• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 74
  • Tagged with
  • 74
  • 74
  • 34
  • 30
  • 26
  • 21
  • 16
  • 16
  • 14
  • 14
  • 11
  • 9
  • 9
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Avaliação in vitro da resistência de união em dentina irradiada com o laser de Er:Yag, mediante a aplicação de diferentes sistemas adesivos

Guzmán Sierpinski, Liz Marie [UNESP] 04 March 2002 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:09Z (GMT). No. of bitstreams: 0 Previous issue date: 2002-03-04Bitstream added on 2014-06-13T19:10:21Z : No. of bitstreams: 1 guzmansierpinski_lm_me_arafo.pdf: 1201858 bytes, checksum: 539d83858e78947f655c7f5c650b9e93 (MD5) / O objetivo deste trabalho foi avaliar a influência que o laser de Er:YAG exerce sobre a resistência de união do material restaurador ao substrato dentinário, associando-se a diferentes sistemas adesivos. Para isto foram avaliados 30 molares humanos livres de cárie divididos em três grupos experimentais, utilizando o laser de Er:YAG com uma energia de 260 mJ/10Hz e três grupos controles, em que foram aplicados os seguintes tratamentos: G1) laser, ácido fosfórico a 37%, Excite/Vivadent; G2) controle, ácido fosfórico a 37%, Excite/Vivadent; G3) laser, sistema adesivo Prompt L-pop/Espe; G4) controle, Prompt L-pop;/Espe; G5) laser, ácido fosfórico a 37%, Single Bond/3M; G6) controle, ácido fosfórico a 37%, Single Bond/3M. Todas as amostras foram restauradas com a resina composta Tetric Ceram/Vivadent, termocicladas em 550 ciclos e cortadas, obtendo-se espécimes de mais ou menos 1mm,2 para serem levados a uma Máquina de Testes Universal onde foi realizado o ensaio de microtração. Os tipos de fraturas ocorridos foram analisados mediante microscopia óptica digital e as fraturas mais representativas foram levadas à microscopia eletrônica de varredura. Os resultados mostraram que o sistema laser de Er:YAG apresentou as menores médias de tensão de ruptura, independente do sistema adesivo utilizado. O sistema adesivo Prompt l-pop mostrou resistência adesiva estatisticamente menor em relação aos outros sistemas adesivos estudados. Não houve diferença estatística entre os sistemas adesivos Single Bond e Excite. A maior parte das fraturas encontradas para todos os grupos foram do tipo adesiva. / The aim of this study is to evaluate the influence of the laser Er:YAG to the junction resístance between the tooth surface and the restorative material , using different adhesives . For this study were used 30 human healthy molars, divided in three experimental groups and three control groups. The experimental groups were exposed to a laser of Er:YAG with 260 mJ/10Hz of energy. The six groups were: G1) laser, phosforic acid at 37%, Excite/ Vivadent. G2) control, phosforic acid at 37 % , Excite/ Vivadent. G3) laser, adhesive system Prompt L-pop/ Espe. G4) control, adhesive system Prompt L-pop/ Espe. G5) laser, phosforic acid 37% , Single Bond/ 3M. G6) control, Single Bond/ 3M. All the teeth were restored with the composite Tetric Ceram/ Vivadent. Then thermocycled 550 times and cut in specimens of 1mm2. In these specimens was made a test of micro tensile bond strength in a Universal Test Machine. The fractures were analyzed in a digital optical microscope, and more representative fractures were then analyzed in a electronic microscope. The results revealed that the groups treated with laser Er:YAG presented less tensile bond strengh, independently to the adhesive system used. The adhesive Promp 1-pop presented less tensile bond strengh compared to the other adhesives evaluated. There no was difference between the groups of Single Bond and Excite. The fractures more commun were the adhesive type.
72

Avaliação in vitro da microinfiltração marginal e análise da fenda marginal cervical através da microscopia eletrônica de varredura, em restaurações de classe V de resina composta. Efeito dos sistemas adesivos e técnica de preparo cavitário

Orbegoso Flores, Victor Humberto [UNESP] 07 May 2001 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:27Z (GMT). No. of bitstreams: 0 Previous issue date: 2001-05-07Bitstream added on 2014-06-13T19:41:17Z : No. of bitstreams: 1 orbegosoflores_vh_dr_arafo.pdf: 838219 bytes, checksum: 839e8fda83a571e900cce3e586d69abb (MD5) / O objetivo deste trabalho foi avaliar a formação de fendas marginais cervicais através da microscopia eletrônica de varredura, assim como, a microinfiltração marginal em preparos de classe V. foram utilizadas duas técnicas de preparo: P1 utilizando fresa carbide no 245 e P2 que utilizou o jato de ar abrasivo Mach 4.0 (80psi de pressão, 27 æm de tamanho de partícula). O tamanho das cavidades foi padronizado com 1,5 mm de profundidade, 2,0 mm de altura e 3,0 mm de largura. Os materiais utilizados foram: G1 -Optibond solo Plus, G2 - Prime & BondNT e G3 - Scotchbond Multiuso Plus (grupo controle), a resina composta Point 4 utilizada para restaurar as cavidades foi padronizada para todas as restaurações. Foram utilizados 42 dentes molares hígidos divididos em 3 grupos de 14 cada, utilizando a face vestibular e lingual sendo que os preparos mostraram a margem oclusal em esmalte e a margem cervical em cemento/dentina. Após as restaurações serem confeccionadas foram armazenadas em água deionizada durante 24 horas, para posteriormente realizar os procedimentos de acabamento e polimento, a seguir os dentes foram isolados com araldite e esmalte para unha e submetidos a testes de ciclagem térmico (400 ciclos)e imediatamente imersos numa solução de nitrato de prata, durante 2 horas, removidos, lavados e colocados numa solução fotoreveladora durante 16 horas. Nessas condições os dentes foram limpos e seccionados no sentido mésio/distal obtendo duas metades as quais por sua vez foram seccionadas no sentido vestíbulo lingual dividindo as restaurações pela metade. Assim, uma metade da restauração foi avaliada através da lupa esteroscópica para observar a microinfiltração e a outra metade preparada e metalizada para ser avaliada através da microscopia eletrônica de varredura. A análise estatística aplicada aos resultados permite concluir que... . / The aim of this study was to evaluate the formation of cervical gap with SEM, and the marginal microleakage in cavities class V. There were used two techniques for the preparations: P1 using a carbide # 245 and P2 using abrasive air Mach 4.0 (80 psi of preasure, 27nm measurement of the particle). The measurements of the cavities were standardized in 1.5mm of deepness, 2,0mm of highness and 3,0mm of lengthiness. The materials used were: G1 Optibond Solo Plus, G2 Prime & Bond NT and G3 Scotchbond Multiuso Plus (control group), it was used the composite Point 4 as the restorative material for all cavities. Forty-two healthy molars, divided in three groups of 14 each one, were used. Cavities were prepared in the buccal and lingual faces, its occlusal margin was in enamel and its cervical margin was in dentin/cement. After that finishing and polishing was made. Teeth were isolated with analdite and nail varnish and thermocycled (400 times). The preparations were dyed with silver nitrate for two hours. Preparations were stored in a photo developing solution for 16 hours. After that time teeth were cleaned and cut (buccal/lingual) Half of the preparation was observed in a stereoscopic microscope and the other half in a SEM. Results: 1.Preparations with abrasive air had a bigger gap; 2.Adhesive systems do not eliminate the formation of gaps; 3.Best results were found in the group prepared with bur and the adhesive Optibond Solo Plus, with a cervical gap 0,84nm, and in the other hand Scotchbond Multiuso Plus showed marginal gaps of 6,36nm; 4.In the occlusal margin Optibond Solo Plus had more microleakage tha Scotchbond Multiuso Plus and Prime & Bond NT.; 5. In the cervical margin, Optibond Solo Plus had good behavior controlling the marginal microleakage, compared with Scotchbond Multiuso Plus and Prime & Bond that had similar leakage between... (Complete abstract, click electronic address below).
73

Estudo da resistência às forças de cisalhamento de três sistemas condicionantes indicados para a colagem de acessórios ortodônticos

Bertoz, André Pinheiro de Magalhães [UNESP] January 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:55Z (GMT). No. of bitstreams: 0 Previous issue date: 2004Bitstream added on 2014-06-13T20:36:31Z : No. of bitstreams: 1 bertoz_apm_me_araca.pdf: 3969582 bytes, checksum: bceb452a18ac260c5d9321687a89fc4b (MD5) / Os recentes materiais de colagem dos acessórios ortodônticos têm visado reduzir o tempo de trabalho do clínico, simplificando o procedimento do condicionamento ácido por meio dos sistemas adesivos autocondicionantes. Todavia, as qualidades adesivas desses materiais ainda demandam ser avaliada. Assim, o presente estudo objetivou avaliar a resistência às forças de compressão de três sistemas adesivos. Cento e oitenta incisivos inferiores bovinos foram seccionados e incluídos em matrizes de resina acrílica, nos quais acessórios ortodônticos foram colados com os sistemas Transbond XT (2 grupos de 30), Transbond XT Plus Self Etching Primer (2 grupos de 30) e Tyrian (2 grupos de 30). Para cada sistema, os testes de resistência foram realizados imediatamente (30 dentes) e 24 horas (30 dentes) após a colagem, em uma máquina de ensaio Versat 2000 (Pantec), utilizando célula de carga de 500 Kgf com uma velocidade de 1mm/minuto, de acordo com a literatura. Os sistemas convencional Transbond XT, Transbond XT Self Etching Primer e Tyrian apresentaram, respectivamente, valor médio de resistência à compressão de 7,43, 7,09 e 3,41 MPa no tempo imediatamente após a colagem, e 7,42, 8,81, 5,35 MPa no tempo 24 horas após a colagem, sendo as diferenças estatísticas significantes ao nível de 5% entre os grupos Tyrian e Transbond para ambos os tempos de estudo. Concluiu-se que o material Tyrian apresentou resistência à compressão significativamente inferior em relação aos grupos Transbond que foram similares. / Recent orthodontic bonding materials have aimed to reduce the working time of the clinician, by simplifying the acid etching procedure by applying self-etching primer adhesive systems. However, the adhesion quality of these materials still demands investigation. Thus, the present study aimed to evaluate the bond strengths of three different adhesive systems. A hundred and eighty bovine lower incisors were cut and embebbed in acrylic resin matrices, in which orthodontic brackets were bonded with Transbond XT (2n = 60), Transbond XT Self Etching Primer (2n = 60) e Tyrian (2n = 60). For each composite, bond strength tests were executed immediately (n = 30) and 24 hours (n = 30) after the bonding, in the assay machine Versat 2000 (Pantec), by applying 500 Kgf of load at 1mm/min of velocity. Transbond XT, Transbond XT Self Etching Primer and Tyrian presented, respectively, average values of bond strength of 7.43, 7.09 and 3.41 MPa at the time immediately, and 7.42, 8.81 and 5.35 MPa at 24 hours after the bonding, where differences were statistically significant at 5% between Tyrian and Transbond groups at both observation times. It was concluded that Tyrian was the material that presented significant lower bond strength with regard to Transbond groups that were similar.
74

Efeito da ciclagem mecânica sobre a resistência de união de pinos intra-radiculares de fibra cimentados com resina à dentina

Soares, Luiz Felipe Valandro [UNESP] 09 December 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-12-09Bitstream added on 2014-06-13T19:44:48Z : No. of bitstreams: 1 soares_lfv_dr_sjc.pdf: 2172167 bytes, checksum: afe324626620aad27736c29fa48ab77b (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo avaliou o efeito da ciclagem mecânica sobre a resistência de união de pinos intra-radiculares de fibra cimentados com resina à dentina. As hipóteses desse trabalho são que a resistência adesiva não varia após o teste de fadiga e também não varia em função do tipo de pino de fibra. A parte coronária de 60 dentes humanos unirradiculares foi seccionada, obtendo-se espécimes (sp) de 16mm, que foram submetidos à instrumentação endodôntica e então 30 sp foram preparados (12mm) para receber um pino de fibra de quartzo (D.T. Light-Post) [DT] e 30 foram preparados para um pino de fibra de vidro (FRC Postec Plus) [FRC]. Os pinos foram cimentados (All-Bond + cimento resinoso Duolink) e a parte radicular dos sp foi embutida em resina epóxica até 3mm da porção cervical. Foram constituídos 6 grupos (n=10), considerando o tipo de pino de fibra e o regime de ciclagem mecânica (carga: 50 N; 45° em relação ao longo eixo do sp; freqüência: 8Hz): G1- DT + sem ciclagem; G2- DT + 20.000 ciclos; G3- DT + 2.000.000 ciclos; G4- FRC + sem ciclagem; G5- FRC + 20.000 ciclos; G6- FRC + 2.000.000 ciclos. Os sp foram então seccionados perpendicularmente ao longo eixo do sp,obtendo-se fatias de aproximadamente 2mm (4 secções / sp) que foram submetidas ao ensaio de push-out em máquina de ensaio universal (1mm.min-1). A média de resistência adesiva das repetições de cada espécime foi obtida e os dados (n=10) foram submetidos à análise estatística (a=0,05). A ANOVA mostrou que: (a) as resistências adesivas do pino DT (7,12 l 2,20 MPa) e do pino FRC (6,87 l 2,12 MPa) foram estatisticamente semelhantes entre si (P=0,665); (b) os valores obtidos para a condição sem ciclagem (6,96 l 2,44 MPa), 20.000 (6,99 l 2,08 MPa) e 2.000.000 (7,02 l 2,00 MPa) foram similares estatisticamente (P=0,996); (c) os 6 grupos foram estatisticamente semelhantes entre si (P=1,000)... / This study evaluated the effect of the mechanical cycling on the bond strength of fiber posts resin bonded to root dentin. The tooth crown of the 60 single-rooted human teeth was cut, leaving a 16-mm long root specimens (sp) that were endondontically treated and the space prepared in 12mm. Thirty sp received a quartz fiber post (D.T. Light-Post) and 30 sp received a glass fiber post (FRC Postec Plus). The posts were resin luted in the post space and each sp was embedded with epoxy resin (resin 285, Schaller, Florence, Italy) in a PVC cylinder (height: 25 mm, diameter: 10 mm). Sp were divided into 6 groups, considering the fiber post type and number of the mechanical cycles (load: 50 N; angle of 45°; frequency: 8Hz): G1- DT + without cycling; G2- DT + 20,000 cycles; G3- DT + 2,000,000 cycles; G4- FRC + without cycling; G5- FRC + 20,000 cycles; G6- FRC + 2,000,000 cycles. The sp were cut perpendicular to their long axis, to form 2-mm-thick disk-samples (4 sections / sp), which were submitted to the push-out test (1mm.min-1). The mean bond strength values were calculated for each tooth (n=10) and data were statistical analyzed (a=.05). ANOVA revealed that: (a) the bond strengths of DT (7,12 l 2,20 MPa) and of FRC (6,87 l 2,12 MPa) were statistically similar (P=0,665); (b) the mean values for the without cycling groups (6,96 l 2,44 MPa), 20,000 cycles groups (6,99 l 2,08 MPa) and 2,000,000 cycles groups (7,02 l 2,00 MPa) were not statistically different (P=0,996); (c) the 6 groups were not statistically different (P=1,000). It was concluded that the mechanical cycling did not affect the bond strength of two fiber posts resin bonded to dentin.

Page generated in 0.0905 seconds