Spelling suggestions: "subject:"affinitätschromatographie"" "subject:"affinitätchromatographie""
1 |
Matrix gestützte Polymernetzwerke für die Anwendung in der konvektiven präparativen Chromatographie / Matrix based polymer networks for the use in convective preparative chromatographyLey, Adrian 08 January 2019 (has links)
No description available.
|
2 |
Immobilisierte Ribonucleoside - Ihre Synthese und BioaffinitätRosemeyer, Helmut 17 December 2015 (has links)
A novel method for the immobilization of ribonucleosides to polysaccharides, namely to agarose, is presented, and the immobilized nucleosides are used for the purification of nucleoside-converting enzymes, such as adenosine deaminase, guanase OMP-decarboxylase and xanthine oxidase.
|
3 |
Untersuchungen zur molekularen Ursache der Multiplen Sulfatase-Defizienz: Reinigung, Funktions- und Strukturanalyse von varianten Proteinen des Formylglycin-generierenden Enzyms / The molecular cause of multiple sulfatase deficiency: cleaning, functional and structural analysis of variant proteins of formylglycine-generating enzymeMühlhausen, Helene 14 January 2015 (has links)
No description available.
|
4 |
Zur Struktur und Funktion regulatorischer Elemente des cbb-Regulons in Ralstonia eutropha / Structure and function of regulatory elements of the cbb regulon in Ralstonia eutrophaJeffke, Thomas 31 January 2001 (has links)
No description available.
|
5 |
Entwicklung immunchemischer Methoden zur Spurenanalytik der Sprengstoffe Nitropenta und TrinitrotoluolHesse, Almut 04 May 2017 (has links)
Der Sprengstoff PETN ist äußerst schwer zu detektieren. Ein verbesserter anti-PETN-Antikörper wurde durch Anwendung des Bioisosterie-Konzepts entwickelt. Diese polyklonalen IgGs sind sehr selektiv und sensitiv. Die Nachweisgrenze des ELISAs beträgt 0,15 µg/L. Der Messbereich des Immunoassays liegt zwischen 1 und 1000 µg/L. Die Antikörper sind recht pH-stabil als auch robust gegen Lösungsmittelzusätze. Für die Umweltanalytik von TNT wurde eine HPLC-kompatible Affinitätssäule mit porösem Glas als Trägermaterial hergestellt. Um die anti-TNT-Antikörper selektiv aus den TNT-Seren zu isolieren, wurde eine Trennung an einer Dinitrophenyl-Affinitätssäule durchgeführt. Zur Optimierung der Kopplungsmethode wurden orangefarbene Dabsyl-Proteine synthetisiert und auf der Oberfläche gebunden. Die Färbung wurde als Indikator für die Ligandendichte verwendet. Wegen der hohen Affinitätskonstanten der anti-TNT-IgGs lässt sich TNT nicht reversibel von der TNT-Affinitätssäule eluieren. Daher wurde eine neuartige Elutionsmethode entwickelt, die thermische Online-Elution. Die maximale Kapazität einer TNT- Affinitätssäule betrug 650 ng TNT bzw. 10 µg/mL Säulenvolumen. Um die Ligandendichte der TNT-Affinitätssäulen zu bestimmen, wurde ein neues Verfahren entwickelt, da die spektroskopischen Proteinbestimmungsmethoden nicht geeignet waren. Zur Proteinbestimmung wurde eine HPLC-Trennung der Aminosäuren Tyr und Phe ohne vorherige Derivatisierung entwickelt. Die Proteinhydrolysezeit wurde durch Einsatz einer Mikrowelle von 22 h auf 30 min verkürzt. Zur internen Kalibrierung wurden HTyr und FPhe verwendet. Die Nachweisgrenze bei 215 nm ist sowohl für Tyr als auch für Phe 0,05 µM (~ 10 µg/L). Dieses neue Verfahren, das als Aromatische Aminosäureanalyse (AAAA) bezeichnet werden kann, wurde zur Proteinbestimmung von homogenen Proben mit NIST-BSA validiert, wobei die Nachweisgrenze für Proteine 16 mg/L (~ 300 ng BSA) ist. Die relative Standardabweichung incl. der Hydrolysestufe beträgt 5%. / The explosive Pentaerythritol tetranitrate (PETN) is extremely difficult to detect. An improved antibody against PETN was developed by using the bioisosteric concept. These polyclonal antibodies are highly selective and sensitive. The limit of detection (LOD) of the ELISA was determined to be 0.15 µg/L. The dynamic range of the assay was found to be between 1 and 1000 µg/L. The antibodies are sufficiently pH-stable and resistant to solvent additives. An HPLC-compatible TNT-affinity column with porous glass as support material was prepared for the environmental analysis. In order to isolate the anti-TNT antibodies of the TNT sera a separation was carried out on a dinitrophenyl-affinity column. To optimize the immobilization method, orange-coloured dabsyl proteins were synthesized and bound to the surface. The colour intensity was found to be an indicator for the immobilization rate. In consequence of the high affinity constants of the anti-TNT antibodies, TNT can''t elute by a typical acidic elution step. Therefore, a novel separation approach, the thermal online-elution was developed. The maximum capacity of an affinity column was 650 ng TNT or 10 µg/mL of column volume. To quantify the immobilization rate of proteins, a new method has been developed, because the usual protein determination methods were unsuitable. Therefore an HPLC separation method of Tyr and Phe was developed without prior derivatization. Two internal standard compounds, HTyr and FPhe, were used for calibration. The LOD was estimated to be 0.05 µM (~ 10 µg/L) for Tyr and Phe at 215 nm. The protein hydrolysis time was reduced from 22 h to 30 min using microwave technique. This procedure, that was termed aromatic amino acid analysis (AAAA), has been validated for protein determination of homogeneous samples with NIST-BSA. The LOD for proteins was calculated to be below 16 mg/L (~ 300 ng BSA absolute). The relative standard deviation, including the hydrolysis step, is 5%.
|
6 |
Entwicklung von Monolithen auf Basis polyfunktioneller Glycidylether für die Anwendung in der AffinitätschromatographiePecher, Heike Susanne 28 March 2014 (has links)
Monolithische Phasen werden seit ca. 20 Jahren entwickelt und sind in den letzten Jahren eine attraktive Alternative zu etablierten mit Partikeln gefüllten Säulen geworden. Sie werden in anorganische Phasen und organische Polymermonolithe unterteilt. Monolithe bestehen aus einem einzigen, durchgehenden Stück. Charakteristisch ist das sie durchziehende Porennetzwerk, durch das der Eluent mit geringerem hydraulischen Widerstand fließen kann und das somit schnellere Flussraten ermöglicht. Polymermonolithe werden vorwiegend für die Separation großer Biomoleküle aufgrund eines durch Konvektion beschleunigten Massentransfers eingesetzt. Zudem sind sie über einen breiten pH-Wert-Bereich stabil und können direkt (in situ) im gewünschten Format polymerisiert werden. In der vorliegenden Arbeit gelang die Herstellung neuartiger epoxidbasierter Phasen nach einem von Weller et al. entwickelten Konzept, die im Affinitätsexperiment angewendet wurden. Die Herstellung erfolgte durch Autopolymerisation polyfunktioneller Glycidylether. Für die Funktionalisierung wurden nicht polymerisierte Epoxide genutzt. Als Monomere dienten TEPIC, GE 100 sowie GE 500. Die Arbeiten konzentrierten sich vor allem auf die bei Raumtemperatur durchführbaren Synthesen mit dem höher funktionellen GE 500. Die Polymerisationsbedingungen wurden hinsichtlich Porogenmischung und -anteil optimiert. Eine mit 75 Vol.-% Porogen (Dioxan/ MTBE (2:3)) hergestellte und mit rProtein A funktionalisierte Kapillarsäule (66 %, 12 µm, 7m2/g) ergab im Affinitätsexperiment eine Kapazität von 0,44 mg/mL aus Kaninchenserum isolierbarem IgG. Durch Beimischung von 60 % BDE konnte der Epoxidgehalt vervierfacht und die Porengröße auf 400 nm bei 59 % Porosität reduziert werden. Die spezifische Oberfläche wurde verdreifacht und die Kapazität präparierter Disks auf 0,90 mg/mL etwa verdoppelt. Die in dieser Arbeit entwickelten Disks können zur Isolierung von IgG aus einer komplexen Probe, wie beispielsweise Blutserum, eingesetzt werden. / Monolithic supports have been developed since 20 years and have become an attractive alternative to well-established columns packed with particles over the past years. They are classified into inorganic media and organic polymer monoliths. Monoliths consist of a single, continuous piece with an integrated characteristic porous network through which the eluent can flow with lower hydraulic resistance and which consequently offers higher flow rates. Due to an accelerated mass transfer caused by convection polymer monoliths are mainly used for separation of large biomolecules. In addition, they are stable over a wide pH range and can be polymerized directly (in situ) in the desired format. In the present work the successful preparation of new epoxide-based supports according to a concept introduced by Weller et al. as well as their application in affinity chromatography are reported. Their preparation was carried out by self-polymerization of polyfunctional glycidyl ethers and for functionalization non-polymerized epoxide groups were used. As monomers TEPIC, GE 100 and GE 500 were utilized. The work has focused especially on the polymerization of the higher functional GE 500, which can be perfomed at room temperature and was optimized in terms of both composition and amount of porogen. The extraction of IgG from rabbit serum with a capillary column (66 %, 12 µm, 7m2/g) prepared by 75 vol.-% porogen (dioxane/ MTBE (2:3)) and functionalized with rprotein A resulted in a capacity of 0,44 mg/mL. By addition of 60 % BDE the epoxide content was quadrupled and the pore size reduced to 400 nm while maintaining consistently high porosity of 59 %. The specific surface area was tripled and the capacity of prepared disks approximately doubled to 0,90 mg/mL. The disks developed in this work can be applied for the isolation of IgG from complex samples such as serum.
|
Page generated in 0.0534 seconds