• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 34
  • 4
  • Tagged with
  • 38
  • 38
  • 29
  • 29
  • 14
  • 14
  • 14
  • 8
  • 7
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Validación del método de valoración de Glimepiride presentación comprimido de 4 mg. por el método de cromatografía líquida de alta performance H.P.L.C.

Silva Cajas, Guido Vidal January 2004 (has links)
La validación es un requisito imprescindible para el cumplimiento de las Buenas Prácticas de Laboratorio lo que está establecido por agencias regulatorias y las diversas Farmacopeas. Para la validación de un método analítico se deben evaluar una serie de parámetros como: la selectividad, linealidad, precisión, exactitud, limites de detección y cuantificación, rango y robustez. A partir de que no se tiene un modelo único para validar y que los parámetros a evaluar cambian de acuerdo con los requisitos legales de las diferentes entidades, el presente trabajo plantea el desarrollo de la validación de un método analítico propio por Cromatografía Líquida de Alta Performance para Glimepiride bajo la forma farmacéutica de comprimidos. Se ha desarrollado un método selectivo por HPLC para esta nueva sulfonilurea. El ensayo fue cuantificado en columna de fase reversa, flujo de 1 mL/min, longitud de onda de 228 nm con detector de arreglo de diodos, fase movil isocratico, volumen de inyeccion de 20 uL, temperatura de 30° C y a la concentración de 160 ug/mL de glimepiride en solvente orgánico. Con los parámetros definidos para el trabajo, se ejecuta el protocolo de validación del método para lo cual se cuenta con el diseño experimental y los procedimientos estadísticos, concluyendo que la metodología analítica propuesto es lineal, exacta, y selectiva, cumpliendo así con los parámetros de validación establecidos en las obras oficiales; por lo cual el método validado es confiable y puede ser empleado en los análisis de rutina. / Validation is an indispensable requisite for the compliment of Good Laboratory Practices. It is settled by regulatory agencies and the pharmacopoeia. The Validation of an analytic method includes the evaluation of a series of parameters. They are: selectivity, linearity, precision, detection and quantitation limit, accuracy, and robustness. Starting form the criteria that there is no a single model to validate, and the fact of the parameters to evaluate it change according the legal requirements of different organizations, this work propose the development and validation of an HPLC analytical method for the Glimepiride in the pharmaceutical presentation of tablets. A sensitive high-performance liquid chromatographic method has been developed for this new sulphonylurea. The assay was quantitated on a reversed-phase column, flow of 1 mL/min, absorbance at 228 nm with diode array detector, isocratic run, injection volume of 20 uL, temperature of 30° C and final concentration of 160 ug/mL for glimepiride in organic solvent .When the conditionsn in this work were defined, we started the analysis for theevaluation of validation’s parameters. It was shown by the experimental design and the statistic procedures, that the proposed analytical technique is linear, is accurate, is precise and finally is selective. The proposed technique accomplished all established validation’s parameters established in the official papers. Thus, the validate method is reliable and it can be used in the routine analyses. / Tesis
22

Determinación por HPLC de residuos de insecticida órganofosforado (Methamidophos) en tomates comercializados en Lima-Perú

Campos Chávez, Cristian, Palacios Alcántara, Abimael January 2010 (has links)
En el presente trabajo se realizó el análisis toxicológico de identificación y cuantificación de los residuos del insecticida órganofosforado METHAMIDOPHOS en 25 muestras de tomates, en tres mercados mayoristas (La Parada, 3 de Febrero y Manzanilla) y dos mercados minoristas (N° 1 – San Juan de Lurigancho y Ceres – Ate), todos ubicados en el departamento de Lima. El análisis de identificación cualitativa se realizó por Cromatografía en Capa Fina (CCF) utilizando los Rf y por Cromatografía Líquida de Alta Resolución (HPLC) utilizando los tiempos de retención. El análisis Cuantitativo se realizó por Cromatografía Líquida de Alta Resolución (HPLC), utilizando las áreas integradas de los picos en los cromatogramas obtenidos. Se determinó la presencia de Methamidophos en la totalidad de las muestras analizadas. De las 25 muestras analizadas solo una muestra (4%) perteneciente al mercado mayorista 3 de Febrero presentó una concentración máxima de 1.0369 ppm de Methamidophos excediendo el Límite Máximo Residual (LMR) para el Methamidophos en tomates según Codex Alimentarius que es de 1.0 ppm. Palabras Clave: tomate, plaguicidas, órganofosforados, Methamidophos, LMR, CCF, HPLC. / In the present study was conducted toxicological analysis for the identification and quantification of the organophosphate insecticide METHAMIDOPHOS residue in 25 samples of tomatoes, three wholesale markets (La Parada, 3 de Febrero and Manzanilla) and two retail markets (No. 1- San Juan de Lurigancho and Ceres – Ate) , all located in the department of Lima. Qualitative identification analysis was performed by Thin Layer Chromatography (TLC) using the Rf and High-Resolution Liquid Chromatography (HPLC) using the retention times. Quantitative analysis was performed by high resolution liquid chromatography (HPLC) using the integrated areas of peaks in the chromatograms obtained. We determined the presence of Methamidophos in all samples. Of the 25 samples tested only one sample (4%) belonging to the wholesale market 3 de Febrero present a maximum concentration of 1.0369 ppm of Methamidophos exceeding the Maximum Residual Limit (MRL) for Methamidophos on tomatoes as Codex Alimentarius is 1.0 ppm. Key Words: tomato, insecticide, organophosphates, Methamidophos, MRL, TLC, HPLC.
23

Validación de método analítico de valoración de naproxeno sódico 550 mg. tableta por cromatografía líquida de alta performance

Medina Julca, Jessica, Berrocal Quinto, Jorge January 2008 (has links)
La validación del método analítico es parte integral del sistema de control de calidad, puesto que confiere fiabilidad a los resultados analíticos obtenidos en un laboratorio de análisis, a fin de asegurar que un medicamento cumpla los parámetros de calidad establecidos. En este trabajo presentamos la validación de un método analítico de valoración de Naproxeno Sódico 550 mg en tabletas, utilizando la técnica de cromatografía líquida de alta performance establecido en la USP 28. Los parámetros estadísticos empleados en la validación son: La linealidad; que mide la capacidad del método analítico para producir resultados que son proporcionales a la concentración del analito, lo cual queda demostrado en la validación al obtener un coeficiente de correlación r= 0.99992, siendo el valor mínimo permisible de 0.997. La exactitud mide la proximidad de los resultados obtenidos por este método y el valor real. Al aplicar el test de student para demostrar la exactitud del método analítico se obtuvo un texp (1.1932) que es menor al t de las tablas (2.306); por lo tanto no existe diferencia significativa entre la recuperación media y la cantidad añadida de analito, es decir que el porcentaje de recuperación del analito es muy cercano al 100%. / The Validation of analytic methods is an all-round part of the Quality Control System, because it confers reliability to analytical results obtained in the laboratory to ensure that a specific medicine meets stablished quality requirements. This work presents the Validation of an Analytical Method to perform a quantitative analysis to the active component from 550 mg Sodium Naproxeno tablets using High Performance Liquid Chromatography (HPLC) according to the USP 26.The validation is based on enough dates from laboratory which supports validity of analytical methods. Some important statistical parameters are: Linearity, exactitude, precision, selectivity and specificity. Linearity measures the capacity of the analytic method for producing results which are directly proportional to concentration of an active substance within a specific range, called the work range. The exactitude measures how near the results obtained by the chosen method and the real value are. This is often expressed as recovery percentage.
24

Desarrollo y validación de un método analítico para la cuantificación por HPLC de clenbuterol clorhidrato en solución oral-gotas, y análisis comparativo de productos comercializados en el Perú

Leyva Minaya, Elvis Edisson, Pérez Cáceres, Fernando January 2009 (has links)
El análisis por Cromatografía Líquida de Alta Precisión (HPLC) de productos farmacéuticos es una necesidad y es de uso rutinario. Esta técnica evita minimiza los errores que conllevan a situaciones de riesgo al usuario, garantizando que el contenido en el producto sea el correcto. La validación es un proceso establecido que obtiene pruebas documentadas y demostrativas para que un método de análisis sea lo suficientemente fiable y reproducible para producir un resultado previsto dentro de los intervalos definidos. La validación de un método analítico es un requisito necesario para cumplir con las Buenas Prácticas de Manufactura (BPM) y así asegurar la calidad del medicamento. La Técnica Analítica desarrollada y propuesta en el presente trabajo plantea la cuantificación por el método de HPLC de un producto farmacéutico que contiene Clenbuterol Clorhidrato solución oral gotas. En el cual se procedió a la validación del método de análisis evaluando los parámetros que indican las obras oficiales, como son: selectividad, linealidad, precisión, exactitud y robustez. Posteriormente, se elaboró el Protocolo de validación del método de análisis, para lo cual se contó con el diseño experimental y los procedimientos estadísticos, concluyéndose así que el método analítico propuesto es selectivo, lineal, preciso, reproducible y exacto; comprobándose así su validez. / The Analysis by High Precision Liquid Chromatography (HPLC) of pharmaceuticals is a necessity and is routinely used. This technique avoids minimizes errors that lead to situations of risk to the user, ensuring that the contents in the product is correct. Validation is a process established that evidence obtained to document and demonstrates an analytical method is sufficiently reliable and reproducible to produce an intended result within the defined intervals. The analytical method validation is a necessary requirement to comply with Good Manufacturing Practices (GMP) and thus ensure the quality of the product. The analytical technique developed and proposed in this paper discusses the quantification by HPLC of a pharmaceutical product containing Clenbuterol Hydrochloride oral solution drops. In which we proceeded to validate the analysis method evaluating the parameters that indicate the official works, such as: selectivity, linearity, precision, accuracy and robustness. Subsequently developed the Protocol for validation of analytical method, for which they received the experimental design and statistical procedures, concluding that the proposed analytical method is selective, linear, accurate, reproducible and accurate; see that they are valid.
25

Validación del método de valoración de Glimepiride presentación comprimido de 4 mg. por el método de cromatografía líquida de alta performance H.P.L.C.

Silva Cajas, Guido Vidal January 2004 (has links)
La validación es un requisito imprescindible para el cumplimiento de las Buenas Prácticas de Laboratorio lo que está establecido por agencias regulatorias y las diversas Farmacopeas. Para la validación de un método analítico se deben evaluar una serie de parámetros como: la selectividad, linealidad, precisión, exactitud, limites de detección y cuantificación, rango y robustez . A partir de que no se tiene un modelo único para validar y que los parámetros a evaluar cambian de acuerdo con los requisitos legales de las diferentes entidades, el presente trabajo plantea el desarrollo de la validación de un método analítico propio por Cromatografía Líquida de Alta Performance para Glimepiride bajo la forma farmacéutica de comprimidos. Se ha desarrollado un método selectivo por HPLC para esta nueva sulfonilurea. El ensayo fue cuantificado en columna de fase reversa, flujo de 1 mL/min, longitud de onda de 228 nm con detector de arreglo de diodos, fase movil isocratico, volumen de inyeccion de 20 uL, temperatura de 30° C y a la concentración de 160 ug/mL de glimepiride en solvente orgánico. Con los parámetros definidos para el trabajo, se ejecuta el protocolo de validación del método para lo cual se cuenta con el diseño experimental y los procedimientos estadísticos, concluyendo que la metodología analítica propuesto es lineal, exacta, y selectiva, cumpliendo así con los parámetros de validación establecidos en las obras oficiales; por lo cual el método validado es confiable y puede ser empleado en los análisis de rutina. / Validation is an indispensable requisite for the compliment of Good Laboratory Practices. It is settled by regulatory agencies and the pharmacopoeia. The Validation of an analytic method includes the evaluation of a series of parameters. They are: selectivity, linearity, precision, detection and quantitation limit, accuracy, and robustness. Starting form the criteria that there is no a single model to validate, and the fact of the parameters to evaluate it change according the legal requirements of different organizations, this work propose the development and validation of an HPLC analytical method for the Glimepiride in the pharmaceutical presentation of tablets. A sensitive high-performance liquid chromatographic method has been developed for this new sulphonylurea. The assay was quantitated on a reversed-phase column, flow of 1 mL/min, absorbance at 228 nm with diode array detector, isocratic run, injection volume of 20 uL, temperature of 30° C and final concentration of 160 ug/mL for glimepiride in organic solvent .When the conditionsn in this work were defined, we started the analysis for theevaluation of validation’s parameters. It was shown by the experimental design and the statistic procedures, that the proposed analytical technique is linear, is accurate, is precise and finally is selective. The proposed technique accomplished all established validation’s parameters established in the official papers. Thus, the validate method is reliable and it can be used in the routine analyses.
26

Determinación de residuos de cloranfenicol en carnes por cromatografía líquida acoplada a espectrometría de masas

Grande Ortiz, Miguel Angel January 2018 (has links)
Desarrolla un método de identificación y cuantificación de cloranfenicol en carnes por cromatografía liquida acoplada a espectrometría de masas LC-MS-MS. Se utilizó el método de cromatografía líquida de alta resolución acoplada a espectrometría de masas tipo tándem Triple Cuadrupolo Masa-Masa (LC-MS/MS), efectuando su validación según lo establecido por las regulaciones internacionales como la Directiva 96/23/EC 2002 Comisión Decisión Unión Europea, para los parámetros de especificidad, límite de detección (LOD), límite de cuantificación (LOQ), precisión intradía e interdia, exactitud, linealidad y recuperación. Se empleó un sistema de extracción en fase sólida para el análisis de las muestras de carne de pollo, mediante cartuchos de Octadecilsilano C18, con carga de 100 mg y 3 mL de volumen, para la detección de los analitos cloranfenicol (CAF) y su estándar interno cloranfenicol deuterado (CAFD5) evidenciándose las transiciones de 320.90→150.96 m/z, por Monitoreo de Reacción Simple (SRM), para el analito cloranfenicol (CAF) y 325.85→ 155.98 m/z, SRM para el estándar interno cloranfenicol deuterado (CAFD5). Los valores obtenidos durante la validación del método establecieron una muy buena especificidad al no obtener pico cromatográfico alguno en los tiempos de retención del analito cloranfenicol (CAF) y su estándar interno, cloranfenicol deuterado (CAFD5), el límite de detección (LOD) fue de 1,0 ng/mL, correspondiente a 0,1 ng/g, límite de cuantificación (LOQ) de 3,0 ng/mL correspondiente a 0,3 ng/g , precisión intradía: control de calidad A (QCA) 19,61%,control de calidad B (QCB) 4,46% y control de calidad C (QCC) 6,87%, precisión interdia: QCA 3,86%, QCB 15,07% y QCC 3,22%, linealidad con un coeficiente de correlación lineal r= 0.9987 y un porcentaje de recuperación para los seis (06) niveles propuestos entre 84,6% y 105,0% De las veinte seis (26) muestras evaluadas procedentes de 4 mercados de distribución de carne de pollo de las ciudades de Lima y Callao, se evidenció que catorce (14) muestras no cumplieron con el Límite Máximo Residual 2 permitido para el antibiótico cloranfenicol en carne pollo definida por la FDA y la Unión Europea ≤ 0,3 ng/g. Se logró desarrollar un método validado capaz de identificar y cuantificar residuos del antibiótico cloranfenicol en muestras de carne de pollo empleando cromatografía líquida de alta resolución acoplada a espectrometría de masas tipo tándem Triple Cuadrupolo Masa-Masa (LCMS/MS). / Tesis
27

Determinación de triclosán en productos de higiene personal (jabón líquido y gel antibacterial) de diferentes marcas que se expenden en Lima Metropolitana

Risco León, Janet Esperanza January 2018 (has links)
Publicación a texto completo no autorizada por el autor / Se determina la concentración de triclosán en 32 muestras de jabón líquido y gel antibacterial provenientes de 8 marcas diferentes comercializadas en los principales supermercados de Lima Metropolitana. La presencia y concentración de triclosán se determina por el método de Cromatografía Líquida de Alta Resolución (HPLC) debido a que es el método de elección según bibliografías actuales. Como resultados se obtiene que de las 8 marcas evaluadas, el 53% presenta concentraciones de triclosán en un rango que oscila de 0.178% a 0.531%; del total de muestras, el 18.75% supera los límites establecidos por la FDA. En las muestras de jabones líquidos, el 31.25 % supera los límites establecidos por la FDA y en el caso de geles antibacteriales el 6.25 %. Se concluye que las concentraciones de triclosán presente en los jabones líquidos no es significativo a excepción de una de las marcas que si sobrepasa los límites establecidos por la FDA, en el caso de geles antibacteriales las concentraciones de triclosán se encuentran dentro del rango permitido en todas las marcas. Finalmente se recomienda establecer la concentración máxima permisible de triclosán para productos cosméticos en nuestro país debido al potencial riesgo para la salud humana. / Tesis
28

Desarrollo de un método cuantitativo por HPLC para la determinación de ácido fenilglioxílico y ácido mandélico, como indicadores biológicos de la exposición a estireno

Román Olazabal, Lilian January 2017 (has links)
Desarrolla un método cuantitativo por HPLC para la determinación de Ácido Fenilglioxílico (PGA) y Ácido Mandélico (MA), biomarcador para determinar la exposición a estireno; post ensayos preliminares, se optimizó el mismo. Las condiciones cromatográficas son columna C18 x 4,6 mm x 150 mm (5 µm); flujo 0,8 mL/min; volumen de inyección 5 µL; fase móvil buffer K2HPO4 10 mM pH 2,8: Acetonitrilo (90:10); longitud de onda: 254 nm; temperatura 30 °C. La veracidad del método para el análisis de PGA en orina se determinó con Bio-rad (MRC: muestra de referencia certificada). Los resultados de PGA fueron 45,407 mg/L (Bio-Rad Nivel 1) y 218,085 mg/L (Bio-Rad Nivel 2). Se aplicó la t-Student en los datos señalados, cuyos resultados no se diferenciaron significativamente al valor de la MRC. Se usó la recuperación para determinación de la veracidad de MA. El promedio de las recuperaciones en el Nivel 1 (99,9827) y en el Nivel 2 (99,9727) no presentó diferencia significativa con respecto al valor teórico (recuperación 100 %). / Tesis
29

Tamaño y difusión. Construcciones antirracistas en alta resolución para medios peruanos / Size and Broadcasting. Anti-racist Issues in High Definition for Peruvian Media

Solís López, Augusto Pavel 05 August 2021 (has links)
Este ensayo reflexiona sobre cómo la alta definición digital de nuestras pantallas es un fenómeno que conjuga con la noción de racismo simbólico a través de la construcción de experiencias placenteras de marcas audiovisuales. Ello sucede porque el HD va sujeto a estructuras neoliberales digitales que llevan a obtener ingresos y fidelidad, pero que construyen paradojas de autorregulación y estructuras racistas inmutables. La interacción de los medios, los productores y las audiencias se ampara en lo que se ha nombrado ignorancias audiovisuales, creencias falsas o ausencia de creencias reales que se condicen con prácticas antirracistas cuestionables que sitúan el problema racista en lo circunstancial, sin llegar a reconfiguraciones críticas ni estructurales.
30

Efecto de los depósitos de gas somero del fondo marino en las comunidades macrobentónicas del estuario de Bahía Blanca

Bravo, María Emilia 20 March 2019 (has links)
Esta tesis tiene como finalidad caracterizar los depósitos de gas somero de la zona interna del estuario de Bahía Blanca y evaluar el efecto de los sedimentos gasíferos sobre las comunidades bentónicas submareales asociadas. Para tal fin, se mapeó la distribución del gas somero en el estuario mediante el análisis de registros sísmicos de alta resolución. En base a este mapa, se seleccionaron dos sitios de estudio (con gas y control) que sólo difirieron en la presencia de gas en contacto con la superficie del fondo marino. Mediante métodos acústicos se determinó la estratigrafía y morfología del sitio con gas y el área adyacente. Además, se evaluaron los sedimentos gasíferos por medio de los siguientes análisis: granulometría, contenido de materia orgánica, rayos X y medición con HPLC head space. Los organismos bentónicos de ambos sitios fueron comparados en términos de abundancia, biomasa, diversidad, equitatividad, riqueza específica, estructura taxonómica y funcional. El gas se encontró ampliamente distribuido en el estuario, tanto cerca como en contacto con la superficie del fondo marino de la zona interna del estuario de Bahía Blanca. Se evidenció en forma de turbidez acústica y apantallamiento acústico. La columna sismoestratigráfica presentó cinco secuencias sísmicas del Pleistoceno tardío-Holoceno. Se estableció que el origen del gas es biogénico, asociado a un depósito del Holoceno Medio, desde el cual migró hasta estar en contacto con la superficie del fondo gracias a la permeabilidad de los estratos suprayacentes. El gas en la superficie del fondo fue evidenciado en sonogramas por medio de la atenuación de la señal acústica, lo que evidencia una baja cohesión de los materiales por la disminución en el esfuerzo de corte generada por las burbujas de gas. La granulometría de los sedimentos fue similar en ambos sitios, caracterizada como fango arenoso. Los sedimentos gasíferos presentaron un mayor contenido de materia orgánica. Los análisis de rayos X demostraron mayor homogeneidad en la columna de sedimentos gasíferos, respecto a los del sitio control. La medición cualitativa del gas con HPLC probó la presencia del gas metano. La riqueza específica, diversidad, equitatividad y abundancia total de organismos fue menor en el sitio con gas. Entre sitios con gas y control hubo marcadas diferencias en la estructura taxonómica. Se encontraron taxa caracterizando los sedimentos gasíferos como Stylatula darwini, Aricidea sp. y nematodes, y otros ausentes como Polydora cornuta y Monocorophium insidiosum lo que indicaría una alta sensibilidad de estas especies al gas. La diferencia en la estructura comunitaria entre sitios fue explicada por el contenido de materia orgánica de los sedimentos. Además, la estructura funcional de la comunidad bentónica en el sitio con gas presenta una mayor diversidad de roles ecológicos que en el sitio control. Se concluye que la baja estabilidad y cohesividad, así como el alto contenido de materia orgánica de los sedimentos gasíferos afecta a especies sensibles comunes en el área de estudio. Resultando en un hábitat dominado por especies oportunistas, así como, por algunos taxa que podrían utilizar indirectamente el metano como fuente de energía. / The aim of this thesis is to characterize the shallow gas deposits of the inner area of the Bahía Blanca estuary and to evaluate the effect of the gas-bearing sediments on the associated subtidal benthic communities. For this purpose, the distribution of shallow gas in the estuary was mapped through the analysis of highresolution seismic records. Based on this map, two study sites were selected (with gas and control) that only differed in the presence of gas in contact with the surface of the seabed. Acoustic methods were used to determine the stratigraphy and morphology of the site with gas and the adjacent area. In addition, the gas sediments were evaluated by means of the following analyses: grain size, organic matter content, X-rays and HPLC head space measurement. The benthic organisms of both sites were compared in terms of abundance, biomass, diversity, evenness, species richness, taxonomic and functional structure. The gas was found widely distributed in the estuary, both near and in contact with the surface of the seabed of the inner area of the Bahía Blanca estuary. It was evidenced in the form of acoustic turbidity and acoustic blanking. The seismo-stratigraphic column presented five seismic sequences of the late Pleistocene-Holocene. It was established that the gas origin is biogenic, being associated with a Middle Holocene deposit, from which it migrated until it was in contact with the surface of the seabed due to the permeability of the overlying strata. The gas in the surface of the seabed was evidenced in sonograms by means of the attenuation of the acoustic signal, which evidences a low cohesion of the materials by the decrease in the shear stress generated by the gas bubbles. The grain size of sediments was similar in both sites, characterized as sandy mud. The gas-bearing sediments presented a higher content of organic matter. X-ray analysis showed greater homogeneity in the gassy sediments column, compared to the control site. The qualitative measurement of the gas with HPLC proved the presence of methane gas. The species richness, diversity, evenness and total abundance of organisms was lower in the gas site. There were marked differences in the taxonomic structure between gas and control sites. There were found taxa characterizing the gas-bearing sediments as Stylatula darwini, Aricidea sp. and nematodes, and others absent in this site, such as Polydora cornuta and Monocorophium insidiosum, which would indicate a high sensitivity of these species to gas. The difference in community structure between sites was explained by the organic matter content of the sediments. In addition, the functional structure of the benthic community in the gas site presents a greater diversity of ecological roles than in the control site. It is concluded that the low stability and cohesiveness, as well as the high organic matter content of the gas sediments affects common sensitive species in the study area. Resulting in a habitat dominated by opportunistic species, as well as by some taxa that could indirectly use methane as an energy source.

Page generated in 0.0456 seconds