• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 94
  • 57
  • 16
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 204
  • 78
  • 60
  • 32
  • 31
  • 28
  • 20
  • 17
  • 17
  • 15
  • 14
  • 14
  • 13
  • 12
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
201

Efeito da umidificação dos gases anestésicos nas propriedades físicas e transportabilidade do muco respiratório durante anestesia geral / Effects of inspired gases humidity on respiratory mucus in patients under general anesthesia

Claudia Simeire Albertini Yagi 09 October 2006 (has links)
Introdução: Em pacientes sob intubação endotraqueal os mecanismos fisiológicos de climatização do ar inspirado são anulados. Durante anestesia geral, quando os gases inspiratórios são ofertados secos e frios, a manutenção da umidade das vias aéreas é condição importante para prevenção de lesões da mucosa respiratória e ressecamento das secreções. Os sistemas de anestesia possuem propriedades de umidicação inerentes, decorrentes do sistema respiratório circular e a presença do absorvedor de CO2. Entretanto, os níveis de umidificação, durante a anestesia, dependem de vários fatores incluindo o tipo de ventilador anestésico, montagem do sistema respiratório e o fluxo de gás fresco utilizado. Porém não há dados na literatura que tenham investigado o efeito nos níveis de umidade do gás inspirado nas propriedades físicas e de transportabilidade do muco respiratório. Objetivo: Avaliar os níveis de Temperatura (T), umidade absoluta (UA) e umidade relativa (UR) do ar inspirado durante anestesia geral oferecidos pelo sistema circular valvular com absorção de CO2 e com a adição do HME em dois tipos de ventiladores (Dräger e Takaoka). Avaliar os efeitos do HME sobre os níveis de Temperatura e Umidade dos gases inspirados ofertados pelos dois equipamentos. Avaliar o impacto da umidade sobre as propriedades físicas e de transportabilidade do muco respiratório. Método: Foram selecionados 44 pacientes da Clínica Cirúrgica II do Departamento de Gastroenterologia do HCFMUSP com indicação de cirurgia abdominal eletiva e anestesia geral com duração superior a 4 horas. Os pacientes foram alocados em 4 grupos conforme o tipo do ventilador utilizado (Dräger ou Takaoka) e a presença ou ausência do HME. O muco respiratório e os dados de temperatura, UR e UA do gás ofertado foram coletados logo após a intubação endotraqueal, e a cada duas horas até o final da cirurgia. A análise do muco respiratório foi realizada através dos seguintes métodos: Transportabilidade mucociliar (MCT), em palato de rã; Transportabilidade pela tosse (TT), através da máquina simuladora da tosse e as propriedades de superfície, através do Ângulo de contato (AC). Resultado: O ventilador Dräger foi significantemente mais efetivo em ofertar níveis mais altos de T, UA e UR comparado ao ventilador Takaoka. A adição do HME aumentou a T e UA nos dois equipamentos. A UR aumentou somente no ventilador Takaoka. Houve um aumento do TMC e da TT no grupo que apresentou níveis mais altos de umidade (i.e. Dräger + HME). O AC não mostrou diferenças entre os quatro grupos. A análise longitudinal mostrou que o TMC foi positivamente afetado com o aumento da UA e UR. A TT foi positivamente afetada com a adição do HME. Conclusão: Nossos resultados mostram que o ventilador Dräger produziu níveis significantemente mais altos de umidade comparados ao ventilador Takaoka e que a adição do HME aumentou os níveis de umidade nos dois equipamentos estudados. Os equipamentos anestésicos e a adição do HME afetaram os níveis de umidade ofertados ao paciente durante a anestesia geral, e essas mudanças influenciaram a transportabilidade do muco respiratório / Background: In patients who are intubated, the natural mechanism of gas climatization by the nose and the upper airway is bypassed. During anesthesia, when the inspiratory gases are cold and dry, humidification of gases is recommended to prevent drying of the mucosal epithelium and respiratory secretions. The anesthesia systems have inherent humidifying properties as a result of the valvular rebreathing of some of the expired humidity and of the production of water in the CO2 absorber. However, the level of moisture in anesthetic ventilation is critically dependent on several factors that include the equipment, the arrangement of the circle breathing system and the fresh gas flow. To date the effect of humidity on respiratory mucus properties and transportability was not investigated. Objectives: The objective of this study was to measure the humidity and temperature of the inspired gas from a circle absorber system in two different ventilators (Dräger and Takaoka) and the effect of a heat and moisture exchanger (HME) on the inspired gas. Furthermore, we also evaluated the impact of humidity on in vitro mucus transportability and physical properties. Methods: We studied 44 patients with no pulmonary disease scheduled for elective surgery that were randomly allocated in four groups according to the anesthetic equipment (Dräger or Takaoka) and the absence or presence of HME. Respiratory mucus was collected and Temperature (T), absolute humidity (AH), relative humidity (RH) of inspired gases were recorded immediately after intubation (T0) and every 2 hours. In vitro respiratory mucus was studied by mucociliary transportability (MCT) by the frog palate method; cough clearance (CC) by the cough equipment, and contact angle (CA) by direct observation. Results: Dräger equipment delivered significantly higher levels of RH and AH when compared to Takaoka. The addition of HME increased AH and T in both equipments. RH was improved only in the Takaoka equipment. MCT, CC showed a non-significant trend to be higher in the group that provided the highest humidity (i.e Dräger + HME). CA did not change among groups. Longitudinal analysis showed that MCT was positively affected by an increase in AH and RH. CC was positively affected by the addition of HME. Conclusion: Our results showed that Dräger equipment was more effective in humidifying anesthetic gas than Takaoka. The performance of both equipments was improved when HME was added. The anesthetic equipment and the addition of HME affect the humidity delivered to the patient that in turn influences in vitro respiratory mucus transportability
202

Impacto farmacoeconômico da implantação do método de dispensação de drogas em forma de kit em procedimentos cirúrgicos e anestésicos / The drug dispensation method implementation impact of Pharmacy-economic in kit on anesthetic and surgery procedure

Elisangela Maria Santos Mattos 06 April 2006 (has links)
Proposta: O hospital é parte integrante de um sistema coordenado de saúde, cuja função é a prestação de serviços. Os administradores hospitalares preocupam-se em obter o menor custo possível e maximizar a qualidade. Como o custo hospitalar tem uma parcela importante representada pelo consumo de materiais e medicamentos, sendo a farmácia o setor responsável pelo controle, estoque e dispensação, o profissional farmacêutico tem-se aprimorado profissionalmente e desenvolvido pesquisas e estudos, para reformular suas atividades básicas e retomar algumas funções primárias como a farmacoeconomia, a fim de adequar-se as novas exigências. É relevante neste contexto o sistema de distribuição de medicamentos, que se iniciou com a dose coletiva, cujos principais problemas era o aumento do potencial de erros de medicação, as perdas econômicas decorrentes da falta de controles, e o tempo excessivo gasto pela enfermagem para separar a medicação, em vez de dar assistência aos pacientes. Depois avançou para dose individualizada, que além de minimizar e/ou extinguir todas as desvantagens da dose coletiva, apresentava um controle mais efetivo do consumo dos medicamentos, aumentando a integração do farmacêutico com a equipe de saúde, sendo sua principal desvantagem, o aumento das necessidades de recursos humanos e infra-estrutura da Farmácia Hospitalar. E por último a dose unitária, originada da dose individualizada, que tem como principais objetivos racionalizar a terapêutica, diminuir custos sem reduzir a qualidade da dispensação; e garantir que os medicamentos prescritos cheguem ao paciente de forma segura e higiênica, assegurando a eficácia do esquema terapêutico prescrito. Após associar os conceitos descritos acima, a farmácia do Centro Cirúrgico do Instituto Central do Hospital das Clínicas da Faculdade de Medicina da USP propôs-se a identificar o elenco representativo de produtos, e utilizar estes grupos de medicamentos, na elaboração, ampliação, e experimentação do sistema de dispensação de kit. Esta nova alternativa pretende atingir como os dois principais benefícios a melhor utilização de recursos econômicos e a elevação da qualidade de assistência prestada ao paciente e equipe multiprofissional. Método: O método de pesquisa utilizado foi um estudo de caso qualitativo/quantitativo, sendo o mesmo realizado no Centro Cirúrgico do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, no período de 12/05/2002 a 22/07/2002. Foram escolhidas como amostra as dez salas do bloco III, onde pudemos acompanhar procedimentos de médio e grande porte de determinadas especialidades médicocirúrgicas. O estudo foi dividido em três etapas, sendo as duas primeiras experimentais, e a terceira apenas de análise e interpretação dos achados. Foi realizado o mapeamento do elenco de medicamentos disponibilizado (seja nos carrinhos de drogas, nos kits e nas solicitações extra) e o levantamento do consumo de três dias de funcionamento de cada sala cirúrgica do Bloco III, nas duas etapas experimentais. Na primeira etapa - pré kit - o levantamento foi realizado através da verificação do elenco e das quantidades contidas nos carros de parada e anestesia de cada uma das salas, às 06h30min da manhã antes do início das cirurgias e no final da tarde após o término da última, assim, delimitando o consumo/dia/sala. Estes levantamentos eram feitos em dias aleatórios para não induzir a equipe médica ou a enfermagem em modificar seu consumo. Na segunda etapa - pós kit - realizou-se o levantamento dentro da unidade farmacêutica através da análise dos documentos de dispensação do kit e notas de débito, onde estavam relacionadas as quantidades de medicamentos utilizadas e solicitadas pela auxiliar de enfermagem durante a cirurgia. A confirmação desta documentação era feita através da conferencia do kit e devolução de medicamentos extra. Os carros de medicamentos não estavam mais sendo utilizados, apenas os kits e os medicamentos extra, que pela rotina estabelecida deviam ser devolvidos após o término de cada cirurgia, não permanecendo nada em sala entre uma cirurgia e outra. Após o fechamento dos dois levantamentos pré e pósimplantação do kit procedeu-se às seguintes análises dos resultados: Comparação do consumo de medicamentos por sala/dia; Relação de preço de cada medicamento utilizado; Cálculo do valor total gasto por sala/dia; Comparação do valor gasto por sala/dia. Vale assinalar que: Os anestésicos inalatórios não entraram no levantamento dos medicamentos utilizados nas cirurgias, pois comportam frações diferentes para cada paciente; No primeiro dia de mapeamento (pré e pós) das salas cirúrgicas, os medicamentos vencidos encontrados foram recolhidos e considerados como consumidos. Resultados: Não houve críticas nem reclamações em relação ao novo sistema implantado. Quantitativamente, houve uma redução de aproximadamente 47% no estoque inicial, 54% nas solicitações extras e 30,4% no consumo de medicamentos, com impacto muito relevante sobre os custos. Conclusões: Foi viável e benéfica a prática de implantação dos kits, pois houve redução de aproximadamente 60% nos gastos, estimados pelo preço de medicamentos, traduzindo menores perdas e desperdícios. / Purpose: The hospital a integrant of a health coordinated system, which duty is offer services. The hospital administrators\' worry is get the lowest cost as possible and increasing the quality. As the hospital cost has an important installment represented by the medicine and materials consumed, and the pharmacy being the control responsible section, storage and dispensation, the pharmacist has improving professionally and developing researches and studies, in order to reformulate ones basics activities and recover some primary functions such as pharmaco economy, in order to adequate the new demands. The medicine distribution system is relevant in this context, which has started with a collective dose, which the main problems were the medicine error increased, the economic losses because of the lack of control, and the excessive expenses by the nurse ring in order to sort out the medicine, instead of patient care. Then it upgrade to the individual dose, which has not only decrease and /or extinguishes all the disadvantage of collective dose, presented a more effective control of the medicine consume, increasing the pharmacist integration along with health group, being the main disadvantage, the increase of Hospital Pharmacy infrastructure and human recourse need. And the one dose being the last one, being a derivation from the individual dose, which has as the main targets rationalize the therapy, decrease the costs without reducing the dispensation quality; and guaranty that the prescribed medicine reach the patient in a hygienic and safe fashion, guarantying the efficacy of the prescribed therapeutic scheme. After having connect the above described concepts, the Surgery Room of Instituto Central do Hospital das Clínicas da Faculdade de Medicina da USP purpose identify a representative product group, and use these medicine group, on the kit dispensation system elaboration, increase , and experiment. This new alternative intend to hit as the two main benefits which are the better use of economic resources and increasing the assistance quality giving to the patient and to the multi professional team. Method: The used research method applied was a qualitative/quantitative study case, where it was applied at the Centro Cirúrgico do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, from 12/05/2002 to 22/07/2002. Were chosen as samples the ten surgey rooms of Block III, where we could follow big and medium port procedures of specific medical surgery specialties. The study was divided into three steps, where the first two experiments, and the third one was only analyses and comprehension of found. From the available medicine group mapping was taken (which means ones in the drug trolleys, at the kits and the extra solicitations) and the inventory of three day consumptions of each surgery room at the Block III, at the two experimental steps. At the first step - pre kit - the inventory was taken through a verification of the group the quantities which were in the drug emergency trolley and anesthesia of each room, at 06:30 min a.m. before the surgeries starting and at the late afternoon after the last surgery happened, so, determining the consumption/ day/room. These inventories were chosen in random days way in order not to prompt the medical or the nursing group to modify their consumption. At the second step - post kit - the inventory was taken in the pharmacy unit through out of a kit dispensation documents analyses and debit note, which were listed the medicine amount used and from the nurse asked for during the surgery. This document confirmation was done through out of the kit checking and the extra medicine return. The medicine trolley were not use any more, only the kits and the extra medicine, which through the established routine should be returned after each surgery ended, and nothing was left in the surgery room between surgeries. The analyses of the results were taken right after the closing of the two research pre and post kit implementation: Medicine consume comparison by room/day; Listing the price of each medicine used; Total expenses calculated by room/day; Comparison of expenses by room/day. Is worthwhile note that: The inhale ting anesthetic are not considered on the used medicine inventory used at the surgery, because it holds different fractions for each patient; At the first surgery room mapping day (pre and post) the out of day medicine were took away and considered as used. Results: There were no criticism nor complaints related to implemented new system. Quantitatively, there was a decrease of 47% on the initial stock, 54% at the extra solicitations and 30,4% at the medicine consumption, with a very related impact on the costs. Conclusions: The implementation of the kits was totally viable because there was about 60% costs reduction, estimated by the medicine price, presenting less losses and wastings.
203

INFILTRAÇÃO DE DIFERENTES SUBSTÂNCIAS OU AGULHAMENTO À SECO EM DOR MIOFASCIAL UMA REVISÃO SISTEMÁTICA / DIFFERENT SUBSTANCES INJECTIONS OR DRY NEEDLING IN MYOFASCIAL PAIN: A SYSTEMATIC REVIEW

Machado, Eduardo 17 June 2015 (has links)
The temporomandibular myofascial pain presents a major challenge in the diagnosis of temporomandibular disorders. Due to the characteristics of this condition, intramuscular injection procedures are often needed for adequate control of symptoms and treatment. Thus, the aim of this study was to evaluate the effectiveness of injection with different substances or dry needling in temporomandibular myofascial pain. The study design consisted of a systematic review of randomized clinical trials and research databases consulted were: Pubmed, EMBASE, CENTRAL/Cochrane, Lilacs, Scopus and Web of Science until October 2014. The selection of studies was carried out by two independent reviewers, who applied eligibility criteria to obtain the final sample of primary studies. After application of the inclusion criteria were selected fifteen studies. Due to the heterogeneity of the primary studies it was not possible to perform a meta-analysis. The narrative analysis of the results showed that most of the studies had methodological limitations and biases that have compromised the quality of its findings. Thus, there is a need of conducting further randomized clinical trials, with follow-up and larger samples, to evaluate the real effectiveness of the technique and evaluated substances. / A dor miofascial temporomandibular apresenta um grande desafio diagnóstico dentro das Disfunções Temporomandibulares. Devido às características dessa condição, procedimentos de infiltração intramuscular muitas vezes são necessários para o adequado controle e tratamento dos sintomas. Assim, o objetivo desse estudo é avaliar a efetividade de infiltrações com diferentes substâncias ou agulhamento à seco em dor miofascial temporomandibular. O delineamento do estudo consistiu em uma revisão sistemática de ensaios clínicos randomizados e as bases de pesquisa consultadas foram: Pubmed, EMBASE, CENTRAL/Cochrane, Lilacs, Scopus e Web of Science no período até outubro de 2014. A seleção dos estudos foi realizada por dois avaliadores independentes, que aplicaram critérios de elegibilidade para a obtenção da amostra final de estudos primários. Após a aplicação dos critérios de inclusão quinze estudos foram selecionados. Devido à heterogeneidade dos estudos primários não foi possível realizar uma meta-análise. A análise narrativa dos resultados mostrou que a maioria dos estudos apresentava limitações metodológicas e vieses que comprometeram a qualidade de seus achados. Assim, existe a necessidade da condução de novos ensaios clínicos randomizados, com tempo de acompanhamento e amostras maiores, para avaliar a real efetividade da técnica e das substâncias avaliadas.
204

Monitorização da glicemia em tempo real durante cirurgia odontológica ambulatorial em portadores de diabetes mellitus tipo 2: estudo comparativo entre anestésico local sem e com vasoconstritor / Glucose monitoring in real time during outpatient dental surgery in patients with type 2 diabetes mellitus: a comparative study of local anesthetics with and without epinephrine

Marcela Alves dos Santos 10 October 2013 (has links)
INTRODUÇÃO: A segurança da administração de anestésicos locais com vasoconstritor em pacientes diabéticos submetidos à cirurgia oral não está bem fundamentada na literatura. OBJETIVO: Investigar a ocorrência de variação da glicemia nos períodos pré, trans e pós-operatório de exodontia de dentes superiores, sob anestesia local com lidocaína 2% sem e com adrenalina 1:100.000, em portadores de diabetes mellitus tipo 2. Secundariamente, avaliar os efeitos hemodinâmicos e o grau de ansiedade. MÉTODOS: Estudo prospectivo e randomizado com pacientes portadores de diabetes acompanhados na Unidade Clinica de Coronariopatia Crônica do Instituto do Coração do Hospital das Clinicas da Faculdade de Medicina da Universidade de São Paulo. A monitorização contínua da glicemia durante 24 horas foi realizada através do MiniMed Continuous Glucose Monitoring System (CGMS, Medtronic). Os pacientes foram divididos em dois grupos: LSA - que recebeu 5,4 mL lidocaína 2% sem adrenalina e LCA - que recebeu 5,4 mL de lidocaína 2% com adrenalina 1:100.000. Os níveis de glicemia foram avaliados nas 24 horas (período basal) e nos tempos determinados: uma hora antes, durantes e até uma hora após a exodontia (período de procedimento). Os parâmetros hemodinâmicos foram avaliados por meio de um medidor de pressão arterial digital automático e o nível de ansiedade através de uma escala. RESULTADOS: Dos 400 pacientes avaliados, 70 foram incluídos no estudo, sendo 35 randomizados no grupo LSA e 35 no grupo LCA. A análise das médias da glicemia nos grupos LSA e LCA durante os períodos (basal e procedimento) não demonstrou diferença estatisticamente significativa (p=0,229 e p=0,811, respectivamente). Também não houve diferença significativa (p=0,748) na glicemia entre os grupos em cada tempo avaliado. Entretanto, nos dois grupos houve decréscimo significativo da glicemia (p < 0,001) ao longo dos tempos avaliados. Os grupos LSA e LCA não apresentaram diferenças significativas em relação à PAS (p=0,176), à PAD (p=0,913), à FC (p=0,570) e ao nível de ansiedade. CONCLUSÃO: A administração de 5,4mL de lidocaína 2% com adrenalina 1:100.000 não provocou alteração significativa da glicemia, parâmetros hemodinâmicos e nível de ansiedade em relação ao grupo sem vasoconstritor / INTRODUCTION: The safety of administration of local anesthetics with epinephrine for diabetic patients undergoing oral surgery is not well grounded in the literature. OBJECTIVE: To investigate the occurrence of variation of glucose in the pre, intra and postoperative extraction of upper teeth under local anesthesia with lidocaine 2% with and without 1:100.000 epinephrine in patients with type 2 diabetes mellitus. Secondly, to evaluate the hemodynamic effects and degree of anxiety. METHODS: A prospective randomized study of patients with diabetes attended in Coronary Chronic Clinics Unit, Heart Institute, Hospital das Clinicas in University of São Paulo Medical School. Continuous monitoring of blood glucose for 24 hours was performed using MiniMed Continuous Glucose Monitoring System (CGMS, Medtronic) and the patients were divided into two groups: LSA - which received 5.4 mL of 2% lidocaine without epinephrine and LCA - which received 5.4 mL of 2% lidocaine with 1:100,000 epinephrine. Blood glucose levels were assessed at 24 hours (baseline period) and at certain times: one hour before, during, and up to one hour after oral surgery (procedure period). We evaluated the hemodynamic parameters through a digital automatic pressure meter and anxiety level was measured by the scale. RESULTS: Of 400 patients evaluated, 70 were included in these study, 35 were randomized in the LSA group and 35 in the group LCA. The analysis of mean glicemia in groups LSA and LCA during the baseline period and procedure showed no statistically significant difference (p = 0.229 and p = 0.811, respectively). There was no difference in blood glucose (p = 0.748) between the groups at each time evaluated. However, in both groups there was a significant decrease in blood glucose (p < 0.001) over the time periods studied. The groups showed no significant differences regarding SBP (p = 0.176), DBP (p = 0.913), HR (p = 0.570) and anxiety level. CONCLUSION: The administration of 5.4 mL of 2% lidocaine with epinephrine 1:100.000 caused no significant change in blood glucose, hemodynamic parameters and level of anxiety compared to the group without vasoconstrictor

Page generated in 0.0658 seconds