• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 368
  • 4
  • 4
  • 4
  • 3
  • 3
  • 2
  • 1
  • Tagged with
  • 371
  • 371
  • 210
  • 149
  • 129
  • 101
  • 88
  • 84
  • 82
  • 66
  • 58
  • 53
  • 53
  • 47
  • 46
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Carta de zoneamento para seleção de áreas frente a instalação de aterros sanitários no município de São Carlos-SP, escala 1:50.000 / Favorable areas for waste sanitary landfills: 1:50,000 scale zoning chart of São Carlos region, SP, Brazil

Muro, Marcos Domingues 22 September 2000 (has links)
Sempre houve uma preocupação com relação a disposição final do lixo, tanto nas grandes como nas pequenas cidades. Este trabalho consiste em analisar áreas para uma disposição adequada de aterros sanitários no Município de São Carlos. O Município de São Carlos, localizado no Estado de São Paulo, apresenta uma área de 1.151 km2 e conta com uma população de aproximadamente 180.000 habitantes. Está assentado sobre as Formações geológicas: Pirambóia, Botucatu, Serra Geral, Itaqueri, que são recobertas por materiais inconsolidados retrabalhados; o Botucatu constitui um grande manancial de águas de subsuperfície. Algumas áreas devem ser protegidas, visto que constituem zonas de recarga de aqüíferos. A metodologia Leite (1995) foi usada neste trabalho para a escolha dos atributos e análise dos resultados. Os principais atributos considerados foram: bacias hidrográficas, declividade, poços profundos, precipitação pluviométrica, substrato rochoso, mineralogia, espessura de materiais inconsolidados, landforms, distâncias do centro urbano, existência de outros aterros; esses atributos foram associados às informações geotécnicas analisadas em laboratório. Estas informações, permitiram avaliar as áreas mais favoráveis para a disposição de resíduos e a produção da Carta de Zoneamento em escala 1:50.000. / The final disposal of waste has always been a matter of trouble in big or small urban centers. This work presents the results acquired during the application of engineering geological mapping techniques in the evaluation of favorable areas for the development of waste sanitary landfills in São Carlos region. São Carlos region is located in the center State of São Paulo, Brazil, has an area of 1,151 km2 and a population 180,000. It\'s geology is characterized by the Pirambóia, Botucatu, Serra Geral and Itaqueri formations, which are covered by residual and reworked unconsolidated materiais; Botucatu represent large aquifer. The methodology from LEITE (1995) was used in this work, both for choosing the attributes or analyzing the results. The main considered attributes were the drainage basins, slope dips, rainfall, underlying rocks, thickness of unconsolidated materials, landforms, distance from the urban center and the occurrence of other landfills; these attributes were associated to laboratorial test informations. These informations, as a whole, led to an evaluation of the most favorable areas for waste disposal and the elaboration of a 1:50,000 scale zoning chart.
102

Avaliação de áreas para disposição de resíduos: proposta de planilha para gerenciamento ambiental aplicado a aterro sanitário industrial / Site assessment for waste disposal: the proposition of a spreadsheet for environmental management applied to sanitary industrial landfills

Kataoka, Sergio Massaru 24 April 2000 (has links)
Esta dissertação apresenta uma revisão dos principais estudos relacionados à disposição final de resíduos sólidos das mais variadas origens em aterros sanitários ou aterros sanitários industriais. Considerando-se estes estudos, foi e laborada uma planilha para avaliação e gerenciamento ambiental de um aterro sanitário industrial, abordando os principais elementos necessários à caracterização do meio físico, biológico, sacio-econômico, além da avaliação dos critérios de projeto, classificação dos resíduos e programas de monitoramento e controle ambiental. As planilhas foram aplicadas na avaliação dos estudos de impacto ambiental EIA/relatório de impacto ambiental RIMA de 3 aterros sanitários industriais. O critério de avaliação foi baseado no atendimento aos itens da planilha adotando-se um sistema de pontuação para análise final dos estudos. A avaliação final mostrou as deficiências dos estudos apresentados nos EIA/RIMA elaborados para a obtenção do licenciamento ambiental e aprovação das áreas para instalação dos empreendimentos. / This dissertation presents a revision of the current researches on solid waste disposal, that comes from a great variety of domestic waste or industrial waste landfills. Concerning to this research, it was proposed a spreadsheet for environmental assessment and management of sanitary industrial landfills, comprising the most important features for the global environment, besides the evaluation of project criteria, waste classification, monitoring programs and environmental control. This spreadsheet have been applied to evaluate the environmental impact assessment (EIA) of three sanitary industrial landfills. The assessment criteria were based on ranking the elements that attend the spreadsheet items. As final results, it can be demonstrated the deficiencies of the current ElA studies that have been proposed for obtaining environmental licenses and permissions to sites for enterprising purposes.
103

Desempenho de camadas de proteção para geomembranas / Performance of protective layers for geomembranes

Geroto, Regis Eduardo 17 October 2008 (has links)
A eficiência das geomembranas como barreiras para controle e desvio de fluxo está diretamente relacionada com a integridade de sua superfície. Nos sistemas de impermeabilização basal, como utilizados em aterros sanitários, as geomembranas podem entrar em contato com materiais perfurantes e cortantes, como a brita do sistema de drenagem. Para prevenir perfurações e outros danos em geomembranas, são empregadas camadas de proteção, como geotêxteis não-tecidos e areia. Este estudo avalia o desempenho de geotêxteis não-tecidos de fibras curtas de poliéster (PET) e de polipropileno (PP), além de uma configuração com areia, como camadas de proteção para geomembranas de policloreto de vinila (PVC) e de polietileno de alta densidade (PEAD). Foram realizados ensaios índices, ensaios de puncionamento hidrostático e ensaios de carregamento estático em grande escala, para verificar os mecanismos de ruptura das geomembranas e o comportamento da resistência ao puncionamento com a adoção de camadas de proteção. Os resultados demonstraram desempenho superior, como elemento de proteção, dos geotêxteis de maior resistência mecânica e mecanismos de rupturas diferenciados entre geomembranas de PEAD e de PVC. / The efficiency of geomembranes as barriers for flow diversion is directly related to its integrity. In basal lining systems, such as those used in landfills and waste disposal lagoon, geomembranes can get into contact with sharp materials, such as gravel from the drainage system, which can induce excessive deformation and holes. To prevent geomembrane damage, nonwoven geotextiles and sand are usually employed as protective layers. This paper deals with the performance of polyester (PET) and polypropylene (PP) nonwoven geotextiles and a sand layer, as protective layers for polyvinyl chloride (PVC) and high density polyethylene (HDPE) geomembranes. Index, hydrostatic puncture and large-scale uniaxial compression tests were performed and have allowed understanding the geomembrane damage mechanism and the influence of protective layers properties in increasing the geomembrane performance against puncture. The test results have shown that the behavior in puncture protection is related to the mechanical resistance of geotextile and that the rupture mechanism is different for the different types of geomembrane used in the study.
104

Pós-tratamento de efluente de sistema biológico aeróbio em batelada de lixiviado de aterro sanitário através do processo físico-químico. / Post-treatment of waste water system in batch aerobic biological leachate from landfill through the physical-chemical process.

Silva, Rafael Camargo D\'Ambrósio da 22 September 2011 (has links)
As melhoras nas condições de disposição de resíduos sólidos em aterros sanitários teve, como conseqüência, a geração de um efluente com um grande potencial poluidor, o lixiviado de aterro sanitário, que anteriormente percolava pelo solo. Com o confinamento da massa de lixo e a impermeabilização do aterro, o lixiviado começou a ser coletado exigindo que o mesmo fosse tratado. A necessidade do tratamento deste efluente está relacionada com sua toxidade,pois contém altas concentrações de amônia, metais e alta carga orgânica que se originam da decomposição de compostos contidos no interior do aterro sanitário. Nesta pesquisa olixiviado é submetido a um pré-tratamento biológico com remoção de nitrogênio, no qual a maior parte da matéria orgânica, principalmente a facilmente biodegradável, é consumida,sobrando apenas compostos de cadeias longas de difícil biodegradabilidade e compostos inorgânicos, que são denominados compostos recalcitrantes, sendo em grande parte formados por substâncias húmicas. A intenção do trabalho foi maximizar a remoção destes compostos por meio de um tratamento físico-químico, realizado pelo processo de coagulação-floculação e é considerado uma forma complementar ao tratamento biológico. A pesquisa foi dividida em diversas etapas, em escala de bancada utilizando o jar teste, variando condições de pH de 2,0 a 5,0 e 10 a 12,0, com dosagens de coagulantes de 400mg Fe+³/l e polímeros aniônicos de alto peso molecular com dosagens de 0,5mg/l a 10,0 mg/l, a fim de encontrar a melhor condição de remoção dos compostos recalcitrantes, com o intuito de melhorar ao máximo as condições do efluente a fim de causar o menor impacto possível do mesmo ao ser lançado em cursos de água. De acordo com as variações na condição de tratamento do lixiviado, definiu-se que, com a diminuição do pH a 4,0 seguido de dosagens de 400mg Fe+³/l e ainda com a adição de 2,0 mg/l de polímero, foi possível atingir condições de remoção da ordem de 98% de cor e 80% de COT, indicando que a utilização de polímero é eficiente no processo de tratamento físico químico pelo processo de coagulação floculação de lixiviado de aterro sanitário / The improvements in the conditions of solid waste disposal in landfills has, as a consequence, the generation of an effluent polluted with great potential, landfill leachate, which previously percolated through the soil. With the containment of the waste stream and sealing of the landfill, the leachate began to be collected by requiring that it be treated. The need for treatment of wastewater is related to its toxicity, because it contains high concentrations of ammonia, metals and high organic load originating from the decomposition of compounds contained within the landfill. In this research the leachate is subjected to a pre- biological treatment with nitrogen removal, in which most of the organic matter, especially the readily biodegradable, is consumed, leaving only long-chain compounds difficult biodegradability and inorganic compounds, which are called recalcitrant compounds, being largely composed of humic substances. The intention of this study was to maximize the removal of these compounds by means of a physical-chemical treatment, performed by coagulation-flocculation process and is considered a complement to a biological treatment. The research was divided into several stages, using bench scale jar test conditions of pH ranging from 2.0 to 5.0 and 10 to 12.0, with dosages of coagulants Fe+³ 400 mg/l anionic polymers high molecular weight with dosages of 0.5 mg/l to 10.0 mg/l, in order to find the best condition for removal of recalcitrant compounds, with the most to improve the conditions of the effluent in order to cause minimum possible impact thereof to be released into waterways. According to the variations in the treatment condition of the leachate, it was decided that, with decreasing pH to 4.0 followed by doses of 400 mg Fe+³/l, even with the addition of 2.0 mg/l polymer conditions it was possible to achieve removal of about 98% color and 80% TOC, indicating that the use of polymer is effective in the physical-chemical treatment process by coagulation flocculation process for landfill leachate.
105

Utilização de métodos geoelétricos na caracterização de célula experimental no aterro de resíduos urbanos Delta A em Campinas - SP / Use of geoelectrical methods in the characterization of an experimental cell at the landfill of municipal waste Delta A in Campinas - SP.

Antonio Carlos de Siqueira Neto 20 March 2015 (has links)
Os métodos de eletrorresistividade (ER) com a técnica de caminhamento elétrico (CE), método da polarização induzida (IP) e o método eletromagnético indutivo (EM) foram aplicados no aterro Delta A, localizado ao lado da rodovia dos Bandeirantes no município de Campinas (SP). Dentro do aterro há uma região de aproximadamente 5.200 m² denominada célula experimental, com impermeabilização de base por meio de geomembrana de PEAD (Polietileno de alta densidade) onde ocorre um monitoramento regular pelo Departamento de Geotecnia da UNICAMP. Esse projeto teve como objetivo principal verificar como o corpo de resíduos e a geomembrana são imageados com os métodos geofísicos, e se existe evidência de zonas de concentração de chorume e como seriam as imagens caso houvesse ruptura da geomembrana com vazamento. Na área foram executadas 6 linhas com extensão de 110 m e espaçamento de 12 m entre elas, utilizando arranjo dipolo-dipolo com espaçamento entre eletrodos de 4 m e 5 m e cabo de 10 e 20 m para as medidas de EM. Com os resultados apresentados podemos afirmar que o método que melhor forneceu informações sobre a célula experimental foi o de eletrorresistividade, pois identificou a camada resistiva (geomembrana) e nos permitiu comparar os dados com as simulações feitas em laboratório. No entanto, para uma melhor resolução dos dados de ER se faz necessário diminuir a distância entre os eletrodos, aumentando assim a acurácia do levantamento. / The methods of resistivity (ER) with the electrical profiling technique (EP), the method of induced polarization (IP) and the inductive electromagnetic method (EM) were applied to landfill Delta A, located next to the highway dos Bandeirantes in Campinas (SP). Within the landfill there is a region of approximately 5,200 m² called \"experimental cell\" with waterproofing base through HDPE (High Density Polyethylene) geomembrane which is regular monitoring by the UNICAMP Geotechnical Department. The main objective was to verify how the body of waste and the geomembrane are imaged with geophysical methods, and if there is evidence of leachate concentration areas and how the images would be if there was rupture of the geomembrane leaking. In the area were performed 6 lines with a length of 110 m and 12 m spacing between them using dipole-dipole array with electrode spacing of 4 m and 5 m and cable of 10 and 20 m for EM measures. With the results presented we can say that the method that best provided information on the experimental cell was the resistivity method, as identified resistive layer (geomembrane) and allowed us to compare the data with simulations in the laboratory. However, for better resolution of the ER data is needed to close the distance between the electrodes, thereby increasing the accuracy of the survey.
106

Avaliação de impactos à saúde e ao meio ambiente provocados pelo mercúrio do amálgama odontológico nas Unidades Básicas de Saúde do município de Barra do Garças - MT / Assessment of impacts on health and the environment caused by mercury from dental amalgam in Basic Health Units of the city of Barra do Garças - MT.

Prampero, Ana Cristina Coelho Magrini 30 March 2012 (has links)
Made available in DSpace on 2016-08-10T10:53:31Z (GMT). No. of bitstreams: 1 ANA CRISTINA COELHO MAGRINI PRAMPERO.pdf: 18020182 bytes, checksum: 99118c08fcb346da81b1238fe9cba067 (MD5) Previous issue date: 2012-03-30 / The objective of this research paper was to evaluate the occupational exposure of the dental staff from the Basic Health Units from the city of Barra do Garças related to the contamination of mercury of dental amalgam. It was also evaluated the soil contamination of the city s sanitary landfill which is the possible place where the residuum of amalgam is disposed. In this study, it was identified the ways of packaging, handing and the mercury treatment and the amalgam by the dentists and auxiliaries from oral heath from the time they get to the dental office until the final disposal to the environment. At the sanitary landfill, we collected samples of the soil in the ditch septic transecta where the residuum from health service is dumped, from the ordinary ditch and the outside area from the sanitary landfill so as to compare the results. It was marked four points (north, south, east and west) around each ditch and the outer area and at every point sample was collected samples from the surface, 50cm deep and 1 meter deep totaling 36 samples. It was also carried out an interview at the 15 Basic Health Units from the city with a questionnaire with information about the habits, lifestyle and environmental characteristics and hair sample collection to find out the mercury levels from the dentists (n=15) auxiliaries of oral health (n=15) and a control group, in that case, the community health worker (n=15). The analyzes of the soil and the mercury content in hair were performed by the technique of atomic absorption spectrophotometer coupled to cold generator steam (CVAAS). The study concluded that there is no soil contamination from the landfill where the amalgam waste is disposed, and the results found are below the results found in the prevention and legislation related to the concentration of mercury content in the hair of both groups that were observed, and the results were below the tolerance values. As for the variables (length of service, alcohol consumption, smoking, fish consumption, vision and hearing problems and some neurological symptoms) there was no significant difference related to the concentration of mercury in the hair. Although there was no contamination of the dental staff, it is necessary to make the biological monitoring as it was observed failures during handing and the waste of the amalgam. It was also observed that the management regulations of the health solid waste were not fulfilled, indicating that the public service has to have and follow protocols according to the legislation. / O objetivo deste trabalho foi avaliar a exposição ocupacional da equipe odontológica das Unidades Básicas de Saúde do município de Barra do Garças quanto à contaminação pelo mercúrio do amálgama odontológico. Avaliou-se também a contaminação do solo do aterro sanitário municipal, local para onde possivelmente são descartados os resíduos de amálgama. Nesse estudo, foram identificadas as formas de acondicionamento, manuseio e tratamento do mercúrio e do amálgama pelos cirurgiões dentistas e auxiliares de saúde bucal do momento da chegada ao consultório odontológico até o descarte final no meio ambiente. No aterro sanitário foram coletadas amostras de solo em transecta da vala séptica, onde são depositados os resíduos de serviços de saúde, da vala comum e da área externa ao aterro para comparação dos resultados. Ao redor de cada vala e na área externa foram demarcados quatro pontos (norte, sul, leste e oeste) e em cada ponto foram coletadas amostras da superfície, 50 cm de profundidade e 1 metro de profundidade totalizando 36 amostras. Foi realizada também uma entrevista nas 15 Unidades Básicas de Saúde do município com a aplicação de questionário com informações a respeito dos hábitos, estilo de vida e características ambientais e coleta de amostras de cabelo para determinação dos teores de mercúrio dos dentistas (n=15), auxiliares de saúde bucal (n=15) e um grupo controle, no caso, o agente comunitário de saúde (n=15). As análises de solo e de teor de mercúrio no cabelo foram realizadas pela técnica de espectrofotometria de absorção atômica acoplada ao gerador de vapor frio (CVAAS). O estudo permitiu concluir que não há contaminação do solo do aterro sanitário onde são depositados os resíduos de amálgama, sendo que os valores encontrados estão abaixo dos valores de prevenção encontrados na legislação e que em relação à concentração de teor de mercúrio no cabelo dos grupos estudados, não foi verificado contaminação, estando os valores abaixo do valor de tolerância. Quanto às variáveis estudadas (tempo de serviço, consumo de bebida alcoólica, hábito de fumar, consumo de peixe, problemas de visão e audição e sintomas neurológicos) não houve diferença significativa em relação à concentração de mercúrio no cabelo. Mesmo não havendo contaminação da equipe odontológica deve-se fazer o monitoramento biológico, pois se verifica falhas durante o manuseio e descarte do amálgama. Foram observadas também falhas quanto ao cumprimento das normas de gerenciamento dos resíduos sólidos de saúde, denotando a necessidade do serviço público em ter e seguir protocolos conforme a legislação.
107

Geração de energia a partir de resíduos sólidos urbanos: avaliação e diretrizes para tecnologias potencialmente aplicáveis no Brasil / Power Generation From Solid Waste: Assessment and Guidelines for Potentially Applicable Technologies in Brazil

Pavan, Margareth de Cassia Oliveira 19 November 2010 (has links)
O gerenciamento de resíduos sólidos urbanos (RSU) tornou-se uma tarefa que demanda ações diferenciadas e articuladas, em função da quantidade e diversidade dos mesmos. O grande desafio está em encontrar soluções ambientalmente seguras, socialmente adequadas e economicamente eficientes para equacionar este problema. Todavia, se corretamente gerenciados, estes resíduos podem ser aproveitados do ponto de vista energético. Estimativas realizadas neste estudo apontam para um potencial de geração de energia a partir de resíduos urbanos, para o Brasil, da ordem de 16 GW (utilizando o processo de incineração) ou 5,8 GW (pela digestão anaeróbia em aterros). Outros benefícios da recuperação energética dos resíduos também podem ser destacados tais como: (a) benefícios estratégicos, uma vez que essa ação pode contribuir como fonte alternativa de energia; (b) benefícios ambientais, pois colabora com organização dos aterros e a mitigação de gases de efeito estufa; (c) benefícios sócio-econômicos, devido ao desenvolvimento de tecnologia nacional com o uso de equipamento e insumos nacionais e, sobretudo, (d) emprego de mão-de-obra qualificada e não qualificada nas várias etapas do processo de recuperação energética. O presente trabalho faz uma análise das tecnologias potencialmente aplicáveis no Brasil, para recuperação energética a partir RSU, e propõe uma série de diretrizes para esse aproveitamento, levando em consideração as especificidades da realidade brasileira. / The management of solid waste (MSW) has become a challenge that demands articulated and non-conventional actions because of the quantity and diversity of such wastes. Finding environmentally friendly, socially adequate and economically efficient solutions to overcome this issue is the challenge to be faced. Nevertheless, if properly managed, these wastes can be recovered from the standpoint of energy. Estimates presented in this work highlight a potential power generation from urban waste, in Brazil, around 16 GW (using incineration process) or 5.8 GW (by anaerobic digestion in landfills). Several other advantages of recovering energy from waste could also be rolled as follows: (a) strategic benefits, since it may contribute as an alternative energy source and increase energy supply; (b) environmental benefits, once it contributes to improve waste management and to the mitigation of greenhouse gases; (c) social-economic benefits, due to the development of a Brazilian technology taking advantage of national equipment and materials, and most important, (d) employment of skilled and unskilled labor in the various stages of the energy recovery process. This thesis analyzes though the technologies potentially applicable in Brazil for energy recovery from MSW, and proposes guidelines for such use taking into account the specificities of the Brazilian reality.
108

Estudo da utilização da energia do biogás na incineração do chorume em aterros sanitários: eliminação simultânea de duas fontes poluentes - gasosa e líquida / not available

Regattieri, Carlos Roberto 08 December 2003 (has links)
Este trabalho foi realizado junto ao NETeF - Núcleo de Engenharia Térmica e Fluídos da EESC/USP e ao aterro sanitário \"Fazenda Guaporé\" em São Carlos, e teve como objetivo a verificação da viabilidade energética e ambiental do tratamento do chorume através da sua incineração com o biogás produzido pelo aterro, eliminando-se desta forma também o metano, reconhecido como gás estufa. Determinou-se experimentalmente a composição do biogás e calculou-se e mediu-se a sua vazão. As propriedades físico-químicas e a vazão do chorume também foram quantificadas. A vazão de gás foi calculada com informações obtidas da literatura e medida experimentalmente com uma sonda especialmente desenvolvida neste trabalho. Para determinar a aplicabilidade do conceito fez-se um balanço energético para verificar a disponibilidade de energia e um balanço químico, para determinar o potencial de emissão de poluentes do ar. Os resultados indicaram que há mais energia presente no gás do que a energia requerida para incinerar o chorume, embora a diferença seja pequena e deva ser vista com cautela. O balanço químico mostrou em geral um potencial poluidor abaixo das emissões permitidas pela legislação, embora em alguns casos isto não tenha ocorrido. / This work was developed at the NETeF (Thermal Engineering and Fluids Group) at EESC/USP, Sao Carlos, SP, and the local landfill \"Guapore Farm\". It was aimed to the treatment of the \"chorume\" through its incineration with the biogas produced in the landfill, this way eliminating also the methane, the second most important greenhouse gas according to IPCC. The composition and flow rate of the biogas were determined by calculations and experimentaly and the same was done with the chorume. The gas flowrate was calculated using data available in the literature and measured with a probe specially developed in this work. To evaluate the feasibility of the concept it was done a balance of energy to verify if the energy of the gas was enough to the chorume thermal destruction and a chemical balance to determinate the potential of emission of air pollutants. The results have shown that there is more energy available than it is required for that purpose but they should be considered with some caution given the small diference between the required and produced energy and the uncertaints in the measurements and evaluations. The chemical balance has shown that, in general, the potential for emissions was bellow the legally stablished limits although in a few cases it was above.
109

Utilização de biogás de aterro sanitário para geração de energia elétrica - estudo de caso / Use of landfill biogas for electric energy production Case study

Figueiredo, Natalie Jimenez Verdi de 27 May 2011 (has links)
A intensificação das atividades humanas nas últimas décadas tem gerado um acelerado aumento na produção de resíduos sólidos urbanos (lixo), tornando-se um grave problema para as administrações públicas e para a sociedade. O aumento desordenado da população e o crescimento sem planejamento de grandes núcleos urbanos dificultam as ações de manejo dos resíduos; além disso, o uso de lixões nos grandes centros urbanos ainda é uma prática comum, o que gera problemas de saúde e ambientais. A decomposição da matéria orgânica promove a liberação do biogás, cujos principais constituintes são o gás carbônico e o metano, que corresponde a cerca de 50% e é um gás de efeito estufa, cuja emissão acarreta no aquecimento global. Além disso, gera odores desagradáveis e oferece riscos de explosão. Os aterros sanitários são considerados atualmente uma alternativa das mais interessantes para geração do biogás, visto que podem dispor de técnicas de captação dos gases liberados através de dutos de captação e queima posterior em flares, onde o metano, principal constituinte do biogás é transformado em gás carbônico, que possui um potencial de aquecimento global cerca de 20 vezes menor que o metano. Nestes aterros também existem dutos para captação do chorume, líquido proveniente da decomposição de resíduos orgânicos que se não for devidamente coletado, acarreta poluição dos recursos hídricos. Além da oportunidade de reduzir os danos ambientais é possível utilizar o biogás como combustível, gerando energia elétrica. Portanto, neste estudo é avaliado o potencial de geração de biogás do Aterro Essencis CTR Caieiras, na cidade de Caieiras, SP, e a viabilidade técnica e econômica da implantação de um projeto de geração de energia elétrica com o biogás proveniente do mesmo, por meio de um estudo de caso. Este estudo mostrou que a metodologia utilizada para quantificar o potencial de biogás do aterro em questão aproxima-se do real captado e também que a CTR Caieiras possui um alto potencial de geração de energia elétrica. Além disto, o grupo motogerador de 230 kW instalado no aterro é viável do ponto de vista econômico, podendo apresentar melhores resultados com a instalação de grupos motogeradores de maior porte. / The intensification of human activities in the last few decades has brought about an accelerated increase in the production of urban solid wastes (garbage), becoming a serious problem for the public administrations and society. The disorderly increase in population and the unplanned growth of huge urban nuclei makes it difficult for the waste management actions; in addition, the use of dump areas in the major urban centers is still a common practice, what causes health and environmental problems. The decomposition of the organic matter releases biogas, which main constituents are the carbonic gas and methane, corresponding to approximately 50% and is a greenhouse gas, which emission causes global heating. In addition, it generates unpleasant odors and presents explosion risks. The sanitary landfills are currently regarded as one of the most interesting alternatives for biogas generation, as they can rely on techniques to capture the gases released, through a capturing ducts and subsequent burning in flares, where the methane - biogas main constituent - is transformed into carbonic gas which global heating potential is approximately 20 times lower than methane. Ducts are in place at these landfills to capture the leachate, a liquid deriving from the decomposition of organic wastes which, if not duly collected, pollutes the hydrological resources. Besides the opportunity to reduce the environmental damages, it is possible to use biogas as a fuel to generate electric power. Therefore, this study assesses the potential biogas generation of the Essencis Landfill CTR Caieiras, in the city of Caieiras (SP), as well as the technical and economic feasibility for the deployment of an electric power generation project with the biogas deriving from same, by means of a case study. This study has showed that the methodology used in order to quantify the potential biogas from the landfill at issue is close to the actually captured one, and also that the CTR Caieiras has a high potential for electric power generation. In addition, the 230 kW power generator installed at the landfill is feasible, from the economic point of view, and may present better results with the installation of greater size power generators.
110

Caracterização dos líquidos percolados gerados por disposição de lixo urbano em diferentes sistemas de aterramento / Characterization of leachate originated from final disposal of municipal landfill produced by different system of disposal

Paschoalato, Cristina Filomena Pereira Rosa 07 April 2000 (has links)
O trabalho tem como finalidade a realização de um estudo a respeito da análise de parâmetros analíticos, determinados em líquidos percolados provenientes de disposição final de lixo urbano gerados por diferentes sistemas de aterramento. O estudo foi realizado no município de Ribeirão Preto, analisando-se 45 parâmetros em amostras de líquidos percolados de aterros sanitários, distintos entre si nos seguintes aspectos: geológico, cronológico e operacional. A partir dos resultados obtidos, pretende-se verificar os parâmetros analisados nos diferentes líquidos percolados, procurando-se compará-los entre si, para verificação de possível influência do tipo de aterramento em relação a essas variáveis. O trabalho objetiva ainda, o desenvolvimento e adaptações de técnicas referentes às metodologias para a determinação dos parâmetros, visando a eliminação de interferentes das amostras complexas, como é o caso dos líquidos percolados e chorume. Os resultados foram obtidos através de ensaios realizados no Laboratório de Recursos Hídricos da Universidade de Ribeirão Preto - UNAERP. / This work is aimed on a study about the analysis of a analytical parameters determinate on leachate from final disposition of municipal landfill produced by different systems of disposal. The study took place in the town of Ribeirão Preto, analyzing forty five parameters in samples of leachate from landfill area, distinct among themselves in aspects such as geological, chronological and operational. From given results it is intended to check the parameters analyzed in different leachate comparing themselves, for checking possible influence from the kind of landfill area according to the aspect above. It techniques referent the methodology to determinate the parameters, trying to put interference of matrix samples such is the leachates. The results were achieved through studies do realizable the hydric sources laboratory at the University of Ribeirão Preto - UNAERP.

Page generated in 0.0888 seconds