• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 32
  • Tagged with
  • 32
  • 20
  • 19
  • 14
  • 13
  • 12
  • 9
  • 9
  • 8
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Equipamento fotoativador de resinas odontológicas dotado de um controlador eletrônico de intensidade luminosa / Optimization of the dimming function in curing processes of dental composite resins for minimizing polymerization shrinkage

Marcelino, Edilmar [UNESP] 25 November 2016 (has links)
Submitted by EDILMAR MARCELINO null (edilmar.marcelino@ig.com.br) on 2016-12-11T09:47:15Z No. of bitstreams: 1 Dissertação Entrega Repositório.pdf: 322258 bytes, checksum: 34e349ec26025ec5badffd78e205e747 (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2016-12-20T13:26:09Z (GMT) No. of bitstreams: 1 RESSALVA - patente.pdf: 265502 bytes, checksum: 6d6a2a3e271d5b3dcff4276078136352 (MD5) / Made available in DSpace on 2016-12-20T13:26:09Z (GMT). No. of bitstreams: 1 RESSALVA - patente.pdf: 265502 bytes, checksum: 6d6a2a3e271d5b3dcff4276078136352 (MD5) Previous issue date: 2016-11-25
2

Obtenção e caracterização de pontos quânticos fluorescentes de ZnSe:Mn

Gomes da Silva, Thiago 31 January 2011 (has links)
Made available in DSpace on 2014-06-12T16:30:18Z (GMT). No. of bitstreams: 2 arquivo2760_1.pdf: 3153009 bytes, checksum: ef8ea72f8f3bc4c6ed0c6859638cf005 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2011 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / Nanocristais de semicondutores do tipo II-VI, dentro do regime de confinamento quântico, conhecidos como pontos quânticos (quantum dots) surgiram há mais de uma década e mostram-se como uma importante ferramenta de marcação biológica. Atualmente busca-se, através da dopagem destes materiais semicondutores, melhorias e mudanças em suas propriedades ópticas e magnéticas. Neste trabalho, apresenta-se uma metodologia de obtenção de pontos quânticos fluorescentes de seleneto de zinco (ZnSe) dopados e não dopados com manganês (ZnSe:Mn). As reações empregaram técnicas de química coloidal em meio aquoso e métodos pós-preparativos envolvendo fotoativação com radiação ultravioleta. Foi realizado um planejamento fatorial tipo 22 para verificar as melhores condições de reação de obtenção que resultam no aumento da intensidade da emissão na região do vermelho (acima de 580 nm) para o nanocristal dopado, variando a concentração do íon Mn2+ e a dose de radiação no processo de fotoativação. O tamanho médio dos nanocristais (d~3 nm), e sua cristalinidade foram estimados utilizando-se as técnicas de espectroscopia de absorção eletrônica, microscopia eletrônica de transmissão e pela técnica de difração de Raios-X. A caracterização óptica foi realizada empregando-se espectroscopia de emissão e excitação eletrônica determinando-se os processos ópticos envolvidos. As suspensões de ZnSe não dopados, sob excitação entre 300 e 370 nm, apresentam alta intensidade de luminescência com máximo observado na região do azul (lmax = 400) e banda larga na região do verde (lmax =460 nm). Os nanocristais dopados apresentaram a emissão típica do Mn2+ na região do vermelho (lmax = 580 nm) quando excitado em lexc= 400 nm. O planejamento fatorial realizado mostrou que o fator que mais contribui na emissão do íon Mn2+ é sua concentração no processo de síntese. A quantificação do Mn2+ nos nanocristais foi realizada por técnica de Plasma Indutivamente Acoplado e mostrou que foi incorporado um valor máximo de 0, 89% de íons Mn2+ nos nanocristais de ZnSe, o que representa 18% do valor adicionado inicialmente na síntese
3

Metacrilato piperonílico: coiniciador copolimerizável para composição de sistemas de polimerização fotoiniciada / Piperonyl methacrylate: coinitiator copolymerizable for the composition of system of polymerization photoinitiated

Moreira, Andressa Goicochea 29 March 2017 (has links)
Submitted by Márcio Ropke (ropke13marcio@gmail.com) on 2017-07-12T12:38:06Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Metacrilato piperonílico coiniciador copolimerizável para composição de.pdf: 1224200 bytes, checksum: aaa0f95ab36381591948e0528869f28c (MD5) / Made available in DSpace on 2017-07-12T12:38:06Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Metacrilato piperonílico coiniciador copolimerizável para composição de.pdf: 1224200 bytes, checksum: aaa0f95ab36381591948e0528869f28c (MD5) Previous issue date: 2017-03-29 / Sem bolsa / A evolução dos materiais odontológicos vem contribuindo para que se consiga al-cançar a excelência em procedimentos estéticos. Diversos fatores clínicos motivam novos estudos para desenvolvimento de materiais que consigam atingir proprieda-des ópticas, mecânicas e biológicas semelhantes ao elemento dental. Assim, esta pesquisa busca contribuir para a evolução desses materiais por meio de estudos in vitro. Portanto os objetivos deste trabalho foram realizar a síntese de uma molécula, o metacrilato piperonílico, por meio de uma rota de sintese alternativa à utilização do cloreto de metacriloila, com tocixidade conhecida, e analisar se essa moléula possui potencial de atuação como um coiniciador alternativo copolimerizável para composi-ção de sistemas de polimerização radicalar fotoiniciada com tecnologia de alto de-sempenho e biocompatibilidade. Para a síntese do metacrilato piperonílico, o álcool piperonílico foi esterificado utilizando o anidrido metacrilato. O produto obtido foi pu-rificado e posteriormente submetido à ressonância magnética nuclear protônica e espectroscopia no infravermelho para confirmação da estrutura. Adesivos convenci-onais foram desenvolvidos utilizando uma resina adesiva modelo, composta por 50% de bisfenol a glicidil metacrilato (Bis-GMA), 25% de 2-hidroxietil metacrilato (HEMA) e 25% de trietilenoglicol dimetacrilato (TEGDMA). Canforoquinona (CQ) na concen-tração 1% molar foi utilizada como fotoiniciador da polimerização da resina modelo, a qual foi adicionada de diferentes coiniciadores constituindo os seguintes grupos experimentais: metacrilato piperonílico (PipeM Adesivo) e EDAB (EDAB Adesivo) constituindo sistemas binários de fotoativação. Adicionalmente um grupo com adesi-vo de referência comercial Scotch Bond Multi Purpouse - 3M (SBMP Adesivo) foi avaliado. As propriedades físico-químicas, mecânicas, microbiologicas e biológicas do polímero formado pelos adesivos experimentais foram avaliadas utilizando as metodologias de cinética e taxa de polimerização, resistência à mini-flexão, módulo de elasticidade, sorção e solubilidade, resistência de união ao microcisalhamento 10 (MPa) em esmalte e dentina bovina, caracterização da camada híbrida em micros-cópio eletrônico de varredura (MEV), teste antimicrobiano de contato direto modifi-cado e avaliação da sua citotoxidade. Os resultados obtidos foram tabulados e a análise estatística realizada de acordo com o ensaio. O PipeM adesivo apresentou maior grau de conversão, menor sorção e solubilidade em água quando relacionado aos demais grupos. O grupo PipeM foi semelhante apenas ao grupo EDAB no teste de resistência de união ou microcisalhamento em dentina. Em todos os outros tes-tes, os grupos foram semelhantes (p <0,05). A porcentagem de viabilidade celular avaliada após 24h mostrou que os grupos experimentais foram semelhantes à refe-rência comercial apresentando viabilidade celular próxima de 100%. Em suma o me-tacrilato piperonílico apresentou desempenho semelhante ou superior à amina terci-ária, com a vantagem de apresentar maior biocompatibilidade em função de seu po-tencial de copolimerização, representando ser um coiniciador alternativo para com-posições fotopolimerizáveis. / The evolution of dental materials has been contributing to their success in cosmetic procedures. Several clinical factors motivate new studies to develop materials that achieve optical, mechanical and biological properties similar to the dental element. Thus, this research seeks to contribute to the evolution of these materials through in vitro studies. Therefore, the objectives of this work are to carry out the synthesis of a molecule, piperonyl methacrylate, by means of an alternative route to the use of methacryloyl chloride, with known toxicity, and to analyze if this molecule has poten-tial of acting as an alternative copolymerizable coinitiator for the composition of radi-cal polymerization systems photoinitiated with technology of high performance and biocompatibility. For the synthesis of piperonyl methacrylate, piperonyl alcohol was esterified using methacrylic anhydride. The product obtained was purified and sub-sequently subjected to proton magnetic resonance and infrared spectroscopy to con-firm the structure. Conventional adhesives were developed using an adhesive resin model, composed of 50% bisphenol A glycidyl methacrylate (Bis-GMA), 25% 2-hydroxyethyl methacrylate (HEMA) and 25% triethyleneglycol dimethacrylate (TEGDMA). Canforquinone (CQ) at 1 mol% concentration was used as a photoinitia-tor of the polymerization of the model resin, which it was added with different co-initiators constituting the following experimental groups: piperonyl methacrylate (Pi-peM Adhesive) and EDAB (EDAB Adhesive), constituting binary photoactivation sys-tems. In addition, the Scotch Bond Multi Purpose-3M commercial reference adhesive (SBMP Adhesive) was evaluated. The physicochemical, mechanical, microbiological and biological properties of the polymer formed by the experimental adhesives were evaluated using polymerization kinetics methodologies, mini-flexural strength, modu-lus of elasticity, water sorption and solubility, enamel and dentin micro-shear bond strength (MPa) and performed the characterization of the hybrid layer under scanning electron microscope (SEM), Modified direct contact antimicrobial test and evaluation 12 of its cytotoxicity. The results obtained, were tabulated and the statistical analysis performed according to the assay. The PipeM adhesive showed a higher degree of conversion, lower sorption and solubility in water when related to the other groups. The PipeM group was similar only to the EDAB group in the bond strength test or dentin microcracking. In all other tests, the groups were similar (p <0.05). The percentage of cell viability evaluated after 24h showed that the experimental groups were similar to the commercial reference, presenting cell viability close to 100%. In summary, the piperonyl methacrylate presented similar or superior perfor-mance to the tertiary amine, with the advantage of presenting greater biocompatibil-ity as a function of its copolymerization potential, being an alternative co-initiator for photopolymerizable compositions.
4

Avaliação in vitro da eficácia da fotoativação no clareamento dental utilizando a técnica em consultório

Araújo, Rodrigo Maximo de [UNESP] 12 June 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:00Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-06-12Bitstream added on 2014-06-13T21:05:37Z : No. of bitstreams: 1 araujo_rm_dr_sjc.pdf: 355643 bytes, checksum: bf7137e386ce1c8e17589f337e9e1a65 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar se fontes de luz aumentam a eficácia do peróxido de hidrogênio na técnica de clareamento profissional. Para tal, 60 dentes incisivos bovinos foram extraídos e limpos com lâminas de bisturi. As dimensões coronárias e radiculares foram padronizadas a partir do limite amelo-cementário, procedendo-se os devidos cortes perpendiculares na região incisal e apical. A porção lingual foi removida por corte longitudinal, recebendo a superfície vestibular uma profilaxia com jato de bicarbonato de sódio, sendo a porção dentinária exposta, condicionada com H3PO4 a 38% por 15s. Os corpos-de-prova foram levados a um banho de água em ultra-som por 20 min e a seguir imersos em solução de café solúvel a 25%, por duas semanas. A seguir, a porção dentinária foi impermeabilizada com esmalte para unhas incolor e a face vestibular polida com pasta de óxido de alumínio e disco de feltro. Os corpo-de-prova foram divididos aleatoriamente em 5 grupos, sendo a cor inicial mensurada através do espectrofotômetro-EasyShade (VITA-Zahnfabrik, Bad Sackingen, Alemanha ). Todos os corpos-de-prova receberam três aplicações por 15 min do gel clareador Opalescence Xtra-Boost (Ultradent South Jordan, UT, USA). O grupo 1 não recebeu fotoativação, sendo considerado controle, grupo 2 foi ativado com um fotopolimerizador de luz halôgena, grupo 3 ativado com aparelho híbrido de LED azul /LASER, grupo 4 ativado com aparelho de LED verde /LASER e grupo 5 ativação com LED vermelho. Após o clareamento foi novamente mensurada a cor. Os dados de variação de cor ΔE, Δa*, Δb*e ΔL* e os referentes a escala de cor Vita Clássico, foram submetidos a análise de variância e teste de Tukey e Dunn ( p = 5%). Concluimos que: o desempenho do peróxido de hidrogênio a 38 %, teve seu efeito intensificado conforme a fonte de luz utilizada;a diferença... / The aim of this in vitro study was to evaluate of the Light Activations of in office bleaching agent technique increase the effectiveness of the procedure, measured by the change of teeth’s color. In this study, 60 bovine incisor teeth were extracted, specimen’s size was standardized and dentin portion was exposed by carburundum disks. All the surfaces received a sodium bicarbonate prophylaxis and then conditioned by 38% phosphoric acid during 15s. The samples were then brought to a water bath in ultrasound for 20 min and immersed in a 25% soluble coffee solution for two weeks period. Then, the portion dentin was polished with felt’s disk and aluminium oxide paste, and finally sealed with colorless ink nail. The specimens were randomly divided into 5 groups, and the original color measured by spectrophotometer - EasyShade (VITA-Zahnfabrik, Bad Sackingen, Germany). All specimens received three applications of bleaching agent Opalescence Xtra-Boost (Ultradent South Jordan, UT, USA) during a period of 15 min each. Group 1 did not receive light activation and was considered as a Control Group, Group 2 was activated with a Halogen light (15 min), Group 3 was activated with hybrid of blue LED / Laser (15 min), Group 4 was activate with green LED / Laser (15min) and Group 5 activated with red Laser (15 min). The color was measured again after bleaching in all specimens. The data of changing color variation ΔE, Δa*, Δb* and ΔL* and those references on Vita Classic, were subjected to ANOVA, Tukey's test and Dunn (p = 5%). The performance of hydrogen peroxide 38% was affected by the source of light used. Significantly differences in reduction of color were observed with all light activators employed and particularly with the blue LED light and Halogen. Quantitative... (Complete abstract click electronic access below)
5

Desenvolvimento de processos de bioconjugação empregando pontos quânticos fluorescentes de semicondutores II-VI

Gonçalves Brasil Júnior, Aluizio 31 January 2010 (has links)
Made available in DSpace on 2014-06-12T16:24:35Z (GMT). No. of bitstreams: 2 arquivo1066_1.pdf: 3918967 bytes, checksum: ae17612cf0dabcaa76051e66522c7c80 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2010 / Fundação de Amparo à Ciência e Tecnologia do Estado de Pernambuco / A pouco mais de uma década surgiu uma nova classe de marcadores fluorescentes baseados em nanocristais de semicondutores do tipo II-VI conhecidos como pontos quânticos (quantum dots). Neste trabalho, apresentam-se metodologias de obtenção de pontos quânticos fluorescentes de semicondutores do tipo core/shell de ZnSe/ZnS e CdS/Cd(OH)2 através de técnicas de química coloidal em meio aquoso. O tamanho médio dos nanocristais (ZnSe = 3 nm e CdS = 6 nm) foi estimado utilizando-se as técnicas de espectroscopia de absorção na região do ultravioleta-visível, microscopia eletrônica de transmissão convencional e pela técnica de difração de Raios-X. A caracterização das propriedades ópticas foi realizada empregando-se espectroscopia de emissão e excitação eletrônica. Os sistemas apresentam alta intensidade de luminescência com máximos observados na região do azul para o ZnSe/ZnS e do verde para o CdS/Cd(OH)2. Para otimização de sua emissão os pontos quânticos de ZnSe/ZnS foram submetidos a processo de fotoativação, com radiação ultravioleta. Ambos sistemas foram bioconjugados à proteína albumina sérica bovina (BSA), empregando-se agentes de comprimento zero (carbodiimidas) para os pontos quânticos de ZnSe/ZnS e o crosslinker glutaraldeído para o CdS/Cd(OH)2. Foram desenvolvidos e avaliados protocolos de bioconjugação para os dois pontos quânticos, a fim de se estabelecer os mais eficazes. Os bioconjugados foram caracterizados através de técnicas espectroscópicas e confirmados pela detecção quantitativa da intensidade de fluorescência, empregando-se microplacas de poliestireno como substrato. Foi evidenciado por meio da técnica de dicroísmo circular, que a estrutura secundária da proteína foi preservada. Os espectros de luz polarizada da biomolécula conjugada aos pontos quânticos de CdS/Cd(OH)2, apresentaram alterações mínimas em relação ao padrão não conjugado, enquanto que os conjugados aos pontos quânticos de ZnSe/ZnS exibiram alterações estruturais significativas. Os bioconjugados obtidos podem ser considerados protótipos na preparação de imunocomplexos baseados em ligantes bioespecíficos, visando o desenvolvimento de imunoensaios heterogêneos para o diagnóstico sorológico de doenças.
6

Efeito de diferentes doses de energia de unidades LED uni- e multi-ondas nas propriedades mecânicas de Resinas Compostas

Souza, Ana Maria de 10 December 2013 (has links)
Submitted by Nadir Basilio (nadirsb@uninove.br) on 2015-07-21T15:07:51Z No. of bitstreams: 1 Ana Maria de Souza.pdf: 717565 bytes, checksum: 0b6ad0f4adba71695d0147808fdc405c (MD5) / Made available in DSpace on 2015-07-21T15:07:51Z (GMT). No. of bitstreams: 1 Ana Maria de Souza.pdf: 717565 bytes, checksum: 0b6ad0f4adba71695d0147808fdc405c (MD5) Previous issue date: 2013-12-10 / The aim of the present study was to evaluate the influence of different doses of energy and uni- or multi-wave LED units on mechanical properties of composite resins. Thereunto, six experimental groups were established for each assessed resin (IPS Empress Direct - Ivoclar Vivadent , Venus - Heraeus - Kulzer , SDR - Dentsply) according to the different different amounts of energy (5J , 10J and 20J) and LED unit (bluephase 16i and bluephase G2 - Ivoclar Vivadent) . Thirty six specimens were prepared (7mm long x 2mm wide x 1mm height) from silicon matrices and were used for evaluation of mechanical properties (flexural strength and modulus of elasticity) using the three points bending test, in a universal testing machine at a speed of 0.5 mm/min until the specimens fracture. Data were tested for normality and then the two-way analysis of variance was applied and Tukey's test was used to point out differences among means, with significance level set at 5%. Thus, the results showed that the resins presented different performance by energy amounts and by the difference of the spectra of light emitted by different sources. It appears from the data presented that the factors studied in this work are directly related to the mechanical properties of resin composites. / O objetivo do presente estudo foi avaliar a influência de diferentes doses de energia e unidades LED fotoativadoras de banda estreita e com amplo espectro nas propriedades mecânicas de resinas compostas. Para isso, 6 grupos experimentais foram estabelecidos para cada resina avaliada (IPS Empress Direct – Ivoclar Vivadent, Venus – Heraeus-Kulzer, SDR - Dentsply), de acordo com as diferentes doses de energia (5J; 10J e 20J) e unidades fotoativadoras (Bluephase 16i e Bluephase G2 – Ivoclar Vivadent). Trinta e seis corpos-de-prova foram confeccionados (7mm comprimento X 2mm largura X 1mm de altura) a partir de matrizes de silicone e foram utilizados para avaliação das propriedades mecânicas (resistência à flexão e módulo de elasticidade) utilizando o teste de flexão de três pontos, em máquina de ensaio universal a uma velocidade de 0,5 mm/min até que ocorresse a fratura do corpo-de-prova. Os dados foram avaliados quanto à sua normalidade e então, aplicado a Análise de Variância a dois critérios e teste de Tukey, com nível de significância fixado em 5%. Os resultados mostraram que as resinas apresentaram comportamentos diferentes entre si tanto pelas doses de energia utilizadas quanto pela diferença dos espectros de luz emitidos pelas diferentes fontes. Conclui-se dos dados apresentados que os fatores estudados neste trabalho têm relação direta com as propriedades mecânicas dos compósitos resinosos.
7

Influência das unidades fotoativadoras e do material restaurador indireto sobre a dureza de um cimento resinoso dual auto-adesivo e um cimento resinoso dual convencional por meio de teste de nanoendentação / Influence of curing units and restorative indirect material on hardness of a dual cure self-adhesive resin cement and dual cure conventional resin cement through nanoindentadion test

Kuguimiya, Rosiane Nogueira 05 December 2013 (has links)
O objetivo deste estudo foi avaliar a dureza de um cimento resinoso dual autoadesivo (RelyX U200) e um cimento resinoso dual convencional (RelyX ARC) fotoativados sob materiais restauradores indiretos, utilizando unidades fotoativadoras com diferentes comprimentos de ondas (LED Elipar Freelight 2, LED Bluephase, Laser AccuCure 3000TM), por meio de teste de nanoendentação. Para a obtenção dos espécimes foram utilizados incisivos bovinos que após profilaxia, foram submetidos a cortes no limite amelo-cementário para a separação da porção coronária. Após inclusão, os espécimes foram submetidos ao desgaste para exposição de dentina e padronização do substrato. Para simular clinicamente restaurações indiretas foram confeccionadas peças em cerâmica IPS e.max® Press (Ivoclar Vivadent) e em resina composta indireta SR Adoro (Ivoclar Vivadent) que foram cimentadas nas superfícies dentinárias. Os espécimes foram seccionados longitudinalmente em baixa velocidade e constante irrigação e polidos em politriz. Foi estabelecido um grupo controle positivo, no qual o cimento foi fotoativado sem a interposição de material restaurador indireto e um grupo controle negativo, no qual, após a cimentação do material restaurador indireto, a fotoativação foi suprimida, ocorrendo apenas a polimerização química do cimento. Todos os espécimes foram armazenados em água destilada a 37°C durante 7 dias e após esse período, foram submetidos ao teste de nanoendentação na linha de cimentação, com o auxílo do ultra-microdurômetro (Shimadzu Dynamic Ultra Micro Hardness Tester). O ciclo aplicado foi de 100mN. Foram realizadas cinco nanoendentações em cada espécime, cujas médias resultaram nos valores de cada superfície. Os resultados obtidos foram submetidos à Análise de Variância e Teste de Tukey (p<0,05). Podese concluir que o cimento RelyX ARC apresentou maiores valores de dureza do que o RelyX U200 e este foi mais dependente da fotoativação para alcançar uma polimerização adequada. A dureza dos cimentos resinosos avaliados foi influenciada negativamente pela interposição do material restaurador indireto e apenas os LEDs foram capazes de manter o mesmo grau de polimerização dos cimentos quando interposto um material restaurador indireto. / This study aimed to evaluate the hardness of a dual cure self-adhesive resin cement (RelyX U200) and a dual cure conventional resin cement (RelyX ARC) light curing units with different wavelengths (Elipar Freelight 2 LED, Bluephase LED, AccuCure 3000TM Laser) through nanoindentadion test. To obtain the specimens bovine incisors were used after prophylaxis. The tooth were sectioned at the limit amelocement for the separation of the coronal portion. After inclusion, the dentin surface of the specimens were exposed to standardize the substrate. To clinically simulate indirect restorations ceramic pieces were made (IPS e.max® Press/Ivoclar Vivadent) and indirect composite resin (SR Adoro/Ivoclar Vivadent) were cemented on dentin surfaces. The specimens were sectioned longitudinally at low speed with constant irrigation and polished. A positive control group was stablished, in which the cement was light cured without the interposition of indirect restorative material, and a negative control group, in which, after cementation of the indirect restorative material, the light curing was removed, occurring only the chemical polymerization of the cement. All specimens were stored in distilled water at 37°C for 7 days. Nanoindentadion hardness of the cement layer was measured under 100mN load (Shimadzu Dynamic Ultra Micro Hardness Tester). Five nanoindentations in each specimen were obtained, which resulted in the average values of each surface. Data were statistically analyzed using ANOVA and Tukey test (p<0,05). RelyX ARC pesented higher values of hardness than RelyX U200 and this was more dependent on the polymerization. The hardness of the evaluated resin cements was negatively influenced by the interposition of an indirect restorative material and only the LEDs were able to maintain the same degree of polymerization of the cement when an indirect restorative material was used.
8

Estudo da fotoativação de resina composta variando o comprimento de onda com laser de argônio por meio, dos testes de microdureza, variação térmica, grau de conversão e ablação / Study of the photo-activation of composite resin varyng the wavelenght eith argon laser, through microhardness, thermal varying, degree of conversion and ablation tests

Jacomassi, Denis Pablo 28 February 2007 (has links)
O objetivo deste trabalho foi investigar a variação do comprimento de onda na fotoativação de resina composta com Laser de argônio, por meio, dos testes de microdureza Vickres, variação de temperatura durante o processo de polimerização, grau de conversão e ablação. Os experimentos de microdureza foram conduzidos utilizando o aparelho MMT-3 Hardness Tester (Buehler Lake Bluff, IlIinois USA) equipado com diamante Vickers. Para medir a temperatura foi utilizado um termistor de alta precisão conectado a multímetro onde foram medidos valores de resistência em (Ohm). Para medir o grau de conversão utilizou-se o Espectrofotômetro FTIR BOMEM, modelo MB-102, na faixa espectral de 4000 a 400 cm-1. As amostras foram ablacionadas com o laser de Er:YAG pulsado, no regime de microssegundos, após a ablação os diâmetros e profundidades foram medidos com uma lupa com aumento de 40X e um relógio comparador. As amostras foram ablacionadas com Laser Libra-S (Coherent, Pala Alto, CA, EUA), no regime de femtossegundos, e medidos os diâmetros das microcavidades por meio de uma imagem gerada pelo microscópio eletrônico de varredura MEV (DSM 960, Zeiss, Jena, Germany). As imagens foram processadas em um programa matemático, onde foram calculados os diâmetros e com isso, calculada a intensidade threshold de ablação. As amostras foram confeccionadas em resina composta do tipo microhíbrida Z-250 (3M-Espe) fotoativada com o laser de argônio (Coherent, Innova 200-20, USA). Foram utilizados os comprimentos de ondas de 476.5,488.0, 501.7 e 514 nm, com tempos de exposições de 15, 40, 60, 300, 900 segundos. Considerando os testes realizados o melhor comprimento de onda para a fotoativação foi 488.0 nm, conforme pôde ser visto nos experimentos abordados nessa dissertação. / The aims this work to investigate the variation of the wavelength in the photoactivation of composite resin with argon, by means, them tests of microhardness Vikres, variation of temperature during the polymerization process, degree of conversion and ablation. The microhardness experiments were lead using device MMT-3 Microhardness Tester (Buehler Lake Bluff, Illinois the USA) equipped with Vickers diamond. To measure the temperature rise the multimeter was used a thermister of high precision hardwired where values of resistance in (Ohm) were measured. To the degree of conversion was used Spectrophotometer FTIR BOMEM, model MB-102, in the spectral band of 4000 to 400cm-1. The samples were ablateds with the Er:YAG Laser, in the regimen of microseconds, the ablation the diameter and depth has been after measured with a magnifying glass with increase of 40X and comparing a clock. The sample were ablated with Libra-S Laser (Coherent, High Palo, CA, U.S.A.), in the regiment femtosecond, and measured the diameter of the microcavities, by means, of a image generated for the electron microscope of sweepings SEM (DSM 960, Zeiss, Jena, Germany). The images were processed in a mathematical program, where the diameters were calculated and with this, calculated the threshold intensity of ablation. The samples had been confectioned in composed resin of the photo-activad Z-250 (3M-ESPE) microhibrid type with the argon laser (Coherent, Innova 200-20, the USA). The wavelength of 476.5, 488.0, 501.7 and 514.5 nm were used, with exposure times of 15, 40, 60, 300, 900 seconds. Considering the five carried through tests optimum wavelength for the photo-activation was 488.0 nm, o it could be in the boarded experiment in this dissertation.
9

Avaliação da alteração dimensional do cimento de ionômero de vidro modificado por resina em função da fotopolimerização e tempo de armazenagem / Influence of photocuring and storage time on the volumetric change of resin modified glass ionomer cement

Vieira, Ian Matos 26 April 2007 (has links)
Com o objetivo de se avaliar a relação entre o tempo de fotopolimerização e a alteração dimensional dos cimentos de ionômero de vidro modificados por resina foram analisadas três marcas comerciais deste material: Vitremer (3M/ESPE), Fuji II LC (GC International) e Vitro Fil LC (DFL). Foram confeccionados 60 espécimes no total, sendo 20 para cada marca comercial. Cada corpo-de-prova foi confeccionado em forma de disco, com dimensões de 5mm de diâmetro e 2mm de espessura, com auxílio de uma matriz de PTFE (politetrafluoretileno) vazada no centro, com as dimensões já especificadas. Após a manipulação e inserção do material dentro da cavidade da matriz, e cobertura desta com lâmina de vidro de cada lado, o conjunto foi colocado, durante 15 minutos, dentro de uma caixa de papelão hermeticamente fechada, o que impediu a entrada de luz em seu interior. Dos 20 espécimes confeccionados de cada marca comercial, quatro grupos (n=5) foram formados, variando-se a forma de polimerização com o aparelho de luz halógena Demetron (Dabi-Atlante). O grupo 1 foi fotopolimerizado por 20s, o grupo 2 por 40s, o grupo 3 por 60s, e o grupo 4 não sofreu o processo de fotopolimerização (grupo controle). Cada espécime foi armazenado em um frasco plástico, com 10ml de água destilada, em uma estufa, com temperatura interna de 37ºC. As alterações dimensionais das amostras foram avaliadas nos intervalos de 24 horas, 7 dias e 30 dias de armazenamento. Para o cálculo das alterações volumétricas foi utilizada uma equação física, baseada no princípio hidrostático de Arquimedes, na qual eram obtidas as massas dos espécimes dentro da água e fora dela. Para isso foi utilizada uma balança analítica (AT 261 Delta Range/Mettler Toledo) com aparato de especificação de densidade. As médias dos resultados, em porcentagem da alteração volumétrica, foram submetidas à análise de variância a três critérios seguido pelo teste de Tukey para a averiguação da significância entre os grupos (a=0,05). Os resultados demonstraram que todos os materiais se expandiram após 30 dias. O Vitremer sofreu o menor grau de expansão quando não fotopolimerizado, no entanto, o tempo de fotopolimerização não influenciou o grau de alteração volumétrica, com exceção do Fuji II LC, cuja expansão foi maior após 60s de fotoativação. O Vitro Fil LC teve o volume diminuído entre 7 e 30 dias. Concluiu-se que o tempo de fotopolimerização pode afetar a alteração de volume do cimento de ionômero de vidro modificado por resina, porém não é o único fator relacionado a isto. / This study evaluated the effect of photoativation and storage on the hygroscopic expansion of resin modified glass ionomers (Vitremer-3M/ESPE, Fuji II LC-GC Int., Vitro Fil LC-DFL). . Twenty specimens, 5 +/- 1mm in diameter and 2mm in thickness, were made of each material in a mold of PTFE, . The RMGIC were manipulated according to the manufacturers instructions and inserted into a mold under two glass microscope slides and kept in a darkness box for 15 minutes. Then, the samples were distributed into four groups (n=5): light-cured for 20s, light-cured for 40s, light-cured for 60s and not light-cured (control group). Each sample was storage in distilled water at 37ºC. The measurements of volumetric changes were made in three different times of storage: 24 hours, 7 days and 30 days. Volumetric changes were determined using Archimedes principle, which change in buoyancy of a material in a fluid depends on the volume changes of the material. Measurements were made by an analytic balance with density apparatus (AT 261 Delta Range/Mettler Toledo). Means and standard deviations values were analyzed by three-way analysis of variance and Tukey\'s test to compare significance between the groups (a=0,05). All materials underwent volumetric expansion after 30 days. Vitremer showed the less expansion when no light-cured. The time of light-cure did not influence the volumetric change, except for Fuji II LC, that showed great expansion when activated for 60s. Vitro Fil LC showed some degree of shrinkage after 7 days. This study concluded that photocuring can influence the volumetric change of resin modified glass ionomer cement.
10

Estudo in vitro do efeito de unidades fotoativadoras com diferentes comprimentos de onda na dureza (por meio de micro e ultramicroendentação) e módulo de elasticidade de uma resina composta nanohíbrida / Effect of light sources with different wavelengths in micro and ultramicrohardness and elastic modulus of a nanohybrid composite resin. An in vitro study

Araujo, Jesuina Lamartine Nogueira 04 June 2013 (has links)
Este trabalho avaliou in vitro a dureza e módulo de elasticidade de uma resina composta nanohíbrida (Tetric N-Ceram/Ivoclair-Vivadent) com diferentes cores, fotoativada por duas unidades com diferentes comprimentos de onda em 3 espessuras (1, 2 e 3mm) comparadas à partir da superfície irradiada (0mm). Os espécimes foram divididos em grupos (n=5): microdureza Knoop-KHN, ultramicrodureza-DUH e módulo de elasticidade-ME, cor (A2 e Bleach-M(BM), fotoativador LEDazul (Elipar Freeligth2/3M(750mW/25s/430-480nm(FL) e LEDazul/violeta Bluephase/Ivoclar/Vivadent (1200mW/cm²/15s/380-515nm(B15) e 30s(B30). Os espécimes foram armazenados por 24h/37ºC. Os ensaios de KHN foram realizados no HMV-2000/Shimadzu, com carga de 25gf/40s, e de DUH e ME no DUH 211S/Shimadzu com força de 10mN e tempo de espera de 0s. Foram realizadas 5 endentações na superfície irradiada (0mm) e na base das amostras (1, 2 e 3mm). A análise estatística foi realizada por ANOVA, Tukey e correlação de Pearson (p<0,01%). O teste de Pearson mostrou haver correlação direta entre a KHN e a DUH. A fonte FL promoveu maiores valores de KHN e de DUH para as duas resinas testadas; enquanto que a fonte B15, promoveu o maior valor de ME. Quanto às espessuras, 0 e 1mm apresentaram maiores valores de KHN e de DUH, e menores de ME que as espessuras de 2 e 3mm. A cor A2 apresentou maior valor de KHN e DUH e menor ME que a cor Bleach-M. Assim, de acordo com a metodologia proposta e os resultados apresentados pode-se concluir que apesar de a luz LEDazul/violeta propor uma maior eficácia na polimerização de resinas de cor clara, no tocante às propriedades avaliadas isso não foi verificado. / This study evaluated in vitro the hardness (micro and ultramicro) and elastic modulus of a nanohybrid composite resin (Tetric N-Ceram/Ivoclar-Vivadent) with different colors, light sources and thickness. The specimens were divided into groups (n=5): KHN-Knoop microhardness, DUH-nanohardness and ME-elastic modulus; colors: A2 and Bleach-M (BM); light sources: LEDblue Elipar Free light 2/3M-ESPE (750mW/cm²/ 25s/430-480nm- (FL)), LEDblue/violet Bluephase/Ivoclar-Vivadent (1.200mw/cm²/15s/380-515nm) (B15) and 30s (B30); thickness: 1mm, 2mm and 3mm, compared to the irradiated surface (0mm). Specimens were stored dry for 24hours at 37ºC after photo curing. Assays were performed at KHN in HMV-2000/ Shimadzu with load of 25gf at 40s and DUH/ME in DUH 211S/Shimadzu with force of 10mN and no hold time (0s). 5 indentations of each test were made in the surfaces opposites to the photo curing. A statistical analysis was performed by ANOVA, Tukey and Pearson correlation (p<0.01%). Pearsons Test showed a direct correlation between KHN and DUH. Comparison between KHN and ME in the studied resins indicated that the light source FL promoted higher values of KHN and DUH to both resins tested, whereas the B15 light source promoted the higher ME value. Regarding thickness 0mm and 1mm showed higher KHN and DUH and lower ME than 2 and 3mm thickness. A2 color showed higher KHN and DUH and lower ME than BM. Thus, according to the proposed methods and the presented results, the LEDblue/violet was not better for curing the light color of the nanohybrid resin, than LEDblue.

Page generated in 0.4591 seconds