• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 499
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 1
  • 1
  • 1
  • Tagged with
  • 507
  • 374
  • 258
  • 188
  • 162
  • 115
  • 110
  • 102
  • 101
  • 95
  • 92
  • 66
  • 59
  • 58
  • 55
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
361

Avaliação da biodegradabilidade de lixiviado de aterro sanitário consorciado com esgoto doméstico em um sistema biológico de tratamento de efluentes

Reque, Patrícia Tambosi January 2015 (has links)
O líquido denominado “lixiviado”, formado pela disposição de resíduos em aterros sanitários e lixões, apresenta composição complexa, dada principalmente pela presença de compostos orgânicos extremamente recalcitrantes. O tratamento consorciado deste efluente com esgotos domésticos em ETE’s municipais carece de estudos, tendo em vista que são líquidos com características diferentes. Neste trabalho foi avaliado o desempenho de um processo biológico de tratamento de efluentes, composto por 3 sistemas de banhados construídos (B1, B2 e B3) operados em paralelo, tratando a combinação de esgoto doméstico (90%) + lixiviado de aterro sanitário (10%), no que diz respeito a remoção de matéria orgânica de lenta degradação. Cada sistema foi composto por 4 leitos cultivados com as macrófitas emergentes Luziola peruviana e Typha latifolia, recebendo afluente proveniente de diferentes níveis de pré-tratamento, nomeadamente: B1 - processo biológico anaeróbio (UASB) seguido de aeróbio (CBR); B2 - processo biológico aneróbio (UASB) e B3 - sem prévio tratamento. Para tal, além das análises da matéria orgânica pelos parâmetros não específicos, foi também empregada análise de absorbância e fluorescência para analisar a presença de substâncias húmicas e o uso da respirometria para avaliação da DQO lentamente biodegradável. As eficiências médias de remoção dos sistemas B1, B2 e B3 foi de 97,4, 96,1 e 96,6 % para DBO5, 66,9, 70,9 e 80,6% para DQOT, 61,9, 69 e 62,8 % para DQOFil e de 60,3, 72,8 e 72 % para COT, respectivamente. A avaliação destes parâmetros permitiu inferir que o nível de pré-tratamento não influenciou na eficiência de remoção pelos sistemas de banhados. Os espectros de absorbância foram marcados por maior absorbância na região λ < 400 nm, com diminuição progressiva até 700 nm. A aplicação de coeficientes de absortividade indicaram a predominância de matéria orgânica dissolvida proveniente de esgoto doméstico, com pouca influência de SH’s. Nos espectros de emissão de fluorescência, o aparecimento de bandas na região de 450 nm indicou a presença de substâncias húmicas no afluente e efluente do sistema de banhados construídos, sem diferença significativa entre a intensidade de fluorescência emitida em 450 nm nas amostras analisadas, indicando que a substância em questão passou pelo tratamento sem ser degradada. Os resultados observados pela análise de fluorescência sincronizada do B1 apresentaram contribuição positiva do pré-tratamento (menor concentração de DQOFil) para o desempenho do banhado, devido a menor presença de ácidos húmicos no efluente. / The liquid known as "leachate", produced by the disposal of waste in landfills and dumps, has a complex composition, characterized mainly by the presence of recalcitrant organic compounds. Currently, there is a lack of knowledge regarding the co-treatment of leachate with municipal wastewater in WWTP's, considering that these are effluents with different characteristics. This study evaluated the performance of a biological treatment process of wastewater consisting of 3 constructed wetlands systems (B1, B2 and B3), operated in parallel, treating a combination of domestic sewage (90%) + landfill leachate (10 %). Each system was comprised of four beds cultured with emerging macrophytes Luziola peruviana and Typha latifolia receiving affluent from different levels of pre-treatment, namely: B1 - anaerobic biological process (UASB) followed by aerobic biological process (CBR); B2 - anaerobic biological process (UASB). B3 received the untreated effluents. The content of organic matter and humic substances was analyzed by non-specific parameters, absorbance and fluorescence methods. Respirometry test were conducted to evaluate the content of slowly biodegradable COD. The average removal efficiencies of systems B1, B2 and B3 was of 97.4, 96.1 and 96.6% for BOD5, 66.9, 70.9 and 80.6% for CODT, 61,9, 69 and 62.8% for CODFil and 60.3, 72.8 and 72% of TOC, respectively. The evaluation of these parameters allowed to infer that the level of pre-treatment did not influenced the removal efficiency by wetland systems. Absorbance spectra were marked by greater absorbance in the region λ = <400 nm with progressive decrease up to 700 nm. Absorptivity coefficients indicated the predominance of domestic sewage, with little influence of SH's. In the fluorescence emission spectra, the appearance of bands in the 450 nm region indicated the presence of humic substances in the influent and effluent of the constructed wetland systems without a significant. This indicates that the substance in question went through the treatment without being degraded. The results obtained by synchronous fluorescence analysis showed a positive contribution of the B1 pretreatment (lowest concentration DQOFil) to the observed performance due to less presence of humic acids in the effluent. The authors did not have success during evaluation of the slowly biodegradable COD using the method proposed before.
362

Resíduos sólidos urbanos : uma proposta para otimização dos serviços de coleta e da disposição final / Urban solid residues: a proposal to optimize the collection services and the final disposal

Bridi, Eliana January 2008 (has links)
O município de Porto Alegre possui uma única estação de transbordo localizada no bairro Lomba do Pinheiro (Zona Leste) que recebe todo o resíduo sólido urbano (RSU) coletado, que tem como destino final o aterro sanitário localizado em Minas do Leão/RS. Uma parte deste material é triado, com separação de materiais recicláveis que são vendidos às indústrias de reciclagem através de unidades de triagem conveniadas à prefeitura local e material orgânico, que através do processo de compostagem é transformado em composto e comercializado. Foi feito um levantamento de dados relativos aos RSU como: volumes de coleta, quilometragem percorrida pelos caminhões de coleta, custo de equipamentos e áreas disponíveis no município. Após a análise destes dados, constatou-se a possibilidade de otimizar o serviço de coleta e de disposição final. Esta otimização pretende reduzir tanto os impactos ambientais gerados por estas atividades, bem como os custos decorrentes. A criação de uma segunda estação de transbordo, proposta para a área do já enclausurado aterro da Zona Norte, foi a opção que melhor atendeu aos critérios estabelecidos. A nova estação de transbordo apresenta vantagens relacionadas à adoção de novas tecnologias, à economia e a preservação ambiental. A área escolhida para o novo transbordo levou em conta aspectos como: centralidade, área útil disponível e provável facilidade no licenciamento ambiental. Na concepção do novo transbordo sugere-se a instalação de equipamentos compactadores, bem como medidas para maximizar a triagem de resíduos e o conseqüente diminuição de materiais destinados ao aterro sanitário, com conseqüente economia no transporte e aumento da vida útil do aterro. Para a estação de transbordo atual, na Lomba do Pinheiro, sugere-se um aumento na triagem de resíduos e o conseqüente aumento na produção do composto. Estas providências reduzem significativamente a massa de resíduos que diariamente é destinada ao aterro em Minas do Leão. / The city of Porto Alegre has a single transshipment station located in the district of Lomba do Pinheiro (East) that receives all the colleted municipal solid waste (MSW) , which has as final destination the sanitary landfill located in nearby city of Minas do Leão / RS. Part of this waste is separated and the recyclable materials are sold to local recycling industries of recycling through units of selection that have signed agreements with the city authorities. The organic waste goes through the process o composting and then sold. A survey was done on MSW looking at: volumes of collection, milage of the collecting trucks, the cost of equipment and available areas in the county. After analysis of these data, there was the possibility to optimize the service of collection and final disposal. This optimization reduces both the environmental impacts generated by these activities as well as the costs involved. The creation of a second transhipment station in the Northern District sanitary landfill area was the option that best met the established criteria. This new transhipment station has advantages related to the adoption of new technologies, the economy and environmental preservation. The area chosen for the new transshipment station took into account aspects such as: central location, available usefull area and easy environmental licensing. The concept of a new transhipment station suggests the installation of compacting equipments as well as actions to maximize the sorting of waste and the consequent reduction of materials destinated to the landfill with consequent economy in transport and increasing the useful life of the landfill. To the Lomba Pinheiro transshipment station it is suggested an increase in the sorting of waste and the consequent increase in the production of compost. These procedures significantly reduce the mass of daily waste that is destinated to the landfill in Minas do Leão.
363

Metrópole de Risco : o caso da Vila Dique e do aterro sanitário da zona norte na poluição das águas superficiais e subterrâneas das bacias hidrográficas do Arroio da Areia e Passo das Pedras/Porto Alegre-RS

Troleis, Adriano Lima January 2009 (has links)
O presente estudo investigou a influência da vila Dique o do Aterro Sanitário da Zona Norte, na qualidade das águas superficiais e subterrâneas, das bacias hidrográficas do arroio da Areia e Passo das Pedras, no município de Porto Alegre, Rio Grande do Sul, Brasil. A metodologia deste estudo envolveu duas estratégias de abordagem: teórico-conceitual e operacional. A teórica orientou-se pelos eixos de abordagem: qualidade das águas; processo de urbanização mundial, brasileiro e da cidade de Porto Alegre; problemas ambientais, espaço urbano; legislação e instrumentos de políticas públicas; e caracterização da área de estudo. Do ponto de vista operacional, foram analisados dados mensais de qualidade das águas superficiais, subterrâneas e do líquido percolado de parâmetros químicos, bacteriológicos e metais pesados coletados pelo Departamento Municipal de Limpeza Urbana, do período de 1991 a 2008. Os resultados revelaram uma grande contribuição da malha urbana, na concentração de poluentes de origem orgânica no arroio da Areia, principalmente no segmento da vila Dique, visto que a mesma não apresenta saneamento básico. O monitoramento nas células e no entorno do aterro apresentou, tanto nos pontos de água superficial quanto nos poços de água subterrânea e do líquido percolado, elevados índices de poluição, evidenciando uma ineficácia no sistema de controle de suas lixívias. A etapa final dessa análise resultou na elaboração da cartografia de qualidade das águas, cujo objetivo foi proporcionar uma série de dados espacializados, úteis à realização da classificação das águas, quanto ao grau de poluição, utilizando, para isso, as Resoluções n° 357/2005 e 396/2008, do Conselho Nacional do Meio Ambiente e Resolução n° 128/2006 do Conselho Estadual de Meio Ambiente. Realizou-se, também, um monitoramento geofísico, dentro dos limites do aterro e nas suas áreas adjacentes, com o objetivo de identificar as alterações nos corpos de água subterrânea, em função das lixívias produzidas pelo aterro. Foram elaborados mapas de condutividade elétrica do aterro e de suas áreas adjacentes, em três profundidades 7,5, 15 e 30m, que permitiram identificar a presença e mapear o fluxo da pluma, destacando seus principais pontos de poluição, revelados pelos elevados picos de condutividade. Em síntese, a vila Dique apresentou, no que diz respeito à ocupação, as seguintes irregularidades, que contrariam o planejamento urbanístico: o acesso às redes de água e energia elétrica é feito, quase exclusivamente, através de ligações clandestinas; não possui uma rede de esgoto; e muitas unidades habitacionais sofrem frequentes inundações. Já a área onde se situa o ASZN também apresenta irregularidades, quanto ao uso da terra. Essas contrariam as legislações ambientais atuais, no que se refere a poluição dos recursos hídricos e à deposição e ao gerenciamento dos resíduos sólidos. A área de estudo, portanto, é classificada como de risco, pois apresenta forte presença de poluição, em virtude da vila Dique não possuir saneamento básico e do aterro sanitário não apresentar um sistema de lixívias controlado. Conclui-se que é necessária a remoção da vila e o contínuo monitoramento das águas, por 20 anos, tempo necessário para a estabilização da matéria orgânica ali depositada. / This study investigated the influence of the Dique shantytown and the Northern Landfill on the quality of surface and underground waters of the Areia and Passo das Pedras water stream basins, in Porto Alegre, Rio Grande do Sul, Brazil. Its methodology involved two approaching strategies: a theoretical-conceptual one and an operational one. The former was based on the following axis: water quality; urbanization process in the world, in Brazil, and in Porto Alegre; environmental problems, urban space; legislation and public policy tools; and characterization of the area under study. From the operational point of view, monthly data on the quality of surface and underground water were examined as well as that of percolated liquid by chemical and bacteriological parameters as well as heavy metals, collected by the Urban Cleaning Municipal Department from 1991 to 2008. The results revealed a major contribution of the urban network to the concentration of organic pollution agents in the Areia stream, specially its segment at the Dique shantytown, since it has no basic sanitation. Monitoring on cells and the area around the landfill presented - both in surface water points and in underground water wells and percolated liquid - high pollution levels, showing the ineffectiveness of the system of control of leach. The final stage in the analysis resulted in the cartography of water quality, whose aim was to provide a series of space-based data useful to classify waters according to their pollution level by using Resolutions 357/2005 and 396/2008 of the National Environmental Council and Resolution 128/2006 of the State Environmental Council. Geophysical monitoring has also been conducted within the limits of the landfill and its adjacent areas in order to identify changes in underground water bodies because of leach generated by the landfill. Maps were made on the landfill's electrical conductivity and its adjacent areas at three depth levels: 7.5 m, 15 m, and 30 m, which allowed to identify the presence and map the plume flow, showing its main pollution points revealed by high conductivity peaks. In sum, regarding occupation, the Dique shantytown presented the following irregularities, which violate urban planning: water and electricity networks are accessed almost exclusively by clandestine connections; there is no sewerage network; several housing units suffer frequent floods. The area where the landfill is located, in turn, also presents irregularities regarding land use. They violate today's environmental legislation in terms of pollution of water resources and deposition and management of solid residues. Therefore, the area under study is classified as an area of risk for its high pollution because the Dique shantytown has no basic sanitation and the landfill does not have a leach control system. It is found that removal of the shantytown and permanent monitoring of waters for 20 years are necessary - until organic matter deposit in the place stabilizes.
364

Análise de aproveitamento energético em aterros sanitários baseada em cenários de produção de efluentes

Thomazoni, André Luis Ribeiro January 2014 (has links)
O aumento da preocupação de soluções ambientalmente adequadas e energeticamente eficientes, aliado às recentes mudanças nas diretrizes políticas Brasileiras em relação à gestão e ao gerenciamento de resíduos sólidos e suas práticas de disposição final, permite a oportunidade de investigar a recuperação energética e o abatimento dos efluentes gerados por aterros sanitários. O presente trabalho explora, separadamente, o uso de modelo de previsão de produção de biogás baseado no decaimento de primeira ordem, e para a estimativa de produção de lixiviado, aplica-se o método do balanço hídrico (MBH). A partir de variação dos principais parâmetros de entrada de cada modelo, obtêm-se cenários de produção de biogás e estimativas da capacidade de geração máxima e mínima de lixiviado para o aterro sanitário de Guajuviras (Canoas - RS, Brasil). Tomando os resultados de geração de lixiviado e de biogás calculados, estima-se o potencial energético disponível e o desempenho de três diferentes sistemas de conversão energética propostos: geração elétrica por motogeradores, evaporação de lixiviado em regime de cogeração com motogeradores, motogeradores com trocadores de calor em regime de cogeração e sistema de evaporação de lixiviado (LES). Resultados obtidos para o período analisado, mostram que a produção elétrica do cenário mais conservador está na faixa entre 17.300 a 18.800 MWh, enquanto que a produção de energia elétrica do cenário otimista atinge valores entre 416.976 e 459.900 MWh. Já para a evaporação de lixiviado, os volumes evaporados em regime de cogeração variaram de 1 a 70% em relação ao volume de lixiviado gerado pelo aterro sanitário, enquanto que o LES, considerando o cenário otimista, foi capaz de evaporar 100% do lixiviado durante 18 anos. / The growing concern on environmentally suitable and energy efficient solutions allied with the recent changes in the Brazilian policies on the solid waste management and its final disposal practices, enables an opportunity to investigate the energy recovery and abatement of landfills emissions. The present work explores separately the utilization of 1st order decay model for assess the landfill gas (LFG) production, and applies the water budget method for prediction of leachate generation. Ranging the main input parameters on each model, were obtained distinct scenarios for LFG production and the maximum and minimum leachate generation capacity of Guajuviras landfill (Canoas- RS, Brazil). Based in the calculated results for leachate and LFG production were assessed the available energetic potential and the performance of three distinct energetic conversion systems: motogenerators, heat exchangers in cogeneration with motogenerators and leachate evaporation system (LES). Results for the analyzed period show that the electric generation for conservative scenario ranges between 17.300 to 18.800 MWh, whereas, the electricity production for more optimistic scenario ranges between 416.976 to 459.900 MWh. As for the leachate evaporation, the evaporated volume by the cogeneration system reaches values between 1 to 70% of the leachate produced by the landfill, whereas, the LES, considering the optimistic scenario, is able to evaporate all the generated leachate by the landfill among 18 years.
365

Análise da potencialidade de alguns solos não lateríticos para utilização em barreiras impermeáveis / Analysis of the potential use of non lateritic soils in hydraulic barriers

Célio Roberto Campos Piedade Junior 18 March 2003 (has links)
Apresenta-se uma avaliação do potencial de alguns solos não lateríticos, compactados, para uso como barreira impermeável, com bases em suas condutividades hidráulicas e contrações axiais. Dez tipos diferentes de solos foram analisados, sendo seis classificados como Não Laterítico Argiloso (NG\') e quatro como Não Laterítico Siltoso (NS\') de acordo com o sistema de classificação MCT. Nas análises foi verificada a influência de parâmetros de compactação e de algumas propriedades dos solos na condutividade hidráulica e na contração axial dos solos compactados. Verificou-se que, para a maioria dos solos houve a diminuição da condutividade hidráulica com o aumento da energia de compactação. Com relação à umidade de moldagem, os menores valores de condutividade hidráulica estiveram associados a umidades iguais ou acima da ótima. Alguns solos não tiveram a condutividade hidráulica influenciados pelo teor de umidade, talvez como reflexo de suas características de compactação, pois mostraram massa específica constante com a umidade, para uma dada energia de compactação. Constatou-se que a condutividade hidráulica diminui com o aumento do índice de plasticidade, da umidade volumétrica e com os resultados do ensaio de absorção de azul de metileno. Para a contração axial nota-se que ela foi pouco influenciado pelo aumento do teor de umidade e pela energia de compactação, estando os maiores valores associados às menores condutividades hidráulicas. Constatou-se que a contração aumenta com o aumento da porcentagem de argila, do índice de plasticidade, dos resultados do ensaio de azul de metileno e com a diminuição do limite de contração. / It is presented an evaluation of the potential of certain non-lateric soils, compacted, for lining system use, based on their hydraulic conductivity and axial shrinkages. Ten different types of soils were analyzed; six of them were classified as non-lateric clayey (NG\') and the other four as non-lateric silty (NS\'), according to the classification system MCT. It was verified the influence of parameters of compaction and some soil properties on the hydraulic conductivity and on the axial shrinkage of compacted soils. Results of the analysis indicate that, for the most of the soils there were decrease of hydraulic conductivity when increasing the energy of compaction. In relation to the molding water content, the lower values of hydraulic conductivity were associated to equal to or over optimum water content. Some soils did not have their hydraulic conductivity influenced by the water content, perhaps as a result of their compaction characteristics, since they showed constant specific mass with the humidity, for a given energy of compaction. It was verified that the hydraulic conductivity decreases as plasticity index and volumetric humidity increases, with the result of the adsorption of metilen blue. The axial shrinkage was very little influenced by the increase of the water content and by the energy of compaction, the greater values associated to lower hydraulic conductivity. It was verified that the contraction increases with the increases of clay content, plasticity index, results of metilen blue test and the decrease of the contraction limit.
366

O meio físico no processo de avaliação de impacto ambiental do aterro industrial Brunelli - Piracicaba (SP) / The physical environment on the environmental impact assessment of the Brunelli industrial landfill project, Piracicaba, State of São Paulo, Brazil

Marcos Antonio Mattiusso Marques 20 March 2000 (has links)
Neste trabalho, é analisado o processo de avaliação de impacto ambiental - AIA do Aterro Industrial Brunelli, que se caracterizou como bastante complexo, em razão da polêmica em torno dos impactos ambientais incidentes em sua área de influência, principalmente os relativos à contaminação do solo e da água. São descritos os principais elementos do projeto e as características dos entornos da área selecionada para a implantação do aterro, bem como analisados os principais fatores que fundamentaram a decisão da Secretaria do Meio Ambiente pela viabilidade ambiental do empreendimento. São apresentadas, ainda, avaliações de outras instituições que contribuíram, com seus pareceres técnicos, no processo de tomada de decisão. A partir dessa análise, é apresentada uma avaliação crítica dos principais fatores que resultaram na morosidade do licenciamento e propostos critérios para o aperfeiçoamento dos processos de AIA de unidades de disposição de resíduos. / This work is focused on the environmental impact assessment of the Brunelli Industrial Landfill Project, which proved to be a very complex process, mainly because of the expected environmental impact in the neighborhood of the plant, especially those related to soil and water contamination. The project major elements are presented, as well as the basic characteristics of the selected area for landfill development, besides a complete analysis of the principal facts that supported the São Paulo State Secretariat of the Environment final decision on the matter. Several technical contributions by a number of other Institutions are also presented, regarding the environmental viability of the project, which were very important in the decision making process. A critical review and analysis of all the information allowed identifying the factors that were responsible for the delay in final decision taken by the State Secretariat. As a consequence, some proposals are made in order to improve the assessment of environmental impacts of similar facilities.
367

A história da devastação dos manguezais aracajuanos

Almeida, Fernanda Cordeiro de 18 February 2008 (has links)
This dissertation aims at understanding, based on Aracaju city history, the reasons why the mangroves of the city were covered with earth. To answer this question, it was necessary to state three more specific objectives: to indentify the reasons for mangroves covering throughout Aracaju history; to locate the areas where there used to be mangroves, but not anymore; and to show the relationship between the aracajuano inhabitant and the mangroves. After the first step of the research, the data collection, the research documents were categorized, according to Bardin (1977). In the first specific objective there are the categories named public sphere and the public-private connection, divided into another classes: health, accessibility, housing and real estate speculation; the last two objectives can be observed throughout the analysis. The historical sources studied, like the reports given by the presidents of Sergipe province in the 19th century, point out the covering as a constant routine. Together with this findings, the observation of the recent urbanization, mainly in Jardins area (1996-1997) and the occupation on the mangroves are the reason for the first time delimitation from 1855 to 2005. Although the 150 year-celebration could stop the analyzes about the theme and induce to the total history, that is not the purpose. From this research, the reasons for the coverings show a continuous time and, besides that, an agreement by civil society in which the government is included. Finally, this study, while historical study of the devastation and partial extinction of Aracaju mangroves, does not intend to judge the man from the past, but to alert to its probable extinction. / Esta dissertação tem o intuito de compreender, através da trajetória histórica de Aracaju, por que motivos os manguezais da cidade foram aterrados. Para atingi-lo, foi necessária a elaboração de mais três objetivos específicos, que foram: identificar as motivações para os aterramentos de manguezais ao longo da História de Aracaju; localizar as áreas abrangidas por manguezais, na cidade de Aracaju, no passado, e compara-las às do presente; demonstrar a relação aracajuano-manguezal presente na documentação pesquisada. Após o primeiro passo da pesquisa, que foi a coleta de fontes, o conjunto da documentação pesquisado foi categorizado, de acordo com a análise de conteúdo sugerida por Bardin (1977). No primeiro objetivo específico, encontraram-se as categorias esfera pública e a conexão público-privada, divididas nas subcategorias: salubridade, acessibilidade, habitação e especulação imobiliária. Os dois últimos objetivos específicos podem ser observados no corpo textual das análises. O estudo das fontes históricas, como os relatórios de presidentes de Província, ainda no século XIX, apontam os aterramentos como um expediente corriqueiro. Aliada a esta descoberta, a observação da urbanização recente, sobretudo do Bairro Jardins (1996-1997) e dos assentamentos sobre os manguezais, concorreu para a delimitação temporal, à principio de 1855 2005. Não obstante, o marco de 150 anos culminaria por engessar as análises pertinentes ao tema e induziria à pretensão de uma história total dos manguezais aracajuanos, o que não é intuito desta pesquisa. Observa-se, através deste estudo, que as motivações para os aterros de manguezais aracajuanos apresentam uma continuidade temporal, e além disto, uma conivência da sociedade civil, na qual está inserido o poder público. Por fim, esta dissertação, enquanto estudo histórico da devastação e extinção parcial dos manguezais aracajuanos, não pretende julgar o homem aracajuano do passado, mas alertar para o risco de permanência da prática de aterros: a extinção total dos manguezais da cidade de Aracaju.
368

Tratamento de lixiviado através de filtro anaeróbio associado a membrana de microfiltração

Dacanal, Marisa 31 August 2006 (has links)
Atualmente, o uso de bioreatores associados a membranas (MBRs) tem sido pesquisado em muitos lugares do mundo para tratar diferentes tipos de efluentes. O uso de MBRs tem vantagens sobre outros processos quando o principal foco está na reutilização do efluente, pequenas áreas para o tratamento de efluentes ou condições restritivas da legislação. Normalmente, os MBRs são projetados com biomassa suspensa. O objetivo deste trabalho foi avaliar a performance de um reator anaeróbio e um reator anaeróbio associado a membrana de microfiltração tratando lixiviado de aterro sanitário em escala piloto. O material utilizado na membrana de microfiltação foi cerâmica (ver formula no documento original), com diâmetro de poro e área de filtração de 0,2 µm e 0,0094 m2, respectivamente. O rejeito da unidade de microfiltração retornava para o reator anaeróbio associado a membrana. Os resultados obtidos nesta pesquisa indicaram que é possível tratar lixiviado com esta configuração de MBR com um curto tempo de detenção hidráulica (2,04 d). O valor médio da concentração de DQO foi 10.359 mg O2/L na entrada dos reatores e, a carga orgânica volumétrica aplicada aos reatores foi de 5,07 mais ou menos 2,90 kg DQO/m3.d. A eficiência de remoção de DQO do reator anaeróbio associado a membrana foi de 90,4% como valor médio, contra 21,5% do reator anaeróbio. A eficiência de remoção de turbidez no reator anaeróbio associado a membrana de microfiltração foi de 90,3% apresentando valores de saída de 2,0 mais ou menos 2,0 NTU. Concentrações de sólidos suspensos na saída foram maiores no reator anaeróbio do que no reator anaeróbio associado a membrana, apesar da maior velocidade ascensional deste. A análise da biomassa dos reatores mostrou que houve uma melhor distribuição desta no reator anaeróbio associado a membrana de microfiltração do que no reator anaeróbio sem a membrana, devido ao reciclo do rejeito. A velocidade ascensional foi de 0,05 m/h no reator anaeróbio e 31,5 m/h no reator anaeróbio associado a membrana. O principal efeito destes valores de velocidade ascensional está no número de Reynolds calculado, o qual foi 2,9 para o reator anaeróbio e 1.799 para o reator anaeróbio associado a membrana. Embora ambos os reatores tenham sido projetados para atuar em fluxo laminar, o maior valor do número de Reynolds do reator anaeróbio associado a membrana produziu um maior coeficiente de transferência de massa e uma melhor taxa de utilização de substrato do que no reator anaeróbio sem a membrana. Este fato, juntamente com a retenção de biomassa e de compostos macromoleculares, explica uma melhor performance do reator anaeróbio associado a membrana de microfiltração. Os resultados do índice modificado de fouling (MFI) indicaram que este índice variou durante o processo, provavelmente devido a variações da pressão e de compostos presentes no lixiviado. O reator anaeróbio associado a membrana estabelece uma nova alternativa de tratamento de efluentes, eficiente, segura e ambientalmente correta. / Nowadays, the use of membrane bioreactors (MBRs) has been researched in many places of the world to treat different kinds of wastewater. The use of MBRs has advantages over other processes when the main focus is on the reuse of wastewater, small areas for wastewater treatment plant or restricted laws conditions. Commonly, the MBRs have been designed with suspended biomass. The goal of this work was to evaluate the performance of anaerobic reactor and anaerobic reactor associated with microfiltration membrane treating sanitary landfill leachate in pilot scale. The microfiltration membrane material used was ceramic (...) and its pore diameter and filtration area were 0.2 µm and 0.0094 m2, respectively. The retentate of the microfiltration unity was returned to the anaerobic reactor associated with microfiltration membrane. The results obtained in this research indicated that it is possible to treat leachate with this MBR configuration with a short hidraulic retention time (2.04 d). The mean value of COD concentration was 10,349 mg O2/L at the inlet of both reactors and the volumetric organic load for both reactors was 5.07 +- 2.90 kg DQO/m3.d. The membrane anaerobic reactor efficiency of COD removal was 90.4% as the mean value, against 21.5% of the anaerobic reactor. The efficiency of turbidity removal in the anaerobic reactor associated with microfiltration membrane was 90.3% with outlet values of 2.0 +- 2.0 NTU. Suspended solid concentrations at the outlet were higher in the anaerobic reactor than in the anaerobic reactor associated with microfiltration membrane, despite its higher upflow velocity. The analysis of biomass of both reactors showed that there was a better distribution of biomass in the anaerobic reactor associated with microfiltration membrane than the anaerobic reactor without microfiltration membrane, due to retentate recicling. The upflow velocity was 0.05 m/h in the anaerobic reactor and 31.5 m/h in the anaerobic reactor associated with microfiltration membrane. The main effect of these upflow velocity values was in the Reynolds number which was 2.9 for the anaerobic reactor and 1,799 for the anaerobic reactor associated with microfiltration membrane. Although both reactors had been designed to perform a laminar flow, the higher value of Reynolds number of the anaerobic reactor associated with microfiltration membrane produced a higher mass transfer coefficient and a better substrate utilization rate than the anaerobic reactor without microfiltration membrane. This is a reason, along with the retention of biomass and macromolecular compounds, that explains a better performance of the anaerobic reactor associated with microfiltration membrane. The results of modified fouling index (MFI) indicated that this index changed during the process, probably due the changes of pressure and compounds in the leachate. The anaerobic reactor associated with microfiltration membrane is a new option of wastewater treatment process, efficient, secure and an environmentally right alternative.
369

Fotocatalise de percolado de aterro sanitario tratado por filtração lenta / Sanitary landfill leachate photocatalysis treated by low sand filter

Pelegrini, Nubia Natalia de Brito 10 June 2008 (has links)
Orientador: Jose Euclides Stipp Paterniani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-08-11T19:36:37Z (GMT). No. of bitstreams: 1 Pelegrini_NubiaNataliadeBrito_D.pdf: 996195 bytes, checksum: 77e195562e461a19e9d3b633f0f102c1 (MD5) Previous issue date: 2008 / Resumo: Atualmente, uma das maiores preocupações ambientais está relacionada à grande geração de resíduos sólidos urbano. A disposição final em aterros sanitários é ainda uma prática que traz sérios impactos ao meio ambiente. Os resíduos em decomposição geram uma fração líquida conhecida como percolado de aterro sanitário, que é um líquido escuro com elevado potencial poluente. Os métodos convencionais de tratamento, comumente empregados em esgotos, têm demonstrado ineficiência na remediação do percolado que tem sido descartado nos corpos receptores com intensa coloração, elevadas concentrações de matéria orgânica, metais tóxicos e apresentando ainda alta toxicidade. Este trabalho teve como objetivo estudar um sistema integrado para o tratamento do percolado proveniente do aterro sanitário da cidade de Limeira-SP. O sistema consistiu em um tratamento preliminar por processo de filtração lenta e seqüencial tratamento por processos oxidativos avançados, sendo que, as técnicas fotocatálise heterogênea com TiO2/UV e fotocatálise homogênea com H2O2/UV foram experimentadas no processo de remediação. O filtro lento foi constituído por um tanque cilíndrico de polipropileno tendo como meio filtrante areia e mantas sintéticas não tecidas. A taxa de filtração adotada durante os experimentos foi de 3 m3/m2.dia. Os tratamentos fotocatalíticos foram realizados em um reator de vidro Pyrex com capacidade volumétrica de 1,7 L (com dimensões de: 100 mm de diâmetro interno, 145 mm de diâmetro externo e altura total de 300 mm) equipado com refrigeração à água e sistema de recirculação interna do percolado. Para otimizar o processo de tratamento foi avaliada a melhor metodologia para minimizar a coloração do percolado, um dos parâmetros de maior dificuldade de remoção. Foram estudadas as combinações: filtração lenta seguida de fotocatálise e fotocatálise seguida de filtração lenta, sendo que a primeira proposta apresentou melhores resultados. Na seqüência foram avaliadas as tecnologias: fotocatálise heterogênea com TiO2/UV e fotocatálise homogênea com H2O2/UV. Os resultados apresentaram-se bastante satisfatório após a aplicação dos dois processos oxidativos avançados, com redução da coloração do percolado na ordem de: 66% em 180 min e 76% em 540 min de tratamento com a fotocatálise heterogênea, empregando 700 mg.L-1 de TiO2, temperatura 45°C, vazão de ar 15 L.min-1 e lâmpada de 400 Watts. Com a fotocatálise homogênea obteve-se 91% de descoloração em 90 min de tratamento empregando condições experimentais otimizadas: volume de H2O2 35 mL (concentração: 205 mg.L-1 H2O2) adicionados ao reator em alíquotas de 15 mL (início); 10 mL (30 minutos) e 10 mL (60 minutos), temperatura 45oC e lâmpada de 400 Watts. Após a fotocatálise homogênea também foi observado reduções consideráveis nos valores de vários parâmetros importantes para o controle ambiental, tais como: 90% de turbidez, 46% de carbono orgânico total (COT), 93% de fenóis totais e 97% de nitrogênio amoniacal. Ensaios toxicológicos empregando sementes hortaliças e flores demonstraram melhora significativa no potencial de germinação, apresentando possibilidade de utilização de uma maior concentração do percolado tratado na germinação das sementes, indicando que o sistema de tratamento estudado é capaz de reduzir também a toxicidade do percolado. / Abstract: Nowadays, one of the great environmental concerns is related to the great generation of urbane solid residues. The final disposition in sanitary landfill is a practice that still brings serious impacts to the environment. The residues goes through physical, chemical and biological decomposition processes, generating into a gas phase (mainly composed by CH4 and CO2) and a liquid phase known as leachate, that is a dark liquid with potential pollutant high. The conventional methods used in the treatment of this residue lead to a discharge with intense coloration, high organic matter concentration, toxic metals and high toxicity. This work had as objective to study a system integrated for the remediation of the leachate originating from the sanitary landfill of Limeira-SP city The system consisted in a preliminary treatment by a system of slow sand filtration and the subsequent treatment through advanced oxidative processes, such as: heterogeneous photocatalysis UV/TiO2 and homogeneous photocatalysis UV/H2O2. The slow sand filter was constituted by a polypropylene cylindrical tank, sand and non-woven synthetic fabrics. The filtration rate of 3 m3/m2.day was adopted during the experiments. The photocatalytic treatment was accomplished in a Pyrex glass reactor of approximately 1.7 L (100 mm of internal diameter, 145 mm of external diameter and total height of 300 mm). The experiments were carried out through water refrigeration and internal recirculation system of the leachate. To optimize the treatment process the best methodology it was evaluated to minimize the coloration of the leachate, one of the parameters of larger removal difficulty. They were studied the combinations: slow filtration followed by fotocatálise and fotocatálise followed by slow filtration, and the first proposal presented better results. In the sequence they were evaluated the technologies: photocatalysis UV/TiO2 and homogeneous photocatalysis UV/H2O2. The results were satisfactory after the application of the two advanced oxidativos processes, with leachate coloration reduction in the order of: 66% in 180 min and 76% in 540 min of treatment with the heterogeneous fotocatálise, using 700 mg.L-1 of TiO2, 45°C temperature, 15 L.min-1 air flow and 400 Watts lamp. The highest reduction of the leachate coloration was 91% using the following optimized experimental conditions: homogeneous photocatalysis with H2O2 35 mL added to the reactor in aliquots of 15 mL (starting), 10 mL (30 minutes), 10 mL (60 minutes), 45oC temperature, 400 Watts lamp and 90 minutes treatment time. After the homogeneous photocatalysis also was observed considerable reduction of the values of environmental control parameters, such as: 90% turbidez, 46% total organic carbon (TOC), 93% total phenols and 97% amoniacal nitrogen. For the toxicological studies the vegetables and flowers seeds germination potential after homogeneous photocatalytic treatment got better, presenting the possibility of use of a leachate concentration larger in the seeds germination in study, showing that the treatment can to also reduce the leachate toxicity. / Doutorado / Agua e Solo / Mestre em Engenharia Agrícola
370

Análise das rotas tecnológicas existentes para os resíduos sólidos urbanos no município de Cidade Ocidental/GO / Analysis of existing routes technology for solid waste in the municipality of Cidade Ocidental/GO

Colvero, Diogo Appel 30 April 2014 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2014-11-04T10:49:17Z No. of bitstreams: 2 Dissertação - Diogo Appel Colvero - 2014.pdf: 2918191 bytes, checksum: cee2a535c176008af07f390b66b2790f (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2014-11-04T14:22:28Z (GMT) No. of bitstreams: 2 Dissertação - Diogo Appel Colvero - 2014.pdf: 2918191 bytes, checksum: cee2a535c176008af07f390b66b2790f (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2014-11-04T14:22:28Z (GMT). No. of bitstreams: 2 Dissertação - Diogo Appel Colvero - 2014.pdf: 2918191 bytes, checksum: cee2a535c176008af07f390b66b2790f (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2014-04-30 / The treatment and final disposal of solid waste (MSW) have raised concern and been the subject of intense debate, especially after the Law nº 12.305 of 2 August of 2010 which established the National Policy of Solid Waste (BRASIL, 2010a) . This Law established that municipalities would have up to four years to give a final environmentally correct their waste, from its publication layout. However, in Goiás, only fourteen of the 246 municipalities in the state currently have a landfill licensed by the Department of the Environment and Water Resources, of Goiás State (DEWR/GO). Thinking about it, aimed a municipality in the state who possessed a system of allocation of their MSW that targets minimizing impacts to the environment. picked up Cidade Ocidental/GO, a municipality that is part of the Integrated Development Region of the Distrito Federal and Surrounding Areas (IDRSA/DF), which has two different technological routes for disposal of solid waste: the first route, part of that waste is collected selectively and sent to a central screening called Association of Workers in Recycling and Reuse of Waste (AWRRW) and; in the second route, the remaining waste is conventionally collected and sent to landfill, which is operated by a private company, with that receives not only MSW Cidade Ocidental but also of Valparaíso de Goiás/GO - neighboring municipality to the city in study - thus forming a unique system in Goiás landfill shared. This system complies with the PNRS, which suggests the formation of consortia/sharing between cities, as well as the government will prioritize resources to municipalities that seek to unite to give a destination to their MSW. The objective of this study was to evaluate the technical, economic and environmental aspects existing of technological routes MSW municipality of Cidade Ocidental. For this, we carried out desk research by collecting secondary data and primary data collection also about technological routes of MSW city in study. The first route, the selective collecting-sorting central is not shared, because covers only the municipality of Cidade Ocidental, around 33.550 people attended. The current cost to maintain this system is R$ 375,58 per ton collected . The second route, the conventional collection-landfill is shared, also attending Valparaíso de Goiás, with about 190.000 people contemplated. To collect of form conventional and dispose at the landfill, the concessionaire, which forms with prefecture of Cidade Ocidental a public-private partnership of municipalities charge R$ 156,55 per tonne. The route of selective collecting-sorting central has some problems, which if corrected, can serve as a model for other municipalities in the state. And the second route, the conventional collection-landfill, has problems in public-private partnership, because the landfill is not the infrastructure and operation under ideal conditions, besides being with the license unsuccessful operation. However, if the mismatches are corrected, the landfill shared is a viable alternative to the municipalities of the state of Goiás. / O tratamento e a disposição final adequada dos resíduos sólidos urbanos (RSU) têm gerado preocupação e sido tema de intensos debates, principalmente, após a Lei nº. 12.305 de 2 de agosto de 2010 que instituiu a Política Nacional dos Resíduos Sólidos – PNRS (BRASIL, 2010a). Esta Lei estabeleceu que os municípios teriam até quatro anos para dar uma disposição final ambientalmente correta aos seus rejeitos, a partir da sua publicação. Entretanto, em Goiás, apenas quatorze dos 246 municípios do estado possuem atualmente um aterro sanitário licenciado pela Secretaria do Meio Ambiente e dos Recursos Hídricos do Estado de Goiás (SEMARH/GO). Pensando nisso, buscou-se um município do estado que possuísse um sistema de destinação de seus RSU que visasse minimizar os impactos ao meio ambiente. Escolheu-se Cidade Ocidental/GO, um município que faz parte da Região Integrada de Desenvolvimento do Distrito Federal e Entorno (RIDE/DF), e que possui duas rotas tecnológicas distintas para destinação de seus resíduos sólidos: na primeira rota, parte desses resíduos são coletados seletivamente e encaminhados à uma central de triagem denominada Associação dos Trabalhadores em Reciclagem e Reaproveitamento de Lixo (ASLURB) e; na segunda rota, o restante dos resíduos é coletado convencionalmente e enviado para o aterro sanitário, que é operado por uma empresa privada, sendo que esse recebe não só os RSU de Cidade Ocidental mas também os de Valparaíso de Goiás/GO - município vizinho à cidade em estudo - formando assim um sistema inédito em Goiás de aterro sanitário compartilhado. Este sistema está de acordo com a PNRS, que sugere a formação de consórcios/compartilhamento entre entes federados, assim como o governo irá priorizar recursos para os municípios que buscarem se unir para dar uma destinação aos seus RSU. Objetivou-se neste estudo avaliar os aspectos técnico-econômicos e socioambientais das rotas tecnológicas existentes para os RSU do município de Cidade Ocidental. Para isso, realizou-se uma pesquisa documental por meio de coleta de dados secundários e também levantamento de dados primários acerca das rotas tecnológicas dos RSU da cidade em estudo. A primeira rota, da coleta seletiva-central de triagem não é compartilhada, pois abrange somente o município de Cidade Ocidental, em torno de 33.550 habitantes atendidos. O custo atual para a manutenção desse sistema é de R$ 375,58 por tonelada coletada. Já a segunda rota, da coleta convencional-aterro sanitário é compartilhada, atendendo também Valparaíso de Goiás, com cerca de 190.000 habitantes contemplados. Para coletar de forma convencional e dispor no aterro sanitário, a concessionária, que forma com a prefeitura de Cidade Ocidental uma parceria público-privada, cobra dos municípios R$ 156,55 por tonelada. A rota da coleta seletiva-central de triagem possui alguns problemas, que se forem corrigidos, pode servir de modelo para os demais municípios do estado. E a segunda rota, da coleta convencional-aterro sanitário, possui problemas na parceria público-privada, pois o aterro sanitário não está com a infraestrutura e operação nas condições ideais, além de estar com a licença de operação vencida. Contudo, se as inadequações forem corrigidas, o aterro sanitário compartilhado é uma alternativa viável para os municípios do estado de Goiás.

Page generated in 0.043 seconds