• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1209
  • 44
  • 40
  • 39
  • 34
  • 27
  • 16
  • 12
  • 8
  • 8
  • 7
  • 5
  • 3
  • 1
  • 1
  • Tagged with
  • 1250
  • 648
  • 110
  • 102
  • 101
  • 101
  • 100
  • 92
  • 91
  • 86
  • 85
  • 76
  • 73
  • 73
  • 73
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Análise dinamométrica tridimensional da pedalada de ciclistas

Nabinger, Eduardo January 2006 (has links)
A busca por um melhor desempenho é uma motivação constante do ser humano. O desenvolvimento de estudos interdisciplinares em esportes permite a compreensão e o aperfeiçoamento deste desempenho. O ciclismo é um esporte altamente técnico e competitivo e a biomecânica do movimento humano apresenta técnicas que permitem descrever e avaliar a pedalada dos ciclistas. A técnica da pedalada é uma característica individual de cada ciclista e define a forma com que a força é aplicada sobre o pedal, depende da coordenação muscular, comprimento dos segmentos, alinhamento articular do ciclista, regulagens da bicicleta, cadência e carga utilizada. A dinamometria através da instrumentação do pedal tridimensional permite uma avaliação da efetividade da pedalada, uma relação entre a força aplicada e a força transmitida para o movimento. Com esta finalidade foi desenvolvida uma plataforma de força adaptada no pedal utilizando extensômetros (strain gauges) baseada em vigas em flexão que medem seis componentes de carga, três forças (normal, tangencial e lateral) e seus respectivos momentos. O posicionamento dos segmentos ao longo da pedalada é influenciada pelo alinhamento articular do ciclista. A utilização de acessórios permite modificar estes parâmetros com a finalidade de evitar lesões corrigindo o alinhamento do movimento. A influência destes acessórios na performance do ciclista e a redução da componente do momento My normal ao plano do pedal são os objetivos deste trabalho. Para analisar a influência destes acessórios foram realizadas medições em três ciclistas utilizando a célula de carga desenvolvida, utilizou-se um estudo de caso devido a diferentes aspectos antropométricos entre os ciclistas e a técnica da pedalada de cada ciclista que é uma característica individual. Em cada experimento o ciclista foi submetido a oito ensaios utilizando quatro acessórios diferentes (palmilha neutra, palmilha pronadora, palmilha supinadora e anel afastador) que modificavam a inclinação do pé. Cada ensaio foi comparado diretamente com um ensaio de referência onde verificou-se a efetividade na utilização dos acessórios e a alteração do momento My para cada ciclista. / Looking for a better performance is the continuous motivation for the human. The development of interdisciplinary studies in sports allows the compression and improvement of this performance. Cycling is very technical and competitive sport and biomechanics of the human movement show techniques that allow describing and estimate pedaling of cyclist. The technique of pedaling is a lonely characteristic of each cyclist and define the way that force is applied in the pedal, depends on muscular coordination, segments length, cyclist articular alignment, bicycle regulation, cadency and load utilized. Through dynamometry the pedal tridimentional instrumentation allow an evaluation of the efetitivity of the pedaling, a connection between applied force and transmitted force to the movement. With this purpose it was developed adapted force platform in the pedaling using strain gauges based in bean in flexion which the measurement of six load components, three forces (normal, tangential and lateral) and their respective moments. The segments orientation during the pedaling is influenced by cyclist articular alignment. Using accessories allow modifying these parameters with the finality of give up injuries correcting the alignment of the movement. The influence of these accessories in the performance of the cyclist and the reduction of normal My moment component are main objective of this thesis. In order to evaluated the accessories influence it was did measurement in three cyclists using a load cell developed. It was used a study for each case, because of the antropometrical aspects difference between the ciclysts and pedaling technique of each one. In all the experiments the ciclyst was submited to a eight tests using four differents acessories (neutral insoles, pronated insoles, supinated insoles, special ring) that modified the foot inclination. Each test was compared directly with the reference test, where it was verified the efetivity in the using of acessories and moment My alteration for each cyclist.
62

Avaliação da força aplicada à articulação do ombro em cadeirantes durante a manobra de transferência /

Silva, Regina Celia Aragão da. January 2012 (has links)
Orientador: Tamotsu Hirata / Banca: Jose Geraldo Trani Brandão / Banca: Cesar Ferreira Amorim / Resumo: O presente trabalho faz uso da instrumentação aplicada à biodinâmica do movimento humano para avaliar a força aplicada ao complexo articular do ombro de cadeirantes, durante a manobra de transferência, para conhecer o comportamento dinâmico dos músculos durante a transferência e, consequentemente, identificar a fase mais crítica da manobra. Para tanto, o estudo mensurou a atividade mioelétrica dos músculos Deltóide anterior, Tríceps Braquial, Peitoral Maior e Trapézio, envolvidos direta ou indiretamente com a manobra de transferência e a força de reação do solo. A amostra foi constituída de 4 voluntários, de ambos os sexos, com idade entre 40 e 42 anos, e com mais de 10 anos de experiência em cadeiras de rodas. Para tal, foi projetada e construída uma Plataforma de Força a fim de estimar-se o padrão de ativação muscular durante a realização da manobra. Analisamos os sinais elétricos proporcionais à força aplicada sobre a plataforma e, utilizando os dados cinemáticos e cinéticos, pudemos observar e concluir que durante a fase do pivô da transferência ocorreu a maior instabilidade na geração de força, pois através da EMG foram observados níveis diferentes de ativação muscular para as três fases da manobra, embora uma maior ativação dos músculos avaliados durante a fase de pivô. Entretanto, há uma necessidade de elaborar estratégias para minimizar os efeitos da sobrecarga e do estresse na articulação em questão e diminuir os riscos de lesões, através de exercícios de fortalecimento, alongamento e mudança no comportamento padrão do movimento da transferência / Abstract: This work makes use of the instrumentation applied to biodynamic of human movement from mechanical engineering to evaluate the force applied to the shoulder joint complex wheelchair during the transfer maneuver to identify the most critical phase of the maneuver. Therefore this study aimed to measure the myoelectric activity of the muscles Deltoid previous Brachial Triceps, Pectoralis Major and Trapeze, directly or indirectly involved with the operation of transfer and ground reaction force. The sample consisted of four volunteers of both sexes, aged between 40 and 42 years, and with over 10 years experience in wheelchairs. To this was designed and built a force platform, so we can estimate the muscle activation pattern during the maneuver and analyze the electrical signals proportional to the applied force on the platform, these analyzes were guided through the cinematic where we can obtain the full description movement. So through the kinematic and kinetic data, we can observe and conclude that during the pivot phase, of the transfer occurred to greater instability in the generation of force and through EMG observed the different levels of muscle activation for the three phases of the maneuver, although there is a higher activation muscles evaluated during the pivot phase. However, there is a need to develop strategies to minimize the effects of overload and stress in the joint in question and reduce the risk of injury through strengthening exercises, stretching and changing the default behavior of the movement of the transfer / Mestre
63

Estudo de um modelo dinâmico para avaliação física do corpo humano /

Russi, Pedro Carlos. January 2002 (has links)
Orientador: Tamotsu Hirata / Banca: Mauro Pedro Peres / Banca: marcos Valério Ribeiro / Resumo: O problema da modelagem da locomoção humana tem atraído a atenção de pesquisadores por muitos anos. A compreensão, análise e avaliação da marcha humana oferecem dados importantes para o uso de próteses dos membros inferiores. O objetivo deste trabalho é apresentar um modelo matemático da marcha humana, através de um modelo simplificado do corpo humano para que sirva de referência no trabalho de adaptação ao uso de próteses. O desenvolvimento da modelagem, parte da geometria dos membros inferiores num sistema de referência bidimensional e utiliza o princípio da diferença entre as energias cinética e potencial do sistema, ou seja, o método de Lagrange, introduzido na forma matricial. O modelo é representado na fase de oscilação, por dois segmentos interconectados com massas concentradas que oscila como um pêndulo duplo. Na fase de apoio é representado por três segmentos interconectados com massas concentradas que se movimenta como um pêndulo triplo invertido. Obtidas as equações que representam o modelo, os torques nas articulações do tornozelo, joelho e quadril são obtidos e a simulação numérica é realizada no programa MATLAB. Os resultados dos torques calculados apresentaram coerências com os da literatura, porém, na fase de apoio diferenças significativas foram registradas. / Abstract: The problem of human locomotion modeling has been attracting the researcher attention for many years. The understanding, analysis and evaluation of the human locomotion provide important data for the use of prostheses in the inferior parts of the body. The aim of this issue is to present a mathematical model of the human locomotion through a simplified model of the human body so that it serves as reference in the adaptation for prostheses usage. The modeling was developed using the geometry of the inferior parts of the body in a system of bidimensional references and applies the principle of difference between kinetic energies and potential of the system, in other words, the method of Lagrange, introduced in the form matrix. The model is represented in the oscillation phase, for two segments interconnected with concentrated masses which oscillates as a double pendulum. In the support phase it is represented in three segments interconnected with concentrated masses which move as an inverted triple pendulum. Since the equations representing the model are provided, the torque in the articulations of the ankle, knee and hip are obtained and the numeric simulation is accomplished in the program MATLAB. The results of the calculated torque showed coherence with the one of the literature, however, in the support phase the significant differences were registered.
64

Um dispositivo mecânico para avaliação da rigidez de tornozelo

Miranda, Vania Cristina dos Reis [UNESP] 07 February 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:33Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-02-07Bitstream added on 2014-06-13T20:58:27Z : No. of bitstreams: 1 miranda_vcr_me_guara.pdf: 1187305 bytes, checksum: 811e6b5436fed3f9f5db057bb4939a26 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A articulação do tornozelo é um segmento complexo no qual todas as suas estruturas necessitam agir harmoniosamente para se obter um movimento cadenciado durante as funções dos membros inferiores. Porém, com o processo de envelhecimento essas funções sofrem alterações como uma redução da amplitude dos movimentos, diminuição da força muscular, enrijecimento das articulações e um declínio da flexibilidade, que contribuem para a baixa eficiência mecânica da marcha aumentando o risco de quedas. Assim, na tentativa de conhecer cada vez mais esses parâmetros que envolvem a mecânica da marcha, instrumentos vêm sendo criados para facilitar e tornar mais precisa as avaliações biomecânicas e consequentemente elaborar programas de tratamento fisioterapêutico mais efetivos. Diante deste contexto o objetivo do estudo foi construir um dispositivo mecânico novo, de baixo custo, para avaliar quantitativamente a rigidez de tornozelo e fazer uma análise comparativa deste parâmetro entre adultos e idosos saudáveis. Esta avaliação foi efetuada por meio de um potenciômetro angular para a medição do deslocamento angular da referida articulação, e um sistema de viga-transdutor com extensômetros colados para a medição do momento aplicado pelo pé no dispositivo. Após a construção e calibração do dispositivo foi realizada a coleta de dados em uma amostra formada por dois grupos sendo um grupo controle com 12 indivíduos com idades entre vinte e cinquenta anos e um grupo idoso com 13 indivíduos com idades acima de sessenta anos. A partir dos resultados dos parâmetros analisados foi observado que idosos apresentam rigidez de tornozelo maior que adultos. Assim, conclui-se que o dispositivo em questão permite a avaliação da rigidez de tornozelo além de possibilitar o acompanhamento do tratamento de pacientes com problemas nesta articulação / The ankle joint is a complex segment in which all structures need to act in harmony to achieve a rhythmic movement during the functions of the lower limbs. But with the aging process, these functions are altered as a reduced range of motion, decreased muscle strength, joint stiffness and a decline in flexibility, contributing to the low mechanical efficiency of walking and increases the risk of falls. Thus, trying to know more and more these parameters involving the mechanics of motion, instruments are being created to facilitate and make more accurate assessments biomechanical and consequently develop programs of physiotherapy more effective. Given this context, the objective was to build a new mechanical device, low cost, to quantitatively assess the stiffness of the ankle and make a comparative analysis of this parameter between adults and seniors. This evaluation is done by means of a angular potentiometer to measure the displacement angle of that joint, and a system of beam transducer with strain gauges glued to the measurement of torque used by standing on the device. After construction and calibration of the device it was collected in a data sample consisting of two groups: one control group of 12 subjects aged between twenty and fifty years and a group of 13 elderly individuals aged over sixty years. From the results of the parameters analyzed was observed that the elderly have rigid ankle higher than adults. Thus, we conclude that the device in question allows the evaluation of the stiffness of the ankle and allow the monitoring of treatment of patients with problems in this joint
65

Análise biomecânica da marcha de mulheres com uso de sapatos com saltos em solo plano e inclinado

Silva, Glauce Gonzaga [UNESP] 21 December 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:33Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-12-21Bitstream added on 2014-06-13T20:58:25Z : No. of bitstreams: 1 silva_gg_me_guara.pdf: 1105448 bytes, checksum: a33711da0b06b111b309db48aa3e52cc (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / É grande o número de mulheres que faz uso de sapatos com saltos na atualidade durante várias horas por dia, sendo freqüentemente sujeitas a andarem por diversos tipos de superfícies, sejam elas planas ou inclinadas, submetendo o sistema músculoesquelético a esforços variados. Os objetivos do presente estudo foram: adaptar uma esteira para realização de análise biomecânica; analisar a marcha de mulheres com uso de sapatos com saltos em comparação com a condição descalça; analisar a influência da inclinação da superfície sobre o padrão de marcha dos indivíduos e relacionar o efeito da utilização do calçado com salto com o efeito da inclinação da superfície. Uma esteira elétrica foi adaptada através da colocação de plataformas de força independentes para o pé direito e esquerdo, com o uso de 8 anéis e 32 extensômetros em localização estratégica.Um tripé e uma câmera fotográfica digital foram utilizados para a análise cinemática do joelho direito no plano sagital.Dez voluntárias jovens e saudáveis participaram do estudo, andando sobre a esteira descalças e com uso de sapatos com saltos de 5,0 cm, no plano horizontal, inclinado a 1,83° e 3,61°. Cada condição foi analisada durante 10 segundos, totalizando 60 segundos de análise de cada voluntária. A análise estatística não-paramétrica (teste de Wilcoxon) (p<0,10) demonstrou que o uso de sapatos com saltos com 5 cm de altura associado à marcha em plano horizontal e inclinado de 1,83° e 3,61° não altera o ângulo mínimo de flexão do joelho no plano sagital, porém exerce influência sobre o ângulo máximo do mesmo no plano horizontal, diminuindo-o com o uso do calçado. Foi constatado também que o uso do referido calçado apresenta relação com a velocidade da marcha de forma inversamente proporcional à inclinação da superfície, com exceção da inclinação de 3,61° com... / Actually it's large the number of women that make use of high-heeled shoes for several hours a day, often being subdued to gait different types of surfaces, smooth and/or inclined, subjecting the musculoskeletal system to a variety of efforts. The present study’s intentions were: to adapt a treadmill for the biomechanical analysis; to analyze women’s gait using high heels in comparison with the barefoot condition; to analyze the influence of a slope surface over the march pattern of individuals and to relate the effect of high-heeled shoes utilization with the effect of a slope surface. An electronic treadmill was adapted with the installation of independent force platforms for the right and the left foot, using 8 rings and 32 strain gages in a strategic location. These were connected trough 2 channels to the Spider 8, responsible for acquisition and processing the signals which, connected to a computer, allowed the data analysis by the Catman® 3.1 software. It was necessary the utilization of a gear motor for the high-heels gait’s velocity adaptation. A tripod and a digital camera were used for kinematic analysis of the right knee in the sagittal plane. For synchronization of kinematic and kinetic data, we used a light signaling that allowed the simultaneous start of data acquisition. Ten healthy young women volunteers participated on the study, walking on the treadmill barefoot and wearing shoes with heels of 5.0 cm on the horizontal plane, inclined 1.83 ° and 3.61 °. Each condition was analyzed for 10 seconds, summarizing 60 seconds of analysis of each volunteer. The images were fragmented in Quintic Player ® software and relayed to the software ImageJ ®, through which were analyzed the angular variation. Statistical analysis Non-parametric (Wilcoxon test) by using significance p <0.10 showed that the use of shoes with with 5 cm heels associated with motion... (Complete abstract click electronic access below)
66

Elaboração de uma plataforma oscilatória para teste de equilíbrio dinâmico

Santos, Jomilto Luiz Praxedes dos [UNESP] 28 January 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:33Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-01-28Bitstream added on 2014-06-13T20:58:30Z : No. of bitstreams: 1 santos_jlp_me_guara.pdf: 1876074 bytes, checksum: 4123f2daecb149e7c9c340aaff7844f8 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo tem como objetivo elaborar e validar um protótipo de plataforma proprioceptiva que possibilite a mensuração e o monitoramento do comportamento cinemático dos estímulos perturbatórios gerados. Considerando que atualmente, a avaliação do equilíbrio postural em plataformas instável é realizada de forma qualitativa, sendo observado o quanto a plataforma oscilou, a estratégia proposta neste estudo permite quantificar o fenômeno oscilatório, permitindo futuras comparações entre exames, isto como uma forma de medida avaliativa dos participantes. Foi elaborada uma plataforma oscilatória que possibilitava a mensuração do seu deslocamento angular através de um potenciômetro. Para a validação do equipamento utilizou-se a técnica da videogrametria, sendo assim, durante a movimentação da plataforma coletou-se dados provenientes da plataforma e do potenciômetro. A plataforma instável construída e instrumentalizada neste trabalho foi capaz de mensurar e monitorar o comportamento cinemático dos estímulos perturbatórios gerados durante a sua movimentação, apresentando alto valor de correlação. Desta forma, pode-se substituir a técnica de videogrametria pela utilização do potenciômetro, tornando o exame mais prático. Este equipamento poderá ser útil para o estudo minucioso do equilíbrio e da estabilidade postural, no que tange a relação entre os estímulos perturbatórios gerados e a resposta motora do testado / This study aims to develop and validate an oscillating platform which enables the measurement and monitoring of the kinematics of the stimuli generated disturbing. Whereas today, the assessment of postural balance in an unstable platform is performed in a qualitative way, observing how the platform oscillated, the strategy proposed in this study to quantify the oscillatory phenomenon, allowing for future comparisons between tests, this measure as a form of evaluative participants. A oscillating platform was developed that allowed the measurement of its angular displacement with a potentiometer. For the validation of equipment used the technique of videogrammetry, so during the platform movement data was collected. The unstable platform built and manipulated in this study was able to measure and monitor the kinematics of the stimuli generated disturbing when they are moving at a high correlation value. Thus, one can replace the technique of videogrammetry the use of potentiometer, making the test more practical. This equipment may be useful for the detailed study of balance and postural stability, regarding the relationship between stimuli and motor response disturbing generated the test
67

Análise biomecânica instrumental da técnica de judô Morote Seoi Nage, através de uma metodologia de treinamento

Nagata, Eduardo Yoshinori [UNESP] 02 August 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:33Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-08-02Bitstream added on 2014-06-13T20:58:31Z : No. of bitstreams: 1 nagata_ey_me_guara.pdf: 791649 bytes, checksum: 1efe0eefda24d10c59961eebcddf116e (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O judô é um esporte muito praticado no mundo. Para o seu desenvolvimento necessita - se de uma quantidade maior de pesquisas na área de biomecânica. Devido ao esporte ser acíclico há muita dificuldade de conseguir equipamentos que façam análise da maneira mais próxima de uma situação real de luta. Este trabalho faz um estudo de uma metodologia de treinamento, utilizando plataforma de força, eletromiógrafo e técnicas de cinemetria, envolvendo a técnica de judô Morote Seoi Nage. O treinamento de entrada e projeção de golpes foi dividido em três situações diferentes. A primeira com o uke (atleta que recebe o golpe) estático, a segunda com o uke saltando e sendo projetado no momento ascendente da impulsão e a terceira com o uke saltando e sendo projetado no momento descendente da impulsão. Foram analisadas as atividades elétricas dos músculos Reto Femoral e Gastrocnêmio Médio do tori (atleta que executa o golpe) e a força de reação do solo do tori. Foram verificadas as diferenças do treinamento nas três situações. Na fase ascendente a força foi 36% menor comparada à fase descendente. Os resultados indicam que o método de treinamento proposto (fase ascendente) exigiu menor esforço para aplicação do golpe, utilizando um dos princípios definidos por Jigoro Kano, da máxima eficiência com menor esforço / Judo is a worldwide practiced sport. A larger amount of research in the biomechanics field is needed for its development. Given the fact that this is a non-cyclic sport, there is a lot of trouble in finding equipments that are able to perform evaluations closer enough to a real combat situation. This work studies a training method, using a force platform, electromyography, and image processing, involving the Morote Seoi Nage judo technique. The training of entry and projection of strikes was divided in three different situations. The first with a static uke (the athlete that is being stroken), the second with a jumping uke being projected at the upwards impulsion instant and the third with a jumping uke being projected at the downwards impulsion instant. The electrical activities of the tori’s rectus femoris and the gastrocnemius muscles (tori is the athlete that performs the strike) were analyzed as well as its ground reaction force. The training differences between the three situations were analyzed. The results show that the proposed training method (upward phase) required less effort when the strike is performed, requiring 36% less effort compared to the downwards phase, using one of the rudiments defined by Jigoro Kano, of the maximal efficiency with the minimum effort
68

Avaliação de instrumentos para inserção de ligaduras elásticas em aparelho ortodôntico

Varella, Jairo Ribeiro [UNESP] 26 February 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:34Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-02-26Bitstream added on 2014-06-13T19:16:36Z : No. of bitstreams: 1 varella_jr_me_guara.pdf: 411771 bytes, checksum: 6018f061abb7c0ab68b42665d02bafa9 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo do trabalho foi determinar parâmetros para avaliar a pinça insersora de ligadura elástica, comparando-a com o aplicador de ligadura elástica. Foi idealizado e construído um dispositivo para medir a força de deslocamento da ligadura elástica, composto por transdutores de força e deslocamento, condicionador de sinais, placa de aquisição de dados e um computador. Para determinar a força de deslocamento foram utilizadas 58 ligaduras elásticas, sendo 29 ligaduras colocadas com o aplicador e 29 inseridas com a pinça. Os resultados mostraram que as ligaduras colocadas com a pinça necessitaram de uma força de deslocamento maior. As medidas da amostra de 45 ligaduras no projetor de perfil mostraram que a pinça esticou menos as ligaduras elásticas durante a manobra de inserção no braquete. O diagrama tensão x deformação específica ilustra que a inserção com o aplicador gera maiores tensões nas ligaduras elásticas do que a pinça insersora, estas tensões podem ser responsáveis pela quebra das ligações cruzadas o que resulta numa degradação das propriedades físicas do elastômero. / The aim of this work is to determine parameters to evaluate the applying clamp of elastic tie, comparing it with the applicator of elastic tie. It was idealized and constructed a device to measure the displacement force of the elastic tie, being constituded of force and displacement transducers, signals conditioner, data acquisition plate and a computer. To determine the displacement forces, 58 elastic ties had been used, 29 of them being positioned with the applicator and the 29 other on being positioned with the help of the clamp. The results had shown that the ties positioned with the clamp required a bigger displacement force. The measurements of a sample of 45 ties made in a profile projector had shown that the ties positioned with the clamp has strained less during the act of insertion. The stress x strain diagram shows that the insertion made with the applicator creates bigger stress in the elastic ties than the stress when the applying clamp is used. These stress can be responsible for the crossed linking, and in addition results in a degradation in the physical properties of the elastomer.
69

Dispositivo para avaliar a força muscular dos membros superiores

Cortez, Paulo José Oliveira [UNESP] 21 August 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:34Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-08-21Bitstream added on 2014-06-13T18:57:55Z : No. of bitstreams: 1 cortez_pjo_me_guara.pdf: 2510243 bytes, checksum: 26b672349be7c1399c87d0ca359b2271 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Os objetivos do presente trabalho foram o desenvolvimento de um dispositivo capaz de mensurar a força muscular gerada pelos músculos do membro superior e, a verificação do funcionamento e adaptabilidade desse dispositivo, através de um estudo comparativo da força muscular em sujeitos saudáveis. Foi idealizada uma Estação de Medição de Força para avaliar a força muscular dos membros superiores a partir de contrações isométricas na direção vertical (flexão) e horizontal (rotação) contendo transdutores, condicionador de sinais e placa de aquisição de dados e, por fim, um computador. Após a construção e calibração do dispositivo, foi realizado um estudo comparativo da força muscular. Participaram do estudo 22 sujeitos do sexo masculino, com idade de 18 e 19 anos, militares, massa corpórea entre 57,7 e 93 kg (71,8 ± 9,45 kg) e com estatura entre 1,67 e 1,90 m (1,75 ± 0,06 m), saudáveis e sem história clínica de patologia ortopédica ou qualquer tipo de lesão no sistema músculoesquelético. Foram aplicados 3 testes de força: Flexão (sentido vertical), Rotação Interna e Rotação Externa (sentido horizontal). Para cada tipo de esforço foram solicitadas 3 (três) contrações voluntárias máximas por 10 segundos, com intervalo de 30 segundos entre cada contração. Através da análise comparativa dos dados, foi observada semelhança estatística entre as forças geradas pelo membro superior direito e esquerdo. Conclui-se que o dispositivo construído e testado apresenta inúmeras possibilidades para a análise biomecânica. / The aim of this study were the development of a device capable of measuring the muscle strength generated by the muscles of the upper limb and verification of efficiency and adaptability of this device through a comparative study of muscle strength in healthy subjects. It was an idealized Measurement of Force Station, to measure the muscular strength of senior members from isometric contractions in vertical direction (flexion) and horizontal (rotation) containing transducers, signal conditioning and data acquisition card and, finally, a computer. After the construction and calibration of the device it was made a comparative study of muscle strength. Twenty two make people participated in this study , were male, aged 18 and 19 years, military, body mass between 57.7 and 93 kg (71.8 ± 9.45 kg) and height between 1.67 and 1.90 m (1.75 ± 0.06 m), and healthy with no history of clinical orthopedic pathology or any kind of damage to the musculo-skeletal system. It was applied 3 tests of strength: Flexion (vertical direction), internal rotation and lateral rotation (horizontal direction). For each type of effort were required three (3) maximum voluntary contractions for 10 seconds, with an interval of 30 seconds between each contraction. Through analysis of comparative data, was observed statistical similarity between the forces generated by the upper right and left limbs. It was concluded that the device built and tested presents many possibilities for biomechanical analysis.
70

Avaliação da força aplicada à articulação do ombro em cadeirantes durante a manobra de transferência

Silva, Regina Celia Aragão da [UNESP] 27 August 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:47Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-08-27Bitstream added on 2014-06-13T18:52:42Z : No. of bitstreams: 1 silva_rca_me_guara.pdf: 699085 bytes, checksum: a6261555bb92507eb0dbaeceaff21bd7 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O presente trabalho faz uso da instrumentação aplicada à biodinâmica do movimento humano para avaliar a força aplicada ao complexo articular do ombro de cadeirantes, durante a manobra de transferência, para conhecer o comportamento dinâmico dos músculos durante a transferência e, consequentemente, identificar a fase mais crítica da manobra. Para tanto, o estudo mensurou a atividade mioelétrica dos músculos Deltóide anterior, Tríceps Braquial, Peitoral Maior e Trapézio, envolvidos direta ou indiretamente com a manobra de transferência e a força de reação do solo. A amostra foi constituída de 4 voluntários, de ambos os sexos, com idade entre 40 e 42 anos, e com mais de 10 anos de experiência em cadeiras de rodas. Para tal, foi projetada e construída uma Plataforma de Força a fim de estimar-se o padrão de ativação muscular durante a realização da manobra. Analisamos os sinais elétricos proporcionais à força aplicada sobre a plataforma e, utilizando os dados cinemáticos e cinéticos, pudemos observar e concluir que durante a fase do pivô da transferência ocorreu a maior instabilidade na geração de força, pois através da EMG foram observados níveis diferentes de ativação muscular para as três fases da manobra, embora uma maior ativação dos músculos avaliados durante a fase de pivô. Entretanto, há uma necessidade de elaborar estratégias para minimizar os efeitos da sobrecarga e do estresse na articulação em questão e diminuir os riscos de lesões, através de exercícios de fortalecimento, alongamento e mudança no comportamento padrão do movimento da transferência / This work makes use of the instrumentation applied to biodynamic of human movement from mechanical engineering to evaluate the force applied to the shoulder joint complex wheelchair during the transfer maneuver to identify the most critical phase of the maneuver. Therefore this study aimed to measure the myoelectric activity of the muscles Deltoid previous Brachial Triceps, Pectoralis Major and Trapeze, directly or indirectly involved with the operation of transfer and ground reaction force. The sample consisted of four volunteers of both sexes, aged between 40 and 42 years, and with over 10 years experience in wheelchairs. To this was designed and built a force platform, so we can estimate the muscle activation pattern during the maneuver and analyze the electrical signals proportional to the applied force on the platform, these analyzes were guided through the cinematic where we can obtain the full description movement. So through the kinematic and kinetic data, we can observe and conclude that during the pivot phase, of the transfer occurred to greater instability in the generation of force and through EMG observed the different levels of muscle activation for the three phases of the maneuver, although there is a higher activation muscles evaluated during the pivot phase. However, there is a need to develop strategies to minimize the effects of overload and stress in the joint in question and reduce the risk of injury through strengthening exercises, stretching and changing the default behavior of the movement of the transfer

Page generated in 0.3554 seconds