exhibiting much more necrosis. At seven days, bacterial contamination of the dental pulp was less evident with One-up Bond F. All these differences were lost with time and after 45 days, pulpal necrosis and bacterial contamination prevailed in the three groups. The formation of the dentin barrier was greater with time in the three groups. The results presented suggest negative effects of direct pulp capping on molar teeth of rats using Dycal, One-up Bond F and Single Bond, under the experimental conditions described.
68

Resistência adesiva de sistemas autocondicionante e convencional frente a diferentes substratos e associação ao laser Nd:YAG: estudo in vitro

Marimoto, Ângela Regina Kimie [UNESP] 26 July 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-07-26Bitstream added on 2014-06-13T20:51:29Z : No. of bitstreams: 1 marimoto_ark_me_sjc.pdf: 390443 bytes, checksum: d76f9139d735bc954e3a1f9a3c6ec8ce (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A adesão continua a ser um desafio na Odontologia, principalmente em tecidos morfologicamente distintos e valendo-se de sistemas adesivos de mecanismos de ação também distintos. O objetivo deste estudo in vitro foi comparar a resistência adesiva de dois sistemas (autocondicionante e convencional) em dois substratos (esmalte e dentina), associados ou não à tecnologia laser (Nd:YAG). Foram utilizados 120 dentes bovinos, recém-extraídos, embutidos, que tiveram a superfície de esmalte ou dentina exposta por meio de lixas. Uma área de 3mm de diâmetro na região cérvico-vestibular-mediana foi selecionada para adesão, de acordo com os seguintes grupos: a) G1: AF/ esmalte (adesivo autocondicionante em esmalte seguindo especificação do fabricante); b) G2: AF/ dentina (adesivo autocondicionante em dentina seguindo especificação do fabricante); c) G3: AL/ esmalte (adesivo autocondicionante em esmalte + laser Nd:YAG + fotopolimerização); d) G4: AL/ dentina (adesivo autocondicionante em dentina + laser Nd:YAG + fotopolimerização); e) G5: CF/ esmalte (condicionamento ácido + adesivo convencional em esmalte); f) G6: CF/ dentina (condicionamento ácido + adesivo convencional em dentina); g) G7: CL/ esmalte (condicionamento ácido + adesivo convencional em esmalte + laser Nd:YAG + fotopolimerização); h) G8: CL/ dentina (condicionamento ácido + adesivo convencional em dentina + laser Nd:YAG + fotopolimerização). A resina composta Z 250 foi inserida com auxílio de matriz de teflon e fotopolimerizada com luz halógena, seguida da realização do teste de cisalhamento em máquina universal Emic, com carga de100kgf e velocidade de 0,5mm/min. Os valores médios em MPa obtidos para os diferentes grupos foram: G1 (20,291), G2 (14,142), G3 (23,615), G4 (22,235), G5 (20,899), G6 (11,291), G7 (22,102), G8 (15,980). Após aplicação do teste de ANOVA e Tukey 5%, concluiu-se que... / Bonding continues to be a challenge in Dentistry, particularly in morphologically different tissues, and adhesive systems with different action mechanisms are also valid. The aim of this study was to compare the bond strength of two systems (self-etching and conventional) to two substrates (enamel and dentin) either associated with laser technology (Nd:YAG) or not. One hundred and twenty (120) recently extracted, embedded bovine teeth were used, and abrasive papers were used to expose the enamel or dentin surfaces. An area of 3mm in diameter in the cervical-vestibular-median region was selected for bonding, according to the following groups: a) G1: AF/ enamel (self-etching adhesive to enamel in accordance with the manufacturer's specification); b) G2: AF/ dentin (self-etching adhesive to dentin in accordance with the manufacturer's specification); c) G3: AF/ enamel (self-etching adhesive to enamel + laser Nd:YAG + light polymerization ; d) G4: AL/ dentin (self-etching adhesive to dentin + laser Nd:YAG + light polymerization ; e) G5: CF/ enamel (acid etching + conventional adhesive to enamel); f) G6: CF/ dentin (acid etching + conventional adhesive to dentin); g) G7: CL/ enamel (acid etching + conventional adhesive to enamel + laser Nd:YAG + light polymerization ; h) G8: CL/ dentin (acid etching + conventional adhesive to dentin + laser Nd:YAG + light polymerization). Resin composite Z250 was inserted with the aid of a Teflon matrix and light polymerized, followed by the shear test in an EMIC universal machine, with a load of 100 Kgf and speed of 0.5 mm/min. The mean values obtained in Mpa for the different groups were: G1 (20.291), G2 (14.142), G3 (23.615), G4 (22.235), G5 (20.899), G6 (11.291), G7 (22.102), G8 (15.980). After applying the ANOVA and Tukey tests 5%, it was concluded that the application of laser Nd:YAG significantly increased the bond strength under all the experimental... (Complete abstract click electronic access below)
69

Avaliação da resistência de união de diferentes sistemas adesivos à dentina bovina: influência de agentes dessensibilizantes

Lima, Darlon Martins [UNESP] 23 February 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-02-23Bitstream added on 2014-06-13T19:51:24Z : No. of bitstreams: 1 lima_dm_me_arafo.pdf: 826526 bytes, checksum: ff1d690d6b0676f46d0b484cb8adef94 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste trabalho foi o de avaliar comparativamente in vitro, a resistência de união ao cisalhamento de uma resina composta à dentina bovina em função da combinação de três diferentes sistemas adesivos e de dois diferentes agentes dessensibilizantes. Foram utilizados os sistemas adesivos: Single Bond, Master Bond e Prime & Bond 2.1 e os seguintes agentes dessensibilizantes: o Oxagel e o G. H. F. Dessensibilizador. Para a confecção dos corpos de prova, 90 incisivos bovinos (n=10) foram utilizados, os quais tiveram suas superfícies vestibulares desgastadas, até a exposição dentinária, de tal forma que, a área de adesão padronizada, tivesse 4 mm de diâmetro. Após a realização dos tratamentos de superfície, onde os Grupos controle eram indicados apenas pela aplicação do sistema adesivo, e os Grupos experimentais, pela aplicação dos agentes dessensibilizantes testados após o condicionamento ácido, foram confeccionados cilindros de resina composta Z-100, com o auxílio de uma matriz bipartida. Os corpos-de-prova foram então armazenados em água destilada a 37°C por 24 horas, e submetidos em seguida ao ensaio de cisalhamento, a uma velocidade do atuador de 0,5 mm/min. Os resultados obtidos foram submetidos à análise de variância, e ao teste de Tukey, ao nível de 5% de significância. Observou-se que houve influência dos agentes dessensibilizantes, quando estes eram aplicados na dentina bovina e interagiam com os sistemas adesivos, sendo que o G. H. F. Dessensibilizador aumentou estatisticamente os valores de resistência de união do Single Bond, e do Prime & Bond 2.1, e o Oxagel não influenciou nos valores de resistência de união dos sistemas adesivos testados. / The objective of this work was it of evaluating in vitro comparatively , the shear bond strength of a resin composed to the bovine dentin in function of the combination of three different adhesive systems and of two different agents dessensitizers. The adhesive systems were used, to know: Single Bond, Master Bond and Prime & Bond 2.1 and the following agents dessensitizers: Oxagel and G. H. F. Desensitizer. For the making of the test bodies, 90 incisive bovine (n=10) they were used, which had its worn away vestibular surfaces, until the exhibition dentin, in such a way that, the area of standardized adhesion, had 4 diameter mm. After the accomplishment of the surface treatments, where the Groups control was just suitable for the application of the adhesive system, and the experimental Groups, for the application of the agents dessensitizers tested after the acid conditioning, cylinders of composed resin were made Z-100, with the aid of a bipartite matrix. The test bodies, they were stored then in water distilled for 37°C by 24 hours, and submitted soon after to the shear bond strength rehearsal, to a crosshead speed of 0,5 mm/min. The obtained results were submitted to the variance analysis, and to the test of Tukey, at the level of 5% of significance. It was observed that there was influence of the agents dessensitizers, when these were applied in the bovine dentin and interagiam with the adhesive systems, and G. H. F. Dessensitizer increased statistically the values of resistance of union of Single Bond, and of the it Prime & Bond 2.1, and Oxagel didn't influence in the values of resistance of union of the tested adhesive systems.
70

Análise dos fotoiniciadores presentes em resinas compostas em função da cor

Alvim, Hugo Henriques [UNESP] 02 March 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-03-02Bitstream added on 2014-06-13T20:12:03Z : No. of bitstreams: 1 alvim_hh_me_arafo.pdf: 508220 bytes, checksum: c8915291af1d596b6c3eb85040d631f6 (MD5) / O objetivo deste estudo foi identificar e quantificar os fotoiniciadores utilizados em diferentes marcas comerciais de resinas compostas em função da cor analisada. Foram utilizadas as resinas compostas: Tetric Ceram A3 (TCA3); Tetric Ceram Translucent (TCT); Filtek Z250 A3 (FZA3); Filtek Z-250 Incisal (FZI); Pyramid Enamel A1 (PEA1); Piramyd Enamel Translucent (PET); Filtek Supreme A3E (FSA3) e Filtek Supreme GT (FSGT). Foram pesados 500mg de cada resina e dissolvidos em 1,0 ml de metanol. As amostras foram centrifugadas para acelerar a sedimentação das partículas inorgânicas. Foram pipetados 0,8 ml da solução sobrenadante que foi armazenada por 72 horas em estufa a 35º C para total evaporação do metanol. Após este período foi feita a ressuspensão com 0,5 ml de metanol e analisados por cromatografia líquida acoplado ao espectrômetro de massa (GC-MS). Os resultados foram comparados a soluções de canforoquinona pura, utilizada como padrão. O teste de T Student, significativo ao nível de 5%, comparou os resultados entre as cores de cada marca comercial. Observou-se menor quantidade de canforoquinona na cor incisal da resina Filtek Z-250 (FZI) quando comparada a cor A3 (FZA3). Por outro lado, as resinas Tetric Ceram e Filtek Supreme apresentaram quantidade de canforoquinona estatisticamente superior nas cores Incisais (TCT e FSGT). Na resina Pyramid Enamel foi encontrada canforoquinona apenas na cor A1 (PEA1), sendo que o fotoiniciador utilizado na cor Translucent não foi identificado. Baseado nos dados obtidos pode-se concluir que uma mesma marca comercial de resina composta pode apresentar diferenças na quantidade e no tipo de fotoiniciador utilizado. / The aim of this study was to identify and quantify the photoinitiators used in different brands of composite resins in function of shade analyzed. It was used the following materials: Tetric Ceram A3 (TCA3); Tetric Ceram Translucent (TCT); Filtek Z250 A3 (FZA3); Filtek Z-250 Incisal (FZI); Pyramid Enamel A1 (PEA1); Piramyd Enamel Translucent (PET); Filtek Supreme A3E (FSA3) e Filtek Supreme GT (FSGT). A small portion (500 mg) of each composite resin was dissolved in 1,0 ml of methanol. The samples were centrifuged to accelerate the inorganic fillers sedimentation. An aliquot (0,8 ml) was stored in vials for 72 hours at 35º C for complete methanol evaporation. After this period was added 0,5 ml of methanol and the samples were analyzed by gas-liquid chromatograph associated to mass spectrometer (GC-MS). The results were compared to pure camphorquinone solutions, used as standart. The results between shades of each commercial brand were compared by T Student test significant at 5%. It was noticed statistical difference in the quantity of camphorquinone between the shades of all tested brands. In Pyramid Enamel was found camphorquinone only in the A1 shade (PEA1). The photoinitiator used in Translucent shade was not identified. Based upon the scientific data presented in this study, it was concluded that the same composite resin brand can present differences in the quantity and type of photoinitiator used.

Page generated in 0.6559 seconds