• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 2
  • Tagged with
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo de eficiência da ventilação em sistema de climatização com distribuição de ar pelo piso. / Ventilation effectiveness study of an underfloor air distribution system.

Marè, Renata Maria 21 May 2010 (has links)
A aplicação de sistemas de climatização com distribuição de ar pelo piso tem aumentado em países desenvolvidos, o que também tem ocorrido no Brasil. Em paralelo, tem crescido o interesse pela qualidade do ar interior e os seus efeitos no bem estar, saúde e produtividade dos ocupantes de uma edificação. Diversos estudos têm apontado para as vantagens deste sistema em relação à remoção de contaminantes do ambiente interior. Este sistema tem figurado nos programas de certificação ambiental de edificações como uma alternativa vantajosa para a melhoria da qualidade do ar interior e o conforto térmico com preservação da eficiência energética, recebendo pontuação adicional. Com o crescente interesse por este tipo de sistema, estudos que aprimorem o seu projeto visando à melhor eficiência global mostram-se essenciais. Este estudo tem como principal objetivo verificar experimentalmente a contribuição de um sistema de climatização com distribuição de ar pelo piso para a qualidade do ar interior de um ambiente, sendo este uma sala de aula para 48 alunos situada no Departamento de Engenharia de Construção Civil da Escola Politécnica da Universidade de São Paulo, em condições reais de uso. Para isso, foram medidas as concentrações de partículas em suspensão na zona de respiração para pessoas sentadas (a 1,10 m do piso), e no retorno do ar (a 2,60 m do piso) simultaneamente, sob seis diferentes valores de temperatura do ar na zona ocupada (a 0,60 m do piso), previamente escolhidos. Estas concentrações permitiram o cálculo e a análise do índice de efetividade na remoção de contaminantes IERC no ambiente, para partículas e CO2 (segunda etapa das medições). Simultaneamente, foram realizadas medições de variáveis de conforto térmico no ambiente, temperatura do ar e velocidade do ar, em seis diferentes alturas e quatorze pontos do ambiente. As baixas concentrações de partículas em suspensão (inferiores a 0,035 mg/m³) mostraram que este sistema não dispersa contaminantes no ar interior. Os IERC próximos ou superiores à unidade em todas as condições de operação do sistema, tanto para partículas em suspensão como para CO2, comprovaram a sua eficiência na remoção de contaminantes do ambiente interior. / The use of underfloor air distribution (UFAD) systems is growing in developed countries, and this is also observed in Brazil. Besides, the interest in indoor air quality and its effects on the well being, health and productivity of the occupants in a building is an important issue nowadays. Many studies have related the advantages of UFAD systems in removing indoor air contaminants from the ambient as compared to overhead systems. In the building certification systems, they figure as good alternatives to promote better indoor air quality and thermal comfort, preserving energy efficiency, which corresponds to additional points. With the expanding interest in this technology, studies that enhance its project, keeping as a goal its global efficiency, are very welcome. The aim is to experimentally verify the contribution of an UFAD system to the indoor air quality of a classroom used by 48 students at the Civil Construction Department of the Engineering School of the University of São Paulo Brazil. The study has been conducted in a non-steady state condition. In order to perform this evaluation, the levels of indoor air-borne particles were measured at the breathing zone for seated people (1.10m from the ground), and at the exhaust (2.60m from the ground) simultaneously, under six different pre-defined values of air temperature at the occupied zone (0.60m from the ground). These concentration levels have allowed calculating the contaminant removal effectiveness index, CRE, in many points of the ambient. A similar analysis was developed for the concentrations of CO2 in the second part of the experiment. At the same time, the air temperature and air velocity were measured in six different levels and at fourteen points of the ambient. The low concentration levels of total suspension particle (under 0.035 mg/m³) have shown that this system doesn\'t disperse air contaminants indoors. The CRE indexes near or above 1.0, for both total suspension particle and CO2, have confirmed the ventilation effectiveness of this underfloor air distribution system under all the operational conditions.
2

Estudo de eficiência da ventilação em sistema de climatização com distribuição de ar pelo piso. / Ventilation effectiveness study of an underfloor air distribution system.

Renata Maria Marè 21 May 2010 (has links)
A aplicação de sistemas de climatização com distribuição de ar pelo piso tem aumentado em países desenvolvidos, o que também tem ocorrido no Brasil. Em paralelo, tem crescido o interesse pela qualidade do ar interior e os seus efeitos no bem estar, saúde e produtividade dos ocupantes de uma edificação. Diversos estudos têm apontado para as vantagens deste sistema em relação à remoção de contaminantes do ambiente interior. Este sistema tem figurado nos programas de certificação ambiental de edificações como uma alternativa vantajosa para a melhoria da qualidade do ar interior e o conforto térmico com preservação da eficiência energética, recebendo pontuação adicional. Com o crescente interesse por este tipo de sistema, estudos que aprimorem o seu projeto visando à melhor eficiência global mostram-se essenciais. Este estudo tem como principal objetivo verificar experimentalmente a contribuição de um sistema de climatização com distribuição de ar pelo piso para a qualidade do ar interior de um ambiente, sendo este uma sala de aula para 48 alunos situada no Departamento de Engenharia de Construção Civil da Escola Politécnica da Universidade de São Paulo, em condições reais de uso. Para isso, foram medidas as concentrações de partículas em suspensão na zona de respiração para pessoas sentadas (a 1,10 m do piso), e no retorno do ar (a 2,60 m do piso) simultaneamente, sob seis diferentes valores de temperatura do ar na zona ocupada (a 0,60 m do piso), previamente escolhidos. Estas concentrações permitiram o cálculo e a análise do índice de efetividade na remoção de contaminantes IERC no ambiente, para partículas e CO2 (segunda etapa das medições). Simultaneamente, foram realizadas medições de variáveis de conforto térmico no ambiente, temperatura do ar e velocidade do ar, em seis diferentes alturas e quatorze pontos do ambiente. As baixas concentrações de partículas em suspensão (inferiores a 0,035 mg/m³) mostraram que este sistema não dispersa contaminantes no ar interior. Os IERC próximos ou superiores à unidade em todas as condições de operação do sistema, tanto para partículas em suspensão como para CO2, comprovaram a sua eficiência na remoção de contaminantes do ambiente interior. / The use of underfloor air distribution (UFAD) systems is growing in developed countries, and this is also observed in Brazil. Besides, the interest in indoor air quality and its effects on the well being, health and productivity of the occupants in a building is an important issue nowadays. Many studies have related the advantages of UFAD systems in removing indoor air contaminants from the ambient as compared to overhead systems. In the building certification systems, they figure as good alternatives to promote better indoor air quality and thermal comfort, preserving energy efficiency, which corresponds to additional points. With the expanding interest in this technology, studies that enhance its project, keeping as a goal its global efficiency, are very welcome. The aim is to experimentally verify the contribution of an UFAD system to the indoor air quality of a classroom used by 48 students at the Civil Construction Department of the Engineering School of the University of São Paulo Brazil. The study has been conducted in a non-steady state condition. In order to perform this evaluation, the levels of indoor air-borne particles were measured at the breathing zone for seated people (1.10m from the ground), and at the exhaust (2.60m from the ground) simultaneously, under six different pre-defined values of air temperature at the occupied zone (0.60m from the ground). These concentration levels have allowed calculating the contaminant removal effectiveness index, CRE, in many points of the ambient. A similar analysis was developed for the concentrations of CO2 in the second part of the experiment. At the same time, the air temperature and air velocity were measured in six different levels and at fourteen points of the ambient. The low concentration levels of total suspension particle (under 0.035 mg/m³) have shown that this system doesn\'t disperse air contaminants indoors. The CRE indexes near or above 1.0, for both total suspension particle and CO2, have confirmed the ventilation effectiveness of this underfloor air distribution system under all the operational conditions.
3

Indoor air quality, thermal comfort and damages assessment of four buildings in Athens

Stouras, Orfeas January 2020 (has links)
Nowadays individuals spend more than 85% of their total time in indoor environments, mainly at home and work. Thereby, the quality of the indoor environment plays a substantial role in human health and wellness. The four basic factors that define the perception of the indoor environment, through the senses, are the thermal comfort, the indoor air quality, the acoustical quality and the visual or lighting quality. A standard level of the above factors is ensured by the building envelope and the services systems. At the same time, the bearing structure provides the necessary resistance and durability to the construction in order to sustain the various loads without breaking down. Inevitably, over the years, all structures’ robustness declines and their functionality state degrades. For that reason, intensive provision should be given to assure the users’ safety and well-being. The objective of this study is to assess the current indoor air quality, the thermal comfort and the damages at four publicly owned buildings located in Athens, Greece. The evaluation was done through the facilities management contribution, a questionnaire survey and a technical visit – inspection where measurements were taken. Special focus was also put on the Sick Building Syndrome (SBS) and its effects. The results indicated that at 3 out of 4 buildings mainly suffer from unpleasant odors and lack of fresh air intake. Therefore, the installation of mechanical ventilation systems (air handling units, outdoor air processing units) combined with an effective air distribution system (confluent jet ventilation system) is suggested. Substantial building damages were detected at the cultural center (floorings, door/window openings, fungi) and specific proposals for restoration are made. Despite the existence of indicators of an unhealthy indoor environment, a direct correlation between the exposure to various pollutants and the SBS symptoms, cannot be established. The optimization of the research methodologies and the institution of new building design protocols is essential in order to overcome the SBS effects. On the whole, the questionnaire achieved to fulfil the objectives of the survey. It was comprehensible by the respondents while the outcome of the questionnaire and the inspection were consistent to each other. The questionnaire and the checklists are practical tools that could be used as a guide for future investigation in similar fields. Except for technical surveys and questionnaires, many suggestions for future maintenance of the buildings are provided aiming to retain their functionality. These proposals concern the services systems, the building envelope as well as the bearing structure of the buildings.
4

A Ventilation Strategy Based on Confluent Jets : An Experimental and Numerical Study

Janbakhsh, Setareh January 2015 (has links)
This study presents air distribution systems that are based on confluent jets; this system can be of interest for the establishment of indoor environments, to fulfill the goals of indoor climate and energy-efficient usage. The main objective of this study is to provide deeper understanding of the flow field development of a supply device that is designed based on wall confluent jets and to investigate the ventilation performance by experimental and numerical methods. In this study, the supply device can be described as an array of round jets on a flat surface attached to a side wall. Multiple round jets that issue from supply device apertures are combined at a certain distance downstream from the device and behave as a united jet or so-called confluent jets. Multiple round jets that are generated from the supply device move downward and are attached to the wall at the primary region, due to the Coanda effect, and then they become wall confluent jets until the floor wall is reached. A wall jet in a secondary region is formed along the floor after the stagnation region. The characteristics of the flow field and the ventilation performance of conventional wall confluent jets and modified wall confluent jets supply devices are investigated experimentally in an office test room. The study of the modified wall confluent jets is intended to improve the efficiency of the conventional one while maintaining acceptable thermal comfort in an office environment. The results show that the modified wall confluent jets supply device can provide acceptable thermal comfort for the occupant with lower airflow rate compared to the conventional wall confluent jets supply device. Numerical predictions using three turbulence models (renormalization group (RNG k– ε), realizable (Re k– ε), and shear stress transport (SST k– ω) are evaluated by measurement results. The computational box and nozzle plate models are used to model the inlet boundary conditions of the nozzle device. In the isothermal study, the wall confluent jets in the primary region and the wall jet in the secondary region, when predicted by the three turbulence models, are in good agreement with the measurements. The non-isothermal validation studies show that the SST k– ω model is slightly better at predicting the wall confluent jets than the other two models. The SST k– ω model is used to investigate the effects of the nozzle diameter, number of nozzles, nozzle array configuration, and inlet discharge height on the ventilation performance of the proposed wall confluent jets supply device. The nozzle diameter and number of nozzles play important roles in determining the airflow pattern, temperature field, and draught distribution. Increased temperature stratification and less draught distribution are achieved by increasing the nozzle diameter and number of nozzles. The supply device with smaller nozzle diameters and fewer nozzles yields rather uniform temperature distribution due to the dominant effect of mixing. The flow behavior is nearly independent of the inlet discharge height for the studied range. The proposed wall confluent jets supply device is compared with a mixing supply device, impinging supply device and displacement supply device. The results show that the proposed wall confluent jets supply device has the combined behavior of both mixing and stratification principles. The proposed wall confluent jets supply device provides better overall ventilation performance than the mixing and displacement supply devices used in this study. This study covers also another application of confluent jets that is based on impinging technology. The supply device under consideration has an array of round jets on a curve. Multiple jets issue from the supply device aperture, in which the supply device is positioned vertically and the jets are directed against a target wall. The flow behavior and ventilation performance of the impinging confluent jets supply device is studied experimentally in an industrial premise. The results show that the impinging confluent jets supply device maintains acceptable thermal comfort in the occupied zone by creating well-distributed airflow during cold and hot seasons.
5

Numerical and experimental study of confluent jets supply device with variable airflow

Andersson, Harald January 2019 (has links)
In recent years, application of confluent jets for design of ventilation supply devices has been studied. Similarly, numerus studies have been made on the potential and application of variable air volume (VAV) in order to reduce the energy demand of ventilation systems. This study investigates the combination of supply devices based on confluent jets and VAV, both in terms of the nearfield flow behavior of the device and the impact on thermal comfort, indoor air quality and energy efficiency on a classroom-level space when the airflow rate is varied. The method used in this study is an experimental field study where the confluent jets-based supply devices were compared to the previously installed displacement ventilation. The field study evaluated the energy efficiency, thermal comfort and indoor air quality of the two systems. In the case of the confluent jets supply devices, airflow rate was varied in order to see what impact the variation had on the performance of the system for each airflow rate. Furthermore, the confluent jets supply devices were investigated both experimentally and numerically in a well insulated test room to get high resolution data on the particular flow characteristics for this type of supply device when the airflow rate is varied. The results from the field study show nearly uniform distribution of the local mean age of air in the occupied zone, even in the cases of relatively low airflow rates. The airflow rates have no significant effect on the degree of mixing. The thermal comfort in the classroom was increased when the airflow rate was adapted to the heat load compared to the displacement system. The results lead to the conclusion that the combination of supply devices based on confluent jets can reduce energy usage in the school while maintaining indoor air quality and increasing the thermal comfort in the occupied zone. The results from the experimental and numerical study show that the flow pattern and velocity in each nozzle is directly dependent on the total airflow rate. However, the flow pattern does not vary between the three different airflow rates. The numerical investigation shows that velocity profiles for each nozzle have the same pattern regardless of the airflow rate, but the magnitude of the velocity profile increases as the airflow increases. Thus, a supply device of this kind could be used for variable air volume and produce confluent jets for different airflow rates. The results from both studies show that the airflow rate does not affect the distribution of the airflow on both near-field and room level. The distribution of air is nearly uniform in the case of the near-field results and the room-level measurement shows a completely uniform degree of mixing and air quality in the occupied zone for each airflow rate. This means that there is potential for combining these two schemes for designing air distribution systems with high energy efficiency and high thermal comfort and indoor air quality. / Under senare tid har applikation av Confluent jets för design av tilluftsdon studerats. Många studier har även utförts över potentialen av att applicera variabelt luftflöde (VAV) för att minska energianvändningen i ventilationssystem. Denna studie undersöker möjligheten att kombinera Confluent jets-don med VAV, både med avseende på den lokala flödesbilden och dess påverkan på termisk komfort, luftkvalitet och energieffektivitet i en klassrumsmiljö där luftflödes varieras. Denna studie baseras dels på en experimentell fältstudie där tilluftsdon baserade på Confluents jets jämfördes med befintliga deplacerande tilluftsdon. Fältstudien utvärderade energieffektiviteten, den termiska komforten och luftkvaliteten för båda typerna av tillluftsdon. Confluent jets-donen testades under varierat luftflöde för att se påverkan av flödesvariationen på ventilationens prestation under de olika flödena. Utöver fältstudien testades Confluent jets-donen experimentellt och numeriskt i ett välisolerat test-rum för få den detaljerade flödeskarakteristiken för den här typen tilluftsdon vid varierat luftflöde. Resultaten från fältstudien visar på en jämn fördelning av den lokala luftsmedelåldern i vistelsezonen, även för fallen med relativt låga luftflöden. Luftflöden har ingen signifikant effekt på omblandningen. Den termiska komforten i klassrummet ökade när luftflödet anpassades efter värmelasten jämfört med de deplacerande donen. Slutsatsen från fältstudien är att kombinationen av VAV och Confluent jets-don kan användas för att minska energianvändningen på skolan och bevara luftkvaliteten och den termiska komforten i vistelsezonen. Resultaten från den experimental och numeriska studien visar luftflödet och lufthastigheten i varje enskild dysa är direkt beroende på det totala luftflödet genom donet. Dock är flödesfördelningen mellan dysorna oberoende av de tre olika luftflödena. Den numeriska undersökningen visar att flödesprofilen för varje dysa är konstant trots att flödet varieras, men amplituden för varje profil ökar med en höjning av luftflödet. Det betyder att tilluftsdon av den här typen kan användas med VAV för att producera Confluent jets för olika luftflöden. Resultaten från båda studierna visar att luftflöde inte påverkar fördelningen av luften vare sig längs luftdonen eller på rumsnivå. Fördelningen av luften är nästan helt jämn längs donen och på rumsnivå är omblandningen och luftkvalitet den samma för varje luftflöde. Det betyder att det finns potential för att kombinera det här två teknikerna för att designa luftdistribueringssystem med hög energieffektivitet och hög termisk komfort med god luftkvalitet.

Page generated in 0.1361 seconds