• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 116
  • 87
  • 11
  • 10
  • 9
  • 5
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 270
  • 270
  • 151
  • 88
  • 82
  • 75
  • 71
  • 55
  • 50
  • 43
  • 43
  • 42
  • 40
  • 39
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Regeneração de carvão ativado utilizado para adsorção de pesticida por meio de processos oxidativos avançados. / Regeneration of activated carbon used for adsorption of pesticide by advanced oxidation processes.

Zambrana, Carolina Oliveira 15 May 2013 (has links)
Como os tratamentos convencionais de água e efluentes normalmente não reduzem as concentrações de pesticidas significativamente, torna-se necessário utilizar outros tipos de tratamento associados e uma alternativa é o pós-tratamento empregando carvão ativado (CA) para adsorção desses poluentes. Sua viabilidade econômica está associada ao seu reúso. O desenvolvimento de novas técnicas de regeneração de CA contaminado após uso, como o emprego de Processos Oxidativos Avançados (POA), tem recebido muita atenção. Os POA são caracterizados pela geração de radicais hidroxila (HOo), que são fortes oxidantes capazes de mineralizar uma vasta gama de substâncias, geralmente sem a necessidade de disposicão final. Nesse sentido, no presente trabalho estudou-se a aplicação dos POA baseados na peroxidação assistida por radiação ultravioleta (H2O2/UV) e oxidação promovida por peroximonossulfato de potássio (PMS) para regeneração de CA contaminado com o herbicida amicarbazona. Os processos estudados consistiram de duas etapas: adsorção, contactando-se a solução contendo o herbicida com o CA por um período pré-determinado; e tratamento, empregando os processos H2O2/UV ou PMS. Os resultados para o sistema H2O2/UV indicaram que não houve regeneração do CA, já que não se observou aumento na capacidade de adsorção após ciclos de regeneração consecutivos. Para o processo baseado em PMS, a regeneração é aparentemente efetiva. O tempo de regeneração, para uma razão oxidante/contaminante mais alta, mostrou-se importante no processo oxidativo PMS, já que maiores tempos de contato entre o oxidante e o carvão contaminado resultaram em uma melhora, mesmo que pequena, na capacidade do CA em adsorver a amicarbazona. / Conventional water and wastewater treatment processes usually do not significantly reduce the concentrations of pesticides, thus other types of treatment are necessary. An alternative is the use of activated carbon (AC) for the adsorption of these pollutants, although its economic viability is directly associated with its reuse. The development of new techniques for regenerating AC contaminated after usage, as the Advanced Oxidation Processes (AOP), have received much attention. AOP are characterized by the generation of hydroxyl radicals (HOo), which are strong oxidants able to mineralize a wide range of substances, often without the need for final disposal. Thus, the present study investigated the application of AOPs based on the ultraviolet-assisted peroxidation (H2O2/UV) and oxidation promoted by potassium peroxymonosulfate (PMS) for the regeneration of AC contaminated with the herbicide amicarbazone. The processes studied consisted of two steps: adsorption, by contacting the solution containing the herbicide with the AC for a certain period of time; and treatment, using the H2O2/UV or PMS processes. The results for the H2O2/UV system showed a maintenance of the AC´s adsorption capacity, since there was observed a constant adsorption capacity after consecutive regeneration cycles. For the PMSbased process, regeneration appears to be more effective with time exposure associated with higher oxidant/contaminant ratios, shown to be the most important factor in this case, since longer contact periods between the oxidant and the contaminated activated carbon resulted in an improvement, however small, in the ability of AC to adsorb amicarbazone.
42

Tratamento combinado de lixiviado de aterro sanitário e esgoto doméstico utilizando ozônio

Schons, Alisson 24 February 2016 (has links)
Submitted by JOSIANE SANTOS DE OLIVEIRA (josianeso) on 2017-05-25T11:43:55Z No. of bitstreams: 1 Alisson Schons_.pdf: 2733792 bytes, checksum: 704c4ce2631dfdbe7af1fc3c3e324404 (MD5) / Made available in DSpace on 2017-05-25T11:43:56Z (GMT). No. of bitstreams: 1 Alisson Schons_.pdf: 2733792 bytes, checksum: 704c4ce2631dfdbe7af1fc3c3e324404 (MD5) Previous issue date: 2016-02-24 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / UNISINOS - Universidade do Vale do Rio dos Sinos / O lixiviado de aterro sanitário tem se caracterizado pela alta concentração de matéria orgânica recalcitrante, nitrogênio amoniacal e compostos tóxicos. Compostos orgânicos recalcitrantes são raramente removidos por processos tradicionais de tratamentos de efluentes, o que dificulta o atendimento aos padrões de lançamento de efluentes. Da mesma forma, o descarte do esgoto doméstico gerado pelas comunidades precisa também de tratamentos prévios para não impactar o meio ambiente. Devido às características do esgoto doméstico, com baixas concentrações de matéria orgânica carbonácea e cor em relação ao lixiviado, vem permitindo que o tratamento combinado desses efluentes seja uma alternativa viável. Diante desse quadro, este trabalho visou à avaliação do tratamento combinado de esgoto doméstico da estação de tratamento de efluentes (ETE) da Unisinos e lixiviado bruto do aterro sanitário de São Leopoldo, utilizando ozônio (O3) como agente oxidante. Os efluentes foram tratados na unidade experimental composta por um reservatório com capacidade de até 500L e um reator cilíndrico de PVC com 250 mm de diâmetro e 2,20 m de altura, operando com fluxo ascencional, totalizando um volume de trabalho de 108 L e preenchido em 2/3 do seu volume total com Anel Pall de 1,5”. Realizaram-se três ensaios em bateladas, com duração de cinco horas e três ensaios com duração de duas horas, com diferentes produções de O3 de 8,9; 9,6 e 10,5 g de O3.h-1, aplicados à mistura de 2% de lixiviado de aterro sanitário (LAS) ao esgoto doméstico (2 L de LAS e 158 L de esgoto). Cada ensaio foi realizado em duplicata, sendo monitorados os seguintes parâmetros: Demanda Química de Oxigênio, Demanda Bioquímica de Oxigênio, Cor Aparente e Verdadeira, Turbidez, pH e calculada as taxas de utilização e de perda de O3. Os resultados evidenciaram que o tratamento por O3 pode ser uma alternativa de pré-tratamento de efluentes, obtendo remoções médias de DQO, DBO, CA, CV e Turbidez de até 46%, 51%, 86%, 86% e 81% respectivamente em cinco horas de ensaio e remoções médias de até 23%, 48%, 78%, 76% e 58% respectivamente em duas horas de ensaio. As maiores taxas de remoções foram alcançadas nos ensaios com maiores vazões de O2 e produções de O3 e nas duas primeiras horas de ensaio. Só foi possível o atendimento aos padrões de lançamentos de efluentes exigidos pela legislação vigente, nos ensaios com duração de cinco horas e com a maior produção de O3 e vazão de O2. O sistema de tratamento também contribuiu para uma melhora na biodegradabilidade do efluente se analisada a relação DBO/DQO e cor. Quanto as taxas de utilização e de perda de O3, verificou-se que a maior quantidade consumida de O3, ocorreu para os parâmetros indicativos de matéria orgânica e para os ensaios com a menor produção de O3. / Landfill leachate has been characterized by the high concentration of recalcitrant organic matter, ammoniacal nitrogen and toxic compounds. Recalcitrant organic compounds are rarely removed by traditional effluent treatment processes. In addition, the treatment of the leachate is colloquial to meet the discharge standards of the effluent. Likewise, the domestic sewage disposal generated by the communities also needs previous treatments to avoid impacts on the environment. Due to the characteristics of domestic sewage, with low concentrations of organic carbon in relation to the leachate, it has allowed the combined treatment of these effluents to be a viable alternative. In view of this situation, this work had the objective of evaluating the combined treatment of domestic sewage of (ETP) and the raw leachate of the San Leopoldo landfill using ozone (O3) as an oxidizing agent. Three batch trials were carried out with a scheduled duration of five hours and three trials lasting two hours, with different yields of O3 of 8.9, 9.6 and 10.5 g of O3.h-1, applied to the mixture Of 2% of landfill leachate) For domestic sewage (2L of LAS and 158L of sewage). Each assay was performed in duplicate and the following parameters were monitored: Oxygen Chemical Demand, Biochemical Oxygen Demand, Apparent and True Color, Turbidity, pH and calculated O3 utilization and loss rates. The results showed that the treatment with O3 can be an excellent alternative of pretreatment of effluents, obtaining average removals of COD, BOD, CA, CV and Turbidity of up to 46%, 51%, 86%, 86% and 81 % Respectively. Average test and removal hours of up to 23%, 48%, 78%, 76% and 58%, respectively, in two hours of testing. The highest removal rates were obtained in the tests with higher flows of O2 and yields of O3 and in the first two hours of the test. It was only possible to meet the effluent release standards required by current legislation, in trials with a duration of five hours and with the highest production of O3 and O2. The treatment system also contributed to an improvement in the biodegradability of the effluent if the BOD/COD ratio was analyzed. As for the rates of use and loss of O3, it was verified that the highest amount of O3 occurred for the parameters indicative of organic matter and for the tests with lower production of O3. The higher the O3 production, the higher the O3 loss and the greater oxidant loss may have been due to volatilization in the effluent accumulation reservoir, since there was no gas loss due to Off-gas and the method used Not Detected The residual ozone.
43

Tratamento de efluentes aquosos contendo clorofenóis por meio de processo oxidativo avançado foto-Fenton. / Treatment of wastewater containing chlorophenols by photo-Fenton advanced oxidation process.

Juárez Cardeña, Úrsula María 06 March 2009 (has links)
Nos últimos anos, os processos oxidativos avançados (POAs) têm emergido como métodos potencialmente poderosos para transformar poluentes orgânicos recalcitrantes em substâncias menos tóxicas. O presente trabalho visa estudar a degradação de clorofenóis 2,4-diclorofenol (2,4-DCF) e pentaclorofenol (PCF) em solução aquosa por meio do processo foto-Fenton. Os experimentos foram realizados em um reator fotoquímico, em regime batelada, com recirculação e admissão contínua de peróxido de hidrogênio. Os efeitos das concentrações iniciais de clorofenóis, H2O2 e Fe(II), bem como, da potência da lâmpada de vapor de mercúrio, foram estudados a partir de um planejamento experimental Doehlert em multiplos níveis e analisados segundo a metodologia de superfícies de respostas. A foto-oxidação foi monitorada por medidas da concentração de carbono orgânico total (TOC) e do espectro de absorção da solução ao longo do tempo e, em alguns casos, medidas de toxicidade por meio de bioensaios com Artemia sp. Os resultados dos experimentos realizados com 2,4-DCF evidenciaram degradação gradativa, com remoções de TOC superiores a 99%, após 1 hora de tratamento, além de remoção de toxicidade, mesmo para altas concentrações iniciais do poluente (até ca. 415 mgC L-1). Nos experimentos realizados com PCF observouse decaimento inicial de TOC bastante rápido (15 minutos), o que sugere que a degradação dos clorofenóis torna-se mais rápida com o aumento do número de átomos de cloro ligados ao anel aromático. Foi removida mais da metade do TOC inicial por volta de 30 minutos de reação, obtendo-se remoções de até 90,8% ao final do tratamento. Por outro lado, comparado ao 2,4-DCF, no caso do PCF observou-se redução acentuada da taxa de remoção de TOC após esse tempo, o que pode ser explicado a partir da maior concentração de íons cloreto em solução, da formação de complexo estável desses íons com Fe(III) e de espécies geradas a partir de reações envolvendo esse complexo. No conjunto, os resultados comprovam a viabilidade do processo foto-Fenton para remediação de efluentes aquosos contendo clorofenóis. / In recent years, advanced oxidation processes (AOP) have emerged as potentially powerful methods to transforming organic pollutants into harmless substances. The present work aims to study the degradation of chlorophenols (2,4-dichlorophenol and pentachlorophenol) in aqueous solution by the photo-Fenton process. The experiments were conducted in a batch recycle photochemical reactor with continuous feed of hydrogen peroxide solution. The effects of the initial concentrations of chlorophenols, H2O2, and Fe(II), as well as of the electric power of mercury vapor lamp, were studied by means of a Doehlert multivariate experimental design at multiple levels. Experimental results were analyzed according to the response surface methodology. In order to characterize the degradation of the pollutant, time-measurements of the total organic carbon concentration (TOC) as well as the absorbance spectra of the solution, were carried out. In some cases toxicity bioassays were carried out with Artemia sp. The results obtained from experiments with 2,4-dichlorophenol showed a gradual degradation, with more than 99% of TOC removals after 1 hour of treatment, along with toxicity removal, even for high initial pollutant concentrations (ca. 415 mgC L-1). In the case of pentachlorophenol, a fast initial TOC decrease (around 15 minutes) was observed, suggesting that chlorophenols degradation becomes faster with the increment of chloro atoms number bounded to the aromatic ring. More than a half of the initial TOC was removed around 30 minutes of reaction, rising 90.8% of TOC removal at the end of the treatment. In the other hand, comparing to 2,4-DCF, for PCF a marked reduction of the maximum rate of TOC removal after that time. This can be explained by higher concentrations of chloride ions in the solution, for the formation of stable complexes with Fe(III) ion and resulting species in reaction involving such complexes. As a whole, the results confirm the effectiveness of the photo-Fenton process for the remediation of aqueous solutions containing chlorophenols.
44

Sustainable development of an integrated solid waste and wastewater treatment

Wong, Ling Say January 2012 (has links)
This PhD thesis investigated solid and liquid waste treatment systems for Sureclean, a waste Management company based in the North of Scotland. Sureclean receives a diverse range of waste streams and the increasing need for sustainable development as well as stringent environmental legislation motivated this research to develop an integrated waste treatment system. Waste characterisation was conducted using a range of analytical instrumentation to identify the TPH, COD, heavy metals content, TOC, and particle size of Sureclean waste streams. From there, four treatment systems were investigated utilising Sureclean waste streams: mechanical separation, chemical treatment, electro-coagulation and the advanced oxidation process. Laboratory and field trials were conducted using these different treatment techniques and the analysis was performed to verify the treatment results. The result of these trials led to the development of four modular waste treatment units, that form the outcome of this research: the Sureclean Water Treatment System (SWTS), a filtration based mechanical separation system was shown to reduce the TSS, BOD and TOC content of an oily wastewater; the Sureclean Sludge Separation System (SSSTS), a chemical-enhanced filtration based system was demonstrated to reduce 52.6 % of the sewage sludge volume; the Sureclean Electro-coagulation Water Treatment System (SEWTS), a system that agglomerates colloid particles and demulsifies oil removed 99.9 % of TPH from Sureclean interceptor effluent; and the Sureclean Advanced Water Treatment System (SAWTS), an advanced oxidation process which was demonstrated to reduce the TPH of a contaminated groundwater collected from an ex-gas work. The treated effluent could be discharged to Sureclean interceptor. The four treatment units developed in this research expanded Sureclean waste treatment capabilities and an integrated system was developed to treat different waste streams and to improve the treatment efficiency thus increasing the revenue and future waste stream options for Sureclean.
45

Degradação de poluentes emergentes por processos oxidativos avançados (O3, O3/UV, O3/Fe2+, O3/UV/Fe2+) visando o tratamento de efluentes hospitalares / Degradation of emergent pollutants by advanced oxidative processes (O3, O3/UV, O3/Fe2+, O3/UV/Fe2+) aiming at hospital wastewater treatment

Souza, Fernanda Siqueira January 2016 (has links)
Compostos farmacêuticos são detectados em diversas matrizes ambientais. Estes compostos, quando não eliminados por técnicas avançadas de tratamento, contribuem para impactos ambientais negativos. Especificamente, efluentes hospitalares apresentam altas concentrações destes compostos principalmente pela excreção por pacientes. Neste contexto, o presente trabalho visa contribuir com a pesquisa científica em relação a efluentes hospitalares no Brasil, propondo alternativas de tratamento com ozônio para a remoção de fármacos. Para atingir o objetivo proposto, foi realizado um diagnóstico em um hospital visando identificar o consumo das principais classes farmacêuticas. A partir deste estudo, desenvolveu-se um planejamento de experimentos para avaliar os parâmetros mais adequados do processo de ozonização para a remoção de cafeína (CAF), amoxicilina (AMX) e ampicilina (AMP) em soluções aquosas. Foram avaliados experimentalmente os processos O3, O3/UV, O3/Fe2+, O3/UV/Fe2+. Investigou-se a influência da concentração inicial de fármaco, do pH, da potência de luz UV aplicada e da concentração inicial de Fe2+ utilizado como catalisador homogêneo. A variável de resposta foi a eficiência de mineralização. Os parâmetros obtidos pelo planejamento experimental foram aplicados para o Atenolol (ATE) e para soluções aquosas contendo a mistura de todos os compostos analisados (CAF, AMX, AMP e ATE). Um estudo cinético para determinação das constantes de reação foi realizado para a cafeína e atenolol. Para avaliar o tratamento com efluente hospitalar, uma caracterização (detecção de compostos farmacêuticos e parâmetros físico-químicos e toxicológicos) foi realizada antes e após o processo que apresentou a melhor eficiência de mineralização. Com o objetivo de extrapolar os estudos realizados e avaliar outros poluentes emergentes, além dos compostos farmacêuticos, realizaram-se experimentos com 90 compostos como drogas de abuso, hormônios e produtos de higiene pessoal que também podem estar presentes em efluentes hospitalares, avaliando a influência do pH e da dosagem de ozônio aplicada. Como principais resultados, os antibióticos e cardiovasculares foram as classes farmacêuticas mais consumidas no hospital. Pelo planejamento de experimentos, observou-se que todos os compostos avaliados foram rapidamente degradados (100% em menos de 15min) e as melhores eficiências de mineralização atingiram 70,8%, 60,4% e 63,6% para CAF, AMX e AMP, respectivamente. O sistema O3/UV/Fe2+ obteve a melhor eficiência de mineralização para o ATE (67,9%) e para a mistura dos compostos (69,5%). O estudo cinético possibilitou o cálculo das constantes cinéticas: kO3 =697,46 M-1 s-1 e kOH = 6,41x109 M-1 s-1 para a cafeína; e kO3 =146,56 M-1 s-1 e kOH = 15,29x109 M-1 s-1 para o atenolol. A eficiência de mineralização para os experimentos com efluente hospitalar atingiu 54,7% para o sistema O3/UV, sendo eficiente para a completa eliminação de diversos compostos farmacêuticos e remoção da toxicidade. Em relação à remoção dos 90 poluentes emergentes, observou-se que 53,3% dos compostos foram completamente degradados utilizando uma razão mMO3/mMC=0,3 em pH neutro. Os resultados encontrados indicam que o presente trabalho contribui para o avanço da pesquisa sobre efluentes hospitalares, pois apresenta uma alternativa de tratamento eficiente para a completa remoção de diversos compostos farmacêuticos, minimizando o impacto negativo destes no meio ambiente. / Pharmaceutical compounds (PhCs) are detected in various environmental matrices. These compounds, whether not eliminated by advanced treatment techniques, contribute to bacterial resistance and negative environmental impacts on water resource. Specifically, hospital wastewaster exhibit high concentrations of these compounds mainly by the excretion by patients. In this context, this paper aims to contribute to scientific research regarding hospital wastewater in Brazil, proposing treatment alternatives by ozone to remove PhCs. To achieve this purpose, it conducted a diagnosis in a hospital to identify the consumption of major pharmaceutical classes. With this result, it developed an experimental design to evaluate the most appropriate parameters of the ozonation process for the removal of caffeine (CAF), amoxicillin (AMX) and ampicillin (AMP) in aqueous solutions. This study evaluated the following processes experimentally: O3, O3/UV, O3/Fe2+ O3/UV/Fe2+. The influence of ozone dose, initial PhCs concentration, pH, power UV light applied and Fe2+ initial concentration used as homogeneous catalyst were investigated. Mineralization efficiency was the response variable. Parameters obtained by the experimental design were applied for Atenolol (ATE) and aqueous solutions containing the mixture of all compounds analyzed (CAF, AMX, AMP and ATE). A kinetic study for the determination of reaction constants was carried out for caffeine and atenolol. To evaluate the hospital wastewater treatment, a characterization (detection of pharmaceutical compounds and physico-chemical and toxicological parameters) was performed before and after the process that showed the best mineralization efficiency. In order to extrapolate the studies and evaluate other emergent pollutants, in addition to pharmaceutical compounds, were conducted experiments with 90 compounds such as illicit drugs, hormones and personal care products, which also may be present in hospital wastewater, evaluating the influence of pH and ozone dosage. Main results showed that antibiotics and cardiovascular were the most consumed pharmaceutical classes in the hospital. For the design of experiments, it was observed that all the evaluated compounds were rapidly degraded (100% in less than 15 minutes) and the best mineralization efficiency reached 70.8%, 60.4% and 63.6% for CAF and AMX AMP, respectively. The system O3/UV/Fe2+ obtained the best mineralization efficiency for ATE (67.9%) and mixture of compounds (69.5%). The kinetic study allowed the determination of the kinetic constants: kO3 = 697.46 M-1 s-1 and kOH = 6.41x109 M-1 s-1 for caffeine; and kO3 = 146.56 M-1 s-1 and kOH = 15.29x109 M-1 s-1 for atenolol. Mineralization efficiency for hospital wastewater experiments reached 54.7% by the system O3/UV, being efficient for complete elimination of various PhCs and removal of toxicity. Regarding the removal of 90 emergent pollutants, it was observed that 53.3% of the compounds were completely degraded using a ratio mMO3/MMC = 0.3 at neutral pH. The results indicated that this work contributes to the advance of research on hospital wastewater, because it presents an effective alternative treatment for complete removal of various pharmaceutical compounds, minimizing the negative impact on the environment.
46

Estudo da degradação de fenol e seus intermediários pelo processo UV/H2O2. / Study of the degradation of phenol and its intermediates by UV/H2O2 process.

Pâmela Coelho Tambani 16 June 2011 (has links)
No processo UV/H2O2, oxidar o substrato a CO2 e água resulta em um elevado consumo de H2O2. Então, esse processo tem sido proposto como um pré-tratamento para reduzir a toxicidade a níveis seguros para o tratamento biológico posterior. Por essa razão, é necessário estudar o progresso da reação, pois a toxicidade de alguns intermediários formados durante a oxidação pode ser mais elevada que a do composto inicial. Neste trabalho, os experimentos foram realizados em um reator tubular fotoquímico, contendo em seu eixo uma lâmpada de vapor de mercúrio de baixa pressão, conectado a um tanque de recirculação. O processo UV/H 2O2 é aplicado no tratamento de água contendo fenol (50500mg C.L-1). Os resultados demonstraram que o principal produto da oxidação primária é o catecol, indicando que a hidroxilação ocorre predominantemente na posição orto. A abertura do anel aromático leva à formação de ácidos orgânicos, o que explica a diminuição do pH durante a reação. Foram identificados os seguintes ácidos: fórmico, oxálico, maleico e malônico. Na etapa seguinte desse trabalho, dois modelos cinéticos foram desenvolvidos. Os modelos foram baseados nas reações químicas e fotoquímicas iniciadas pelos radicais hidroxila gerados pela fotólise do peróxido de hidrogênio. Foram utilizados os valores encontrados na literatura para os parâmetros fotoquímicos e constantes cinéticas das reações fotoquímicas. Os resultados experimentais foram utilizados para estimar as constantes cinéticas das reações que envolvem os compostos aromáticos. No primeiro modelo foram contempladas todas as reações fotoquímicas envolvidas e, no segundo, apenas as consideradas mais significantes. Os resultados das simulações considerando os parâmetros ajustados mostraram uma melhor concordância com os dados experimentais para o primeiro modelo. As constantes cinéticas deste modelo para as reações nas quais o fenol é oxidado a catecol (k14) e hidroquinona (k15) foram 2,60x108L.mol-1.s-1 e 1,03x108L.mol-1.s-1, respectivamente. As constantes cinéticas para a oxidação do catecol (k17) e hidroquinona (k18) encontradas foram 1,41x108L.mol-1.s-1 e 2,02x108L.mol-1.s-1, respectivamente. Também foi observada elevada correlação entre as constantes k14 e k17 e entre k15 e k18. / In the UV/H2O2 process, the oxidation of the substrate to CO2 and water results in high H2O2 consumption. Due to this fact the process has been proposed as a pretreatment to reduce toxicity to safe levels prior to biological treatment. Thus, it is necessary to study the reaction progress because some intermediate compounds may be more toxic than the initial compound. In the present study experiments were carried out in a lab-scale tubular photochemical reactor with a low-pressure mercury vapor lamp placed in its axis, connected to a recirculation tank. The UV/H2O2 process was applied to the degradation of an aqueous solution containing phenol as a model pollutant (concentration range: 50-500mg.L-1). The experimental results indicated that orto-hydroxylation (catechol formation) was predominant. The cleavage of the aromatic ring resulted in the production of organic acids, which caused the pH decrease over the reaction time. The following acids were detected: formic, oxalic, maleic and malonic. The experimental results were used to estimate kinetic rate constants for the reactions involving aromatic compounds according to two kinetic models based on chemical and photochemical reactions, initiated by hydrogen peroxide photolysis to produce hydroxyl radical. Numerical values of chemical reaction rate constants and photochemical parameters were taken from literature. The first model considered all photochemical while the second model considered the most significant ones. The parameter fitting results showed better agreement with experimental values based on the first model. The resulting values for the rate constants according to this model were as follows: 2.60x108L.mol-1.s-1 for phenol oxidation to catechol, and 1.03x108L.mol-1.s-1 for phenol oxidation to hydroquinone by hydrogen peroxide. The reaction rate constants for the oxidation of catechol, and hydroquinone by hydrogen peroxide are 1.41x108L.mol-1.s-1 and 2.01x108L.mol-1.s-1, respectively. A high correlation was observed between constants k14 and k17, and between k15 and k18.
47

Aplicação do método estatístico de Taguchi no estudo dos Processos Oxidativos Avançados (Fe+2 / H2O2 / O3 / UV) no pré-tratamento de efluentes fenólicos / Application of Taguchi statistical methods in the study of Advanced Oxidation Processes (Fe2+/H2O2/O3/UV) in the pre- treatment in phenolic wastewater

Ana Paula Barbosa Rodrigues de Freitas 04 May 2012 (has links)
O efluente fenólico em estudo apresenta a relação DBO5/DQO (Demanda Bioquímica de Oxigênio/ Demanda Química de Oxigênio) igual a 0,15, ou seja caracteriza-se por ser um efluente não biodegradável. No tratamento inicial do efluente utilizou-se ozônio, na presença do sal de ferro II proveniente da solução de sulfato ferroso heptaidratado 0,82 mol. L-1 e do peróxido de hidrogênio , que possui a finalidade catalítica na formação dos radicais hidroxilas, com alto poder de oxidação da matéria orgânica. Nesta etapa foi estudado a união dos processos oxidativos O3/UV e Foto-Fenton, Foram tratados 3 L do efluente fenólico in natura em um reator fotocatalítico com lâmpada ultravioleta. Em todos os experimentos o pH e a temperatura do meio reacional foram controlados. Os experimentos foram executados segundo um planejamento de Taguchi L16, no qual a variável entrada de maior importância para a degradação da matéria orgânica foi o peróxido de hidrogênio. As variáveis respostas analisadas foram a concentração do Carbono Orgânico Total, Demanda Química de Oxigênio e Fenóis Totais. No planejamento de Taguchi L16 foram selecionadas as variáveis significativas para o processo de degradação do efluente fenólico, a fim de serem otimizadas através do Método de Superfície de Resposta (MSR Foto-Fenton e O3/UV). O método de otimização MSR Foto-Fenton foi eficiente na degradação do composto fenólico, sendo assim a melhor condição experimental da planilha de otimização foi a de número 10 e corresponde a uma redução de COT= 54,68%, DQO=78,73% e Fenois Totais= 98,1%. Os parâmetros controlados do processo para essa condição foram: pH=3, temperatura de 30 ºC, potência ultravioleta de 28 W e reagente Fenton (H2O2= 48,3g e Fe+2 =5,95g), que corresponde a relação mássica H2O2 /Fe+2 igual a 8. / The phenolic effluent in this study has the rate DBO5/DQO (Biochemical Oxygen Demand / Biochemical Oxygen Demand) equal to 0.15, which is characterized by an effluent to be non-biodegradable. In the initial treatment of phenol was used ozone in the presence of iron salt II from the solution of ferrous sulfate heptahydrate 0.82 mol. L-1 and hydrogen peroxide, which has the purpose in the catalytic formation of hydroxyl radicals with high oxidation power of organic matter. In this stage, was studied the union of the oxidative process O3/UV and Photo-Fenton. The effluent was treated about 3 L about in a photocatalytic reactor with UV lamp. In all experiments, the pH and temperature of the reaction medium were control. The experiments are being carried out to a Taguchi L16 design, in which the input variable of greatest importance to the degradation of organic matter was hydrogen peroxide. The response variable analyzed was given by the concentration of Total Organic Carbon (TOC) and Chemical Oxygen Demand (COD) and Total Phenols (FT). In planning Taguchi L16 significant variables were selected for the degradation process of phenolic wastewater in with purpose of to be optimized by Response Surface Method (RSM Photo-Fenton and O3/UV). The optimization method was efficient photo-Fenton degradation of phenolic compound, so the best experimental condition spreadsheet optimization was the number 10 and corresponds to a reduction of TOC = 54.68%, COD = 78,73% and Total Phenols= 98.1%. The controlled process parameters for this condition were: pH = 3, temperature of 30 ° C, power of 28 W ultraviolet and Fenton reagent (H2O2= 48,3g and Fe+2 = 5,95g), corresponding to mass ratio H2O2 / Fe +2 = 8.
48

Combinaçäo de adsorçäo por carväo ativado com processo oxidativo avançado (POA) para tratamento de efluentes contendo fenol. / Combination of adsorption by activated carbon with advanced oxidation process (AOP) for the treatment of wastewater containing phenol.

Muranaka, CÍnthia Tiemi 25 June 2010 (has links)
O processo de adsorção por carvão ativado é uma técnica muito aplicada para tratamento de efluentes. Porém o tratamento que envolve adsorção não é um sistema completo, pois há a necessidade da destruição dos compostos que foram imobilizados na superfície do carvão. Frente a esse problema, métodos alternativos de regeneração de carvão ativado são investigados. Os processos Fenton e foto-Fenton são considerados tecnologias promissoras de tratamento de efluentes, e foram testados para regenerar o carvão ativado. Este trabalho objetiva estudar a adsorção de fenol em carvões ativados (CAs) e a consecutiva regeneração in-situ do carvão pela oxidação de (foto-) Fenton. Duas operações diferentes foram realizadas: 1) sistema de batelada, a fim de investigar a influência das concentrações de Fe2+ e H2O2; 2) adsorção contínua em leito fixo, seguido de circulação em batelada dos reagentes de Fenton pelo leito de CA saturado, para examinar a eficiência do processo real. Foram estudados dois tipos de carvão ativado: CA L27 (meso e microporoso) e CA S23 (somente microporoso). No reator de batelada as melhores condições encontradas para a mineralização do poluente no sistema Fenton homogêneo não são as melhores para a regeneração do CA: foi observada uma redução contínua da capacidade de adsorção do L27 após 3 oxidações, devido à redução tanto da massa do CA quanto da área superficial. Uma maior concentração de Fe2+ e menor concentração de H2O2 (2 vezes a estequiometria) levou a uma recuperação de 50% da capacidade de adsorção inicial em pelo menos 4 ciclos consecutivos para o L27, enquanto que cerca de 20% para o S23. No processo consecutivo de adsorção contínua/oxidação de Fenton em batelada, a eficiência de regeneração atinge de 30% a 40% para o L27 após dois ciclos independente da concentração da alimentação e menos de 10% para o S23. O processo foto-Fenton realizado para o L27 levou à quase completa mineralização e aumentou a recuperação da capacidade de adsorção do CA (56% após dois ciclos). / The adsorption process by active carbon is a technique applied extensively for wastewater treatment. However the tertiary treatment involving adsorption is not a complete system, since there is a need of destruction of the compounds that were immobilized on the carbon surface. In face of this problem, some alternative regeneration methods of active carbon are investigated. Fenton and photo-Fenton processes have been considered promising technologies for wastewater treatment and have been tested to regenerate the AC. The purposes of this study are the adsorption of phenol on activated carbons (ACs) and the consecutive in-situ regeneration of carbon by (photo-) Fenton oxidation. Two different operations have been carried out: 1) batch procedure in order to investigate the influence of Fe2+ and H2O2 concentrations; 2) continuous fixed bed adsorption, followed by a batch circulation of the Fentons reagent through the saturated AC bed, to examine the efficiency of the real process. Two different activated carbons have been also studied: a both micro- and mesoporous AC (L27) and an only microporous one (S23). In the batch reactor the best conditions found for pollutant mineralization in the homogeneous Fenton system are not the best for AC regeneration: a continuous reduction of adsorption capacity of L27 is observed after 3 oxidations, due to the decrease of both AC weight and surface area. Higher concentration of Fe2+ and lower concentration of H2O2 (2 times the stoechiometry) lead to a 50% recovery of the initial adsorption capacity during at least 4 consecutive cycles for L27, while about 20% for S23. In the consecutive continuous adsorption/batch Fenton oxidation process, the regeneration efficiency reaches 30% to 40% for L27 after two cycles whatever the feed concentration and less than 10% for S23. A photo- Fenton test performed on L27 shows almost complete mineralization (contrary to dark Fenton) and further improves recovery of AC adsorption capacity although not complete (56% after two cycles).
49

Degradação de fármacos em meio aquoso por meio de fotólise e peroxidação fotoassistida. / Degradation of pharmaceuticals compounds in aqueous medium by photolysis and photoassisted peroxidation.

Katsumata, Caroline Pereira 28 August 2014 (has links)
Estudou-se a degradação dos fármacos acetaminofeno (ACT), atenolol (ATL), bezafibrato (BZF), diclofenaco (DIC) e ibuprofeno (IBU) em solução aquosa através de fotólise e peroxidação fotoassistida. As soluções foram caracterizadas antes e após os processos de fotólise e UV/H&#8322O&#8322 quanto à degradação dos fármacos e à remoção de carbono orgânico total. Também foi avaliada a degradação por fotólise dos fármacos em uma matriz real (efluente de estação de tratamento de esgoto, ETE). Os experimentos foram realizados em um reator anular com lâmpada de vapor de mercúrio de baixa pressão de 36 ou 75 W e concentrações iniciais de 5 ou 20 mg L&#8315&#185 de cada fármaco, em mistura e individualmente, no caso dos estudos de fotólise UV. Os resultados mostraram absorção de radiação UV (254 nm) pelo ACT superior à dos demais fármacos (&#8364=8990 L mol&#8315&#185 cm&#8315&#185), e comparativamente inferior para o ATL e IBU (&#8364=725 e 1080 L mol&#8315&#185 cm&#8315&#185, respectivamente). Não houve degradação por hidrólise após 24h em qualquer pH. O DIC e o BZF degradaram-se mais rapidamente, independentemente do processo fotoassistido. As concentrações de DIC nos experimentos realizados com [DIC]0=5 mg L&#8315&#185 ficaram abaixo do limite de detecção após 20 minutos de irradiação. Na presença de H H&#8322O&#8322 as concentrações dos contaminantes ficaram abaixo do limite de detecção após 50 minutes para concentrações iniciais de 20 mg L&#8315&#185. Os resultados dos ensaios de toxicidade nos experimentos realizados com a mistura de fármacos mostraram valores de CE50 inferiores aos valores obtidos nos experimentos com a solução dos fármacos individuais. Os valores de TOC apresentaram redução de até 13% ao final de 120 minutos, o que comprova a persistência dos produtos de degradação. A degradação por fotólise UV do ATL e do ACT ocorreu mesmo em efluente de ETE, sendo a eficiência desse processo semelhante à obtida usando-se água como matriz. Esses resultados são úteis para compreensão da remediação de águas e efluentes contendo esses contaminantes emergentes por meio de processos foto-oxidativos. / This work aimed at studying the degradation of the following pharmaceutical compounds in aqueous solution by means of photolysis and photoassisted peroxidation: acetaminophen (ACT), atenolol (ATL), bezafibrate (BZF), diclofenac (DIC), and ibuprofen (IBU). Solutions were characterized before and after photolysis and UV/H2O2 processes regarding drug degradation and total organic carbon removal. In addition, the photolysis of the pharmaceutical compounds was investigated in a real wastewater matrix (effluent from a sewage treatment plant, STP). The experiments were carried out in an annular photochemical reactor equipped with a low pressure mercury lamp (36 or 75 W) and initial solution concentrations of 5 and 20 mg L-1 of each drug, for the mixture and individual compounds, in the case of UV photolysis studies. The results revealed higher absorption of UV radiation (254 nm) by ACT than that shown by the other pharmaceutical compounds (=8990 L mol-1 cm-1), and comparatively lower for ATL and IBU (=725 and 1080 L mol-1 cm-1, respectively). No hydrolysis was observed after 24 hours at any pH. The degradation of DIC and BZF was faster, regardless the photoassisted process. DIC concentrations in the experiments carried out with [DIC]0=5 mg L-1 were below the detection limit after 20 minutes of irradiation. In the presence of H2O2, contaminant concentrations were below the detection limit after 50 minutes of irradiation for initial concentrations of 20 mg L-1. The results of the toxicity assays for the experiments carried out with the mixture of pharmaceutical compounds showed CE50 values lower than those obtained with the compounds individually. TOC removals up to 13% after 120 minutes were obtained, therefore confirming the formation of persistent degradation products. In the case of ATL and ACT, UV degradation occurred even in STP wastewater and the efficiency of the process was similar to that obtained with pure water. The results obtained in this study are useful to understand the treatment of water and wastewater contaminated with this class of emerging pollutants by means of photo-oxidative process.
50

Treatment of Reverse Osmosis Concentrates from Recycled Water

Arseto Yekti Bagastyo Unknown Date (has links)
Water recycling by membrane treatment is widely accepted as a leading alternative water source. This separation process creates a concentrated stream (called concentrates), containing most of the pollutants in 10%-20% of the flow; and a treated water stream. As nitrogen is a major concern, environmental regulations have become more stringent, requiring additional treatment to meet effluent standards. Other concerns include organic contaminants and potential production of halogenated organics if disinfection of the reject was applied. One option to address the problem of dissolved organic nitrogen and carbon is advanced oxidation. This oxidation could lead to degradation of refractory organic materials, which are poorly removed in conventional treatment. This project aims to evaluate treatment extent and cost of alternatives for organic (particularly nitrogen) removal in reject water addressing the following research gaps: (i) identifying the key organic pollutants present in the concentrated stream, (ii) the effectiveness and optimisation of coagulation, ion exchange and advanced oxidation; (iii) apparent cost of the different treatment methods. The untreated reverse osmosis concentrates were collected from two treatment plants:- Luggage Point, and Bundamba, both near Brisbane, Queensland, Australia. The first contains more colourful of organics than the second plant. Stirred cell fractionation with ultrafiltration membranes was used to characterise the removed key pollutants, as it offers better accuracy and reproducibility compared to centrifugation fractionation. Fluorescence spectral was used to monitor and identify specific organic compounds. The largest fraction was smaller sized <1kDa. This is probably small humic substances and fulvic acids, as indicated by Excitation Emission Matrix (EEM) analysis. A smaller portion of soluble microbial products (SMPs) also contributes to the concentrates. Bundamba contains large non coloured organics including organic nitrogen with elevated ammonia-N. In contrast, Luggage Point has higher colour, inorganic carbon and conductivity with less ammonia-N. Advanced Oxidation Process (AOP) was the most effective treatment method (high removal of organics, e.g. 55% COD of initial), followed by magnetised ion exchange (MIEX) and coagulations. For UV/H2O2 AOP, the optimal operating condition 400mg.L-1 H2O2 and 3.1kWh.m-3 energy input resulted in organics removals up to 55% with complete decolourisation. The effective reduction was found in all size ranges, preferably in >1kDa. Low inorganic carbon and salinity in Bundamba may allow better overall oxidation rates. MIEX also performed better in Bundamba with organic removals up to 43% and 80% decolourisation at the optimum resin dose of 15mL.L-1. Removal was preferential in size range of >3kDa, with more proportional percentage for decolourisation. Similarly, ferric coagulation removed a wider size range of organics. Further, ferric achieved better organic removal in Luggage Point with up to 49%. At the same molar dose (1.5mM), ferric is superior to alum, especially in Bundamba where there were less hydrophobic compounds according to EEM. Alum is poor for treatment of high organics with less coloured water. MIEX with an operational cost (chemicals and power only) of $0.14-$0.20.m-3 treated water seemed to be the most effective treatment overall. The resin achieved better results with a slightly higher cost than coagulation, and had a lower environmental impact due to reduced sludge production. AOP offers better treatment, but at a higher cost ($0.47.m-3 treated). Combined alternatives may benefit the removal effectiveness. Furthermore, more specific identification of contaminants should be investigated separately to choose appropriate treatment for priority chemicals. Another issue is further investigation of costing, including capital, and full environmental impact of treatment.

Page generated in 0.122 seconds