• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Caracterização espectroscópica, microscópica e eletroquímica de eletrodos modificados com diferentes nanotubos de carbono para a detecção de catecol e dopamina

Lima, Ana Paula de 16 February 2017 (has links)
Os nanotubos de carbono (CNTs) possuem várias aplicações devido às suas propriedades com destaque à alta resistência química, baixa densidade e elevada condutividade elétrica. Dentro da Química Analítica, destacam-se as propriedades eletrocatalíticas destes nanomateriais para a modificação da superfície de eletrodos de trabalho, e assim atuarem como sensores eletroquímicos. Este trabalho investiga a utilização de três tipos de CNTs, um de paredes simples (SWCNT) e dois de paredes duplas (DWCNT), sendo um destes de menor comprimento (S-DWCNT), para a modificação do eletrodo de carbono vítreo (GCE). Inicialmente, a caracterização dos CNTs não funcionalizados e funcionalizados foi realizada com o intuito principal de analisar as possíveis mudanças obtidas pelo processo de funcionalização. As caracterizações foram feitas através de espectroscopia na região do infravermelho (IR) e espectroscopia Raman. As morfologias destes materiais foram avaliadas por microscopia eletrônica de varredura (SEM). A estabilidade térmica foi observada pela análise termogravimétrica. Posteriormente à etapa de caracterização dos CNTs, investigou-se o comportamento eletroquímico dos compostos fenólicos catecol (CT) e dopamina (DP) em eletrodos modificados com os três diferentes CNTs. O estudo do pH do eletrólito indicou melhores resultados em termos de corrente com a solução de HClO4. O estudo da velocidade de varredura de voltamogramas cíclicos indicou que os processos de oxidação eletroquímica são controlados ora por difusão das espécies ao eletrodo ora por processos adsortivos. A detecção amperométrica das espécies em sistema de análise por injeção em batelada (BIA) foi avaliada utilizando eletrodos modificados com os três CNTs. Obtiveram-se amplas faixas lineares de 1-1000 μmol L- 1 tanto para CT como para DP, em todos os casos. Para CT e DP, baixos desvios padrão foram obtidos para injeções consecutivas (n=15) de aproximadamente 1,0% para GCE, SWCNT, DWCNT e S-DWCNT. Frequências analíticas de 135 h-1 foram obtidas empregando-se os eletrodos modificados, enquanto que em GCE obteve-se 105 h-1. Baixos limites de detecção para CT (0,0093; 0,0136; 0,0715 μmol L-1) e DP (0,0145; 0,0493; 0,1743 μmol L-1) foram obtidos em SWCNT, DWCNT e S-DWCNT, respectivamente, enquanto que em GCE foram obtidos 0,867 e 1,034 para CT e DP, respectivamente. Todos resultados obtidos mostraram-se promissores, com faixas lineares amplas e DLs baixos, manifestando assim que as modificações em GCE com os CNTs foram eficientes e resultaram em sensores eletroquímicos mais sensíveis para os analitos investigados. / Carbon nanotubes (CNTs) have various applications due to their properties with emphasis to high chemical resistance, low density and high electrical conductivity. Within Analytical Chemistry, the electrocatalytic properties of these nanomaterials are highlighted towards the the surface modification of working electrodes, and thus act as electrochemical sensors. This work investigates the use of three types of CNTs, a single-walled (SWCNT) and two double walled carbon nanotubes (DWCNT), one of these of smaller length (S-DWCNT), for the modification of a glassy carbon electrode (GCE). Initially, the functionalized and non-functionalized CNTs were characterized aiming to analyze the possible changes obtained by functionalization process. The characterizations were made through infrared (IR) and Raman spectroscopies. The morphologies of these materials were evaluated by scanning electron microscopy (SEM). The thermal stability was observed by thermogravimetric analysis. After the step of characterizing the CNTs, it was investigated the electrochemical behavior of the phenolic compounds catechol (CT) and dopamine (DP) on electrodes modified with three different CNTs. The study of pH of the electrolyte showed best results in terms of current for HClO4 solution. Study of cyclic voltammetry scan rate indicated that the electrochemical oxidation processes are controlled either by diffusion of the species to the electrode or by adsorptive processes. The amperometric detection analysis of the species using a batch injection system (BIA) was carried out using three CNTs modified electrodes. It was obtained wide linear ranges of 1-1000 μmol L- 1 for both CT and DP in all cases. For CT and DP, low standard deviations were obtained for consecutive injections (n = 15) of approximately 1.0% on GCE, SWCNT, DWCNT and S-DWCNT. Analytical frequencies of 135 h-1 were obtained employing the modified electrodes, while in GCE was obtained 105 h-1. Low detection limits for CT (0.0093; 0.0136; 0.0715 μmol L-1) and DP (0.0145; 0.0493; 0.1743 μmol L-1) were obtained in SWCNT, DWCNT and S-DWCNT, respectively, while in GCE 0.867 and 1.034 μmol L-1 were obtained for CT and DP, respectively. All results proved to be promising, with wide linear ranges and low DLs, thus manifesting that the modifications of GCE with CNTs were efficient and resulted in more sensitive electrochemical sensors for the analytes investigated. / Dissertação (Mestrado)
2

Desenvolvimento de métodos eletroanalíticos empregando análise por injeção em batelada para a determinação de nafazolina, zinco, feniramina e clorfeniramina em formulações farmacêuticas

Oliveira, Thiago da Costa 24 July 2015 (has links)
Fundação de Amparo a Pesquisa do Estado de Minas Gerais / In this work we investigated the potentiality of batch injection analysis with square-wave voltammetry (BIA-SWV) detection for simultaneous determination of Zn and naphazoline (NAF) and batch injection analysis with multiple pulse amperometric (BIA-MPA) detection for simultaneous determination of NAF and pheniramine (FEN) or NAF and chlorpheniramine (CLO). In both methods, boron-doped diamond (BDD) was used as working electrode. For the simultaneous determination of Zn and NAF by BIA-SWV, the following conditions have been optimized: supporting electrolyte: acetate buffer 0.05 mol L-1 (pH = 4.7), injection volume: 100 μL, deposition time (Zn): 5 s, deposition potential (Zn) -1.5 V, : 100 s-1, a: 60 mV, ΔEs: 6 mV. Under these conditions, the method showed linear response range between 10 and 60 μmol L-1 for Zn (r = 0.992) and between 3.0 e 21 μmol L-1 for NAF (r = 0.999), high analytical frequency (70 injections h-1) and LOD of 0.126 μmol L-1 and 0.04 μmol L-1 for Zn and NAF, respectively. In the study of repeatability (n = 20), the calculated RSD were 0.98% and 0.97% for Zn and NAF, respectively. The simultaneous determination of NAF and FEN or NAF and CLO by BIA-MPA was performed with the application of three sequential pulses in function of time to the BDD electrode using Britton-Robinson Buffer solution 0.12 mol L-1 (pH = 10.0) as supporting electrolyte. At +1.1 V/50 ms, FEN or CLO was detected (oxidation) without interference of NAF. At +1.3 V/50 ms, both compounds (FEN + NAF or CLO + NAF) were oxidized. The current of NAF can then be obtained by subtraction of the currents detected during application of both potential pulses using a correction factor. The proposed method presented good ability (RSD = 1.7 and 4.0% for FEN and NAF; 2.1% and 3.6% for CLO and NAF, respectively; n=20); high analytical frequency (110 injections h-1), linear concentration range between 16 e 100 μmol L-1 for FEN and CLO (r > 0.996) and between 2 e 15 μmol L-1 for NAF (r > 0.997). The LOD calculated were 0.367, 0.361 e 0.148 μmol L-1, for FEN, CLO and NAF, respectively. The proposed methods were used for determination of these compounds in pharmaceutical samples. The obtained results were statistically similar to that obtained by HPLC (NAF, FEN and CLO) and atomic spectroscopy (Zn). / No presente trabalho investigou-se a potencialidade do sistema de análise por injeção em batelada com detecção por voltametria de onda quadrada (BIA-SWV) para determinação simultânea de Zn e nafazolina (NAF) e do sistema análise por injeção em batelada com detecção por amperometria de múltiplos pulsos (BIA-MPA) para determinação simultânea de NAF e feniramina (FEN) ou NAF e clorfeniramina (CLO). Em ambos os métodos, diamante dopado com boro (BDD) foi usado como eletrodo de trabalho. Para determinação simultânea de Zn e NAF empregando BIA-SWV, as seguintes condições foram otimizadas: eletrólito de suporte: tampão acetato 0,05 mol L-1 (pH = 4,7), volume de injeção: 100 μL, tempo de deposição (Zn): 5 s, potencial de deposição (Zn): -1,5 V, : 100 s-1, a: 60 mV, ΔEs: 6 mV. Nestas condições, o método apresentou faixa linear de resposta entre 10 e 60 μmol L-1 para Zn (r = 0,992) e entre 3,0 e 21 μmol L-1 para NAF (r = 0,999), frequência analítica de 70 injeções h-1 e limites de detecção de 0,126 μmol L-1e 0,04 μmol L-1 para Zn e NAF, respectivamente. No estudo de repetibilidade (n = 20), os DPRs foram calculados 0,98% e 0,97% para Zn e NAF, respectivamente. A determinação simultânea de NAF e FEN ou NAF e CLO por BIA-MPA foi realizada através da aplicação de dois pulsos de potenciais em função do tempo ao eletrodo de BDD usando tampão BR 0,12 mol L-1 (pH = 10) como eletrólito suporte. Em +1,1 V/50 ms, FEN ou CLO foram oxidadas livre da interferência de NAF. Em +1,3 V/50ms, ambos os compostos (NAF + FEN ou NAF + CLO) foram oxidados. A corrente proveniente da oxidação da NAF foi obtida pela subtração entre as correntes detectadas em ambos os pulsos de potenciais com auxílio de um fator de correção (FC). O método proposto apresentou boa estabilidade (DPR = 1,7 e 3,95% para FEN e NAF; 2,1 e 3,6% para CLO e NAF, respectivamente; n=20), alta frequência analítica (110 injeções h-1), faixa linear de resposta entre 16 e 100 μmol L-1 para FEN e CLO (r > 0,996) e entre 2 e 15 μmol L-1 para NAF (r > 0,997). Os limites de detecção foram de 0,367, 0,361 e 0,148 μmol L-1 para FEN, CLO e NAF, respectivamente. Os métodos propostos foram usados na determinação destes compostos em formulações farmacêuticas. Os resultados obtidos com os métodos propostos foram estatisticamente similares aos obtidos por HPLC (NAF, FEN e CLO) ou absorção atômica (Zn). / Mestre em Química

Page generated in 0.0914 seconds