• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 309
  • 66
  • 8
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 388
  • 99
  • 78
  • 56
  • 54
  • 54
  • 52
  • 38
  • 38
  • 34
  • 29
  • 29
  • 28
  • 25
  • 24
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Avaliação dos parâmetros de soldagem na resistência ao desgaste abrasivo de revestimentos duros / Evaluation of the welding variables on the abrasion resistance of hardfacings

Dias, Marcia Fernanda Martins 11 November 2002 (has links)
Este trabalho apresenta uma análise das condições de soldagem sobre o desgaste abrasivo de um revestimento duro. O revestimento foi feito pela deposição metálica por arco submerso variando os parâmetros de soldagem e utilizando fluxos comerciais. Foram utilizados dois conjuntos de parâmetros de soldagem (conjunto 01 com velocidade de soldagem de 55 cm/min, extensão do eletrodo de 35,0 mm, tensão de 30V, corrente de 450A e o conjunto 02 com velocidade de soldagem de 50 cm/min, extensão do eletrodo de 25,5 mm, tensão do arco de 26V e corrente de 440A) e quatro fluxos comerciais (identificados como E, M, L e R) formando assim oito condições de soldagem. Foram feitas duas camadas com três cordões de solda cada sobre uma chapa base de aço SAE 1020. Corrente contínua com polaridade direta (CC-) foi utilizada em ambas condições. A resistência ao desgaste abrasivo a baixa-tensão foi avaliada pelo ensaio de desgaste do tipo Roda de borracha/areia seca conforme a norma ASTM G65-94. A análise microestrutural foi feita por microscopia óptica e a análise da região desgastada por microscopia eletrônica de varredura. A resistência ao desgaste abrasivo dos revestimentos do conjunto 01 foi superior em comparação com os revestimentos do conjunto 02, para todos os fluxos utilizados. Os fluxos E e R proporcionaram os melhores desempenho e a martensita de agulhas foi a microestrutura com a qual foram obtidos os melhores resultados de desgaste abrasivo a baixa-tensão neste estudo realizado. / This work presents an analysis of the welding conditions and its effects in the abrasive wear of hardfacings. The hardfacings were obtained by submerged arc surfacing. The welding variables were changed and the commercials fluxes were used. Two groups of welding variables were used (group 01: a traveI speed of 55 cm/min, an electrode extension of 35,0 mm, a voltage of 30V and an amperage of 450A; group 02: a traveI speed of 50 cm/min, an electrode extension of 25,0 mm, a voltage of 26V and an amperage of 440A) and four commercials fluxes (E, M, L e R designated) establishing eight welding conditions. Double-Iayered ot three beads were deposited (applied) on a SAE 1020 base metal plate. Direct current electrode negative polarity (CC-) were used in both groups of welding. The low stress abrasion resistance evaluation was carried out by dry sand/rubber wheel apparatus according to the ASTM G65-94. The microstructural analysis were done by optical microscopy and the worn surface analysis were done by scanning electronic microscopy. The abrasion resistance of the group 01 was superior as compared to the group 02, independent of the fluxe was used. The fluxes E and R presented the best results and the befter abrasion resistant microstructure was lath martensite.
132

Efeito do resfriamento no teor de oxigênio na soldagem com eletrodo revestido E7018 utilizando experimentos fatoriais. / Effect of cooling on oxygen content on welding with E7018 covered electrode using factorial experiments.

Souza, Gustavo José Suto de 08 June 2018 (has links)
Na manutenção de tubulações e dutos de aços de alta resistência baixa liga (ARBL), os reparos são executados com eletrodo revestido e com o equipamento operação, com o intuito de reduzir custos com paradas. Nesta aplicação, os gradientes de temperatura são mais elevados quando comparados com sondagens realizadas ao ar, o que pode levar à redução das propriedades mecânicas nessas juntas soldadas e causar maiores impactos financeiros ou mesmo ambientais. No metal depositado resultante do eletrodo revestido AWS E7018-1, usualmente utilizado no reparo de dutos de aços ARBL, as propriedades mecânicas têm forte relação com a ferrita acicular, microestrutura que ocorre intergranularmente, nucleando preferencialmente em inclusões do metal depositado. O objetivo desse trabalho é analisar a influência de diferentes condições de soldagem e de resfriamento sobre o teor de oxigênio e sobre a microdureza do metal depositado resultante do uso de eletrodos revestidos AWS E7018-1, usando técnicas de planejamento experimental como as metodologias Taguchi e experimentos fatoriais. Usando o método Taguchi foi possível observar que os três fatores (fabricante do eletrodo, corrente de soldagem e condição de resfriamento) influenciam no teor de oxigênio e que o fornecedor do eletrodo é o fator com maior efeito sobre a resposta, seguido pela corrente de sondagem. Com relação à etapa de experimentos fatoriais mapas operacionais para o teor de oxigênio e microdureza dos cordões de solda foram construídos. Foi possível observar que a corrente de soldagem tem efeito mais impactante que a taxa de resfriamento sobre o teor de oxigênio e a microdureza. / Covered electrodes had been developed at the beginning of the 20th Century and, despite the evolution of several welding processes, the shielded metal arc welding (SMAW) still find widespread application, even within the oil and gás industry, e.g. repairing of high strength low (HSLA) steel pipes. The pipe repairing is carried out during its operation (in order to reduce costs) and, therefore, the temperature gradients in the base metal are higher compared to removing the pipe system from service. This could lead to reducing mechanical properties in these welded joints that could cause higher financial or even environmental impacts. In the low carbon weld metal (e.g. AWS E7018-1 electrode is usually employed in HSLA pipe repair). The mechanical properties have a strong relationship with the acicular ferrite fraction, which occurs intergranularly and nucleating preferentially in inclusions within weld metal. The objective of this work is to analyze the influence of different welding and cooling conditions on the oxygen content ando n the mechanical properties of the weld metal from the AWS E7018-1 covered electrodes, using design of experiments techniques as Taguchi\'s method and response surface methodology (RSM). Using the Taguchi\'s method, it was possible to observe that three factors (namely electrode supplier, welding current and cooling condition) have influence on the oxygen content and the electrode supplier is the factor with the greatest effect on the response, followed by the welding current. Regarding to the factorial experiment, operational maps for the oxygen content and microhardness of the weld beads were constructed. It was possible to observe that the welding current hás a more impactful effect than the cooling rate on the oxygen content and microhardness.
133

Avaliação da composição elementar de filmes finos de ligas metálicas depositados por Arco Catódico Filtrado em Vácuo utilizando RBS e EDS quantitativo / Evaluation of the elemental composition of alloy thin films deposited by Filtered Cathodic Vacuum Arc using RBS and quantitative EDS analysis

Oblitas, Raissa Lima de 26 September 2016 (has links)
Devido à relevância de filmes finos, as técnicas que são utilizadas para produzi-los e também para caracteriza-los tem se tornado importante. Neste contexto, foram analisados filmes finos de até 100 nm, de duas ligas metálicas (cromel e alumel), obtidos a partir da deposição por plasma de Arco Catódico Filtrado em Vácuo (Filtered Cathodic Vacuum Arc - FCVA). O objetivo deste projeto foi avaliar a similaridade em composição elementar entre os materiais utilizados para deposição, que operam como cátodos, e os filmes finos depositados, a partir de medições obtidas pela técnica de microanálise quantitativa Energy Dispersive Spectroscopy (EDS). Para comparação entre resultados e apreciação de compatibilidade, foi realizada avaliação estatística considerando o Teste t, no qual a estatística do teste é dada pela Distribuição t de Student, adotando nível de significância de 5%. Os valores obtidos por EDS Quantitativo para os cátodos foram de (em wt%) (90,3 ± 0,5)% de Ni e (9,72 ± 0,19)% de Cr para o cromel e (95,1 ± 0,8)% de Ni, (2,02 ± 0,14)% de Mn, (1,65 ± 0,04)% de Si e (1,15 ± 0,05)% de Al para o alumel. Já para os filmes finos, foram de (90,2 ± 0,5)% de Ni e (9,8 ± 0,5)% de Cr para o cromel e (95,2 ± 0,4)% de Ni, (2,8 ± 0,4)% de Mn, (0,77 ± 0,17)% de Si e (1,08 ± 0,09)% de Al para o Alumel, ambos apresentando compatibilidade com as medidas por Rutherford Backscattering Spectrometry (RBS) - técnica comumente utilizada para este tipo de espécime. Verificou-se que a composição elementar do filme fino de cromel não apresentou diferença significativa com o cátodo da mesma liga. Entretanto, para o filme fino de alumel, houve evidências de diferença significativa com relação ao cátodo, apontada pelo elemento silício. / Due the relevance of thin films, the techniques used to produce and also to characterize them has become important. In this context, it was analyzed thin films up to 100 nm of two alloys (Chromel and Alumel) obtained by plasma deposition using Filtered Cathodic Vacuum Arc (FCVA). The objective of this project was to evaluate the similarity in elemental concentration of the materials used for deposition, which act as cathodes, and the deposited thin films, through measurements obtained by quantitative microanalysis technique Energy Dispersive Spectroscopy (EDS). In order to compare results and compatibility assessment was performed statistical analysis considering the t-test in which the test statistic is given by the Student\'s t - distribution, adopting a significance level of 5%. The values obtained by Quantitative EDS for the cathodes were (in wt%) (90.3 ± 0.5)% of Ni and (9.72 ± 0.19)% of Cr for the Chromel and (95.1 ± 0.8)% of Ni, (2.02 ± 0.14)% of Mn, (1.65 ± 0.04)% of Si and (1.15 ± 0.05)% of Al for the Alumel. As for the thin films, they were (90.2 ± 0.5)% of Ni and (9.8 ± 0.5)% of Cr for the Chromel and (95.2 ± 0.4)% of Ni, (2.8 ± 0.4)% of Mn, (0.77 ± 0.17)% of Si and (1.08 ± 0.09)% for Al Alumel, both featuring compatibility with the measures by Rutherford Backscattering Spectrometry (RBS) - technique commonly used for this type of specimen. It was verified that the elemental concentration of the thin film of Chromel presented no significant difference with the cathode of the same alloy. However, for the Alumel thin film, there was evidence of a significant difference with respect to the cathode, appointed by element Silicon.
134

Avaliação dos arcos dentais e das estruturas miofuncionais orais, em função do uso e tipo de chupeta, em crianças com dentição decídua completa. / Evaluation of the dental arches and myofunctional oral structures in children with complete primary dentition, according to pacifier use and type.

Zardetto, Cristina Giovannetti Del Conte 27 October 2000 (has links)
Neste estudo avaliou-se as características dos arcos dentais e das estruturas miofuncionais orais de 61 crianças na faixa etária de 36 a 60 meses que apresentavam hábito de sucção de chupeta ou não, e a relação entre o uso e tipo de chupeta com diversos aspectos comportamentais da mãe, grau de escolaridade materna e renda familiar. Estes últimos três aspectos foram avaliados por meio de questionário distribuído à s mães, e as características dos arco dentais e das estruturas miofuncionais orais por meio de exame clínico. As crianças foram dividas em três grupos conforme o uso e tipo de chupeta: 1. grupo que nunca sugou chupeta, 2. grupo que sugava somente a chupeta anatômica (ortodôntica) e, 3. grupo que sugava somente a chupeta convencional. Não foi encontrada associação estatisticamente significante entre o uso da chupeta e o sexo e número de irmãos da criança, renda familiar e grau de estudo formal da mãe. Verificou-se que o período de aleitamento materno menor e o fato de ter tido uma ou mais chupetas já no enxoval do bebê, favoreceram o uso da chupeta. Não foi encontrada relação estatisticamente significante entre o tipo de arco dental, relação terminal dos segundos molares decíduos, linha média e espaço primata entre os três grupos avaliados. Notou-se que a relação canina Classe II foi significantemente maior nas crianças que sugavam chupeta do que naquelas que não tinham este hábito. Constatou-se que tanto a chupeta anatômica como a convencional, favoreceram o desenvolvimento da mordida aberta anterior e cruzada posterior. Não houve diferença estatisticamente significante entre as médias de mordida aberta anterior nas crianças que usavam chupeta convencional ou anatômica (p=0,344). A prevalência da mordida cruzada posterior foi estatisticamente maior nas crianças que sugavam a chupeta convencional do que naquelas que sugavam a anatômica (ortodôntica) ou não tinham este hábito (p=0,010). As distâncias intercaninas do arco superior foram significantemente menores nas crianças que sugavam chupeta do que naquelas sem este hábito. Já nas distâncias intercaninas do arco inferior, não houve diferença entre os três grupos. A dimensão da sobressaliência foi maior em ambos os grupos de chupeta quando comparados ao grupo sem hábito de sucção (p=0,000). Em relação ao modo de sugar a chupeta, observou-se que a sobressaliência nas crianças que sugavam sempre a chupeta (p= 0,021), foi estatisticamente maior do que daquelas que sugavam às vezes . Das estruturas miofuncionais orais avaliadas, houve associação estatisticamente significante entre a mobilidade da bochecha (p=0,022) e formato do palato duro (p=0,042) com o uso e tipo de chupeta; sendo que as crianças que nunca sugaram chupeta, apresentaram uma prevalência maior de normalidade destas duas estruturas do que aquelas que sugavam chupeta. / This study evaluated through clinical examination the characteristics of the dental arches and myofunctional oral structures of 61 children aged 36- to-60-months, who either had pacifier-sucking habit or did not. Pacifier use and type was compared to family income and mother’s attitudes and educational level. This was assessed by a questionnaire distributed to the mothers. The children were divided into three groups: 1. those who never had pacifier sucking habit, 2. those who only used anatomic or orthodontic pacifier, and 3. those who only used conventional pacifier. No statistically significant relationship was found between pacifier use and the family income, mother´s educational level, and child´s sex and number of siblings. The children who were breastfed for a smaller period of time and had one or more pacifiers on his/her layette had higher prevalence of pacifier sucking habit. No statistical significant relationship was found between arch type (Type I or Type II according to Baume´s classification), terminal plane relationship of second primary molars, medline and primate spaces among the three groups studied. Class II primary canine relationship was significantly greater among pacifier users than among those without this sucking habits. It was observed that both, the anatomic (orthodontic) and conventional pacifiers lead to anterior open bite and posterior crossbite. No significant difference was found between the ones who used the anatomic (orthodontic) pacifier or the conventional one, in respect to the mean openbite (p=0,344). Compared to children without sucking habit, children with pacifier habit had a greater mean overjet (in milimeters) (p=0,000). Posterior crossbite was statistically different among the children who used the conventional pacifier when compared to the other two groups (p=0,010). The upper intercanine distance was significantly smaller among those who had pacifier sucking-habit when compared to those habit-free, but no significant difference was found among the three groups with respect to the lower intercanine distance. Among the myofunctional oral structures evaluated, the ones that demonstrated statistical difference among the three groups were the cheek mobility (p=0,022) and the hard palate shape (p=0,022); being that the group of children who never sucked a pacifier, showed a higher prevalence of normality of these two structures than the ones who had a pacifier sucking habit. In regards to how frequent the child sucked the pacifier throughout the day, it was seen that those who “always sucked" had a significantly greater overjet (p=0,021), than those who “suck sometimes" or “just held" the pacifier in the mouth.
135

Avaliação comparativa da Borda WALA em mandíbulas secas e modelos e da sua mensuração em radiografias oclusais e tomografias / A comparative assessment of the WALA ridge in dissected mandibles and cast models as well as its measurement in occlusal radiographies and tomographies

Moura Neto, Gastão 06 May 2010 (has links)
Introdução: a determinação da Borda WALA em modelos de gesso permitia defini-la como uma linha imaginária utilizada no planejamento, seguimento e finalização de casos clínicos. Procurou-se determinar a Borda WALA em modelos de gesso de pacientes ortodônticos, mandíbulas secas, radiografias oclusais e cortes tomográficos dos pacientes e mandíbulas respectivas. O objetivo foi detectar a viabilidade de mensurar e determinar, por um método reproduzível, a Borda WALA em radiografias oclusais e cortes tomográficos. Metodologia: foram utilizados modelos, radiografias oclusais e tomografias de feixe cônico de 12 pacientes ortodônticos, e 12 mandíbulas e suas respectivas radiografias oclusais e cortes tomográficos. As mensurações tomográficas foram realizadas, em todos os dentes, do ponto mais vestibular das raízes dentárias no nível cervical até a parte mais externa da cortical óssea vestibular. Nas mandíbulas secas e nos modelos, as medidas verticais partiam do ponto EV até a linha de grafite que determinou o ponto vestibular mais externo. Resultados: os arcos correspondentes à Borda WALA obtidos nos modelos de gesso e nas mandíbulas secas se equivaleram em sua forma, sendo um pouco menores, em sua dimensão, nos modelos. Os arcos obtidos a partir das mensurações realizadas em radiografias oclusais e cortes tomográficos se equivaleram, em sua forma, nos modelos e mandíbulas, com correlação fortemente positiva, detectada pelo Coeficiente de Correlação de Pearson. Conclusões: 1. a Borda WALA não representa uma estrutura anatômica, mas uma medida/anagrama/referência a ser mensurada e utilizada nos tratamentos ortodônticos e ortopédicos; 2. a Borda WALA não deve ser considerada uma linha imaginária, mas um arco a ser determinado por medidas que devem servir de parâmetro nas correções das alterações da oclusão e alinhamento dos dntes inferiores; 3. em seu contorno e forma, as medidas obtidas nos modelos e nas mandíbulas, assim como nas radiografias oclusais e tomografias de feixe cônico, se equivaleram estatisticamente. Nas radiografias oclusais dos pacientes, houve dificuldades técnicas para a obtenção de imagens que permitissem uma mensuração precisa na determinação da Borda WALA. Nos cortes tomográficos, as medidas realizadas para determinação da Borda WALA reproduziram, com coeficiente de correlação fortemente positivo, a dimensão e a forma obtidas em medidas nos modelos de gesso e nas mandíbulas secas. Em suma, a determinação da Borda WALA a partir de cortes tomográficos transversais no nível cervical dos dentes inferiores é viável, pois a dimensão e a forma do arco obtido se equivalem estatisticamente ao arco obtido pelas medidas realizadas em modelos de gesso e mandíbulas secas. / Introduction: The WALA ridge is an imaginary line determined in cast models and used as reference for orthodontic treatment planning, execution and finalization. In the following study, the WALA ridge was defined in cast models of orthodontic patients, dissected mandibles, occlusal radiographies and tomographic slices of patients and respective mandibles aiming to find a reproducible method for determining the WALA ridge in occlusal radiographies and tomographic slices. Methodology: The sample comprised 12 cast models, occlusal radiographies and cone beam tomographies of orthodontic patients and 12 dissected mandibles, their respective occlusal radiographies and tomographic slices. Tomographic measurements were made in all teeth from the most buccal point of dental roots on their cervical level until the most external and anterior cortical line of bone. Vertical measurements on dissected mandibles and cast models were taken from FA point until the pencil line that determined the most external edge of bone around mandibular teeth. Results: The arches corresponding to the WALA ridge obtained from cast models and dissected mandibles were equivalent in form but a little smaller in size for cast models. The arches obtained from occlusal radiographies and tomographic slices were equivalent in form to the ones obtained from models and dissected mandibles, with a high positive correlation of proportion statistically confirmed by Pearsons coefficient. Conclusion: 1. The WALA ridge is not an anatomical structure, but a measurement/anagram/reference to be measured and used during orthodontic and orthopedic treatment. 2. The WALA ridge should not be considered an imaginary line, but an arch to be determined by measurements and used as parameter when correcting the occlusion of misalignment of inferior teeth; 3. The measurements obtained from models and dissected mandibles, as well as from occlusal radiographies and cone beam tomographies were equivalent in shape and form. Obtaining the WALA ridge from occlusal radiographies in patients involve technical difficulties to acquire a good image for precise measurement. Tomographic measurements to determine the WALA ridge were reproducible, with a high positive correlation coefficient to the dimension and form obtained from cast models and dissected mandible measurements. To sum up, determining the WALA ridge from tomographic transversal slices on the cervical level of inferior teeth is viable, since the dimension and arch form are statistically equivalent to the arch form obtained from cast models and dissected mandibles.
136

Avaliação do posicionamento de caninos superiores permanentes na fase da dentadura mista em relação à largura do arco dentário e ao espaço na região anterior / Evaluation of the maxillary canines position in mixed-dentition and width and anterior space relationship

Suga, Selma Sano 19 March 2008 (has links)
Este estudo avaliou o posicionamento de caninos superiores permanentes em relação à largura do arco dentário superior e ao espaço na região anterior em pacientes na fase da dentadura mista. Foram analisados radiografias panorâmicas e modelos de estudo pré-tratamento de pacientes sem caninos deslocados (n = 68; 34 do gênero masculino; 34 do gênero feminino). A amostra foi dividida em idade e gênero. A largura do arco dentário e o espaço na região anterior entre os incisivos permanentes foram medidos. A posição e a inclinação do canino na radiografia panorâmica foram avaliadas em relação à linha mediana. Os resultados deste estudo mostram que não houve diferenças no posicionamento dos caninos permanentes em relação às variáveis analisadas. A média da angulação do canino superior em relação à linha mediana foi 6,2o e 10o para o gênero feminino e 9,2o e 11o para o masculino, respectivamente para o lado direito e esquerdo. / This study investigated the correlation between maxillary dental arch width, anterior space and the position of canines in patients during the mixed-dentition stage. Pretreatment Panoramic radiographs and dental casts were evaluated of randomly selected patients in the mixed dentition without maxillary canines displaced (n = 68; male, 34; female, 34). This sample was matched according to sex and age. Arch widths between the maxillary canines deciduous and anterior space between permanent incisors were measured and recorded. The position and inclination of canine on panoramic radiography was investigated. The results of this study showed that there are similarities in the position of the permanent canines in all cases and in both gender. The average of the canine\'s angulation to the mid-sagital plane was 6,2o and 10o for female and 9,2o and 11o for male, respectively to the right and left side.
137

Influência da inclinação do garfo de mordida do arco facial na montagem do modelo superior em articulador semi-ajustável do tipo arcon e não-arcon / Influence of the inclination of the face-bow\'s bite fork on mounting of maxillary cast in arcon and nonarcon semiadjustable articulators

Bellodi, Daniele Manfrim 15 August 2008 (has links)
Durante o processo ensino/aprendizagem em Odontologia, é comum a ocorrência de inclinações do garfo de mordida em relação ao plano oclusal maxilar dos pacientes durante a tomada do arco facial realizada por alunos. Este trabalho avaliou a influência das inclinações do garfo de mordida para anterior e para posterior em relação ao plano oclusal na montagem do modelo maxilar em articuladores semi-ajustáveis do tipo arcon e não-arcon. Foram obtidos vinte modelos do arco maxilar de vinte pacientes, nos quais dois pontos foram marcados: um na aresta vestibular do canino direito e outro na aresta vestibular da cúspide mésio-vestibular do primeiro molar direito. Os registros no garfo de mordida foram realizados em três posições: garfo de mordida paralelo ao plano oclusal dos modelos, inclinado para anterior e para posterior (ambas 5º). Cada posição foi repetida cinco vezes, sendo o conjunto articulador/arco facial fixado em suporte especial para registro fotográfico. Cada fotografia foi levada ao programa Auto CAD, obtendo-se linhas de referências para a coleta de cinco medidas (uma angular e quatro lineares). Os dados obtidos foram submetidos à análise estatística paramétrica (Análise de Variância). Os resultados indicaram não haver diferença estatisticamente significante para inclinações do garfo de mordida tanto para anterior como para posterior em relação ao plano oclusal do modelo tanto para o articulador semi-ajustável do tipo arcon como para o não-arcon. O trabalho sugere que pequenas inclinações do garfo de mordida não comprometem a tomada do arco facial e sua transferência para articuladores semi-ajustáveis. / During the process teaching/learning in Dentistry, the occurrence of adverse inclinations of the bite fork concerned to maxillary occlusal plane of patients are current during the face-bow taking performed by students. This study evaluated the influence of the inclinations of bite fork to anterior and posterior related to oclusal plane on mounting of the maxillary cast in arcon and nonarcon semiadjustable articulators. Twenty casts of the maxillary arch from twenty patients were obtained, on which two points were marked: one on the vestibular edge of the right canine and another on the vestibular edge of mesiovestibular cusp of the right first molar. The records in the bite fork were made in three positions: the bite fork parallel to the castss plane occlusal, inclined to anterior and to posterior (both 5°). Each position was repeated five times, being the articulator/face-bow set fixed in special support for photographic register. Each photograph was introduced in Auto CAD program, resulting in lines of references for the collection of five measures (one angular and four linear). The data were subjected to statistical analysis parametric (Analysis of Variance). The results showed no significant statistical difference for inclinations of the bite fork to both anterior and to posterior related to the castss occlusal plane for the arcon and nonarcon semiadjustable articulators. The work suggests that small inclinations of bite fork do not compromise the face-bow taking and its transfer for the semiadjustable articulators.
138

Efeitos do fluxo ativado como recebido na soldagem a arco submerso com adição de pó de ferro / not available

Buttignon, Isabel Cristina 19 July 2001 (has links)
O objetivo deste trabalho foi estudar as propriedades mecânicas do metal como soldado usando fluxo ativado na condição como recebido. Foram utilizadas cinco chapas base, sendo quatro delas de aço do tipo alta resistência e baixa liga (ABRL) e uma de aço carbono comum SAE 1020, que foram soldadas usando um único passe. O eletrodo utilizado foi o arame EM 12K , diâmetro de 4 mm e pó de ferro 400. As condições de soldagem utilizada foram: tensão de 34V, corrente de 660A, velocidade de soldagem de 30 cm/mim por minuto e uma adição de pó metálico de 373 g/m. Estas condições produzem um aporte de calor de 4,5 kJ/mm e uma diluição da chapa base em torno de 43%. Os ensaios mecânicos realizados forma de dureza, de tração e de impacto. A natureza das inclusões não metálicas foi investigada por microscopia eletrônica de varredura e análise por Energy Dispersive X RAY (EDS). Os resultados mostraram que as condições do fluxo e a diluição da chapa base alteraram a química nos metais como soldados, principalmente o oxigênio, isto permitiu mudanças significativas na temperabilidade. Como resultado as percentagens das microestruturas foram bastante alteradas principalmente na ferrita acicular, ocasionando mudanças nas propriedades mecânicas de dureza, tração e impacto. / The objective of this work was to study the properties of the metal as welded using activated flux in the condition as received. Five base plates, four of which were HSLA steel and one SAE 1020, that were welded using a single pass. EM 12K electrode and 400 metallic powder were used. The conditions for welding were: voltage 34V, current 660A, welding speed 30 cm/min and addition of metallic powder 373 Kg/M. These conditions produced a heat input of 4,5 kJ/mm and dilution in the base plate around 43%. Mechanical tests of hardness, impact resistance and tensile strength were carried out. The nature of non-metallic inclusions was investigated by scanning electron microscopy and analysis by Energy Dispersive X-Ray (EDS). The results showed that the conditions of the flux and the dilution of the base plate changed the chemical compositions in the metal as welded, mainly oxygen, which altered significantly the hardenability. As a result, the percentage of the microstructures changed, specially for acicular ferrite, allowing for changes in mechanical properties of hardness, impact resistance and tensile strength.
139

Estudo comparativo da reprodutibilidade do arco facial e de um novo dispositivo com nível de bolha para montagem de modelos maxilares em articulador semi-ajustável / Comparative study of the reproducibility of the face bow and a new bubble level device for mounting maxillary casts semi-adjustable articulator

Cintra, Marina de Godoy Almeida 28 April 2015 (has links)
O arco facial tem seu uso descrito na literatura desde o início do século 20, e atualmente sua eficácia e precisão são controversas. Publicações recentes mostram que a sua reprodutibilidade é passível de erros. Este estudo teve como objetivo comparar a reprodutibilidade do arco facial com a de um novo dispositivo desenvolvido com nível de bolha para a montagem de modelos de gesso em articuladores semi-ajustáveis, por meio da análise de medidas realizadas com a Mesa de Erickson. Os modelos de gesso foram obtidos com moldes de alginato e montados em articulador semi-ajustável marca Bio-art, modelo a7 Plus. A avaliação da reprodutibilidade foi realizada em 10 participantes, com a obtenção de três montagens de seus modelos maxilares, sendo a primeira com o arco facial, a segunda com o dispositivo com nível de bolha estando o participante sentado e a terceira com o dispositivo com nível de bolha estando o participante em pé, cada método foi aferido 3 vezes, por 3 examinadores diferentes. Para cada montagem foram realizadas cinco medidas a saber: a) nas cúspides dos primeiros molares superiores de cada lado (dentes 16 e 26), b) cúspides dos caninos superiores de cada lado (dentes 13 e 23) e c) ponto interincisivo, localizado na linha média. Os valores obtidos foram submetidos ao Cálculo do Erro Técnico da Medida e ao Coeficiente de Variação interexaminador. O presente trabalho concluiu que o arco facial tem uma margem de erro em medidas repetidas maior do que o novo dispositivo desenvolvido. O novo dispositivo mostrou-se mais confortável para os participantes, mas necessita mais testes para avaliarmos sua eficiência. / The face bow has been described in the literature since the early 20th century, and currently its effectiveness and accuracy are controversial. Recent publications show that the reproducibility is error-prone. This study aimed to compare the reproducibility of the face bow with a new device developed with bubble level for the assembly of plaster models in semi-adjustable articulators, through the analysis of measurements performed with Erickson table. The plaster models were obtained with alginate molds and mounted on semi-adjustable articulator brand Bio-art, a7 Plus model. Evaluation of reproducibility was conducted in 10 participants, obtaining three assemblies of their maxillary casts, the first one with the face bow, the second with the bubble level device with the participant being seated and the third level with the device bubble being the participant standing, each method was measured 3 times by 3 different examiners. For each assembly five measurements were performed as follows: a) in the cusps of the upper first molars on each side (teeth 16:26), b) cusps of upper canines on each side (teeth 13:23) and c) interincisal point, located in midline. The values obtained were subjected to measurement of the Technical Error Calculation and inter Coefficient of Variation. This study concluded that the face bow has a margin of error in repeated measurements greater than the newly developed device. The new device was more comfortable for the participants, but it needs more testing to evaluate their efficiency.
140

Temporal pattern in the muscles of the upper limbs and the trunk in the archery / Padrão temporal nos músculos dos membros superiores e do tronco no tiro com arco

Machado, Nadjila Tejo 15 March 2018 (has links)
Central nervous system stabilizes body in disturbance by means of anticipatory and compensatory postural adjustments to maintain stable position. Disturbance effects in joint are reduced by activation of agonist and antagonist forearm muscles, the muscles allow consistency by steady posture during shot. Studies showed the importance of posture in the shot, but without focus on the anticipatory and compensatory postural adjustments. The objective of this study was to analyze an electrical activity of archers during the shot an arrow with the bow. Participants consisted of 10 archers of the Brazilian National Team of archery. Electromyography captured electrical activity in 12 muscles. Accelerometer in handle indicated the beginning of the movement. Temporal pattern separated in 500 milliseconds pre and post clicker fall. Protocol started by Maximal Voluntary Isometric Contraction of 12 muscles. Archers release 3 blocks of 6-arrows in warm-up. Archers throw arrows for 12 blocks with 6-arrows with interval of 20 minutes after the block 6. One-way Analysis of Variance and Tukey Test compared temporal pattern. One-way Analysis of Variance with repeated measures compared temporal pattern and 6-arrows. Results showed that all muscles (except m. Lumbar Multifidus) increase in their demand with the proximity of the arrow release. The muscles decreased their activity due to reduced demand in compensatory and modulation phase. Comparison between 12 blocks of 6-arrows showed 3 ways of temporal pattern: 1) muscles affected by phases and muscles affected by all/any phases in the blocks of 6-arrows, 2) muscles affected by phases and muscles unaffected by all/any phases in the blocks of 6-arrows and 3) muscles unaffected by phases and muscles affected by all phases in the blocks of 6-arrows. Muscles were not affected by phases/blocks maintain muscle activity along intervals by similar muscular demand. Cross-correlation between motor muscles showed that forearm muscles obtained inverse relationship between them. Other motor muscles were strong correlation between them. Postural muscles m. Lumbar Multifidus, m. Latissimus Dorsi, m. Upper Trapezius were strong correlation with all postural muscles. Motor and postural muscles showed that m. Triceps Brachii, m. Pectoralis Major Clavicular Head and m. Posterior Deltoid showed strong correlation with all postural muscles. In conclusion, muscle activity increases in anticipatory phase and muscle activity decrease after clicker fall. There are 3 ways to compare phases and blocks: affected by phases and 1) muscles affected/2) muscles unaffected by all/any phases in the blocks of 6-arrows and 3) muscles unaffected by phases and affected by all phase in the blocks of 6-arrows. Correlation in motor muscles showed that forearm muscles obtained inverse relationship between them. Postural muscles m. Lumbar Multifidus, m. Latissimus Dorsi, m. Upper Trapezius were strong correlation with all postural muscles. Motor and postural muscles showed that m. Triceps Brachii, m. Pectoralis Major Clavicular Head and m. Posterior Deltoid showed strong correlation with all postural muscles / O sistema nervoso central estabiliza o corpo na perturbação por meio de ajustes posturais antecipatórios e compensatórios para manter a postura estável. Os efeitos da perturbação na articulação são reduzidos pela ativação dos músculos agonistas e antagonistas do antebraço, os músculos permitem a consistência no tiro pela postura estável. Os estudos mostram a importância da postura no tiro, mas não se concentrarem nos ajustes posturais antecipatórios e compensatórios. O objetivo desse estudo foi analisar a atividade elétrica muscular de arqueiros durante o atirar uma flecha com o arco. Os participantes foram 10 arqueiros da Seleção Brasileira de Tiro com Arco. A eletromiografia captou a atividade elétrica muscular de 12 músculos. O acelerômetro no punho indicou o início do movimento. As fases temporais foram separadas entre 500 milissegundos pré e pós queda do clicker. O protocolo iniciou pela Contração Isométrica Voluntária Máxima dos músculos. Arqueiros lançaram 3 séries de 6 flechas no aquecimento. Arqueiros lançaram 12 séries de 6 flechas com intervalo de 20 minutos após a série 6. Análise de Variância One-way e o Tukey compararam as fases temporais. Análise de Variância One-way com medida repetidas comparou as fases temporais e os blocos de 6 flechas. Os resultados mostraram que todos os músculos (exceção do m. Multifido Lombar) aumentaram a demanda com a proximidade de soltura da flecha. Os músculos diminuem sua atividade pela redução da sua demanda na fase compensatória e de modulação. A comparação entre blocos de 6 flechas mostrou 3 formas do padrão temporal: 1) músculos afetados pelas fases e músculos afetado por todos/alguns fases nos blocos de 6 flechas, 2) músculos afetados pelas fases e músculos não afetados por todos/alguns fases nos blocos de 6 flechas e 3) músculos não afetados pelas fases e músculos afetados por todas as fases nos blocos de 6 flechas. Os músculos não afetados fases pelas fases/blocos mantem a atividade elétrica muscular ao longo dos intervalos pela sustentação da demanda muscular. Correlação cruzada entre os músculos motores mostrou que os músculos do antebraço obtiveram relação inversa entre eles. Outros músculos motores apresentaram alta correlação entre eles. Músculos posturais m. Multifido Lombar, m. Latíssimo do Dorso, m. Trapézio Superior apresentaram alta correlação com todos os músculos posturais. Músculos motores e posturais mostraram que m. Tríceps Braquial, m. Peitoral Maior Clavicular e m. Deltoide Posterior teve alta correlação com todos os músculos posturais. Em conclusão, a atividade elétrica muscular aumenta a demanda na fase antecipatória e diminui na após queda do clicker. Existem 3 caminhos na comparação das fases e os blocos de 6 flechas: afetado pela fase e 1) músculo afetado/2) músculo não afetado por todos/algumas fases nos blocos, 3) músculo não afetado pelas fases e afetado por todos as fases nos blocos. A correlação cruzada entre os músculos motores mostrou que os músculos do antebraço obteram relação inversa entre eles. Músculos posturais m. Multifido Lombar, m. Latissimo do Dorso, m. Trapézio Superior foram altamente correlacionados com todos músculos posturais. Músculos posturais e motores mostraram que m. Triceps Brachial, m. Petoral Maior Clavicular e m. Deltoide Posterior mostraram alta correlação com todos os músculos posturais

Page generated in 0.0306 seconds