• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 160
  • 56
  • 13
  • 10
  • 6
  • 4
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 271
  • 72
  • 44
  • 42
  • 41
  • 38
  • 33
  • 32
  • 24
  • 24
  • 24
  • 21
  • 21
  • 21
  • 20
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
161

Eficácia de diferentes técnicas de retratamento endodôntico de canais radiculares curvos

Costa, Débora Delai January 2018 (has links)
Introdução: Os objetivos deste estudo foram comparar a extrusão apical de debris durante a desobturação com WaveOne Gold, ProTaper retratamento, D-RaCe ou limas manuais; descrever as falhas e/ou fraturas ocorridas nos instrumentos de NiTi; e comparar o WaveOne Gold com os sistemas ProTaper e RaCe em relação à quantidade de material obturador remanescente, transporte apical (TA) e tempo de trabalho após a desobturação e após o repreparo de canais radiculares curvos. Materiais e Métodos: Quarenta canais mésiovestibulares de molares superiores foram preparados, obturados e divididos em 4 grupos (n=10): WOG) WaveOne Gold Primary e Medium; PTG) ProTaper Retreatmento e ProTaper Next; RCG) D-RaCe e RaCe; e LM) Limas manuais. A extrusão de debris foi determinada subtraindo-se o peso final do peso inicial dos Eppendorfs. Os instrumentos de NiTi (n=18) foram analisados em MEV antes e após a desobturação. A quantidade de material obturador remanescente e o TA foram avaliados em micro-TC. O tempo de trabalho foi anotado e comparado. Os dados foram estatisticamente analisados (α=.05). Resultados: WOG extruiu menos debris do que LM e RCG (P<.05), e foi similar ao PTG (P>.05). Não houve diferença entre LM, PTG e RCG (P>.05). A análise em MEV mostrou, dos 18 instrumentos avaliados, 3 fraturas e 10 deformações. Nas duas etapas avaliadas, WOG apresentou similar (P>.05) e menor (P<.05) quantidade de material obturador remanescente do que PTG e RCG, respectivamente. A quantidade de material no WOG e RCG foi menor após o repreparo (P<.05). Na desobturação, WOG teve maior TA em 4mm do que em 2mm (P<.05). Em 2mm, o TA do WOG foi menor do que RCG (P<.05), e em 4mm foi igual ao PTG e RCG (P>.05). Na desobturação, o tempo de trabalho no grupo LM foi maior que nos demais (P<.05). No repreparo, WOG foi mais rápido do que PTG e RCG (P<.05). Conclusões: Todos os instrumentos causaram extrusão de debris, sendo que o WOG apresentou os menores valores. Nenhum sistema removeu completamente o material obturador de raízes mésiovestibulares de molares superiores. Considerando os baixos valores de TA obtidos, os instrumentos avaliados foram considerados seguros para desobturação e repreparo de canais curvos. A desobturação com LM foi mais lenta do que com os instrumentos de NiTi. O sistema reciprocante foi mais rápido do que os rotatórios no reprepro. / Introduction: The aims of this study were to assess the amount of apically extruded debris during filling removal with WaveOne Gold, ProTaper Retreatment, D-RaCe or hand files; to describe failures of NiTi instruments; and to compare WaveOne Gold with ProTaper and RaCe systems regarding remaining filling material, apical transportation (AT) and working time after filling removal and after shaping of curved root canals. Methods: Forty mesiobuccal canals of maxillary molars were prepared, filled, and assigned into 4 groups (n=10): WOG) WaveOne Gold Primary and Medium; PTG) ProTaper Retreatment and ProTaper Next; RCG) D-RaCe and RaCe; HF) Hand files. The amount of extruded debris was determined by subtracting the final from the initial Eppendorfs weight. The NiTi instruments (n=18) used for filling removal were analyzed pre and post-operatively by SEM. Micro-CT analysis assessed the residual filling material and AT. Working time was recorded and compared. Data were statistically analyzed (α=.05). Results: WOG produced less debris compared with HF and RCG (P<.05), and similar to PTG (P>.05). HF, PTG and RCG showed no difference (P>.05). SEM analyses after filling removal showed, from the 18 instruments evaluated, 3 fractures and 10 deformations. In both evaluated steps, WOG had similar (P>.05) and less (P<.05) amount of filling material as PTG and RCG, respectively. The remaining material in WOG and RCG was lower after shaping (P<.05). In filling removal, WOG had higher AT at 4mm than at 2mm (P<.05). At 2mm, AT of WOG was lower than RCG (P<.05), and at 4mm, was equal to PTG and RCG (P>.05). In filling removal, working time in HF group was significantly higher than others (P<.05). In shaping step WOG was faster than PTG and RCG (P<.05). Conclusions: All instruments tested caused debris extrusion, with WOG presenting the lowest values. Neither system could completely remove the filling material of mesiobuccal canals of maxillary molars. Considering the low AT values obtained, the instruments evaluated were safe for filling removal and shaping of curved canals. Filling removal with HF was slower than with the NiTi files. The reciprocating system was faster than the rotary in shaping the root canals.
162

Os efeitos biológicos da laserterapia de baixa intensidade em células-tronco isoladas da papila apical humana

Medeiros, Hianne Cristinne de Morais 25 July 2016 (has links)
Submitted by Jean Medeiros (jeanletras@uepb.edu.br) on 2018-05-17T12:44:27Z No. of bitstreams: 1 PDF - Hianne Cristinne de Morais Medeiros.pdf: 40241302 bytes, checksum: b59180daf15773487da025912d0ff8bb (MD5) / Approved for entry into archive by Secta BC (secta.csu.bc@uepb.edu.br) on 2018-05-23T16:59:05Z (GMT) No. of bitstreams: 1 PDF - Hianne Cristinne de Morais Medeiros.pdf: 40241302 bytes, checksum: b59180daf15773487da025912d0ff8bb (MD5) / Made available in DSpace on 2018-05-23T16:59:05Z (GMT). No. of bitstreams: 1 PDF - Hianne Cristinne de Morais Medeiros.pdf: 40241302 bytes, checksum: b59180daf15773487da025912d0ff8bb (MD5) Previous issue date: 2016-07-25 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The aim of this study was to analyze the effects of low-intensity laser therapy (LILT) in stem cells from apical papilla (SCAPs) proliferation. Stem cells isolated from apical papilla cells were donated by the cell bank from Pharmaceutical Nanotechnology Laboratory and Drug Delivery Systems, Federal University of Goiás (UFG). Cells were cultured in 75cm^2 bottles and kept in a humidified stove at 37 °C in a saturated atmosphere at 5% CO2. Standard culture medium used was composed of Dulbecco's modified Eagle's medium nutrient mixture F-12 (DMEM / F12), 10%, fetal bovine serum ,100 ug / ml streptomycin and 100 U / ml penicillin. For irradiation, the semiconductor laser diode(InGaAlP) was used at a wavelength of 660 nm, 100mW power, 6J energy, 60 seconds for irradiation time and 200 J / cm². Dose. Initially, the intensity of mitochondrial metabolism was evaluated by immunofluorescence. For this, we used Mitotraker Red in a concentration of 100mM. Intensities of mitochondrial activity was compared in non-irradiated cells, and after two irradiation times: immediately to the application of LILT and 24h after application. In order to assess the immunoreactivity of proteins involved in cell proliferation, it performed immunocytochemistry using Ki-67, p53, Bcl-2, Cyclin B1, TGF-β2 and TGF-β3 .The incubation time for the primary antibody exposure was standardized at 2hours. For each antibody, two different groups were analyzed: non-irradiated (CNT) and irradiated (G6J). The progression of the cell cycle analysis was performed, by flow cytometry. The results obtained in the groups irradiated and non-irradiated were compared. The normality of the data distribution was tested using the Kolmogov- Sminorv test. To check the diferences in the immunoreactivity between the groups, were used the Mann-Whitney test and to check whether there was a statistical difference between the groups regarding the progression of the cell cycle, we used the nonparametric T test. In both cases, it was adopted significance of 5%. Increased mitochondrial activity was evident immediately from the time of irradiation, and this metabolic activity increase even more after 24 hours of exposure to LILT The irradiated group showed greater median percentage of immunopositive Ki-67 and Cyclin B1. However, in both cases, there was no statistical significance when compared to control groups. There was no difference in TGF-β expression. Likewise, it was also no difference obtained as the p53 and Bcl-2, which indicates that the LILT does not deregulating the maintenance of cell cycle progression and control of apoptosis. There was no disagreement on the chronology of cell cycle progression between the groups irradiated and non-irradiated. Thus, it is possible to conclude that the LILT increases mitochondrial metabolism of isolated stem cells of the apical papila and it can influence the imunoexpression of proliferation marker. Furthermore, the irradiation of SCAPs does not result in any damage to regulation of cell proliferation and apoptosis functions. / O objetivo deste trabalho consistiu na análise dos efeitos da laserterapia de baixa intensidade (LBI) na atividade biológica de células-tronco isoladas da papila apical (SCAPs). Foram utilizadas células-tronco isoladas da papila apical doadas pelo banco de células do Laboratório de Nanotecnologia Farmacêutica e Sistemas de Liberação de Fármacos da Universidade Federal de Goiás (UFG). As células foram cultivadas em garrafas de 75cm^2 e mantidas em estufa umidificada a 37°C em atmosfera saturada em 5% de CO2. Foi utilizado meio de cultura padrão composto por Dulbecco's modified Eagle's medium nutrient mixture F-12 (DMEM/F12), soro fetal bovino a 10%, 100 µg/mL de estreptomicina e 100 U/mL de penicilina. Para irradiação, foi utilizado o laser semicondutor diodo (InGaAlP), no comprimento de onda de 660 nm, potência de 100mW, energia de 6J, tempo de irradiação de 60 segundos. Inicialmente, foi avaliada a intensidade do metabolismo mitocondrial por meio de imunofluorescência com o uso do Mitotraker Red. Foram comparadas as intensidades de atividade mitocondrial em células não irradiadas, e após dois tempos de irradiação: imediato à aplicação do LBI e 24h após a aplicação. Com o intuito de avaliar a imunoexpressão de proteínas reguladoras, foi realizada imunocitoquímica, empregado os marcadores Ki-67, Ciclina B1, TGF-β2 e TGF-β, p53, Bcl-2. Para cada anticorpo, foram analisados dois grupos distintos de células: um não irradiado (CNT) e outro irradiado (G6J). A análise da progressão do ciclo celular foi realizada no tempo de 8h por meio da marcação com Iodeto de Propídeo, as células foram quantificadas de acordo com a fase do ciclo em que se encontravam, por meio de citometria de fluxo. Foram comparados os resultados obtidos nos grupos irradiados e não irradiados. A normalidade de distribuição dos dados foi testada utilizando o teste de Kolmogov-Sminorv. . Para verificar as diferenças nos percentuais de imunoreatividade, foi utilizado o teste de Mann- Whitney e para verificar se houve diferença estatística entre os grupos quanto a progressão do ciclo celular, foi utilizado o teste T não paramétrico. Em ambos os casos, foi adotada significância de 5%. O aumento da atividade mitocondrial foi evidente desde o momento imediato da irradiação, sendo este aumento metabólico ainda maior após 24h de exposição ao LBI. As células irradiadas com LBI vermelho apresentaram maiores medianas de percentuais de imunopositividade ao Ki-67 e a Ciclina B1. Não houve diferença quanto à expressão de TGF-β. Da mesma forma, também não foi obtida diferença quanto à imunoexpressão do p53 e Bcl-2, o que indica que o LBI não desregula genes importantes na manutenção da progressão do ciclo celular e controle da apoptose. Também não houve divergências quanto à cronologia da progressão do ciclo celular entre os grupos irradiados e não irradiados. Desta forma, é possível concluir que a absorção da luz pelas SCAPs resulta em aumento imediato do metabolismo mitocondrial que pode influenciar a maior expressão do marcador de proliferação nestas células. Também foi demonstrado que a irradiação destas células não resulta em nenhum dano à regulação das funções vitais de proliferação celular e apoptose.
163

Influência do diâmetro do forame apical e do calibre do instrumento endodôntico nas leituras odontométricas proporcionadas por dois aparelhos localizadores apicais / Influence of foramen diameter and endodontic instrument size on odontometry reading by two electronic apex locators

Járcio Victório Baldi 17 June 2005 (has links)
Este estudo objetivou avaliar a influência do diâmetro do forame e do instrumento endodôntico na leitura odontométrica de dois aparelhos localizadores apicais eletrônicos. Foram utilizados 40 dentes incisivos inferiores, divididos em 4 grupos, de acordo com o diâmetro do forame apical (100, 200, 300 e 400 µm). Após a abertura coronária desses dentes e o acesso aos canais radiculares, realizou-se a medição do comprimento dos mesmos com auxílio de um microscópio clínico com ampliação de 7,8X, da incisal até que a ponta da lima surgisse no forame apical. Os dentes foram colocados em potes individuais contendo solução de ágar a 1% em solução salina de fosfato tamponado, mantendo-se cerca de 2/3 de suas raízes imersas na solução para que pudesse ser feita a leitura com o Root ZX® (J.Morita, Japão) e o NovApex® (Fórum, Israel). Os mesmos foram medidos com limas nº10 até que a distância de 0,5 mm do ápice fosse acusada no display dos aparelhos. Uma outra medida foi realizada nos dentes utilizando-se lima nº10 e limas com diâmetros correspondentes ao diâmetro dos forames (200µm, 300µm e 400µm). Para a análise estatística foi empregado o teste de Análise de Variância a dois critérios para o confronto global entre os aparelhos e o emprego da lima nº10 em todos os dentes e teste de Tukey para as comparações individuais. Os resultados demonstraram diferença estatística na precisão dos dois aparelhos com um resultado mais preciso para o Root ZX® (p<0,05). Dentes com forame, de menor diâmetro, apresentaram uma medida mais precisa com o localizador apical e dentes com forame de maior diâmetro apresentaram uma maior discrepância na medida. O emprego de limas tipo K nº10 nos dentes com forames de diâmetros maiores apresentaram maior precisão na medição quando comparadas às limas coincidentes aos diâmetros dos forames para o aparelho Root ZX®. Para o NovApex® esta correlação só passou a ocorrer a partir da lima nº40. / This study evaluated the influence of foramen diameter and endodontic instrument size on the odontometry reading of two electronic apical measuring devices. Forty mandibular incisors were used, which were divided into four groups according to the apical foramen diameter (100, 200, 300 and 400µm). After coronal opening of these teeth and access to the root canals, the root canal length was measured with aid of a clinical microscope with 7.8x magnification, from the incisal edge until the file tip reached the apical foramen. Ten teeth with 100-µm diameter were placed in individual jars containing 1% agar solution in phosphate-buffered saline, maintaining around 2/3 of their roots immersed in the solution to allow measurement with Root ZX (J. Morita, Japan) and NovApex (Forum, Israel). Teeth were measured with files n. 10 until the distance of 0.5mm from the apex was indicated by the device. Another measurement was performed on the other thirty teeth with files n. 10 and files with diameters corresponding to the foramen diameters (200µm, 300µm and 400µm). Statistical analysis was performed by two-way analysis of variance for overall comparison between the devices and employment of file n. 10 in all teeth, and Tukey test for individual comparisons. The results demonstrated statistical difference in the precision of both devices, with a more accurate result for Root ZX (p<0.05). Teeth with narrower foramina presented a more accurate measurement with the apical measuring device, and teeth with wider foramina presented larger discrepancy in the measurement. Utilization of K file n. 10 in teeth with wider foramina showed more accurate measurements compared to files with size corresponding to the foramen diameters with the Root ZX® device. With the NovApex® device, this correlation was only observed with file n. 40.
164

"Avaliação da vedação apical proporcionada por três materiais retroobturadores" / Evaluation of sealing ability of three root-end filling materials

Claudia Panzani 14 December 2005 (has links)
A cirurgia parendodôntica é um recurso utilizado para solucionar casos em que a terapia endodôntica não obteve sucesso, ou ainda na impossibilidade da sua realização. A escolha de um material retroobturador adequado pode contribuir positivamente para o reparo tecidual. Este estudo teve como objetivo avaliar a capacidade seladora de três materiais usados para retroobturação, em dois tempos diferentes, tendo como marcador o corante Rodamina B a 0,2%. Sessenta e seis dentes tiveram as suas coroas seccionadas, os canais preparados com limas manuais e obturados com cimento e guta-percha. Seccionaram-se dois milímetros da porção apical e cavidades retrógradas foram preparadas com pontas de ultra-som lisas; dividindo-se então, em 3 grupos experimentais que receberam os seguintes materiais: MTA Ângelus ® , Real Seal ® e um material experimental desenvolvido pelo IPEN-USP (Instituto de Pesquisas Energéticas e Nucleares da Universidade de São Paulo). Dez elementos de cada grupo foram imersos em soro fisiológico durante 72h a 37°C, antes de serem impermeabilizados e colocados no corante por 24h (grupos I A, II A e III A). Os demais permaneceram 60 dias em soro fisiológico para depois serem impermeabilizados e colocados no marcador (grupos I B, II B e III B). O controle positivo consistiu de 3 espécimes, que não tiveram as cavidades retroobturadas. Outros três espécimes serviram como controle negativo, cada um foi retroobturado com um dos materiais em estudo e foram totalmente impermeabilizados antes de serem imersos no corante. Após o tempo de imersão no corante, todos os espécimes foram lavados, e em seguida, clivados ongitudinalmente no sentido mésio-distal. As superfícies foram avaliadas em lupa estereoscópica com aumento de 20X e fotografadas. A infiltração linear foi medida com auxílio de uma lente reticulada e régua milimetrada. Os resultados foram submetidos aos testes estatísticos de Kruskal-Wallis e verificou-se que não houve diferença entre os grupos do MTA Ângelus ® e do Real Seal ® , sendo que a maior infiltração do corante ocorreu na interface dentina-material experimental, com diferença estatisticamente significante ao nível de 1% (a=0,01). Fazendo a análise estatística de Mann-Whitney entre os grupos com o mesmo material, verificou-se que o tempo de permanência em umidade até 60 dias não influenciou na vedação dos materiais retroobturadores. / Apical surgery is a resource that is used to solve cases in which endodontic therapy was either unsuccessful or could not be done. Choice of root-end filling material contributes for successful. The purpose of this study was to evaluate the sealing ability of three materials used for root-end filling, using 0.2% Rhodamine B. Sixty-six teeth had their crowns removed, and their canals were cleaned and shaped with manual files, and filled with cement and gutta-percha. Two millimeters of the apical portion were sectioned and root-end cavities were prepared in all specimens with smooth ultrasonic tips. Three groups were formed to receive the following materials: MTA Ângelus ® , Real Seal ® , and an experimental material developed by the IPEN-USP (Institute of Energetic and Nuclear Research from São Paulo University). Ten specimens from each group were immersed in a physiological saline solution for 72h at 37°C, before being waterproofed and put in the colorant for 24 h (groups I A, II A, and III A). The others remained in physiological saline solution for 60 days and were then waterproofed and put in the marker (groups I B, II B, and III B). The positive control consisted of three specimens that did not have their cavities root-end filled. Another three specimens served as a negative control, each being root-end filled with one of the materials being studied, and they were totally waterproofed before being immersed in Rhodamine B. After the time of immersion in the colorant, all of the Speci mens were washed and then cleaved longitudinally in the mesio-distal direction. The surfaces were evaluated under a stereoscopic magnifying glass at 20X magnification and photographed. The linear infiltration was measured with a micro metered lens and millimeter rule . The results were submitted to the Kruskal-Wallis statistical tests and it was noticed that there was no difference between the MTA Ângelus ® and Real Seal ® groups. The experimental material presents the most colorant microleakage, with a statistically significant difference (a=0.01). The Mann-Whitney statistical analysis performed in the groups with the same material showed that the period of time the specimen remained exposed to moisture - up to 60 days - did not impact the materials’ sealing capacity.
165

Envolvimento de sinais coestimulatórios na periodontite apical crônica em humanos

Ronan Jacques Rezende Delgado 01 September 2011 (has links)
As lesões periapicais são induzidas por uma infecção crônica da polpa dental. Antígenos microbianos estimulam a resposta imune específica e inespecífica nos tecidos apicais. Como consequência desse processo, diante da incapacidade das defesas do hospedeiro para erradicar a infecção, uma lesão periapical é formada, com o objetivo de restringir a invasão microbiana. O desenvolvimento da periodontite apical crônica depende de uma fina regulação da ativação dos linfócitos. A ativação das células T requer dois sinais, um mediado pelo complexo TCR, após o reconhecimento do antígeno, e o outro mediado pela interação dos receptores coestimulatórios. CD28 é um receptor coestimulatório, enquanto CTLA-4 e PD-1 induzem um sinal inibitório para a ativação de células T. Para compreender o envolvimento de células T na periodontite apical crônica, avaliamos a presença destas células na lesão periapical e os fatores coestimulatórios, citocinas e espécies reativas do oxigênio que estas células estariam produzindo. As amostras analisadas foram de tecido gengival para o grupo controle (n = 20) e lesões periapicais para o grupo com periodontite apical crônica (n = 20). Quanto ao perfil celular das lesões periapicais, os resultados mostraram que linfócitos T (59,3 ± 3,7%) foram as células predominantes, sendo a subpopulação CD4+ (72,7 ± 3,4%) a mais encontrada. A seguir, verificou-se a expressão de moléculas de superfície em células T. Observou-se que a expressão de CD28 (0,5 ± 0,5%) foi significativamente mais baixa em amostras de lesões periapicais que no grupo controle principalmente para linfócito T CD8+. Já CTLA-4 foi identificado em altos níveis para pacientes com periodontite apical tanto para CD3+CD4+ (86,1 ± 2,6%) quanto para CD3+CD8+ (59,8 ± 8,6%). PD-1 (73,5 ± 5,6%) e PD-L1 (59,8 ± 8,6%) apresentaram alta positividade para CD3+CD4+. Esses resultados indicaram um possível envolvimento da via de sinalização de PD-1 e PD-L1 na modulação da resposta de células T de pacientes com periodontite apical crônica. A dosagem de citocinas revelou alta positividade para todas as citocinas investigadas (TGF-; TNF-; IFN- e IL-10). Óxido Nítrico e mieloperoxidase produzidas por neutrófilos e responsáveis pela degradação tecidual também foram detectadas em altas doses nas amostras de pacientes com periodontite apical. O conhecimento sobre o papel das moléculas coestimulatórias na imunopatogênese da periodontite apical crônica servirá de base para o direcionamento de novas estratégias de prevenção, assim como o desenvolvimento de novos procedimentos terapêuticos. / Periapical lesions are induced by the chronic infection of dental pulp. Microbial antigens stimulate both non-specific and specific immune response in periapical tissue. As a consequence of these processes and the inability of host defense mechanisms to eradicate infection, chronic periapical lesion are formed, with the aim of restricting microbial invasion. Negative co-stimulatory signals mediated via cell surface molecules such as cytotoxic T-lymphocyte-associated antigen 4 (CTLA-4) and programmed death-1 (PD-1) play a critical role in down- modulation immune responses and maintaining peripheral tolerance. Both CTLA-4 and PD-1 are induced on actived T cell, and these are involved in the immunophatogenesis of periapical lesions. Inhibitory signals mediated via molecules such as programmed-death-1 (PD-1) play a critical role in down-modulating immune responses and maintaining peripheral tolerance. We investigated the involvement of cytokines and PD-1 engagement in mediating the T cell activation in chronic periapical diseases. Gingival samples from healthy individuals (n= 20) and patients with chronic periapical periodontitis (n= 20) were collected and used for the subsequent assays. The leukocytes in the lesion site were evaluated using flow cytometry. The production of cytokines interferon-gamma (IFN-), interleukin (IL)-10, tumor necrosis factor-alpha (TNF-) and transforming growth factor-beta (TGF-) was evaluated by ELISA. We observed a significant increase in the total number of leukocytes from periapical lesions as compared with healthy group. Our results for the composition of infiltrating cell in periapical lesion showed that the predominant cells were lymphocytes T (59,3 ± 3,7%) and contained a higher proportion of CD4+ cells (72,7 ± 3,4%). T cells from patients with periapical lesions expressed significantly higher levels of PD-1 (73,5 ± 5,6%) and PD-L1 (59,8 ± 8,6%). The levels of CTLA-4 were higher in CD3+CD4+ (86,1± 2,6%) and CD3+ CD8+ (59,8 ± 8,6%) cells, but in contrast the expression of CD28 was lower than control group. In addition, CD4+ and CD8+ T cells expressing PD-1 accumulate in lesions with chronic periapical periodontitis. Moreover, PD-L1 expression was intense in macrophage from patients. Our data clearly showed that lesions samples contained elevated amounts of TGF-, IL-10, TNF- and IFN- when compared with healthy gingival tissue from control individuals. These data show that PD-1 and CTLA-4 engagement could be involved in the modulation of T cells activation in patients with chronic periapical periodontitis.
166

Análise, através de tomografia computadorizada, do preparo promovido pelo alargamento cervical em molares inferiores e sua influência na determinação do diâmetro anatômico apical por meio de MEV / Analysis of the cervical preflaring of lower molars by means of cone beam computed tomography, and its influence on the determination of apical gauging by scanning electron microscopy

Homero Casonato Júnior 19 April 2011 (has links)
O objetivo no presente estudo foi avaliar, por meio de tomografia computadorizada cone beam, o transporte do canal, o aumento da área do canal e o desgaste da dentina intrarradicular na região voltada para a furca de molares inferiores com diferentes instrumentos e verificar a influência do desgaste na determinação do instrumento apical inicial (IAI) por meio de MEV. Os dentes foram dispostos (n=10) em três bases de resina (corpos de prova) de acordo com o tipo de preparo cervical e submetidos ao escaneamento em tomógrafo computadorizado de feixe cônico. Em seguida foi realizado o preparo cervical nos canais mesiais G1: Gattes-Glidden 2 e 3 nos canais mesiais e 3 e 4 no distal; G2 LA Axxess 20.06 e 35.06 nos canais mesiais e 35.06 e 45.06 no canal distal. Concluído o preparo do terço cervical os corpos de prova foram submetidos a novo exame tomográfico. O IAI foi determinado inserindo-se passivamente limas tipo K de aço inox, seqüencialmente a partir da lima #10 até obter a sensação de travamento do instrumento no comprimento de trabalho, em seguida este instrumento foi fixado utilizando-se adesivo à base de cianoacrilato para posterior corte apical e observação em MEV. O índice de centralização não mostrou diferença estatística entre os grupos estudados. O aumento percentualda área do canal pós preparo apresentou diferença estatisticamente significante apenas no canal mesio-lingual (p=0,023), o desgaste da dentina intraradicular na região voltada para a furca foi estatisticamente diferente somente na raiz distal. Os resultados mostraram que o percentual médio de ocupação da área do canal pelo IAI não apresentou diferença estatística entre os grupos estudados. Concluiu-se que o desgaste da região de cervical com Gates-Glidden e LA Axxxes não influenciou na determinação precisa do diâmetro anatômico apical nos canais de molares inferiores. / The aim of this study was to evaluate, by means of cone beam computed tomography, the transportation, the increased of the area, and the dentine thickness of the cervical third of the root canal of thirty lower first molars prepared with different instruments and the influence of this preparation to determining the initial apical file to bind (IAI), through scanning electron microscopy. The teeth (n = 10) were fixed on three resin plates (samples) according to the instrumentsused in the cervical preflaring and scanned with a cone beam computed tomography device. Then, preparation was performed in the cervical third of the canals: G1 Gattes-Glidden burs #2 and #3 in the mesial canals and #3 and #4 in the distal canal; G2 - LA Axxess #20.06 and #35.06 in the mesial canals and #35.06 and #45.06 in the distal canal. After preparation, the specimens were submitted to a new CT scan. Each canal was sized using manual K-files, starting with size 08 files, until the working length (WL) was reached. File sizes were increased until a binding sensation was felt at the WL, and the instrument sizewas recorded for each canal. The files were fixed with methylcyanacrylate at the WL. Teeth were then sectioned transversally 1 mm from the apex, with the binding file in the position. The apical region was then observed under a scanning electron microscope. The centering ratio showed no statistical difference between groups; the percentage of area increase after preparation showed statistical significance only in the mesio-lingual canal (P = 0.023); the thickness of the dentine in the region facing the furcation showed statistical difference only in the distal root. SEM analysis showed that the mean percentage area of the IAI in relation to the root canal area at the WL showed no statisticalsignificant difference between groups. It was concluded that cervical preflaring with Gates-Glidden or LA Axxess did not influence the determination of the apical gauging in lower molars.
167

Comparação do comprimento de trabalho do canal radicular usando tomografia computadorizada de feixe cônico, radiografia periapical e localizador apical eletrônico / In vivo comparison of root canal working length using cone beam computed tomography, periapical radiograph, and electronic apex locator

MORAIS, André Luiz Gomide de 13 February 2012 (has links)
Made available in DSpace on 2014-07-29T15:21:58Z (GMT). No. of bitstreams: 1 Dissertacao Andre Luiz Gomide de Morais.pdf: 1627953 bytes, checksum: 05ab427707618c3afdeb890e320268e6 (MD5) Previous issue date: 2012-02-13 / Introduction Strategies to obtain the working length to prepare and fill the root canals has been relevant theme of discussion in endodontics. The purpose of this study was to compare in vivo the canal root working length measures determined by cone beam computed tomography (CBCT) images with the ones obtained by using periapical radiograph and electronic apex locator. Methods The root canal working lengths of 30 single-rooted teeth from 19 patients whose diagnosis was apical periodontitis were evaluated. Initial periapical radiographs for diagnosis and treatment planning, employing the parallelism technique, were taken. CBCT images were acquired with i-CAT system (aiming of diagnosing the cases of apical periodontitis that showed to be complex and doubtful) and measured with specific function of i-CAT software. The coronal opening was made, the root canals were irrigated with sodium hypochlorite solution 2.5%, being performed the exploration and initial emptying of root canal. After, the preparation of the inlet orifice and of the cervical root third was carried out . The minor foramen was located using Root ZX® locator by advancing a stainless steel K-file that best suited the root canal, according to the manufacturer´s instructions. The radiographic measurement was made by advancing a stainless steel K-file in the root canal, until its tip was 1.0 mm from the root apex (determined from the measures obtained by the electronic ape locator). These 3 working length were tabulated and compared. Kruskal-Wallis test was used to analyze the differences between working lengths methods. The significance was set at &#945;=5%. Results The mean values and standard deviations for working length determination by electronic apex locator, periapical radiograph and CBCT images were 21.5 ± 3.1, 21.32 ± 3, 21.4 ± 2.7, respectively. Significant differences were not verified statistically (P>0.05). Conclusions CBCT images working length determination showed to be as similar as the determinations obtained by using periapical radiograph and electronic apex locator. / Introdução: Estratégias para obtenção do comprimento de trabalho para preparar e obturar canais radiculares têm sido tema relevante de discussão em Endodontia. O objetivo deste estudo foi comparar in vivo as medidas de comprimento de trabalho do canal radicular determinadas por meio da tomografia computadorizada de feixe cônico (TCFC) com as obtidas por meio de radiografia periapical e localizador apical eletrônico. Metodologia: Foram avaliados os comprimentos de trabalho dos canais radiculares em 30 dentes de 19 pacientes com diagnóstico de periodontite apical. Radiografias periapicais iniciais de diagnóstico e plano de tratamento, empregando a técnica do paralelismo, foram realizadas. As imagens de TCFC foram obtidas usando o sistema i-CAT (com o intuito de diagnosticar os casos de periodontite apical que se mostraram complexos ou duvidosos) e foram medidas a partir de função específica do programa desse sistema. Foi realizada a abertura coronária, os canais radiculares foram irrigados solução de hipoclorito de sódio a 2,5%, sendo realizada a exploração e o esvaziamento inicial do canal radicular. Depois foi realizado o preparo do orifício de entrada e do terço cervical da raiz. O forame apical foi localizado usando o localizador Root ZX® por meio do avanço de uma lima tipo K-file que melhor se adaptasse ao canal radicular de aço inoxidável no canal radicular, de acordo com instruções do fabricante. A medida radiográfica foi feita por meio da colocação de uma lima tipo K-file de aço inoxidável no canal radicular, até que sua ponta estivesse a 1,0mm do ápice radicular (determinado pelas medidas obtidas com o localizador apical eletrônico). Essas três medidas de comprimento de trabalho foram tabuladas e comparadas. O teste de Kruskal-Wallis foi empregado para analisar as diferenças entre os métodos de obtenção dos comprimentos de trabalho. O nível de significância foi estabelecido em &#945;=5%. Resultados: O valor médio e os desvios-padrões para a determinação do comprimento de trabalho por meio de imagens de TCFC, localizador apical eletrônico e radiografia periapical foram de e 21,4 ± 2,7, 21,5 ± 3,1, 21,32 ± 3, respectivamente. Diferenças significantes entre as medidas obtidas pelos três métodos não foram verificadas (p>0.05). Conclusões: A determinação do comprimento de trabalho em imagens de TCFC mostrou ser tão similar quanto às determinações obtidas por meio do método radiográfico e do localizador apical eletrônico.
168

Características agronômicas e índices de trocas gasosas de cultivares de tomateiro com diferentes números de hastes por planta

Dalastra, Graciela Maiara 30 May 2017 (has links)
Submitted by Helena Bejio (helena.bejio@unioeste.br) on 2017-11-22T18:17:08Z No. of bitstreams: 2 Graciela M Dalastra 2017.pdf: 743009 bytes, checksum: 8b9774d8d27ee8b7752b08234a58e7ad (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2017-11-22T18:17:09Z (GMT). No. of bitstreams: 2 Graciela M Dalastra 2017.pdf: 743009 bytes, checksum: 8b9774d8d27ee8b7752b08234a58e7ad (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2017-05-30 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / This work aimed to study the influence of the number of stems per plant in agronomic characteristics and on the gas exchange indexes of two tomato cultivars. The experimental design was of randomized blocks in factorial scheme 2 x 5, with four replicates. The first factor is constituted by two tomatoes cultivars (Giuliana and Tyna) and the second by the number of rods in the plants, being: (1) only the main stem; (2) main stem + secondary stem issued immediately below the first bunch; (3) the first two secondary rods that arise in the plant with the emerge of the main stem; (4) the first four secondary rods that arise in the plant with the emerge of the main stem; (5) main stem and three secondary rods issued below the first bunch. The mean mass, longitudinal and transverse diameter of the fruits evaluated and productivity was estimated. The pH, soluble solids content, titratable acidity and soluble solids / titratable acidity ratio, ascorbic acid content and lycopene were also evaluated. The evaluated characteristics were: liquid assimilations rates of CO2 (A), leaf transpiration (E), stomatal conductance (gs) and inner concentration of CO2 (Ci). From these measures was possible to calculate the instantaneous efficiency of the use of water (EUA) and carboxylation (ACi). The production of Giuliana cultivar war 32% higher than Tyna cultivar. Regarding the types of driving rods there was no difference between the for the characteristics related to the size of the fruit, for the soluble solids the driving type 2 and 3 presented highest values. The lycopene values are considered suitable. In relation of the types of conduction the bigger rates of A was observed to the conduction type 3, although did not resulted in significant differences in the productivity. / Este trabalho teve como objetivo estudar a influência do número de hastes por planta nas características agronômicas e nos índices de trocas gasosas de duas cultivares de tomateiro. O delineamento experimental utilizado foi de blocos casualizados, em esquema fatorial de 2 x 5, com quatro repetições. O primeiro fator constitui-se por duas cultivares de tomate Italiano (Giuliana e Tyna) e o segundo, pelo número de hastes nas plantas, sendo: (1) apenas a haste principal; (2) haste principal + haste secundária emitida imediatamente abaixo do primeiro cacho; (3) as duas primeiras hastes secundárias que surgirem na planta com o desponte da haste principal; (4) as quatro primeiras hastes secundárias que surgirem na planta com o desponte da haste principal; (5) haste principal e mais três hastes secundárias emitidas abaixo do primeiro cacho. Foi avaliado massa média, diâmetro longitudinal e transversal dos frutos e estimada a produtividade. Também foi avaliado o pH, teor de sólidos solúveis, acidez titulável, relação sólidos solúveis/acidez titulável (“ratio”), teor de ácido ascórbico e licopeno. Para os índices de trocas gasosas foi mensurada taxa de assimilação líquida de CO2 (A), transpiração foliar (E), condutância estomática (gs), concentração interna de CO2 (Ci). Também foi calculada a eficiência no uso da água (EUA) e a eficiência instantânea de carboxilação (ACi). A produção da cultivar Giuliana foi 32% superior que da cultivar Tyna. Em relação aos tipos de condução das hastes não houve diferença entre os tratamentos para as características relacionadas ao tamanho dos frutos. Para o teor de sólidos solúveis o tipo de condução 2 e 3 apresentaram os maiores valores. Os valores de licopeno são considerados adequados. Com relação aos tipos de condução os maiores valores da A foi observado para o tipo de condução 3, porém não resultou em diferenças significativas na produtividade.
169

Terapia fotodinâmica antimicrobiana (aPDT) no tratamento de lesões periapicais induzidas experimentalmente, em dentes de cães / Antimicrobial photodynamic therapy in the treatment of apical periodontitis induced experimentally in dogs\' teeth

Lidia Regina da Costa Hidalgo 16 September 2016 (has links)
Avaliar in vivo o efeito da Terapia Fotodinâmica Antimicrobiana (aPDT), após tratamento endodôntico em sessão única, em dentes de cães com lesão periapical, em comparação ao tratamento em duas sessões com o uso de curativo de demora à base de hidróxido de cálcio. Material e Métodos: Após a indução experimental da lesão periapical e instrumentação dos canais radiculares, 48 dentes foram distribuídos nos seguintes grupos: I e III Uso de curativo de demora com pasta à base de hidróxido de cálcio (Calen®); e II e IV -Tratamento em uma única sessão com utilização da aPDT. Os canais radiculares foram obturados e decorridos os períodos experimentais de 120 dias (Grupos I e II) e 180 dias (Grupos III e IV), os animais foram submetidos à eutanásia. Após processamento histotécnico, análise microscópica descritiva/semi-quantitativa, avaliação morfométrica do tamanho da lesão periapical em microscopia de fluorescência e análise radiográfica foram realizadas. Foram utilizados os testes de Kruskal Wallis e exato de Fisher (=0,05). Resultados: Na análise microscópica descritiva, os grupos I e III apresentaram áreas cementárias reparadas, com numerosos feixes colágenos no ligamento periodontal e presença suave de células inflamatórias. Nos grupos II e IV as áreas de reabsorção cementária não estavam reparadas, com reduzida presença de células e fibras e presença de células inflamatórias. Na análise semi-quantitativa do selamento biológico apical houve diferença significante (p<0,0001) entre os grupos I e II; e entre os grupos III e IV (p<0,0001). A análise em microscopia de fluorescência evidenciou diferença significante entre os grupos, após 120 dias (p=0,0004) e após 180 dias (p=0,0081), sendo que os grupos I e III apresentaram lesões periapicais menores. A porcentagem de redução radiográfica das lesões evidenciou diferença significante entre os grupos (p<0,05), com maior porcentagem de redução para os grupos I e III. Com relação à análise imunohistoquímica, nos grupos I, II e IV, as marcações para RANK, RANKL e OPG indicaram sinalização pró-reabsortiva, embora a marcação para RANKL no grupo I tenha sido pouco intensa. Já no grupo III, as marcações evidenciaram ocorrência de neoformação óssea. Conclusão: O tratamento em duas sessões com o uso de curativo de demora à base de hidróxido de cálcio promoveu maior redução no tamanho das lesões periapicais e estágio mais avançado de reparo, evidenciado pelos melhores resultados histopatológicos, imunohistoquímicos e radiográficos, em comparação ao tratamento em uma única sessão com utilização do protocolo de aPDT avaliado. / To evaluate one-session endodontic treatment with aPDT and two-session treatment with calcium-hydroxide (CH)-based dressing in dog\'s teeth with apical periodontitis. Methods: After experimental induction of apical periodontitis, 48 teeth were randomly assigned to the following groups: Group I (one-session treatment with aPDT 120 days); Group II (one-session treatment with aPDT 180 days); Group III (two-session treatment with CH-based dressing -120 days) and Group IV (two-session treatment with CH-based dressing -180 days). The animals were euthanized after 120 and 180 days. After histotechnical processing, microscopic and radiographic analyses were performed. Data were analyzed by Kruskal-Wallis and Fishers exact tests (=0.05). Results: In the microscopical analysis, Groups I and III presented repaired cemental areas, with various colagen bundles in the periodontal ligament and mild presence of inflamatory cells. In the groups III and IV the present resorbed cemental areas were not repired, with reduced number of cells and fibers and the presence of inflamatory cells. The semi-quantitative analysis of the apical clousure, there was a significant difference (p<0.0001) between groups I and II; and between groups III and IV (p<0.0001). In the fluorescence microscopy analysis, there was a significant difference between groups, aftter 120 days (p=0.0004) and after 180 days (p=0.0081). The groups I and III presented smaller periapical lesions. The percentage of radiographic reduction of lesions demonstrated a significant difference between groups (p<0.05) with a higher reducton in group I and II. Regarding the immunohistochemistry analysis, in the groups I, II and IV, RANK, RANKL and OPG staining indicated pro-resorption signaling; although the RANKL immunostaining in the group I were not intense. In the group III, the immunostaining demonstrated the occurrence of bone neoformation. Conclusion: Two-session treatment with CH based promoted more reduction in the periapical lesion size and more repair advanced stage, highlighting better histopathological, immunostaining and radiographic results in comparison with one-session treatment with aPDT protocol used.
170

Avaliação da qualidade do selamento apical de obturações endodonticas em dentes humanos com canais radiculares preparados com diferentes soluções irrigadoras / An evaluation of the apical sealing ability in endodontically treated human teeth with root canal prepared using differents irrigants

Velasco, João Odilo 06 November 2002 (has links)
Orientador: Francisco Jose de Souza Filho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-02T02:43:04Z (GMT). No. of bitstreams: 1 Velasco_JoaoOdilo_D.pdf: 2978488 bytes, checksum: f6f430cc9935683be2970d24cd33c8c6 (MD5) Previous issue date: 2002 / Resumo: Este trabalho teve por objetivo estudar in vitro a qualidade do selamento apical de obturações endodônticas realizadas em 72 dentes humanos com canais radiculares preparados, utilizando-se a técnica de instrumentação coroa-ápice com auxílio de instrumentos rotatórios e instrumentação manual do terço apical, usando hipoclorito de sódio 5,25% ou gluconato de clorexidina 2% gel como substâncias químicas irrigadoras e irrigação final com diferentes soluções ou combinações de diferentes soluções. Os canais radiculares foram obturados pela técnica da compressão hidráulica vertical e cimento Endomethasone. Para a avaliação da microinfiltração apical, os dentes foram impermeabilizados com esmalte para unha, com exceção de 2mm apicais, mergulhados em tinta Nankin, submetidos a vácuo e deixados no corante por um período experimental de 7 dias a 37° C. Após a remoção da película de esmalte, as raízes foram diafanizadas e, a seguir, analisadas sob lupa estereoscópica. A qualidade do selamento apical foi avaliada em relação à penetração ou não do corante entre as paredes do canal e a obturação ou entre os componentes da obturação. Os resultados obtidos foram analisados estatisticamente segundo o teste de hipótese de Student a um nível de significância p=0,05,não tendo sido observada diferença estatística na qualidade do selamento apical em dentes com canais radiculares preparados com as diferentes soluções irrigadoras analisadas / Abstract: The objective of this study was to determine in vitro the apical sealing ability in endodontical/y treated human teeth. Seventy-two root canais were prepared by crown-down technique using 5,25% NaOCI or 2% chlorhexidine gluconate gel as an endodontic irrigant between each instrument and a final flushing of various solutions or combinations of solutions. These canais were then filled by an single gutta-percha cone and Endomethazone sealer. The teeth were coated with nail varnish layers, except the apical 2 mm, then immersed in black India ink under vacuum conditions during 10 minutes and stored for 7 days at 37° C. The specimens were rinsed under tap water and the vamish removed. The roots were subsequently cleared and examined at 15 magnification with a stereomicroscope. The apical sealing ability was determined by the penetration of ink beyond the end of the preparation. Data were analyzed statistically using the Student's test. The levei of significance was set at p = 0,05. The results obtained indicated that there is no difference in the apical sealing quality of endodontically treated teeth prepared with differents irrigants / Doutorado / Endodontia / Doutor em Clínica Odontológica

Page generated in 0.0463 seconds