• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 20
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 31
  • 31
  • 18
  • 17
  • 12
  • 10
  • 10
  • 9
  • 8
  • 8
  • 7
  • 7
  • 6
  • 6
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

The effect of using variable curing light types and intensities on the parameters of a mathematical model that predicts the depth of the cure of light-activated dental composites

Ridha, Hashem M., January 2009 (has links)
Thesis (M.S.D.)--Indiana University School of Dentistry, 2009. / Title from PDF t.p. (viewed Feb. 5, 2010) Advisor(s): John A. Levon, Chair of the Research Committee, Carl J. Andres, Tien-Min Gabriel Chu, David Brown, Suteera Hovijitra. Curriculum vitae. Includes abstract. Includes bibliographical references (leaves 66-69).
2

Estudo da contração de polimerização e do grau de conversão em função de diferentes resinas compostas e diferentes aparelhos fotopolimerizadores

Carlo, Hugo Lemes [UNESP] 19 October 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:09Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-10-19Bitstream added on 2014-06-13T18:51:43Z : No. of bitstreams: 1 carlo_hl_me_arafo.pdf: 663650 bytes, checksum: 1703d1cf829a007bfb4eb9e624207ea1 (MD5) / O objetivo deste trabalho foi avaliar a contração de polimerização linear e o grau de conversão de duas marcas comerciais de resinas compostas, com composições semelhantes, sendo uma de uso em dentes anteriores e posteriores (Filtek Z250) e outra para uso em dentes posteriores (Filtek P60). Também foi avaliado o efeito de diferentes fontes de luz nesse processo, utilizando-se para isso aparelho de luz halógena (Degulux - Degussa) e aparelho LED de alta intensidade (Ultrablue IS - DMC). Dessa forma, os materiais e fontes de luz foram divididos em quatro grupos: Grupo 1 - resina Filtek Z250 polimerizada com o aparelho de luz halógena (LH); Grupo 2 - resina Filtek Z250 polimerizada com aparelho LED (LED); Grupo 3 - resina Filtek P60 polimerizada com o aparelho de luz halógena (LH); Grupo 4 - resina Filtek P60 polimerizada com o aparelho LED (LED). A contração de polimerização foi medida com a inserção dos materiais em um anel plástico e a mensuração das alterações realizada por um instrumento eletrônico de medida linear com sensibilidade para 1 æm. O grau de conversão foi obtido através de teste de espectrometria no infravermelho por transformações de Fourier (FTIR), onde foram analisados os picos dentro das bandas de interesse nos valores de 1.646 cm-1 e 1.731 cm-1, correspondentes às ligações C=C alifática e C=O respectivamente. Os resultados foram submetidos à análise estatística de Variância e teste de Tukey (a = 0,05), os quais permitiram concluir que: a contração de polimerização de diferentes materiais (Filtek Z250 e Filtek P60) apresentou comportamento diferente mediante a mesma fonte luz (LED); o grau de conversão dos materiais apresentou-se estatisticamente semelhante em relação aos materiais e aparelhos fotopolimerizadores; o aparelho LED (Ultrablue IS) apresentou resultados de...
3

Estudo da contração de polimerização e do grau de conversão em função de diferentes resinas compostas e diferentes aparelhos fotopolimerizadores /

Carlo, Hugo Lemes. January 2004 (has links)
Orientador: Maria Salete Machado Cândido / Banca: José Roberto Cury Saad / Banca: Jesuania Maria Guardiero Azevedo Pfeifer / Abstract: The aim of this work was to evaluate the linear polymerization shrinkage and the degree of conversion of two commercial composite resins, with similar compositions, being one of use in anterior and posterior teeth (Filtek Z250) and other for use in posterior teeth (Filtek P60). The effect of different light sources was also evaluated in that process, and were used for that an halogen light curing (Degulux - Degussa) and a LED light curing of high intensity (Ultrablue IS - DMC). In that way, the materials and light sources were divided in four groups: Group 1 - Filtek Z250 resin cured with the halogen light curing (QHT); Group 2 - Filtek Z250 cured with LED light curing (LED); Group 3 - Filtek P60 resin cured with the halogen light curing (QHT); Group 4 - Filtek P60 cured with the LED light curing (LED). The polymerization shrinkage was measured with the insert of the materials in a plastic tube and the values of the alterations accomplished by an electronic instrument of linear measure with sensibility for 1æm. The conversion degree was obtained through Fourier Transform Infrared Spectroscopy (FTIR), where the picks were analyzed inside of the bands of interest in the values of 1.646 cm-1 and 1.731 cm-1, corresponding to the connections C=C aliphatic and C=O respectively. The results were submitted to the statistical analysis of Variance and test of Tukey (a = 0,05), which allowed to end that: the polymerization shrinkage of different materials (Filtek Z250 and Filtek P60) presented different behavior with the use of the same light source (LED); the degree of conversion of the materials came similar in relation to materials and light sources; the LED light curing (Ultrablue IS) presented results of polymerization shrinkage and degree of conversion that allow it to be used as an alternative to QHT light curing units. / Resumo: O objetivo deste trabalho foi avaliar a contração de polimerização linear e o grau de conversão de duas marcas comerciais de resinas compostas, com composições semelhantes, sendo uma de uso em dentes anteriores e posteriores (Filtek Z250) e outra para uso em dentes posteriores (Filtek P60). Também foi avaliado o efeito de diferentes fontes de luz nesse processo, utilizando-se para isso aparelho de luz halógena (Degulux - Degussa) e aparelho LED de alta intensidade (Ultrablue IS - DMC). Dessa forma, os materiais e fontes de luz foram divididos em quatro grupos: Grupo 1 - resina Filtek Z250 polimerizada com o aparelho de luz halógena (LH); Grupo 2 - resina Filtek Z250 polimerizada com aparelho LED (LED); Grupo 3 - resina Filtek P60 polimerizada com o aparelho de luz halógena (LH); Grupo 4 - resina Filtek P60 polimerizada com o aparelho LED (LED). A contração de polimerização foi medida com a inserção dos materiais em um anel plástico e a mensuração das alterações realizada por um instrumento eletrônico de medida linear com sensibilidade para 1 æm. O grau de conversão foi obtido através de teste de espectrometria no infravermelho por transformações de Fourier (FTIR), onde foram analisados os picos dentro das bandas de interesse nos valores de 1.646 cm-1 e 1.731 cm-1, correspondentes às ligações C=C alifática e C=O respectivamente. Os resultados foram submetidos à análise estatística de Variância e teste de Tukey (a = 0,05), os quais permitiram concluir que: a contração de polimerização de diferentes materiais (Filtek Z250 e Filtek P60) apresentou comportamento diferente mediante a mesma fonte luz (LED); o grau de conversão dos materiais apresentou-se estatisticamente semelhante em relação aos materiais e aparelhos fotopolimerizadores; o aparelho LED (Ultrablue IS) apresentou resultados de... (Resumo completo, clicar acesso eletrônico abaixo) / Mestre
4

Influência da distância de uma fonte de luz halógena na microdureza superficial da resina composta

Alencar Júnior, Emmanuel Arraes de [UNESP] 19 February 2002 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2002-02-19Bitstream added on 2014-06-13T20:12:03Z : No. of bitstreams: 1 alencarjunior_ea_me_arafo_prot.pdf: 747787 bytes, checksum: fd32e276778e87934566a313af1035b5 (MD5) / O objetivo desta pesquisa foi avaliar a influência da distância de uma fonte de luz halógena na microdureza superficial da resina composta, considerando as superfícies de topo e base dos corpos-de-prova. Foram utilizadas duas marcas comerciais de resina composta, Z250 de partículas pequenas e uma resina de micropartícula, A110, ambas da 3M do Brasil Ltda. O aparelho de ativação da resina composta foi K&M 220- R, cuja intensidade de luz possui um pulso que variava após os 5 primeiros segundos assim alcançando sua intensidade máxima que foi medida em 720 mW/cm2. Para a determinação da intensidade de luz emitida pelo aparelho fotoativador, utilizou-se um radiômetro (Medidor de irradiância 150- CMC , São Carlos - SP). Corpos-de-prova foram confeccionados utilizado-se matrizes metálicas que possuíam um orifício central de 4mm de diâmetro por 2mm de espessura. As resinas foram inseridas no orifício da matriz metálica, em um único incremento, por meio de uma espátula metálica e sobre elas foi sobreposta uma tira matriz transparente de poliéster e, após isto, um peso de 1 Kg foi posto em cima da tira para que houvesse uma melhor condensação da resina composta evitando a presença de bolhas de ar, no interior do corpo-de-prova. A fonte de luz halógena foi fixada em uma mesa de maneira que a saída da ponta de luz ficasse paralela à superfície do corpo-de-prova. Para provocar o distanciamento da fonte de luz, anéis metálicos confeccionados em latão, com espessuras que variavam de 2mm, 4mm e 8mm foram utilizados, os quais, após posicionados, eram removidos para não interferiem no dispersamento da luz. As distâncias imprimidas a fonte de luz na superfície da resina foram de 0mm(tocando a superfície), 2mm, 4mm e 8mm. Para cada uma destas distâncias, a intensidade de luz foi medida. Esta variou de intensidade de... . / The aim of this research was to evaluate the influence of the light tip distance in the superficial microhardness of the composite resin, considering the surfaces of top and base of the samples. Two commercial composite resin marks had been used, Z250 of small particles e a microparticle resin, A110, both of 3m of Brazil Ltda. The device of activation of the composite resin was K&M 220- R, whose intensity of light possess a pulse that varied the 5 first seconds after thus reaching its maximum intensity that was measured in 720 mW/cm2. For the determination of the intensity of light emitted for the fotoativador device, a radiometer (Measuring of irradiance 150- CMC was used, Is Carlos. SP). The samples had been confectioned used first metallic that had a central orifice of 4mm of diameter for 2mm of thickness. The resins had been inserted in the orifice of the metallic array, in an only increment, by means of a metallic spatula and on them a transparent first polyester strap was overlapped and, after this, one weight of 1 kg was rank in top of the strap so that it had one better condensation of the composite resin preventing the presence of air bubbles, in the inward of the body-of-test. The source of light was fixed in a table thus the output of the light tip was parallel to the surface of the body-of-test. To provoke distance from the light source, confectioned metallic rings in brass, with thickness that varied of 2mm, 4mm and 8mm had been used, which, after located, was removed to avoid concentration of light. The printed pitches the source of light in the surface of the resin had been of 0mm(on the surface), 2mm, 4mm and 8mm. For each one of these pitches, the light intensity was measured. This varied of intensity of 720 mW/cm2 for the tip touching the surface of the body-of-test, 650 mW/cm2 for in the distance of 2mm, 600 mW/cm2... (Complete abstract, click electronic address below).
5

Avaliação por microdureza Vickers da profundidade de polimerização de cimentos resinosos na cimentação de pinos de fibra de vidro empregando diferentes fontes de luz

Conti, Elaine Cristina Guerbach [UNESP] January 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2006Bitstream added on 2014-06-13T20:41:44Z : No. of bitstreams: 1 conti_ecg_dr_arafo.pdf: 812838 bytes, checksum: c0f89cff921f9b0a2343ffde10308ae3 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo desse estudo foi avaliar a microdureza Vickers de um cimento resinoso químico (C&B Cement - Bisco) e um de ativação dual (RelyX ARC - 3M ESPE), fotopolimerizado por diferentes fontes de luz, em função de diferentes profundidades do canal radicular, na cimentação de pinos de fibra de vidro. Os aparelhos fotopolimerizadores empregados foram: Optilux 360 (Demetron) - luz halógena; Radii (SDI) - LED; UltraLume 5 (Ultradent) - LED. Nenhuma diferença estatisticamente significante foi observada nos valores de microdureza Vickers, dos terços cervical, médio e apical do canal radicular, para o cimento resinoso químico (G1), e os terços cervicais do cimento resinoso dual, para todos os aparelhos fotopolimerizadores (G2, G3 e G4) (p>0.05). Porém, o aparelho de luz halógena (G2) e o LED UltraLume 5 (G4) apresentaram comportamentos semelhantes, proporcionando uma diminuição gradativa nos valores médios de microdureza do cimento resinoso dual, do terço cervical para o apical (p<0.001). Os menores valores de microdureza foram encontrados nos terços apical do sistema RelyX ARC fotopolimerizado com luz halógena ou com LED UltraLume 5. / This study evaluated the Vickers microhardness of a chemically cured resin cement (C&B Cement - Bisco) and a dual cure cement (RelyX ARC - 3M ESPE), light cured by different light sources, according to the different root canal depths, for luting of glass fiber posts. The light curing units employed were Optilux 360 (Demetron) - halogen lamp; Radii (SDI) - LED; UltraLume 5 (Ultradent) - LED. No statistically significant difference was observed in Vickers microhardness values at the cervical, middle and apical root thirds for the chemically cured resin cement (G1), and at the cervical third for the dual resin cement, for all light curing units (G2, G3 and G4) (p>0.05). However, the halogen lamp unit (G2) and LED UltraLume 5 (G4) presented similar performance, providing gradual reduction in mean microhardness values for the dual resin cement from the cervical to the apical third (p<0.001). The lowest microhardness values were found at the apical third for the system RelyX ARC light cured with halogen lamp or LED UltraLume 5.
6

Influência da distância de uma fonte de luz halógena na microdureza superficial da resina composta /

Alencar Júnior, Emmanuel Arraes de. January 2002 (has links)
Orientador: Marcelo Ferrarezi de Andrade / Banca: José Roberto Cury Saad / Banca: Mânio de Carvalho Tibúrcio / Resumo: O objetivo desta pesquisa foi avaliar a influência da distância de uma fonte de luz halógena na microdureza superficial da resina composta, considerando as superfícies de topo e base dos corpos-de-prova. Foram utilizadas duas marcas comerciais de resina composta, Z250 de partículas pequenas e uma resina de micropartícula, A110, ambas da 3M do Brasil Ltda. O aparelho de ativação da resina composta foi K&M 220- R, cuja intensidade de luz possui um pulso que variava após os 5 primeiros segundos assim alcançando sua intensidade máxima que foi medida em 720 mW/cm2. Para a determinação da intensidade de luz emitida pelo aparelho fotoativador, utilizou-se um radiômetro (Medidor de irradiância 150- CMC , São Carlos - SP). Corpos-de-prova foram confeccionados utilizado-se matrizes metálicas que possuíam um orifício central de 4mm de diâmetro por 2mm de espessura. As resinas foram inseridas no orifício da matriz metálica, em um único incremento, por meio de uma espátula metálica e sobre elas foi sobreposta uma tira matriz transparente de poliéster e, após isto, um peso de 1 Kg foi posto em cima da tira para que houvesse uma melhor condensação da resina composta evitando a presença de bolhas de ar, no interior do corpo-de-prova. A fonte de luz halógena foi fixada em uma mesa de maneira que a saída da ponta de luz ficasse paralela à superfície do corpo-de-prova. Para provocar o distanciamento da fonte de luz, anéis metálicos confeccionados em latão, com espessuras que variavam de 2mm, 4mm e 8mm foram utilizados, os quais, após posicionados, eram removidos para não interferiem no dispersamento da luz. As distâncias imprimidas a fonte de luz na superfície da resina foram de 0mm(tocando a superfície), 2mm, 4mm e 8mm. Para cada uma destas distâncias, a intensidade de luz foi medida. Esta variou de intensidade de... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The aim of this research was to evaluate the influence of the light tip distance in the superficial microhardness of the composite resin, considering the surfaces of top and base of the samples. Two commercial composite resin marks had been used, Z250 of small particles e a microparticle resin, A110, both of 3m of Brazil Ltda. The device of activation of the composite resin was K&M 220- R, whose intensity of light possess a pulse that varied the 5 first seconds after thus reaching its maximum intensity that was measured in 720 mW/cm2. For the determination of the intensity of light emitted for the fotoativador device, a radiometer (Measuring of irradiance 150- CMC was used, Is Carlos. SP). The samples had been confectioned used first metallic that had a central orifice of 4mm of diameter for 2mm of thickness. The resins had been inserted in the orifice of the metallic array, in an only increment, by means of a metallic spatula and on them a transparent first polyester strap was overlapped and, after this, one weight of 1 kg was rank in top of the strap so that it had one better condensation of the composite resin preventing the presence of air bubbles, in the inward of the body-of-test. The source of light was fixed in a table thus the output of the light tip was parallel to the surface of the body-of-test. To provoke distance from the light source, confectioned metallic rings in brass, with thickness that varied of 2mm, 4mm and 8mm had been used, which, after located, was removed to avoid concentration of light. The printed pitches the source of light in the surface of the resin had been of 0mm(on the surface), 2mm, 4mm and 8mm. For each one of these pitches, the light intensity was measured. This varied of intensity of 720 mW/cm2 for the tip touching the surface of the body-of-test, 650 mW/cm2 for in the distance of 2mm, 600 mW/cm2... (Complete abstract, click electronic address below). / Mestre
7

Influência de fotoiniciadores alternativos na durabilidade da união, adaptação marginal e propriedades físico-químicas de resinas adesivas experimentais fotoativadas por LEDs / Influence of alternative photoinitiators on bond durability, marginal adaptation and physical-chemical properties of experimental adhesive resins photocured by LEDs

Souza Júnior, Eduardo José Carvalho de, 1985- 25 August 2018 (has links)
Orientador: Mario Alexandre Coelho Sinhoreti / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-25T16:27:57Z (GMT). No. of bitstreams: 1 SouzaJunior_EduardoJoseCarvalhode_D.pdf: 1265761 bytes, checksum: 1e110af2f222e502411203feb253160f (MD5) Previous issue date: 2014 / Resumo: O objetivo neste estudo foi analisar o efeito de diodos emissores de luz (LEDs) nas propriedades físicas, químicas, resistência da união (RU), adaptação marginal (AM) e na durabilidade de restaurações realizadas com adesivos experimentais contendo diferentes fotoiniciadores. Uma resina modelo contendo uma mistura de BisGMA/HEMA (60/40 em peso) e dimetil amino etil metacrilato (co-iniciador) foi preparada com os diferentes fotoiniciadores: CQ (Canforoquinona), PPD (1-Fenil-1,2-Propanodiona) e BAPO (Óxido bis-alquil fosfínico), além da associação entre eles. As amostras foram fotoativadas por duas fontes de luz LED, uma de 2° geração (Radii Cal, SDI) e outra de 3° geração (Bluephase G2, Ivoclar Vivadent). A irradiância foi aferida a partir de medidas em potênciômetro e a densidade energética foi padronizada em 48J/cm2. As propriedades avaliadas foram o grau de conversão (GC), cinética de polimerização (CI), análise da permeabilidade dentinária (PMD), sorção (SO) e solubilidade (SL), resistência flexural (RF), módulo flexural (MF) e amarelamento (YL). Para o teste de RU, o ensaio de microtração foi realizado em dentina plana de 70 molares humanos, avaliados após 24 horas e após 1 ano de armazenamento em água a 37ºC. A AM foi mensurada por meio de réplicas das margens superficial e interna de 70 molares humanos, analisadas em microscopia eletrônica de varredura (MEV). Os ensaios de GC, PMD, SO, SL, RF, MF e AM foram submetidos à análise de variância dois fatores, enquanto a RU foi submetida à análise de variância dois fatores (fotoiniciadores e fontes de luz), com medidas repetidas no tempo. Após, todas as médias foram comparadas pelo teste de Tukey ('alfa' = 5%). Os adesivos contendo os fotoiniciadores alternativos, em especial BAPO e BAPO/amina monstraram maior potencial de polimerização, evidenciado pela cinética de conversão. Ainda, os fotoiniciadores alternativos promoveram melhor selamento dentinário, sorção e solubilidade similares e propriedades físico-químicas com melhor desempenho quando comparados aos adesivos convencionais contendo CQ. Em relação à resistência de união, os adesivos contendo BAPO promoveram os melhores desempenhos em até um ano de degradação hidrolítica / Abstract: The aim of this study was to evaluate the effect of light emitting diodes (LEDs) on the physical-chemical properties, bond strength (BS) and marginal adaptation (MA) of experimental adhesives containing diferent photo-initiators. A model resin containing a mixture of BisGMA/HEMA (60/40 wt%) and DMAEMA (co-iniciator) was prepared using different photo-initiators: CQ (Camphorquinone), PPD (1-Phenyl-1,2-Propanedione) e BAPO (Bisalquylphosphine oxide) and their association. The specimens were photoactivated by two LEDs, one monowave (Radii Cal, SDI) and other polywave (Bluephase G2, Ivoclar Vivadent). Irradiance was measured in potenciometer and the energy dose was standardized. The following properties were analyzed: degree of conversion (DC) and for the curing kinetics (CI), dentin permeability (DPM), water sorption (SO), water solubility (SL), flexural strength (FS), flexural modulus (FM) and yellowing (YL). For the BS test, the microtensile test was realized in 70 molars with planned dentin, immediately or after 1-year of water storage. The MA, superficial and internal marginal adaptation measurements were realized by epoxy replicas of the bonded margins using the scanning eléctron microscopy. DC, DPM, SO, SL, FS, FM and AM were submitted to a two-way ANOVA and BS to a two-way repeated measurement ANOVA. Next, the analyzes were submitted to the Tukey¿s test ('alfa' = 5%). The adhesives containing the alternative photoinitiators, such as BAPO and BAPO/amine showed a higher curing potential, promoted by the curing kinetics. Moreover, these alternative photoinitiators showed a better dentin sealing, with similar sorption and solubility values and high physical-mechanical properties when compared to the other groups based in CQ. In relation to the bond strength, the BAPO containing adhesives promoted higher performance even after 1-year of hydrolytic degradation / Doutorado / Materiais Dentarios / Doutor em Materiais Dentários
8

Influência de diferentes fontes fotoativadoras na resistência adesiva de restauração indireta de resina composta

Camilotti, Veridiana 15 December 2005 (has links)
Made available in DSpace on 2017-07-24T19:22:22Z (GMT). No. of bitstreams: 1 VeridianaCamilotti.pdf: 624713 bytes, checksum: f2d0756374875dd344e9aeeecdaac9cc (MD5) Previous issue date: 2005-12-15 / The following study aims to evaluate the influence between the different light sources in curing light of resin cement. The occlusal surfaces of twenty recently extractew undamaged third human molars were removed in order to expose dentine surface. Immediately after, the bond system (Adper Single Bond/3M ESPE ) and resin cement (RelyX ARC/ 3 M ESPE) was applied in accordance with manufacturer instructions. Second generation laboratory resin of 4 mm thickness was applied over tooth and light curing proceeded. According to light sources employed the teeth were divided in four groups: G1 – Control Optilux 401/ Demetron (QTH); G2 – L.E.Demetron/Demetron (LEDs ); G3 – Ultra-Lume LED5 (LEDs) e G4 – Optilight CL/ Gnatus (LEDs). Restored teeth were stored in physiologic serum for 24 h. After stored, teeth were sectioned into vestibule-tongue and mesial-distal to delimit an area with approximately 1 mm², the third cut was made on the base of the tooth in order to release the samples. The microtensile test was employed to reveal the bond strength values in MPa. The data underwent statistical analysis with p<0,05. No statistical significancent difference was found betweem the groups. In conclusion the resin cement bon strength of dual fotoative with LEDs showed similar adhesive resistance test those revelead when halogen lamp was used, and that there also were not differences among the different apparels LEDs used in that study. / Avaliou-se a influência de diferentes fontes de luz na fotoativação de um cimento resinoso dual. A superfície oclusal de 20 terceiros molares humanos hígidos foi removida para expor a superfície dentinária. Em seguida, foi aplicado sistema adesivo (Adper Single Bond/3M ESPE ) e cimento resinoso dual (RelyX ARC/ 3 M ESPE), de acordo com as recomendações do fabricante. A resina laboratorial de segunda geração (Gradia™ GC® América Inc), com espessura de 4 mm, foi adaptada sobre o dente e procedeu-se à fotoativação. De acordo com o aparelho de luz empregado, os elementos dentais foram divididos em 4 grupos: G1 – controle Optilux 401/ Demetron (QTH); G2 – L.E.Demetron 1/Demetron (LEDs ); G3 – Ultra- Lume LED5/Ultradent (LEDs) e G4 – Optilight CL/ Gnatus (LEDs). Os dentes restaurados foram armazenados em soro fisiológico por 24 h. Após o armazenamento, os dentes foram seccionados no sentido vestíbulo-lingual e mésiodistal, para delimitar uma área de 1 mm². Um terceiro corte na base do dente foi realizado com o objetivo de “soltar” os espécimes. O teste de micro-tração foi empregado para fornecer os valores da resistência adesiva em MPa. Os dados foram submetidos à análise estatística pelo teste ANOVA com p<0,05. Não houve diferenças estatisticamente significante entre os grupos testados. Concluiu-se que a resistência adesiva da interace adesiva fotoativado com LEDs foi semelhante à resistência adesiva obtida quando a lâmpada halógena foi utilizada e que também não houve diferenças entre os diferentes aparelhos LEDs empregados nesse estudo.
9

Avaliação por microdureza Vickers da profundidade de polimerização de cimentos resinosos na cimentação de pinos de fibra de vidro empregando diferentes fontes de luz /

Conti, Elaine Cristina Guerbach. January 2006 (has links)
Orientador: José Roberto Cury Saad / Banca: Patrícia dos Santos Jardim / Banca: Luiz Alberto Plácido Penna / Banca: Osmir Batista de Oliveira Júnior / Banca: Marcelo Ferrarezi de Andrade / Resumo: O objetivo desse estudo foi avaliar a microdureza Vickers de um cimento resinoso químico (C&B Cement - Bisco) e um de ativação dual (RelyX ARC - 3M ESPE), fotopolimerizado por diferentes fontes de luz, em função de diferentes profundidades do canal radicular, na cimentação de pinos de fibra de vidro. Os aparelhos fotopolimerizadores empregados foram: Optilux 360 (Demetron) - luz halógena; Radii (SDI) - LED; UltraLume 5 (Ultradent) - LED. Nenhuma diferença estatisticamente significante foi observada nos valores de microdureza Vickers, dos terços cervical, médio e apical do canal radicular, para o cimento resinoso químico (G1), e os terços cervicais do cimento resinoso dual, para todos os aparelhos fotopolimerizadores (G2, G3 e G4) (p>0.05). Porém, o aparelho de luz halógena (G2) e o LED UltraLume 5 (G4) apresentaram comportamentos semelhantes, proporcionando uma diminuição gradativa nos valores médios de microdureza do cimento resinoso dual, do terço cervical para o apical (p<0.001). Os menores valores de microdureza foram encontrados nos terços apical do sistema RelyX ARC fotopolimerizado com luz halógena ou com LED UltraLume 5. / Abstract: This study evaluated the Vickers microhardness of a chemically cured resin cement (C&B Cement - Bisco) and a dual cure cement (RelyX ARC - 3M ESPE), light cured by different light sources, according to the different root canal depths, for luting of glass fiber posts. The light curing units employed were Optilux 360 (Demetron) - halogen lamp; Radii (SDI) - LED; UltraLume 5 (Ultradent) - LED. No statistically significant difference was observed in Vickers microhardness values at the cervical, middle and apical root thirds for the chemically cured resin cement (G1), and at the cervical third for the dual resin cement, for all light curing units (G2, G3 and G4) (p>0.05). However, the halogen lamp unit (G2) and LED UltraLume 5 (G4) presented similar performance, providing gradual reduction in mean microhardness values for the dual resin cement from the cervical to the apical third (p<0.001). The lowest microhardness values were found at the apical third for the system RelyX ARC light cured with halogen lamp or LED UltraLume 5. / Doutor
10

Efeito de fontes de luz LED e condicionamento ácido do esmalte na resistência à microtração, dureza Knoop e formação de fendas de restaurações classe I em compósito utilizando adesivos autocondicionantes / Effect of the LED curing source and enamel acid etching on the microtensile bond strenght, Knoop hardness and gap formation of class I composite restorations using seflf-etch adhesives

Souza Júnior, Eduardo José Carvalho de, 1985- 17 August 2018 (has links)
Orientador: Luís Alexandre Maffei Sartini Paulillo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-17T23:46:46Z (GMT). No. of bitstreams: 1 SouzaJunior_EduardoJoseCarvalhode_M.pdf: 3521538 bytes, checksum: c8b050fbf4fb259c0dc4d1925121d22a (MD5) Previous issue date: 2011 / Resumo: Os objetivos deste estudo foram: a) avaliar o efeito do condicionamento seletivo do esmalte cavosurperficial e da fonte de luz LED na resistência à microtração em dentina de restaurações Classe I em compósito utilizando adesivos autocondicionantes; b) avaliar a dureza Knoop (KHN) de restaurações de cavidades Classe I em compósito utilizando adesivos autocondicionantes fotoativados com diferentes fontes de luz LED; c) Avaliar a formação de fendas antes e após ciclagem termomecânica de restaurações em compósito fotoativadas por LED e utilizando adesivos autocondicionantes em diferentes protocolos de aplicação. No experimento 1, noventa e seis cavidades Classe I foram preparadas em molares humanos, e restauradas com compósito micro-híbrido. Os espécimes foram distribuídos em 12 grupos (n=8), de acordo com a fonte de luz LED (Radii-Cal - RD, Flash Lite 1401 - FL e Ultra-Lume 5 - UL), sistema adesivo autocondicionante (Clearfil SE Bond - CSE e Clearfil S3 Bond - S3) e condicionamento seletivo do esmalte com ácido fosfórico (com e sem). Após o acabamento e polimento das restaurações as mesmas foram submetidas à fadiga termo-mecânica e os palitos para o ensaio de microtração foram obtidos da interface de união entre a parede pulpar dentinária e a restauração. Após o teste mecânico os dados foram submetidos à análise estatística (ANOVA três fatores e teste de Tukey com ?=0.05). O condicionamento seletivo do esmalte para o S3 diminuiu a resistência de união em dentina e não afetou o desempenho do CSE. Além disso, o LED de terceira geração promoveu maiores valores de resistência à microtração para o adesivo de dois passos. Para o S3 as fontes de luz promoveram resistência adesiva semelhante em dentina. No estudo 2, utilizou-se o mesmo método de preparo das amostras do primeiro estudo, formando-se 6 grupos (n=16) pela interação entre os fatores em estudo, LED (RD, FL e UL), sistema adesivo autocondicionante (CSE e S3). As parcelas subdivididas foram diferentes profundidades (superficial, média e profunda). Após a confecção das restaurações, as mesmas também foram submetidas à fadiga termo-mecânica e em seguida, seccionadas no sentido longitudinal para avaliação da KHN nas diferentes profundidades. Após análise estatística (ANOVA dois fatores com parcela subdividida e teste de Tukey com ?=0.05), observou-se que o LED de terceira geração promoveu valores de KHN semelhante aos aparelhos de pico único e que a região superficial, em geral, apresentou melhor qualidade de polimerização. No estudo 3, utilizou-se 192 terceiros molares, onde cavidades Classe I foram preparadas e restauradas com o mesmo método utilizado no primeiro estudo, 12 grupos (n=16) pela interação entre os fatores em estudo, LED (RD, FL e UL), sistema adesivo autocondicionante (CSE e S3) e condicionamento seletivo do esmalte com ácido fosfórico (com e sem), antes e após a termociclagem. Após a restauração, réplicas em resina epóxica foram confeccionadas e as margens foram analisadas em microscópio eletrônico de Varredura (MEV). Após submeter os espécimes da restauração à fadiga termo-mecânica, novamente réplicas em resina epóxica foram feitas e analisadas em MEV. Após análise estatística (Kruskal Wallis e teste de Wilcoxon pareado, ?=0.05), observou-se que o condicionamento seletivo do esmalte promoveu maior integridade marginal para o S3, mostrando ser um passo adicional eficiente na técnica de aplicação desse adesivo em restaurações Classe I em compósito. Além disso, a formação de fendas para adesivo autocondicionante de dois passos não foi influenciado pelo condicionamento ácido prévio do esmalte, nem pelo LED utilizado para fotoativação / Abstract: The aim of this work was to: a) evaluate the effect of enamel selective enamel etching and LED curing units on dentin microtensile bond strength of Class I composite restorations; b) evaluate the effect of different LED light units and self-etch adhesives on the Knoop hardness profile (KHN) of Class I composite restorations; c) evaluate the gap formation before and after thermomechanical loading of Class I composite restorations photocured by LED and using different application protocols of self-etch adhesives systems. In experiment 1, ninety-six Class I cavities were made in human molars and restored with a microhybrid composite. For the restorative procedure, teeth were assigned in 12 groups (n=8) formed by the studied factors interactions, LED curing unit (Radii-Cal - RD, Flash Lite 1401 -FL and Ultra-Lume 5 - UL), self-etch adhesives (Clearfil SE Bond - CSE and Clearfil S3 Bond - S3) and selective enamel acid etching (with and without). After finishing and polishing approach, specimens were submitted to thermo-mechanical ageing and sticks were obtained from the bonding interface between adhesive and pulpal wall which were submitted to a microtensile load in a universal testing machine. After statistical analysis, (three-way ANOVA and Tukey test with ?=0.05) it was shown that the pre-etched enamel approach for Clearfil S3 decreased dentin bond strength while it did not affect the bond performance of Clearfil SE. Thus, the polywave LED promoted higher microtensile bond strength values for the two-step adhesive. When Clearfil S3 was used, the light curing units yielded similar dentin bond strength. In the experiment 2, 96 Class I cavities were prepared in the same way as the previous experiment. Teeth were assigned to 18 groups (n=8) by the interaction among the studied factors, LED curing source (RD, FL and UL), self-etch bond system (CSE and S3), depth (superficial, medium and deep). After the restorative procedure, specimens were submitted to thermo-mechanical ageing and then sectioned in the longitudinal direction for the Knoop hardness measurement in the different depths. Data were submitted to three-way ANOVA and Tukey test with a pre-set alpha of 0.05). The results showed that the third generation LED promoted similar KHN values to the single-peak ones and the superficial surface, in general, presented greater cure quality compared to the others surface depths. In the experiment 3, 192 third molars were used and Class I preparations were restored in the same way as the first study. Specimens were assigned to 12 groups (n=16) formed by the studied factors interaction, LED (RD, FL and UL), self-etch adhesives (CSE and S3), selective enamel acid etching (with and without) and before and after thermomechanical loading. After the restoration procedure, epoxy resin replicas were made and the marginal adaptation was analyzed in a scanning electron microscope (SEM). Then specimes were submitted to thermalmechanical loading and again, epoxy resin replicas were made and analyzed by SEM. After statistical analysis (Kruskal Wallis and Wilcoxon matched-pairs signed-ranks test, with a pre-set alpha of 0.05), it was shown that selective enamel etching yielded higher marginal integrity for S3, showing to be an efficient additional step for the bonding technique of this adhesive in Class I composite restorations. Also, the two-step self-etch adhesive gap formation was not influenced by the selective enamel etching, neither by the LED curing light / Mestrado / Dentística / Mestre em Clínica Odontológica

Page generated in 0.065 seconds