• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Aplicação da metodologia fuzzy na quantificação da probabilidade de erro humano em instalações nucleares / Human error probability quantification using fuzzy methodology in nuclear plants

Nascimento, Claudio Souza do 24 February 2010 (has links)
Neste trabalho foram obtidas estimativas das Probabilidades de Erro Humano (PEH) das ações dos operadores do Reator de Pesquisa IEA-R1 do IPEN, em resposta a uma hipótese de situação de emergência, e realizada uma avaliação dos Fatores Influenciadores do Desempenho Humano (PSF) potencialmente influentes naquelas ações. A avaliação dos PSF foi realizada com a finalidade de classificá-los de acordo com o seu nível de influência nas ações e de determinar o estado atual destes PSF na instalação. Tanto a obtenção das PEH, como também a avaliação dos PSF, foram realizadas por meio do processo de Avaliação por Especialistas, através de entrevistas e questionários. O grupo especialista foi composto a partir dos próprios operadores do Reator IEA-R1. A representação do conhecimento dos especialistas em expressões lingüísticas e a geração de valores que representam o consenso das avaliações do grupo especialista deram-se pelo emprego da Lógica Fuzzy e da Teoria dos Conjuntos Fuzzy. Os valores obtidos para as PEH foram comparados com dados utilizados pela literatura afim e se mostraram satisfatórios para ações similares, corroborando a metodologia proposta como uma boa alternativa a ser empregada em métodos de Análises de Confiabilidade Humana (ACH). / This work obtains Human Error Probability (HEP) estimates from operator\'s actions in response to emergency situations a hypothesis on Research Reactor IEA-R1 from IPEN. It was also obtained a Performance Shaping Factors (PSF) evaluation in order to classify them according to their influence level onto the operator\'s actions and to determine these PSF actual states over the plant. Both HEP estimation and PSF evaluation were done based on Specialists Evaluation using interviews and questionnaires. Specialists group was composed from selected IEA-R1 operators. Specialist\'s knowledge representation into linguistic variables and group evaluation values were obtained through Fuzzy Logic and Fuzzy Set Theory. HEP obtained values show good agreement with literature published data corroborating the proposed methodology as a good alternative to be used on Human Reliability Analysis (HRA).
2

Aplicação da metodologia fuzzy na quantificação da probabilidade de erro humano em instalações nucleares / Human error probability quantification using fuzzy methodology in nuclear plants

Claudio Souza do Nascimento 24 February 2010 (has links)
Neste trabalho foram obtidas estimativas das Probabilidades de Erro Humano (PEH) das ações dos operadores do Reator de Pesquisa IEA-R1 do IPEN, em resposta a uma hipótese de situação de emergência, e realizada uma avaliação dos Fatores Influenciadores do Desempenho Humano (PSF) potencialmente influentes naquelas ações. A avaliação dos PSF foi realizada com a finalidade de classificá-los de acordo com o seu nível de influência nas ações e de determinar o estado atual destes PSF na instalação. Tanto a obtenção das PEH, como também a avaliação dos PSF, foram realizadas por meio do processo de Avaliação por Especialistas, através de entrevistas e questionários. O grupo especialista foi composto a partir dos próprios operadores do Reator IEA-R1. A representação do conhecimento dos especialistas em expressões lingüísticas e a geração de valores que representam o consenso das avaliações do grupo especialista deram-se pelo emprego da Lógica Fuzzy e da Teoria dos Conjuntos Fuzzy. Os valores obtidos para as PEH foram comparados com dados utilizados pela literatura afim e se mostraram satisfatórios para ações similares, corroborando a metodologia proposta como uma boa alternativa a ser empregada em métodos de Análises de Confiabilidade Humana (ACH). / This work obtains Human Error Probability (HEP) estimates from operator\'s actions in response to emergency situations a hypothesis on Research Reactor IEA-R1 from IPEN. It was also obtained a Performance Shaping Factors (PSF) evaluation in order to classify them according to their influence level onto the operator\'s actions and to determine these PSF actual states over the plant. Both HEP estimation and PSF evaluation were done based on Specialists Evaluation using interviews and questionnaires. Specialists group was composed from selected IEA-R1 operators. Specialist\'s knowledge representation into linguistic variables and group evaluation values were obtained through Fuzzy Logic and Fuzzy Set Theory. HEP obtained values show good agreement with literature published data corroborating the proposed methodology as a good alternative to be used on Human Reliability Analysis (HRA).
3

Contribuição para seleção de dez indicadores de qualidade em terapia nutricional / Contribution to selection of the ten quality indicators for nutritional therapy

Verotti, Cristiane Comeron Gimenez 07 December 2012 (has links)
INTRODUÇÃO: Indicadores de qualidade em terapia nutricional (IQTN) são importantes ferramentas de avaliação e monitoramento de qualidade da terapia nutricional (TN). No Brasil, além da escassez de recursos humanos e materiais, a aplicação dos IQTNs,disponíveis para prática clínica, tem sido limitada devido ao seu elevado número. O presente estudo procurou identificar os dezIQTNs mais pontuados, dentre aqueles disponíveis no Brasil, através da avaliação da opinião de especialistas em TN. MÉTODOS: Todos os IQTNs disponíveis para aplicação clínica no Brasil (n=36) foram avaliados em duas fases distintas. Na fase 1 (seleção), especialistas em TN (n=26) pontuaramos IQTNs de acordo com quatro atributos (utilidade, simplicidade, objetividade, e baixo custo), utilizando a escala de Likert com 5 pontos. Os IQTNs foram classificadosem ordem da maior para menor pontuação e a confiabilidade da opinião de especialistas para cada indicador foi avaliada poralfa de Cronbach. Na fase 2, os dez IQTNs selecionados com maior pontuaçãoforam submetidos ànova análise dos especialistas, por meio de duas perguntas fechadas. RESULTADOS: Os dez IQTNs selecionadoscom maior pontuação, em ordem do mais para o menos pontuado, foram 1.) Frequência de realização de triagem nutricional em pacientes hospitalizados, 2.) Frequência de diarreia em pacientes em Terapia Nutricional Enteral, 3.) Frequência de saída inadvertida de sonda de nutrição em pacientes em Terapia Nutricional Enteral, 4.) Frequência de obstrução de sonda de nutrição em pacientes em Terapia Nutricional Enteral, 5.) Frequência de jejum digestório por mais de 24 horas em pacientes em Terapia Nutricional Enteral ou Oral, 6.) Frequência de pacientes com disfunção da glicemia em Terapia Nutricional Enteral e Parenteral, 7.) Frequência de medida ou estimativa do gasto energético e necessidades proteicas em pacientes em Terapia Nutricional, 8.) Frequência de infecção por Cateter Venoso Central em pacientes em Terapia Nutricional Parenteral, 9.) Frequência de conformidade de indicação da Terapia Nutricional Enteral, 10.) Frequência de aplicação de Avaliação Subjetiva Global (ASG) em pacientes em Terapia Nutricional. As opiniões dos especialistas entrevistados foram significantemente consistentes. Durante a fase 2, 96% dos especialistas informaram estar satisfeitos com os 10 IQTNs selecionados, e 100% manifestaram que esta seleção refletiu a mesma opinião anteriormente emitida,na primeira fase do estudo. CONCLUSÃO: A avaliação da opinião de especialistas em TN, com o uso de técnicas psicométricas e ferramentas estatísticas, possibilitou a identificação dedezIQTNsmais pontuados,com consistência e representatividade de opiniões entre eles.A redução do número de trinta e seis IQTNs para os dez presentemente identificados pode contribuir para sua aplicação clínica / BACKGROUND: Quality indicators in nutritional therapy (QINT) are central tools to evaluate and monitor the quality of nutritional therapy. In addition to the scarcity of human and material resources, the application of the QINT available for clinical practice in Brazil has been limited also due to its elevated number. This study attempted to identify the ten more scored QINT that suit in the clinical practice, among those available in Brazil, through evaluating experts in Nutritional Therapy (NT). METHODS: All the 36 available QINTs to the clinical application in Brazil were evaluated in two distinct phases. In the phase 1 (selection), 26 experts in NT rated the QINTs following four attributes (utility, simplicity, objectivity and low cost), on a 5- point Likert scale. The top 10 QINTs were identified from the top 10 scores; and the reliability of the experts opinion to each indicator were evaluated by Cronbachs alpha. In phase 2, the top 10 selected QINTs were subjected in a new experts analysis following two closed questions. RESULTS: The top 10 selected QINTs, from the biggest to the least scored order, were: 1) Frequency of carrying out nutrition screening of hospitalized patients, 2) Frequency of diarrhea in patients on Enteral Nutrition (EN), 3) Frequency of involuntary withdrawal of enteral feeding tubes, 4) Frequency of tube feeding occlusion in patients on EN, 5) Frequency of digestive fasting for more than 24 hours in patients on oral nutrition or EN, 6) Frequency of patients with glycemic dysfunction on NT, 7) Frequency of measurement or estimation of energy expenditure and protein needs in patients on NT, 8) Frequency of Central Venous Catheter infection in patients on Parenteral Nutrition, 9) Frequency of indication compliance of NT 10) Frequency of application of Subjective Global Assessment in patients on NT. The opinions of the experts interviewed were significantly consistent. During the phase 2, 96% of the experts were found to be satisfied with the top 10 selected QINTs, and 100% expressed that the selection of the top 10 QINTs interfered the same opinion in the first phase of the study. CONCLUSION: The evaluation of the experts opinion in NT using psychometrics techniques and statistical tools, allowed the identification of the 10 most scored QINTs, with good applicability in NT and representativeness of opinions among them. The reduction of QINT number from 36 to ten, may contribute to their clinical application
4

Contribuição para seleção de dez indicadores de qualidade em terapia nutricional / Contribution to selection of the ten quality indicators for nutritional therapy

Cristiane Comeron Gimenez Verotti 07 December 2012 (has links)
INTRODUÇÃO: Indicadores de qualidade em terapia nutricional (IQTN) são importantes ferramentas de avaliação e monitoramento de qualidade da terapia nutricional (TN). No Brasil, além da escassez de recursos humanos e materiais, a aplicação dos IQTNs,disponíveis para prática clínica, tem sido limitada devido ao seu elevado número. O presente estudo procurou identificar os dezIQTNs mais pontuados, dentre aqueles disponíveis no Brasil, através da avaliação da opinião de especialistas em TN. MÉTODOS: Todos os IQTNs disponíveis para aplicação clínica no Brasil (n=36) foram avaliados em duas fases distintas. Na fase 1 (seleção), especialistas em TN (n=26) pontuaramos IQTNs de acordo com quatro atributos (utilidade, simplicidade, objetividade, e baixo custo), utilizando a escala de Likert com 5 pontos. Os IQTNs foram classificadosem ordem da maior para menor pontuação e a confiabilidade da opinião de especialistas para cada indicador foi avaliada poralfa de Cronbach. Na fase 2, os dez IQTNs selecionados com maior pontuaçãoforam submetidos ànova análise dos especialistas, por meio de duas perguntas fechadas. RESULTADOS: Os dez IQTNs selecionadoscom maior pontuação, em ordem do mais para o menos pontuado, foram 1.) Frequência de realização de triagem nutricional em pacientes hospitalizados, 2.) Frequência de diarreia em pacientes em Terapia Nutricional Enteral, 3.) Frequência de saída inadvertida de sonda de nutrição em pacientes em Terapia Nutricional Enteral, 4.) Frequência de obstrução de sonda de nutrição em pacientes em Terapia Nutricional Enteral, 5.) Frequência de jejum digestório por mais de 24 horas em pacientes em Terapia Nutricional Enteral ou Oral, 6.) Frequência de pacientes com disfunção da glicemia em Terapia Nutricional Enteral e Parenteral, 7.) Frequência de medida ou estimativa do gasto energético e necessidades proteicas em pacientes em Terapia Nutricional, 8.) Frequência de infecção por Cateter Venoso Central em pacientes em Terapia Nutricional Parenteral, 9.) Frequência de conformidade de indicação da Terapia Nutricional Enteral, 10.) Frequência de aplicação de Avaliação Subjetiva Global (ASG) em pacientes em Terapia Nutricional. As opiniões dos especialistas entrevistados foram significantemente consistentes. Durante a fase 2, 96% dos especialistas informaram estar satisfeitos com os 10 IQTNs selecionados, e 100% manifestaram que esta seleção refletiu a mesma opinião anteriormente emitida,na primeira fase do estudo. CONCLUSÃO: A avaliação da opinião de especialistas em TN, com o uso de técnicas psicométricas e ferramentas estatísticas, possibilitou a identificação dedezIQTNsmais pontuados,com consistência e representatividade de opiniões entre eles.A redução do número de trinta e seis IQTNs para os dez presentemente identificados pode contribuir para sua aplicação clínica / BACKGROUND: Quality indicators in nutritional therapy (QINT) are central tools to evaluate and monitor the quality of nutritional therapy. In addition to the scarcity of human and material resources, the application of the QINT available for clinical practice in Brazil has been limited also due to its elevated number. This study attempted to identify the ten more scored QINT that suit in the clinical practice, among those available in Brazil, through evaluating experts in Nutritional Therapy (NT). METHODS: All the 36 available QINTs to the clinical application in Brazil were evaluated in two distinct phases. In the phase 1 (selection), 26 experts in NT rated the QINTs following four attributes (utility, simplicity, objectivity and low cost), on a 5- point Likert scale. The top 10 QINTs were identified from the top 10 scores; and the reliability of the experts opinion to each indicator were evaluated by Cronbachs alpha. In phase 2, the top 10 selected QINTs were subjected in a new experts analysis following two closed questions. RESULTS: The top 10 selected QINTs, from the biggest to the least scored order, were: 1) Frequency of carrying out nutrition screening of hospitalized patients, 2) Frequency of diarrhea in patients on Enteral Nutrition (EN), 3) Frequency of involuntary withdrawal of enteral feeding tubes, 4) Frequency of tube feeding occlusion in patients on EN, 5) Frequency of digestive fasting for more than 24 hours in patients on oral nutrition or EN, 6) Frequency of patients with glycemic dysfunction on NT, 7) Frequency of measurement or estimation of energy expenditure and protein needs in patients on NT, 8) Frequency of Central Venous Catheter infection in patients on Parenteral Nutrition, 9) Frequency of indication compliance of NT 10) Frequency of application of Subjective Global Assessment in patients on NT. The opinions of the experts interviewed were significantly consistent. During the phase 2, 96% of the experts were found to be satisfied with the top 10 selected QINTs, and 100% expressed that the selection of the top 10 QINTs interfered the same opinion in the first phase of the study. CONCLUSION: The evaluation of the experts opinion in NT using psychometrics techniques and statistical tools, allowed the identification of the 10 most scored QINTs, with good applicability in NT and representativeness of opinions among them. The reduction of QINT number from 36 to ten, may contribute to their clinical application

Page generated in 0.1108 seconds