• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 209
  • 175
  • 39
  • 24
  • 23
  • 16
  • 12
  • 9
  • 4
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 583
  • 128
  • 85
  • 82
  • 78
  • 63
  • 61
  • 59
  • 54
  • 50
  • 49
  • 48
  • 46
  • 46
  • 45
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
541

Preparation and Properties of Bio-Based Polyurethane Foam Prepared from Modified Natural Rubber and Poly(ε-caprolactone) / Préparation et Caractérisation des propriétés de mousses polyuréthane biobasées synthétisées à partir du caoutchouc naturel modifié et de la poly(ε-caprolactone)

Rattanapan, Suwat 27 June 2016 (has links)
L’objectif de ces travaux de recherche était de synthétiser de mousses polyuréthane (PUF) bio-basées à partir d’oligomères hydroxytéléchéliques issus du caoutchouc naturel (HTNR) ou à partir de poudrettes de pneus usagés (HTWT) et du diol de la polycaprolactone (PCL) comme segments soft. Les paramètres étudiés ont été le type de polyol et le rapport molaire entre HTNR/PCL et HTWT/PCL. La masse molaire de HTNR, HTWT et PCL étaient respectivement 1,800, 1400 et 2000 g/mol. L’effet du rapport molaire HTNR/PCL et HTWT/PCL (1/0, 1/0/5/, 1/1, et 0.5/1) sur la vitesse de formation des mousses et sur les propriétés chimiques et physiques a été étudié. Les structures chimiques de HTNR, HTWT et PUF ont été confirmées par FTIR et 1H-RMN. Le diol de la PCL était le plus réactif donc augmentant le contenu de PCL-diol la vitesse de formation des mousses a augmenté. La densité des mousses a changé légèrement avec le rapport molaire cependant la résistance à la traction reste dans la même gamme. Le diamètre moyen des cellules a augmenté en fonction du contenu de PCL-diol et la tendance inverse a été observée pour l’allongement à la rupture et la résistance à la compression. L’observation au microscope électronique à balayage (MEB) a montré que les mousses basées sur les HTNR étaient alvéolées et fermées. La biodégradabilité a été évaluée selon le test de Sturm. Polyéthylène à baisse densité et benzoate de sodium ont été utilisés respectivement comme témoins négatif et positif. Les mousses ont montré une période d’induction de 33 jours dans lequel le pourcentage de dégradation était ~ 7-10%. La biodégradation de PUF contenant seulement HTNR a été 8.4% après 28 jours et 31.89% après 60 jours ; les PUF contenants 1/0.5 HTNR/PCL ont montré un pourcentage supérieure : 11.31% après 28 jours et 45.6% après 60 jours. Le rapport molaire HTWT/PCL a influencé beaucoup la vitesse de formation des mousses et leur morphologie. Cellules fermées de forme polyédrique ont été observé par microscopie électronique à balayage. Les résultats de l’analyse thermogravimétrique ont montré que l’addition du diol de la PCL a augmenté la température de dégradation. Il a été observé qu’une basse vitesse de réaction génère des mousses à haute densité, petit diamètre de cellule et haute distribution des diamètres. La biodégradation des PUF contenant seulement HTWT a été 31.2% après 28 jours et 51.3% après 60 jours, tandis que les PUF contenant 1/0.5 HTWT/PCL ont montré une dégradation plus élevée : 39.1% après 28 jours et 64.3% après 60 jours. La vitesse de formation des mousses basées sur les HTWT était supérieure à celle des mousses basées sur les HTNR. Toutes les mousses basées sur les HTWT ont une densité supérieure et une taille de cellule inférieure à celles basées sur HTNR. La structure des cellules des mousses basées sur les HTNR ou HTWT était différente cependant toutes les mousses ont montré des cellules quasi complètement fermées. Les mousses basées sur les HTWT ont montré des propriétés thermiques et de biodégradation meilleures par rapport aux mousses basées sur les HTNR. / The aim of this research was to prepare a bio-based polyurethane foam (PUF) containing hydroxyl telechelic oligomers from natural rubber (HTNR) and waste tire crumbs (HTWT) and polycaprolactone diol (PCL) as soft segments. The studied parameters included type of polyols and molar ratio between HTNR/PCL and HTWT/PCL. The molecular weight of HTNR and HTWT derived from 1H-NMR spectra were 1,800 and 1,400 g/mol, respectively. The molecular weight of PCL diol was 2000 g/mol. The effect of HTNR/PCL and HTWT/PCL molar ratio (1/0, 1/0.5, 1/1 and 0.5/1) on the foam formation rate and physical and chemical properties of the resulting PUF was investigated. The chemical structure of HTNR, HTWT and PUF were confirmed by FTIR and 1H-NMR. PCL diol provided faster reaction, thus higher PCL diol content showed higher foam formation rate. The foam density slightly changed with the molar ratio whereas the specific tensile strength of all samples was in the same range. The average diameter of cell increased with increasing contents of PCL diol. The addition of PCL diol resulted in reduced elongation at break and compressive strength. The cellular structure observed by SEM micrographs of HTNR based foams showed an almost closed cell. The biodegradability was assessed according to a modified Sturm test. Low density polyethylene and sodium benzoate were used as a negative and positive control sample, respectively. PUF samples showed an induction time of 33 days in which the percentage of biodegradation was  7-11%. The biodegradation of PUF containing only HTNR was 8.4% and 31.89% at 28 days and 60 days of testing respectively whereas the PUF containing 1/0.5 HTNR/PCL (by mole) showed a higher biodegradation: 11.31% and 45.6% at 28 days and 60 days of testing respectively. The molar ratio of HTWT/PCL strongly affected the kinetic rate of foam formation and foam morphology. According to SEM micrographs, polyhedral closed cells were observed. The addition of the PCL diol increased the thermal degradation temperature of the PUF based on TGA results. A low kinetic rate provided PUF with a high density, small cell size and a broad cell size distribution. The biodegradation of PUF containing only HTWT was 31.2% and 51.3% at 28 days and 60 days of testing respectively whereas the PUF containing 1/0.5 HTWT/PCL diols (by mole) showed a higher biodegradation: 39.1% and 64.3% at 28 days and 60 days of testing respectively. The foam formation rate of HTWT based PUF was higher than the one of HTNR based PUF. All HTWT based PUF have a higher density than HTNR based PUF. The HTWT based PUF had an inferior cell size in comparison to HTNR based PUF. The cellular structure of HTNR based and HTWT based PUF were different, but all PUFs showed almost closed cells. The HTWT based PUF had a higher thermal degradation temperature and biodegradation properties than foams from HTNR. / วัตถุประสงค์ของงานวิจัยนี้ เพื่อทำการเตรียมโฟมพอลิยูรีเทนชีวภาพ (PUF) จากยางธรรมชาติดัดแปรที่มีหมู่ปลายไฮดรอกซิล (HTNR) ยางคลัมบ์ดัดแปรที่มีหมู่ปลาย ไฮดรอกซิล (HTWT) และพอลิคาโปรแลคโทน (PCL) ศึกษาผลของชนิดพอลิออล และสัดส่วนโดยโมลระหว่าง HTNR/PCL และ HTWT/PCL ที่สัดส่วน 1/0, 1/0.5, 1/1 และ 0.5/1 โดยโมล นํ้าหนักโมเลกุลของ HTNR, HTWT และ PCL ที่ใช้สำหรับงานวิจัยนี้ คำนวณจาก 1H-NMR คือ 1,800, 1,400 และ 2,000 g/mol ตามลำดับ ลักษณะโครงสร้างทางเคมีของ HTNR, HTWT และPUF สามารถวิเคราะห์และยืนยันด้วยเทคนิค FTIR และ 1H-NMR รวมถึงทำการวัดอัตราการก่อโฟม (Foam formation rate) ทดสอบสมบัติทางกายภาพ ทางเคมี และสมบัติการย่อยสลายทางชีวภาพ พบว่าในกรณีของโฟมพอลิยูรีเทนจาก HTNR/PCL เมื่อใช้ PCL ในปริมาณที่มากขึ้นจะส่งผลให้อัตราการก่อโฟมเร็วขึ้น และขนาดของเซลโฟมมีขนาดใหญ่ขึ้นด้วย ในขณะที่ค่าความหนาแน่น และความต้านทานต่อแรงดึงจำเพาะมีการเปลี่ยนแปลงเล็กน้อย การเติม PCL ในส่วนผสมของโฟมยังส่งผลให้ความสามารถในการยืด ณ จุดขาด และความทนทานต่อการกดมีค่าลดลง การคืนตัวหลังการกดของโฟม PUF2 (สัดส่วนระหว่าง HTNR/PCL = 1/0.5) จะให้ค่าตํ่าที่สุดคือ 40% ลักษณะของโฟมที่ได้จากการทดลองนี้โดยส่วนใหญ่จะเป็นแบบเซลปิด ความสามารถในการย่อยสลายทางชีวภาพของโฟม ทดสอบโดยใช้วิธี Sturm Test มี LDPE เป็นตัวเปรียบเทียบเชิงลบ และใช้ Sodium benzoate เป็นตัวเปรียบเทียบเชิงบวก พบว่าโฟมเริ่มมีการย่อยสายเกิดขึ้นอย่างเห็นได้ชัดที่เวลา 33 วัน มีเปอร์เซ็นต์การย่อยสลายในช่วง 7-11 เปอร์เซ็นต์ เปอร์เซ็นต์การย่อยสลายของโฟมจาก HTNR (PUF1) อยู่ที่ระดับ 8.4 และ 31.89 เปอร์เซ็นต์ และเปอร์เซ็นต์การย่อยสลายของโฟมจาก HTNR/PCL (1/0.5) อยู่ที่ระดับ 11.31 และ 45.6 เปอร์เซ็นต์ ที่เวลาในการทดสอบ 28 และ 60 วัน ตามลำดับ กรณีของโฟมพอลิยูรีเทนจาก HTWT/PCL เมื่อใช้ PCL ในปริมาณที่มากขึ้นจะส่งผลให้ค่าความหนาแน่นสูงขึ้น ขนาดของเซลโฟมลดลงมีการกระจายของเซลในวงกว้างไม่สมํ่าเสมอ เปอร์เซ็นต์การย่อยสลายทางชีวภาพของโฟมจาก HTWT (PUF5) อยู่ที่ระดับ 31.2 และ 51.3 เปอร์เซ็นต์ และเปอร์เซ็นต์การย่อยสลายของโฟมจาก HTWT/PCL (1/0.5) อยู่ที่ระดับ 39.1 และ 64.3 เปอร์เซ็นต์ ที่เวลาในการทดสอบ 28 และ 60 วัน ตามลำดับ เมื่อทำการเปรียบเทียบโฟมที่ได้จากการเตรียมโดยใช้พอลิออลหลักเป็น HTNR และ HTWT พบว่าโฟมจากพอลิออลหลัก HTWT ให้อัตราการก่อตัวของโฟมเร็วกว่า ขนาดของเซลโฟมเล็กกว่า ความหนาแน่น ความต้านทานต่อความร้อน และเปอร์เซ็นต์การย่อยสลายทางชีวภาพสูงกว่า เมื่อเทียบกับโฟมจากพอลิออลหลัก HTNR
542

Využití škrobu a glycerinu k přípravě polymerních fólií s řízenou dobou života / Use of starch and glycerin in polymer films with controlled life span

Almásyová, Zuzana January 2018 (has links)
This diploma thesis deals with preparation and testing of biodegradable materials for use in the packaging indrustry. The task of this work is to prepare set of laboratory made films based on wheat starch, glycerol, polyvinyl alcohol with the addition of a suitable additive, which has been selected as citric acid. A suitable composition meeting the requirements of the packaging foils has been found. Quaternary blends from all components achieve the best results. It has been found that citric acid can influence the chemical structure and thus affect the mechanical and thermal properities and also the degree of solubility. The films were characterized in terms of mechanical properities by tensile testing and thermal stability by means of thermogravimetric analysis with respect to the phase structure. The structure was characterized by Fourier transform infrared spectroscopy and confocal laser scanning microscopy. The biodegradability of the film was tested by its solubility in aqueous medium.
543

Modifikace termocitlivého kopolymeru bioaktivními látkami pro medicínské aplikace / Modification of thermosensitive copolymer with bioactive substances for medical applications

Debnárová, Simona January 2018 (has links)
Biodegradabilné syntetické polyméry nesú vlastnosti, ktoré ich zvýhodňujú oproti iným materiálom používaným na poli regeneratívnej medicíny a tkanivového inžinierstva. Najdôležitejšie výhody zahŕňajú schopnosť prispôsobovať mechanické a chemické vlastnosti aj kinetiku degradácie. Obzvlášť polyestery sú zaujímavé z pohľadu na ich biodegradáciu. Podliehajú hydrolýze, počas ktorej dochádza k štiepeniu esterových väzieb a degradačné produkty sú metabolizované bez akýchkoľvek škodlivých účinkov. Diplomová práca je zameraná na syntetické biodegradabilné triblokové kopolyméry PLGA-PEG-PLGA s obsahom kyseliny polymliečnej (PLA), kyseliny polyglykolovej (PGA) a polyetylénglykolu (PEG), ktoré patria do skupiny biodegradabilných polyesterov. Obsah hydrofilnej a hydrofóbnej zložky polymérneho reťazca spôsobuje amfifilný charakter kopolyméru. Pripravené triblokové kopolyméry sú schopné tvoriť hydrogél pomocou fyzikálneho sieťovania v dôsledku ich amfifilného charakteru. Tieto materiály zaznamenali významný záujem vo vedeckej oblasti. Teoretická časť diplomovej práce všeobecne popisuje hydrogély, bližšie sa venuje fyzikálnemu sieťovaniu amfifilných blokových kopolymérov a mechanizmom degradácie. Podrobný popis triblokového kopolyméru PLGA-PEG-PLGA je rozdelený na PLGA kopolyméry, PEG a ich fyzikálno-chemické vlastnosti. Zahrnuté sú aj poznatky o chemickej funkcionalizácii anhydridom kyseliny jantárovej, anhydridom kyseliny itakonovej a kyselinou listovou. Dopamín je prezentovaný ako spájací faktor a spomenuté sú taktiež najdôležitejšie bioaktívne látky. Experimentálna časť sa zaoberá konkrétnymi metódami syntézy, ktoré viedli k funkcionalizácii a modifikácii triblokových kopolymérov PLGA-PEG-PLGA. Funkcionalizáciou anhydridom kyseliny itakonovej bol získaný kopolymér s oboma koncami obohatenými o reaktívne dvojité väzby a karboxylové funkčné skupiny. Dvojité väzby umožňujú chemické sieťovanie a koncové karboxylové skupiny ponúkajú možnosť modifikácie kopolyméru biologicky aktívnymi látkami. Modifikácia bioaktívnymi látkami L-lyzínom a butylamínom obohacuje polymérnu sieť a dopamín v roli spojovacieho faktoru poskytuje univerzálnosť v naväzovaní bioaktívnych látok, stabilizuje ich a zabezpečuje zachovanie biologickej aktivity naviazaných bioaktívnych látok predĺžením reťazca. Výsledné produkty boli charakterizované pomocou 1H NMR, FTIR a DRA analýz. Funkcionalizácia anhydridom kyseliny itakonovej bola prevádzaná v tavenine. Podarilo sa dosiahnuť vyššieho množstva naviazanej kyseliny itakovovej s hodnotou 79,4 mol % a následné modifikácie boli prevádzané vo vodnom roztoku, organickom roztoku a taktiež v tavenine. Bolo zistené, že najefektívnejšia metóda modifikácie bola syntéza v organickom roztoku s rozpúšťadlom N,N-dimetylformamidom a aktivačným systémom dicyklohexylkarbodiimid/4-(dimetylamino)pyridínom. Najvyššie množstvo naviazaného dopamínu bolo 18,6 mol %, najvyššie množstvo naviazaného butylamínu bolo 7,8 mol % a L-lyzín sa naviazať nepodarilo.
544

Optimalizace odpadového hospodářství farmaceutické firmy / Optimization of waste management system in pharmaceutical company

Krystýnová, Hana January 2012 (has links)
The diploma thesis with the title Optimization of waste management system in pharmaceutical company first deal with basic concepts and requirements for originator of waste form the point of waste origin. The analysis of waste management of pharmaceutical company that manufactures generic drugs follows. Another aim of diploma thesis is suggested the possibilities how to optimize already existing waste management regard to environmental protection.
545

Diagnostika perspektivních elektroizolačních kapalin / Diagnostics of the perspective insulating liquids

Spohner, Milan January 2011 (has links)
This work deals with the classification and diagnosis of electrical insulating liquids. Furthermore, the theoretical part describes the mathematical and physical principles of these liquids. The automated workplace was compiled with development environment VEE Pro for measurement of viskosity and control thermostat medingen and modifiable components for measuring complex permittivity in the frequency range. In the experimental part was carried out measurements of selected material parameters, investigated the effect of difficult conditions and made the mathematical evaluation of physical phenomena.
546

Biodegradabilní kostní implantáty na bázi železa / Biodegradable bone implants based on iron

Müller, Petr January 2014 (has links)
The present work deals with the comparison of the properties of metallic biomaterials in terms of their suitability for use as a temporary metal implant. In the work is judged biocompatibility of materials, they are comparing the corrosion rates and the influence of additives in the iron alloy to change biocompatibility and corrosion rate. In a part of this work is suggesting a method of preparing biodegradable metallic samples with different alloying elements and determine the methods, processes and measuring the corrosion rates. Part of this work is the chapter dealing with the function and effect of iron in the human body and any complications that may occur when a surplus caused by the release of part of the implant during its degradation or corrosion products. The outcome of this work is sort of created an iron-based samples in terms of their electrochemical corrosion potential, corrosion rate of samples exposed in various corrosive solutions, spectroscopic elemental analysis and outputs from the microscopic observation of the structures.
547

Syntéza a charakterizace multifunkcionalizovaných biodegradabilních kopolymerů / Synthesis and Characterization of Multifunctionalized Biodegradable Copolymers

Michlovská, Lenka January 2014 (has links)
Předložená disertační práce shrnuje současné poznatky v oblasti termosenzitivních biodegradabilních kopolymerů, které ve formě vodného solu gelují při teplotě lidského těla. Tyto polymerní materiály jsou použitelné v medicíně pro injekční aplikace jako nosiče léčiv či resorbovatelné implantáty pro regeneraci tkání. V experimentální práci byly pomocí vakuové linky syntetizovány termosenzitivní amfifilní triblokové kopolymery na bázi biodegradabilního hydrofobního polylaktidu a polyglykolidu a biokompatibilního hydrofilního polyethylenglykolu (PLGA–PEG–PLGA). Připravený PLGA–PEG–PLGA kopolymer se dvěma fázovými přechody sol-gel a gel-suspenze byl následně modifikován anhydridem kyseliny itakonové. Výsledný funkcionalizovaný ITA/PLGA–PEG–PLGA/ITA kopolymer obsahuje na koncích řetězců reaktivní dvojné vazby vhodné k další polymeraci či síťování a karboxylové skupiny pro případné modifikace biologicky aktivními látkami. Fyzikální i chemické síťování bylo dále sledováno jak z hlediska poměrů hydrofilního a hydrofobního řetězce, tak i z hlediska množství navázané kyseliny itakonové. Vodné roztoky syntetizovaného ITA/PLGA–PEG–PLGA/ITA kopolymeru gelují v rozmezí teplot 33 - 43 °C. Kritická gelační koncentrace byla 6 % a kritická gelační teplota 34 °C pro kopolymer s poměrem PLGA/PEG = 2,5. Čím je kopolymer více hydrofobní, tím geluje dříve a je více hydrolyticky stabilní. Tuhost gelu stoupá se zvyšujícím se poměrem PLGA/PEG a je závislá na typu rozpouštědla použitého při přečišťování kopolymeru. Připravené ITA/PLGA–PEG–PLGA/ITA makomonomerů byly síťovány pomocí modrého světla bez dalšího síťovadla. Hydrolytická stabilita vzorků modifikovaných pomocí ITA se výrazně zlepšila a zvýšila v přímé úměře jak s rostoucí dobou síťování, tak s množstvím dvojných vazeb na koncích řetězců. Vzorek s 63 mol% ITA síťovaný 40 minut ve vodě zcela zdegradoval po 32 dnech. Protonovou NMR relaxometrií bylo zjištěno, že když vzorek ve vodě nabotnal (po cca 12 hodinách), množství nevázané vody se začalo snižovat a postupně difundovat do kavit na povrchu vzorku a pomalu se měnit na slabě a pevně vázanou vodu na polymerní řetězce. Nicméně, termální stabilita chemicky síťovaných vzorků vzrůstala pouze do 20 minut síťování. Pomocí ATR-FTIR bylo prokázáno, že se přibližně 57 % dvojných vazeb kyseliny itakonové (při vlnové délce 1640 cm-1) přeměnilo na nové jednoduché RR'C-CHR'' vazby při vlnové délce 795 cm-1. Delší čas síťování (nad 30 minut) vedl ke změnám v chemické struktuře pomocí beta-štěpení řetězců a částečné rekombinaci dvojných vazeb. Díky vzniku nových dvojných vazeb v jiných částech řetězce se snížila termální stabilita z 242 °C na 237° C a teplota skelného přechodu z -2,2 na -5.8 °C. Předložená práce popisuje, jak složení polymeru, modifikace funkčními skupinami a fyzikální podmínky ovlivňují fyzikální a chemické síťování připravených amfifilních kopolymerů. Kontrola hydrolytické a termální stability hydrogelů je zapotřebí zejména při uvolňování léčiv a regeneraci tkání.
548

Kostní implantáty na bázi železa / Bones implants based on Fe

Hávová, Mariana January 2016 (has links)
This thesis refers to Fe-based biodegradable materials and their potencial aplications in medicine, especially as temporary bone implants. This work generaly summaries aplications of biomaterial in medicine with more interest kept on biodegradable materials and their in-vivo corrosion. The experimental part refers to conduction of porous Fe-based materials with silica addition. The structure of prepared specimens is identified by EDX and XRD analysis. The imersion test and electrochemical studies were conducted to observe corrosion behaviour with respect to different concentration of silica. Potenciodynamic curves were obtained to determine corrosion potencial and corrosion current density of prepared samples.
549

Encapsulation of particles and cells using stimuli-responsive self-rolling polymer films

Zakharchenko, Svetlana 09 April 2014 (has links)
This thesis is focused on the design and development of an approach, allowing the fabrication of biocompatible/biodegradable self-rolled polymer tubes, which are sensitive to stimuli at physiological conditions, can be homogenously filled with cells and are able to self-assemble into a complex 3D construct with uniaxially aligned pores. These constructs are aimed to recreate the microstructure of tissues with structural anisotropy, such as of muscles and bones. The approach consists of two steps of self-assembly. As a first step, cells are adsorbed on the top of an unfolded bilayer; triggered rolling results in a parallel encapsulation of cells inside the tubes. As a second step, the formed self-rolled tubes with encapsulated cells can be assembled in a uniaxial tubular scaffold. Three polymer systems were designed and investigated in the present work in order to allow triggered folding of the bilayer. These systems allow either reversible or irreversible tube formation. The possibility to encapsulate microobjects inside self-rolled polymer tubes was demonstrated on the example of silica particles, yeast cells and mammalian cells. At conditions when bilayer film is unfolded, particles or cells were deposited from their aqueous dispersion on the top of bilayer. An appropriate change of conditions triggers folding of the bilayer and results in encapsulation of particles or cells inside the tubes. One way swelling of an active polymer allows irreversible encapsulation of cells in a way that tubes do not unroll and cells cannot escape. It was demonstrated that encapsulated cells can proliferate and divide inside the tubes for a long period of time. Since used polymers are optically transparent, encapsulated cells can be easily observed using optical and fluorescent microscopy. Reversible swelling of an active polymer provides the possibility to release encapsulated objects. It was demonstrated that in aqueous media microtubes possessing small amount of negatively charged groups on external walls self-assemble in the presence of oppositely charged microparticles that results in a formation of 3D constructs. In obtained aggregates tubes and therefore pores were well-aligned and the orientation degree was extremely high. Moreover, the approach allows the design of porous materials with complex architectures formed by tubes of different sorts. The assembly of cell-laden microtubes results in a formation of uniaxial tubular scaffold homogeneously filled with cells. The results presented in this work demonstrate that the proposed approach is of practical interest for biotechnological applications. Self-rolled tubes can be filled with cells during their folding providing the desired homogeneity of filling. Individual tubes of different diameters could be used to investigate cell behaviour in confinement in conditions of structural anisotropy as well as to mimic blood vessels. Due to their directionality tubes could be used to guide the growth of cells that is of interest for regeneration of neuronal tissue. Reversibly foldable films allow triggered capture and release of the cells that could be implemented for controlled cell delivery. In perspective, self-assembled 3D constructs with aligned pores could be used for bottom-up engineering of the scaffolds, mimicking such tissues as cortical bone and skeletal muscle, which are characterized by repeating longitudinal units. Such constructs can be also considered as a good alternative of traditional 2D flat cell culture.
550

Corrosion of additively manufactured magnesium alloy WE43 : An investigation in microstructure and corrosion properties of as built samples manufactured with Powder Bed Fusion-Laser Beam

Wahman, Clarence January 2021 (has links)
The work presented in this thesis was conducted at Uppsala University and at Swerim AB. The study aims to broaden the knowledge about the corrosion of additively manufactured bioresorbable alloy WE43 in humanlike conditions for future applications. Biodegradable metal implants are implants meant to stay in the body and support the wounded bone for a certain time period, and then degrade as new, healthy bone forms in its place. Magnesium alloys have properties that are desired for these kind of implants as it is biodegradable, non-toxic and matches the mechanical properties of bone. Furthermore, magnesium alloy WE43, containing yttrium, neodymium and zirconium, already exist on the market as a powder extruded screw that treats Hallux valgus, thus proves the alloys compatibility as a bioresorbable implant. However, in order to optimize implants for specific situations, additive manufacturing can be a powerful tool. By utilizing the advantages of additive manufacturing, patient specific, complex designs implant can be manufactured rapidly in order to be used in a patient. On the other hand, additive manufacturing is a complex method with many aspects affecting the outcome. Therefore it is important to study the influence that different parameters have on the material's properties, especially the corrosion properties. This thesis aims to study different power settings on the laser in the manufacturing process and what effect it has on the microstructure as well as the corrosion properties of as built WE43 samples. Samples of three different parameters settings were manufactured with a Powder Bed Fusion-Laser Beam 3Dprinter. These samples were analyzed regarding surface roughness and microstructure with Light Optical Microscope, Scanning Electron Microscope, Energy Dispersive Spectroscopy, Electron Backscatter Diffraction and Alicona InfiniteFocus. Furthermore, the corrosion properties of the samples were investigated by collecting and measuring hydrogen gas that is released during the corrosion process. In addition, the electrolyte were examined regarding the change in ion concentration and electrochemical tests were performed. It was found that the samples did not differ substantially in microstructure as all three parameter settings exhibited a matrix of magnesium and precipitates of alloying elements. However, the sample manufactured at the lowest energy density had pores incorporated in the bulk. Despite the porous bulk this sample performed best in the immersion tests and exhibited the lowest corrosion rate over 28 days. The reason for this behavior is not determined, however possible causes are discussed and further studies are recommended.

Page generated in 0.0336 seconds