• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • 2
  • Tagged with
  • 7
  • 5
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

More transparency in bioanalysis of exocytosis : application of fluorescent false neurotransmitters in coupling methodology of electrochemistry with fluorescence microscopy at ITO microelectrodes / Bioanalyse microélectrochimique de l'exocytose vésiculaire : utilisation de faux neurotransmetteurs fluorescents dans la méthodologie de couplage de l'électrochimie avec la microscopie de fluorescence sur microélectrodes d'ITO

Liu, Xiaoqing 26 September 2016 (has links)
L’exocytose vésiculaire est une voie physiologique majeure de la communication intercellulaire. Dans ce contexte, le TIRFM (microscopie de fluorescence par réflexion totale interne) et l’ampérométrie sont aujourd'hui les deux méthodes analytiques les plus fréquemment utilisées dans l’étude de l’exocytose. En raison de la complémentarité de ces deux techniques d’analyse pour le suivi de la sécrétion exocytotique, leur combinaison pour suivre la sécrétion exocytotique a d'abord été réalisée par notre groupe en 2011. Ce couplage a permis un enregistrement simultané des signaux fluorescents et ampérométriques avec une bonne résolution spatiale et temporelle. L'inconvénient majeur de ce travail reste le chargement indépendant des sondes optique et électrochimique dans les vésicules de sécrétion, ce qui entraîne la détection d’évènements « orphelins » ampérométriques ou optiques ainsi que la faible efficacité de détection des évènements couplés. Par conséquent, dans cette thèse, nous avons tenté de mettre à profit une sonde unique à la fois fluorescente et électroactive pour suivre l’exocytose par la méthodologie couplée TIRFM/ampérométrie. Ainsi, un analogue de neurotransmetteurs monoamine primaire, la 4-(2-amino-éthyl)-6-chloro-7-hydroxy-2H-1-benzopyran-2-one (nommé 1 dans ce travail), a été synthétisé.1 présente une fluorescence forte, stable et pH-dépendante. Lorsque cette entité est excitée à 405 nm, son intensité de fluorescence est presque doublée de pH 5 (valeur intra-vésiculaire) à 7 (valeur milieu extracellulaire). De plus, des études en voltammétrie ont pu mettre en évidence que 1 est oxydable sur électrode de carbone vitreux, microélectrode à fibre de carbone et ITO (oxyde d’indium dopé à l’étain), montrant ainsi une bonne électroactivité. La pénétration cellulaire dans les vésicules de cellules BON N13 a également été démontrée, prouvant la spécificité de l’interaction entre 1 et ces vésicules équipées d’un transporteur de monoamines primaires (VMAT). L’utilisation de 1 comme sonde unique optique et électrochimique pour le suivi de l'exocytose a ensuite été validée séparément dans des cellules BON N13 par TIRFM et ampérométrie. L’enregistrement simultané par fluorescence et électrochimie en utilisant 1 comme sonde double a ensuite été réalisé dans un microdispositif constitué d’électrodes ITO conductrice et transparente. Nos résultats basés sur la sonde unique 1 montrent qu’elle semble plus adaptée que toutes les stratégies antérieures impliquant deux sondes indépendantes. Les résolutions spatiale et temporelle de cette méthode combinée ont permis d'analyser des sécrétions d’exocytose de cellules marquées par 1. Une analyse ultérieure de ces signaux couplés optique et électrochimique sera à même d’étudier la corrélation entre le comportement du pore de fusion (dynamique d'ouverture/de fermeture, stabilité..) détecté par ampérométrie et le mouvement d'une vésicule en trois dimensions (ancrage, amarrage, fusion puis retrait dans le cytoplasme) détecté par TIRFM. / Vesicular exocytosis is a ubiquitous way for intercellular communications. TIRFM (total internal reflection fluorescence microscopy) and amperometry are nowadays the two most frequently used analytical methods with complementary features for its investigation. The combination of these two analytical techniques to track exocytotic secretions was firstly achieved by our group in 2011 and this new technique was demonstrated to show both high temporal and spatial resolutions by simultaneously recording the fluorescent and amperometric signals. The major disadvantage of this former work was the independent loading of optical and electrochemical probes to the secretory vesicles, which resulted in 'sightless' amperometric or optical signals as well as low coupling efficiency. Therefore, in this thesis, we attempted to develop a unique probe with dual fluorescent/electrochemical characteristics to track exocytotic process by TIRFM/amperometry coupling technique. This is why an analog of biogenic monoamine neurotransmitters, 4-(2-aminoethyl)-6-chloro-7-hydroxy-2H-1-benzopyran-2-one hydrochloride (named as 1 in this work) was synthesized. 1 exhibited bright, stable, pH-dependent fluorescence. When excited at 405 nm, its fluorescence intensity was almost doubled with the increase of pH values from 5 (similar to that in the vesicular lumen) to 7 (similar to the extracellular medium). Furthermore, in voltammetry, 1 was demonstrated to be easily electrooxidized on GCE (glassy carbon electrode), CFE (carbon fiber electrode) and ITO (indium tin oxide) electrodes surfaces, showing good electroactivity. 1 was also shown to penetrate easily into the vesicles of BON N13 cells within 1 hour incubation, testifying its specific affinity with these VMAT-equipped (vesicular monoamine transporter) vesicles. The applications of 1 as optical and electrochemical probes for exocytosis monitoring were then separately validated in BON N13 cells by TIRFM and amperometry measurements, respectively. Simultaneous recording of fluorescent and amperometric information by using 1 dual probes loaded cells was subsequently acquired in a microfabricated device constituted by conductive and transparent ITO electrodes. Our results based on the unique probe 1 for electrochemical and fluorescent detection of exocytotic release seemed more adapted than all the previous works involving independent probes. The high spatial and temporal resolutions of this combined method also allowed analyzing consecutive exocytotic secretions as well as overlapped events in 1-stained cells. Further analysis of these two signals with complementary information will shed more light on the correlation of the fusion pore behavior (opening/closure dynamics, stability…) measured by amperometry and the motion of a secretory vesicle in three dimensions (tethering, docking, fusion and retrieval) detected by TIRFM.
2

Intégration d'électrodes dans les canaux microfluidiques : génération et détection d'espèces résolues spatialement et temporellement / Integration of electrodes in microfluidic channel : generation and detection of species with temporal and spatial resolution

Perrodin, Pierre 16 July 2014 (has links)
L’objectif de cette thèse a été d’étudier, en présence d’un écoulement laminaire, la génération et la détection électrochimiques de gradients locaux de concentration à l’intérieur de canaux microfluidiques. L’influence des paramètres géométriques et hydrodynamiques sur les réponses ampérométriques de microélectrodes a été analysée théoriquement par simulation numérique. Pour cela, plusieurs approches ont été entreprises par le biais de modèles à deux et à trois dimensions afin de résoudre l’équation du transport pour différentes géométries de dispositifs et conditions d’écoulement. Des critères ont été fixés afin de délimiter les régimes et conditions optimales de fonctionnement. Les prévisions issues des calculs ont été testées puis validées à l’aide de mesures expérimentales effectuées à partir de microdispositifs fabriqués au laboratoire. Ainsi, deux concepts innovants ont été définis pour la mise en œuvre au sein de microdispositifs de fonctions combinant microfluidique et électrochimie. Le premier est celui d’une sonde de concentration à très haute résolution temporelle. Le second est la génération d’un gradient linéaire de concentration sur la section d’un canal microfluidique rectangulaire. / The aim of this thesis was to study the electrochemical generation and electrochemical detection of local concentration gradients within microfluidic channels in presence of a laminar flow. The influence of geometric and hydrodynamic parameters on the amperometric responses of microelectrodes was analyzed theoretically by means of numerical simulations. Several approaches were undertaken using two-dimensional and three-dimensional models in order to solve the transport equation according to the device geometries and flow conditions. Criteria were set to delineate the operating regimes and optimal conditions. Predictions from calculations were tested and validated experimentally using microdevices fabricated in the laboratory. Therefore, two innovative concepts were defined for the implementation of functions within microdevices combining microfluidics and electrochemistry. The first one is a probe of concentration leading to very high temporal resolution. The second one is the generation of a linear concentration gradient over the cross section of a rectangular microfluidic channel.
3

High-performance electrochemical detection of reactive oxygen/nitrogen species inside microfluidic devices : application for monitoring oxidative stress from living cells / Détection électrochimique à haute performance d’espèces réactives de l’oxygène et de l’azote à l’Intérieur de dispositifs microfluidiques : application au stress oxydant de cellules vivantes

Li, Yun 17 September 2014 (has links)
Avec les avantages intrinsèques de l'électrochimie et les progrès sans précédent dans l'instrumentation, les microélectrodes jouent un rôle de premier plan dans l'analyse du comportement de cellules vivantes. Aujourd'hui, la microfluidique gagne également en popularité en raison de la possibilité d'effectuer l'ensemble de l'expérience de bioanalyse dans un dispositif automatisé. Dans cette thèse, la fabrication de microbandes Pt/noir-Pt a été optimisée pour détecter les espèces ROS/RNS durant le stress oxydant. Celles-Ci ont été intégrées dans des microdispositifs en PDMS-Verre afin d'analyser la libération de quatre composés clés (i.e., H2O2, ONOO-, NOo, et NO-2) à partir de populations de cellules. Les performances analytiques ont été évaluées suivant la géométrie des dispositifs et les conditions hydrodynamiques. Le contrôle des réponses électrochimiques par le transport de masse a été validé par comparaison avec des prédictions théoriques. Des détections simultanées de ROS/RNS libérées par des macrophages ont ensuite été réalisées sous deux configurations différentes de dispositifs. Des résultats reproductibles et statistiquement pertinents ont été obtenus en seulement quelques expériences. Ces microdispositifs permettent de caractériser facilement le comportement moyen de populations de cellules. Cette étude préalable ouvre la voie à un très large champ d'applications bioanalytiques intégrant des détections électrochimiques à haut débit pour le suivi de cellules vivantes. / With intrinsic benefits of electrochemistry and unprecedented progress in instrumentation, microelectrodes are playing prominent roles in the analysis of living cells behaviors. Nowadays, microfluidics also gains in popularity due to the feasibility of performing the entire bioanalytical experiment within an automated device. In this thesis, fabrication of Pt/Pt-Black microband electrodes was thus optimized to detect ROS/RNS species during oxidative stress. They were integrated into PDMS-Glass microdevices in order to analyze four key compounds (i.e., H2O2, ONOO–, NO•, and NO–2) released from cells populations. High analytical performances were first evidenced according to the devices geometry and hydrodynamic conditions. The control of the electrochemical responses by mass transport was validated through comparison with theoretical predictions. Simultaneous detections of ROS/RNS release from macrophages were then carried out under two different configurations of microdevices. Reproducible and statistically relevant results were obtained within only few experiments. These microdevices allow for easy characterizations of average behaviors of cells populations. This study paves the way to a very broad field of bioanalytical applications integrating electrochemical detections for high-Throughput monitoring of living cells
4

Détection ampérométrique d'Escherichia coli (totaux et producteurs de BLSE) et d'Enterococcus spp. dans les systèmes de traitement des eaux usées et les eaux de baignade / Amperometric detection of Escherichia coli (totals and extended spectrum beta lactamase producing strains) and Enterococcus spp. in wastewater treatment plants and bathing waters

Chantemesse, Benoît 04 December 2017 (has links)
Les eaux traitées rejetées par les stations de traitement des eaux usées (STEU) et les effluents d’élevages sont à l’origine de contaminations des milieux aquatiques et des sols agricoles par des micro-organismes fécaux d’origines humaine et animale. Les eaux contaminées, et en particulier les eaux de baignade, peuvent présenter un risque sanitaire pour les humains si les concentrations en micro-organismes fécaux sont élevées, indiquant la présence potentielle de souches pathogènes et/ou résistantes aux antibiotiques. Les sols et les productions végétales peuvent également être contaminés par ces micro-organismes fécaux lors de l’épandage d’eaux traitées de STEU recyclées pour l’irrigation des cultures. Il est donc obligatoire de contrôler la qualité microbiologique des eaux de baignade et des eaux traitées de STEU pour limiter les risques sanitaires.D’un point de vue réglementaire, les contrôles de la qualité microbiologique des eaux traitées et des eaux de baignade sont basés sur la quantification de deux indicateurs bactériens de contamination fécale que sont les Escherichia coli (E. coli) et les entérocoques intestinaux (EI). Cependant, les méthodes disponibles actuellement présentent un voire plusieurs des inconvénients suivants : temps de réponse élevé, coût important, complexité de mise en œuvre, utilisation ex-situ, analyse d’un seul indicateur.Pour pallier ces inconvénients, le premier objectif de la thèse a été la mise au point d’une méthode de détection ampérométrique des E. coli et des EI, via la mesure d’activités enzymatiques spécifiques à l’aide de capteurs sérigraphiés à usage unique. Le travail réalisé a mis en évidence que la méthode ampérométrique permet d’obtenir des dénombrements en E. coli et en EI comparables à ceux obtenus avec les méthodes normalisées ISO 9308-3 et 7899-1 lors de l’analyse d’échantillons d’eaux traitées de STEU tout en offrant un temps d’analyse beaucoup plus court (en 4 à 6 h contre 36 à 72 h). De plus, l’application de la méthode à l’analyse d’échantillons d’eaux de baignade a permis de montrer que, contrairement aux 36 h minimum nécessaires avec les méthodes normalisées, la détection ampérométrique permet de déterminer en seulement 7 h si les échantillons respectent les normes de qualité sanitaires pour les eaux de baignade.Dans un second temps, une méthode de quantification ampérométrique des souches d’E. coli producteurs de β-lactamase à spectre étendu (BLSE) a été mise au point et appliquée à l’analyse d’échantillons d’eaux de STEU. Les résultats ont montré que les dénombrements ampérométriques obtenus en seulement 4 - 5 h étaient très proches de ceux fournis par une méthode de dénombrement sur milieux de culture sélectifs après un délai de 24 h. De plus, ce travail a permis de confirmer le rejet de souches productrices de BLSE par la majorité des STEU et ce, qu’elles reçoivent ou non des effluents hospitaliers.En conclusion, la méthode de détection ampérométrique des E. coli et des EI proposée autorise une détermination plus rapide de la qualité sanitaire des eaux traitées de STEU et des eaux de baignade que les méthodes normalisées qui servent actuellement de références. De plus, la détection et le dénombrement de souches d’E. coli producteurs de BLSE dans les eaux de STEU permet d’évaluer leur impact dans la dissémination environnementale de souches résistantes aux antibiotiques. L’avenir des outils électrochimiques étant prometteur, la poursuite de ce travail consistera à développer un dispositif d’analyse portable pour des applications sur le terrain. / Treated wastewaters discharged from wastewater treatment plants (WWTP) and livestock effluents are the main sources of contamination of aquatic environments and of agricultural soils by human and animal fecal micro-organisms. Contaminated waters, especially bathing waters, may present a sanitary risk for humans if the concentrations of fecal micro-organisms are high, thus indicating the potential presence of pathogenic and/or antibiotic resistant strains. Soils and crops also can be contaminated by these micro-organisms when treated wastewaters are used to irrigate cultivated soils. Consequently, microbiological quality controls are mandatory for bathing waters and treated wastewaters to manage and limit sanitary risks.According to the regulation, the microbiological controls of treated wastewaters and bathing waters rely on the quantification of two fecal indicator bacteria: Escherichia coli (E. coli) and intestinal enterococci (IE). However, the methods currently available have one or more of the following disadvantages, i. e. long response time, high cost, complexity of implementation, ex-situ use, analysis of a single indicator.To overcome these disadvantages, the first objective of the thesis was the development of an amperometric method for the detection of E. coli and IE, via the measurement of specific enzymatic activities using single-use screen-printed sensors. It was demonstrated that the amperometric method allowed to enumerate E. coli and IE in treated wastewaters samples and that the results were comparable to those obtained with the ISO 9308-3 and 7899-1 standardized methods, while offering a much shorter analysis time (in 4 to 6 h against 36 to 72 h). Moreover, the application of the amperometric method to the analysis of bathing water samples showed that contrary to the minimum 36 hours required with standardized methods, the amperometric detection provided answers regarding the sanitary quality standards for bathing waters within only 7 hours.Then in a second time, we developed an amperometric method to quantify extended-spectrum β-lactamase (ESBL)-producing E. coli in wastewaters samples. The results showed that amperometric counting obtained in only 4 - 5 h were very close to those provided by the enumeration on selective culture medium obtained after a delay of 24 h. In addition, this work confirmed the release of ESBL-producing strains by most of WWTP, whether or not they received hospital effluents.In conclusion, the proposed amperometric method to detect E. coli and IE provided more rapidly results regarding the sanitary quality of treated wastewaters of WWTP and bathing waters than the standardized methods currently used as references. Moreover, the amperometric detection and enumeration of ESBL-producing E. coli in the wastewaters of WWTP allowed to monitor their role in the environmental dissemination of antibiotic-resistant strains. Owing to the advantages of the developed electrochemical tools, further work will consist in developing a portable analysis device for field applications.
5

Développement de biocapteurs pour la détermination de substances biologiquement actives / Development of biosensors for the determination of biologically active substances

Kucherenko, Ivan 03 June 2016 (has links)
Les biocapteurs sont des moyens d’analyse en plein essor à la fois rapides, sélectifs et peu coûteux applicables à des domaines extrêmement variés (environnement, santé, agroalimentaire,…). Dans ce type d’outil, un élément sensible de nature biologique (anticorps, enzyme, microorganisme, ADN…) doté d’un pouvoir de reconnaissance pour un analyte ou un groupe d’analytes est associé à un transducteur pouvant être de type électrochimique, optique ou thermique.Dans ce travail, nous nous sommes intéressés au développement de trois biocapteurs pour la détection de substances biologiquement actives. Le premier permet la détermination simultanée de l’adénosine triphosphate (ATP) et du glucose par ampérométrie, le deuxième celle de la créatine kinase, et le troisième est un biocapteur conductimétique pour la quantification de l’ATP. Dans les deux premiers biocapteurs, deux enzymes (l’hexokinase et la glucose oxydase) sont immobilisées à la surface de microélectrodes constituées d’un disque de platine. Le troisième biocapteur est basé sur l’immobilisation de l’hexokinase sur des microélectrodes interdigitées en or. L’immobilisation est réalisée dans tous les cas par co-réticulation des enzymes en présence d’albumine de sérum bovin à l’aide de glutaraldehyde. Les caractéristiques analytiques des biocapteurs ont été déterminées et différentes procédures ont été développées pour l’analyse d’échantillons réels. Les biocapteurs ont pu être appliqués avec succès à la quantification de l’ATP, du glucose et de la créatine kinase dans des préparations pharmaceutiques et du sérum sanguin / Biosensors are rapid, selective and inexpensive devices that combine a biological recognition element, the so-called bioreceptor (e.g. enzymes, antibodies, DNA or microorganisms) to a physical transducer (e.g. electrochemical, optical, thermal or piezoelectrical). They can be used to detect one specific analyte or one family of analytes for a wide range of applications (e.g. environment, food, health). In this work, the detection of biologically active substances was targeted. A biosensor system for simultaneous determination of adenosine triphosphate (ATP) and glucose, a biosensor for creatine kinase analysis, and a novel conductometric biosensor for ATP determination were developed. In the first two biosensors, two enzymes (hexokinase and glucose oxidase) were immobilized at the surface of platinum disc microelectrodes for amperometric detection. The third biosensor was based on hexokinase immobilized onto gold interdigitated microelectrodes for conductometric detection. In all cases, the enzymes were co-immobilized with bovine serum albumin by cross-linking using glutaraldehyde. Analytical characteristics of the biosensors were determined and different procedures were developed for real samples analysis. The biosensors could be successfully applied to the determination of ATP, glucose, and creatine kinase in pharmaceutical samples and blood serum
6

Développement d'électrodes sélectives pour l'analyse de composés d'intérêt pharmaceutique : Antipaludéens et halogénures

Kimbeni Malongo, Trésor 25 June 2008 (has links)
RESUME Le travail de thèse porte sur le développement d’électrodes sélectives originales et performantes pour l’analyse de composés d’intérêt pharmaceutique. La partie introductive traite des notions relatives à l’électrochimie mais également de notions sur les molécules médicamenteuses étudiées, en l’occurrence les principes antipaludéens et l’iode. La partie expérimentale se subdivise en deux parties distinctes selon le type d’électrodes sélectives auxquelles font appel les techniques électrochimiques. La première partie concerne l’élaboration, la caractérisation et l’application des électrodes potentiométriques à membrane polymérique incluant une paire d’ions et sélectives à diverses molécules organiques pharmacologiquement actives (antipaludéens). Leur application aussi bien en analyse pharmaceutique qu’en cinétique de dissolution est décrite. La deuxième partie est consacrée à l’élaboration d’un type de senseur ampérométrique original à pâte de carbone à base d’argent micronisé ou colloïdal et à la comparaison de ses performances avec l’électrode d’argent métallique. L’intérêt analytique est mis en évidence par la détermination quantitative des iodures. Les différents aspects susceptibles d’influencer leur comportement, dont la nature des agents précipitants (tétraphénylborate de sodium et le tétrakis (4-chlorophényl) borate de potassium) et de plastifiants ont été investigués. Les bonnes performances des ces électrodes en analyse quantitative ont permis d’explorer les possibilités de leur utilisation à l’étude de la cinétique de dissolution. L’ampérométrie à électrode à pâte de carbone modifiée à base d’argent à l’échelle micronisée (35% m/m) couplée à la chromatographie liquide ionique s’est avérée très sensible vis-à-vis des iodures en particulier et des halogénures en général. Les facteurs susceptibles d’influencer les grandeurs de séparation et la réponse de l’électrode ont été investigués et l’exploitation du signal ampérométrique permet le dosage sélectif et rapide de faibles concentrations en iodures. Les informations fournies par les mesures réalisées en voltampérométrie cyclique à l’aide des mêmes électrodes permettent une bonne compréhension mécanistique quant au mode de détection ampérométrique évitant ainsi toute confusion à ce sujet et permettant l’optimisation du processus de détection. ------------------------------------------------ ABSTRACT This thesis describes the development of original and high performance selective electrodes for the analysis of several pharmaceutical compounds. The introduction describes the pharmaceutical compounds of interest (antimalarial drugs and iodine) and provides an overall understanding of the electrochemical groundwork pertaining to their analysis. The experimental aspect of the thesis is divided into two parts, each according to the type of electrode and electrochemical technique used for the analysis. The first part describes the design, characterization, and application of polymer membrane based ion selective potentiometric electrodes. Selectivity was provided by including ion pairs of several antimalarial drugs into the membrane. The feasibility of use of these electrodes in pharmaceutical analysis as well as in dissolution trials is also described in this part. The second part describes the design of an original silver-modified carbon paste amperometric sensor and compares its performances to those of a plain metallic silver electrode. The electrode has been modified by silver microparticles or by silver nanoparticles. Quantitative iodine determination serves to prove the usefulness of this new sensor in analytical chemistry. Different aspects, such as the nature of the counter ions (sodium tetraphenylborate and potassium tetrakis (4-chlorophenyl) borate) and the plastifying agents that are likely to influence electrode behaviour have been investigated. Since the electrodes have been shown to perform well in quantitative analysis, the possibility of use in dissolution trials was explored. Micronized silver-modified carbon paste electrode (35% Ag m/m) coupled to anionic-exchange liquid chromatography with amperometric detection was shown to be very sensitive with regards to the assay of halogenides in general and iodide in particular. After having investigated the various factors likely to influence chromatographic separation and electrode response, it was shown that the sensor could be used to rapidly and selectively determine low iodide concentrations in complex samples. Cyclic voltammetric analysis provided information concerning the mechanisms allowing amperometric detection, thus allowing an optimisation of the detection procedures.
7

Développement d'électrodes sélectives pour l'analyse de composés d'intérêt pharmaceutique: antipaludéens et halogénures

Kimbeni Malongo, Trésor 25 June 2008 (has links)
RESUME<p><p>Le travail de thèse porte sur le développement d’électrodes sélectives originales et performantes pour l’analyse de composés d’intérêt pharmaceutique. <p><p> La partie introductive traite des notions relatives à l’électrochimie mais également de notions sur les molécules médicamenteuses étudiées, en l’occurrence les principes antipaludéens et l’iode.<p><p> La partie expérimentale se subdivise en deux parties distinctes selon le type d’électrodes sélectives auxquelles font appel les techniques électrochimiques.<p><p> La première partie concerne l’élaboration, la caractérisation et l’application des électrodes potentiométriques à membrane polymérique incluant une paire d’ions et sélectives à diverses molécules organiques pharmacologiquement actives (antipaludéens). Leur application aussi bien en analyse pharmaceutique qu’en cinétique de dissolution est décrite.<p><p> La deuxième partie est consacrée à l’élaboration d’un type de senseur ampérométrique original à pâte de carbone à base d’argent micronisé ou colloïdal et à la comparaison de ses performances avec l’électrode d’argent métallique. L’intérêt analytique est mis en évidence par la détermination quantitative des iodures.<p><p> Les différents aspects susceptibles d’influencer leur comportement, dont la nature des agents précipitants (tétraphénylborate de sodium et le tétrakis (4-chlorophényl) borate de potassium) et de plastifiants ont été investigués.<p>Les bonnes performances des ces électrodes en analyse quantitative ont permis d’explorer les possibilités de leur utilisation à l’étude de la cinétique de dissolution.<p><p> L’ampérométrie à électrode à pâte de carbone modifiée à base d’argent à l’échelle micronisée (35% m/m) couplée à la chromatographie liquide ionique s’est avérée très sensible vis-à-vis des iodures en particulier et des halogénures en général. Les facteurs susceptibles d’influencer les grandeurs de séparation et la réponse de l’électrode ont été investigués et l’exploitation du signal ampérométrique permet le dosage sélectif et rapide de faibles concentrations en iodures. Les informations fournies par les mesures réalisées en voltampérométrie cyclique à l’aide des mêmes électrodes permettent une bonne compréhension mécanistique quant au mode de détection ampérométrique évitant ainsi toute confusion à ce sujet et permettant l’optimisation du processus de détection.<p>------------------------------------------------<p>ABSTRACT<p><p>This thesis describes the development of original and high performance selective electrodes for the analysis of several pharmaceutical compounds. <p><p>The introduction describes the pharmaceutical compounds of interest (antimalarial drugs and iodine) and provides an overall understanding of the electrochemical groundwork pertaining to their analysis.<p><p>The experimental aspect of the thesis is divided into two parts, each according to the type of electrode and electrochemical technique used for the analysis.<p>The first part describes the design, characterization, and application of polymer membrane based ion selective potentiometric electrodes. Selectivity was provided by including ion pairs of several antimalarial drugs into the membrane. The feasibility of use of these electrodes in pharmaceutical analysis as well as in dissolution trials is also described in this part.<p><p>The second part describes the design of an original silver-modified carbon paste amperometric sensor and compares its performances to those of a plain metallic silver electrode. The electrode has been modified by silver microparticles or by silver nanoparticles. Quantitative iodine determination serves to prove the usefulness of this new sensor in analytical chemistry.<p><p>Different aspects, such as the nature of the counter ions (sodium tetraphenylborate and potassium tetrakis (4-chlorophenyl) borate) and the plastifying agents that are likely to influence electrode behaviour have been investigated. <p><p>Since the electrodes have been shown to perform well in quantitative analysis, the possibility of use in dissolution trials was explored.<p><p>Micronized silver-modified carbon paste electrode (35% Ag m/m) coupled to anionic-exchange liquid chromatography with amperometric detection was shown to be very sensitive with regards to the assay of halogenides in general and iodide in particular. After having investigated the various factors likely to influence chromatographic separation and electrode response, it was shown that the sensor could be used to rapidly and selectively determine low iodide concentrations in complex samples. Cyclic voltammetric analysis provided information concerning the mechanisms allowing amperometric detection, thus allowing an optimisation of the detection procedures.<p> / Doctorat en Sciences biomédicales et pharmaceutiques / info:eu-repo/semantics/nonPublished

Page generated in 0.0629 seconds