• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 15
  • 3
  • 1
  • 1
  • Tagged with
  • 21
  • 21
  • 12
  • 12
  • 7
  • 7
  • 7
  • 6
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Análise quantitativa das partículas de óxido de alumínio geradas na abrasão a ar em consultório odontológico

Scannavino, Fábio Luiz Ferreira [UNESP] 18 February 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:48Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-02-18Bitstream added on 2014-06-13T20:56:50Z : No. of bitstreams: 1 scannavino_flf_me_arafo.pdf: 459200 bytes, checksum: 7da03a73587b35e389935c5420bccdb6 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O sistema de abrasão a ar funciona por meio de energia cinética produzida por um jato pressurizado de partículas de óxido de alumínio, que tem a finalidade de abrasionar a superfície dentária. O objetivo deste estudo foi avaliar a efetividade do sistema de sucção, disponível em consultório odontológico, na captação das partículas de óxido de alumínio emitidas pelo aparelho de abrasão a ar. Um dispositivo metálico, que reproduzia as posições e as distâncias de trabalho do cirurgião-dentista, foi elaborado para a deposição das partículas de óxido de alumínio presentes no campo operatório durante a utilização do sistema de abrasão a ar. Para a aspiração do pó de óxido de alumínio foram empregadas as sucções de alta potência e odontológica convencional com sugadores convencional e modificado por funil. A quantificação das partículas foi obtida pela massa de óxido de alumínio depositada após a aplicação do aparelho de abrasão a ar. Os resultados obtidos pela estatística descritiva gráfica revelaram que a maior deposição das partículas ocorreu a 20 cm do centro da cavidade bucal e na posição de trabalho 9 horas, quando se utilizou o sugador convencional em alta potência de sucção. / The air abrasion system works using kinetic energy produced by pressurized air with aluminum oxide particles resulting in abrasion of the dental surface. The aim of this study was to compare the efficacy of high-volume evacuation (HVE) and conventional dental suction (CDS) in aluminum oxide particles evacuation. A metallic device was elaborated to reproduce the dentist operatory positions and to aluminum oxide particles deposition. The dust collection was made by conventional saliva ejector and modified ejector by funnel-shaped. The amount of particles showed that the greatest abrasive particles deposition occurred at the 20cm of distance from the center of the mouth at 9 o'clock operatory position with the conventional saliva ejector attached to high-volume evacuation (HVE).
12

Avaliação da superfície do esmalte após diferentes tempos de jateamento de óxido de alumínio indicados para a colagem de braquetes / Evaluation of enamel surface after different times of aluminium oxide sandblasting indicated for bracket bonding

Lilian Rocha Gabarrone 01 July 2016 (has links)
Objetivo: avaliar e comparar os efeitos do jato de óxido de alumínio sobre a superfície do esmalte, quando aplicados por tempos diferentes. Material e métodos: 110 pré-molares foram obtidos por meio de doações do Banco de Dentes da FOUSP. Os dentes foram divididos aleatoriamente em 5 grupos (n=22) para a aplicação de jato de óxido de alumínio por diferentes períodos de tempo. Nos grupos A, B, C, D e E o jato de óxido de alumínio de 50 ?m foi aplicado, respectivamente, por 01, 03, 05, 07 e 10 segundos. Avaliações quantitativas da superfície do esmalte foram realizadas pelas análises das alterações do perfil e da rugosidade (Sa) da superfície vestibular antes e após o seu jateamento, por meio do medidor de perfil Form Talysurf Intra (Taylor Hobson - AMETEK Inc, Pennsylvania) e do interferômetro a laser Talysurf CCl Lite (Taylor Hobson - AMETEK Inc, Pennsylvania), respectivamente. Uma avaliação qualitativa da superfície do esmalte foi realizada por meio da microscopia eletrônica de varredura (MEV). Para esta última análise, um exemplar de cada grupo foi selecionado aleatoriamente para que as superfícies de esmalte jateadas fossem devidamente preparadas para as suas leituras. Os dados quantitativos foram comparados pelo teste ANOVA, seguido do teste post hoc de Tukey, adotando-se um nível de significância de 5% (p= 0,05). Resultados: observou-se maior alteração do perfil e da rugosidade conforme se aumentou o tempo de aplicação do jato de óxido de alumínio. Porém, com relação à alteração do perfil, diferenças estatisticamente significantes foram observadas somente entre o grupo A (1s) quando comparado aos grupos D (7s) e E (10s), e entre o grupo B (3s) quando comparado com o grupo E (10s). Quanto à rugosidade, verificou-se diferença estatisticamente significante apenas entre o grupo E (10s) quando comparado aos demais grupos. As cinco imagens obtidas pelo microscópio eletrônico de varredura (MEV) demonstraram bastante semelhança entre si, com padrão de condicionamento marcado por picos e vales, porém as imagens dos esmaltes jateados por 1 e 3 segundos apresentaram esses picos e vales em menor quantidade. Conclusão: a perda de estrutura dentária e a rugosidade da superfície do esmalte aumentaram conforme se aumentou o tempo de aplicação do jato de óxido de alumínio; a aplicação do jato de óxido de alumínio por 1 e 3 segundos promove menos perda de estrutura de esmalte do que quando se jateia o esmalte por 10 segundos; maior rugosidade pode ser obtida com o jateamento de óxido de alumínio por 10 segundos; entretanto, o aspecto morfológico do esmalte dentário é bastante similar, independentemente do tempo de jateamento. / Objective: To evaluate and compare the effects of aluminium oxide sandblasting on enamel surface when applied at different times. Materials & Methods: 110 premolars were obtained from the local tooth bank. The teeth were randomly divided into 5 groups (n = 22) for application of aluminium oxide sandblasting at different times. In Groups A, B, C, D and E, sandblasting with 50-?m aluminium oxide particles was applied for 01, 03, 05, 07 and 10 seconds, respectively. Quantitative assessments of enamel surface were performed by analysing changes in the profile and roughness (Sa) of the buccal surface before and after sandblasting application by using a profile gauge (Form Talysurf Intra, Taylor Hobson - AMETEK Inc, Pennsylvania, USA) and a laser interferometer (Talysurf CCl Lite, Taylor Hobson - AMETEK Inc, Pennsylvania, USA), respectively. A qualitative assessment of enamel surface was performed by means of scanning electron microscopy (SEM). For this latter analysis, a sample of each group was randomly chosen so that the sandblasted enamel surfaces could be adequately prepared to be evaluated. The quantitative data were compared by using ANOVA test, followed by post-hoc Tukey\'s test, at a significance level of 5% (P = 0.05). Results: Profile and roughness were found to be more altered as the sandblasting application time increased. With regard to the profile, however, statistically significant differences were found only in Group A (1s) compared to Groups D (7s) and E (10s), as well as in Group B (3s) compared to Group E (10s). With regard to the roughness, statistically significant difference was also observed only in Group E (10s) compared to the other groups. Five SEM images were demonstrated to be very similar to each other, with the conditioning pattern being marked by peaks and valleys, although SEM images of enamel blasted for 1 and 3 seconds showed peaks and valleys in lesser amount. Conclusion: Both loss of dental structure and enamel roughness increased as the time for application of aluminum oxide sandblasting also increased; application of aluminum oxide sandblasting for 1 and 3 seconds produced less loss of enamel structure compared to the 10-second application; more roughness can be obtained with application of aluminum oxide sandblasting for 10 seconds; however, the morphological aspect of the tooth enamel is very similar, regardless of the application time.
13

Efeito de diferentes protocolos de jateamento sobre a durabilidade de união de uma cerâmica ao cimento resinoso

Paschoalino, Vivian Espirito Santo Massi 27 August 2014 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-05-05T12:24:43Z No. of bitstreams: 1 vivianespiritosantomassipaschoalino.pdf: 3537602 bytes, checksum: bc4534be6df769875e1988bea359c413 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-06-07T15:37:36Z (GMT) No. of bitstreams: 1 vivianespiritosantomassipaschoalino.pdf: 3537602 bytes, checksum: bc4534be6df769875e1988bea359c413 (MD5) / Made available in DSpace on 2016-06-07T15:37:36Z (GMT). No. of bitstreams: 1 vivianespiritosantomassipaschoalino.pdf: 3537602 bytes, checksum: bc4534be6df769875e1988bea359c413 (MD5) Previous issue date: 2014-08-27 / FAPEMIG - Fundação de Amparo à Pesquisa do Estado de Minas Gerais / Este estudo avaliou a molhabilidade, a morfologia superficial e a influência da ciclagem térmica sobre a resistência de união entre um cimento resinoso e uma cerâmica de zircônia estabilizada por ítrio (Y-TZP) submetida a diferentes protocolos de jateamento. Foram confeccionados 35 discos (diâmetro: 15mm, espessura: 2mm) cerâmicos sinterizados LAVA All-Ceramic System (3M Espe – Seefeld - Alemanha). Os discos foram divididos randomicamente (n=5): A45 - jateamento AL2O3 45μm; A80 - jateamento AL2O3 80μm; C30 - jateamento AL2O3 revestido por SiO2 30μm (Cojet); R30 - Jateamento AL2O3 revestido por SiO2 30μm (Rocatec Soft);R110 - jateamento AL2O3 revestido por SiO2 110μm (Rocatec Plus); R110R30 - R110 + R30; ST - sem tratamento. O jateamento foi realizado de forma padronizada a pressão constante de 2,5bars, distância de 10mm, em movimentos circulares durante 90s. Para o teste de cisalhamento com e sem ciclagem (n=10) sobre o disco cerâmico já fixado no cilindro de resina acrílica foram colocados com cera utilidade quatro matrizes transparentes cilíndricas (Tygon tubing, TYG-030, Saint-Gobain PerformancePlastic, Maime Lakes, FL, EUA – 3 mm de diâmetro interno por 3 mm de altura). As superfícies cerâmicas foram silanizadas por 60s (Monobond S-Ivoclar-Vivadent- Schaan-Liechtenstein) com microbrush (Vigodent, Rio de Janeiro,RJ, Brasil) internamente ao tygon tubing na zircônia de forma ativa por 60s, e realizada a secagem com leve jato de ar por 20 segundos. Foram preenchidas com cimento resinoso Panavia F®(Kuraray, Okayama, Japão) com o auxílio de uma seringa centrix com ponta (Accudose agulha) (Polidental Ind. e Com. Ltda- São Paulo- SP, Brasil). A fotopolimerização foi realizada com o LED Radii-Cal (SDI-Pinheiros-SP,Brasil) com intensidade de 1200mW/cm e tempo de polimerização de 40 segundos. Após, armazenadas em água destilada na estufa (Olidef- Ribeirão Preto - São Paulo-Brasil), à 37ºC durante 24 horas, as matrizes foram removidas com o auxílio de lâminas de bisturi número 12 (Becton Dickinson-New Jersey -EUA). Depois deste período metade das amostras foram submetidas a 3.000 ciclos de termociclagem em uma cicladora Térmica (Ética Equipamento Científicos S/A- São Paulo- Brasil). A outra metade, posteriormente foi levada ao ensaio de cisalhamento (EMIC-DL 2000 - São José dos Pinhais, Paraná). Para análise estatística utilizaram-se os testes ANOVA (dois fatores) e Tukey (α=0,05). Em seguida, a superfície fraturada foi inspecionada em estereomicroscópio (Discovery.V20, Carl Zeiss, LLC, EUA), (n=2) com magnificação de 9X. O modo de fratura foi classificado em três tipos diferentes: Adesiva, Mista e Coesiva. Dois discos a mais de cada grupo (n=2) tiveram suas superfícies jateadas e foram observadas (2000x) em Microscópio Eletrônico de Varredura FEI INSPECT S50 (Brno, República Tcheca). O ângulo de contato foi mensurado por goniometria (Rame-Hart, INC., 100-00, Contact Angle Goniometers - Montain Lakes – EUA)(n=5) em cada amostra, antes e após o protocolo de jateamento. Uma gota de água destilada foi colocada sobre a superfície cerâmica com uma seringa e o ângulo de contato foi medido durante 20 segundos (30 Frames por segundo). Para análise estatística utilizou-se os testes ANOVA (um fator) e Tukey (α=0,05). Observou-se que na ausência da ciclagem térmica, o tratamento de superfície não influenciou na resistência de união (p=0,238). Grupo A80(12,42±4,08); A45(14,38±4,95); C30(16,86±4,53); R30(13,99±5,55); R110(14,02±5,03); R110R30(11,75±4,19); ST(10,57±4,10). A ciclagem térmica influenciou os valores de resistência de união de todos os grupos (p=0,399). Os maiores valores de resistência de união após ciclagem térmica foram obtidos para os grupos A80 (4,927bc±1,53) e R110 (7,175bc±1,34), em comparação com os grupos ST 11 (1,86e±0,30), C30 (2,132e±0,73) e R110R30 (3,251de±1,37). Para todas as amostras analisadas as falhas foram consideradas adesivas. As fotomicrografias ilustram superfícies mais homogêneas para os grupos que apresentaram menores ângulos C30 (62,6;de±0,91), R30 (61,91e±1,05) e R110R30 (61,54e±1,02). O jateamento influenciou estatisticamente no valor do ângulo de contato, onde o grupo ST (110,61a±0,90) apresentou maior ângulo e os grupos R110R30 (61,54e±1,02), R30 (61,91e±1,05), C30 (62,66de±0,91) e A45 (65,50d±0,94) apresentaram os menores ângulos respectivamente. Conclui-se que o jateamento com C30, R30 e R110R30 proporcionaram maior molhabilidade de superfície da cerâmica estudada. Os maiores valores de resistência de união foram para os grupos onde se realizou jateamento com óxido de alumínio 80μm e com Rocatec 110 μm. Apesar dessa união não ser durável. Partículas maiores apesar de causarem maiores danos a superfície cerâmica, produzem valores de resistência de união altos. O protocolo de jateamento de silicatização com partículas maiores foi o tratamento que promoveu ao mesmo tempo maior molhabilidade e maior resistência de união. / This study evaluated the wettability, surface morphology and the influence of thermocycling on the bond strength of a resin cement and a zirconia ceramic stabilized by yttrium (Y-TZP) under different blasting protocols. Were made 35 discs (diameter: 15mm, thickness: 2 mm) sintered ceramic LAVA All-Ceramic System (3M Espe - Seefeld - Germany). The discs were randomly divided (n = 5): A45 - blasting Al2O3 45μm; A80 - blasting Al2O3 80μm; C30 - blasting Al2O3 coated SiO2 30μm (Cojet); R30 - Blasting Al2O3 coated SiO2 30μm (Rocatec Soft); R110 - blasting Al2O3 coated SiO2 110μm (Rocatec Plus); R110R30 - R110 + R30; ST - untreated. The blast was standardized in the constant pressure 2,5bars, distance 10mm, circular motion during 90s. For the shear test with and without cycling (n = 10) on the ceramic disc already fixed in the cylinder of acrylic resin were placed with wax utility four cylindrical transparent matrices (Tygon tubing, TYG-030, Saint-Gobain PerformancePlastic, Maime Lakes, FL, USA - 3 mm internal diameter by 3 mm height). The ceramic surfaces were silanized for 60 seconds (Monobond S-Ivoclar-Vivadent- Schaan-Liechtenstein) with microbrush (Vigodent, Rio de Janeiro, RJ, Brazil) internally to tygon tubing in zirconia actively for 60 seconds, and held drying with light air jet for 20 seconds. Were filled with Panavia F ® (Kuraray, Okayama, Japan) with the aid of a syringe with tip centrix (AccuDose needle) (Polidental Ind. E Com. Ltda- São Paulo-SP, Brazil). The curing was performed with the LED-Cal Radii (SDI-Pine-SP, Brazil) with an intensity of 1200mW / cm and polymerization time of 40 seconds. After stored in distilled water in the oven (Olidef- Ribeirão Preto - São Paulo-Brazil), at 37 ° C for 24 hours, the arrays were removed with the help of number 12 scalpel blades (Becton Dickinson-New Jersey-US). After this period half of the samples were subjected to 3,000 cycles of thermal cycling in a thermal cycler (Ethics Scientific Equipment S / Sao Paulo-A- Brazil). The other half, was later taken to the shear test (EMIC DL-2000 - São José dos Pinhais, Paraná). For statistical analysis we used the ANOVA (two factors) and Tukey (α = 0.05). Then the fractured surface was inspected in stereo (Discovery.V20, Carl Zeiss, LLC, USA) (n = 2) with magnification 9X. The fracture mode was classified into three different types: Adhesive, Mixed and Cohesive. Two discs over each group (n = 2) had their blasted surfaces and observed (2000x) in Scanning Electron Microscope FEI INSPECT S50 (Brno, Czech Republic). The contact angle was measured by goniometer (Rame-Hart, Inc., 100-00, Contact Angle Goniometers -. Montain Lakes - USA) (n = 5) in each sample before and after blasting protocol. A drop of distilled water was placed on the ceramic surface with a syringe and the contact angle was measured 20 seconds (30 frames per second). Statistical analysis was performed using ANOVA (one factor) and Tukey (α = 0.05). It was observed that in the absence of thermal cycling, the surface treatment did not influence the bond strength (p = 0.238). A80 group (12.42 ± 4.08); A45 (14.38 ± 4.95); C30 (16.86 ± 4.53); R30 (13.99 ± 5.55); R110 (14.02 ± 5.03); R110R30 (11.75 ± 4.19); ST (10.57 ± 4.10). Thermocycling influence the bond strength values of all the groups (p = 0.399). The higher bond strength values were obtained after thermocycling for the A80 groups (4,927bc ± 1.53) and R110 (7,175bc ± 1.34) compared with the ST group (1,86e ± 0.30) , C30 (2,132e ± 0.73) and R110R30 (3,251de ± 1.37). For all the samples analyzed were considered failures adhesive. The photomicrographs illustrate more homogeneous surfaces for the groups with smaller angles C30 (62.6; of ± 0.91), R30 (61,91e ± 1.05) and R110R30 (61,54e ± 1.02). The blasting statistically influence the value of the contact angle, where the ST group (110,61a ± 0.90) had a higher 13 angle and R110R30 groups (1.02 ± 61,54e), R30 (61,91e ± 1.05 ), C30 (62,66de ± 0.91) and A45 (65,50d ± 0.94) had the lowest angles respectively. It follows that the blasting C30, R30 and R110R30 provided higher wettability of the surface of the studied ceramics. The highest bond strength values were for the groups where they underwent blasting with aluminum oxide 80μm and Rocatec 110 microns. Despite this union will not be durable. Although larger particles causing greater damage to the ceramic surface, produce higher bond strength values. The silica coating blasting protocol with larger particles was the treatment that promoted while higher wettability and higher bond strength.
14

EFEITOS DO PRÉ-TRATAMENTO DENTINÁRIO E TEMPERATURA DO ADESIVO NA RESISTÊNCIA ADESIVA DE UM SISTEMA ADESIVO UNIVERSAL / EFFECTS OF DENTIN PRETREATMENT AND ADHESIVE TEMPERATURE ON BOND STRENGTH OF A UNIVERSAL ADHESIVE SYSTEM

Sutil, Bruna Gabrielle da Silva 28 July 2016 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This study aimed to evaluate the effects of dentin pretreatment and temperature on the bond strength of a universal adhesive system to dentin. Ninety-six extracted non-carious human third molars were randomly divided into 12 groups (n=8) according to Scotchbond Universal Adhesive (SbU) applied in self-etch (SE) and total-etch (TE) mode, adhesive temperature (20ºC or 37ºC) and sodium bicarbonate or aluminum oxide air abrasion. After composite build up, bonded sticks with cross-sectional area of 1 mm² were obtained to evaluate the microtensile bond strength (μTBS). The specimens were tested at a crosshead speed of 0.5 mm/min on a universal testing machine until failure. Fractured specimens were analyzed under stereomicroscope to determine the failure patterns in adhesive, cohesive (dentin or resin) and mixed fractures. The microtensile bond strength data was analyzed using to two-way ANOVA and Tukey s test (p<0.01). Interaction between treatment and temperature was statistically significant to SbU applied in SE technique. Both dentin treatments showed higher bond strength to TE mode, regardless of adhesive temperature. When compared to control group, sodium bicarbonate increased bond strength of SbU in SE mode. Adhesive temperature did not significantly affect the μTBS of tested groups. Predominantly, adhesive failure was observed for all groups. Thus, the dentin pretreatment may be an alternative to improve the adhesive properties of the Scotchbond Universal adhesive system. / O presente estudo avaliou os efeitos do jateamento de partículas abrasivas e da temperatura sobre a resistência adesiva de um sistema adesivo universal à dentina. Utilizou-se 96 terceiros molares humanos hígidos e extraídos, divididos aleatoriamente em 12 grupos (n=8) de acordo com o adesivo Scotchbond Universal (SBU) aplicado no modo autocondicionante (SE) ou condicionamento ácido total (TE), temperatura do adesivo (20ºC ou 37ºC) e jateamento da dentina com partículas de óxido de alumínio ou bicarbonato de sódio. Após a realização das restaurações, foram obtidos espécimes em forma de palito com área seccional de 1 mm² para avaliar a resistência adesiva através do teste de microtração. O teste foi realizado em uma máquina de ensaio universal, a uma velocidade de 0,5 mm/min até a fratura ocorrer. As fraturas foram analisadas sob estereomicroscopia para classificar as falhas em adesiva, coesiva (resina ou dentina) e mista. Os dados foram submetidos ao teste ANOVA a dois fatores e ao teste de Tukey. A interação entre tratamento e temperatura foi estatisticamente significante (p<0,01) para SBU SE. Ambos os tratamentos da dentina resultaram em valores maiores de resistência adesiva para SBU no modo TE, independente da temperatura do adesivo. Já para SBU aplicado na técnica autocondicionante, apenas o jateamento com bicarbonato de sódio foi significativamente diferente quando comparado ao grupo que não recebeu tratamento. O adesivo aquecido não teve influência significativa sobre a resistência adesiva à microtração, para todos os grupos testados. As fraturas adesivas foram predominantes para todos os grupos. Dessa forma, o pré-tratamento dentinário pode ser uma alternativa para melhorar as propriedades adesivas do sistema adesivo Scotchbond Universal.
15

Effect of chairside surface treatments on biaxial flexural strength and subsurface damage in monolithic zirconia for dental applications

Wongkamhaeng, Kan 01 May 2016 (has links)
Objective: The goal of the present study was to investigate the effect of chairside surface treatments on biaxial flexural strength and subsurface damage of monolithic zirconia ceramics. Methods: Specimens (15x15x1.2 mm3) were prepared by sectioning from commercially available zirconia blanks (BruxZirTM) and sintering according to manufacturer's recommendations. Fully dense specimens were randomly divided into five groups (n=30) and treated as follows; 1) as-sintered (AS) 2) air abraded with 50 μm alumina fine particles (AAF), 3) air abraded with 250 μm coarse alumina particles (AAC), 4) ground (G), and 5) ground and polished (GP) to mimic chairside and dental laboratory treatments. Microstructural changes were thoroughly characterized by optical and scanning electron microscopy, surface profilometry and atomic force microscopy. Crystalline phases and their depth profile were investigated by x-ray diffraction (XRD) and grazing incidence x-ray diffraction (GIXRD). Results were analyzed by Kruskal-Wallis test and Tukey's adjustment for multiple comparisons. A 0.05 level of significance was used. Reliability was evaluated by Weibull analysis. Results: All treatment groups exhibited a significant difference in mean surface roughness (Rq) compared to the as-sintered group (p<0.05). The AAC group showed the highest surface roughness at 1.08 ± 0.17 μm, followed by the G, AAF and AS groups. The GP group exhibited the lowest surface roughness. The group air abraded with fine particles showed the highest mean biaxial flexural strength (1662.62 ± 202.58 MPa), but was not different from the ground and polished group (1567.19 ± 209.76 MPa). The groups air abraded with coarse particles or ground with diamond bur exhibited comparable mean biaxial flexural strength at 1371.37 ±147.62 MPa and 1356.98 ±196.77 MPa, respectively. The as-sintered group had the lowest mean biaxial flexural strength at 1202.29 ±141.92 MPa. The depth of compressive stress layer, measured by GIXRD was approximately 50 μm in the AAF group, followed by the AAC group with ~35 μm, ~10 μm for the ground group and ~5 μm for the ground and polished group. Deep subsurface cracks were observed in the AAC group (~80 μm in depth) and G group (~25 μm in depth), whereas shallower flaws were present in the AAF and GP groups at 10 and 3 μm, respectively. Weibull analysis represented a greater reliability in zirconia specimens treated with air abrasion groups. Conclusions: Surface treatments induced the t-m transformation in 3Y-TZP and associated development of compressive stresses to a depth that varied with the severity of the treatment performed. GIXRD revealed that AAF led to the thickest compressive stress layer, followed by AAC, G and GP. SEM revealed that subsurface damage was most severe with AAC, followed by G, AAF and GP. We propose that the flexural strength results can be explained by the difference between the depth of the compressive stress layer induced by the transformation and the depth of the subsurface flaws.
16

Opravy kompozitních rekonstrukcí v prevenci ztrát zubních tkání. Dlouhodobá odolnost vazby kompozit-kompozit v různých prostředích. / Prevention of dental tissue loss by composite restoration repairs. Long-term durabillity of composite to composite bond in various environments.

Comba, Lukáš January 2020 (has links)
in english Introduction: Composite restorations in the oral cavity are exposed to an aggressive environment and mechanical challenge that gradually impairs their physical and mechanical properties. This may result in an enhanced wear rate, loss of esthetic properties and an increased risk of a restoration fracture or its marginal failure with a negative impact on the restoration's durability. Worn or failed restorations are usually completely replaced, which increases the irreversible loss of dental hard tissues. Repair of composite restorations by their partial replacement is therefore a minimally invasive, preventive and less time-consuming alternative to their complete replacement and increases their longevity. In the oral cavity, the adhesive bond between the existing composite restoration and the repair composite resin is exposed to various chemical substances and mechanical stress, e.g. surfactants in toothpastes, which can initiate its degradation. By decreasing the surface tension, the penetration of water into the adhesive joint can be enhanced, accelerating the hydrolysis of the adhesive and reducing the composite repair strength. The major and not yet fully resolved issue of composite repairs is how to achieve a strong and durable bond between the existing and repair composite materials....
17

Avaliação da resistência ao cisalhamento da zircônia após diferentes tratamentos de superfície / Evaluation of shear bond strength of zirconia after different surface treatments

Santos, Livia Aguiar 06 May 2011 (has links)
Cerâmicas de alto conteúdo cristalino, como a zircônia policristalina tetragonal estabilizada por ítrio (Y-TZP), apresentam ótimas propriedades mecânicas quando comparadas às cerâmicas convencionais, sendo cada vez mais empregadas como materiais restauradores indiretos. Entretanto, seu sucesso também depende da formação de uma união confiável com os agentes de cimentação. Porém, o aumento do conteúdo cristalino modificou as características de adesão entre cerâmica e cimento resinoso, não existindo um protocolo de cimentação bem estabelecido na literatura. Portanto, este estudo teve como objetivo avaliar o efeito na resistência ao cisalhamento de diferentes tratamentos de superfície sobre a zircônia, utilizando dois cimentos resinosos, assim como avaliar as possíveis diferenças no modo das fraturas. Cento e vinte amostras retangulares de zircônia foram incluídas em resina acrílica e divididas em 12 grupos (n=10), de acordo com os tratamentos de superfície e os cimentos (Panavia F e Rely X U100). Para cada cimento, os grupos experimentais foram formados da seguinte maneira: RU e Pa - controle (sem nenhum tratamento de superfície); ApRU e ApPa (aplicação do Alloy Primer); MzRU e MzPa (aplicação do Metal/Zircônia Primer); JatRU e JatPa (jateamento com partículas de óxido de alumínio de 50µm); JatApRU e JatApPa (jateamento e aplicação de Alloy Primer); JatMzRU e JatMzPa (jateamento e aplicação do Metal/Zircônia Primer). Os corpos de prova foram armazenados em água destilada à temperatura de 37°C por 24 horas, antes do teste de cisalhamento em uma máquina de ensaio universal (EMIC). Os valores foram submetidos primeiro a ANOVA a um critério (resistência ao cisalhamento) e teste de Tukey (p 0,05), independente do tratamento e do sistema de cimentação. Em seguida, ANOVA a dois critérios (tratamento de superfície e sistema de cimentação) e o teste de Tukey foram aplicados para observar com maior precisão a interação entre cimento e tratamento de superfície. Os resultados apresentados foram: RU - 11,71a, ApRU - 21,49b,e, MzRU - 30,38c,d, JatRU - 34,40c, JatApRU - 30,66c,d, JatMzRU - 38,06c, Pa - 11,35a, ApPa - 11,98a, MzPa - 11,46a, JatPa - 33,50c, JatApPa - 23,14b,d,e, JatMzPa - 18,66a,e. Por meio dos resultados obtidos foi possível concluir que a resistência ao cisalhamento pode ser melhorada ao utilizar o jateamento com partículas de óxido de alumínio e, para o RelyX U100, somente a aplicação do Metal/Zircônia Primer resultou em valores de adesão comparavéis ao tratamento mecânico. O cimento RelyX U100 apresentou maior resistência de união quando comparado ao Panavia F. / High crystalline content ceramics, such as yttria stabilized tetragonal zirconia polycrystal (Y-TZP), show great mechanical properties when compared to conventional ceramics, being increasingly used as indirect restorative materials. However, its success also depends on the reliable bond formation with luting agents. Though, the high crystalline content modified the adhesiveness between ceramic and resin cement although there isnt any cementing protocol established in literature. Therefore, the purpose of this study was to evaluate the effect of the shear bond strength after different surface treatments on the zirconia, using two resin cements and to evaluate possible differences in fracture modes. One hundred and twenty rectangular samples of zirconia were embedded in acrylic resin and divided into 12 groups (n=10) according to the surface treatments and the cements (Panavia F and RelyX U100). For each cement, the experimental groups were formed as follow: RU and Pa - control (no surface treatment); ApRU and ApPa (application of Alloy Primer); MzRU e MzPa (application of Metal/Zirconia Primer); JatRU and JatPa (air abrasion with 50µm Al2O3 particles); JatApRU and JatApPa (air abrasion and application of Alloy Primer); JatMzRU and JatMzPa (air abrasion and application of Metal/Zirconia Primer). The specimens were stored in distilled water at 37°C for 24 hours prior to the shear bond strength test in a universal testing machine (EMIC). The data were first analyzed by one-way ANOVA (shear bond strength) and Tukey test (p<0.05), regardless of the treatment and the luting system. Then two-way ANOVA (surface treatment and luting system) and the Tukey test were applied in order to observe more accurately the interaction between cement and surface treatments.The results presented were: RU 11.71a, ApRU 21.49b,e, MzRU 30.38c,d, JatRU 34.40c, JatApRU 30.66c,d, JatMzRU 38.06c, Pa 11.35a, ApPa 11.98a, MzPa 11.46a, JatPa 33.50c, JatApPa 23.14b,d,e, JatMzPa 18.66a,e. Based on the results obtained, it was possible to conclude that the shear bond strength can be improved when air abrasion was used with aluminum-oxide particles and for the RelyX U100, only the application of Metal / Zirconia Primer resulted in adhesion values comparable to mechanical treatment. The RelyX U100 cement showed higher bond strength when compared to Panavia F.
18

Infiltração marginal em restaurações de resina composta após tratamento dentinário com abrasão a ar e sistemas adesivos

Capote, Ticiana Sidorenko de Oliveira [UNESP] 17 February 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-02-17Bitstream added on 2014-06-13T21:05:38Z : No. of bitstreams: 1 capote_tso_dr_arafo.pdf: 505094 bytes, checksum: 31fcf59ff0ad841243d74c40158077eb (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A infiltração marginal em restaurações de resina composta classe V foi avaliada nas margens cervical e oclusal de dentes decíduos e permanentes após diferentes tratamentos dentinários. Os preparos cavitários foram confeccionados nas faces vestibular e lingual de 25 molares decíduos e 25 terceiros molares permanentes hígidos utilizando fresas e instrumentos rotatórios e, posteriormente foram divididos em 5 grupos, cada um contendo 10 cavidades: grupo 1 (abrasão a ar e sistema Scotchbond Multi-Uso), grupo 2 (ácido fosfórico e Scotchbond Multi-Uso), grupo 3 (sistema auto-condicionante Clearfil SE Bond), grupo 4 (abrasão a ar, ácido fosfórico e Scotchbond Multi-Uso) e grupo 5 (abrasão a ar e Clearfil SE Bond), todos restaurados com resina Z100. Após polimento, os dentes foram submetidos à termociclagem (500 ciclos) e imersos em solução de nitrato de prata a 50%. Depois de seccionados, foram analisados em lupa estereoscópica (40x) utilizando escores de 0 a 4. Para avaliação dos diferentes tratamentos e tipos de margem, empregou-se o teste de Kruskal-Wallis, seguido de comparações múltiplas dos postos médios pelo teste de Dunn e a comparação entre dentes decíduos e permanentes foi realizada pelo teste de Mann-Whitney, com nível de significância de 5%. A aplicação do sistema de abrasão a ar e Scotchbond Multi-Uso, sem condicionamento ácido produziu os maiores valores de infiltração marginal em dentes decíduos e permanentes. Os resultados demonstraram que a utilização do sistema de abrasão associado a condicionadores ácidos resultou em menor infiltração marginal em dentes decíduos, embora não tenha havido diferença estatisticamente significante. O sistema auto-condicionante promoveu o menor valor de infiltração na margem cervical e o condicionamento com ácido fosfórico acompanhado pelo sistema... / Marginal leakage in gingival and occlusal margins of Class V composite restorations in deciduous and permanent teeth was investigated. Cavities were prepared with burs in high speed in facial and lingual surfaces of 25 deciduous molars and 25 third permanent molars. The specimens were divided into 5 groups of 10 preparations each: group 1 (air abrasion and Scotchbond Multi Purpose), group 2 (phosphoric acid and Scotchbond Multi Purpose), group 3 (Clearfil SE Bond self-etching system), group 4 (air abrasion, phosphoric acid and Scotchbond Multi Purpose) and group 5 (air abrasion and Clearfil SE Bond), all groups were restored with Z100 composite resin. After polish, the teeth were subjected to 500 thermal cycling and immerged in 50% silver nitrate solution. After sectioning, the specimens were analyzed with a stereomicroscope (40x) for assessment of microleakage according to the degree of dye penetration (scores of 0-4). The Kruskal-Wallis test followed by Dunn Multiple Comparison test were performed in order to evaluate the differences among the experimental groups. The Mann-Whitney test was performed to evaluate the differences among deciduous and permanent teeth at a 5% level of significance. Air abrasion and Scotchbond Multi-Purpose without etching, showed the greatest leakage in deciduous and permanent teeth. Air abrasion and acid condicionings produced little leakage in deciduous teeth. The self-etching system demonstrated the least leakage in gingival margins and Scotchbond Multi-Purpose showed the best results in occlusal margins of deciduous teeth. No significant difference was observed among gingival and occlusal margins in deciduous teeth. Air abrasion groups demonstrated the greatest leakage in permanent teeth. Scotchbond Multi- Purpose with phosphoric acid produced the least leakage in permanent teeth, with greater leakage in gingival... (Complete abstract, click electronic address below)
19

Influência da técnica de preparo cavitário na microinfiltração marginal em restaurações de dentes decíduos /

Silva, Vlamir Oliveira da. January 2002 (has links)
Resumo: O objetivo desse trabalho foi avaliar a influência da forma do preparo cavitário na microinfiltração marginal em restaurações em dentes decíduos. Foram preparadas canaletas medindo 2,0 mm nas faces vestibular e lingual de molares decíduos que foram divididas aleatoriamente em 3 grupos de acordo com a técnica de preparo cavitário: Grupo I - alta rotação associado à ponta diamantada; Grupo II - sistema de abrasão a ar; e Grupo III - laser Er:YAG. Após o condicionamento com ácido fosfórico por 15 segundos, foi utilizado o adesivo Single Bond (3M) e a resina Filtek Flow (3M) para restaurar as canaletas. Os espécimes foram então mantidos em estufa a 37ºC por 6 dias, termociclados (500 ciclos com temperatura variando entre 5 e 55ºC), isolados e colocados em solução de fucsina básica à 0,5% durante 24 horas. Após serem seccionados a microinfiltração foi avaliada em microscópio ótico ligado a uma câmera de vídeo com 10 X de aumento. Para se avaliar a forma das cavidades medimos os ângulos oclusal, cervical e de abertura das cavidades, bem como a largura e a profundidade das mesmas por meio de fotomicrografias obtidas em MEV. Os resultados demonstraram semelhança estatística entre as larguras dos preparos cavitários, porém os ângulos oclusal, cervical e de abertura das cavidades apresentaram-se diferentes estatisticamente e que não houve microinfiltração marginal em nenhum dos grupos avaliados e que a diferença na forma de preparo das cavidades não influenciou na microinfiltração marginal dos espécimes estudados. / Abstract: The aim of this research was the evaluation of the cavity prepare technique on the marginal microleakage in deciduous teeth. Cavities measuring 2.0 mm were prepared on the buccal and lingual faces and were divided into three groups according to the cavity prepare technique: Group I - High speed associated to diamond bur; Group II - air abrasion system; and Group III - Er:YAG laser. After the phosphoric acid etching for 15 seconds, the Single Bond (3M) adhesive and te Filtek Flow (3M) were used for the restoration of the cavities. Then the sample was stored at 37ºC for 6 days, termocycled (500 cycles with temperature varying from 5 to 55º C), isolated and immersed in a 0.5% funcsin solution for 24 hours. After being sectioned the microleakage was examined with a magnification optical microscope connected to a color video camera. In order to evaluate the shape of the cavities the occlusal, cervical and cavity opening angles were measured, as well as the width and depth of then, using SEM photographs. The results showed that there was no marginal microleakage in any of the evaluated groups and that the difference in the cavity shape did not influence the marginal infiltration on the studied samples. / Orientador: Rita de Cássia Loiola Cordeiro / Coorientador: Maria Cristina Borsatto / Banca: Lourdes Aparecida Martins dos Santos Pinto / Banca: Ângela Cristina Cilense Zuanon / Banca: Delsa Deise Machetti Kanaan / Banca: Luís José Floriam / Doutor
20

Infiltração marginal em restaurações de resina composta após tratamento dentinário com abrasão a ar e sistemas adesivos /

Capote, Ticiana Sidorenko de Oliveira. January 2005 (has links)
Orientador: Angela Cristina Cilense Zuanon / Banca: Maria Aparecida de Andrade Moreira / Banca: Maria Cristina Borsatto / Banca: Gelson Luis Adabo / Banca: Josimeri Hebling / Resumo: A infiltração marginal em restaurações de resina composta classe V foi avaliada nas margens cervical e oclusal de dentes decíduos e permanentes após diferentes tratamentos dentinários. Os preparos cavitários foram confeccionados nas faces vestibular e lingual de 25 molares decíduos e 25 terceiros molares permanentes hígidos utilizando fresas e instrumentos rotatórios e, posteriormente foram divididos em 5 grupos, cada um contendo 10 cavidades: grupo 1 (abrasão a ar e sistema Scotchbond Multi-Uso), grupo 2 (ácido fosfórico e Scotchbond Multi-Uso), grupo 3 (sistema auto-condicionante Clearfil SE Bond), grupo 4 (abrasão a ar, ácido fosfórico e Scotchbond Multi-Uso) e grupo 5 (abrasão a ar e Clearfil SE Bond), todos restaurados com resina Z100. Após polimento, os dentes foram submetidos à termociclagem (500 ciclos) e imersos em solução de nitrato de prata a 50%. Depois de seccionados, foram analisados em lupa estereoscópica (40x) utilizando escores de 0 a 4. Para avaliação dos diferentes tratamentos e tipos de margem, empregou-se o teste de Kruskal-Wallis, seguido de comparações múltiplas dos postos médios pelo teste de Dunn e a comparação entre dentes decíduos e permanentes foi realizada pelo teste de Mann-Whitney, com nível de significância de 5%. A aplicação do sistema de abrasão a ar e Scotchbond Multi-Uso, sem condicionamento ácido produziu os maiores valores de infiltração marginal em dentes decíduos e permanentes. Os resultados demonstraram que a utilização do sistema de abrasão associado a condicionadores ácidos resultou em menor infiltração marginal em dentes decíduos, embora não tenha havido diferença estatisticamente significante. O sistema auto-condicionante promoveu o menor valor de infiltração na margem cervical e o condicionamento com ácido fosfórico acompanhado pelo sistema... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Marginal leakage in gingival and occlusal margins of Class V composite restorations in deciduous and permanent teeth was investigated. Cavities were prepared with burs in high speed in facial and lingual surfaces of 25 deciduous molars and 25 third permanent molars. The specimens were divided into 5 groups of 10 preparations each: group 1 (air abrasion and Scotchbond Multi Purpose), group 2 (phosphoric acid and Scotchbond Multi Purpose), group 3 (Clearfil SE Bond self-etching system), group 4 (air abrasion, phosphoric acid and Scotchbond Multi Purpose) and group 5 (air abrasion and Clearfil SE Bond), all groups were restored with Z100 composite resin. After polish, the teeth were subjected to 500 thermal cycling and immerged in 50% silver nitrate solution. After sectioning, the specimens were analyzed with a stereomicroscope (40x) for assessment of microleakage according to the degree of dye penetration (scores of 0-4). The Kruskal-Wallis test followed by Dunn Multiple Comparison test were performed in order to evaluate the differences among the experimental groups. The Mann-Whitney test was performed to evaluate the differences among deciduous and permanent teeth at a 5% level of significance. Air abrasion and Scotchbond Multi-Purpose without etching, showed the greatest leakage in deciduous and permanent teeth. Air abrasion and acid condicionings produced little leakage in deciduous teeth. The self-etching system demonstrated the least leakage in gingival margins and Scotchbond Multi-Purpose showed the best results in occlusal margins of deciduous teeth. No significant difference was observed among gingival and occlusal margins in deciduous teeth. Air abrasion groups demonstrated the greatest leakage in permanent teeth. Scotchbond Multi- Purpose with phosphoric acid produced the least leakage in permanent teeth, with greater leakage in gingival... (Complete abstract, click electronic address below) / Doutor

Page generated in 0.0827 seconds