• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 301
  • 56
  • 10
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 425
  • 425
  • 230
  • 136
  • 95
  • 94
  • 92
  • 84
  • 78
  • 75
  • 71
  • 71
  • 71
  • 62
  • 51
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
301

Efeito da radioterapia na adesão e interface ao substrato de dentes permanentes / Effect of radiotherapy on bonding and bonding interface to substrate of permanent teeth

Juliana Arid 27 November 2015 (has links)
O câncer de cabeça e pescoço é, dentre todos os tipos de cânceres, o sétimo mais comum, dentre suas principais formas de tratamento está a radioterapia (RT), que é amplamente utilizada e eficiente, mas os efeitos colaterais aos tecidos adjacentes são inevitáveis. A realização do tratamento odontológico previamente a radioterapia é de suma importância e visa eliminar/reduzir os focos infecciosos presentes na cavidade bucal, sendo essencial a eliminação das lesões de cárie, e após a radioterapia é fundamental tratar as \"cáries de radiação\", que é um dos efeitos colaterais do tratamento radioterápico de cabeça e pescoço. Os sistemas resinosos são os materiais mais indicados para restauração dos dentes de pacientes submetidos à radioterapia, por isso o objetivo do presente estudo foi avaliar in vitro o efeito da radiação, no momento em que é realizada a restauração ao esmalte e a dentina, por meio de teste de cisalhamento, analisar longitudinalmente as alterações morfológicas na superfície do substrato dental durante a radiação por meio de microscopia confocal a laser e analisar qualitativamente a interface de união compósito/substrato dental por meio de microscopia eletrônica de varredura (MEV). Foram utilizados 60 terceiros molares permanentes, que foram seccionados em um total de 120 fragmentos de esmalte e 120 de dentina, e após o preparo da superfície foram divididos aleatoriamente em grupos 4 grupos (n=30): G1 (controle) - substrato sem irradiação + procedimento restaurador; G2 - procedimento restaurador realizado antes da RT; G3 - procedimento restaurador realizado após a RT; e G4 - procedimento restaurador realizado 6 meses após a RT. Cada um dos grupos foi dividido em 2 subgrupos, sendo empregado no subgrupo \"A\" (SGA) o adesivo AdperTM Single Bond 2 (SB); e no subgrupo \"B\" (SGB) o adesivo Clearfil SE Bond (CL), para o procedimento restaurador. Os espécimes foram irradiados com fração de dose de 2Gy, 5 dias consecutivos, até atingirem a dose total de 60Gy, com um total de 30 frações, durante 6 semanas. O procedimento restaurador foi realizado com resina Z350, e para padronização da restauração foi utilizada uma matriz, de forma que os espécimes apresentam 4mm de altura e 2mm de diâmetro. Os corpos de prova foram submetidos ao teste de resistência ao cisalhamento e depois analisou-se o modo de fratura. Foram selecionados 5 espécimes de cada substrato, para a realização da análise morfológica da superfície dental por meio da microscopia confocal, sendo estes avaliados a cada 10Gy. Para a análise da interface adesiva foram selecionados 3 espécimes de cada grupo e estes foram preparados para realização da MEV. O sistema adesivo CL apresentou desempenho superior, em ambos substratos, quando comparado o SB; quanto ao tempo da restauração, tanto em esmalte quanto em dentina, o grupo 2 apresentou os menores valores; o padrão de fratura predominante para todos os grupos foi a Adesiva; houveram alterações morfológicas notáveis em esmalte e dentina após a dose acumulativa de 30Gy, onde aos 60Gy, no esmalte, os prismas se tornaram amorfos e a camada interprismática degradada, e na dentina os túbulos dentinários encontravam-se completamente obliterados; na análise da interface adesiva do grupo 2 notou-se que quase não houve formação de tags e nos grupos 3 de esmalte a camada adesiva formada era mais fina, porém com formação de tags mais prolongados e na dentina houve formação de gaps. / Head and neck cancer is among all kinds of cancer the seventh most common and radiotherapy (RT) is one of its main treatments, which is widely used and efficient, but side effects are unavoidable. A dental treatment before RT is very important to reduce/eliminate infectious foci in the oral cavity, so it is essential to eliminate carious lesions, and after RT \"radiation caries\", which are a side effect of the treatment, must be eliminated. Adhesive systems are the most indicated to restore teeth of patients undergoing RT, so this study aimed to evaluate in vitro the effect of RT in the moment of the dental restorations in enamel and dentin, using shear bond strength tests, evaluate morphologic alterations at teeth surface during RT, with a laser confocal microscopy and to evaluate qualitatively the union interface of the composite/ dental substrate by scanning electron microscope (SEM). It was used 60 third molars, which were sectioned into 120 fragments of enamel and 120 of dentin, and after the surface prepare the specimens were randomly divided into 4 groups (n=30): G1 (control) - no irradiated substrate + restorative procedure; G2 - restorative procedure performed before RT; G3 - restorative procedure performed after RT; e G4 - restorative procedure performed 6 months after RT. Each group was divided into 2 subgroups: Subgroup \"A\" (SGA) in which was used the AdperTM Single Bond 2 (SB); and subgrup \"B\" in which was used Clearfil SE Bond (CL), for the restorative procedure. The specimens were fractionally irradiated by a dose of 2Gy/day, 5 consecutive days, until it reached a total dose of 60Gy, in a total of 30 fractions, lasting 6 weeks. For the restorative treatment the resin Z350 was chosen, and for standardization it was used a matrix so all specimens had 4mm height and 2mm in diameter. The specimens were submitted to shear bond strength test and the fracture pattern was evaluated. It was chosen 5 specimens of each substrate for the morfological evaluation of the dental surface by a laser confocal microscopy, those were evaluate every 10Gy. To evaluate the adhesive interface it was chosen 3 specimens of each group and those were prepared for the SEM. A better performance was observed for the CL, in both dental substrates, rather than the SB; according to the period of restoration, in both enamel and dentin, Group 2 has showed lower values; the predominant fracture pattern to all groups was the Adesive one; there were morphological alterations in enamel and dentin after a cumulative dose of 30Gy, the prisms of enamel became formless and the interprismatic region was degraded after 60Gy, at the dentin the dental tubules were completely amorphous; the analysis of the interface adhesion has showed that in group 2 tags were barely formed, and in group 3 of enamel the adhesive layer was thinner, but tags were longer, and at the dentin gaps were observed.
302

Microtração de sistemas adesivos autocondicionantes em dentina desmineralizada de dentes decíduos após preparo cavitário com laser de Er: YAG: avaliação in vitro / Microtensile bond strength of selfetch adhesive systems in demineralised dentin of primary teeth after Er: YAG laser irradiation: in vitro evaluation

Cintia Guimaraes de Almeida 01 June 2011 (has links)
O objetivo deste estudo foi avaliar a resistência à microtração de adesivos autocondicionantes em dentina desmineralizada de dentes decíduos após a irradiação com laser de Er: YAG. Oitenta e dois molares decíduos tiveram a porção oclusal seccionada transversalmente e os espécimes foram desgastados com lixas de carbeto de silício de granulações 360 e 600 até expor a dentina. Os 60 espécimes utilizados no teste de microtração foram preenchidos com resina composta fotopolimerizável na região correspondente à câmara pulpar, isolados com esmalte cosmético mantendo a superfície dentinária exposta e, em seguida imersos em solução desmineralizante por seis dias em estufa a 37° C para indução de lesão de cárie artificial em dentina. Após a desmineralização, os espécimes foram preparados com laser de Er: YAG (n=30) com os parâmetros de 260 mJ, 3 Hz, 47 J/cm2, 0,81W e com broca de aço esférica em baixa rotação (n=30). Sobre as superfícies preparadas foram aplicados três sistemas adesivos autocondicionantes Clearfil SE Bond (Kuraray); Adper™ Easy One (3M ESPE) e Adper™ SE Plus (3M ESPE) e, em seguida foram confeccionados platôs de resina composta Z 250. Após termociclagem (500 ciclos), os corpos de prova foram seccionados produzindo palitos de aproximadamente 1 mm2 de área transversal, que foram submetidos ao teste de microtração e os valores obtidos foram analisados estatisticamente através de ANOVA e teste de Duncan (5%). A análise qualitativa dos tipos de fraturas foi realizada por meio de lupa estereoscópica (aumento de 40X) e da interface adesiva por meio de MEV. Para a análise química da dentina através de espectroscopia no infravermelho por transformada de Fourier (FTIR), foram utilizados discos de dentina após o preparo superficial com a broca (n=5) e com o laser (n=5), e comparadas com as análises de tecido dentinário sadio e desmineralizado obtidas dos mesmos espécimes. Os resultados foram submetidos ao teste estatístico t−Student (5%). O teste de microtração demonstrou que houve diferença significativa entre os adesivos, sendo que o grupo controle (Clearfil e broca) obteve o melhor desempenho comparativamente a todos os grupos avaliados. O preparo com laser de Er: YAG afetou adversamente a adesão para os sistemas adesivos Clearfil SE Bond e Adper™ Easy One em comparação com os grupos preparados com broca. Nos grupos irradiados com laser, o sistema adesivo Clearfil SE Bond foi o que proporcionou o maior valor médio de microtração. Os resultados da FTIR demonstraram que, com a irradiação da dentina desmineralizada, houve um decréscimo na quantidade de matéria orgânica e de carbonato em relação ao grupo da dentina sadia. No substrato preparado com broca, observouse aumento da matéria orgânica e redução de carbonato. Concluise que, em relação aos sistemas adesivos, o Clearfil SE Bond teve o melhor desempenho no teste de resistência à microtração em dentina de dentes decíduos. A irradiação com laser de Er: YAG afetou adversamente a adesão dos sistemas adesivos Clearfil SE Bond e Adper™ Easy One. A irradiação com laser de Er:YAG decresceu de maneira significativa a quantidade de matéria orgânica presente na dentina de dentes decíduos. / The purpose of this study was to evaluate the microtensile bond strength of three selfetch adhesives systems to demineralized dentin of primary teeth after irradiation with Er: YAG laser. Eighty two primary molars had the occlusal enamel sectioned and the specimens were grounded with silicon carbide sandpaper grits of 360 and 600 to expose the dentin. The 60 specimens used in the microtensile test were filled with composite resin in the region corresponding to the pulp chamber, insulated with nail varnish keeping the exposed dentin surface and then immersed in demineralizing solution for six days in a stove at 37 Celsius degrees in order to produce artificial carieslike lesions in dentin. After demineralization, the specimens were prepared with Er: YAG (n = 30) using as parameters 260 mJ, 3 Hz, 47 J/cm2, 0.81 W and a round steel drill at low speed (n = 30 ). On the prepared surfaces were applied three self−etch adhesives systems Clearfil SE Bond (Kuraray); Adper™ Easy One (3M ESPE) and AdperTM SE Plus (3M ESPE) and then plateaus of composite resin Z 250 were built up. After thermocycling (500 cycles), specimens were sectioned to produce multiple sticks of approximately 1 mm2 crosssectional area, which were subjected to microtensile test and the data were analyzed with ANOVA and Duncan test at a significance level of 0.05. The qualitative analysis of the types of fractures was performed using a stereomicroscope (X40 magnification) and the morphological analyses of adhesive interfaces were performed by scanning electron microscopy (SEM). Chemical analysis of the dentin by Fourier transform infrared spectroscopy (FTIR) were performed in dentin discs after surface preparation with the steel drill (n = 5) and laser (n = 5) and compared with the values previously obtained from the analysis of sound and demineralized dentin tissue in the same specimens. The results were analyzed by Student\'s t−test at a significance level of 0.05. Regarding the microtensile bond strength there was a significant difference between the adhesive systems, and the control group (Clearfil and steel drill) had the best performance compared to all groups. Er: YAG laser irradiation adversely affected bond strength to the Clearfil SE Bond and Adper™ Easy One compared with the groups prepared with steel drill. In the laser groups Clearfil SE Bond reached the highest average bond strength. Results of FTIR analysis showed that the hydration of dentin remained normal after both preparations. With laser irradiation of demineralized dentin there was a decrease in the amount of organic matter and carbonate in relation to the group of sound dentin. The analyses of substrate prepared with steel drill showed an increase in organic matter and reduction of carbonate. The conclusion in relation to adhesive systems was that Clearfil SE Bond had the best performance in microtensile bond strength in primary teeth dentin. Laser irradiation adversely affected the bond strength of Clearfil SE Bond and Adper™ Easy One selfetch adhesive systems. Laser irradiation had significantly reduced the organic matter content in dentin of deciduous teeth.
303

Resistência ao cisalhamento de selante associado a dois sistemas adesivos, após contaminação salivar: influência da fotopolimerização individual e simultânea / Shear bond strength of a pit-and-fissure sealant associated with two adhesive systems after salivary contamination: influence of individual and simultaneous light curing

Jaciara Miranda Gomes da Silva 06 August 2007 (has links)
Este trabalho teve por objetivo avaliar \"in vitro\" a resistência ao cisalhamento de um selante resinoso (Fluroshield - F) em associação com um sistema adesivo total-etch (Adper Single Bond 2-SB) e um self-etching (Clearfil S3 Bond-S3) em condições de contaminação salivar, comparando dois protocolos de fotopolimerização: individual do sistema adesivo e, em seguida, do selante ou simultânea de ambos materiais conjuntamente. Superfícies mesiais e distais de 45 terceiros molares humanos hígidos foram incluídas e planificadas, o sítio de adesão delimitado (Ø 3mm) e os corpos-de-prova alocados aleatoriamente em 6 grupos experimentais (n=15), de acordo com o tratamento empregado: I- F aplicado sobre o esmalte condicionado com ácido fosfórico a 37% (controle). Os demais grupos foram contaminados com saliva (0,01ml por 10 s) e a seguir foram aplicados: II- SB e F fotopolimerizados separadamente; III- SB e F fotopolimerizados conjuntamente; IVS3 e F fotopolimerizados separadamente; V- S3 e F fotopolimerizados simultaneamente; VI- F aplicado sem associação com adesivos sobre o esmalte condicionado e contaminado. A seguir, um cilindro de selante foi confeccionado com o auxílio de uma mesa metálica e de matriz de teflon bipartida sobre o sítio de adesão. Após armazenamento durante 24 horas a 37°C em água destilada, os espécimes foram submetidos ao teste de resistência ao cisalhamento em Máquina de Ensaios Universal (0,5mm/min; 50Kgf). As interfaces adesivas foram analisadas quanto ao tipo de fratura em microscópio óptico com 20x de aumento e para análise qualitativa, três espécimes de cada grupo, foram selecionados e analisados em microscópio eletrônico de varredura. As médias obtidas, em MPa, e os desvios padrão foram: I-12,28 (±4,29); II-8,57 (±3,19); III-7,97 (±2,16); IV-12,56 (±3,11); V- 11,45 (±3,77); e VI-7,47 (±1,99). A análise estatística, por meio da Análise de Variância e teste de Fisher, demonstrou que a contaminação salivar afetou negativamente a resistência adesiva. A associação do sistema adesivo self-etching ao selante resultou em uma média semelhante estatisticamente ao grupo controle. Comparando os protocolos de fotopolimerização, não houve diferença estatisticamente significante entre os grupos nos quais foi realizada a fotopolimerização simultânea ou individual dos materiais. Com base nestes resultados pôde-se concluir que o protocolo de fotopolimerização não afetou os valores de resistência adesiva ao esmalte condicionado e contaminado. A associação do sistema adesivo self-etching Clearfil S3 Bond ao selante Fluroshield aumentou a resistência ao cisalhamento com diferença estastísticamente significante em relação aos grupos nos quais foi utilizado o sistema adesivo Adper Single Bond 2 e com valor médio semelhante ao grupo controle, no qual o selante foi aplicado em condições ideais, na ausência de contaminação salivar. / The purpose of this study was to evaluate in vitro the shear bond strength of a resin-based pit-and-fissure sealant (Fluroshield - F) associated with a total-etch (Adper Single Bond 2 - SB) and a self-etching adhesive system (Clearfil S3 Bond - S3) under conditions of salivary contamination, comparing two curing protocols: individual light curing of the adhesive system and the sealant or simultaneous curing of both materials. Mesial and distal surfaces from 45 sound third molars were embedded, flattened and a 3-mm-diameter bonding site was demarcated. The specimens were randomly assigned to 6 experimental groups (n=15), according to the bonding technique: I - F was applied to the enamel etched with 37% phosphoric acid. The other groups were contaminated with saliva (0.01 mL during 10 s). II - SB and F were light cured separately; III - SB and F were light cured together; IV - 3S and F were light cured separately; V - 3S and F were light cured simultaneously; VI - F was applied to salivary-contaminated etched enamel without an intermediate bonding agent layer. Thereafter, a sealant cylinder was fabricated using a metallic clamping device and a split Teflon matrix placed over the bonding site. After 24-hour storage in distilled water at 37°C, shear bond strength was measured using a knifeedge blade in a universal testing machine (0.5 mm/mm; 50 kgf). The debonded interfaces were examined with an optical microscope to determine the failure modes. For a qualitative analysis, 3 specimens from each group were selected and observed under scanning electron microscopy. Means (±SD) in MPa were: I-12,28 (±4,29); II 8,57 (±3,19); III-7,97 (±2,16); IV-12,56 (±3,11); V-11,45 (±3,77); and VI-7,47 (±1,99). Statistical analysis by ANOVA and Fisher\'s test showed that salivary contamination affected negatively the bond strength. The association between the self-etching adhesive system and sealant yielded bond strength mean statistically similar to that of the control group. Comparing the curing protocols, there was no statistically significant difference between the groups with simultaneous or individual light curing of the materials. Based on these results, it may be concluded that the curing protocol did not affect the bond strength to the contaminated etched enamel. The association of Clearfil S3 Bond self-etching adhesive system to Fluroshield sealant increased the shear bond strength with statistically significant difference from the groups with Adper Single Bond 2 adhesive system, and showing mean value similar to that of the control group, in which the sealant was applied under ideal conditions, without salivary contamination.
304

Efeito de um agente primer e de ciclos térmicos para cocção de porcelana na resistência de união adesiva entre alumina e cimento resinoso / Effect of a primer agent and thermal cycles for porcelain firing on the bond strength of resin cement to alumina.

Carvalho, Renato Savi de 11 September 2009 (has links)
Coroas cerâmicas apoiadas sobre infra-estruturas de alumina densamente sinterizada configuram-se como excelentes opções para a reabilitação protética em casos de exigência estética, contudo, o aumento do conteúdo cristalino inviabiliza seu condicionamento por ácidos deixando a maneira ideal de cimentá-las ainda desconhecida. Coroas Procera AllCeram apresentam, em sua face interna, micro irregularidades interessantes ao embricamento e adesão resinosa, dispensando manobras de condicionamento. Objetivo: O objetivo deste trabalho foi avaliar a influência de elevadas temperaturas (500ºC à 950ºC) necessárias à cocção da porcelana de revestimento, na textura superficial da alumina, bem como o papel de um agente primer (Ivoclar Vivadent) na força de adesão entre alumina e cimento resinoso. Material e métodos: Sessenta (60) cilindros de alumina (3,5mm X 16mm) com rugosidade superficial idêntica à dos copings Procera foram divididos em quatro grupos (n=15). Grupo 1): Espécimes não submetidos a variação térmica, sendo G1a Sem aplicação do primer e G1b Com aplicação do primer e Grupo 2): Espécimes submetidos aos ciclos térmicos para cocção da porcelana feldspática, sendo G2a Sem aplicação do primer e G2b Com aplicação do primer. Sobre os cilindros aplicou-se porção do cimento resinoso químico MultiLink Ivoclar. Os espécimes foram levados a uma máquina de ensaios Universal para teste de cisalhamento a uma velocidade de 0.5mm/min e os dados submetidos à análise de variância a um critério e teste de comparações múltiplas de Tukey. Resultados: A força de adesão para cada um dos grupos foi: G1a = 2.468 MPa; G1b = 4.265 MPa; G2a = 2.339MPa e G2b = 4.185 MPa. Diferenças significantes foram observadas entre os grupos: G1a X G1b; G1a X G2b; G1b X G2a e G2a X G2b. Conclusões: Ciclos térmicos não produziram alterações na micro-estrutura superficial da alumina, tampouco comprometeram sua adesão ao cimento. O agente primer aumentou a força de união entre alumina e cimento resinoso. Fraturas coesivas do agente cimentante foram observadas apenas em alguns espécimes primer-tratados. / High-strength alumina based ceramic crowns are widely used in dentistry due to their favorable esthetic, however, the large amount of crystalline contents jeopardizes their acid etching property and the ideal luting remains unclear. Procera AllCeram restorations exhibits on their intaglio surface micro irregularities optimizing the bonding to resin, with no need for additional conditioning procedures. Purpose: The aim of the present study was to evaluate the influence of high thermal cycles (500ºC to 950ºC) needed to porcelain firing on alumina´s intaglio surface, as well as, the role of a primer agent (Ivoclar Vivadent) on shear bond strength between alumina and resin cement. Material and Methods: Sixty alumina cylinders (3,5mm X 16mm) with intaglio roughness of the Procera AllCeram copings were randomly divided into four groups (n=15). Group 1) Samples no submitted to thermal cycles variation, were G1a - no primer application and G1b - primer treated and Group 2: Samples submitted to thermal feldspathic porcelain firing cycles, were G2a - specimens no primer treated and G2b - primer treated specimens. Over the cylinders top a self-cure resin cement (Multilink Ivoclar) portion was applied. The specimens were loaded to failure in shear mode using a universal testing machine at a crosshead speed of 0,5mm/min. Data were analyzed with one-way analysis of variance and Tukey´s multiple comparison test. Results: The shear bond strength for each group was: G1a = 2.468 MPa; G1b = 4.265 MPa; G2a = 2.339 MPa e G2b = 4.185 MPa. Significant difference was found between the groups G1a X G1b; G1a X G2b; G1b X G2a e G2a X G2b. Conclusions: Thermal cycles did not change alumina´s surface micro structure, besides did not compromised it´s bonding strength to resin cement. Primer agent enhanced shear bond strength between alumina and resin cement. Luting agent´s cohesive fractures were observed only in some primer treated specimens.
305

Influência de adesivos autocondicionantes na resistência adesiva de cimentos de ionômero de vidro resinomodificados à dentina / Influence of self-etch adhesive on bond strength of resin-modified glass ionomer to dentin

Menegatti, Giovanna Emann Tavares 12 May 2016 (has links)
A presente pesquisa se propôs a avaliar a influência de cinco tratamentos dentinários na resistência de união à dentina de quatro cimentos de ionômero de vidro modificados por resina (CIVRMs). O ensaio experimental foi realizado in vitro, fazendo uso de 200 incisivos bovinos. Destes, foram obtidos 200 fragmentos de dentina, que foram distribuídos aleatoriamente em 20 grupos (n=10), segundo os fatores de variação que compreendem cinco tratamentos dentinários (Grupo controle, ou seja, sem tratamento; Ácido Poliacrílico a 20%, Clearfil SE Bond; Single Bond Universal e Primer do Vitremer) e quatro cimentos ionoméricos (GC Fuji II LC® CAPSULE; GC Fuji LINING® LC (Paste Pak); Vitrebond® e Vitremer). Após a confecção dos corpos de prova e 24h de armazenamento em estufa à 37oC, foi realizado o teste de microcisalhamento na máquina de ensaios universal (Instron 5942 - Canton, MA, EUA) com velocidade de 1mm/min, seguido da análise do padrão de fratura em microscópio digital. A análise estatística dos 400 resultados obtidos foi feita por meio do teste paramétrico ANOVA para dois fatores de variação (cimento e tratamento) (p<0,05%) e pelo teste auxiliar de Tukey (p<0,05%). Os testes estatísticos demonstraram haver diferença estatística tanto entre os tratamentos, como entre os cimentos e na interação de ambos (p<0,0001). Os sistemas adesivos Clearfil SE (X?=18,26 ± 2,78) e SingleBond (X?=17,28 ± 2,49) promoveram os valores de resistência adesiva mais elevados em comparação aos demais tratamentos, mas sem apresentarem diferença estatística entre si, o que representou um aumento na resistência de união de 121% para o Clearfil SE e 109,2% para o Single Bond Universal em relação ao Grupo Controle. O uso do Ácido Poliacrílico (X?=9,94 ± 3,55) alcançou valores intermediários, correspondendo a um aumento de 20% na resistência adesiva em relação ao Grupo Controle. Esse tratamento se diferenciou estatisticamente dos maiores valores, porém não apresentou diferença frente ao Primer do Vitremer (X?=8,91 ± 2,97). O grupo controle (X?=8,26 ± 4,17) evidenciou os menores valores, se diferenciando estatisticamente dos sistemas adesivos e do Ácido Poliacrílico, mas com resultados que o equiparou ao tratamento com o Primer do Vitremer. Ao se analisar a interação entre cimento e tratamento, todos os cimentos de ionômero de vidro resinomodificados (CIVRMs) testados neste estudo apresentaram seus maiores resultados quando um dos sistemas adesivos foi utilizado como tratamento dentinário, independente de qual sistema adesivo. Com base nesses resultados, pôde-se concluir que os dois sistemas adesivos autocondicionantes foram capazes de melhorar significativamente a resistência adesiva dos CIVRMs. / This research aims to evaluate the influence of five dentin pretreatments on microshear bond strength of four resin-modified glass ionomer (RMGI). The experiment was performed in vitro, using 200 bovine incisors. From these, there were obtained 200 dentine fragments that were randomly distributed into 20 groups (n = 10) according to the variation factors comprising five dentin treatment (control group, i.e., no treatment; Polyacrylic Acid 20%; Clearfil SE Bond; Single Bond Universal and Vitremer Primer) and four glass ionomer cements (GC Fuji II LC® CAPSULE; GC Fuji LC LINING® (Paste Pak); Vitrebond® and Vitremer). After preparation of the samples and 24h storage at 37 °C, was performed microshear test in a universal testing machine (Instron 5942 - Canton, MA, USA) with speed of 1mm/min, followed by analysis of the pattern fractures in digital microscope. Statistical analysis of the 400 results was performed by ANOVA nonparametric test for two variation factors (cement and treatment) (p <0.05%) and the post-hoc Tukey (p <0.05%). The tests demonstrated there are statistical difference between treatments, cements and between the interaction of both (p <0.0001). The Clearfil SE (X?=18,26 ± 2,78) and SingleBond (X?=17,28 ± 2,49) promoted the highest bond strength values compared to the other treatments, but showing no statistical difference between them, which represented an increase in bond strength of 121% for Clearfil SE and 109.2% for Single Bond Universal compared to control group. The Polyacrylic Acid (X?=9,94 ± 3,55) has reached intermediate values, corresponding to a 20% increase in adhesive strength compared to control group. This treatment differed significantly from the higher values, but showed no difference compared to Primer Vitremer (X?=8,91 ± 2,97). The control group (X?=8,26 ± 4,17) showed the lowest values, statistically differing from the adhesives and polyacrylic acid, but with results that matched to the treatment with Vitremer Primer. When analyzing the interaction between cement and treatment, all cements tested in this study had higher results when one of the adhesive systems was used as dentin treatment, regardless of which adhesive system. Based on these results, it could be concluded that the two adhesive systems were able to significantly improve the adhesive strength of RMGIs.
306

"Avaliação de cerâmicas odontológicas quanto à resistência de união com a dentina, por ensaio de tração, microdurezas Knoop e Vickers, rugosidade superficial e microscopia de força atômica" / Evaluation of dental ceramics regarding tensile bond strength to dentin, Knoop and Vickers’ microhardness, surface roughness and atomic force microscopy

Martuci, Ricardo Ruiz 01 June 2006 (has links)
Foram ensaiadas quatro cerâmicas VMK 95, Omega 900, IPS d. Sign e Cergogold. Os ensaios realizados foram: 1) resistência de união, por ensaio de tração, à dentina humana, de cones (6 x 3 x 5mm) de cerâmica, unidos por meio de cimentos fosfato de zinco, resinosos Rely X e Panávia F (n=10); 2) rugosidade pelos parâmetros Ra, Rt, Ry, Rz e Rp, de superfícies tratadas com ácido fluorídrico a 10% e polidas (n=10); 3) durezas Knoop e Vickers (n=4); 4) análise por microscopia de força atômica de superfícies polidas apenas (n=5). Os dados foram analisados pela análise de variância e testes de Tukey foram feitos quando necessário. A resistência de união com o fosfato de zinco e o parâmetro de rugosidade Ra foram analisados em separado, por apresentarem variâncias bem menores que as correspondentes aos demais agentes cimentantes e parâmetros. Os resultados mostraram que a resistência de união com o fosfato de zinco foi muito baixa (1,61 a 2,91MPa), nas condições dos ensaios. Com cimentos resinosos a resistência média variou de 16,61 a 18,47MPa. O cimento Rely X apresentou menor resistência em média, mas isto também depende da cerâmica.As rugosidades das superfícies tratadas com ácido fluorídrico a 10% foram bem maiores do que nas polidas. Nessas o parâmetro Ra variou de 2,15 a 4,26µm e os demais parâmetros de 10,99 a 21,93µm. Nas superfícies polidas o Ra variou de 0,53 a 0,84µm. Os demais parâmetros apresentaram médias de 2,01 a 5,23µm. A dureza Knoop variou de 418,9 a 493,8 kgf/mm2 e a Vickers de 492,5 a 572,2 kgf/mm2. Esta última apresentou valores maiores. A microscopia de força atômica permitiu visualizar irregularidades de superfícies. As principais conclusões foram: o cimento de fosfato de zinco, na condição do ensaio (por tração) apresentou resistência de união muito baixa; com os cimentos resinosos a resistência de união foi bem alta; as rugosidades foram muito altas após o tratamento superficial com ácido fluorídrico a 10%, mas, as polidas apresentaram valores bem baixos; as durezas Vickers fornecem valores maiores que a Knoop. / Four ceramics (VMK 95, Omega 900, IPS d.Sign and Cergogold) were tested regarding: 1) tensile bond strength to human dentin of ceramic cones (6 x 3 x 5mm), cemented with zinc phosphate, and resin cements, Rely X and Panávia F (n=10); 2) roughness by means of parameters Ra, Rt, Ry, Rz and Rp, of HF (10%) surface treated and polished surfaces (n=10); 3) Knoop and Vickers hardness (n=4); 4) atomic force microscopy; only of polished surfaces (n=5). Data were analyzed by ANOVA and when necessary were used Tukey’s tests. Tensile bond strength with zinc phosphate cement and Ra roughness parameter were analyzed separately because of their low variances when compared with those of resin cements and the other roughness parameter. Results showed that tensile bond strength of zinc phosphate was very low (1.61 to 2.91MPa) in this test condition (tensile test). Resin cements presented tensile bond strength at range 16.61 to 18.47MPa. Cement Rely X presented lower strength, but it depends also of ceramic. HF (10%) treated surfaces presented much higher roughness than polished ones. In HF (10%) treated surfaces parameter Ra ranged from 2.15 to 4.26µm and the other parameter ranged from 10.99 to 21.93µm. Roughness of polished surfaces Ra ranged from 0.53 to 0.84µm. Range of the other parameter was from 2.01 to 5.23µm. Knoop hardness ranged from 418.9 to 493.8 kgf/mm2 and Vicker’s from 492.5 to 572.2 kgf/mm2. This type presented higher values. Atomic force microscopy permited good vision of surface irregularities. Main conclusions were: zinc phosphate cement at test conditions (tensile) presented low bond strength; resin cements presented high tensile bond strength; surface treatment with HF (10%) led to high roughness but in polished one it was low; Vicker’s hardness presented higher values than Knoop one.
307

Resistência de união de cimentos resinosos à dentina previamente submetida a radioterapia / Bonding strength of resin cements to the dentin previously submitted to radiotherapy

Yamin, Paulo André 02 February 2017 (has links)
Este estudo avaliou, in vitro, a influência da radioterapia na resistência de união (RU) e na interface adesiva entre diferentes cimentos resinosos e dentina radicular. Sessenta caninos superiores foram distribuídos em 2 grupos (n=30) de acordo com a irradiação: não irradiados e irradiados. Os dentes do grupo irradiado foram submetidos à radioterapia com raios-X de 6 MV em frações de 2 Gy, com 30 ciclos, perfazendo 60 Gy. Os dentes foram seccionados para obtenção de raízes com 16 mm de comprimento, sendo realizado em seguida o preparo biomecânico com instrumento Reciproc R50 e obturação pela técnica de condensação lateral com cimento a base resina epóxica. Cada grupo foi subdividido de acordo com o cimento resinoso utilizado para a cimentação dos pinos de fibra de vidro (n=10): RelyX U200; Panavia F 2.0; RelyX ARC. Os pinos foram submetidos a tratamento de superfície com ácido fluorídrico 10% e cimentados de acordo com as recomendações de cada fabricante. Após a cimentação dos pinos, os dentes foram seccionados transversalmente em slices de 1 mm de espessura, obtendo-se 3 slices de cada terço da raiz. Os slices mais cervicais de cada terço foram utilizados para avaliar a RU, por meio do teste de push-out com velocidade de 0,5 mm/min, e posterior análise do padrão de falha em estereomicroscópio. Os slices mais apicais de cada terço foram selecionados para análise da interface cimento/dentina em MEV com aumentos de 100, 1000, 2000 e 4000X. Os dados de RU e adaptação da interface cimento/dentina foram submetidos à análise estatística pelos testes de ANOVA e Tukey, e Kruskal-Wallis e Duns, respectivamente. Os espécimes irradiados apresentaram menores valores de RU (8,23&plusmn;4,26) comparados aos dentes não irradiados (11,88&plusmn;6,42) (p<0,00001). Quanto aos cimentos resinosos, o RelyX U200 apresentou maiores valores na RU (15,17&plusmn;5,89) comparado aos cimentos RelyX ARC (7,68&plusmn;4,22) (p<0,0001) e Panavia F 2.0 (7,32&plusmn;2,71) (p<0,0001). O terço cervical apresentou maiores valores de RU (13,08&plusmn;6,10) comparado aos terços médio (9,72&plusmn;5,03) e apical (7,38&plusmn;4,53) (p<0,0001). O padrão de falhas mostrou ocorrência de falhas coesivas na dentina para os espécimes irradiados. Na análise da interface cimendo/dentina por MEV, observou-se maior desadaptação nos dentes submetidos à radioterapia. Em relação aos cimentos resinosos, foi observada maior adaptação com RelyX U200 e RelyX ARC comparados à Panavia F 2.0. Na análise qualitativa em MEV observou-se presença de fraturas e microfraturas na dentina radicular e menor presença de fibras colágenas em dentes irradiados. Para o cimento resinoso RelyX U200 e Panavia F 2.0 observou-se interface justaposta do cimento com a dentina radicular em dentes irradiados e não irradiados, sendo que para o cimento resinoso RelyX ARC foi observada formação de camada híbrida e tags de maneira similar para dentes irradiados e não irradiados. Concluiu-se que a radioterapia resultou na redução da resistência de união e na maior desadaptação da interface cimento resinoso/dentina radicular e que o cimento resinoso autoadesivo se apresentou como melhor alternativa para cimentação de pinos de fibra de vidro em dentes irradiados. / This in vitro study, evaluated the influency of radiotherapy on bond strength (BS) and adhesive interface between different resin cements and root dentin. Sixty maxillary canines were selected and distributed into two groups (n = 30) according to the irradiation protocol: non-irradiated and irradiated. The irradiated group were submitted to X-ray radiotherapy of 6 MV in fractions of 2 Gy, with 30 cycles, until complete 60 Gy. The teeth were sectioned to obtain 16 mm of root length, followed by biomechanical preparation with R50 reciproc instrument and obturation using the lateral condensation technique with epoxy resin-based sealer. Then, each group was subdivided according to the resin cement used for the glass fiber post cementation (n = 10): RelyX U200, Panavia F 2.0 and RelyX ARC. The posts were submitted to surface treatment with 10% hydrofluoric acid, and then cemented according to the manufacturer instructions. After the posts cementation, the teeth were sectioned transversely into 1 mm thick slices, and 3 slices were obtained from each root third. The most cervical slice of each third was used to evaluate the BS by the push-out test at 0.5 mm/min of velocity and the failure pattern was analyzed using stereomicroscopy. The most apical slice of each third was selected for SEM analysis, which were prepared and metalized. The dentin/cement interface analysis was performed at the following magnification: 100, 1000, 2000 and 4000X. The BS data and dentin/cement interface adaptation were submitted to statistical analysis by ANOVA, Tukey and Kruskal-Wallis, and Duns tests respectively. The irradiated specimens had lower BS values (8.23 &plusmn; 4.26) compared to non-irradiated group (11.88 &plusmn; 6.42) (p <0.00001). Regarding the resin cements, the RelyX U200 showed the higher values in BS (15.17 &plusmn; 5.89) compared to RelyX ARC (7.68 &plusmn; 4.22) and Panavia F 2.0 (7 , 32 &plusmn; 2.71) (p <0.0001). In addition, the cervical third presented higher BS values (13.08 &plusmn; 6.10) when compared to the middle (9.72 &plusmn; 5.03) and apical (7.38 &plusmn; 4.53) thirds (p <0.0001). The failure pattern showed cohesive failures in root dentin of the irradiated specimens. In the SEM dentin/cement interface analysis, a greater misadaptation was observed for the teeth submitted to radiotherapy. Regarding the resin cements, a better adaptation was observed for the RelyX U200 and RelyX ARC compared to the Panavia F 2.0. In the SEM qualitative analysis of the irradiated teeth, was possible to observe the presence of fractures and microfractures in the root dentin and a small number of collagen fibers. The resin cements RelyX U200 and Panavia F 2.0 showed a juxtaposed interface of the cement with the root dentin in irradiated and non-irradiated teeth, being that for the RelyX ARC cement the presence of hybrid layer and tags was similar for irradiated and non-irradiated groups. It was concluded that the radiotherapy promoted reduction of the bond strength and increase the gaps in the dentin/resin cement interface and the self-adhesive resin cement is the best alternative for glass fiber posts cementation in irradiated teeth.
308

Influência de variáveis metodológicas no valor da resistência de união material adesivo/substrato dentinário e, no padrão de fratura: ensaio de \"micro\" cisalhamento / Methodological variables influence on bonding of adhesive material/dentin substrate and fracture pattern micro shear test

Andrade, Andréa Mello de 10 December 2010 (has links)
A influência de variáveis metodológicas no valor da resistência de união e no padrão de fratura, por ensaio de microcisalhamento, foi verificada em dentina planificada de molares humanos e estudada em quatro diferentes experimentos, nos quais dois sistemas adesivos foram utilizados (Adper Single Bond 2 e XP Bond) e uma resina composta (Filtek Z250). Foram eles: Experimento 1- momento de fotoativação do adesivo: antes ou após o posicionamento das cânulas sobre o substrato dentinário; Experimento 2- tempo de armazenagem: 10min, 24 horas, 48 horas e 7 dias em água destilada a 37oC; Experimento 3- área de secção transversal dos corpos de prova: 0,44mm2, 0,82mm2, 1,98mm2 e 4,44mm2; Experimento 4- momento de fotoativação da resina / remoção da cânula para o ensaio. Os dados obtidos de resistência de união, em MPa, foram tratados por métodos de ANOVA. Os corpos de prova resultantes de todos os experimentos foram observados em microscopia eletrônica de varredura e analisados de forma qualitativa quanto ao modo de fratura. Houve diferença significativa no Experimento 1, sendo que os valores médios de resistência de união foram mais altos quando os adesivos foram fotoativados antes de posicionar as cânulas. Não houve diferença estatisticamente significante para as variáveis tempo de armazenagem e sistema adesivo (Experimento 2), e nem para as variáveis área de secção transversal e sistema adesivo estudadas (Experimento 3). Para o Experimento 4, houve diferença estatisticamente significante para a condição experimental resina fotoativada e remoção da cânula quando previamente realizada à adesão ao substrato e entre os adesivos. Em todos os experimentos o modo de fratura foi predominantemente adesivo/misto. Concluiu-se que algumas variáveis do método são fundamentais para sua padronização, pois com base nos resultados deste estudo elas influenciam os valores médios da resistência de união. / The effect of methodological variables on the microshear bond strength and fracture pattern was assessed in flat human molars dentin in four different experiments using two adhesive systems (Adper Single Bond 2 and XP Bond) and a composite resin (Filtek Z250). The experiments were: 1. Adhesive light activation moment prior or after mold positioning on dentin; 2. Storage period 10 min, 24h, 48h or 7 days in distilled water at 37oC; 3. Mold transversal section area 0.44mm2, 0.82mm2, 1.98mm2 and 4.44mm2; 4. Resin light activation moment with or without mold removal prior to testing. Mean data values (MPa) were subjected to ANOVAs methods. All fractured specimens were qualitatively analyzed in SEM to verify the fracture mode. Regarding Experiment 1 a significative difference was shown for the main factor Adhesive Light Activation Moment; higher bond strength values were achieved with adhesive system ligth activated before mold positioning. No significant differences were found for storage period or section area analyzed on Experiments 2 and 3, respectively. The main factor Resin Light Activation Moment presented differences when the resin composite was previously light activated and mold was removed prior to bonding the resin with the adhesive systems. In all experiments, mode of failure was predominantly adhesive/mixed. The conclusion is that some variables of the method are essential for its standardization, given that they influence the bond strength values.
309

Influência do sistema de cimentação e do modo de ativação na resistência ao push-out de pinos de fibra de vidro / Influence of cementation system and activation mode on push-out bond strength of glass fiber posts

Reinaldo de Souza Ferreira 04 December 2009 (has links)
O objetivo deste estudo foi avaliar a influência do tipo de sistema de cimentação (condicionamento ácido total ou autoadesivo), do modo de ativação (autoativado ou dual), do terço do conduto radicular (cervical, médio ou apical) e da espessura do filme de cimento sobre a resistência de união de pinos de fibra de vidro cimentados em dentes humanos. Quarenta raízes foram incluídas em resina epóxi, submetidas a tratamento endodôntico e obturadas com guta percha e cimento endodôntico sem eugenol. Decorridos sete dias, os condutos foram preparados a uma profundidade de 10mm com brocas padronizadas do sistema dos pinos de fibra (WhitePost DC #2) e aleatoriamente divididos em 4 grupos, conforme o sistema de cimentação e o modo de ativação: (G1) RelyX ARC/Adper Scotchbond Multi-Purpose Plus (condicionamento ácido total), ativação dual, (G2) RelyX ARC/Adper Scotchbond Multi-Purpose Plus, autoativado, (G3) RelyX U100 (autoadesivo), dual e (G4) RelyX U100, autoativado. Após uma semana, cada raiz foi seccionada em máquina de corte, originando 6 fatias de 1 mm de espessura (n=60). Antes do ensaio de push-out cada fatia foi fotografada em ambas as faces, para determinação do raio dos pinos e da espessura do filme de cimento. Após o ensaio mecânico, novas imagens foram capturadas para determinação do modo de falha. Para automatizar a determinação da espessura de cimento, foi desenvolvida uma macro no software KS 400. Os dados foram estatisticamente analisados com ANOVA 3 fatores (resistência de união) e teste de Kruskall-Wallis (espessura do cimento). Comparações múltiplas foram realizadas com o teste Student-Newman-Keuls. Análise de regressão, modelo linear, foi empregada para verificar a correlação entre espessura do cimento e resistência de união. Todos os testes foram aplicados com &#945; = 0,05. O fator cimento exerceu influência significativa para a resistência de união (p = 0,0402): o RelyX U100 apresentou a maior média. A ativação dual elevou os valores de resistência de união em comparação ao modo quimicamente ativado (p < 0,0001). Houve diferenças significantes entre os grupos, sendo G1 (22,4 4,0 MPa) > G3 (20,4 3,6 MPa) > G4 (17,8 5,2 MPa) > G2 (13,5 4,3 MPa). O terço do conduto não exerceu influência significativa sobre a resistência adesiva (p = 0,4749). As espessuras dos filmes de cimento foram estatisticamente diferentes nos diferentes terços: cervical (102 45 m) > médio (75 29 m) > apical (52 28m). Não foi observada forte correlação entre os valores de espessura e os de resistência ao push-out (r = - 0,2016, p = 0,0033). O tipo de falha predominante foi a mista, exceto para o G2, que apresentou 74% das falhas na interface cimento-pino. Dessa forma, o cimento autoadesivo apresentou melhor desempenho que o convencional, e ambos os sistemas duais, sobretudo o RelyX ARC, apresentaram dependência da fotoativação para atingirem maiores valores de resistência de união. / The aim of this study was to evaluate the influence of adhesive cementation system approach (total-etch or self-adhesive), activation mode (self-cure or dual-cure), canal third (cervical, middle or apical) and cement thickness on push-out bond strength of glass fiber post bonded on human roots. Forty roots were embebed in epoxy resin and endodontically treated (filled with guta percha and non-eugenol endodontic sealer). Following 7 days, the post spaces were prepared with low-speed post drills provided by the manufacturer (WhitePost DC #2, FGM) at a depth of 10 mm and the roots were randomly divided in 4 groups, according to cementation system and activations mode: (G1) RelyX ARC/Adper Scotchbond Multi-Purpose Plus (total-etch), dual-cure (G2) RelyX ARC/Adper Scotchbond Multi-Purpose Plus, self-cure, (G3) RelyX U100 (self-adhesive), dual-cure and (G4) RelyX U100, self-cure. After 7 days, each root was sectioned with water-cooled diamond blade, generating six 1-mm thickness slices (n=60). Before push-out bond strength test, digital images of both sides of the slices were captured with digital camera, in order to measure the post radius and the cement thickness. After mechanical test, new images were captured to evaluate the failure mode. A macro was developed in KS 400 software to speed and standardize the evaluation of cement thickness. Results were analyzed using three-way ANOVA (push-out) and Kruskall-Wallis test (cement thickness). Post-hoc multiple comparisons were performed using the Student-Newman-Keuls test. The correlation between resin cement thickness and bond strength was evaluated with regression analysis, linear model. All tests were performed with significance level set at 0.05. Push-out bond strength was significantly influenced by cement type (p= 0.0402): the RelyX U100 cement presented higher mean value. The dual-activated mode increased the bond strength in comparison to self-activated mode (p < 0.0001). Statically differences were observed between groups: G1 (22.4 4.0 MPa) > G3 (20.4 3.6 MPa) > G4 (17.8 5.2 MPa) > G2 (13.5 4.3 MPa). Bond strength was not affected by post space depth (p = 0,4749). The resin cement thicknesses were significantly different in root thirds: cervical (102 45 m) > middle (75 29 m) > apical (52 28m). No strong correlation between cement thickness and push-out bond strength was observed (r = - 0.2016, p = 0.0033). The main failure mode was mixed, except for G2 (74% adhesive failures at post-cement interface). It was concluded tha the self-adhesive cement showed a better performance than the conventional one, and both dual resin systems, specially the RelyX ARC, presented photo-activation dependence to attain greater adhesive bond strength.
310

Efeito da atmosfera de sinterização na resistência de união da porcelana com ligas de níquel-cromo e cobalto-cromo / Effect of firing atmosphere on metal ceramic bond strength of nickel-chromium and cobalt-chromium

Luciana Mara Negrão Alves 11 February 2015 (has links)
O objetivo deste trabalho foi avaliar a influência de dois diferentes ambientes de sinterização (vácuo e argônio) sobre a resistência da união metaloceramica (RUMC) envolvendo diferentes ligas de metais básicos (Co-Cr e Ni-Cr) e uma porcelana odontológica, através do teste de flexão de três pontos, conforme preconizado pela ISO 9693:2012. As ligas estudadas foram Co-Cr: Remanium e Keragen e Ni-Cr: Verabond II e uma liga experimental &ldquo;SR&rdquo; . Foram obtidos 80 corpos de prova em forma tiras metálicas medindo 25 X 0,5 X 5 mm. Para esse ensaio, portanto, o número de corpos de prova foi o produto de 4 ligas x 2 condições de atmosfera de sinterização x 10 repetições. A parte metálica de todos os corpos de prova após a fundição foram usinados e jateados com óxido de alumínio (150&mu;m) e a seguir tratados como preconizado pelo fabricante. O corpo cerâmico, com o auxílio de uma matriz, foi confeccionado na área central da tira, 8,0 X 3,0mm, apresentando 1,1mm de espessura, sendo 10 corpos de prova em cada ambiente de sinterização para cada tipo de liga. Os corpos de prova obtidos foram submetidos aos testes de flexão de três pontos na Máquina de Ensaios Mecânicos (EMIC) com velocidade de 1.0mm/min. para determinação da RUMC. Os valores da carga de ruptura obtidos em quilograma-força (Kgf) foram convertidos para Newton (N) e a partir disso foi calculado o valor da RUMC para cada corpo de prova, considerando o coeficiente de elasticidade de cada liga e a espessura exata de cada corpo de prova. Os dados obtidos (MPa) foram submetidos à análise estatística (ANOVA) e Bonferroni. A Análise de Variância indicou diferença estatisticamente significante para os fatores de variação ambiente (P=0,00), liga (P=0,009) e entre as interações ambiente de sinterização e liga (P=0,000). Na sinterização a vácuo as ligas Keragen, SR e Verabond II apresentaram maiores valores de RUMC do que o argônio. Para a liga Remanium, não houve diferença entre a sinterização em argônio e a sinterização a vácuo. Dentre os grupos sinterizados no argônio não houve diferença estatisticamente significante entre as ligas. Entretanto, no vácuo a liga Remanium apresentou menor valor de RUMC do que as demais ligas, que não apresentaram diferença entre si. Os corpos de prova, após os ensaios de flexão, foram submetidos a análise em microscopia optica, MEV e EDS para avaliar e registrar tipo de falha que sofreram. De acordo com a MO, houve predomínio de fraturas mistas. Os corpos de prova de Co-Cr (Remanium e Keragen), independende do ambiente de sinterização, apresentaram uma fina camada de óxido no corpo cerâmico, o que foi comprovado pelo EDS, com maior presença de íons Cr nessas regiões, já os grupos SR e Verabond II, apresentaram maior quantidade de opaco aderido em suas tiras metálicas. A MEV comprovou os achados da MO, onde foi possível encontrar grandes ilhas de material cerâmico nas ligas de Ni-Cr. A sinterização em argônio influenciou negativamente a RUMC dos pares metalocerâmicos confeccionados em Ni-Cr e na liga Keragem / The aim of this study was to evaluate the influence of two different firing atmosphere (vacuum and argon) on the metalceramic bond strength (MCBS) involving different base metal alloys (Co-Cr and Ni-Cr) and a dental porcelain through three-point bending test, as recommended by ISO 9693: 2012. Co-Cr alloys studied were: Remanium and Keragen and Ni-Cr: Verabond II and an experimental alloy \"SR\". 80 specimens were obtained in metallic form strips measuring 25X0.5 X 5.0 mm. For this test, therefore, the number of specimens was the product of 4 x 2 alloy sintering atmosphere conditions x 10 replicates. The metal portion of all specimens were machined after casting and sandblasted with aluminum oxide (100&mu;m) and then treated as recommended by the manufacturer. By using a matrix, the ceramic body was made in the central area of the strip, 8.0 x 3.0 mm, it was made 1.1 mm thickness, 10 specimens in each sintering environment for each type of alloy. The specimens obtained were tested for three-point bending in a universal testing machine with a speed of 1.0mm / min. to determine MCBS. The values of the tensile strength obtained in kilogramforce (kgf) were converted into Newton (N) and from this the value of MCBS for each specimen was calculated, considering the coefficient of elasticity of each league and the exact thickness of each specimen. The data (MPa) were subjected to statistical analysis (ANOVA) and Bonferroni. The analysis of variance indicated statistically significant difference for the environment factors of firing atmosphere (P = 0.00) and alloy (P = 0.009). There was a statistically significant difference in the interaction factors for firing atmosphere x alloy (P = 0.000). In the vacuum Keragen, SR and Verabond II alloys showed higher MCBS than argon. To Remanium, there was no difference between the sintering in argon and vacuum. Among the groups sintered in argon there was no statistically significant difference between the alloys. However, the vacuum Remanium showed the lowest RUMC than other alloys, which showed no difference between them. The specimens after the bending tests, were subjected to analysis in optical microscopy, SEM and EDS to assess and record type of failure they suffered. According to the MO was predominantly mixed fractures. Specimens of Co-Cr (Remanium and Keragen) independende the atmosphere firing, showed a thin oxide layer on the ceramic body, which was confirmed by EDS, with greater presence of Cr in these regions, since the SR groups and Verabond II, presented more opaque stuck in their metal strips. SEM confirmed the findings of MO, where it was possible to find large islands of ceramic material in Ni-Cr alloys. The sintering in argon negatively influenced MCBS metalceramic of pairs made of Ni-Cr alloy and Keragem

Page generated in 0.0979 seconds