Spelling suggestions: "subject:"boilers."" "subject:"oilers.""
71 |
Avaliação experimental de eficiência térmica de um recuperador de calor e caldeira em um sistema de cogeraçãoNeves, Ricardo Cecilio Moreno das [UNESP] 11 July 2014 (has links) (PDF)
Made available in DSpace on 2015-03-03T11:52:40Z (GMT). No. of bitstreams: 0
Previous issue date: 2014-07-11Bitstream added on 2015-03-03T12:06:10Z : No. of bitstreams: 1
000800334.pdf: 1312816 bytes, checksum: 8b4c8150b35e885b4e6f39567fe2c6b6 (MD5) / A escassez dos bens naturais e os constantes aperfeiçoamentos na área de energias renováveis exigem cada vez mais a busca por melhores condições e tecnologias para melhor aproveitamento energético em processos de combustão. O conjunto denominado pré-aquecedor de ar pode ser considerado o mais importante para a melhoria do processo de combustão de caldeiras convencionais. Este trocador está diretamente ligado à recuperação da energia disponível nos gases de combustão por contato indireto. A incrustação de fuligem (mistura de cinza e sílica) inerente ao processo de combustão é um dos fatores que mais impactam no rendimento térmico do equipamento. O presente trabalho analisa de forma transiente o efeito da incrustação sobre a parede interna dos tubos deste trocador de calor. Para isso, dois métodos para análise de desempenho foram utilizados, sendo o método definido neste trabalho como convencional, e o método proposto pela ASME (Performance Test Code 4.3 | PTC 4.3). Os resultados mostraram que embora o método convencional tenha apresentado valor médio de desempenho de 35% e o método ASME valor médio de 40%, ambos possuem o mesmo perfil, validando assim o método convencional. Além das análises de desempenho, outros resultados foram obtidos a partir dos dados determinados experimentalmente. Para realização deste trabalho, uma caldeira de alta pressão foi utilizada, sendo os dados de vazão dos fluxos de ar e gases para o método convencional, obtidos com a utilização de tubos de Pitot e tudo de Venturi desenvolvido especialmente para esta aplicacão / The scarcity of natural resources and the constant improvements in the area of renewable energies are forcing increasingly to search for better conditions and better technologies for energy recovery from combustion processes. The set called air pre-heater can be considered the most important for improving the combustion process of conventional boilers. This heat exchanger is directly linked to the recovery of the available energy in the flue gas by indirect contact. The fouling of soot (mixture of ash and silica) inherent in the combustion process is one of the factors that most impact the thermal performance of the device. This study examines by transient form, the fouling effect on the inner wall of the heat exchanger tubes of this. For this, two methods for performance analysis were used, the method defined in this study as Conventional, and the method proposed by the ASME (Performance Test Code 4.3 | 4.3 PTC). The results showed that although the Conventional method has shown average performance of 35% and the method ASME average of 40%, both have the same profile, thus validating the Conventional method. Besides the analysis of performance, other results were obtained from data determined experimentally. For this study, a high-pressure boiler was used, and the data of air flow and gas flow to the conventional method obtained with the use of Pilot tubes and Venturi specially developed for this application
|
72 |
Medição da camada de óxidos em tubos de superaquecedores de caldeiras aquatubulares por ultrassomBraga, Rubem Manoel de January 2009 (has links)
O principal objetivo desse trabalho foi desenvolver um procedimento de medição para a espessura da camada de óxidos do interior de tubos de caldeiras aquatubulares utilizando o ensaio de ultrassom. A fim de confirmar os resultados das medições por ultrassom foram também feitas medições dessas camadas por metalografia e, com base nos seus valores, foram calculadas as temperaturas médias de operação dos tubos e comparadas com a temperatura de projeto prevista. A medição da espessura dessa camada de óxidos faz parte de uma técnica para buscar informações das condições operacionais do tubo, uma vez que existe uma relação matemática entre a espessura dessa camada, o tempo e a temperatura de operação do tubo. Esse trabalho teve uma grande ligação com a prática, pois foi desenvolvido para ser aplicado como uma técnica para auxiliar na avaliação das causas de ruptura dos tubos do superaquecedor de uma caldeira em operação. Os estudos descritos nesse trabalho, feitos com amostras retiradas de uma caldeira e com base em informações de tempo de operação fornecidos pela empresa proprietária da caldeira, permitiram confirmar que é possível medir camadas de magnetita a partir de valores entre 0,10 e 0,15mm (100 e 150µm) por ultrassom, no entanto para as condições práticas de campo é mais seguro considerar o valor limite mínimo de 0,20mm (200µm). Foi constatado também que a medição de espessura da camada de óxido em um lote de tubos por meio do ensaio de ultrassom necessita ser confirmada em ao menos uma amostra de tubo por meio do exame metalográfico. Isso se deve ao fato que o exame metalográfico confirma ou refuta os resultados do ultrassom e permite obter várias informações adicionais importantes sobre o tipo de camada e microestrutura do material. / The main aim of this work was to develop a thickness measurement procedure for the internal oxide layer thickness of aquatubular boilers tubes by means of ultrasound test. To confirm the measurement results by ultra-sound were also made layer measurements by means of metallography and, based on these values, the medium operation temperatures were calculated and compared with the temperatures of the project. The measurement of the oxide layer is part of a technique to obtain information about the operational conditions of the tube, because there is a mathematical relationship between the thickness of the layer, the time and the temperature of tube operation. This work was performed on samples extracted from an industrial boiler and could be used as a tool to aid in the analysis of superheater tubes that fail in service. The operational time data of the boiler was obtained from the industry and confirmed that it is possible to measure oxide layers from values between 0,10mm and 0,15mm (100µm and 150µm) by means of ultrasound testing, but for the practical field conditions it is more secure to consider the minimum limit value 0,20mm (200µm). It was also verified that the oxide layer thickness measurement of a lot of tubes by means of ultra-sound need to be confirmed in at least one tube sample by means of metallographic exam. This is due the fact that metallographic exam confirms or refutes the ultrasound test results and permits several additional important information about the layer type and material microstructure.
|
73 |
Medição da camada de óxidos em tubos de superaquecedores de caldeiras aquatubulares por ultrassomBraga, Rubem Manoel de January 2009 (has links)
O principal objetivo desse trabalho foi desenvolver um procedimento de medição para a espessura da camada de óxidos do interior de tubos de caldeiras aquatubulares utilizando o ensaio de ultrassom. A fim de confirmar os resultados das medições por ultrassom foram também feitas medições dessas camadas por metalografia e, com base nos seus valores, foram calculadas as temperaturas médias de operação dos tubos e comparadas com a temperatura de projeto prevista. A medição da espessura dessa camada de óxidos faz parte de uma técnica para buscar informações das condições operacionais do tubo, uma vez que existe uma relação matemática entre a espessura dessa camada, o tempo e a temperatura de operação do tubo. Esse trabalho teve uma grande ligação com a prática, pois foi desenvolvido para ser aplicado como uma técnica para auxiliar na avaliação das causas de ruptura dos tubos do superaquecedor de uma caldeira em operação. Os estudos descritos nesse trabalho, feitos com amostras retiradas de uma caldeira e com base em informações de tempo de operação fornecidos pela empresa proprietária da caldeira, permitiram confirmar que é possível medir camadas de magnetita a partir de valores entre 0,10 e 0,15mm (100 e 150µm) por ultrassom, no entanto para as condições práticas de campo é mais seguro considerar o valor limite mínimo de 0,20mm (200µm). Foi constatado também que a medição de espessura da camada de óxido em um lote de tubos por meio do ensaio de ultrassom necessita ser confirmada em ao menos uma amostra de tubo por meio do exame metalográfico. Isso se deve ao fato que o exame metalográfico confirma ou refuta os resultados do ultrassom e permite obter várias informações adicionais importantes sobre o tipo de camada e microestrutura do material. / The main aim of this work was to develop a thickness measurement procedure for the internal oxide layer thickness of aquatubular boilers tubes by means of ultrasound test. To confirm the measurement results by ultra-sound were also made layer measurements by means of metallography and, based on these values, the medium operation temperatures were calculated and compared with the temperatures of the project. The measurement of the oxide layer is part of a technique to obtain information about the operational conditions of the tube, because there is a mathematical relationship between the thickness of the layer, the time and the temperature of tube operation. This work was performed on samples extracted from an industrial boiler and could be used as a tool to aid in the analysis of superheater tubes that fail in service. The operational time data of the boiler was obtained from the industry and confirmed that it is possible to measure oxide layers from values between 0,10mm and 0,15mm (100µm and 150µm) by means of ultrasound testing, but for the practical field conditions it is more secure to consider the minimum limit value 0,20mm (200µm). It was also verified that the oxide layer thickness measurement of a lot of tubes by means of ultra-sound need to be confirmed in at least one tube sample by means of metallographic exam. This is due the fact that metallographic exam confirms or refutes the ultrasound test results and permits several additional important information about the layer type and material microstructure.
|
74 |
Avaliação experimental de eficiência térmica de um recuperador de calor e caldeira em um sistema de cogeração /Neves, Ricardo Cecilio Moreno das. January 2014 (has links)
Orientador: Alcides Padilha / Banca: Kamal Abdel Radi Ismail / Banca: Vicente Luiz Scalon / Resumo: A escassez dos bens naturais e os constantes aperfeiçoamentos na área de energias renováveis exigem cada vez mais a busca por melhores condições e tecnologias para melhor aproveitamento energético em processos de combustão. O conjunto denominado pré-aquecedor de ar pode ser considerado o mais importante para a melhoria do processo de combustão de caldeiras convencionais. Este trocador está diretamente ligado à recuperação da energia disponível nos gases de combustão por contato indireto. A incrustação de fuligem (mistura de cinza e sílica) inerente ao processo de combustão é um dos fatores que mais impactam no rendimento térmico do equipamento. O presente trabalho analisa de forma transiente o efeito da incrustação sobre a parede interna dos tubos deste trocador de calor. Para isso, dois métodos para análise de desempenho foram utilizados, sendo o método definido neste trabalho como convencional, e o método proposto pela ASME (Performance Test Code 4.3 | PTC 4.3). Os resultados mostraram que embora o método convencional tenha apresentado valor médio de desempenho de 35% e o método ASME valor médio de 40%, ambos possuem o mesmo perfil, validando assim o método convencional. Além das análises de desempenho, outros resultados foram obtidos a partir dos dados determinados experimentalmente. Para realização deste trabalho, uma caldeira de alta pressão foi utilizada, sendo os dados de vazão dos fluxos de ar e gases para o método convencional, obtidos com a utilização de tubos de Pitot e tudo de Venturi desenvolvido especialmente para esta aplicacão / Abstract: The scarcity of natural resources and the constant improvements in the area of renewable energies are forcing increasingly to search for better conditions and better technologies for energy recovery from combustion processes. The set called air pre-heater can be considered the most important for improving the combustion process of conventional boilers. This heat exchanger is directly linked to the recovery of the available energy in the flue gas by indirect contact. The fouling of soot (mixture of ash and silica) inherent in the combustion process is one of the factors that most impact the thermal performance of the device. This study examines by transient form, the fouling effect on the inner wall of the heat exchanger tubes of this. For this, two methods for performance analysis were used, the method defined in this study as Conventional, and the method proposed by the ASME (Performance Test Code 4.3 | 4.3 PTC). The results showed that although the Conventional method has shown average performance of 35% and the method ASME average of 40%, both have the same profile, thus validating the Conventional method. Besides the analysis of performance, other results were obtained from data determined experimentally. For this study, a high-pressure boiler was used, and the data of air flow and gas flow to the conventional method obtained with the use of Pilot tubes and Venturi specially developed for this application / Mestre
|
75 |
Medição da camada de óxidos em tubos de superaquecedores de caldeiras aquatubulares por ultrassomBraga, Rubem Manoel de January 2009 (has links)
O principal objetivo desse trabalho foi desenvolver um procedimento de medição para a espessura da camada de óxidos do interior de tubos de caldeiras aquatubulares utilizando o ensaio de ultrassom. A fim de confirmar os resultados das medições por ultrassom foram também feitas medições dessas camadas por metalografia e, com base nos seus valores, foram calculadas as temperaturas médias de operação dos tubos e comparadas com a temperatura de projeto prevista. A medição da espessura dessa camada de óxidos faz parte de uma técnica para buscar informações das condições operacionais do tubo, uma vez que existe uma relação matemática entre a espessura dessa camada, o tempo e a temperatura de operação do tubo. Esse trabalho teve uma grande ligação com a prática, pois foi desenvolvido para ser aplicado como uma técnica para auxiliar na avaliação das causas de ruptura dos tubos do superaquecedor de uma caldeira em operação. Os estudos descritos nesse trabalho, feitos com amostras retiradas de uma caldeira e com base em informações de tempo de operação fornecidos pela empresa proprietária da caldeira, permitiram confirmar que é possível medir camadas de magnetita a partir de valores entre 0,10 e 0,15mm (100 e 150µm) por ultrassom, no entanto para as condições práticas de campo é mais seguro considerar o valor limite mínimo de 0,20mm (200µm). Foi constatado também que a medição de espessura da camada de óxido em um lote de tubos por meio do ensaio de ultrassom necessita ser confirmada em ao menos uma amostra de tubo por meio do exame metalográfico. Isso se deve ao fato que o exame metalográfico confirma ou refuta os resultados do ultrassom e permite obter várias informações adicionais importantes sobre o tipo de camada e microestrutura do material. / The main aim of this work was to develop a thickness measurement procedure for the internal oxide layer thickness of aquatubular boilers tubes by means of ultrasound test. To confirm the measurement results by ultra-sound were also made layer measurements by means of metallography and, based on these values, the medium operation temperatures were calculated and compared with the temperatures of the project. The measurement of the oxide layer is part of a technique to obtain information about the operational conditions of the tube, because there is a mathematical relationship between the thickness of the layer, the time and the temperature of tube operation. This work was performed on samples extracted from an industrial boiler and could be used as a tool to aid in the analysis of superheater tubes that fail in service. The operational time data of the boiler was obtained from the industry and confirmed that it is possible to measure oxide layers from values between 0,10mm and 0,15mm (100µm and 150µm) by means of ultrasound testing, but for the practical field conditions it is more secure to consider the minimum limit value 0,20mm (200µm). It was also verified that the oxide layer thickness measurement of a lot of tubes by means of ultra-sound need to be confirmed in at least one tube sample by means of metallographic exam. This is due the fact that metallographic exam confirms or refutes the ultrasound test results and permits several additional important information about the layer type and material microstructure.
|
76 |
Modelagem simplificada e simulação da combustão de uma partícula de biomassa suspensa em escoamento unidimensional / Simplified modeling and simulation of combustion of a biomass particle suspended in one-dimensional flowNavarrete Cereijo, Germán, 1988- 12 February 2014 (has links)
Orientador: Waldir Antônio Bizzo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica / Made available in DSpace on 2018-08-26T13:11:12Z (GMT). No. of bitstreams: 1
NavarreteCereijo_German_M.pdf: 5308158 bytes, checksum: e2000224af9eab9b23e1890faab22618 (MD5)
Previous issue date: 2014 / Resumo: Este trabalho objetivou o desenvolvimento de um modelo simples para a simulação numérica da combustão de uma partícula pequena de bagaço numa fornalha industrial. Com este fim foi feito um estudo das principais etapas na combustão de uma partícula de biomassa: secagem, devolatili- zação, gaseificação e combustão do carvão. Destaca-se os modelos cinéticos para cada etapa e os mecanismos de transferência de calor por radiação em gases e de massa por convecção. Também foi modelada a trajetória vertical da partícula baseando-se nas forças de empuxo, peso e a força de arrasto com o objetivo de desenvolver uma ferramenta para determinar quais partículas são quei- madas em suspensão, quais são queimadas na grelha e quais são arrastradas pelo escoamento de gases. Para a simulação foi desenvolvido um programa em Fortran 90 onde a resolução numérica das equações diferenciais governantes é feita utilizando o método de Runge-Kutta de quarta ordem. As equações governantes para as taxas de consumo da biomassa são determinadas a partir da cinética das reações e do transporte de massa por convecção. A devolatilização é modelada como uma pi- rólise cujo mecanismo de reação é modelado por uma equação cinética de primeira ordem baseada nos parâmetros de Arrhenius. A taxa de consumo de carvão é determinada por duas equações ciné- ticas de primeira ordem baseadas nos parâmetros de Arrhenius que representam a oxidação direta do carbono e a gaseificação do carbono utilizando como reagente o dióxido de carbono. As equa- ções governantes para a temperatura da partícula são determinadas a partir dos balanços de energia para cada etapa. A validação do modelo foi feita em base a outros modelos apresentados na literatura para par- tículas menores a 1 mm obtendo-se resultados consistentes. Nos resultados apresentam-se gráficos de massa, raio, composição e temperatura da partícula, fração molar de oxigênio na superfície da partícula, taxa de consumo da biomassa, e raio do frente de chama em função do tempo tanto para partículas esféricas como cilíndricas. Também apresentam-se gráficas da trajetória e velocidade da partícula variando a forma e tamanho desta e a velocidade do escoamento dos gases dentro da fornalha / Abstract: The aim of this work is to develop a simple model for the numerical simulation of the com- bustion of a small particle of bagasse in an industrial furnace. To this end a study of the main stages of the biomass particle combustion was carried out. Thats stages are: drying, devolatiliza- tion, char gasification and char combustion. Kinetics models for each stage and the mechanisms of heat transfer by radiation in gases and convective mass models are presented in details. Also, the vertical trajectory of the particle was modeled based on buoyant force, weight and drag force in order to develop a tool for determine which particles are burned in suspension, which are burned on the grate and which are dragged by the gas flow. It was developed a program in Fortran 90 where the numerical solution of the governing diffe- rential equations is done using a fourth order Runge-Kutta. The governing equations for the bio- mass consumption rates are determined by kinetics equations and convection mass transport. The devolatilization is modeled as a pyrolysis which reaction mechanism is modeled by a first order kinetic equation based on the Arrhenius parameters. The rate of coal consumption is determined by two first-order kinetics equations based on the Arrhenius parameters that represent the direct char oxidation and char gasification using as reagent carbon dioxide. The governing equations for the particle temperature are determined from the energy balance for each stage. Model validation is carried out by comparing the predictions with other models taken from the literature for particles smaller than 1 mm giving consistent results. The results are presented plotting the following variables as a function of time: particle mass, raio, composition and tempe- rature, oxygen concentration on the particle surface, consumption rate of biomass and flame front raio for both spherical and cylindrical particle. Also, graphics of the particle speed and trajectory are presented, varying particle¿s shape and size and gas flow velocity of gases inside the furnace / Mestrado / Termica e Fluidos / Mestre em Engenharia Mecânica
|
77 |
Electronic Model of Turbine Generator Including Reheaters, Governor and Shaft Torsional SystemLegault, Pierre R. 04 1900 (has links)
No description available.
|
78 |
An investigation of flow-induced vibrations of a steam-generator tubeYanna, Marc-Gabriel 21 July 2009 (has links)
A typical failure in a heat exchanger is the breakdown of a tube due to impact-sliding wear. We investigate the dynamic behavior of a tube subjected to cross flow and study the stability of periodic solutions, bifurcations, and the route to chaos. The fluid-stiffness-controlled mechanism is chosen to represent the fluid forces and the impact forces are modeled by a piece-wise-Iinear spring. A two-point boundary-value algorithm is used to calculate periodic solutions and Floquet theory is used to study their stability. Poincare sections and bifurcation diagrams are used to study non-periodic solutions. Furthermore. for this autonomous system, the method of harmonic balance appears to be less suited than the two-point boundary-value algorithm for calculating periodic motions. For the case of a single-mode approximation. the results show that the tube undergoes relaxation oscillations and hence no bifurcations occur for fluid velocities ranging from 1.1 Ve to 3.0 Ve, where Ve is the critical fluid velocity. For the cases of two- and three-mode approximations. the results show that periodic solutions undergo bifurcations leading to chaos. Consequently. we conclude that chaos is the result of modal interactions. Observing the details of impacts. we also conclude that chaos appears when a second impact occurs on the same stopper. We also found intermittent chaos alternating with transient periodic motions. Lastly, we estimate the mean impact forces and mean impact-sliding wear work rates and compare them with previous results. / Master of Science
|
79 |
Efficiency test of the dust collector on No.6 boiler in the V.P.I. power plantTruitt, James Linford, Riel, Richard H. 07 November 2012 (has links)
From the tests run it was observed that load variations have a pronounced effect both on size analysis and concentration of the flyash. / Master of Science
|
80 |
The determination of phosphates in boiler salinesJohnston, James Chapman January 1939 (has links)
M.S.
|
Page generated in 0.0441 seconds