Spelling suggestions: "subject:"agitação"" "subject:"gitação""
41 |
Estudo da remoção de sulfato em biorreator operado em batelada e batelada alimentada seqüenciais, contendo biomassa imobilizada e utilizando agitação mecânica e \"draft-tube\" / Study on sulfate removal in an anaerobic sequencing batch reactor containing immobilized biomass, and utilizing mechanical agitation and \"draft-tube\"Gregor Franz Friedl 26 March 2008 (has links)
Um reator anaeróbio tratando esgoto sintético de baixa concentração de matéria orgânica (500 mgDQO/L-1) e enriquecido com diferentes concentrações de sulfato (razões DQO/[SO4-2] de 1,34, 0,67 e 0,34) foi submetido à diferentes estratégias de alimentação (batelada e batelada alimentada de 3 h e de 6 h). O reator operou com capacidade de 4,0 L e tratou por ciclo de 8 h um volume de 2,0 L de esgoto sintético. Desta forma, executaram-se 9 condições diferentes que foram submetidas à análise com o objetivo de investigar a influência do tempo de alimentação e da razão DQO/[SO4-2] no desempenho do sistema. A temperatura do reator foi constante em 30 ± 1°C e a agitação mecânica foi fixada em 400 rpm. Como suporte para a imobilização da biomassa foram utilizados cubos de espuma de poliuretano. Os resultados obtidos demonstraram que a operação em batelada alimentada de 3 h com uma razão DQO/[SO4-2] de 0,34 apresentou as melhores condições para a remoção de matéria orgânica (89%). Quanto à remoção de sulfato observou-se uma estagnação neste mesmo modo de operação ao aumentar a concentração de sulfato no afluente, enquanto que na operação com alimentação em batelada alimentada de 6 h, a carga de sulfato removida (CSR) cresceu linearmente. Assim, a maior carga de sulfato removida foi registrada durante o ensaio em batelada alimentada de 6 h com uma razão DQO/[SO4-2] de 0,34, no qual foram removidos 0,55 g SO4-2(L.d). Com uma razão DQO/[SO4-2] de 1,34 e um tempo de enchimento de 6 h, o reator apresentou o melhor desempenho em termos de eficiência de remoção de sulfato (71%). Em todos os ensaios o reator apresentou estabilidade, com uma produção alta de alcalinidade a bicarbonato e a concentração de ácidos voláteis se manteve em níveis adequados. / An anaerobic sequencing batch reactor treating synthetic low strength wastewater (500 mgCOD/L-1) enriched with different sulfate concentrations (COD/[SO42] ratios of 1,34, 0,67 and 0,34) was operated at different fill times (batch mode and sequencing batch mode of 3 h and 6 h fill time). The reactor operated with a capacity of 4,0 L and treated per 8-h cycle 2,0 L of synthetic wastewater. Thus, 9 different configurations resulted from this configuration and were submitted under analyses with the objective to investigate the influence of each of those parameters on the performance of the system. The reactor was operated at a constant temperature of 30 ± 1°C and an mechanical agitation rate of 400 rpm. Cubic particles of polyurethane were used as support material for anaerobic biomass immobilization. The results showed that operating the reactor with a fill time of 3 h and a COD/[4-2] ratio of 0,34 was the most eficient strategy for COD removal (89%). During the same operation mode (3 h fill time) sulfate removal seemed to suffer stagnation due to the increasing sulfite concentation in the reactor, whereas with a fill time of 6 h the sulfate load removal increased linerally with increasing sulfate load. So the biggest removal, in terms of volumetric sulfate load, was obtained operating the reactor in sequencing batch mode with a fill time of 6 h and a COD/[4-2] ratio of 0,34. During this test the reactor removed 0,55 gSO4-2/(L.d) of 2,29 gSO4-2/(L.d) applied on the system. Operating at a COD/[SO4-2] ratio of 1,34 and a fill time of 6 h the reactor obtained the best results in terms of sulfate removal efficiency, with 71% of the sulfate removed from the system. In the entire period of analisis the reactor showed stability with a suficient production of alkalinity to maintain the concentration of volatil acids in adequate levels.
|
42 |
Morfometria baseada no voxel e sintomas neuropsiquiátricos na Doença de Alzheimer e no comprometimento cognitivo sem demência / Voxel-based morphometry and neuropsychiatric symptoms in Alzheimer\'s disease and cognitive impairment, no dementiaLyssandra dos Santos Tascone 24 June 2013 (has links)
O estudo dos sintomas neuropsiquiátricos em Doença de Alzheimer (DA) através do agrupamento destes em síndromes tem sido cada vez mais utilizado, uma vez que permitiria detectar diferenças em sua prevalência, em sua evolução, em relação a determinantes psicossociais e a correlatos neurobiológicos. O objetivo deste estudo foi identificar regiões de redução de substância cinzenta em áreas corticais associadas com sintomas e síndromes neuropsiquiátricos específicos, provenientes da Escala Inventário Neuropsiquiátricos (NPI), em pacientes com DA e comprometimento cognitivo sem demência (CIND). O método de morfometria baseada no voxel (VBM) com DARTEL (Diffeomorphic Anatomical Registration Using Exponentiated Lie Algebra) foi utilizado para verificar a correlação entre presença de sintomas e síndromes neuropsiquiátricos específicos e redução regional de volume de substância cinzenta em análise em todo cérebro e em regiões previstas a priori. As síndromes utilizadas foram SN1/Agitação (agitação, alterações de sono e apetite), SN2/Hiperatividade (desinibição, comportamento motor aberrante e irritabilidade), SN3/Afetiva (depressão e apatia) e SN4/Psicose (delírios e alucinações). A presença de delírios foi associada a volume de substância cinzenta reduzido em giro frontal inferior direito (BA45); depressão com xvii redução de substância cinzenta em giro temporal médio e inferior direito (BA 37/22) e giro frontal inferior (BA09-DLPFC) e giro parahipocampal esquerdos; ansiedade com redução em giro frontal médio esquerdo (BA10); e alterações de apetite com redução em córtex anterior cingulado esquerdo (BA32) em pacientes com DA. A presença de SN1/Agitação foi associada a volume de substância cinzenta reduzido em giro frontal médio direito (BA09-DLPFC); SN2/Hiperatividade com redução em giro temporal superior direito (BA22) e frontal inferior bilateral (BA47); e SN4/Psicose com redução em giro pré-central (BA44), temporal superior (BA22) e ínsula direitos em DA. No grupo CIND, somente SN1/Agitação evidenciou associação com redução de substância cinzenta regional. Atrofia de áreas corticais específicas parecem relacionadas aos sintomas e síndromes neuropsiquiátricos em DA. Síndromes neuropsiquiátricas em DA mostraram-se correlacionadas à atrofia de estruturas centrais de alguns circuitos neuronais envolvidos na fisiopatologia de transtornos psiquiátricos / The study of neuropsychiatric symptoms in patients with Alzheimer\'s disease (AD) by grouping these symptoms into syndromes has been increasingly used because it would detect differences in its prevalence and evolution, in relation to psychosocial determinants and neurobiological correlates. The aim of this study was to identify regions of reduced gray matter in cortical areas associated with specific neuropsychiatric symptoms and syndromes from the Neuropsychiatric Inventory (NPI) in patients with AD and cognitive impairment, no dementia (CIND). Voxel-based morphometry (VBM) plus Dartel (Diffeomorphic Anatomical Registration Exponentiated Using Lie Algebra) was used to verify the correlation between the presence of specific neuropsychiatric symptoms and syndromes and regional gray matter volume reduction throughout the brain and in regions predicted a priori. The syndromes were NS1/ Agitation (agitation, sleep and eating disorders), NS2/Hyperactivity (disinhibition, aberrant motor behavior and irritability), NS3/Affective (depression and apathy) and NS4/Psychosis (delusions and hallucinations). The presence of delusions was associated with gray matter volume reduction in right inferior frontal gyrus (BA45), depression with reduced gray matter in right inferior middle temporal gyrus (BA 37/22) and left inferior frontal gyrus (BA09-DLPFC) and left parahippocampal gyrus; anxiety with reduction in left middle frontal gyrus (BA10), and eating disorders with reduction in left anterior cingulate cortex (BA32) in patients with AD. The presence of NS1/Agitation was associated with gray matter volume reduction in the right middle frontal gyrus (BA09-DLPFC); NS2/ Hyperactivity with reduction in right superior temporal gyrus (BA22) and bilateral inferior frontal (BA47) and NS4/Psychosis with a reduction in right precentral gyrus (BA44), right superior temporal (BA22) and in right insula in AD. In the CIND group, only SN1/Agitation showed association with regional gray matter reduction. Atrophies of specific cortical areas were showed to be related to symptoms and neuropsychiatric syndromes in patients with AD
|
43 |
\"Otimização da extração, separação cromatográfica, identificação e quantificação de fármacos em fluidos biológicos\" / \"Optimization of the extraction, chromatographic separation, identification, and quantification of drugs in biological fluids\"Christian Fernandes 20 December 2006 (has links)
Este trabalho apresenta o desenvolvimento de diferentes métodos para a determinação de fluoxetina, norfluoxetina e bisfosfonatos, utilizando técnicas modernas de preparo de amostras. Dentre eles, um método simples e sensível, empregando microextração em fase sólida (SPME) e cromatografia líquida foi desenvolvido para a análise de fluoxetina e norfluoxetina em plasma. As condições de SPME foram otimizadas empregando planejamento fatorial. A extração foi realizada utilizando fibras com PDMS-DVB, e a etapa de dessorção foi realizada em uma nova interface homemade com sistema de aquecimento. Extração com sorção em barra de agitação (SBSE) com derivatização in-situ, combinada com dessorção com solventes ou dessorção térmica, acoplada à cromatografia gasosa e espectrometria de massas (GC-MS), foi também empregada para a determinação de fluoxetina em plasma. Avaliou-se a derivatização dos analitos in situ com cloroformato de etila, bem como os parâmetros tempo de extração, solvente e tempo de dessorção. A combinação de SBSE e LC-MS foi também avaliada. As amostras de plasma foram submetidas à precipitação de proteínas com ácido tricloroacético, extraídas com SBSE, e analizadas por LC-MS. Os métodos SPME-LC, SBSE-GC e SBSE-LC desenvolvidos foram completamente validados, demonstrando serem adequados para analisar fluoxetina em amostras de plasma. Métodos rápidos para a determinação de etidronato, clodronato, pamidronato e alendronato, baseados em cromatografia de troca iônica com detecção indireta no ultravioleta, foram também desenvolvidos. Os métodos são simples e demonstraram precisão, exatidão e especificidade. Além disso, os métodos validados empregam colunas de sílica, mais baratas e de mais disponibilidade do que as colunas poliméricas, frequentemente utilizadas em métodos descritos na literatura para o mesmo propósito. / This study describes different methods to analyze fluoxetine, norfluoxetine and bisphosphonates, employing modern sample preparation techniques. A simple and sensitive procedure using solid-phase microextraction (SPME) coupled with liquid chromatography was developed for the analysis of fluoxetine and norfluoxetine in plasma samples. SPME conditions were optimized employing a factorial design. The sampling step was performed using a PDMS-DVB fiber and desorption was carried out in a novel homemade heated interface. Stir bar sorptive extraction (SBSE) with in situ derivatization, in combination with either thermal or liquid desorption on-line coupled to gas chromatography-mass spectrometry (GC-MS), was employed for the analysis of fluoxetine. In situ derivatization using ethylchloroformate was evaluated as well as parameters such as solvent polarity, time for analytes desorption, and extraction time. SBSE combined with liquid chromatography and mass spectrometry was also used to analyze fluoxetine in plasma. Plasma samples were first submitted to protein precipitation with trichloroacetic acid, subjected to SBSE, and thereafter analyzed by LC-MS. SPME-LC, SBSE-GC, and SBSE-LC methods were completely validated showing to be adequate to assess fluoxetine in plasma samples. Rapid methods for etidronate, clodronate, pamidronate and alendronate assay were also developed. The methods were based on ion chromatography with indirect ultraviolet detection, which avoids the need for chemical derivatization procedures. The methods were simple, rapid, and demonstrated precision, accuracy, and specificity. Furthermore, they employed silica-based columns, cheaper and more readily available than polymeric columns, frequently used in previous reported methods.
|
44 |
Influência das condições de aplicação de polímeros catiônicos na eficiência da floculação / Influence of the conditions under which cationics polymers are applied on the efficiency of flocculationAngela Silva Di Bernardo 14 April 2000 (has links)
Tendo em vista que os amidos (catiônicos ou não) não são nocivos a saúde do ser humano, uma vez que são utilizados na indústria de alimentos, e observando-se a potencialidade do seu uso como auxiliares de floculação, foi proposto o presente trabalho. Consiste na realização de ensaios de coagulação (com sulfato alumínio), floculação e sedimentação em equipamento de reatores estáticos, objetivando verificar a influência do gradiente de velocidade e do tempo de agitação na floculação com polímero sintético catiônico e amidos de milho e mandioca catiônicos. Concluiu-se que as condições de aplicação exercem influência na eficiência de remoção de turbidez e cor aparente, sendo que cada polímero estudado apresentou uma condição ótima específica. Em todos os ensaios realizados, o amido de mandioca catiônico foi o mais eficiente, indicando que os amidos catiônicos podem ser substitutos em potencial dos polímeros sintéticos no tratamento de águas de abastecimento, quando utilizados como auxiliares de floculação. / This present work was based on the fact that native and cationic starches are not harmful to man\'s health, since they have been largely used in food processing industries, and that they may be potentially used as flocculation aids in water treatment. Jar Test assays were performed, including coagulation with aluminum sulphate, flocculation and sedimentation, aiming to study the influence of the velocity gradient and mixing time on flocculation, using a cationic synthetic polymer and cationic com and manioc starches as aids. In the main, it was concluded that the conditions under which the polymers were applied, affect the efficiency of turbidity and color removals and that each polymer studied presented an specific optimum condition. It was also observed that manioc cationic starch resulted more effective than the others polymers studied, when used as flocculation aids.
|
45 |
Desenvolvimento da fase extratora SPME de poli(pirrol) e avaliação das técnicas SPME/LC e SBSE/LC para análises de antidepressivos em amostras de plasma / Developmento of polypyrrole SPME extraction phase and evaluation of the SPME/LC and SBSE/LC techniques to antidepressants plasma samples analysesChaves, Andréa Rodrigues 27 June 2008 (has links)
A depressão em idosos é uma desordem persistente e recorrente, resultado do stress psicossocial ou efeito de doenças fisiológicas, que podem acarretar a desabilidade do indivíduo, aumento dos sintomas das doenças clínicas, na maior utilização dos serviços de saúde e altas taxas de suicídios.A monitorização terapêutica permite a ndividualização do regime de dosagem, assegurando a eficácia clínica e minimizando os efeitos adversos dos fármacos, prescritos na clínica. Os antidepressivos têm sido monitorados, pois, apresentam intervalos terapêuticos bem estabelecidos, ou seja, a maioria dos pacientes, que apresentam concentrações plasmáticas dentro deste intervalo fixo, tem as desordens psiquiátricas mantidas sob controle e efeitos adversos aceitáveis. Os antidepressivos tricíclicos (ADTs): imipramina, amitriptilina, nortriptilina e desipramina, embora eficazes e ainda muito utilizados, apresentam efeitos adversos, não desejáveis. Os antidepressivos, inibidores seletivos da recaptação de serotonina (SSRIs): citalopram, fluoxetina, paroxetina e sertralina, apresentam eficácia clínica comparável aos clássicos ADTs, mas destituídos dos efeitos adversos associados aos mesmos. Os métodos convencionais, empregados no tratamento de amostras biológicas, para análises de antidepressivos por técnicas cromatográficas, têm sido a extração líquido-líquido e extração em fase sólida. A microextração em fase sólida tem sido empregada em diferentes análises em fluidos biológicos, porém essa técnica apresenta certas limitações como, o número limitado de fases extratoras disponíveis no comércio que sejam adequadas para a análise de compostos não iônicos. A avaliação de novas fases extratoras, mais seletivas, estáveis e de baixo custo tem sido requerida para a análise de fármacos. O interesse no uso de poli(pirrol) (PPY), como fase extratora para SPME, está relacionado às diferentes interações dos fármacos (hidrofóbicas, -, com o grupo funcional polar, troca iônica, ácido-base) aos grupos multifuncionais deste polímero. Sua polimerização pode ser alcançada tanto por oxidação química, quanto por eletrodeposição em meio aquoso ou orgânico. O método eletroquímico apresenta algumas vantagens, tais como: o polímero ou mistura de polimeros podem ser revestidos diretamente em um metal, incorporação de diferentes grupos funcionais, entre outras, a polimerização pode ser eletroquimicamente controlada através da voltametria cíclica. Neste trabalho o poli(pirrol) (PPY) foi eletrodepositado em eletrodo de aço inox e empregado para a microextração em fase sólida dos antidepressivos: paroxetina, fluoxetina, mirtazapina, duloxetina, sertralina e citalopram. As variáveis da eletrodeposição, número de ciclos e contra-íon empregado no processo de eletrodeposição foram otimizadas. Assim como as variáveis SPME: tempo, temperatura, pH e volume de amostra, e tempo e solvente de dessorção; almejando maior sensibilidade para o método SPME-PPY/LC UV proposto. A extração sortiva em barra de agitação (SBSE), técnica recente de preparo de amostras, para a pré-concentração de compostos orgânicos presentes em amostras biológicas, baseia-se na extração estática, através do polímero polidimetilsiloxano (PDMS), no qual ocorre a dissolução (sorção) do analito. Neste trabalho, as técnicas SBSE e cromatografia líquida de alta eficiência com detecção UV (SBSE/LC UV) foram avaliadas para a análise simultânea de antidepressivos em amostras de plasma para fins de monitorização terapêutica. As condições cromatográficas de análise, assim como as variáveis SBSE de extração (tempo, temperatura, força iônica, pH da matriz) e tempo de dessorção, foram otimizadas, visando adequada sensibilidade analítica. A validação analítica foi realizada segundo normas da ANVISA, para ambos os métodos propostos, em diferentes concentrações plasmáticas, as quais contemplam o intervalo terapêutico. Segundo os parâmetros de validação avaliados, os métodos SBSE/LCUV e SPMEPPY/LCUV padronizados poderão ser empregados nas análises dos antidepressivos, para fins de monitorização terapêutica. / Depression in the elderly is a persistent and recurrent disorder resulting from psychosocial stress or physiological effect or disease. This condition can lead to disability, cognitive impairment, enhanced symptoms of medical illnesses, increased use of health care services and, increased of suicide rates. Therapeutic monitoring allows individualization of the dose regimen, ensuring clinical effectiveness and minimizing the adverse effects of drugs, prescribed at the clinic. Antidepressants have been monitored because they present well - established therapeutic intervals; in other words, most of the patients present plasmatic concentrations within this fixed range, so that their psychiatric disorders are kept under control and the adverse effects are acceptable. The tricyclic antidepressants (ADTs) imipramine, amitriptyline, nortryptiline, and desipramine, have adverse effects. The selective serotonin reuptake inhibitors (SSRIs) antidepressants citalopram, fluoxetine, paroxetine, and sertraline, are clinically effectiveness as the classic ADTs, but they do not lead to the adverse effects associated to the latter. The conventional methods employed in the treatment of biological samples for analysis of antidepressants by chromatographic techniques have been the liquid-liquid extraction (LLE) and solid phase extraction (SPE) techniques. Solid-phase microextraction (SPME) has been used in various analyses of biological fluids. However, this technique has limitations such as the small number of comemercially available extracting phases that are appropriate for the analysis of non-ionic compounds. Investigation of new extraction phases that are more selective and stable, as well as inexpensive, has been requested for drug analysis. The interest in the use of poly(pirrole) (PPY) as an extraction phase for SPME is related to the different interactions of the drugs (hydrophobic, - , with the polar functional group, ionic exchange and acid-base) with the multifunctional groups on this polymer. The PPY polymerization can be achieved by chemical oxidation or electropolymerization in aqueous solution or organic solvents. The electrochemical method has advantages such as, the polymer or a mixes of polymers can be directly deposited on a metal wire, different functional groups can be incorporated, polymerization can be electrochemically controlled by cyclic voltammetry. In this work poly(pyrrole) was electropolymerized on stainless steel electrodes and employed for the solid phase microextraction of the antidepressants paroxetine, fluoxetine, mirtazapine, duloxetine, sertraline, and citalopram. The electropolymerization variables, the number of cycles and counterion employed in the process were optimized, as well as the SPME variables, time, temperature, pH, sample volume, and desorption solvent; aiming at a better sensibility for the proposed method SPME-PPY/LC-UV. The stir bar sorptive extraction (SBSE), recently established technique for samples preparation, that targets the pre concentration of organic compounds present in biological samples. It is based on static extraction, through the polymeric polydimethylsiloxane (PDMS), where there is analyte dissolution (sorption). In this work, the SBSE technique and liquid chromatography with UV detector (SBSE/LC-UV) were evaluated for the simultaneous determination of antidepressants in plasma samples for therapeutic monitoring purposes. The cromatographic conditions, the SBSE extraction variables (time, temperature, ionic strength and matrix pH), and the dessorption time were optimized for appropriate analytical sensibility. The analytical validation was accomplished according to the norms of ANVISA for both of the proposed methods, in different plasmatic concentrations, which contemplate the therapeutic interval. According to the evaluated validation parameters, the standardized methods SBSE/LC-UV and SPME-PPY/LC-UV can be used in the analyses of antidepressants for therapeutic drug monitoring purposes.
|
46 |
Desenvolvimento e aplicação de uma nova fase para extração por sorção em barra de agitação (SBSE) / Development and application of a new phase for stir bar sorptive extraction (SBSE)Barletta, Juliana Yamashita 17 December 2010 (has links)
Uma fase polimérica inédita de polidimetilsiloxano/carvão ativado (PDMS-ACB) é proposta como fase extratora para extração por sorção em barras de agitação (SBSE). A barra de PDMS-ACB foi desenvolvida no laboratório usando um molde de teflon simples, demonstrando estabilidade e resistência aos solventes orgânicos. Utilizando uma única barra de PDMS-ACB mais de 150 extrações foram realizadas sem qualquer dano. A barra de SBSE contém aproximadamente 100 µL de revestimento polimérico, 2,36 mm de diâmetro e 2,2 cm de comprimento. A barra PDMS-ACB foi aplicada na extração de seis pesticidas (ametrina, atrazina, bifentrina, carbofurano, metribuzim e tebutiurom), com propriedades predominantemente polares, comumente aplicados em plantações de cana-de-açúcar. A barra PDMS-ACB foi utilizada na determinação de pesticidas em garapa através de cromatografia gasosa hifenada à espectrometria de massa (GC-MS). O planejamento experimental foi empregado na etapa de otimização da extração SBSE, um planejamento fatorial fracionado avaliou a influência dos principais parâmetros envolvidos. Posteriormente, o planejamento composto central (CCD) com conformação estrela foi explorado para otimizar os fatores significativos na extração. Apenas 200 µL de acetato de etila foram utilizados como solvente na dessorção líquida (LD). Para os compostos avaliados, o método apresentou limite de quantificação (LOQ) no intervalo de 0,5 - 40 µg L-1, as recuperações variaram entre 0,18 - 49,50 % e a precisão intra-dia variou de 0,072 - 8,40 %. Concluída a etapa de validação, o método foi aplicado em amostras reais de garapa disponíveis comercialmente em São Carlos-SP. / A novel polydimethylsiloxane/activated carbon (PDMS-ACB) is proposed as new polymeric phases for stir bar sorptive extraction (SBSE). The PDMS-ACB was developed in lab using simple teflon\'s mold, demonstrating remarkable stability and resistance to organic solvents, over 150 extractions without any damage. SBSE bar contained 100 µL of polymeric coating, a diameter of 2.36 mm and a length of 2.2 cm. It was applied to the determination of pesticides (ametryn, atrazine, bifenthrin, carbofuran, metribuzine and tebuthiuron) having predominantly polar properties, applied in sugarcane crops. PDMS-ACB was employed in the determination of pesticides in sugarcane juice using gas chromatography coupled to mass spectrometry (GC-MS). Experimental design was employed in the optimization step, a fractional factorial evaluated the main parameters involved in the extraction procedure. Afterwards, central composite design (CCD) was exploited to optimize the significant factors on the extraction. About 200 µL of ethyl acetate were employed as solvent in the liquid desorption (LD). The method presented limit of quantification (LOQ) from 0.5 to 40 µg L-1, recoveries varied 0.18 - 49.50% and precision intra-day 0.072 - 8.40%. Hence, the method was applied to the analysis of real sugarcane juice samples commercially available in São Carlos-SP.
|
47 |
Desenvolvimento das barras imunosorventes de agitação e avaliação das técnicas extração sortiva em barra de agitação, microextração em sorvente empacotado e cromatografia líquida para análise de antidepressivos em amostras de plasma / Development of immunosorbent stir bars and evaluation of stir bar sorptive extraction, microextraction by packed sorbent and liquid chromatography for the analysis of antidepressants in plasma samplesLeandro, Fernanda Zampieri 15 December 2010 (has links)
Neste trabalho, os anticorpos policlonais e monoclonais anti-fluoxetina foram produzidos em coelhos e camundongos, respectivamente, por imunização com o conjugado fluoxetina-soroalbumina bovina. Os anticorpos obtidos foram caracterizados em função da especificidade contra o fármaco por ELISA (enzyme linked immunosorbent assay) e posteriormente, purificados por afinidade em coluna fluoxetina-agarose labmade. Os anticorpos purificados foram imobilizados covalentemente na superfície vítrea das barras SBSE (extração sortiva em barra de agitação) labmade. Após a derivatização das barras com 3-aminopropiltrietoxisilano, dois métodos distintos de acoplamento dos anticorpos às barras SBSE foram avaliados: ativação com glutaraldeído e succinilação seguida de ativação via éster N-hidroxisuccinimida (NHS). A funcionalização das barras SBSE foi comprovada através da imobilização de enzima peroxidase (HRP) em lugar do anticorpo e posterior ensaio enzimático com as barras. Várias barras SBSE com diferentes áreas (1,2; 2,4; e 4,0 cm2) foram preparadas, dentre as quais, as com maior área imunosorvente apresentaram maiores taxas de recuperação do fármaco. A avaliação da morfologia da superfície da barra SBSE imunosorvente foi realizada através de Microscopia Eletrônica de Varredura (MEV). As variáveis do processo SBSE de imunoafinidade foram otimizadas para estabelecer o equilíbrio de sorção antígeno-anticorpo em um menor tempo de análise e obtenção de limite de quantificação compatível com o intervalo terapêutico do fármaco. As capacidades adsortivas das barras imunosorventes foram de 1,2 e 8 microgramas por cm2 para anticorpos policlonais e monoclonais, respectivamente. Os imunosorventes desenvolvidos apresentaram reatividade-cruzada apenas com norfluoxetina (metabólito ativo de fluoxetina). As barras imunosorventes foram reutilizadas aproximadamente 30 vezes, sem perda significativa da eficiência das extrações. Baseados nos parâmetros de validação analítica avaliados, os métodos de SBSE/LC-FD de imunoafinidade desenvolvidos são adequados para a determinação de fluoxetina em amostras de plasma de pacientes em terapia com o fármaco, para fins de monitorização terapêutica. Por conseguinte, esses métodos foram aplicados com êxito para análises de amostras de plasma de pacientes idosos em terapia com Prozac®. Neste trabalho, o método MEPS (microextração em sorvente empacotado)/LC-UV também foi desenvolvido e validado para análise simultânea de sertralina, paroxetina, citalopram, fluoxetina e mirtazapina em amostras de plasma para fins de monitorização terapêutica. As variáveis do processo MEPS foram otimizadas (pH e volume da amostra, força iônica, volume dos ciclos aspirar-dispensar e condições de dessorção) para estabelecer o equilíbrio de sorção em menor tempo de análise e obter sensibilidade analítica adequada para a determinação dos antidepressivos no intervalo terapêutico. O método MEPS/LC-UV desenvolvido permitiu integração da dessorção dos analitos e injeção da amostra no sistema cromatográfico (LC-UV) em uma única etapa, usando a microsseringa de extração MEPS. A fase extratora MEPS, M1 (C8/SCX), foi reutilizada mais de 50 vezes com perda mínima da eficiência da extração, comprovando a robustez do material sorvente. Segundo os parâmetros de validação analítica avaliados, o método MEPS/LC-UV desenvolvido é adequado para a determinação de antidepressivos em amostras de plasma para fins de monitorização terapêutica. / In this work, polyclonal and monoclonal anti-fluoxetine antibodies were developed in rabbits and mice by immunization with fluoxetine-bovine albumin conjugate, respectively. The developed antibodies were characterized on the basis of the specificity against the drug by ELISA (enzyme linked immunosorbent assay) and, subsequently they were purified by labmade fluoxetine-agarose affinity column. The purified antibodies were covalently immobilized onto the glass surface of labmade SBSE (stir bar sorptive extraction) bars. After derivatization of the bars with 3-aminopropyltriethoxysilane, two distinct methods were evaluated for the antibodies coupling to the SBSE bars: activation with glutaraldehyde and succinylation activation via ester N-hydroxysuccinimide (NHS). The functionalization of SBSE bars was confirmed by the immobilization of peroxidase (HRP) instead of the antibody and, subsequent enzymatic assay with the bars. Several SBSE bars with different areas (1.2, 2.4, and 4.0 cm2) were prepared, among of them the largest immunosorbent area showed higher recovery rates of the drug. The evaluation of surface morphology of the SBSE immunosorbent bar was performed using scanning electron microscopy (SEM). The SBSE immunoaffinity variables were optimized to establish sorption equilibrium of antigen-antibody in a short time analysis and to obtain the limit of quantification compatible with the therapeutic range of the drug. The adsorptive capacities of the immunosorbent bars were 1.2 and 8 micrograms per cm2 for polyclonal and monoclonal antibodies, respectively. The developed immunosorbents showed cross-reactivity only with norfluoxetine (active metabolite of fluoxetine). The immunosorbent bars were reused approximately 30 times without significant loss of the extraction efficiency. Based on evaluated analytical validation parameters, the developed immunoaffinity SBSE/LC-FD methods are suitable for the determination of fluoxetine in plasma samples from patients on therapy with the antidepressant for therapeutic drug monitoring. Therefore, these methods were successfully applied for the analysis of plasma samples from elderly patients undergoing therapy with Prozac®. In this work, the method MEPS (microextraction by packed sorbent)/ LC-UV was also developed and validated for the simultaneous analysis of sertraline, paroxetine, citalopram, fluoxetine and mirtazapine in plasma samples for therapeutic drug monitoring. The MEPS process variables were optimized (pH, sample volume, ionic strength, draw-eject cycles volume and desorption conditions) to establish the sorption equilibrium in a short time analysis and to obtain adequate analytical sensitivity for determination of antidepressants within therapeutic range. The developed MEPS/LC-UV method allowed integration of the analytes desorption and sample injection in the chromatographic system (LC-UV) in a single step, using a MEPS extraction microsyringe. The MEPS extraction phase, M1 (C8/SCX) was reused over 50 times with minimum loss of extraction efficiency, proving the robustness of the sorbent material. According to the evaluated analytical validation parameters, the developed MEPS/LC-UV method is suitable for the determination of antidepressants in plasma samples for therapeutic drug monitoring.
|
48 |
Avaliação da recirculação da fase líquida e do regime de alimentação no reator anaeróbio, em escala piloto, operado em bateladas seqüenciais contendo biomassa imobilizada (ASBBR), no tratamento de esgoto sanitário / Influence of the liquid phase recirculation and the feeding regimen on a pilot anaerobic immobilized biomass sequencing batch reactor treating domestic sewageLapa, Katt Regina 19 December 2006 (has links)
Avaliou-se a influência da recirculação da fase líquida e do regime de alimentação em reator anaeróbio no tratamento de esgoto sanitário. Utilizou-se um reator anaeróbio operado em bateladas seqüenciais, contendo biomassa imobilizada (ASBBR), em escala piloto, com volume total de 1,2 \'M POT.3\' (\'fi\' 1,0 m e altura 1,53 m). O leito suporte para a imobilização da biomassa era constituído por matrizes cúbicas de espuma de poliuretano, com 5 cm de aresta, confinadas em cesto de aço inox 304, colocado no interior do reator. A influência da recirculação da fase líquida sobre o desempenho do ASBBR quanto à remoção de matéria orgânica e quanto ao arraste de sólidos foi avaliada submetendo-se o reator às velocidades ascensionais de 1,27; 3,82; 7,64 e 10,18 m/h resultantes das diferentes vazões de recirculação impostas. Contrariamente ao observado em pesquisas anteriores em reatores operados em escala de bancada e alimentados com água residuária sintética, não houve aumento significativo da eficiência do reator com o aumento da velocidade ascensional no tratamento de esgoto sanitário. A influência do regime de alimentação de esgoto sanitário no desempenho do ASBBR foi avaliada submetendo-se o reator a tempos de enchimento correspondentes a 0,25 e 0,5 do tempo total de ciclo, utilizando-se a vazão de recirculação de 6 \'M POT.3\'/h, que foi a que apresentou os melhores resultados nos ensaios anteriores. Concluiu-se que o reator pode ser operado sob batelada alimentada com duração de até 0,5 tempo de ciclo, sem que seu desempenho seja significativamente alterado. Esse resultado é importante, pois representa que o sistema de tratamento composto por reatores ASBBR pode ser projetado com número menor de reatores. A fim de esclarecer dúvidas sobre o desempenho do ASBBR observado no tratamento de água residuária de composição complexa (esgoto sanitário), o reator foi alimentado com água residuária facilmente degradável (etanol). O desempenho do reator foi aquém do esperado, mesmo quando alimentado com composto de fácil degradação. Os ensaios de atividade metanogênica específica (AME) demonstraram que houve decréscimo dos valores de AME com o aumento da velocidade ascensional. Os valores obtidos foram 0,0632; 0,0509; 0,0248 e 0,0299 g DQO-CH4/(g STV.d), respectivamente, para os valores de Va de 1,27; 3,82; 7,64 e 10,19 m/h. Concluiu-se que a baixa eficiência de remoção de matéria orgânica deveu-se ao abaixamento progressivo da atividade metanogênica do lodo, cujas causas não puderam ser completamente esclarecidas nesta pesquisa. / The influence of the liquid phase recirculation and the feeding regimen on the performance of an anaerobic sequencing batch reactor containing immobilized biomass (ASBBR) applied for the treatment of domestic sewage was evaluated. Biomass immobilization was provided by a basket containing cubic polyurethane foam matrices (5 cm side) inside the 1.2 \'M POT.3\' (1.0 m diameter and 1.53 m height) pilot-scale reactor. The influence of the liquid phase recirculation on the reactor performance in respect to organic matter and solids wash-out was verified by subjecting the reactor to a wide range of up flow velocities (1.27; 3.82; 7.64 and 10.18 m/h) resulting from different recirculation flow rates imposed. The increase of the up flow velocity did not increase the efficiency of the pilot reactor as expected. This result contradicts those obtained with bench-scale ASBBR experiments treating synthetic wastewaters. The influence of the feeding regimen was verified by subjecting the reactor to feeding times correspondent to 0.25 and 0.50 of the total cycle time, at the recirculation flow rate of 6 \'M POT.3\'/h. It could be concluded that the reactor can be operated at the feeding batch mode up to 0.5 of the cycle time. This result is important for full scale applications considering that a treatment system composed of ASBBR reactors can be designed using a lower number of units. In order to clear some aspects related to the limited performance of the ASBBR reactor treating a complex wastewater (sewage), the reactor was subjected to an easily degradable wastewater (ethanol). However, the performance was not improved even when the reactor was treating an easily degradable compound. The results from the specific methanogenic activity (SMA) demonstrated a decrease on the values of SMA with the increase of the up flow velocity. The values of SMA were 0.0632; 0.0509; 0.0248 and 0.0299 g DQO-CH4/(g STV.d) for the Va of 1.27; 3.82; 7.64 and 10.19 m/h respectively. It could be concluded that the low efficiency obtained for organic matter removal was due mainly to the progressive decrease of the sludge methanogenic activity. The causes for that behaviour could not be completely explained in this research. It could be concluded that the reactor performance was iv clearly limited by the low productivity of the methanogenic populations present in the biomass.
|
49 |
Avaliação das técnicas de microextração e eletroforese capilar em meio não aquoso (NACE) para determinação de antidepressivos em amostras de plasma para fins de monitorização terapêutica / Evaluation of microextractions techniques and nonaqueous capillary electrophoresis (NACE) for the determination of antidepressants in plasma samples for therapeutic drug monitoringCatai, Ana Paula Formenton 02 March 2012 (has links)
A monitorização terapêutica tem sido descrita como um recurso clínico valioso, na individualização do regime de dosagem, de acordo com a concentração do fármaco em amostras de plasma ou soro. O objetivo da monitorização terapêutica é assegurar a eficácia clínica e minimizar os efeitos adversos dos fármacos prescritos na clínica. A química analítica moderna tem sido direcionada para a simplificação dos métodos através da miniaturização dos sistemas analíticos, minimização do consumo de solvente orgânico e do volume da amostra. Neste contexto, metodologias analíticas utilizando as técnicas de microextração, extração sortiva em barra de agitação (SBSE) e microextração em sorvente empacotado (MEPS), juntamente com a eletroforese capilar em solução não-aquosa (NACE) foram desenvolvidas para fins monitorização terapêutica de antidepressivos inibidores seletivos da recaptação de serotonina (ISRSs: fluoxetina, sertralina, paroxetina e citalopram) em amostras de plasma de pacientes em terapia com ISRSs. Inicialmente foram padronizadas as condições eletroforéticas com detecção espectrofotométrica (UV) para análise simultânea dos ISRSs em amostras de plasma. Dentre as condições avaliadas (diferentes soluções de eletrólitos em meio aquoso e não aquoso, cromatografia eletrocinética micelar e NACE), a técnica NACE-UV foi a única que apresentou resolução dos fármacos adequada. Em seguida, otimizou-se as variáveis inerentes das técnicas de microextração (SBSE e MEPS), visando minimizar o tempo de análise e aumento da sensibilidade analítica. Para o método SBSE/NACE, as variáveis tempo e temperatura de extração, pH da amostra biológica e processo de dessorção foram otimizadas, já para o método MEPS/NACE, as variáveis, pH da amostra biológica, volume da amostra e número dos ciclos aspirar/dispensar foram otimizadas. A validação analítica foi realizada segundo as normas preconizadas pela Agência Nacional de Vigilância Sanitária (ANVISA), com adição de padrão de padrão interno às amostras de plasma enriquecidas com os antidepressivos em diferentes concentrações plasmáticas que contemplam o intervalo terapêutico dos ISRSs. Para avaliar a aplicabilidade das metodologias padronizadas, amostras de plasma de pacientes em terapia com os ISRSs foram analisadas. Os métodos padronizados (SBSE/NACE e MEPS/NACE) foram comparados ao método de referência (LLE/NACE), utilizando a extração líquido-líquido. As técnicas de microextração, quando comparadas à LLE, apresentaram as seguintes vantagens: a reutilização das fases extratoras, procedimentos de extração com reduzido número de etapas, menores volumes de amostras biológicas e de solventes orgânicos. Segundo os parâmetros de validação avaliados, os métodos SBSE/NACE e MEPS/NACE padronizados podem ser empregados nas análises dos antidepressivos (ISRSs) em amostras de plasma, para fins de monitorização terapêutica. / Therapeutic monitoring allows individualization of the dose regimen and has been indicated for the monitoring of well-established therapeutic intervals. In psychiatric disorders, most of the patients require that the plasmatic concentrations to be within a fixed range, so the disorders are kept under control and the adverse effects are acceptable. The aim of the therapeutic monitoring is ensure clinical effectiveness and minimization of adverse effects of drugs prescribed at the clinic. New trends in analytical chemistry have been directed towards simplification and miniaturization of analytical systems, and minimization of organic solvents and sample volume. In this work, analytical methodologies using microextraction techniques, such as stir bar sorptive extraction (SBSE) and microextraction by packed sorbent (MEPS), in conjunction with capillary electrophoresis in a nonaqueous background electrolyte (NACE) were developed for therapeutic drug monitoring of selective serotonin reuptake inhibitors (SSRIs: fluoxetine, sertraline, paroxetine and citalopram) in plasma sample of patients in therapy with SSRIs. First, the optimization of electrophoretic separation of the SSRIs was carried out to obtain simultaneous analysis of all antidepressants. Among the conditions evaluated (different background electrolytes in aqueous and nonaqueous medium, micellar electrokinetic capillary chromatography, and NACE), NACE-UV gave the best results. In the sequence, the optimization of the inherent variables of microextraction techniques (SBSE and MEPS)aiming analyses time minimization and increase of analytical sensibilitywas carried out. For SBSE/NACE methodology development the variables such as time of extraction, temperature of extraction, and matrix pH were optimized. For MEPS/NACE methodology the variables matrix pH and the volume of draw-eject cycles were optimized. Analytical validation was carried out in agreement with the norms of National Health Surveillance Agency (ANVISA) for both of the proposed methods, in different plasmatic concentrations, which completed the therapeutic interval. The developed methods (SBSE/NACE e MEPS/NACE) were compared to the reference method, using liquid-liquid extraction (LLE/NACE). Microextraction techniques, compared to LLE, gave the following advantages: reutilization of the extraction phase, fewer numbers of steps for extraction, reduction of sample volume, and less consumption of organic solvents. According to the evaluated validation parameters, the standardized methods SBSE/NACE and MEPS/NACE can be used in the analyses of antidepressants (SSRIs) in plasma sample for therapeutic drug monitoring purposes.
|
50 |
Padronização e validação do método extração sortiva em barra de agitação e cromatografia líquida de alta eficiência (SBSE/HPLC) para a determinação de antidepressivos em amostras de plasma / Standardization and validation of the stir-bar sorptive-extraction and high-performance liquid chromatography (SBSE/HPLC) method for antidepressant determination in plasma samplesSilva, Silvana Maciel 13 April 2007 (has links)
A monitorização terapêutica permite a individualização do regime de dosagem, assegurando a eficácia clínica e minimizando os efeitos adversos dos fármacos, prescritos na clínica. Os antidepressivos têm sido monitorados, pois, apresentam intervalos terapêuticos bem estabelecidos, ou seja, a maioria dos pacientes, que apresentam concentrações plasmáticas dentro deste intervalo fixo, tem as desordens psiquiátricas mantidas sob controle e efeitos adversos aceitáveis. Os antidepressivos tricíclicos (ADTs): imipramina, amitriptilina, nortriptilina e desipramina, embora eficazes e ainda muito utilizados, apresentam efeitos adversos, não desejáveis. Os antidepressivos, inibidores seletivos da recaptação de serotonina (ISRSs): citalopram e sertralina, apresentam eficácia clínica comparável aos clássicos ADTs, mas destituídos dos efeitos adversos associados aos mesmos. Os métodos convencionais, empregados no tratamento de amostras biológicas, para análises de antidepressivos por técnicas cromatográficas, têm sido a extração líquido-líquido e extração em fase sólida. A extração sortiva em barra de agitação (SBSE), técnica recente de preparo de amostras para a préconcentração de compostos orgânicos presentes em amostras biológicas, baseiase na extração estática, através do polímero polidimetilsiloxano (PDMS), no qual ocorre a dissolução (sorção, partição) do analito. Neste trabalho, as técnicas SBSE e cromatografia líquida de alta eficiência foram avaliadas para a análise simultânea dos antidepressivos em amostras de plasma para fins de monitorização terapêutica. As condições cromatográficas de análise, assim como as variáveis SBSE de extração (tempo, temperatura, força iônica, pH da matriz) e tempo de dessorção, foram otimizadas, visando adequada sensibilidade analítica. A validação analítica foi realizada segundo normas da ANVISA, em diferentes concentrações plasmáticas, as quais contemplam o intervalo terapêutico. O método SBSE/HPLC padronizado apresentou linearidade na faixa de concentração plasmática de 20 a 1000 ng mL-1, precisão interensaio com coeficientes de variação menor que 14% e recuperação relativa de 83 a 110%. Segundo a validação analítica, a metodologia SBSE/HPLC apresentou linearidade, alta sensibilidade, seletividade e precisão analítica adequadas para a análise dos antidepressivos: imipramina, amitriptilina, nortriptilina, desipramina, citalopram e sertralina, em amostra de plasma, para fins de monitorização terapêutica. / Therapeutic drug monitoring allows individualization of drug dosage assuring its clinical efficacy and at the same time minimizing adverse effects of the drugs prescribed in clinics. The antidepressants have been monitored since they present a very well established therapeutic interval. In this sense, most of the patients whose plasmatic concentrations are ranged at that interval present psychiatric disorders under control and drug adverse effects at bearable levels. Despite tricyclic antidepressants (TCAs) such as imipramine, amitriptyline, nortriptyline and desipramine are highly efficient and widely used, they also present undesirable adverse effects. The antidepressants: citalopram and sertraline, which are selective serotonin reuptake inhibitors (SSRIs), present clinical efficacy comparable to the classic TACs, but with no adverse effects associated to the last ones. Liquid-liquid extraction (LLE) and solid phase extraction (SPE) have been usually employed in biological sample pre-treatment for chromatographic analysis. A new technique named sorptive stir bar extraction (SBSE) for sample pre-concentration of organic compounds from biological samples was recently proposed. This technique is based on static extraction through the polymer polidimetilsiloxane (PDMS), in which analyte sorption occurs. In this work, SBSE and HPLC techniques have been evaluated for out antidepressants simultaneous analysis in plasma samples for therapeutic drug monitoring. The chromatographic conditions of analysis, as well as SBSE parameters (time, temperature, ionic strength, matrix pH, desorption time) have been optimized in order to obtain best analytical sensitivity. Analytical validation was carried out according to the norms established by ANVISA, in different plasmatic concentrations, which represent the therapeutic interval. The SBSE/HPLC method developed showed linearity in a concentration plasmatic ranging from 20 to 1000 ng mL-1, inter assay precision with coefficient of the variation lower than 14%, and relative recovery from 83 a 110%. Based on analytical validation, the SBSE/HPLC methodology showed good linearity, high sensitivity, selectivity and suitable repeatability to the analyzed antidepressants: imipramine, amitriptyline, nortriptyline, desipramine, citalopram and sertraline in plasma samples for therapeutic drug monitoring.
|
Page generated in 0.0476 seconds