• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 1
  • Tagged with
  • 10
  • 10
  • 10
  • 10
  • 7
  • 6
  • 5
  • 5
  • 5
  • 5
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Efeito de adesivos modificados por nanopartículas de TiO2 decoradas ou não com prata em diferentes propriedades /

Souza, Victor Trassi Fernandes Silva de. January 2017 (has links)
Orientador: Alessandra Nara de Souza Rastelli / Resumo: O presente estudo teve como objetivo a avaliação do efeito antibacteriano de sistemas adesivos modificados com nanopartículas (NPs) de dióxido de titânio (TiO2) decoradas ou não por prata (Ag) em diferentes concentrações, assim como o grau de conversão e a resistência de união à dentina sendo avaliada imediatamente e após três meses em saliva artificial. Os sistemas adesivos AdperTM Scotch Bond Multi Purpose e AdperTM Single Bond (3M Espe), e Clearfil SE Bond (Kuraray) foram modificados com concentrações 0 (controle); 1; 2 e 5% de NPs de TiO2 (com e sem Ag). Foram confeccionados espécimes cilíndricos em resina composta (FiltekTM Z250XT, 3M Espe) na cor A2 com matrizes metálicas (4x2mm), nos quais foram aplicados os sistemas adesivos modificados ou não, de acordo com as instruções dos fabricantes, para o teste de atividade antibacteriana por contato direto. Os espécimes foram colocados em placa de 24 poços e incubados por 18 horas a 37ºC em atmosfera de microaerofilia juntamente com 100μL de suspensão bacteriana padronizada contendo Streptococcus mutans e 900μL de BHI caldo + sacarose (1%). Para a contagem de unidades formadoras de colônias (UFC/mL), foram realizadas diluições seriadas com as soluções resultantes e 50μL dessas diluições foram plaqueadas em placas de petri contendo BHI ágar, sendo incubadas a 37ºC em 10% de CO2 por 48 horas. O grau de conversão foi avaliado por espectroscopia infravermelho por transformada de Fourier (FT-IR) para todos os adesivos modific... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The present study evaluated the antibacterial effect, the degree of conversion and the micro-shear bond strength (immediate and after three months of water storage) of modified dental adhesive systems with TiO2 or Ag/TiO2 nanoparticles at different concentrations. The adhesive systems AdperTM Single Bond (SB), AdperTMScotchTM Bond Multi Purpose (3M Espe) (SBM) and Clearfil SE Bond (Kuraray) (CB) were modified with 1.0, 2.0 and 5.0 wt% of NPs. For the direct-contact test, sterilized specimens (n=36) were made using a metallic matrix (4x2mm) with the composite resin FiltekTMZ250 XT (3M Espe), on which the dental adhesive systems were applied according to the manufacturer's instructions. Both materials were photo-activated using a LED light-curing unit (LED Radii Plus, SDI). The specimens were placed in a 24-well plate with 100μL of Streptoccocus mutans standardized suspension on their surfaces, 900μL of BHI broth and incubated for 18 hours at 37ºC under an atmosphere containing 5% CO2. A six-fold serial dilution was performed with the resultant solutions. Fifty microliters (50μL) from each dilution was retrieved and spread on brain-heart infusion agar plates and incubated at 37°C under an atmosphere containing 5% of CO2 for 48h and the colony forming units (CFU's) were registered. For the evaluation of the DC, the specimens were made by the modification of the dental adhesive systems with all concentrations of nanoparticles and stored for 24hs at 37ºC in an incubator. The FTIR analysis was conducted using an attenuated total reflectance unit (ATR) at a 4cm-1 resolution and 64 scans. For the micro-shear bond strength test, One hundred and twenty six standardized dentin specimens were made from bovine incisors and divided into twenty-one groups. The control and modified adhesive systems were applied on the surfaces ...(Complete abstract electronic access below) / Mestre
2

Efeito do pré-aquecimento e da pré-refrigeração na dureza e contração de um compósito fotoativado com luz halógena e LED / Fernando Henrique Ruppel Osternack ; orientador, Rui Fernando Mazur

Osternack, Fernando Henrique Ruppel January 2011 (has links)
Tese (doutorado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2011 / Inclui bibliografias / Os objetivos deste estudo foram avaliar in vitro a dureza e a contração de uma resina composta híbrida pré-refrigerada ou pré-aquecida, fotoativados com aparelhos de luz halógena (QTH) e diodo emissor de luz (LED). Adicionalmente, a temperatura da ponta d / The aim of this study was to evaluate in vitro the hardness and shrinkage of a pre-cooled or pre-heated hybrid composite resin photoactivated by a quartztungsten- halogen light (QTH) and light emitting diode (LED) light-curing units. Additionally, the tem
3

Influência da densidade de energia nas propriedades mecânicas (dureza e módulo de elasticidade) e no aquecimento de uma resina composta fotopolimerizada por LED experimental / Juliana Maria Habith Martin ; orientador, Rui Fernando Mazur ; co-orientador, Paulo César Soares Jr

Martin, Juliana Maria Habith January 2010 (has links)
Tese (doutorado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2010 / Inclui bibliografias
4

Avaliação da transmitância de luz em resinas compostas microhíbridas e nanoparticuladas / Débora Longhi ; orientador, Sérgio Roberto Vieira

Longhi, Débora January 2013 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2013 / Inclui bibliografias / Introdução: A eficiência do processo de fotopolimerização das resinas compostas depende, dentre vários fatores, da composição desta resina e da espessura do incremento a ser polimerizado. O grau de polimerização é proporcional à quantidade de luz a que es / Introduction: The efficiency of photocuring Iargely depends on composite thickness and composition. The degree of curing is proportional to the amount of Iight to which the material is exposed, and varies according to penetration of light in me material.
5

Avaliação in vitro do tempo de fotopolimerização com led de alta potência de bráquetes ortodônticos e remoção de adesivo remanescente sob luz ultravioleta /

Almeida, Layene Figueiredo. January 2016 (has links)
Orientador: Lídia Parsekian Martins / Banca: Ary dos Santos-Pinto / Banca: Alexandre Protásio Vianna / Resumo: OBJETIVO: Avaliar o efeito da redução do tempo de foto polimerização com LED de alta potência (Valo, Ultradent, South Jordan, EUA) na força de adesão de bráquetes metálicos ortodônticos e na quantidade de adesivo remanescente de duas resinas ortodônticas, e avaliar a quantidade de resina remanescente e o dano ao esmalte após a sua remoção com dois métodos distintos de iluminação, sob luz ultravioleta (UV) e sob iluminação artificial convencional. MÉTODOS: Oitenta pré-molares humanos foram divididos em quatro grupos, de acordo com a resina utilizada para a colagem e o tempo de foto polimerização: G1 (Transbond XT, 6s), G2 (Opal Bond MV, 6s), G3 (Transbond XT, 3s) e G4 (Opal Bond MV, 3s). Os bráquetes foram submetidos a um teste de resistência ao cisalhamento em uma máquina de testes universal. A superfície do esmalte foi então fotografada em microscópio eletrônico de varredura e avaliada a quantidade de resina remanescente por meio do software Image J. Os grupos 2 e 4 foram aleatoriamente divididos em dois grupos de acordo com a iluminação utilizada para a remoção da resina residual com broca multilaminada de tungstênio em baixa rotação. O grupo UV recebeu iluminação comum associada à luz UV e o grupo convencional apenas a iluminação convencional. Antes da colagem (T1) e após a remoção da resina (T2), réplicas dos dentes foram fotografados em microscópio eletrônico de varredura com 20 vezes de aumento para a determinação do Enamel Damage Index (EDI) e em T2 foram feitas fotogr... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: OBJECTIVE: To assess the effect of time reduction in bond strenght of metal orthodontics brackets using a high-power LED (Valo, Ultradent, South Jordan, USA) and the amount of adhesive remaining of two orthodontic resins, and assess the amount of adhesive remnant and enamel damage upon removal of an ultraviolet (UV) sensitive adhesive under conventional lighting and UV light. METHODS: Eighty human premolars were divided into four groups, according the composite utilized and light-curing time: G1 (Transbond XT, 6s), G2 (Opal Bond MV, 6s), G3 (Transbond XT, 3s) and G4 (Opal Bond MV, 3s). The brackets were removed by a shear bond strength test on a universal testing machine. After the test, the enamel surface was photographed by scanning electron microscopy and the amount of adhesive remnant was assessed by the Image J software. Groups 2 and 4 were randomly divided into two groups according to the lighting used for the removal of residual resin by a lowspeed tungsten bur. The UV group received conventional lighting associated with UV light, whereas the conventional group received conventional lighting only. Before bonding (T1) and after resin removal (T2), teeth replicas were photographed in a scanning electron microscope for the assess of The enamel damage index (EDI) and on T2 teeth digital photographs were made under UV lighting to assess the amount of resin left over the enamel by Image J software. Two-way analysis of variance was used for statistical analysis of shear bond ... (Complete abstract click electronic access below) / Mestre
6

Influência de fotoiniciadores alternativos na durabilidade da união, adaptação marginal e propriedades físico-químicas de resinas adesivas experimentais fotoativadas por LEDs / Influence of alternative photoinitiators on bond durability, marginal adaptation and physical-chemical properties of experimental adhesive resins photocured by LEDs

Souza Júnior, Eduardo José Carvalho de, 1985- 25 August 2018 (has links)
Orientador: Mario Alexandre Coelho Sinhoreti / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-25T16:27:57Z (GMT). No. of bitstreams: 1 SouzaJunior_EduardoJoseCarvalhode_D.pdf: 1265761 bytes, checksum: 1e110af2f222e502411203feb253160f (MD5) Previous issue date: 2014 / Resumo: O objetivo neste estudo foi analisar o efeito de diodos emissores de luz (LEDs) nas propriedades físicas, químicas, resistência da união (RU), adaptação marginal (AM) e na durabilidade de restaurações realizadas com adesivos experimentais contendo diferentes fotoiniciadores. Uma resina modelo contendo uma mistura de BisGMA/HEMA (60/40 em peso) e dimetil amino etil metacrilato (co-iniciador) foi preparada com os diferentes fotoiniciadores: CQ (Canforoquinona), PPD (1-Fenil-1,2-Propanodiona) e BAPO (Óxido bis-alquil fosfínico), além da associação entre eles. As amostras foram fotoativadas por duas fontes de luz LED, uma de 2° geração (Radii Cal, SDI) e outra de 3° geração (Bluephase G2, Ivoclar Vivadent). A irradiância foi aferida a partir de medidas em potênciômetro e a densidade energética foi padronizada em 48J/cm2. As propriedades avaliadas foram o grau de conversão (GC), cinética de polimerização (CI), análise da permeabilidade dentinária (PMD), sorção (SO) e solubilidade (SL), resistência flexural (RF), módulo flexural (MF) e amarelamento (YL). Para o teste de RU, o ensaio de microtração foi realizado em dentina plana de 70 molares humanos, avaliados após 24 horas e após 1 ano de armazenamento em água a 37ºC. A AM foi mensurada por meio de réplicas das margens superficial e interna de 70 molares humanos, analisadas em microscopia eletrônica de varredura (MEV). Os ensaios de GC, PMD, SO, SL, RF, MF e AM foram submetidos à análise de variância dois fatores, enquanto a RU foi submetida à análise de variância dois fatores (fotoiniciadores e fontes de luz), com medidas repetidas no tempo. Após, todas as médias foram comparadas pelo teste de Tukey ('alfa' = 5%). Os adesivos contendo os fotoiniciadores alternativos, em especial BAPO e BAPO/amina monstraram maior potencial de polimerização, evidenciado pela cinética de conversão. Ainda, os fotoiniciadores alternativos promoveram melhor selamento dentinário, sorção e solubilidade similares e propriedades físico-químicas com melhor desempenho quando comparados aos adesivos convencionais contendo CQ. Em relação à resistência de união, os adesivos contendo BAPO promoveram os melhores desempenhos em até um ano de degradação hidrolítica / Abstract: The aim of this study was to evaluate the effect of light emitting diodes (LEDs) on the physical-chemical properties, bond strength (BS) and marginal adaptation (MA) of experimental adhesives containing diferent photo-initiators. A model resin containing a mixture of BisGMA/HEMA (60/40 wt%) and DMAEMA (co-iniciator) was prepared using different photo-initiators: CQ (Camphorquinone), PPD (1-Phenyl-1,2-Propanedione) e BAPO (Bisalquylphosphine oxide) and their association. The specimens were photoactivated by two LEDs, one monowave (Radii Cal, SDI) and other polywave (Bluephase G2, Ivoclar Vivadent). Irradiance was measured in potenciometer and the energy dose was standardized. The following properties were analyzed: degree of conversion (DC) and for the curing kinetics (CI), dentin permeability (DPM), water sorption (SO), water solubility (SL), flexural strength (FS), flexural modulus (FM) and yellowing (YL). For the BS test, the microtensile test was realized in 70 molars with planned dentin, immediately or after 1-year of water storage. The MA, superficial and internal marginal adaptation measurements were realized by epoxy replicas of the bonded margins using the scanning eléctron microscopy. DC, DPM, SO, SL, FS, FM and AM were submitted to a two-way ANOVA and BS to a two-way repeated measurement ANOVA. Next, the analyzes were submitted to the Tukey¿s test ('alfa' = 5%). The adhesives containing the alternative photoinitiators, such as BAPO and BAPO/amine showed a higher curing potential, promoted by the curing kinetics. Moreover, these alternative photoinitiators showed a better dentin sealing, with similar sorption and solubility values and high physical-mechanical properties when compared to the other groups based in CQ. In relation to the bond strength, the BAPO containing adhesives promoted higher performance even after 1-year of hydrolytic degradation / Doutorado / Materiais Dentarios / Doutor em Materiais Dentários
7

Efeito de fontes de luz LED e condicionamento ácido do esmalte na resistência à microtração, dureza Knoop e formação de fendas de restaurações classe I em compósito utilizando adesivos autocondicionantes / Effect of the LED curing source and enamel acid etching on the microtensile bond strenght, Knoop hardness and gap formation of class I composite restorations using seflf-etch adhesives

Souza Júnior, Eduardo José Carvalho de, 1985- 17 August 2018 (has links)
Orientador: Luís Alexandre Maffei Sartini Paulillo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-17T23:46:46Z (GMT). No. of bitstreams: 1 SouzaJunior_EduardoJoseCarvalhode_M.pdf: 3521538 bytes, checksum: c8b050fbf4fb259c0dc4d1925121d22a (MD5) Previous issue date: 2011 / Resumo: Os objetivos deste estudo foram: a) avaliar o efeito do condicionamento seletivo do esmalte cavosurperficial e da fonte de luz LED na resistência à microtração em dentina de restaurações Classe I em compósito utilizando adesivos autocondicionantes; b) avaliar a dureza Knoop (KHN) de restaurações de cavidades Classe I em compósito utilizando adesivos autocondicionantes fotoativados com diferentes fontes de luz LED; c) Avaliar a formação de fendas antes e após ciclagem termomecânica de restaurações em compósito fotoativadas por LED e utilizando adesivos autocondicionantes em diferentes protocolos de aplicação. No experimento 1, noventa e seis cavidades Classe I foram preparadas em molares humanos, e restauradas com compósito micro-híbrido. Os espécimes foram distribuídos em 12 grupos (n=8), de acordo com a fonte de luz LED (Radii-Cal - RD, Flash Lite 1401 - FL e Ultra-Lume 5 - UL), sistema adesivo autocondicionante (Clearfil SE Bond - CSE e Clearfil S3 Bond - S3) e condicionamento seletivo do esmalte com ácido fosfórico (com e sem). Após o acabamento e polimento das restaurações as mesmas foram submetidas à fadiga termo-mecânica e os palitos para o ensaio de microtração foram obtidos da interface de união entre a parede pulpar dentinária e a restauração. Após o teste mecânico os dados foram submetidos à análise estatística (ANOVA três fatores e teste de Tukey com ?=0.05). O condicionamento seletivo do esmalte para o S3 diminuiu a resistência de união em dentina e não afetou o desempenho do CSE. Além disso, o LED de terceira geração promoveu maiores valores de resistência à microtração para o adesivo de dois passos. Para o S3 as fontes de luz promoveram resistência adesiva semelhante em dentina. No estudo 2, utilizou-se o mesmo método de preparo das amostras do primeiro estudo, formando-se 6 grupos (n=16) pela interação entre os fatores em estudo, LED (RD, FL e UL), sistema adesivo autocondicionante (CSE e S3). As parcelas subdivididas foram diferentes profundidades (superficial, média e profunda). Após a confecção das restaurações, as mesmas também foram submetidas à fadiga termo-mecânica e em seguida, seccionadas no sentido longitudinal para avaliação da KHN nas diferentes profundidades. Após análise estatística (ANOVA dois fatores com parcela subdividida e teste de Tukey com ?=0.05), observou-se que o LED de terceira geração promoveu valores de KHN semelhante aos aparelhos de pico único e que a região superficial, em geral, apresentou melhor qualidade de polimerização. No estudo 3, utilizou-se 192 terceiros molares, onde cavidades Classe I foram preparadas e restauradas com o mesmo método utilizado no primeiro estudo, 12 grupos (n=16) pela interação entre os fatores em estudo, LED (RD, FL e UL), sistema adesivo autocondicionante (CSE e S3) e condicionamento seletivo do esmalte com ácido fosfórico (com e sem), antes e após a termociclagem. Após a restauração, réplicas em resina epóxica foram confeccionadas e as margens foram analisadas em microscópio eletrônico de Varredura (MEV). Após submeter os espécimes da restauração à fadiga termo-mecânica, novamente réplicas em resina epóxica foram feitas e analisadas em MEV. Após análise estatística (Kruskal Wallis e teste de Wilcoxon pareado, ?=0.05), observou-se que o condicionamento seletivo do esmalte promoveu maior integridade marginal para o S3, mostrando ser um passo adicional eficiente na técnica de aplicação desse adesivo em restaurações Classe I em compósito. Além disso, a formação de fendas para adesivo autocondicionante de dois passos não foi influenciado pelo condicionamento ácido prévio do esmalte, nem pelo LED utilizado para fotoativação / Abstract: The aim of this work was to: a) evaluate the effect of enamel selective enamel etching and LED curing units on dentin microtensile bond strength of Class I composite restorations; b) evaluate the effect of different LED light units and self-etch adhesives on the Knoop hardness profile (KHN) of Class I composite restorations; c) evaluate the gap formation before and after thermomechanical loading of Class I composite restorations photocured by LED and using different application protocols of self-etch adhesives systems. In experiment 1, ninety-six Class I cavities were made in human molars and restored with a microhybrid composite. For the restorative procedure, teeth were assigned in 12 groups (n=8) formed by the studied factors interactions, LED curing unit (Radii-Cal - RD, Flash Lite 1401 -FL and Ultra-Lume 5 - UL), self-etch adhesives (Clearfil SE Bond - CSE and Clearfil S3 Bond - S3) and selective enamel acid etching (with and without). After finishing and polishing approach, specimens were submitted to thermo-mechanical ageing and sticks were obtained from the bonding interface between adhesive and pulpal wall which were submitted to a microtensile load in a universal testing machine. After statistical analysis, (three-way ANOVA and Tukey test with ?=0.05) it was shown that the pre-etched enamel approach for Clearfil S3 decreased dentin bond strength while it did not affect the bond performance of Clearfil SE. Thus, the polywave LED promoted higher microtensile bond strength values for the two-step adhesive. When Clearfil S3 was used, the light curing units yielded similar dentin bond strength. In the experiment 2, 96 Class I cavities were prepared in the same way as the previous experiment. Teeth were assigned to 18 groups (n=8) by the interaction among the studied factors, LED curing source (RD, FL and UL), self-etch bond system (CSE and S3), depth (superficial, medium and deep). After the restorative procedure, specimens were submitted to thermo-mechanical ageing and then sectioned in the longitudinal direction for the Knoop hardness measurement in the different depths. Data were submitted to three-way ANOVA and Tukey test with a pre-set alpha of 0.05). The results showed that the third generation LED promoted similar KHN values to the single-peak ones and the superficial surface, in general, presented greater cure quality compared to the others surface depths. In the experiment 3, 192 third molars were used and Class I preparations were restored in the same way as the first study. Specimens were assigned to 12 groups (n=16) formed by the studied factors interaction, LED (RD, FL and UL), self-etch adhesives (CSE and S3), selective enamel acid etching (with and without) and before and after thermomechanical loading. After the restoration procedure, epoxy resin replicas were made and the marginal adaptation was analyzed in a scanning electron microscope (SEM). Then specimes were submitted to thermalmechanical loading and again, epoxy resin replicas were made and analyzed by SEM. After statistical analysis (Kruskal Wallis and Wilcoxon matched-pairs signed-ranks test, with a pre-set alpha of 0.05), it was shown that selective enamel etching yielded higher marginal integrity for S3, showing to be an efficient additional step for the bonding technique of this adhesive in Class I composite restorations. Also, the two-step self-etch adhesive gap formation was not influenced by the selective enamel etching, neither by the LED curing light / Mestrado / Dentística / Mestre em Clínica Odontológica
8

Efeito da contaminação por primer e pelo excesso de água, álcool ou clorexidina nas propriedades mecânicas e cinética de conversão de sistemas adesivos convencionais / Effect of contamination by primer and the water, ethanol or chlorexidine excess on mechanical properties and real time conversion of conventional adhesives systems

Humel, Maria Malerba Colombi, 1983- 21 August 2018 (has links)
Orientador: Luís Alexandre Maffei Sartini Paulillo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-21T22:44:51Z (GMT). No. of bitstreams: 1 Humel_MariaMalerbaColombi_D.pdf: 11561780 bytes, checksum: 79e3ed8605dc03bf07a59b8bb75596c5 (MD5) Previous issue date: 2013 / Resumo: Este estudo teve como objetivo avaliar a influência de diferentes concentrações destas soluções na resistência à flexão (FS), módulo de Elasticidade (E) e grau de conversão (DC) de sistemas adesivos convencionais, e ainda, sua influência na cinética (K) e taxa de conversão (RP). Para isso foram realizados dois trabalhos experimentais, sendo que no primeiro avaliaram-se as quantidades de primer nos adesivos, e no segundo trabalho avaliou-se a influência das soluções de enxague de cavidade, água, EtOH e CHX, quando em excesso, nos sistemas adesivos. Para se avaliar as diferentes concentrações do primer residual dois adesivos foram manipulados, M1 e M2 e testados com quatro concentrações de primer: 0, 5, 10 e 15%. Já para se avaliar o excesso de água, EtOH e CHX, dois adesivos foram testados: M1, adesivo manipulado, e o adesivo comercial SBMP; diluídos com 0, 2 e 9% para cada uma das soluções. Para se avaliar as propriedades mecânicas, nos dois estudos, foram preparadas amostras a partir de moldes de silicone em forma de barras (7 x 2 x 1mm) e após armazenamento por 24h, foram testadas em máquina de ensaio mecânico para o teste de FS a uma velocidade de 0,5 mm/min. DC foi mensurado utilizando Espectroscopia Transformada Infravermelha de Fourier (FTIR). Para cinética de conversão, a polimerização em cada diluição foi monitorada por FTIR pelo tempo de 60s, sendo que a conversão foi calculada a cada dois 2s de polimerização, avaliando-se também RP. No primeiro estudo, as diferentes concentrações da diluição com primer não mostrou diferença no teste de FS entre os adesivos testados, independente da concentração avaliada. Os dois adesivos testados apresentaram redução nos valores de DC com o aumento das quantidades de primer, sendo o adesivo M2 o mais susceptível às diluições. No segundo trabalho, para as diluições com água, EtOH, independente da quantidade testada, uma redução nas propriedades mecânicas e DC puderam ser observadas. As diluições em água e CHX alteraram mais as propriedades mecânicas quando comparadas as diluições com EtOH. Para K e RP com o aumento da concentração de primer residual todos adesivos apresentaram redução quando se avaliou os gráficos de conversão. Para as diluições em água, o aumento de sua concentração levou a queda progressiva na K e as diluições com CHX apresentaram menor influência na K, com redução apenas para 9% de diluição. Porém, para as diluições em EtOH houve aumento na K e RP especialmente para o adesivo SBMP. Assim, para o primeiro estudo, os resultados sugerem que as diferentes quantidades de primer usadas na diluição do adesivo não influenciam as propriedades mecânicas dos adesivos testados, porém, interferem na sua reação química de polimerização, uma vez que a velocidade reação foi reduzida (K e RP). Por outro lado, no segundo estudo, para as soluções residuais de água, EtOH e CHX, uma diminuição nas propriedades mecânicas dos adesivos ocorreu somente quando quantidades residuais de 9% foram simuladas. No entanto, pequenas quantidades de EtOH e CHX parecem não afetar as propriedades e velocidade de reação de polimerização dos adesivos / Abstract: The present study evaluates the influence of these solutions in different concentrations on flexural strength (FS), elastic modulus (E) and degree of conversion (DC) of conventional adhesives evaluating also the kinetic of conversion (K) and rate of polymerization (RP). Two distinct experiments were plotted, the first one evaluating the primer amount diluted in adhesives, and the second experiment evaluating rinse solutions amounts like water, ethanol and chlorexidine diluted in different adhesives. For different concentrations of primer solutions, two manipulated adhesives; M1 and M2 were tested at 0, 5, 10 and 15% of dilution. For different concentrations of water, ethanol (EtOH) and chlorexidine (CHX) dilutions, two adhesives were evaluated: M1, a manipulated adhesive, and the SBMP; diluted at 0, 2 and 9% of dilutions. Both studies, for mechanical properties, specimens were obtained by silicon mold bars (7 x 2 x 1mm), and after 24h, FS were performed at Mechanical Test Machine at cross speed of 0.5 mm/min. DC were measured with a Fourier Transformed Infrared Spectroscopy (FTIR). For K test, Infrared Spectroscopy monitored each 2 seconds of conversion for 60sec of polymerization, and the RP were evaluated. The first experiment, for different concentrations of primer dilutions, the FS for all adhesives tested was not affected by primer concentrations. All adhesives tested showed a decrease for DC as increased the primer dilution, with M2 presenting as the most sensitive for primer concentration. For second experiment, for all concentrations dilution of water, EtOH and CHX, a decrease on mechanical properties and DC was noted. Water and chlorexidine seems to affect more mechanical properties when compared to EtOH results. For K and RP results, increasing primer concentration, all adhesives presented a decrease of conversion and RP. For water dilutions, increasing water concentrations on tested adhesives, a progressive decrease could be noted on K graphics. CHX dilutions presented less influence on K, with decreasing RP and K only with 9% dilution. Although, EtOH dilutions presented an improve K as the RP, especially to SBMP adhesive. The results suggested that mechanical properties were not affected regardless of the primer amount diluted on adhesives, interfering only on chemistry of polymer reaction, once reaction speedy were affected (K and RP). However, for second experiment, a decrease on mechanical properties of adhesive solutions could be noted only when extreme amounts of residual solution where diluted. Notwithstanding, at lowest concentrations, EtOH and CHX seems not interfere on K and RP of adhesives / Doutorado / Dentística / Doutora em Clínica Odontológica
9

Comportamento clínico de restaurações classe I e II de resina composta realizadas com sistema adesivo universal em diferentes protocolos de aplicação - estudo clínico randomizado / Clinical performance of composite resin vlass I and II conducted with a universal adhesive system in different application protocols - randomized clinical study

Carvalho, Andreia Assis 20 April 2018 (has links)
Submitted by JÚLIO HEBER SILVA (julioheber@yahoo.com.br) on 2018-05-22T17:33:36Z No. of bitstreams: 2 Tese - Andreia Assis Carvalho - 2018.pdf: 4561805 bytes, checksum: 5562226572f75d161d963c396d0c974f (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2018-05-23T11:38:00Z (GMT) No. of bitstreams: 2 Tese - Andreia Assis Carvalho - 2018.pdf: 4561805 bytes, checksum: 5562226572f75d161d963c396d0c974f (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-05-23T11:38:00Z (GMT). No. of bitstreams: 2 Tese - Andreia Assis Carvalho - 2018.pdf: 4561805 bytes, checksum: 5562226572f75d161d963c396d0c974f (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2018-04-20 / Fundação de Amparo à Pesquisa do Estado de Goiás - FAPEG / The objective of this study was to evaluate the clinical behavior of direct composite resin restorations (Class I and II), varying the universal dental adhesive application protocol, using the FDI and USPHS evaluation criteria. It was a randomized, double-blind, mouth5 divided, and sample-based randomized controlled trial. The selected participants should have a Class I and/or II restorative need for at least three dental elements or multiples of three resulting from the presence of carious lesions and/or unsatisfactory restorations. Three protocols for the application of the Single Bond Universal adhesive (3M ESPE) were tested (n=150): CAT (control) = etch-and-rinse + adhesive (n=50); CASE = selective etching in enamel + adhesive (n=50) and Ac = self-etch (n=50). The three groups were similarly restored using Filtek Z350 XT composite resin (3M ESPE) by means of the oblique incremental technique. Clinical evaluations were performed by two evaluators at the baseline (T1) and after 15.8 (±2.7 months) (T2), using the FDI and USPHS criteria. Friedman (between groups at different times), Wilcoxon (between times for each group) and McNemar (between FDI and USPHS criteria) were performed, α=0.05. The Kappa test showed excellent inter-examiner agreement (κ>0.80). For the "superficial staining" property, a statistically significant difference was observed in T2 between the CAT and CASE groups (p=0.01) with higher values for CAT and, when T1 and T2 were compared for each group, there were differences in the CAT group (p=0.001) and in the Ac group (p=0.007) for T2. For the other comparisons between groups and times there were no statistically significant differences, even when the FDI and USPHS criteria were compared (p≥0.05). It can be concluded that the different protocols of universal adhesive application (CAT, CASE and Ac) did not influence the clinical behavior of the restorations evaluated in 15.8 months of evaluation. The FDI and USPHS criteria provided comparable results. / Esse trabalho objetivou avaliar o comportamento clínico de restaurações diretas de resina composta (Classe I e II), variando o protocolo de aplicação do adesivo dentário universal, por meio dos critérios de avaliação FDI e USPHS. Trata-se de um ensaio clínico contrlado randomizado, duplo-cego, boca-dividida e de amostra por conveniência. Os participantes selecionados deveriam ter necessidade restauradora de Classe I e/ou II no mínimo em três elementos dentários ou múltiplos de três, resultantes da presença de lesões cariosas e/ou restaurações insatisfatórias. Três protocolos de aplicação do adesivo Single Bond Universal (3M ESPE) foram testados (n=150): CAT (controle) = Condicionamento ácido total + adesivo (n=50); CASE = Condicionamento ácido seletivo em esmalte + adesivo (n=50) e Ac = autocondicionante (n=50). Os três grupos foram restaurados de forma similar utilizando resina composta Filtek Z350 XT (3M ESPE) por meio da técnica incremental oblíqua. As avaliações clínicas foram realizadas por dois avaliadores no baseline (T1) e após 15,8 (±2,7 meses) (T2), por meio dos critérios FDI e USPHS. Foram realizados os testes Friedman (entre os grupos nos diferentes tempos), Wilcoxon (entre os tempos para cada grupo) e McNemar (entre os critérios FDI e USPHS), α=0,05. O teste Kappa apresentou excelente concordância interexaminadores (κ>0,80). Para a propriedade “manchamento superficial”, observou-se diferença estatisticamente significante no T2 entre os grupos CAT e CASE (p=0,01) com maiores valores para CAT e, quando comparados T1 e T2 para cada grupo, houve diferença no grupo CAT (p=0,001) e no grupo Ac (p=0,007) para T2. Para as demais comparações entre os grupos e tempos não houve diferenças estatisticamente significantes, inclusive quando os critérios FDI e USPHS foram comparados (p≥0,05). Pode-se concluir que os diferentes protocolos de aplicação do adesivo universal (CAT, CASE e Ac) não influenciaram o comportamento clínico das restaurações avaliadas em 15,8 meses de avaliação. Os critérios FDI e USPHS proporcionaram resultados comparáveis entre si.
10

Protótipo de ponteira acoplada aos aparelhos fotopolimerizadores para colagem de bráquetes e acessórios ortodônticos

Mota Júnior, Sergio Luiz 14 February 2012 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-05-18T14:18:46Z No. of bitstreams: 1 sergioluizmotajunior.pdf: 65970440 bytes, checksum: b08afa740679beb93b85550945b417d2 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-07-01T18:47:10Z (GMT) No. of bitstreams: 1 sergioluizmotajunior.pdf: 65970440 bytes, checksum: b08afa740679beb93b85550945b417d2 (MD5) / Made available in DSpace on 2016-07-01T18:47:10Z (GMT). No. of bitstreams: 1 sergioluizmotajunior.pdf: 65970440 bytes, checksum: b08afa740679beb93b85550945b417d2 (MD5) Previous issue date: 2012-02-14 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo do presente estudo foi o desenvolvimento de uma nova ponteira para ser acoplada aos aparelhos fotopolimerizadores utilizados para colagem de bráquetes e acessórios ortodônticos, e teste da efetividade da mesma em ensaio mecânico in vitro. A ponteira é espelhada na superfície interna e baseia-se em conceitos físicos de refração e reflexão de luz. Apresenta como principal vantagem, a redução do tempo clínico necessário para o procedimento de colagem, reduzindo, dessa forma, a possibilidade de contaminação durante o processo. Através do ensaio de resistência mecânica ao cisalhamento e da determinação do Indice Remanescênte de Adesivo (IRA), testou-se a ponteira em uma amostra composta por 120 corpos de prova, sendo a mesma dividida em 2 grupos. No grupo 1 foi utilizado aparelho fotopolimerizador de fonte de luz halógena e no grupo 2 foi utilizado fonte de LED. Cada grupo foi subdividido. Nos subgrupos H1 e L1 utilizou-se a ponteira convencional dos respectivos instrumentos. Nos subgrupos H2 e L2 a colagem foi feita utilizando-se a ponteira desenvolvida. Os valores dos testes de cisalhamento e IRA para os subgrupos foram comparados entre si. Os resultados mostraram que não houve diferença estatisticamente significante, tanto para os ensaios de resistência ao cisalhamento (p>0,05), quanto para o IRA (p>0,05) entre os subgrupos. Conclui-se que 1 - os testes de ensaios mecânicos, assim como a análise do IRA mostraram que a nova ponteira desenvolvida, cumpriu os requisitos necessários à colagem dos acessórios ortodônticos; 2 – o tempo de colagem foi reduzido pela metade, sendo necessária uma só incidência. / The porpose of the present study was the development of a new device to be coupled to light-curing units for bonding orthodontic brackets and accessories and test of its efficacy in “in vitro” mechanical trial. The inner surface of the device is mirrored and is based on physical concepts of light refraction and reflection. The main advantage of such device is the reduced clinical time needed for bonding and the lesser possibility of contamination during the process. 120 bodies of proof were used for testing the shear bond strength of brackets bonded with the device. The Adhesive Remnant Index (ARI) was also determined. The sample was divided into 2 groups. In group 1 a halogen light-curing unit was used and in group 2 a led lightcuring unit was used. Each group was then subdivided. In subgroups H1 and L1, a conventional light guide rod was used. In subgroups H2 and L2 bonding was performed with the mirrored device coupled to the tip of the guide light rod. The values obtained for the shear bond strength and the ARI in the subgroups were compared. Results showed that there was no statistically significant difference for the shear strength (p>0,05) and the ARI (p>0,05) between the subgroups. Conclusions are that 1 - The tests of mechanical trials and the ARI analysis showed that the new device fulfilled the requisites for bonding orthodontic accessories; 2 - time for bonding was reduced to half, being necessary only one light exposure.

Page generated in 0.1506 seconds