Spelling suggestions: "subject:"adhesive lemsystems"" "subject:"adhesive atemsystems""
11 |
"Resistência de união, ao ensaio de microtração, de selante e sistemas adesivos aplicados em superfícies oclusais de molares decíduos" / Micro-tensile bond strength of sealant and adhesive systems applied on occlusal surfaces of primary molars.Ramires-Romito, Ana Cláudia Durante 31 March 2005 (has links)
O objetivo deste estudo foi avaliar a resistência de união, ao ensaio de microtração, de selante (Clinpro, 3M) e sistemas adesivos (OptiBond FL, Kerr; OptiBond Solo, Kerr; OptiBond Solo Self-Etch Adhesive System (SE), Kerr) aplicados em superfícies oclusais de molares decíduos (n=32). Os produtos avaliados foram testados após serem aplicados de acordo com as recomendações dos fabricantes e após contaminação da superfície oclusal com saliva. Após armazenagem em água por 24h a 37ºC, cada dente foi secionado no plano mésio-distal e perpendicularmente à interface de união para obtenção de corpos-de-prova em forma de palito com seção transversal retangular e área aproximada de 0,6 mm 2 . Cada corpo-de-prova foi submetido ao teste de tração em máquina de ensaio universal a uma velocidade de 0,5 mm/min e os fragmentos armazenados para análise posterior do padrão de fratura em microscopia eletrônica de varredura. As fraturas foram classificadas em: adesiva mista, tipo 1 (fratura tanto de material restaurador, isto é associação de adesivo/resina composta, como do esmalte e o substrato predominante foi esmalte); adesiva mista, tipo 2 (fratura tanto de material restaurador como do esmalte e o substrato predominante foi o material restaurador); adesiva mista, tipo 3 (fratura tanto de material restaurador como do esmalte e houve distribuição homogênea de ambos); mista tipo 4 (fratura apenas de material restaurador, isto é, adesivo associado à resina composta) e; coesiva tipo 5 (fratura coesiva exclusivamente de um do substratos sendo esmalte ou resina composta). A análise estatística dos dados obtidos, relativos à resistência de união, usou como unidade experimental o dente. Os palitos perdidos em cada grupo foram incluídos no cálculo de resistência de cada dente. A contaminação salivar não influe nciou a perda de palitos. Não houve associação entre o padrão de fratura e os valores de resistência de união. As fraturas foram predominantemente mistas, não foi observada fratura coesiva exclusivamente de esmalte ou resina composta. Para os sistemas adesivos testados, nenhuma diferença significante foi observada entre os grupos com contaminação salivar ou não. OptiBond FL (34,5 ± 2,2 MPa) e Clinpro (45,1 ± 3,2 MPa) apresentaram valores de resistência de união similares e significativamente maiores do que o OptiBond Solo Plus (19,1 ± 2,3 MPa) e OptiBond Solo SE (9,8 ± 2,3 MPa) que foram equivalentes entre eles (p > 0,05). / The aim of this study was to evaluate the micro-tensile bond strength (mTBS) of a conventional sealant (Clinpro, 3M) and adhesive systems (OptiBond FL, Kerr; OptiBond Solo, Kerr; OptiBond Solo Self-Etch Adhesive System (SE), Kerr) on occlusal surface of primary molars (n=32). Sealant and adhesives were tested under manufacturers specifications and after contamination of the bonding site with saliva. After storage in distilled water at 37 º C for 24 h, the specimens were longitudinally sectioned perpendicular to the adhesive interface. Stick shape samples with cross-sectional areas of about 0.6 mm 2 were obtained and subjected to a tensile force in a universal testing machine at a crosshead speed of 0.5 mm/min. The bond failure modes were evaluated at scanning electron microscope and classified as following: mixed, type 1 (with cohesive failure of the neighboring substrates, wherein enamel was predominant); mixed, type 2 (with cohesive failure of the neighboring substrates, wherein adhesive/resin composite was predominant); mixed, type 3 (with cohesive failure of the neighboring substrates, wherein enamel and adhesive/resin composite was equally distributed); mixed, type 4 (with cohesive failure of the neighboring substrates, where there was only adhesive and resin composite, with none enamel fracture); cohesive, type 5 (failure exclusive within enamel or resin composite). The mean value of bond strength was calculated for each of the four teeth used per group, meaning that the experimental unit was the tooth. These were averaged to express the mean bond strength for every material at each group. The specimens lost due to pre-testing failure were included in the calculus of the mTBS of each tooth. Moisture did not influence sticks loss. There was not any association between failure mode and values of mTBS. The majority of fractures were mixed, none cohesive failure of enamel or composite resin was observed. For the tested adhesive systems no significant difference was observed between the groups under either saliva contamination or not. OptiBond FL (34.5 ± 2.2 MPa) and Clinpro (45.1 ± 3.2 MPa) showed similar values of mTBS and significantly higher than OptiBond Solo Plus (19.1 ± 2.3 MPa) and OptiBond Solo SE (9.8 ± 2.3 MPa) that were equivalent to each other (p>0.05).
|
12 |
Efeito da variabilidade regional do substrato dentinário e modo de aplicação de sistemas adesivos nas propriedades mecânicas da camada adesiva / Effect of the regional variability of dentinal substrate and modes of application of adhesive systems in the mechanical properties of the adhesive layerMendes, Yasmine Bitencourt Emilio 11 February 2010 (has links)
Made available in DSpace on 2017-07-24T19:22:10Z (GMT). No. of bitstreams: 1
Yasmine Bitencourt Emilio Mendes.pdf: 6295050 bytes, checksum: ec73165b3475fb2d502d87ebf6e6717e (MD5)
Previous issue date: 2010-02-11 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim of this study was to assess the effect of different modes of application of a conventional adhesive system AdperTM Single Bond [SB] and of two self-etch adhesives AdperTM SE Plus [SE] and AdheSE® [AD] and influence of dentin depth on mechanical properties of hardness and elastic modulus of adhesive layer using the nanoindentation technique. The surfaces occlusal of 48 caries-free human third molars were removed and the smear layer standardized for the obtaining of a flat superficial dentin surface, in two levels: superficial dentine (DS) or deep dentine (DP). The adhesives were applied on the dentin surface in two layers, under active (AA) or passive (PA) application and photoactivated (10 s / 500 mW/cm2). After composite build-ups were constructed incrementally and were stored in water by 24 h. The teeth were sectioned in perpendicular direction to obtain specimens in form of
bonded sticks with a cross-sectional area of 0.8 ± 0.1mm2, separating the central bonded sticks of each tooth for they be fastened in sample holder and metallographic polishing. The test of nanoindentation was made on composite resin, adhesive system and dentin regions. The results of hardness and elastic modulus (GPa) of adhesive layer were analyzed by a three-way ANOVA and Tukey’s multiple comparison tests (α=0.05) and also took place the two-way ANOVA for each adhesive separately. The mean and standard deviation of hardness and elastic modulus values of composite resin (GPa) were respectively (0.94 ± 0.05) and (13.41 ± 0.52). In dentin, the hardness was (0.89 ± 0.06) and the elastic modulus (17.51 ± 0.71). In the adhesive layer, the highest hardness (0.32 ± 0.02) and elastic modulus (5.54 ± 0.47) of SB were obtained in DS group. The elastic modulus in the adhesive layer of SE (4.11 ± 0.10) was lowest in AA group. For the adhesive layer of AD, just the mode of application was statistically significant (p=0.0041), being AA (0.29 ±
0.01) larger than PA (0.26 ± 0.01) (p=0.0042). It was concluded that: 1) passive application in superficial dentine got greaters values of hardness and modulus of
elasticity of the SB and of SE, 2) the active application in deep dentine resulted in bigger values of the properties in study of SB, 3) active application significantly influenced the values of hardness in the area of the adhesive layer of the AD ones in
such a way in superficial dentine how much in deep, but didn’t influence the modulus. / O objetivo deste trabalho foi avaliar o efeito da forma de aplicação do sistema adesivo convencional AdperTM
Single Bond 2 [SB] e dos sistemas adesivos
autocondicionantes AdperTM SE Plus [SE] e AdheSE® [AD] e da profundidade dentinária nas propriedades mecânicas de dureza e módulo de elasticidade da
camada adesiva por meio do teste de nanoindentação. As superfícies oclusais de 48 terceiros molares humanos hígidos foram seccionadas e a smear layer padronizada
para a obtenção de uma superfície dentinária plana, em dois níveis: dentina superficial (DS) ou dentina profunda (DP). Os adesivos foram aplicados sobre a superfície dentinária em duas camadas de forma ativa (AA) ou forma passiva (AP) e fotoativados (10 s / 500 mW/cm2). Em seguida, foram restaurados incrementalmente
e armazenados em água destilada por 24h. Os dentes foram seccionados em eixos “x” e “y” para obtenção de espécimes em forma de palitos de aproximadamente 0,8
+ 0,1 mm2 de secção transversal, separando o palito central de cada dente para serem fixados em porta-amostra e polidos metalograficamente. O teste de
nanoindentação foi realizado nas regiões da resina composta, camada adesiva e dentina. Os valores de dureza e módulo de elasticidade (GPa) da camada adesiva foram submetidos a uma análise de variância de três fatores e ao teste de Tukey para contraste das médias (α=0,05), e também realizou-se a análise de variância de 2 fatores para cada adesivo isoladamente. As médias e os desvios padrões da dureza e do módulo de elasticidade (GPa) da resina composta foram
respectivamente (0,94 ± 0,05) e (13,41 ± 0,52). Em dentina, a dureza foi (0,82 ± 0,06) e o módulo de elasticidade (17,51 ± 0,71). Para o grupo do SB na camada adesiva, os maiores valores de dureza (0,32 ± 0,02) e módulo de elasticidade (5,54 ± 0,47) foram obtidos no grupo DS. O módulo de elasticidade da camada adesiva do SE (4,11 ± 0,10) foi menor para o grupo AA. Para a região da camada adesiva do AD, apenas a forma de aplicação foi estatisticamente significante (p=0,0041), sendo a AA (0,29 ± 0,01) maior que a AP (0,26 ± 0,01) (p=0,0042). Concluiu-se que: 1)
aplicação passiva em dentina superficial obteve maiores valores de dureza e módulo de elasticidade do SB e do SE, 2) a aplicação ativa em dentina profunda resultou em
maiores valores das propriedades em estudo do SB, 3) aplicação ativa influenciou significativamente os valores de dureza na região da camada adesiva do AD tanto
em dentina superficial quanto em profunda, porém não influenciou o módulo de elasticidade.
|
13 |
Infiltração marginal em cavidades de classe V. Efeito de sistema adesivo e preparo cavitário /Araújo, Taylane Soffener Berlanga de. January 2005 (has links)
Orientador: Maria Salete Machado Cândido / Banca: Edson Alves de Campos / Banca: Luís Alberto Plácido Penna / Banca: José Roberto Cury Saad / Banca: Marcelo Ferrarezi de Andrade / Resumo: Este estudo teve por objetivo analisar in vitro a influência de dois sistemas adesivos resinosos, sendo um autocondicionante de dois passos (Clearfil SE Bond 2) e um convencional também de dois passos (Master Bond), bem como o tratamento das margens cavitárias no controle da microinfiltração marginal. Preparos cavitários de classe V foram executados na face vestibular em 80 dentes anteriores bovinos previamente extraídos, divididos em oito grupos (n=10). O grau de infiltração marginal foi avaliado por penetração do agente traçador (Nitrato de Prata (AgNO3) a 50%) nas paredes incisal e cervical por meio de um "Software-Image Tool", no qual se mede o grau de infiltração em micrômetros e, portanto, análise quantitativa, os resultados submetidos à Análise de Variância seguida do teste de Tukey para observação das diferenças, concluindo-se que: a) os sistemas adesivos apresentaram estatisticamente o mesmo comportamento; b) existe diferença estatisticamente significante entre as técnicas de preparos utilizados sendo que os preparos realizados nos Grupo I e Grupo II, bem como nos Grupos VII e VIII, apresentaram comportamento semelhante e os melhores resultados para redução da microinfiltração; c) os preparos do Grupo III e Grupo IV apresentaram maiores índices de microinfiltração marginal, no entanto, semelhantes aos Grupos V e VI; d) a região cervical apresentou maior nível de microinfiltração quando comparada com a região incisal. / Abstract: This study aimed to analyse in vitro the influence of two resinous adhesive systems: one self-etching of two steps (Clearfil SE Bond 2) and one also conventional of two steps (Master Bond), as well as the treatment of the cavity margins in the marginal microleakage control. Cavity preparations of class V were carried out on the buccal surface of 80 bovine anterior teeth, previously extracted, divided into eight groups (n=10). The marginal leakage degree was evaluated by the penetration of the tracer agent (Silver Nitrate (AgNO3) at 50%); on the incisor and cervical walls through a Software-Image Tool that measures the leakage degree in micrometers and, therefore, quantitative analysis, which results were subjected to the Variance Analysis and afterwards to the Tukey's test in order to observe the differences it was possible to conclude that: a) the adhesive systems presented statistically the same behaviour; b) there is a statistically meaningful difference between the preparation techniques that were used and the preparations that were carried out in Group I and Group II, as well as Groups VII and VIII, that presented similar behaviour and the best results for the reduction of microleakage; c) the preparations of Group III and Group IV presented higher rates of marginal microleakage, however, they were similar to Groups V and VI; d) the cervical region presented higher level of microleakage comparing to the incisor region. / Doutor
|
14 |
Efeito de adição de rodamina B e fluoresceína sódica a sistemas adesivos não simplificados: aspectos fotofísicos e físico-químicos / Effect of addition of rhodamine B and fluorescein to conventional etch-and-rinse and self-etching adhesive systems: photophysical and physical-chemical aspectsOdair Bim Junior 30 May 2017 (has links)
A adição de corantes fluorescentes a adesivos odontológicos possibilita a investigação da distribuição espacial desses materiais na interface dente-restauração, utilizando-se a microscopia confocal de varredura a laser (MCVL). A literatura indica falta de padronização na aplicação de agentes fluorescentes com tal finalidade. Esse estudo sistematizou estratégias para a adição de rodamina B (RB) e fluoresceína sódica (FS) a um sistema adesivo convencional de três passos, Adper Scotchbond Multi-Purpose (MP), e um autocondicionante de dois passos, Clearfil SE Bond (SE), considerados padrão-ouro na Odontologia. Os objetivos principais foram (a) determinar a menor faixa de concentrações de RB e FS necessária para produzir imagens satisfatórias da interface dentina-adesivo e (b) avaliar o efeito da adição desses corantes sobre algumas propriedades das resinas. Os adesivos foram marcados com RB ou FS em concentrações decrescentes (0,5, 0,1, 0,02 e 0,004 mg/mL) por meio de um método de dispersão semidireto. O comportamento fotofísico/ fluorescente dos adesivos marcados foi investigado por espectroscopia de fotoluminescência e MCVL. Paralelamente, avaliaram-se os adesivos quanto ao grau de conversão (GC) e ao ângulo de contato (AC). Tanto os resultados de GC como os de AC foram submetidos à análise de variância com dois fatores (adesivo e tratamento) com = 0,05, seguida de teste post-hoc de Tukey. Os máximos comprimentos de onda de emissão e de excitação da RB e da FS foram influenciados pelo meio polimérico e pela concentração de corante de modo geral. A MCVL preliminar de amostras de adesivo polimerizado, realizada sob condições experimentais padronizadas, mostrou que o comportamento fluorescente da RB em MP e SE foi muito semelhante na mesma concentração de corante, mas o mesmo não pôde ser dito do comportamento da FS, que foi notavelmente inferior no adesivo autocondicionante, SE, na concentração mais alta. Em dentina, os adesivos preparados com RB nas concentrações-alvo de 0,1 e 0,02 mg/mL apresentaram fluorescência ótima; já aqueles preparados com 0,004 mg/mL produziram fraco sinal. Adesivos preparados com FS a 0,5 mg/mL apresentaram ótima fluorescência na interface de adesão, enquanto que concentração menor desse corante não produziu sinal suficiente. Padrões morfológicos aparentemente atípicos foram observados na interface de adesão, quando da associação do adesivo SE com o corante FS. A adição de RB e FS nas quatro concentrações indicadas aos adesivos MP e SE não afetou o GC nem o AC em comparação com os grupos de controle correspondentes. Em suma, a RB mostra-se um corante mais versátil que a FS na avaliação morfológica das interfaces dentina-MP e dentina-SE via MCVL. A menor faixa de concentrações de RB nos adesivos MP e SE, na qual é possível produzir imagens satisfatórias das interfaces, situa-se entre 0,10,02 mg/mL. Já o corante FS deve ser adicionado a esses adesivos a pelo menos 0,5 mg/mL para produzir níveis de fluorescência satisfatórios na interface de adesão. A não ocorrência de efeitos deletérios sobre a polimerização e a molhabilidade das resinas estabelece uma margem de segurança para a incorporação desses agentes fluorescentes (em concentração 0,5 mg/mL) nesses sistemas monoméricos. / The addition of fluorescent dyes to dental adhesives makes it possible to investigate the spatial distribution of such resin-based materials in the tooth-restoration interface, using confocal laser scanning microscopy (CLSM). Literature indicates a lack of standardization on the application of fluorescent agents for this purpose. This work presents strategies for adding rhodamine B (RB) and fluorescein sodium salt (FS) to a three-step etch-and-rinse adhesive system, Adper Scotchbond Multi-Purpose (MP), and a two-step self-etching one, Clearfil SE Bond (SE), both regarded as \"gold standard\" in restorative dentistry. The main objectives were (a) to determine the lowest range of RB and FS concentrations required to produce suitable images of the dentin-adhesive interface via CLSM and (b) to investigate potential effects of addition of these dyes on some resin properties. The adhesives were labeled with RB or FS at decreasing concentrations (0.5, 0.1, 0.02 and 0.004 mg/mL) by means of a semi-direct dispersion method. The photophysical/fluorescent behavior of the labeled resins was investigated by photoluminescence spectroscopy and by CLSM. The adhesives were also investigated with regards to the degree of conversion (DC) and contact angle (CA). A two-way ANOVA of adhesive and treatment was conducted on DC and CA separately, followed by Tukeys test. The maximum emission and excitation wavelengths of RB and FS were influenced by the host polymer and the dye concentration in general. The preliminary CLSM of cured adhesive samples, performed with standardized settings, showed that the fluorescent behavior of RB in MP and SE was very similar in the same dye concentration, unlike the behavior of FS, which was lower in the self-etching adhesive for the highest dye concentration. In dentin, the adhesives prepared with RB at the target concentrations of 0.1 and 0.02 mg/mL presented optimal fluorescence; those with 0.004 mg/mL produced poor signal. Adhesives prepared with FS at 0.5 mg/mL presented optimal fluorescence at the bonding interface, whereas lower concentrations of FS did not produce sufficient signal. Atypical morphological features were observed at the bonding interface, when adhesive SE was used with FS. The addition of RB and FS at the four decreasing concentrations to adhesives MP and SE did not affect DC or CA compared to the corresponding controls. In short, RB is more versatile than FS for the morphological characterization of dentin-MP and dentin-SE interfaces via MCVL. The lowest range of RB concentrations in adhesives MP and SE that can produce suitable images of the bonding interface lies between 0.10.02 mg/mL. The dye FS should be added to these adhesives at 0.5 mg/mL at least to produce satisfactory fluorescence levels at the bonding interface. Since negative effects on polymerization and wettability of the resins were not observed, the use of RB and FS (in concentration 0.5 mg/mL) together with MP and SE should be reliable in terms of resin properties.
|
15 |
Resistência ao cisalhamento de bráquetes ortodônticos após envelhecimento artificial acelerado / Shear bond strength of orthodontic brackets after accelerated artificial agingBrahim Drubi Filho 09 December 2011 (has links)
O propósito deste estudo foi comparar a resistência ao cisalhamento (RC) e o índice de remanescente adesivo (IRA) após Envelhecimento Artificial Acelerado (EAA) de bráquetes ortodônticos metálicos fixados com compósitos autopolimerizável (Concise Ortodôntico - CS, 3M Unitek) e fotoativado (Transbond Plus Color Change - TPCC, 3M Unitek) com diferentes tratamentos de superfície do esmalte. Foram selecionados 60 pré-molares humanos recém extraídos, que tiveram suas raízes embutidas em resina acrílica ativada quimicamente de forma que a face vestibular ficasse perpendicular ao plano horizontal. Estas foram limpas com pedra pomes e água por 10 segundos, lavadas e secas. Os dentes foram separados aleatoriamente em 5 grupos (n=12), segundo o tipo de tratamento de superfície do esmalte, e do compósito utilizado para fixação dos bráquetes: Grupo I - ácido fosfórico a 37% (Dental Gel, Dentsply) e CS; Grupo II - ácido fosfórico a 37% + Primer e CS; Grupo III - ácido fosfórico a 37% e TPCC; Grupo IV - ácido fosfórico a 37% + XT Primer (3M Unitek) e TPCC; e Grupo V Transbond Plus Self Etching Primer - SEP (3M Unitek) e TPCC. Após 24h da colagem dos bráquetes, metade das amostras de cada grupo (n=6) foi submetida ao EAA por 960 horas. Todas as amostras foram submetidas ao ensaio de resistência ao cisalhamento com cinzel em máquina universal de ensaios (DL 200, EMIC) na velocidade de 0,5 mm/min. Após a descolagem dos bráquetes, causada pelo teste de resistência ao cisalhamento, o IRA foi avaliado em lupa (10X) e quantificado a partir de escore (0-3). Os dados foram analisados estatisticamente (2-way ANOVA, Bonferroni, p<0,05) e verificou-se que não houve diferença estatisticamente significante entre os Grupos em função do EAA (p>0,05). Quando comparados os sistemas adesivos utilizados, verificou-se que o Grupo II sem EAA, apresentou a maior média de RC, resultado estatisticamente significante (p<0,05) em relação aos grupos III e V, que apresentou a menor média de RC. Quanto ao IRA, todos os grupos sem EAA apresentaram maior frequência do índice 3. Com EAA, houve aumento de frequência dos índices 1 e 2. Concluiu-se que o EAA não influenciou a RC de bráquetes ao dente, mas diminuiu a área de remanescente adesivo sobre o dente. / The purpose of this study was to compare the shear bond strength (SBS) and the adhesive remnant index (ARI) after Accelerated Artificial Aging (AAA) of metal orthodontic brackets bonded with self-polymerizing (Concise Ortodôntico - CS, 3M Unitek) and light activated (Transbond Plus Color Change - TPCC, 3M Unitek) composites, to enamel with different surface treatments. Sixty recently-extracted human premolars were selected. Their roots were embedded in chemically activated acrylic resin so that the vestibular face was perpendicular to the horizontal plane. They were cleaned with pumice stone and water for 10 seconds, washed and dried. The teeth were randomly separated into 5 groups (n=12), according to the type of enamel surface treatment, and composite used for bracket bonding: Group I - 37% phosphoric acid (Dental Gel, Dentsply) and CS; Group II - 37% phosphoric acid + Primer and CS; Group III - 37% phosphoric acid and TPCC; Group IV - 37% phosphoric acid + XT Primer (3M Unitek) and TPCC; and Group V Transbond Plus Self Etching Primer - SEP (3M Unitek) and TPCC. Twenty-four hours after bracket bonding, half the samples from each group (n=6) were submitted to AAA for 960 hours. All the samples were submitted to shear bond strength testing with a chisel, in a Universal Test Machine (DL 200, EMIC) at a speed of 0.5 mm/min. After bracket debonding caused by the shear bond strength test, the ARI was evaluated under a loupe (10X) and quantified according to a score (0-3). Data were statistically analyzed (2-way ANOVA, Bonferroni, p<0.05) and it was verified that there was no statistically significant difference among Groups as a function of AAA (p>0.05). When comparing the adhesive systems used, it was verified that Group II without AAA showed the highest mean SBS, a statistically significant result (p<0.05) in comparison with Groups III and V, which showed the lowest mean SBS. As regards ARI, all the groups without AAA showed higher frequency of Index 3. With AAA, there was increased frequency of indexes 1 and 2. It was concluded that AAA did not influence SBS of brackets to the tooth, but diminished the area of adhesive remnant on the tooth.
|
16 |
Influência da proporção do HEMA nas propriedades de uma resina adesiva experimentalCollares, Fabrício Mezzomo January 2007 (has links)
O objetivo deste estudo é caracterizar a influência da relação dos componentes hidrófilos de uma resina adesiva experimental em suas propriedades intrínsecas. Para isso, foram adicionados a um sistema polimérico (BisGMA, BisEMA e TEGDMA), diferentes concentrações de HEMA totalizando quatro grupos: 0%, 15%, 30% e 50% de HEMA. As misturas foram caracterizadas quanto à cinética de polimerização através de Fourier Transformed Infrared (FTIR) em tempo real e a taxa de polimerização (RP) foi calculada através da análise de regressão não-linear; resistência coesiva à tração utilizando-se uma máquina de ensaios mecânicos com corpos de prova em forma de ampulheta com área de constrição de 1mm2; e, sorção e solubilidade baseada na normatização ISO 4049. Houve correlação entre o tempo de fotoativação e o grau de conversão para todos os grupos (r2>0.98). O grupo 0% apresentou RPMÁX elevada nos segundos iniciais de fotoativação com, no entanto, uma brusca redução. As adições de 30% e 50% de HEMA determinaram uma RPMÁX do copolímero menor que em 15% e 0%. Não houve diferença entre o grau de conversão final (60s) entre os grupos de 0, 15 e 30%, sendo 59,7%, 61,4% e 55,2% respectivamente. As adições de 30% e 50% de HEMA determinaram a redução da resistência coesiva dos polímeros (p<0,05) quando comparado aos grupos 0% e 15%. Grupos com maiores adições de HEMA apresentaram maiores graus de sorção e solubilidade (p<0,05). Maiores adições de HEMA resultaram em polímeros mais propensos à degradação. / The aim of this study was to characterize the influence of hydrophilic monomers ratios on an experimental adhesive resin properties. Four groups, with 0, 15, 30 and 50% (wt) addiction of HEMA were prepared. Comonomer blends (BisGMA, BisEMA, TEGDMA and HEMA) were analyzed with kinetics of polimerization real time FTIR and the rate of polymerization was calculated by non-linear regression analysis. Ultimate tensile strength was tested using a universal testing machine (Emic) with hour-glass shaped specimens with cross-sectional area 1mm2. Water sorption and solubility tests were based on ISO 4049. For All groups was a positive and strong correlation between light-activation time and degree of conversion (r2>0,98). Group 0% of HEMA showed higher RPMÁX in early seconds with a suddenly decrease. Additions of 30% and 50% of HEMA determined a RPMÁX lower than the comonomer blends with 15% and 0% of HEMA. There was no statistical difference of final degree of conversion of the tested groups, varying from 63% to 67% . The additions of 30% and 50% of HEMA determined reduction of ultimate tensile strength of the polymers formed (p<0,05) when compared to 0% and 15 % of HEMA. Groups with higher additions of HEMA showed higher water sorption and solubility (p<0,05). Higher additions of HEMA resulted in polymers more prone to degradation.
|
17 |
Avaliação da influência do tempo de abertura dos frascos de sistemas adesivos na microinfiltração marginal em cavidades de classe V de dentes restaurados com resina composta.Lago, Cristiana da Costa Libório January 2006 (has links)
Submitted by Suelen Reis (suziy.ellen@gmail.com) on 2013-04-23T15:55:38Z
No. of bitstreams: 1
Dissertação Cristiana Lago.pdf: 2446481 bytes, checksum: c965a72c0cf3e50211e14ec8283d42e5 (MD5) / Approved for entry into archive by Rodrigo Meirelles(rodrigomei@ufba.br) on 2013-05-08T11:45:33Z (GMT) No. of bitstreams: 1
Dissertação Cristiana Lago.pdf: 2446481 bytes, checksum: c965a72c0cf3e50211e14ec8283d42e5 (MD5) / Made available in DSpace on 2013-05-08T11:45:33Z (GMT). No. of bitstreams: 1
Dissertação Cristiana Lago.pdf: 2446481 bytes, checksum: c965a72c0cf3e50211e14ec8283d42e5 (MD5)
Previous issue date: 2006 / O objetivo deste estudo in vitro foi avaliar a influência do tempo de abertura dos frascos de dois sistemas adesivos, à base de acetona e etanol/água, na microinfiltração marginal de restaurações de resina composta. Para reproduzir a rotina clínica, foram estimados o tempo médio de 15 segundos de abertura durante a utilização dos frascos de adesivo em cada procedimento restaurador e a quantidade média de restauração realizada em um consultório, 8 pacientes por dia. Quatro frascos de cada sistema adesivo, Prime & Bond NT(PBNT), Dentsply (à base de acetona) e Adper Single Bond 2 (SB2), 3M ESPE (à base de etanol/água), foram abertos diariamente, em um frequência de 8 vezes de 15 segundos, durante os períodos de 0, 30, 60 e 90 dias. Cento e doze cavidades de classe V, localizadas na junção cemento esmalte, foram preparadas nas faces vestibular e lingual de terceiros molares humanos hígidos e então divididas em oitos grupos nos quais os sistemas adesivos foram assim utilizados: G1: PBNT, nenhum dia de abertura; G2: SB2, nenhum dia de abertura; G3: PBNT, 30 dias de abertura; G4: SB2, 30 dias de abertura; G5: PBNT, 60 dias de abertura; G6: SB2, 60 dias de abertura; G7: PBNT, 90 dias de abertura; e G8: SB2, 90 dias de abertura. Todas as cavidades foram restauradas com resina composta Filtek Z250 (3M ESPE). Após acabamento e polimento, os dentes foram termociclados (500 ciclos à 5ºC + 2º e 55ºC + 2º). Os ápices radiculares foram vedados com resina composta Filtek Z250 e, em seguida, foi feita a impermeabilização com duas camadas de esmalte para unha com margem livre de 1mm ao redor das restaurações. Os dentes foram então imersos em solução de azul de metileno a 0,5%, por 24 horas, à 37ºC. Cada restauração foi seccionada no sentido vestíbulo lingual com disco diamantado em três cortes que foram analisados sob lupa estereoscópica, com o auxílio de um paquímetro digital para a medição da microinfiltração em milímetros. Os resultados foram avaliados estatisticamente através da análise de variância (ANOVA) e pelos testes de Tukey e T de Student. Não houve diferença estatisticamente significante entre os grupos, tanto para o Prime & Bond NT, como para o Adper Single Bond 2, considerando o tempo de abertura dos frascos de adesivos. Entre os diferentes substratos, a microinfiltração foi maior em dentina do que em esmalte (p<0,05). Ao comparar os sistemas adesivos entre si, não houve diferença estatisticamente significante quanto à capacidade de promover o selamento e impedir a microinfiltração. De acordo com as condições experimentais testadas, pôde-se concluir que a abertura dos frascos de adesivo, realizada na rotina de atendimento no consultório odontológico, e a possível volatilização dos solventes presentes nestes sistemas adesivos não promoveram um aumento da microinfiltração nas restaurações de resina composta. / Salvador
|
18 |
Influência do método de preparo cavitário, alta rotação e laser de Er:YAG, sobre a espessura da camada híbrida de diferentes sistemas adesivos, com diferentes filosofias adesivas / Influence of cavity preparation method, high speed turbine and Er:YAG laser, on hybrid layer thickness of different adhesive systemsMarcos de Oliveira Barceleiro 11 October 2006 (has links)
O objetivo deste estudo foi promover uma comparação entre as espessuras de camadas híbridas formadas entre os sistemas adesivos Scotchbond Multi-Uso Plus, Single Bond 2, Prime & Bond 2.1 e Xeno III, e a superfície dentinária, preparada com dois métodos de preparo cavitário, a ponta diamantada montada em turbina de alta rotação, e o laser de Er:YAG, utilizado com dois parâmetros de energia (200 e 400 mJ) e dois parâmetros de freqüência (4 e 6 Hz). Para a realização deste experimento, foram realizados tratamentos superficiais com os dois métodos descritos em fragmentos de dentina superficial aplainada, retirados de vinte terceiros molares humanos recém-extraídos, seguido de preparo da dentina com os sistemas adesivos. Após a aplicação e fotoativação de uma camada de compósito sobre a dentina preparada, os corpos de prova foram cortados, polidos e preparados para visualização em MEV, meio pelo qual foram realizadas cinco medidas da espessura da camada híbrida formada em cada corpo de prova. Os resultados obtidos foram tratados estatisticamente por ANOVA e teste de Student-Newnan-Keuls, em um nível de significância de 95%, e por Kruskal Wallis e Mann Whitney, também em um nível de significância de 95%, através do programa SPSS for Windows release 5.0. A análise foi realizada levando-se em consideração dois fatores de estudo, a presença ou não de camada híbrida e a espessura da camada híbrida. Em relação ao fator espessura da camada híbrida, quando se avaliou o tipo de preparo realizado, a análise estatística por ANOVA e Student-Newman-Keuls levou a formação de quatro grupos homogêneos, sendo Grupo I (ponta diamantada) > Grupo II (Laser 200 mJ / 4 Hz) = Grupo III (Laser 200 mJ / 6 Hz) > Grupo IV (Laser 400 mJ / 4 Hz) > Grupo V (Laser 400 mJ / 6 Hz). Quando se avaliou o tipo de sistema adesivo utilizado, não se encontrou diferença estatisticamente significante. Em relação ao fator presença de camada híbrida, quando se avaliou o tipo de preparo realizado, a análise estatística por Kruskal Wallis e Mann Whitney levou a formação de três grupos homogêneos (Grupo I _ Grupo II = Grupo III = Grupo IV _ Grupo V). Quando se avaliou o tipo de sistema adesivo utilizado, não se encontrou diferença estatisticamente significante. Quando se realizou o cruzamento tipo de preparo x sistema adesivo, a análise estatística mostrou a formação de sete grupos distintos. Pela análise dos resultados obtidos neste estudo in vitro, foi possível concluir que em dentina preparada com ponta diamantada em alta rotação, os quatro sistemas adesivos testados formaram camadas híbridas de formato regular e presentes de forma constante, com espessura média de 2,90 1,71 m, e em dentina preparada com laser de Er:YAG, os quatro sistemas adesivos testados formaram camadas híbridas de formato irregular e presentes de forma intermitente, com espessura média variando entre 0,41 1,00 m e 2,06 2,49 m. Além disso, concluiu-se que o laser de Er:YAG com os parâmetros testados influencia negativamente a formação da camada híbrida, e que os métodos de preparo cavitário influenciam na espessura da camada híbrida. / The objective of this study was to compare the thickness of the hybrid layer formed
using Scotchbond Multipurpose Plus, Single Bond 2, Prime & Bond 2.1 and Xeno III on
dentine surface, prepared with a diamond bur in a high speed handpiece, or prepared with an Er:YAG laser, used with two parameters of pulse energy (200 and 400 mJ) and two
parameters of frequency (4 and 6 Hz). Flat dentine surfaces obtained from twenty third molars human teeth were treated with the two methods, and then were prepared with the dentine adhesive systems, according to manufacturers instructions. After a layer of composite was applied, specimens were sectioned, flattened, polished and prepared for Scanning Electronic Microscopy observation. Five different measurements of hybrid layer thickness were obtained along the bonded surface in each specimen. Results were statistically analyzed using analysis of variance and Student-Newman-Keuls tests (p ≤ 0.05), and using Kruskal Wallis and Mann Whitney tests (p ≤ 0.05). The statistical analysis was made considering two observations parameters, the presence of the hybrid layer, and its thickness. When analyzing the hybrid layer thickness, and comparing the cavity preparation method, four groups were formed, Group I (diamond bur) > Group II (Laser 200 mJ / 4 Hz) = Group III (Laser 200 mJ / 6 Hz) > Group IV (Laser 400 mJ / 4 Hz) > Group V (Laser 400 mJ / 6 Hz). When comparing the dentine adhesive systems, it was not found any statistically significant difference. When analyzing the presence of hybrid layer, and comparing the cavity preparation method, three groups were formed (Group I ≠ Group II = Group III = Group IV ≠ Group V). When comparing the dentine adhesive systems, it was not found any statistically significant difference. When analyzing the hybrid layer thickness, and comparing the cavity preparation method x the dentine adhesive systems, it was found seven different groups. These results showed that the four tested dentine adhesive systems produce a 2.90 1.71 μm hybrid layer in dentine prepared with diamond bur. This hybrid layer was regular and constantly found. In the laser groups, the dentine adhesive systems produced hybrid layers ranging from 0.41 1.00 μm to 2.06 2.49 μm, which were very irregular and were not found constantly. It was also concluded that Er:YAG laser with the parameters used in this experiment, is a negative influence to the hybrid layer formation, and that cavity preparation methods do influence the hybrid layer formation.
|
19 |
Avaliação da dureza superficial de cimentos resinosos após cimentação de pinos de fibra de vidro: efeito de profundidade de polimerização e sistemas adesivosJardim, Patrícia dos Santos [UNESP] 06 April 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0
Previous issue date: 2004-04-06Bitstream added on 2014-06-13T19:01:42Z : No. of bitstreams: 1
jardim_ps_dr_arafo.pdf: 1044832 bytes, checksum: e4dd0c96ad60802f6b6357bc3b691056 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Os pinos pré-fabricados de fibra de vidro têm sido o sistema de escolha para reconstrução de dentes anteriores tratados endodonticamente e o sucesso da cimentação dos pinos de fibra de vidro está associado à cimentação do tipo adesiva, sendo que o agente cimente normalmente utilizado é um cimento resinoso de dupla polimerização, entretanto questiona-se a eficácia dos cimentos de dupla polimerização, principalmente nas regiões muito distantes da fonte de luz, bem como sua compatibilidade química com sistemas adesivos simplificados. O presente trabalho teve como objetivo avaliar a dureza superficial de cimentos resinosos, um quimicamente ativado (Bistite II DC) e um de dupla polimerização (Rely X) em função de diferentes profundidades de polimerização e sistemas adesivos; bem como, formação de camada híbrida quando da cimentação de pino de fibra de vidro no canal radicular de dentes bovinos. Foram utilizados 40 raízes bovinas, as quais foram tratadas endodonticamente e divididas aleatoriamente em 4 grupos de 10 raízes cada de acordo com o cimento resinoso e sistema adesivo utilizado para cimentação do pino de fibra de fivro: (GI) Bistite II DC; (GII) Rely X associado ao Scotchbond Multi-Uso Plus; (GIII) Rely X associado ao Single Bond; (GIV) Rely X associado ao One-Up Bond F. Após 24 horas da cimentação, as raízes foram seccionadas no sentido transversal em três discos radiculares, representando os terços cervical, médio e radicular, com profundidades respectivas de 3,0mm; 6,0mm e 9,0mm. Para realização das medidas de dureza, cada secção radicular foi dividida em quadrantes, nos quais foram realizadas três medidas: (M1) próximo à dentina radicular; (M2) região intermediária; (M3), próximo ao pino de fibra de vidro, cujos resultados foram submetidos à Análise de Variância e Teste de Tukey. Após o Ensaio de Dureza, as amostras foram... . / Fiber posts have been the system of choice for endodontically-treated anterior teeth reconstruction, and the cementation luting success is associated to adhesive-type cementation, being the dual-cure resin cements the most utilized cement. However, the dual-cured cements efficacy is questioned, mainly in the regions distant from the light-cure source, as well as the chemical compatibility to simplified adhesive systems. The aim of the present study was evaluate superficial roughness of resin cements, being one of them chemically activated (Bistite II DC) and the other dual-cured resin cement (Rely X) under different light-cure depths and bond systems; as well as hybrid layer formation in cases of glass fiber post in bovine radicular canal. Forty bovine roots samples were used. These roots were endodontically treated and randomly separated in four groups of 10 roots each according to the resin cement and adhesive system used for glass fiber post cementation.: The groups were divided as follows: (GI) Bistite II DC; (GII) Rely X associated to Scotchbond Multi-Purpose Plus; (GIII) Rely X associated to Single Bond; (GIV) Rely X associated to One-Up Bond F. After 24 hours passed from cementation, roots were sectioned in transversal orientation in three radicular discs, representing the cervical, medium and radicular thirds, with respective depths of 3,0mm; 6,0mm e 9,0mm. For hardness measuring, each radicular section was divided in quadrants. These quadrants were measured three times: (M1) near radicular dentin; (M2) intermediary region; (M3), near glass fiber post. These results were submitted to ANOVA and Tukey Test. After hardness assay samples were submitted to hybrid layer evaluation in Scanning Electron Microscopy and subsequent photomicrography descriptive analysis. From the methodology and... (Complete abstract, click electronic address below).
|
20 |
Análise da resistência adesiva à dentina de diferentes sistemas adesivos pelo teste de microtração e microscopia eletrônica de varreduraMazur, Rui Fernando [UNESP] 10 November 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:27Z (GMT). No. of bitstreams: 0
Previous issue date: 2003-11-10Bitstream added on 2014-06-13T20:41:47Z : No. of bitstreams: 1
mazur_rf_dr_arafo.pdf: 2691655 bytes, checksum: aa6766566238765dc0a1f4d5cb633eda (MD5) / O objetivo deste trabalho foi realizar, in vitro, avaliação da resistência de adesiva pelo teste de microtração de dez sistemas adesivos diferentes. Os sistemas adesivos One Up Bond F - Tokuyama, Clearfil SE Bond - Kuraray, Adper Prompt L-Pop, Single Bond - 3M/ESPE, One Step - Bisco, One Step Plus - Bisco, Prime&Bond NT - Dentsply, Excite - Vivadent, Scotchbond Multi - Uso - 3M/ESPE e All Bond 2 - Bisco. Para a realização do teste foram utilizados quarenta dentes molares hígidos, sendo que destes dentes dez foram utilizados para a microscopia eletrônica de varredura. Para a realização do teste de microtração os dentes foram cortados na superfície oclusal com disco diamantado e posteriormente foram desgastados com discos de lixa. Posteriormente as amostras foram restauradas com os respectivos sistemas adesivos e resina composta Z-100 com tempo de polimerização de 40 segundos cada incremento. Após vinte e quatro horas de armazenagem em temperatura de 37ºC os dentes foram seccionados com disco diamantado com finalidade de obter palitos com área de 1,0 +- 0,2 mm2. Após o corte os palitos foram armazenados em temperatura de 37ºC por vinte e quatro horas e em seguida foram levados para a máquina de ensaio universal EMIC 500 DL onde os palitos foram tracionados com velocidade de 1 mm/min. Os resultados foram analisados pelo através dos testes de normalidade de Lilliefors e de homogeneidade de variância de Bartlett. Quando alguns dos pressupostos não se verificaram, utilizou-se o teste não paramétrico de Kruskal - Wallis. Os resultados obtidos foram em ordem decrescente de 36,73 +- 10,52 para o sistema adesivo One Up Bond F, seguido do sistema de três etapas All Bond 2 com 34,29 +- 12,63 para o sistema adesivo One Step Plus foi de 33,18 +- 11,33 para o sistema Adper Prompt L-Pop de 31,76 +- 11,3, sistema One Step de 29,02 +- 11,28, para o... . / The aim of this study was to analyze the bond strength of ten adhesive systems: One Up Bond F - Tokuyama (OU); Adper Prompt L-Pop - 3M-ESPE (AP); Clearfil SE Bond - Kuraray CO. (SE); Prime Bond NT - Caulk-Dentsply (NT); Single Bond - 3M-ESPE (SB); One Step - Bisco (OS); One Step Plus - Bisco (OP); Excite - Vivadent (EX); Scotchbond Multi - Purpose (SMP) e All Bond 2 - Bisco (AB). Methods: Forty freshly extracted human teeth were transversely wetcut using a diamond disk in order to expose the occlusal dentin surface. Then the adhesive systems were applied according to the manufacturer's instruction. The teeth were restored with composite resin Z-100 (3M) and stored in distilled water at 37ºC for 24 hours. A slow-speed diamond disk was used to prepare microtensile test specimens, with a bonded area of 1,00 +- 0,2 mm2. Each group was composed of thirty sticks, which were stored in distilled water at 37ºC for 24 hours. The sticks were bonded on a universal testing machine at a cross head speed of 1 mm/min. The following results demonstrate values microtensile bond strengths in MPa. Data were statistically analyzed by Kruskal-Wallis Test (p<-0.05). The bond strength values were 36,73 +- 10,52 for One Up Bond F, 34,29 +- 12,63 for All Bond 2, 33,18 +- 11,33 for One Step Plus, 31,76 +- 11,3 for Adper Prompt L-Pop, 29,02 +- 11,28 for One Step, 28,82 +- 14,74 for Single Bond, 28,08 +- 12,09 for Clearfil SE Bond, 26,31 +- 9,02 for Scotchbond Multi - Purpose, 21,35 +- 10,22 for Prime&Bond NT and 19,52 +- 10,08 for Excite. Ten teeth were analysed by SEM and all of them showed resin into the dentin tubules. Most of fractures were adhesive in the composite/teeth interface. One up bond F (OU) resulted in higher bond strength when compared to all the other systems tested and Excite resulted in lower bond strength. Self-etching systems were not statistically... (Complete abstract, click electronic address below).
|
Page generated in 0.0735 seconds