• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 28
  • 14
  • Tagged with
  • 42
  • 42
  • 29
  • 27
  • 27
  • 15
  • 14
  • 10
  • 9
  • 9
  • 9
  • 8
  • 8
  • 8
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Förbättrat inomhusklimat med lägre energiförbrukning i öppet kontorslandskap : Ventilationens påverkan på inomhusklimatet och termisk komfort

Christopher, Magnusson January 2019 (has links)
Idag spenderas en stor del av vår tid inomhus, det ställer krav på inomhusluften.  Koldioxid och andra föroreningar, som stannar i luften vid dåligt ventilerade  lokaler, påverkar negativt och är bevisat att påverka prestationen och produktiviteten  hos människor i specifika uppgifter. Idag läggs mycket fokus på miljösmarta  lösningar och effektiviseringar, men ibland glöms inomhusklimatet bort. För att  människor ska få en behaglig upplevelse av inomhusklimatet krävs  kvalité på inomhusluften men också på den termiska komforten. Huvudsyftet med examensarbetet är att förklara hur det går att uppnå  förbättrat inomhusklimat och samtidigt minska energiförbrukningen. Genom att minska energibehovet kan företag bli mer konkurrenskraftiga och samtidigt rusta sig mot de stigande elpriserna. Det finns även en ekonomisk fördel för företag såväl som för privata bostäder. Examensarbetet består utav en fallstudie, där luftenstemperatur och fuktighet kommer at loggas och data genereras. Loggning kommer att  ske vid två tillfällen. Först i början för att få en uppfattning om varför  personalen upplever dåligt inomhusklimat och sedan efter justering av luftflödena  för att se skillnaden i förändringen av inomhusklimatet och energipåverkan.   Genom att justera systemet och sammanställa resultat har forskningsfrågan ”Kan inomhusklimatet förbättras samtidigt och samtidigt minska energiförbrukningen?”  besvarats. Litteraturstudien visar att om alternativa ventilationsprinciper  används, istället för det konventionella omblandande systemet, går det att minska  energiförbrukningen samtidigt som inomhusklimatet förbättras. Detta har gjorts  genom att golvventilation använts där tilluften tillförts lågt och undertempererad för att luften ska stiga genom de termiska krafterna. Resultatet visar att termisk komfort försämrats enligt enkätstudierna, men samtidigt visar det en förbättring av  inneklimatet i enskilda frågor. Mätresultaten indikerar även på förbättrad  ventilation och inomhusklimat. Slutligen presenterades energibesparingsåtgärder som företaget kan göra för att minska energibehovet och samtidigt förbättra den termiska komforten.
2

Radiatorsystem eller golvvärmesystem? : En ekonomisk och termisk jämförelse mellan två vattenburna värmesystem / Radiator system or underfloor heating?

Gustafsson, Molly, Ericson, Martin January 2020 (has links)
The objective is to produce a recommendation for Bonava's future constructions regarding heating systems and installation methods. The report consists of a comparison between radiator system and underfloor heating by looking at the installation costs and the thermal comfort. It consists of a quantitative survey with measuring instruments to find out variations in the indoor temperature. The content can be used as guidelines for construction planning for apartment buildings to see which system that is most suitable for the cause. Based on the result, it can be concluded that the radiator system is cheaper to install than an underfloor heating system. The radiator system provides a more even indoor temperature. Radiator systems can therefore be said to be better from the thermal comfort aspect. Our technical examination and calculations indicate that the radiator system is cheaper and better seen for thermal comfort. Our recommendation to Bonava is therefore to choose this system. We also found through the index that it was a smaller difference between installation costs for the systems the larger the apartment area was. In terms of price, the difference between the heating systems is small when you consider the life-span of the systems. Installation costs do not therefore have to be decisive, but other factors may need to be taken into account in the choice of system.
3

Förbättringsåtgärder för termisk komfort i ett 70-tals lamellhus i Gävle

Noori, Massoud, Eriksson, Alexander Patrik January 2022 (has links)
In 1964, the then Swedish government decided that one million new homes would be erected within a decade to tackle the then housing shortage. This decision was characterized as the “million program”. Just over five decades later, many of the million program's buildings needrenovation. After many years of use, structural engineering measures are required to satisfytoday's standards regarding thermal comfort. One or more deficiencies mentioned about the buildings of the million programs can have a direct or indirect impact on the thermal comfort. Poor or excessive ventilation, windows that are leaky or have high heat permeability and poor insulation are factors that can adversely affect thermal comfort. Thermal comfort is a key issue today as it affects us all. According to The Public Health Agency of Sweden, thermal comfort can have several different effects on our health, where too high temperature can result in headaches, nausea, and fatigue, while too cold indoor climate can lead to more dramatic health effects such as lung-related diseases, vascular diseases and affected blood pressure. We Swedes spend about 90 % of our lives indoors.In this case study, a two-story slat was examined on Regnbågsgatan in Gävle with the aim of identifying deficiencies and developing a model in IDA-ICE and then investigating various improvement measures. Data to produce the model was collected through an ocular inspection with IR thermography for identification of thermal bridges, drawings, user data from Sveby and data from the Gavlegårdarna which were then supplemented with a literature study. The model was created with four different programs: Revit, where a basic geometric model was created, Simplebim for validation of model before IDA-ICE, COMSOL Multiphysics for modeling thermal bridges and finally IDA-ICE for energy and climate simulations.Potential improvement measures were discovered through literature study and analysis of deficiencies that could be identified in simulation of current cases for the slat building. The measures were carried out by changing different input data for the different components of the slat housing in the IDA-ICE program. A survey study was conducted to investigate how users experienced the thermal climate; however, the outcome of this study did not lead to anything as there were too few respondents.Deficiencies that could be detected during the first simulation were that rooms located at the gables had poor thermal comfort because the gables were not sufficiently insulated. Rooms with the worst thermal comfort could be identified at the northern end and a trend that floor 2 had poorer thermal comfort compared to floor 1. A combination of additional insulation of the gables, replacement of windows and balcony doors to those with a lower U-value, as well as a temperature-controlled FTX system had the best effect on thermal comfort. After this action, the building meets the requirement for bronze in terms of the thermal climate summer and winter according to Sweden Green Building Council.
4

Utvärdering av innemiljön på Vargbroskolan / Evaluation of the indoor environment in Vargbroskolan

Månsson, Sanna, Gustafson, Micaela January 2009 (has links)
<p>Nya Vargbroskolan stod klar januari 2008. Det är en skola unik i sitt slag då fokus under hela projekteringen har legat på energieffektivisering och låg miljöpåverkan. Resultatet blev en superisolerad byggnad med ett hybridventilationssystem med kulvert som värmer luften innan den går in i byggnaden på vintern och kyler på sommaren. För att se hur skolan fungerar i praktiken pågår en utredning där innemiljön och energiåtgången utvärderas.</p><p> </p><p>I den här rapporten behandlas den termiska komforten, luftkvaliteten och ljudmiljön på Vargbroskolan. Ljudmiljön är avgränsad till installationsbuller som orsakas av ventilationssystemet. När det gäller luftkvaliteten är den inriktad på koldioxid och luftburna partiklar. Den termiska komforten beror av fyra faktorer, temperatur, värmeinstrålning, luftrörelser och relativ fuktighet.</p><p> </p><p>Bullermätningar för att mäta den ljudnivå som är orsakad av ventilationssystemet är gjorda enligt SS-EN ISO 16032:2004. Dessa resultat är sedan jämförda med vad de svenska normerna säger. I sex olika klassrum har koldioxidhalt, temperatur och relativ fuktighet mätts med en integrerande mätanordning. För samma klassrum har närvarostatistik förts under två veckor i februari och på så sätt har mätdata och antalet personer kunnat jämföras för att hitta något samband. Partikelmätning har genomförts med hjälp en partikelräknare, Climet CI-500, för att kunna utvärdera kulvertens sedimentationsförmåga när det gäller luftburna partiklar.</p><p>Förutom olika mätningar har också en enkätundersökning gjorts. Det är skolpersonalen som svarat och enkäten är en MM 040 NA, vilket är en standard enkät av Örebromodellen.</p><p> </p><p>Slutsatserna är att bullernivån från ventilationssystemet på Vargbroskolan ligger väldigt nära och ibland lite över normvärdena, vid maximalt flöde. Skolpersonalen tycker inte, enligt enkätundersökningen som gjorts, att detta buller är något störande. Koldioxidhalten ligger lite högt under vissa perioder men verkar inte påverka upplevelsen av inneklimatet negativt. Den termiska komforten är inte särskilt bra på Vargbroskolan, även om den är bättre än på referensskolor enligt enkäten. Sämst är det då det gäller temperaturen. Även om det är kallt uppfattas inte miljön som dragig mer än ibland. Den relativa luftfuktigheten ligger för lågt periodvis, men inte så lågt att det skulle ge fysiska besvär för människorna som vistas i lokalerna. Dock får det ju ses som positivt att en konstant temperatur går att hålla med hjälp av det temperaturstyrda ventilationssystemet.  Detta visar att systemet fungerar bra och som det ska.</p> / <p>In January 2008, the new Vargbroskolan was ready to be used. It is a school unique in its kind because the entire design has been focused on energy efficiency improvement and low environmental impact. The result became a very high isolated building with a hybrid ventilation system. The building has a culvert which heats the air before it gets in to the building in the winter and cools it in the summer. In order to see how the school functions in reality, an investigation where the indoor environment and the energy consumption are evaluated.</p><p> </p><p>In this report, the thermal comfort, the air quality and the sound environment in Vargbroskolan is treated. The sound environment is delimited to the noise caused by the ventilation system. When it comes to the air quality, focus is lying on carbon dioxide and airborne particles. The thermal comfort depends of four factors, temperature, thermal radiation, air movements and relative humidity.</p><p> </p><p>To measure the sound level caused by the ventilation system measurements has been done according to SS-EN ISO 16032:2004. These results are then compared to the Swedish standards. In six different classrooms the carbon dioxide, temperature and relative humidity has been measured with an integrating measuring instrument. For the same classrooms presence statistic has been pursued during two weeks in February. In this way data and the number of persons can be compared in order to find some connections. Particle measurement has been implemented with help of a particle counter, Climet CI-500, in order to evaluate the sedimentation ability of the culvert when it comes to airborne particles. Apart from different measurements an inquiry has also been done. The inquiry is of the kind MM 040 NA which is a standard questionnaire of Örebromodellen and it is the staff on Vargbroskolan who has replied.</p><p> </p><p>The conclusions are that the noise level caused by the ventilation systemet lies near and sometimes a little bit over the standard values, during maximum flow. The staff on Vargbroskolan does not think that this noise is disturbing, according to the inquiry. The concentration of carbon dioxide is a little bit to high during some periods but does not seem to influence the experience of the indoor environment negative either. The thermal comfort is not particularly good in Vargbroskolan, although it is better than the thermal comfort in reference schools according to the inquiry. The temperature is the factor most people complains about, but even though it is cold, the environment does not seem draughty more than sometimes. The relative humidity lies to low periodically, but not so low that it would give physical inconveniences for the people in the classroom. However, the system holds a constant temperature which is positive and it also shows that the system is working correctly.</p>
5

Utvärdering av innemiljön på Vargbroskolan / Evaluation of the indoor environment in Vargbroskolan

Månsson, Sanna, Gustafson, Micaela January 2009 (has links)
Nya Vargbroskolan stod klar januari 2008. Det är en skola unik i sitt slag då fokus under hela projekteringen har legat på energieffektivisering och låg miljöpåverkan. Resultatet blev en superisolerad byggnad med ett hybridventilationssystem med kulvert som värmer luften innan den går in i byggnaden på vintern och kyler på sommaren. För att se hur skolan fungerar i praktiken pågår en utredning där innemiljön och energiåtgången utvärderas.   I den här rapporten behandlas den termiska komforten, luftkvaliteten och ljudmiljön på Vargbroskolan. Ljudmiljön är avgränsad till installationsbuller som orsakas av ventilationssystemet. När det gäller luftkvaliteten är den inriktad på koldioxid och luftburna partiklar. Den termiska komforten beror av fyra faktorer, temperatur, värmeinstrålning, luftrörelser och relativ fuktighet.   Bullermätningar för att mäta den ljudnivå som är orsakad av ventilationssystemet är gjorda enligt SS-EN ISO 16032:2004. Dessa resultat är sedan jämförda med vad de svenska normerna säger. I sex olika klassrum har koldioxidhalt, temperatur och relativ fuktighet mätts med en integrerande mätanordning. För samma klassrum har närvarostatistik förts under två veckor i februari och på så sätt har mätdata och antalet personer kunnat jämföras för att hitta något samband. Partikelmätning har genomförts med hjälp en partikelräknare, Climet CI-500, för att kunna utvärdera kulvertens sedimentationsförmåga när det gäller luftburna partiklar. Förutom olika mätningar har också en enkätundersökning gjorts. Det är skolpersonalen som svarat och enkäten är en MM 040 NA, vilket är en standard enkät av Örebromodellen.   Slutsatserna är att bullernivån från ventilationssystemet på Vargbroskolan ligger väldigt nära och ibland lite över normvärdena, vid maximalt flöde. Skolpersonalen tycker inte, enligt enkätundersökningen som gjorts, att detta buller är något störande. Koldioxidhalten ligger lite högt under vissa perioder men verkar inte påverka upplevelsen av inneklimatet negativt. Den termiska komforten är inte särskilt bra på Vargbroskolan, även om den är bättre än på referensskolor enligt enkäten. Sämst är det då det gäller temperaturen. Även om det är kallt uppfattas inte miljön som dragig mer än ibland. Den relativa luftfuktigheten ligger för lågt periodvis, men inte så lågt att det skulle ge fysiska besvär för människorna som vistas i lokalerna. Dock får det ju ses som positivt att en konstant temperatur går att hålla med hjälp av det temperaturstyrda ventilationssystemet.  Detta visar att systemet fungerar bra och som det ska. / In January 2008, the new Vargbroskolan was ready to be used. It is a school unique in its kind because the entire design has been focused on energy efficiency improvement and low environmental impact. The result became a very high isolated building with a hybrid ventilation system. The building has a culvert which heats the air before it gets in to the building in the winter and cools it in the summer. In order to see how the school functions in reality, an investigation where the indoor environment and the energy consumption are evaluated.   In this report, the thermal comfort, the air quality and the sound environment in Vargbroskolan is treated. The sound environment is delimited to the noise caused by the ventilation system. When it comes to the air quality, focus is lying on carbon dioxide and airborne particles. The thermal comfort depends of four factors, temperature, thermal radiation, air movements and relative humidity.   To measure the sound level caused by the ventilation system measurements has been done according to SS-EN ISO 16032:2004. These results are then compared to the Swedish standards. In six different classrooms the carbon dioxide, temperature and relative humidity has been measured with an integrating measuring instrument. For the same classrooms presence statistic has been pursued during two weeks in February. In this way data and the number of persons can be compared in order to find some connections. Particle measurement has been implemented with help of a particle counter, Climet CI-500, in order to evaluate the sedimentation ability of the culvert when it comes to airborne particles. Apart from different measurements an inquiry has also been done. The inquiry is of the kind MM 040 NA which is a standard questionnaire of Örebromodellen and it is the staff on Vargbroskolan who has replied.   The conclusions are that the noise level caused by the ventilation systemet lies near and sometimes a little bit over the standard values, during maximum flow. The staff on Vargbroskolan does not think that this noise is disturbing, according to the inquiry. The concentration of carbon dioxide is a little bit to high during some periods but does not seem to influence the experience of the indoor environment negative either. The thermal comfort is not particularly good in Vargbroskolan, although it is better than the thermal comfort in reference schools according to the inquiry. The temperature is the factor most people complains about, but even though it is cold, the environment does not seem draughty more than sometimes. The relative humidity lies to low periodically, but not so low that it would give physical inconveniences for the people in the classroom. However, the system holds a constant temperature which is positive and it also shows that the system is working correctly.
6

Enstudie om lågtempererat värmesystem i vägg : -Fokus på inomhusklimatet och energianvändning

Johansson, Thomas, Magnusson, Tobias January 2013 (has links)
Today the human being see energy as a matter of course but the resources that is used for extract energy is today not enough for the world demand. Of all the energy that is used in Sweden today approximately 40 % goes to the building stock. This number will most likely increase if not necessary actions will be made on the already existing building stock since new houses constantly are built which will be added up on the already existing energy supply. This takes cause of action on the already existing building stocks, to fulfill the demands of the future use of energy that has been set by the authority. At the same time the thermal conditions cannot be influenced by the necessary changes that must be made. The study highlights the possibility to improve the thermal conditions and the use of energy by a built- in system with wall heating instead of traditional radiators. The authors of this rapport have focused on residences which are a part of the so called millionprogram. Today 25 % of the total amount of residences in Sweden belongs to the program and all of them are in great need of a renovation. A study was practically made in the laboratory and to confirm the data a second measurement was made in the simulation software IDA Indoor Climate and Energy.  In the laboratory two different room heaters was mounted to a wall which lied next to a cool chamber and measurements were made on the basis of the perceived comfort and power requirements. Three different effects were used for each room heater to allow the graph to indicate a possible straight line. The result was as expected a straight line for the radiator while for wall heating system did not created a clear link between the different effects. It could be seen that the power requirements were lower for wall heating than radiator since more people experienced a better climate at lower effects than 600-650 W which was the optimum effect for the radiator. It requires more measurements than what was made in this work to give a clear-cut answer on which system provides the best comfort and minimum use of energy. Even though the amount of measurements were few it is still possible to see some improvement in both instances for wall heating system. Hopefully this report arouses an interest in continued research in the field. / Energi är idag något människan ser som en självklarhet, men de resurser som används för energiutvinning klarar i nuläget inte efterfrågan. Av all energi som används i Sverige används cirka 40 % till byggnadsbeståndet, denna siffra kommer troligtvis öka om inte åtgärder görs på det befintliga byggnadsbeståndet. Dessutom byggs nya hus som ger ett påslag på den nuvarande energianvändningen.  Detta gör att energiförbättringar krävs på det befintliga beståndet för att uppnå de krav som ställs från myndigheter om framtida energianvändning. Samtidigt får inte den termiska komforten påverkas av ingreppen som krävs. Denna studie belyser om det är möjligt att förbättra den termiska komforten och sänka energianvändningen med ett värmesystem inbyggt i vägg istället för traditionella radiatorer. Studien berör bostäder som ingår i det så kallade miljonprogrammet som uppgår till 25 % av det totala svenska bostadsbeståndet och som dessutom är i stort behov av renovering.    En studie utfördes praktiskt i laboratorium samt med simulering i mjukvaran IDA Indoor Climate and Energy. I laboratoriet monterades två olika rumsvärmare på en vägg som angränsade till en kylkammare, och mätningar gjordes för att få fram den upplevda komforten samt effektbehov.  Tre olika effekter användes för varje rumsvärmare för att möjliggöra en graf för att kunna tyda en eventuell rät linje. I IDA-ICE gjordes simuleringar utifrån laboratorieförsöken. Resultatet gav som förväntat en rät linje för radiatorn, medan det för väggvärmesystemet inte skapades ett tydligt samband mellan de olika effekterna. Resultatet gav att effektbehovet var lägre för väggvärme än radiator då fler människor upplevde ett bättre klimat vid lägre effekter än 600-650 W som var den optimala effekten för radiatorn. Det krävs fler mätningar än vad som gjordes i detta arbete för att ge ett entydigt svar på vilket system som ger bäst komfort och minst energianvändning. Det går att utläsa en viss förbättring i de båda avseendena för väggvärmesystemet och förhoppningsvis väcker denna rapport ett intresse för fortsatt forskning inom området.
7

Placering av Phase Change Material i en yttervägg för minskning av köpt energi? : Fallstududie Ljusbo prototyphus

Nilsson, Marcus, Lindström, Magnus January 2018 (has links)
I dagens samhälle använder vi stora mängder energi och denna energi kommer huvudsakligen från fossila bränslen. Byggnadssektorn står för ca 40% av den totala energianvändningen och den termiska komforten har stor betydelse för hur mycket energi vi använder till byggnaden. Resultat från tidigare forskning visar att fasomvandlingsmaterial (PCM) kan lagra värme och kyla och på så sätt balansera temperaturen i en byggnad så att den termiska komforten blir bättre. Dagens samhälle är beroende av att förnybara energikällor skall börja användas för att främja en hållbar utveckling. Genom att sammankoppla PCM med solenergi skulle en hållbar energikälla kunna uppnås. Ljusbo Green Building satsar på att bli ett så kallat plushus, där man producerar mer energi än vad som görs av med. Syftet med studien var att studera om PCM kan bidra till att minska en byggnads energianvändning genom att placera ett PCM i ytterväggkonstruktion. Frågeställningen var om energibehovet minskar till byggnaden genom att inkludera PCM i en vägg enligt Ljusbos standard? Med simuleringar i COMSOL Multiphysics 5.3 utförs en fallstudie på Ljusbos prototypbyggnad för att se om ett PCM-material som placeras i en ytterväggkonstruktion kan minska energianvändningen hos byggnaden. PCM-materialet värms med varm uteluft dagtid eller soluppvärmd uteluft, så att värmen som tillförts uteluften minskar transmissionsförlusten genom ytterväggen. Resultatet visar att då PCM placeras i mitten av en yttervägg minskar värmeflödet från byggnaden under kallare perioder då uppvärmd luft tillförs i väggen. Det ger samma effekt oberoende på vilken fasförändringstemperatur som väljs på PCM:et. Studiens slutsats var att PCM kan minska värmeflödet från byggnaden under kallare perioder, men ger ingen effekt under varmare perioder.
8

Klimatförändringarnas inverkan på inneklimat och energianvändning i passivhus / The impact of climate change on indoor climate and energy use in passive houses

Nylander, Joacim, Sandström, Hugo January 2016 (has links)
Purpose: The purpose of this study is to contribute with knowledge about how the warming effects of climate change may affect indoor living standards, considering that we are already living with some over-temperatures during the summer time. The specific aim is therefore to show how thermal climate in warm passive houses will be perceived, and how specific energy consumption will be affected, within the near future in southern Sweden. Method: To order to achieve the aim, a specific scenario of future temperatures had to be defined. Official climate data for the year 2050 in Gothenburg was collected and compiled. A certified passive house was theoretically exposed to the expected future climate and indoor temperature as well as energy consumption was calculated. Calculations were made using the energy calculation software BV2 for reference conditions and adaptions of both climate as well as technical solutions for greater thermal comfort. Findings: A climate scenario for Gothenburg during year 2050 illustrates that the average year-temperature increases from +7.7°C to +9.9°C. The largest change can be observed during the winter, with an increase peaking at +2.5 ºC. The results show an increase from 65 to 107 number of days during the year in which the studied passive house has an inadequate indoor temperature, as a consequence of over-temperatures. One method for thermal climate enhancing, using a combination of sun screening and air conditioning powered by solar cells, showed having good impact without considerably affecting the specific energy consumption. Implications: In a passive house without air conditioning, the thermal indoor climate will reach an unacceptable level for the tenants, more often in the year 2050, than during the reference period, due to warmer outside temperatures. The method which has the smallest impact upon the energy consumption is sun screening, while air conditioning is the most effective, but also very energy consuming. In order to optimally conserve the thermal indoor climate without decreasing the free energy during the winter, one should install both sun screening and air conditioning in their passive house. Limitations: The result is applicable on passive houses within climate zone III, but the general conclusions made applies for all passive houses in Sweden. Using different methods of calculating the indoor temperature may result in variable results. Keywords: Climate change, Passive house, Indoor climate, Thermal comfort, Energy consumption
9

Jämförelse av VAV- och CAV-ventilationssystem för nybyggd skola och dess känslighet för ökad personbelastning : En simuleringsstudie med IDA ICE

Hansson, Kajsa January 2019 (has links)
Att minska energianvändningen är lika mycket ett globalt mål som ett nationellt mål. Sverige har som mål att öka effektiviseringen av energianvändningen med 20 % fram till år 2020. Det gör att nästan alla sektorer påverkas och inte minst bostads- och servicesektorn som står för nästan 40 % av Sveriges energianvändning. Ventilationssystem är en av de saker som kan bidra till energibesparingen. I den här studien har en nybyggd grundskola simulerats avseende energi och komfort där olika ventilationssystem testats för att se vilket system som är mest lönsamt ekonomiskt, energi- och komfortmässigt. Det som skiljer ventilationssystemen åt är de olika typerna av flödesreglering. Två huvudtyper av ventilationsflödesreglering har testats: ”Variable Air Volume” = Luftflödet varierar efter behovet (VAV) och ”Constant Air Volume” = Konstant luftflöde (CAV). Byggnaden, som är välisolerad och har tung stomme, har även simulerats med ökad personbelastning för att se hur det påverkar ventilationssystemet. Metoden som används för att utföra arbetet är en simuleringsstudie av komparativt slag, där datorprogrammet IDA ICE 4.8 har använts för att modellera byggnaden och utföra simuleringarna. Modellen som har simulerats efterliknar delar av grundskolan Stigslundsskolan i Gävle, i både uppbyggnad, ventilation och användningsgrad. Data har samlats in från konsultföretaget Rambolls databaser med information om projekteringen av skolan och genom personlig kommunikation. Simuleringen av ett skolår har utförts och ett schema för personbelastningen har ställts in för varje sal för att efterlikna det schema som eleverna går efter i dagsläget. Resultatet av simuleringarna visade att VAV -ventilationssystemet som efterliknar det projekterade fallet väl täckte ventilationsbehovet, använde mindre energi än CAV-systemet och skapade ett mycket bra termiskt klimat i byggnaden. Resultatet visade också att ökad personbelastning hade stor inverkan på ventilationssystemet, och medförde bland annat att återbetalningstiden för VAV-systemet ökade från 11 till 30 år. / To reduce the energy use is as much a global goal as it is an international goal. The Swedish goal is to increase the efficiency of energy use with 20 % by year 2020. This means that almost all the sectors are affected, that includes the housing and service sector which accounts for almost 40 % of Sweden’s energy use. The ventilation system is one thing that can contribute to saving energy. In this study a new built primary school has been simulated, regarding energy use and thermal comfort, where different ventilation system has been tested to determine which system are the most profitable in economically, energy and comfortably. The ventilation system different in the flow control. Two main types of flow control have been tested: Variable Air Volume (VAV) and Constant Air Volume (CAV). The building, which is well insulated and has a heavy body has also been simulated with increased personal load to see how it affects the ventilation system. The method used to perform the work is a comparative type simulation study. The computer program IDA ICE 4.8 has been used to build the model and do the simulations. The model that has been simulated resemble the primary school Stigslundsskolan in Gävle in both construction, ventilation and degree of use. Data has been collected from the consulting company Ramboll’s database with information on the planning of the school. Personal communication has also been used to collect information. The simulations have been performed for a school year and a schedule for the personal load has been set for each hall to imitate the schedule that the students are following today. The result of the simulations showed that the VAV ventilation system, which resemble the planned case, cover the ventilation requirements, uses less energy than the CAV system and create a very good thermal climate in the building. The result also shows that the increased personal load had a great influence on the VAV ventilation system and increased the repayment period from 11 to 30 years.
10

Dynamic use of the building structure - energy performance and thermal environment

Høseggen, Rasmus Z January 2008 (has links)
<p>The main objectives of this thesis have been to evaluate how, under which premises, and to what extent building thermal mass can contribute to reduce the net energy demand in office buildings. The thesis also assesses the potential thermal environmental benefits of utilizing thermal mass in office buildings, i.e. reduction of temperature peaks, reduction of temperature swings, and the reduction in the number of hours with excessive operative temperatures. This has been done by literature searches, and experimental and analytical assessments. This thesis mainly concerns office buildings in the Norwegian climate. However, the methods used and the results obtained from this work are transferable to other countries with similar climates and building codes.</p><p>Within the limitations of this thesis and based on the findings from all parts and papers this thesis comprises, it is shown that utilization of thermal mass in office buildings reduces the daytime peak temperature, reduces the diurnal temperature swing, decreases the number of hours with excessive temperatures, and increases the ability of a space to handle daytime heat loads. Exposed thermal mass also contributes to decrease the net cooling demand in buildings. However, thermal mass is found to have only a minor influence on the heating demand in office buildings.</p><p>The quantity of the achievements is dependent on the amount of exposed thermal mass, night ventilation strategy, and airflow rates. In addition, parameters such as set point temperatures, control ranges, occupancy patterns, daytime ventilation airflow rates, and prevailing convection regimes are influential for the achieved result. The importance of these parameters are quantified and discussed.</p> / <p>Hovedmålene med denne avhandlingen har vært å evaluere hvordan, under hvilke forutsetninger og i hvilken utstrekning termisk masse kan bidra til å redusere netto energibehov i kontorbygninger. Avhandlingen vurderer også hvilke potensielle fordeler termisk masse har for det termiske inneklimaet, dvs. reduksjon av maksimumstemperatur, temperatursvingninger og antall timer med overtemperaturer. Disse undersøkelsene er gjort gjennom søk i litteraturen, feltstudier og analytiske metoder. Avhandlingen omfatter i hovedsak kontorbygninger under norske forhold, men metodene og resultatene er overførbare til andre land med sammenlignbare klimatiske forhold og byggeskikk.</p><p>Innenfor avgrensningene gjort i avhandlingen og basert funnene i de ulike delene og artiklene avhandlingen består av, er det vist at utnyttelse av termisk masse i kontorbygg bidrar til å redusere netto energibehov. Termisk masse reduserer også maksimumstemperaturen dagtid, demper temperaturvariasjonene over døgnet og reduserer antall timer med overtemperaturer. Utnyttelse av termisk masse bidrar også til at rom kan tåle en høyere intern varmelast enn lette rom uten at dette går ut over den termiske komforten. Termisk masse har imidlertid liten betydning for energibehovet for oppvarming i kontorbygg.</p><p>Gevinsten med å utnytte termisk masse avhenger av tilgjengeligheten av eksponerte tunge materialer, strategi for nattventilasjon og ventilasjonsluftmengder. I tillegg innvirker parametere som settpunkttemperaturer, dødbånd og kontrollintervaller for ventilasjonen og bruksmønster. Innvirkningen av disse parametrene er diskutert og kvantifisert.</p>

Page generated in 0.0796 seconds