• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 12
  • Tagged with
  • 13
  • 9
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Tecnologia dos curativos no tratamento das feridas cirúrgicas infectadas: elementos essenciais no processo de escolha do(a) enfermeiro(a)

Silva, Adriana Peixoto da January 2004 (has links)
Made available in DSpace on 2014-02-26T19:13:29Z (GMT). No. of bitstreams: 2 license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) 53351.pdf: 653249 bytes, checksum: 691b1a130cdd295adda1f6d4f79a6c4c (MD5) Previous issue date: 2013-07-22 / Fundação Oswaldo Cruz. Instituto Fernandes Figueira. Departamento de Ensino. Programa de Pós-Graduação em Saúde da Criança e da Mulher. Rio de Janeiro, RJ, Brasil. / Trata-se de uma pesquisa qualitativa e exploratória que pretende produzir conhecimentos que possam fundamentar e aperfeiçoar a escolha do(a) enfermeiro(a) frente ao tratamento de feridas cirúrgicas infectadas, isto é, a escolha por uma tecnologia de curativos apropriada ao tipo de ferida. Os sujeitos do estudo são oito enfermeiras que desenvolvem atividades assistenciais no Departamento de Neonatologia do Instituto Fernandes Figueira, sendo cinco diaristas e três plantonistas diurnas. O estudo identificou sete fases que o(a) enfermeiro(a) deve percorrer para sistematizar o processo de escolha da tecnologia apropriada aos curativos no tratamento de feridas cirúrgicas infectadas. O estudo concluiu que, pelos menos, três fases deste processo devem ser necessariamente cumpridas: a identificação do problema, a análise das causas e dos fatores relacionados com o problema e a fase de decisão propriamente dita. Com o domínio destas três fases do processo, o(a) enfermeiro(a) deverá estar suficientemente capacitado(a) a desenvolver as demais fases.
2

Efeitos da compressão abdominal com faixa nos parâmetros respiratórios em voluntários normais / Effects of external abdominal compression in respiratory parameters in healthy volunteers

Wagana, Viviane Morbelli 30 August 2004 (has links)
Introdução: Durante a inspiração, o diafragma contrai e abaixa o centro frênico aumentando o diâmetro vertical do tórax. Entretanto, o conteúdo abdominal impede a excursão diafragmática. Os músculos abdominais funcionam como uma cinta segurando as vísceras abdominais, ajudando a o diafragma a aumentar a pressão intra-abdominal. Na expiração forçada, os músculos abdominais contraem e comprimem o abdômen elevando o diafragma. Objetivo: Analisar os efeitos da compressão abdominal com faixa, até diminuir de -10% e -15% da circunferência abdominal inicial, avaliando a freqüência respiratória (FR),volume corrente (VC), capacidade vital forçada (CVF), pressão inspiratória máxima (PImax) e pressão expiratória máxima (PEmax) em voluntários normais. Métodos: Foram avaliados 26 voluntários normais, idade média de 24 anos ? 4anos, 14 mulheres e 12 homens, em respiração espontânea foram submetidos à medida da circunferência abdominal. Foram medidos também FR, VC, CVF, Pimax e PEmax. Depois, repetimos as medidas após a compressão abdominal com -10% e -15% da circunferência de base. Depois, retiramos a faixa compressiva e medimos novamente os parâmetros. Resultados: Com compressão de -10%, houve diminuição do VC de 517 mL 456,86 mL (p < 0,005) e Pimax de -111cmH20 para -96 cmH20 (p < 0,005). Após a compressão de -15%, além da diminuição dos parâmetros anteriores, observamos também a diminuição da PEmax de 120 cmH20 para 100 cmH20 (p < 0,005). Após a retirada da faixa, os valores voltaram próximos aos iniciais. Conclusão: A compressão abdominal de -10 e -15% com faixa diminui o VC, PImax e PEmax (a última apenas com -15%) e não afeta a FR e a CVF / Background: During the inspiration, the diaphragm contracts and pulls down the central tendon and rises the vertical thoracic diameter. However, the abdominal container resistance forbids the diaphragmatic excursion. The abdominal organs are contained by a strong muscle binder that helps the diaphragm increasing the intra-abdominal pressure, allowing the inferior rib cage to go upward. In deep expiration, strong contractions of abdominal muscles constrict and compress the abdomen, helping to elevate the relaxing diaphragm. Objectives: To analyse the effects of -10% and -15% of the baseline abdominal circumference compression with a band in the respiratory rate (RR), tidal volume (TV), forced vital capacity (FVC) and maximal inspiratory (MIP) and expiratory pressures (MEP) in normal volunteers. Methods: Twenty six normal volunteers, mean age of 24 ? 4 years, 14 female and 12 male, in spontaneous breathing were submitted to abdominal circunference measurement. Thereafter, we obtained their RR, TV, FVC, MIP and MEP. Then, we repeated the measures after compression of abdomen using an external band to achieve - 10% and - 15% of the basal abdominal circumference. Then, we took out the band and measured the respiratory parameters again. Results: With -10% abdominal compression, TV decreased from 517 mL to 456,86 mL (p < 0,005) and MIP decreased from -111 cmH20 to -96 cmH20 (p < 0,005). Then, after -15% abdominal compression, we could observe a decrease in MEP: 120 cmH20 to 100 cmH20 (p < 0,005). After taking out the band, the respiratory parameters returned next to the basal measurements. Conclusion: The abdominal compression of -10% and -15% with an external band decreased TV, MIP and MEP (the last one only with - 15% compression) and didn\'t affect RR and FVC.
3

Efeitos da compressão abdominal com faixa nos parâmetros respiratórios em voluntários normais / Effects of external abdominal compression in respiratory parameters in healthy volunteers

Viviane Morbelli Wagana 30 August 2004 (has links)
Introdução: Durante a inspiração, o diafragma contrai e abaixa o centro frênico aumentando o diâmetro vertical do tórax. Entretanto, o conteúdo abdominal impede a excursão diafragmática. Os músculos abdominais funcionam como uma cinta segurando as vísceras abdominais, ajudando a o diafragma a aumentar a pressão intra-abdominal. Na expiração forçada, os músculos abdominais contraem e comprimem o abdômen elevando o diafragma. Objetivo: Analisar os efeitos da compressão abdominal com faixa, até diminuir de -10% e -15% da circunferência abdominal inicial, avaliando a freqüência respiratória (FR),volume corrente (VC), capacidade vital forçada (CVF), pressão inspiratória máxima (PImax) e pressão expiratória máxima (PEmax) em voluntários normais. Métodos: Foram avaliados 26 voluntários normais, idade média de 24 anos ? 4anos, 14 mulheres e 12 homens, em respiração espontânea foram submetidos à medida da circunferência abdominal. Foram medidos também FR, VC, CVF, Pimax e PEmax. Depois, repetimos as medidas após a compressão abdominal com -10% e -15% da circunferência de base. Depois, retiramos a faixa compressiva e medimos novamente os parâmetros. Resultados: Com compressão de -10%, houve diminuição do VC de 517 mL 456,86 mL (p < 0,005) e Pimax de -111cmH20 para -96 cmH20 (p < 0,005). Após a compressão de -15%, além da diminuição dos parâmetros anteriores, observamos também a diminuição da PEmax de 120 cmH20 para 100 cmH20 (p < 0,005). Após a retirada da faixa, os valores voltaram próximos aos iniciais. Conclusão: A compressão abdominal de -10 e -15% com faixa diminui o VC, PImax e PEmax (a última apenas com -15%) e não afeta a FR e a CVF / Background: During the inspiration, the diaphragm contracts and pulls down the central tendon and rises the vertical thoracic diameter. However, the abdominal container resistance forbids the diaphragmatic excursion. The abdominal organs are contained by a strong muscle binder that helps the diaphragm increasing the intra-abdominal pressure, allowing the inferior rib cage to go upward. In deep expiration, strong contractions of abdominal muscles constrict and compress the abdomen, helping to elevate the relaxing diaphragm. Objectives: To analyse the effects of -10% and -15% of the baseline abdominal circumference compression with a band in the respiratory rate (RR), tidal volume (TV), forced vital capacity (FVC) and maximal inspiratory (MIP) and expiratory pressures (MEP) in normal volunteers. Methods: Twenty six normal volunteers, mean age of 24 ? 4 years, 14 female and 12 male, in spontaneous breathing were submitted to abdominal circunference measurement. Thereafter, we obtained their RR, TV, FVC, MIP and MEP. Then, we repeated the measures after compression of abdomen using an external band to achieve - 10% and - 15% of the basal abdominal circumference. Then, we took out the band and measured the respiratory parameters again. Results: With -10% abdominal compression, TV decreased from 517 mL to 456,86 mL (p < 0,005) and MIP decreased from -111 cmH20 to -96 cmH20 (p < 0,005). Then, after -15% abdominal compression, we could observe a decrease in MEP: 120 cmH20 to 100 cmH20 (p < 0,005). After taking out the band, the respiratory parameters returned next to the basal measurements. Conclusion: The abdominal compression of -10% and -15% with an external band decreased TV, MIP and MEP (the last one only with - 15% compression) and didn\'t affect RR and FVC.
4

Uso da Bota de Unna comparado à bandagem elástica em úlceras venosas: estudo clínico

Abreu, Alcione Matos de January 2012 (has links)
Submitted by Fabiana Gonçalves Pinto (benf@ndc.uff.br) on 2015-11-26T18:23:43Z No. of bitstreams: 1 Alcione Matos de Abreu.pdf: 2227189 bytes, checksum: f73eb32bdd92709cccf5f1c0b4627d4d (MD5) / Made available in DSpace on 2015-11-26T18:23:43Z (GMT). No. of bitstreams: 1 Alcione Matos de Abreu.pdf: 2227189 bytes, checksum: f73eb32bdd92709cccf5f1c0b4627d4d (MD5) Previous issue date: 2012 / Universidade Federal Fluminense. Escola de Enfermagem Aurora de Afonso Costa / Este estudo teve os objetivos de avaliar os resultados clínicos e evolutivos do processo de reparo teci-dual em pacientes com úlcera venosa em uso da terapia compressiva inelástica (Bota de Unna) em comparação ao uso da terapia compressiva elástica (atadura elástica); e, analisar se existe variação significativa na área da úlcera ao longo de 13 semanas de tratamento nos dois grupos. Metodologia: Trata-se de um estudo clínico experimental randomizado e controlado, aberto, prospectivo, com abor-dagem quantitativa, realizado em um hospital universitário. A amostra foi de 18 pacientes, acompa-nhados por 13 semanas. Para alocação aleatória foi realizada uma lista através do software Biostat 5.0 que realizou o sorteio dos participantes em um dos grupos, onde metade destes utilizaram como trata-mento para as úlceras venosas a Bota de Unna, e a outra metade a atadura elástica. Todos os voluntá-rios atenderam aos critérios de inclusão. Este estudo foi aprovado pelo Comitê de Ética em Pesquisa da Faculdade de Medicina, sob o protocolo nº 327/2010 e CAAE:0252.0.258-000-10, os termos de consentimento e fotografia encontram-se de acordo com as Resoluções 196/96. A coleta de dados foi realizada durante seis meses, pela enfermeira pesquisadora e por uma bolsista de iniciação científica. Os dados foram analisados no SPSS 14.0 Windows, através de estatística descritiva e inferencial, e apresentados na forma de tabelas, quadros e gráficos. Entre os pesquisados, pôde-se identificar que (61,1%) eram homens e adultos, moradores de Niterói /RJ (66,6%) e com baixo grau de escolaridade (55,5%). Em relação às características clínicas das úlceras, encontrou-se que no grupo B, úlceras mais exsudativas, com maior tempo de evolução e maiores áreas. Já o Grupo A apresentou o maior numero de úlceras com presença no leito com tecido de hipergranulação e ou desvitalizado e destacou-se como a terapia compressiva mais confortável. O uso da Bota de Unna macerou as bordas das úlceras e a Gaze Petrolatum® levou a formação de crostas perilesional. Em relação a redução da área das úlceras venosas, pelo teste de ANOVA de Friedman, observou-se que existe queda significativa, ao nível de 5%, na área da úlcera apenas no grupo B (p < 0,0001) ao longo de todo o tratamento, mas pode-se dizer, que existe uma tendência do grupo A apresentar queda na área da lesão (p = 0,06), após a 5ª consulta. Conclui-se que a Bota de Unna apresentou melhor resultado em úlceras venosas com áreas superiores a 10 cm² e o uso da Gaze Petrolatum® com a atadura elástica em úlceras venosas inferiores a 10 cm². / This study aimed to evaluate clinical and evolutionist results of the process of tissues repairing in pa-tients with venous ulcer using the compressive inelastic (Unna Boot) comparing the usage of compres-sive elastic therapy (elastic bandage) and analyzing if there is a meaningful variation in the ulcer area with 13 weeks of treatment in both groups. Methodology: Concerning in a experimental, randomized and controlled, opened, prospective study with quantitative approach in a College Hospital. A sample of 18 patients was monitoring for 13 weeks. It was achieved a list of two groups in randomized draw by Biostat 5.0 software where half of participants used as therapy Unna Boot in venous ulcer and the other half of them used the elastic bandage one. All volunteers followed the inclusion criteria. This study was approved by The Committee of Ethics in research of Medical College; under the protocol number no 327/2010 and CAAE: 0252.0.258-000-10, terms of authorization and photography are in agreement to the resolutions 196/96. The data collection was done for six months by researcher nurse and a scholarship student of scientific study. Such data were analyzed in SAS 6.11, through descrip-tive and inferential statistic and performed in tables, squares and graphs. Among participants could identify that (61%) were adult male; inhabitants from Niteroi/RJ (66,6%) with a low degree of educa-tion (55,5%). Regarding to the ulcer clinical characteristics in Unna Boot group was found ulcers with more exsudation, with longer evolution time and larger areas. In elastic bandage group, a great number of ulcers with hyper-granulation and or desvitalization tissue on the bed was remarkable as the most comfortable compressive therapy. The usage of Unna Boot softened the ulcer borders and in the Petro-latum® Gaze took as a result a formation of a scab around the lesion. In relation to the reduction of venous ulcer area due to the ANOVA Friedman Test, analyzed that there is a meaningful decrease to the level of 5%, in the ulcer area in group B (p<0,0001) along of all the treatment, but there is a ten-dency of group A in performing a reduction in the affected area after the 5th consultation. Concluding that the Unna Boot performed better/satisfactory results in venous ulcer with area superior to 3.93 in². and the usage of Petrolatum® Gaze with elastic bandage in venous ulcer was inferior to 3.93 in².
5

Desenvolvimento de membranas à base de quitosana e de carboximetilcelulose para aplicação na área biomédica / Development of membranes based on chitosan and carboxymethylcellulose for use in biomedical area

Melin, Giovanna Rodrigues 23 August 2013 (has links)
A quitosana é um polissacarídeo produzido pela desacetilação da quitina e tem sido estudada para aplicação como biomaterial por apresentar características, tais como: biocompatibilidade, atoxidade e ação antimicrobiana. O objetivo deste estudo foi o desenvolvimento e caracterização química, física e biológica de membranas à base de quitosana (QUI) e carboximetilcelulose (CMC) para aplicação na área biomédica. Foram realizados ensaios de resistência, capacidade de absorção de água e perda de massa em solução salina de tampão fosfato (PBS) e saliva artificial, infravermelho por transformada de Fourier (FTIR), calorimetria exploratória diferencial (DSC), bioatividade, citoxicidade e degradação. Nos ensaios de citotoxidade, observou-se que as membranas desenvolvidas são atóxicas e nos ensaios de absorção de água que a carboximetilcelulose aumentou significamente a capacidade de absorção da membrana. As características naturais dos polímeros não foram alteradas, como observado no ensaio térmico (DSC) e no FTIR. Referente à liberação da lisozima, as membranas de QUI e QUI/CMC/QUI obtiveram melhores resultados, tanto na liberação quanto na atividade da enzima. As principais aplicações das membranas estudadas na área biomédica são como bandagens. / Chitosan is a polysaccharide produced from chitin by deacetylation and has been studied for application as biomaterial for presenting characteristics, such as biocompatibility and antimicrobial atoxidade. The objective of this study was the development and characterization chemical, physical and biological of membranes based on chitosan and carboxymethylcellulose (CMC) for application in the biomedical area. Tests of resistance, water absorption capacity and mass loss in phosphate buffered saline (PBS) and artificial saliva, Fourier transform infrared (FTIR), differential scanning calorimetry (DSC), bioactivity and cytotoxicity. The tests of cytotoxicity revealed that the membranes developed are non toxic and water absorption test the CMC increased significantly absorption capacity of membrane. The natural characteristics of the polymers were not changed, as observed on DSC and FTIR. With regard to the release of lysozyme, membranes CHI and CHI/CMC/CHI obtained better results in both the release and in the activity of the enzyme. The main applications of the membranes studied in the biomedical field are like bandages.
6

Efeito da bandagem Dynamic Tape™ na atividade eletromiográfica do músculo glúteo médio e no desempenho funcional do membro inferior em mulheres saudáveis: estudo controlado e randomizado

SILVA, Roberta de Oliveira e 08 July 2016 (has links)
A bandagem funcional Dynamic Tape™ consiste em um promissor instrumento de intervenção neuro-músculo-esquelética, de origem australiana, com princípios similares aos da Kinesio taping®, porém com propriedades mecânicas superiores. Poucos estudos dedicaram-se a avaliar os efeitos da bandagem funcional sobre a função do músculo glúteo médio, sendo que nenhum deles utilizou a bandagem funcional Dynamic Tape™. Deste modo, o objetivo do presente estudo foi avaliar o efeito da aplicação da bandagem funcional por Dynamic Tape™ na atividade eletromiográfica do músculo glúteo médio e sobre o desempenho funcional do membro inferior em testes de corrida e salto em mulheres saudáveis. Cinquenta e duas mulheres entre 18 e 30 anos, ativas, foram alocadas aleatoriamente em três grupos: aplicação da Dynamic Tape™ no glúteo médio – grupo bandagem (GB, n = 17), aplicação da Dynamic Tape™ na forma placebo no glúteo médio – grupo placebo (GP, n = 18) e sem qualquer intervenção – grupo controle (GC, n = 17). Após avaliação física e verificação de critérios de inclusão e exclusão, foi realizada a avaliação eletromiográfica do músculo glúteo médio do membro dominante em repouso, contração isométrica voluntária máxima, agachamento unipodal, aterrissagem da plataforma e salto da plataforma seguido de salto vertical máximo. Posteriormente, foi avaliado o desempenho funcional em três testes: shuttle run, triple hop test e six-meter timed hop test. A análise de variância com medidas repetidas não revelou diferenças significativas entre os grupos e entre os períodos de avaliação quanto a atividade eletromiográfica do músculo glúteo médio durante o repouso (GBpré 2,03±1,01, GBpós 2,01±0,88; GCpré 1,55±0,96, GCpós 1,29±0,81; GPpré 1,78±0,92, GPpós 1,36±0,75) durante o agachamento unipodal (GBpré 44,36±21,22, GBpós 40,28±16,18; GCpré 31,38±12,22, GCpós 34,74±19,90; GPpré 34,73±14,48, GPpós 29,43±11,01), durante a aterrissagem anterior da plataforma (GBpré 27,98±12,95, GBpós 30,20±14,19; GCpré 22,62±8,68, GCpós 22,93±11,88; GPpré 21,56±6,87, GPpós 26,05±13,89) e durante o salto anterior seguido do salto vertical máximo (GBpré 43,54±18,40, GBpós 47,98±18,68; GCpré 39,23±16,99, GCpós 63,34±63,77; GPpré 79,64±177,49, GPpós 35,42±14,81). Do mesmo modo, não foram encontradas diferenças significativas entre os grupos e os períodos de avaliação quanto aos testes sutlle run (GBpré 9,99±0,83, GBpós 9,94±0,65; GCpré 9,78±0,73, GCpós 10,19±0,66; GPpré 9,76±0,82, GPpós 9,63±0,53), triple hop test (GBpré 2,71±0,37, GBpós 2,74±0,32; GCpré 2,75±0,51, GCpós 2,56±0,50; GPpré 2,76±0,47, GPpós 2,76±0,39) e six-meter timed hop test (GBpré 3,34±0,55, GBpós 3,26±0,57; GCpré 3,47±0,57, GCpós 3,70±0,54; GPpré 3,18±0,59, GPpós 3,22±0,56).Portanto, conclui-se que seu uso não favorece a atividade eletromiográfica do músculo glúteo médio e o desempenho do membro inferior em testes de corrida e salto em mulheres saudáveis. / The Dynamic Tape ™ is a promising tool for neuro-musculoskeletal intervention of Australian origin, with similar principles as Kinesio taping®, but with superior mechanical properties. Few studies were dedicated to assess the effects of taping on the gluteus medius muscle function, and none of them used the taping Dynamic Tape ™. Thus, the aim of this study was to evaluate the effect of application of taping by Dynamic Tape ™ in electromyographic activity of the gluteus medius muscle and the functional performance of the lower limb in running tests and jump in healthy women. Fifty-two women between 18 and 30 years, active, were randomly allocated into three groups: Application Dynamic Tape ™ in the gluteus medius - banding group (GB, n = 17), application of Dynamic Tape ™ in placebo form the gluteus medius - placebo group (GP, n = 18) and without any intervention - control group (CG, n = 17). After physical assessment and verification of inclusion and exclusion criteria, the electromyographic evaluation of the gluteus medius muscle of the dominant limb at rest was performed maximal voluntary isometric contraction, squat, deck landing and jumping followed by maximum vertical jump platform. Subsequently, the functional performance in three tests were evaluated: shuttle run, triple hop test and six-meter timed hop test. Analysis of variance with repeated measures revealed no significant differences between groups and between the evaluation periods as the electromyographic activity of the gluteus medius muscle during rest (GBpré 2,03±1,01, GBpós 2,01±0,88; GCpré 1,55±0,96, GCpós 1,29±0,81; GPpré 1,78±0,92, GPpós 1,36±0,75) during the single leg squat task (GBpré 44,36±21,22, GBpós 40,28±16,18; GCpré 31,38±12,22, GCpós 34,74±19,90; GPpré 34,73±14,48, GPpós 29,43±11,01) the drop landing task (GBpré 27,98±12,95, GBpós 30,20±14,19; GCpré 22,62±8,68, GCpós 22,93±11,88; GPpré 21,56±6,87, GPpós 26,05±13,89) and during the jump landing + maximum vertical jump task (GBpré 43,54±18,40, GBpós 47,98±18,68; GCpré 39,23±16,99, GCpós 63,34±63,77; GPpré 79,64±177,49, GPpós 35,42±14,81). Similarly, there were no significant differences between groups and periods of assessment as to sutlle run tests (GBpré 9,99±0,83, GBpós 9,94±0,65; GCpré 9,78±0,73, GCpós 10,19±0,66; GPpré 9,76±0,82, GPpós 9,63±0,53), triple hop test (GBpré 2,71±0,37, GBpós 2,74±0,32; GCpré 2,75±0,51, GCpós 2,56±0,50; GPpré 2,76±0,47, GPpós 2,76±0,39) and six-meter timed hop test (GBpré 3,34±0,55, GBpós 3,26±0,57; GCpré 3,47±0,57, GCpós 3,70±0,54; GPpré 3,18±0,59, GPpós 3,22±0,56) .Therefore it follows that their use does not favor the electromyographic activity of the gluteus medius muscle and the performance of the lower limb in running tests and jump in healthy women. / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES
7

Desenvolvimento de membranas à base de quitosana e de carboximetilcelulose para aplicação na área biomédica / Development of membranes based on chitosan and carboxymethylcellulose for use in biomedical area

Giovanna Rodrigues Melin 23 August 2013 (has links)
A quitosana é um polissacarídeo produzido pela desacetilação da quitina e tem sido estudada para aplicação como biomaterial por apresentar características, tais como: biocompatibilidade, atoxidade e ação antimicrobiana. O objetivo deste estudo foi o desenvolvimento e caracterização química, física e biológica de membranas à base de quitosana (QUI) e carboximetilcelulose (CMC) para aplicação na área biomédica. Foram realizados ensaios de resistência, capacidade de absorção de água e perda de massa em solução salina de tampão fosfato (PBS) e saliva artificial, infravermelho por transformada de Fourier (FTIR), calorimetria exploratória diferencial (DSC), bioatividade, citoxicidade e degradação. Nos ensaios de citotoxidade, observou-se que as membranas desenvolvidas são atóxicas e nos ensaios de absorção de água que a carboximetilcelulose aumentou significamente a capacidade de absorção da membrana. As características naturais dos polímeros não foram alteradas, como observado no ensaio térmico (DSC) e no FTIR. Referente à liberação da lisozima, as membranas de QUI e QUI/CMC/QUI obtiveram melhores resultados, tanto na liberação quanto na atividade da enzima. As principais aplicações das membranas estudadas na área biomédica são como bandagens. / Chitosan is a polysaccharide produced from chitin by deacetylation and has been studied for application as biomaterial for presenting characteristics, such as biocompatibility and antimicrobial atoxidade. The objective of this study was the development and characterization chemical, physical and biological of membranes based on chitosan and carboxymethylcellulose (CMC) for application in the biomedical area. Tests of resistance, water absorption capacity and mass loss in phosphate buffered saline (PBS) and artificial saliva, Fourier transform infrared (FTIR), differential scanning calorimetry (DSC), bioactivity and cytotoxicity. The tests of cytotoxicity revealed that the membranes developed are non toxic and water absorption test the CMC increased significantly absorption capacity of membrane. The natural characteristics of the polymers were not changed, as observed on DSC and FTIR. With regard to the release of lysozyme, membranes CHI and CHI/CMC/CHI obtained better results in both the release and in the activity of the enzyme. The main applications of the membranes studied in the biomedical field are like bandages.
8

Ocorrência de infecção da corrente sanguínea relacionada ao cateter venoso central no paciente adulto crítico utilizando no sítio de saída o curativo gel de clorexidina ou filme transparente de poliuretano / Occurrence of catheter-related bloodstream infection in adult critical patients using chlorhexidine gel dressing or polyurethane transparent film at the catheter exit site

Vendrusculo, Tatiane Meda 19 December 2016 (has links)
Curativos gel de clorexidina (CGCHX) são uma tecnologia inovadora e com custo financeiro alto no que tange os cuidados do Cateter Venoso Central (CVC), são benéficos na prevenção das Infecções da Corrente Sanguínea Relacionadas ao Cateter (ICSRC). Tal curativo pode ser compreendido como uma recomendação do Programa Nacional de Segurança do Paciente, o qual prioriza a prevenção de infecções relacionadas à saúde. O presente estudo teve como objetivo identificar a ocorrência de ICSRC em paciente adulto crítico com CVC de curta duração que utilizou como cobertura no sítio de saída o CGCHX ou Filme Transparente de Poliuretano (FTP). Trata-se de um estudo de corte transversal prospectivo realizado no Centro de Terapia Intensiva e Unidade Coronariana de um hospital de ensino do interior do estado de São Paulo. A coleta de dados foi realizada pelo próprio pesquisador ou pelos auxiliares de pesquisa. No momento da retirada do cateter intravascular foram obtidas duas amostras de hemocultura e a ponta do cateter. A coleta de dados foi realizada no período de 1º de setembro a 31 de dezembro de 2014. A população do estudo foi constituída por 56 pacientes que tiveram um CVC e utilizaram o CGCHX ou FTP como cobertura do sítio de saída do CVC. Desses 56 pacientes, 11 foram excluídos, sendo seis devido a não ter sido coletado a ponta do cateter e cinco pela falta da coleta de hemocultura, sendo então a amostra final de 45 pacientes. Utilizaram-se CGCHX em 18 pacientes e o FTP em 27. Houve a presença de dois casos de ICSRC identificados no grupo de pacientes que utilizaram o FTP e os microrganismos isolados foram o Acinetobacter baumannii e Klebsiella pneumoniae. Diante dos resultados obtidos nesse estudo acredita-se que antes de incorporar novas tecnologias de alto custo deve-se implementar as medidas padrões para inserção e manutenção dos cateteres intravasculares com o objetivo de prevenir infecções relacionadas ao cateter / Chlorhexidine gel dressings (CGCHX) are an innovative technology with a high financial cost as it regards care related to central venous catheters (CVC), being beneficial in the prevention of catheter-related bloodstream infections (ICSRC). This dressing is a recommendation of the National Patient Safety Program, which prioritizes the prevention of health-related infection. The aim of the present study was to identify the occurrence of ICSRC in adult critical patients with a short-term CVC using CGCHX or polyurethane transparent film (FTP) at catheter the exit site. A prospective cross-sectional cohort study was conducted in the Coronary and Intensive Care Unit of a teaching hospital in the interior of the state of São Paulo. Data were collected by the researcher and by research assistants. At the time of removing the intravascular catheter, two blood culture samples and the catheter\'s tip were collected. Data collection took place between September 1st and December 31st , 2014. The study population was made up of 56 patients who had a CVC and used CGCHX or FTP as coverage for the CVC exit site. Of these 56 patients, 11 were excluded, six for not being possible to collect their catheter\'s tip and five due to the lack of a blood culture sample, thus the final sample consisted of 45 patients. Eighteen patients used CGCHX and 27 used FTP. There were two cases of ICSRC identified in the group of patients who used FTP and the microorganisms isolated were Acinetobacter baumannii and Klebsiella pneumoniae. In face of the results obtained in this study, it is believed that before incorporating new high cost technologies it is necessary to implement standard measures for insertion and maintenance of intravascular catheters, with the aim of preventing catheter-related infections
9

Ocorrência de infecção da corrente sanguínea relacionada ao cateter venoso central no paciente adulto crítico utilizando no sítio de saída o curativo gel de clorexidina ou filme transparente de poliuretano / Occurrence of catheter-related bloodstream infection in adult critical patients using chlorhexidine gel dressing or polyurethane transparent film at the catheter exit site

Tatiane Meda Vendrusculo 19 December 2016 (has links)
Curativos gel de clorexidina (CGCHX) são uma tecnologia inovadora e com custo financeiro alto no que tange os cuidados do Cateter Venoso Central (CVC), são benéficos na prevenção das Infecções da Corrente Sanguínea Relacionadas ao Cateter (ICSRC). Tal curativo pode ser compreendido como uma recomendação do Programa Nacional de Segurança do Paciente, o qual prioriza a prevenção de infecções relacionadas à saúde. O presente estudo teve como objetivo identificar a ocorrência de ICSRC em paciente adulto crítico com CVC de curta duração que utilizou como cobertura no sítio de saída o CGCHX ou Filme Transparente de Poliuretano (FTP). Trata-se de um estudo de corte transversal prospectivo realizado no Centro de Terapia Intensiva e Unidade Coronariana de um hospital de ensino do interior do estado de São Paulo. A coleta de dados foi realizada pelo próprio pesquisador ou pelos auxiliares de pesquisa. No momento da retirada do cateter intravascular foram obtidas duas amostras de hemocultura e a ponta do cateter. A coleta de dados foi realizada no período de 1º de setembro a 31 de dezembro de 2014. A população do estudo foi constituída por 56 pacientes que tiveram um CVC e utilizaram o CGCHX ou FTP como cobertura do sítio de saída do CVC. Desses 56 pacientes, 11 foram excluídos, sendo seis devido a não ter sido coletado a ponta do cateter e cinco pela falta da coleta de hemocultura, sendo então a amostra final de 45 pacientes. Utilizaram-se CGCHX em 18 pacientes e o FTP em 27. Houve a presença de dois casos de ICSRC identificados no grupo de pacientes que utilizaram o FTP e os microrganismos isolados foram o Acinetobacter baumannii e Klebsiella pneumoniae. Diante dos resultados obtidos nesse estudo acredita-se que antes de incorporar novas tecnologias de alto custo deve-se implementar as medidas padrões para inserção e manutenção dos cateteres intravasculares com o objetivo de prevenir infecções relacionadas ao cateter / Chlorhexidine gel dressings (CGCHX) are an innovative technology with a high financial cost as it regards care related to central venous catheters (CVC), being beneficial in the prevention of catheter-related bloodstream infections (ICSRC). This dressing is a recommendation of the National Patient Safety Program, which prioritizes the prevention of health-related infection. The aim of the present study was to identify the occurrence of ICSRC in adult critical patients with a short-term CVC using CGCHX or polyurethane transparent film (FTP) at catheter the exit site. A prospective cross-sectional cohort study was conducted in the Coronary and Intensive Care Unit of a teaching hospital in the interior of the state of São Paulo. Data were collected by the researcher and by research assistants. At the time of removing the intravascular catheter, two blood culture samples and the catheter\'s tip were collected. Data collection took place between September 1st and December 31st , 2014. The study population was made up of 56 patients who had a CVC and used CGCHX or FTP as coverage for the CVC exit site. Of these 56 patients, 11 were excluded, six for not being possible to collect their catheter\'s tip and five due to the lack of a blood culture sample, thus the final sample consisted of 45 patients. Eighteen patients used CGCHX and 27 used FTP. There were two cases of ICSRC identified in the group of patients who used FTP and the microorganisms isolated were Acinetobacter baumannii and Klebsiella pneumoniae. In face of the results obtained in this study, it is believed that before incorporating new high cost technologies it is necessary to implement standard measures for insertion and maintenance of intravascular catheters, with the aim of preventing catheter-related infections
10

Adesividade e irritação cutânea do filme transparente gel de clorexidina em pacientes submetidos ao transplante de células tronco hematopoiéticas / Adhesiveness and skin rash related to the transparent film dressing with chlorhexidine gel applied to patients submitted to hematopoietic stem cell transplantation

Santos, Bruna Nogueira dos 21 September 2015 (has links)
O Transplante de Células-Tronco Hematopoéticas (TCTH) trata-se da substituição das Células-Tronco Hematopoéticas (CTH) doentes de um indivíduo por CTH normais com o objetivo de normalizar a hematopoese do receptor. O cateter venoso central (CVC) tornou-se indispensável para viabilizar tal terapêutica pela segurança na infusão das CTH e dos quimioterápicos. Para o TCTH são utilizados cateteres do tipo Hickman ou duplo lúmen, ambos de longa permanência. O curativo adesivo utilizado no sítio de inserção do cateter é essencial para a fixação do cateter, proteção contra agentes externos e prevenção de infecção. Há forte evidência clínica no uso do filme transparente gel de clorexidina (CHX) como uma alternativa no controle de infecções relacionadas ao cateter. A adesividade deste curativo confere-lhe uma possível permanência de até sete dias aderido à pele, o que evita repetidas aplicações e remoções do curativo, diminui a frequência na manipulação do cateter, a ocorrência de infecção e irritação cutânea local. Observa-se que a adesividade do curativo nem sempre permite a permanência por sete dias, sendo necessárias trocas não planejadas, podendo causar lesões à integridade cutânea. Neste estudo, objetivou-se avaliar a adesividade e a irritação cutânea do filme transparente gel de CHX aplicado no sítio de inserção do CVC por meio de um estudo transversal, prospectivo, realizado em um hospital público de ensino, no período de novembro de 2013 a junho de 2014, com crianças e adultos de ambos os sexos com doenças autoimunes ou onco-hematológicas submetidos ao TCTH. A amostra desta pesquisa foi constituída por 25 pacientes. Onze (44%) apresentaram irritação cutânea caracterizada por perda de pele de extensão <=0,5cm, perda de pele de extensão > 0,5cm, placa eritematosa e vesículas. Destes, seis tiveram necessidade de suspensão do uso do curativo. A pele fragilizada devido ao uso de agentes quimioterápicos pode aderir fortemente ao curativo adesivo, sendo desprendida com o mesmo quando este é removido. A perda da integridade cutânea com remoção da camada protetora da pele facilita a entrada de microrganismos aumentando a susceptibilidade a infecções em pacientes imunossuprimidos. Em 55,6% das avaliações foi observado desprendimento do curativo e a região da fenda foi onde mais ocorreu desprendimento (43,4%). Esta é uma região da margem do curativo, assim denominada por possuir uma abertura no adesivo onde são posicionadas as vias do cateter. Infere-se que devido à mobilidade do paciente e manuseio das vias do cateter, com o passar dos dias, essa região da borda do curativo apresenta maior desprendimento. Em 8,4% das observações havia bolha de ar no gel de clorexidina envolvendo o sítio de inserção do cateter. A bolha de ar no gel de clorexidina significa que este não está em contato com a pele do paciente o que é preocupante quando envolve o sítio de inserção do cateter, pois a CHX não está exercendo sua função antisséptica neste local, onde há possibilidade de migração extra- lúmen de microrganismos à corrente sanguínea / Hematopoietic stem cell transplantation (HSCT) involves the replacement of sick hematopoietic stem cells (HSC) from an individual with normal HSC, with the aim to restore the recipient\'s hematopoiesis. Central venous catheters (CVC) have become indispensable to make this therapy feasible due to the safety of infusion of the HSC and the chemotherapeutic agents. In HSCT, long-term Hickman or long-term double lumen catheters are used. The adhesive dressing used in the site of insertion of the catheter is essential for the catheter fixation, protection against external agents and prevention of infection. There is strong clinical evidence on the use of transparent film dressing with chlorhexidine gel (CHX) as an alternative in the control of catheter-related infections. The adhesiveness of this dressing allows it to be used up to seven days once it adheres to the skin, which avoids repeated dressing applications and removals, and reduces the frequency of catheter handling, the occurrence of infection, and local skin rash. However, as observed, the dressing adhesiveness does not always allow it to be used for seven days, and unplanned replacements may be needed, which can cause lesions to the skin integrity. The objective of this study was to evaluate the adhesiveness and skin rash related to the transparent film dressing with CHX gel applied at the site of insertion of the CVC by means of a cross-sectional, prospective study developed at a public teaching hospital, between November 2013 and June 2014, with children and adults of both genders with autoimmune or onco-hematological diseases who were submitted to HSCT. The sample comprised 25 patients. Eleven (44%) presented skin rash characterized by skin loss to an extension of <=0.5 cm, skin loss to an extension of > 0.5 cm, erythematous plaque and vesicles. Of these, six had to interrupt the use of the dressing. Frail skin due to the use of chemotherapeutic agents can adhere strongly to the adhesive dressing, coming off with the dressing at its removal. The loss of skin integrity with the removal of the skin\'s protective layer facilitates the entrance of microorganisms, increasing susceptibility to infections in immunosuppressed patients. In 55.6% of the evaluations, there was dressing detachment, and it was greater in the opening region (43.4%), which is a region in the dressing border with a break in the adhesive where the catheter is placed. Given the mobility of the patient and the handling of the catheter, over the days, this region of the dressing border presents greater detachment. In 8.4% of the observations there were air bubbles in the chlorhexidine gel involving the site of insertion of the catheter. Air bubbles in the chlorhexidine gel means that it is not in contact with the patient\'s skin, which is a cause of concern when the site of insertion of a catheter is involved, since CHX is not exerting its antiseptic function in this location, which can lead to extra-lumen migration of microorganisms to the bloodstream

Page generated in 0.063 seconds