• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 181
  • 11
  • 6
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 1
  • 1
  • 1
  • Tagged with
  • 208
  • 208
  • 195
  • 175
  • 156
  • 75
  • 69
  • 68
  • 64
  • 54
  • 48
  • 40
  • 39
  • 35
  • 35
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

EFEITO DA INCLUSÃO DE PARTÍCULAS DE CARGA NA RADIOPACIDADE E EM PROPRIEDADES DE SISTEMAS ADESIVOS EXPERIMENTAIS / Effects of of filler addition to experimental adhesives on radiopacity and properties

Martins, Gislaine Cristine 13 November 2012 (has links)
Made available in DSpace on 2017-07-24T19:22:25Z (GMT). No. of bitstreams: 1 Gislaine Cristine Martins.pdf: 4074240 bytes, checksum: e09201e7bd1d75eac883e17325cc0c46 (MD5) Previous issue date: 2012-11-13 / The aim of this study was to evaluate the radiopacity, ultimate tensile strength (UTS), microhardness (KHN), degree of conversion (DC), water sorption (WS), solubility (SO), microtensile bond strength (μTBS) and of experimental dental adhesives with increased addition of barium-borosilicate zirconia nanoparticles or glass microparticles. Methods: Ten experimental adhesive systems with different concentrations of zirconia nanoparticles [0(EX0), 15(EX15), 25(EX25), 35(EX35) and 50%(EX50) and barium-borosilicate oxide microparticles [0(R0), 30(R30), 40(R40), 50(R50) e 60%(R60)] were formulated based on the adhesive system Ambar (FGM). The adhesive Adper Single BondTM 2 (SB, 3M ESPE) was used as commercial reference. For the radiopacity (n=5), KHN (n=5), WS (n=10) and SO (n=10) tests, adhesive specimens were constructed using a stainless steel mold (5.0 mm in diameter and 1.0 mm in deep), while for UTS (n=5), a hourglass shape metallic matrix (10 mm long, 2 mm wide, and 1 mm deep with cross-sectional area of 0.8 mm2) was employed.The FTIR spectra of uncured and cured specimens of adhesives were used to determine the DC of the materials. For μTBS, adhesives were applied to flat dentin surfaces of third molars (n=7). Resin composite buildups were constructed and sectioned to obtain resin-dentin bonded sticks to tested immediately (IM) or after 6 months (6M) of water storage. Data were submitted to a one-way ANOVA and Tukey´s test (α=0.05). Results: All experimental bonding adhesives showed radiopacity similar to enamel. Only R60 showed higher UTS than the other materials. The experimental adhesives showed higher KHN values when compared to the commercial SB. In general, the DC of the experimental solutions was not affected by filler addition and was statistically higher than SB. Although filler addition did not affect WS, it generally reduced the SO. Most of the experimental adhesives showed lower WS and SO than SB. Conclusions: Both the addition of nanoparticles as microparticles were able to confer radiopacity to adhesives experimental, and adding load influence on the properties tested. In general, it can be said that the best performance was for the addition of microparticles in a concentration of 30%. / Objetivo: Este estudo objetivou avaliar a radiopacidade, resistência máxima à tração,(RMT), microdureza (KHN), grau de conversão (GC), sorção de água (SA),solubilidade (SO), resistência de união (μTBS) de sistemas adesivos experimentais pela adição de nanopartículas de zircônia ou micropartículas de vidro de bárioborosilicato. Material e métodos: Dez sistemas adesivos experimentais com diferentes concentrações de nanopartículas de zircônia [0(EX0), 15(EX15), 25(EX25), 35(EX35) e 50%(EX50) ou com micropartículas de óxido de bário-borosilicato [0(R0), 30(R30), 40(R40), 50(R50) e 60%(R60)] foram formulados tendo como base o sistema adesivo Ambar (FGM). O sistema adesivo Adper Single BondTM 2 (SB, 3M ESPE) foi utilizado como referência comercial. Foram confeccionados espécimes de adesivo para os testes de radiopacidade (n=5), KHN (n=5), SA (n=10) e SO (n=10) utilizando matriz metálica com 5,0 mm de diâmetro e 1,0 mm de profundidade e, para a RMT (n=5) uma matriz metálica com 10 mm de comprimento, 2 mm de largura, 1 mm de profundidade e, área de sessão transversal de 0,8 mm2. Os espectros FTIR foram obtidos de espécimes não polimerizados e polimerizados dos adesivos para determinar o GC dos materiais. Para μTBS, aplicou-se os adesivos na superfície de dentina de dentes molares humanos (n=7). Os dentes foram reconstruídos com resina composta e cortados para obtenção de espécimes em forma de palitos que foram testados imediatamente (IM) ou após 6 meses de armazenamento em água (6M). Os dados foram submetidos a ANOVA e pós-teste de Tukey´s (α=0,05). Resultados:Todos os sistemas adesivos experimentais mostraram radiopacidade semelhante a do esmalte dental. Apenas o R60 mostrou valores de RMT mais elevado que os outros materiais. Os sistemas adesivos experimentais apresentaram valores mais altos de dureza Knoop quando comparado ao SB. Em geral, o GC dos adesivos experimentais não foi afetado pela adição de partículas e, significantemente superior ao SB. A maioria dos adesivos experimentais mostraram menor SA e SO que o SB.Conclusões: Tanto a adição de nanopartículas quanto de micropartículas foi capaz de conferir radiopacidade aos adesivos experimentais e, a adição de carga influenciou nas propriedades testadas. De modo geral, pode-se dizer que o melhor desempenho foi para a adição de micropartículas na concentração de 30%.
122

Efeito da técnica úmida simplificada de adesão com etanol na cimentação intraradicular de pinos de fibra / Push-out bond strength and SEM evaluation of new bonding approach into the root canal

Carvalho, Carlos Augusto Ramos de 28 June 2011 (has links)
Este estudo avaliou a resistência ao deslocamento vertical push-out de pinos de fibra de vidro cimentados à dentina intra-radicular utilizando uma resina fluida padrão como agente cimentante em combinação com um adesivo dentinário experimental e um adesivo disponível comercialmente. 20 pré-molares unirradiculares humanos foram previamente extraídos e tratados endodonticamente. Os espécimes foram divididos em quatro estratégias de união a dentina: Grupo 1 com adesivo experimental com etanol na proporção em volume 1:1 (resina/etanol) e Grupo 2 com adesivo experimental com etanol na proporção em volume 1:2(resina/etanol); adesivos experimentais aplicados de acordo com a técnica úmida de adesão simplificada com etanol, Grupo 3: One-Step Plus aplicado de acordo com a técnica úmida de adesão simplificada com etanol; Grupo 4: One-Step Plus aplicado seguindo as instruções do fabricante. Os espécimes foram seccionados em fatias de 1 mm de espessura e apos o teste push-out foi realizado. Espécimes representativos foram selecionados para exame ultra-estrutural. Não houve diferença estatística na resistência ao deslocamento push-out entre as estratégias testadas de adesão (p> 0,05). O padrão predominante de fratura foi entre os pinos de fibra e o agente cimentante. A partir deste estudo devemos considerar como promissora a técnica com etanol utilizada na cimentação de pinos no canal radicular devido aos possíveis benefícios das resinas altamente hidrófobas. Mais estudos são necessários para validar o uso da técnica úmida de adesão simplificada com etanol quando cimentados pinos de fibra. / This study evaluated the push-out bond strength of glass fiber posts adhesively bonded to intraradicular dentin using a standard unfilled resin as luting agent in combination with an experimental and a commercially available adhesive. Twenty extracted single-rooted human teeth were endodontically treated. Specimens were assigned to 4 dentin bonding strategies: Group 1 (co-monomers to ethanol on ratio 1:1) and Group 2 (co-monomers to ethanol on ratio 1:2): Experimental adhesives applied in accordance with the simplified ethanol-wet bonding technique; Group 3: One-Step Plus (OSP) applied in accordance with the simplified ethanol-wet bonding technique; Group 4: OSP applied following manufacturers instructions. Bonded specimens were sectioned in 1-mm-thick slices and the push-out test was performed. Representative specimens were selected for ultrastructural examination. No statistical differences in push-out bond strength were found among the tested bonding strategies (p>0.05). The major failure pattern was between the post and the luting cement. From this study the ethanol technique should be considered as a promising approach in the luting of fiber posts into the root canal due to the possible benefits of highly hydrophobic resins. Further studies are needed to validate the use of the ethanol-wet bonding technique when luting a fiber post.
123

"Influência das ciclagens térmica, mecânica e de pH na resistência de união de sistemas adesivos à dentina de dentes decíduos" / Thermal, mechanical load and pH cycling influence on adhesive systems bond strength to primary dentin.

Rocha, Rachel de Oliveira 16 December 2004 (has links)
Nesta pesquisa foi realizada a avaliação da influência das ciclagens térmica, mecânica e de pH na resistência de união de sistemas adesivos à dentina de dentes decíduos. Para tal, cavidades oclusais foram preparadas em 80 molares decíduos e restauradas com os sistemas adesivos Single Bond e Clearfil SE Bond e resina composta Z100. Os dentes restaurados com cada um dos sistemas adesivos foram divididos em oito grupos (n= 5), de acordo com as condições de tratamento: ciclagem térmica (2000 ciclos, 5°C e 55°C), ciclagem de pH (10 ciclos, 8 horas de imersão em solução desmineralizadora e 16 em solução remineralizadora), ciclagem mecânica (100.000 ciclos, 8 kg), térmica/pH, térmica/mecânica, pH/mecânica e térmica/pH/mecânica, além do grupo controle. Os dentes foram seccionados perpendicularmente à interface de união e foram obtidos espécimes com área de superfície aderida com cerca de 0,8 mm 2 . Os espécimes foram submetidos ao teste de microtração e à análise do padrão de fratura em microscopia eletrônica de varredura. Os valores obtidos, expressos em MPa, foram submetidos à Análise de Variância (p < 0,05). Não foram encontradas diferenças estatísticas significantes na comparação entre os sistemas adesivos avaliados nem para os grupos submetidos à aplicação dos estresses térmico, mecânico e térmico/pH. Os demais grupos apresentaram valores de resistência de união inferiores àqueles obtidos pelo grupo controle (p < 0,05) Fraturas do tipo adesiva/mista foram as mais prevalentes (95,9%). A resistência de união dos sistemas adesivos avaliados é negativamente influenciada pela aplicação combinada das tensões com naturezas distintas. / The influence of thermal, mechanical load and pH cycling on adhesive systems bond strength to primary dentin was evaluated. Occlusal cavities in 80 primary molars were prepared with diamond bur and restored with Single Bond and Clearfil SE Bond adhesive systems and Z100 composite. Teeth restored with each adhesive system were shared into eight groups according treatment condition: thermal cycling (2000 cycle, 5°C and 55°C), pH cycling (10 cycles, demineralization solution immersion to 8 hours and 16 hours in remineralization solution), mechanical load cycling (100.000 cycles, 8kg), thermal/pH, thermal/mechanical load, pH/mechanical load and thermal/pH/mechanical load, besides control groups. The teeth were transversally sectioned in two axis rendering 0,8mm 2 stick shaped specimen. Sticks were then submitted to microtensile bond testing with a crosshead speed of 1mm/min. Fracture analysis was performed by scanning electron microscopy. Bond strength means expressed in MPa were submitted to two-wav ANOVA (p<0.05). No statistically significant differences were found between the adhesive systems nor to thermal, mechanical load and thermal/pH stresses groups. Lower bond strength values were found to other groups compared to control (p<0.05). Adhesive/mixed failures were prevalent (95.9%). Bond strengths of evaluated adhesive systems were negatively influenced by distinct tension application.
124

Efeito de inibidores proteolíticos na adesão de dentina desmineralizada por cárie ou erosão / Effect of proteolytic inhibitors in carious and eroded dentin adhesion

Giacomini, Marina Ciccone 09 February 2015 (has links)
A longevidade da interação estabelecida entre a união do material restaurador e substrato tem sido o foco principal da Odontologia Adesiva. Se por um lado, a dentina é alterada por desafios como a erosão e a cárie dentária, por outro lado, tecnologias que atendam às condições distintas do substrato e que possibilitem união química tem sido desenvolvidas. O objetivo desde trabalho foi avaliar o desempenho de um sistema adesivo restaurador universal (modo convencional) na resistência de união (RU) à dentina em diferentes condições (artificialmente erodida ou cariada) e pré-tratadas com inibidores proteolíticos. Noventa molares hígidos foram selecionados e preparados, obtendo-se superfícies planas que foram tratadas com lixa 600 por 1 minuto. Os espécimes foram aleatoriamente divididos em três grupos iniciais, de acordo com o substrato: N- sem simulação de desafio ácido (mantidos em saliva artificial); ERO- simulação de erosão (3x5min/5dias com suco de laranja) e CA- simulação de cárie artificial (6h desmineralizante+ 18hremineralizante/ 5 dias + 48 remineralizante). Em seguida, cada um desses grupos foi redividido em três subgrupos, de acordo com o pré-tratamento da dentina: Atratado com água; CHX- tratado com clorexidina a 2%e E-64- tratado com o inibidor E-64 a 5 &#x3BC;M. No total, formaram-se, 9 grupos (n=10): N-A, N-CHX, N-E-64, ERO-A, ERO-CHX, ERO-E-64, CA-A, CA-CHX, CA-E-64. Todos os espécimes foram restaurados com adesivo Adper Single Bond Universal® e com resina composta Filtek Z250. Os dentes foram cortados para a obtenção dos palitos (área de 0,64mm2 aproximadamente), que foram submetidos ao ensaio de microtração em máquina de teste a 0,5mm/min em 7 dias e 6 meses. O modo de fratura foi classificado de acordo com a análise das interfaces com microscopia ótica 40X. Os dados foram submetidos ao teste de normalidade e homogeneidade e analisados por ANOVA a três critérios e teste de Tukey (p<0,05). Os resultados demonstraram que houve interação entre o substrato x tratamento (p=0,0011) e substrato x tempo (p=0,0003). A dentina alterada por erosão e cárie artificialmente contribuíram negativamente na RU do sistema adesivo. O uso de clorexidina afetou negativamente a RU em todas as condições testadas. O E-64 mostrou-se efetiva em manter a estabilidade da união aos 6 meses para os substratos alterados. O sistema adesivo universal apresenta-se promissor para ser utilizado na dentina alterada, mantendo a resistência de união ao longo do tempo. O uso de E-64 não comprometeu a união à dentina, ao contrário do impacto no uso da solução de clorexidina. / The longevity of the interaction established between restorative material and substrate has been the main focus of Adhesive Dentistry. Dentin is altered through challenges as dental erosion and caries and, on the other hand, technologies that attend for particular conditions of the substrate and favors for the chemical bonding has been developed. The aim of this study was to evaluate the performance of a universal adhesive system (etch-and-rinse mode) on bonding strength (BS) to dentin in different conditions (artificial caries or erosion) and pretreated with proteolytic inhibitors. Ninety molars were selected and prepared, obtaining flat surfaces treated with 600 sandspaper for 1 minute. The specimens were randomly divided into three groups according to the substrate: N- with no challenges (stored in artificial saliva), ERO-artificial erosion simulation (3x5min/5days with orange juice) and CA- artificial caries simulation (6h demineralizing+ 18h-remineralizing/ 5 days + 48 remineralizing). Then, each of these groups was redivided into three subgroups according to the pretreatment of dentin: A- treated with water; CHX-treated with 2% chlorhexidine and E-64- treated with 5 &#x3BC;M E-64 inhibitor. Therefore, they constituted 9 groups (n = 10): N-A, N-CHX, N-E-64, ERO-A, ERO-CHX, ERO-E-64, CA-A, CACHX, CA-E-64. All specimens were restored with Adper Single Bond ® Universal and composite resin Filtek Z250. The teeth were cut to obtain sticks (area of approximately 0.64 mm2), which were subjected to the microtensile bond test in the testing machine at 0.5 mm/min after 7 days and 6 months. The failure mode was classified according to the analysis of interfaces by optical microscopy 40X. Data was tested to verify normal distribution and homogeneity to be analyzed with three-way ANOVA and Tukey tests (p <0.05). Data revealed interaction between substrate x treatment (p=0.0011) and between substrate x time (p=0.0003). Dentin affected by artificial erosion and caries negatively contributed to the BS. The use of chlorhexidine negatively affected the RU for all tested conditions. E-64 showed to be effective to maintain the bonding stability to affected dentin for 6 months. The universal bonding system seems to be promissory to be employed to affected dentin, maintaining the BS overtime. The use of E-64 did not affect the bonding to dentin, controversial to the use of chlorhexidine.
125

Estudo in vitro da influência da dureza e módulo de elasticidade de sistemas adesivos na resistência de união à dentina humana / In vitro study of influence of hardness and elasticity module of adhesive sistems in bond strenght to human dentin

Bengtson, Camilla Regina Galvão 01 February 2011 (has links)
O objetivo deste trabalho foi avaliar a dureza e o módulo de elasticidade da região de adesão quando utilizados diferentes sistemas adesivos e uma resina composta imediatamente após o procedimento adesivo e após 6 meses de armazenamento, correlacionando esses valores com a resistência adesiva à dentina humana. Para isso foram medidos a dureza e o módulo de elasticidade da resina composta junto à área de união, da camada de adesivo, da camada híbrida, e da dentina adjacente utilizando testes de nanoendentação. Foram utilizados 40 molares humanos hígidos (n=10). Os dentes foram preparados de modo a obterem-se superfícies planas em dentina, sobre as quais os sistemas adesivos foram aplicados seguindo as instruções dos fabricantes. Foram utilizados quatro sistemas adesivos de diferentes formas de aplicação (Adper Scotchbond Multiuso, Adper Single Bond 2, Adper SE Plus e Clearfil SE Bond). Sobre essas superfícies foram inseridos incrementos de resina composta perfazendo 5 mm de altura. Após 24h de armazenamento em água destilada à 37ºC. Os dentes restaurados foram seccionados para obterem-se corpos-de-prova com área aderida de 1mm2. Dos corpos de prova viáveis, 2 palitos centrais de cada dente foram selecionados para análise da nanodureza e do módulo de elasticidade da interface adesiva. Os demais tiveram a resistência de união testada através do teste de microtração, sendo metade desses corpos de prova armazenados durante 6 meses em água à 37ºC. Foi aplicado o teste estatístico ANOVA para dois fatores para todas as variáveis do estudo. Para o fator tempo foi detectada diferença estatística entre os grupos para a resistência adesiva (p=0,042), para o módulo de elasticidade do adesivo (p=0,000) e nanodureza do adesivo (p=0,000), sendo os valores mais baixos observados após 6 meses de armazenamento. Para o fator adesivo, todos os grupos apresentaram diferenças estatísticas (p=0,000), exceto para a variável nanodureza da camada híbrida (p=0,255). O sistema adesivo Clearfil SE Bond apresentou os melhores valores para resistência adesiva e módulo de elasticidade da camada híbrida, juntamente com o sistema Scothbond Multiuso. Os piores desempenhos foram demonstrados pelo sistema adesivo Adper SE Plus. Para a interação, apenas a variável nanodureza do adesivo apontou diferença entre os grupos (p=0,028). O teste de correlação de Pearson detectou correlação significante para as variáveis de módulo de elasticidade, sendo negativa para o módulo de elasticidade do adesivo e positiva para o módulo de elasticidade da camada híbrida. A metodologia e os resultados apresentados permitem-nos concluir que as propriedades mecânicas estudadas (resistência adesiva, módulo de elasticidade do sistema adesivo e da camada híbrida, nanodureza do sistema adesivo e da camada híbrida) podem variar dependendo do sistema adesivo utilizado e do tempo de armazenamento após o procedimento adesivo ter sido realizado. Além disso, quanto maior o módulo de elasticidade da camada híbrida apresentado por um sistema adesivo maior será sua resistência adesiva e menor será o módulo de elasticidade apresentado pela camada de adesivo. / The aim of this study is to evaluate hardness and elasticity module of adhesive region of adhesive systems of different formulations immediately and 6 moths after the adhesive procedures. Those values will be compared to microtensile bond strength to human dentin. The hardness and elasticity module of composite resin next to adhesion region, adhesive layer, hybrid layer and dentin were evaluated. Forty sound human molars were used and prepared in order to obtain flat dentin surfaces in which the adhesive systems were applied following manufactures instructions (n=10). The groups were divided according the four adhesive systems: Adper Scotchbond Multipurpose, Adper Single Bond 2, Adper SE Plus and Clearfil SE Bond. Resin blocks of 5mm were constructed in those surfaces. After 24h of storage in distilled water at 37°C restored teeth were sectioned in order to obtain specimen with a bonded area of around 1mm2. Two specimen of each tooth were submitted to nanohardness and elasticity module test of adhesive interface. Half of the specimen were immediately submitted to the test with a crosshead speed of 0,5mm/min until fracture, the other specimen were stored for additional 6 month in 37ºC water prior to the test. The values resulting of all variables of the study were compared using ANOVA two-way. For the time factor, it was detected statiscal difference between groups in microtensile bond strength values (p=0,042), adhesive elastic modulus (p=0,000) and adhesive nanohardnes (p=0,000), the lowest values were observed in 6 months of storage. For adhesive factor, all groups presented statistical difference (p=0,000), except hybrid layer nanohardness (p=0,255). Clearfil SE bond and Scothbond systems presented the best values of bond strength and hybrid layer elastic modulus. The worse performance was demonstrated by Adper SE Plus adhesive system. For the interaction, only the adhesive nanohardness presents difference between groups (p=0,028). The Pearson correlation test detected positive correlation with microtensile bond strength tests and hybrid layer elastic modulus and negative correlation with bond strength and adhesive elastic modulus. The methodology and the results allow us to conclude that the studied mechanical properties (bond strength, modulus of elasticity of the adhesive and hybrid layer, nanohardness adhesive system and the hybrid layer) may vary depending on the adhesive system and time storage after the bonding procedures have been performed. Moreover, when an adhesive system presents a high elastic modulus of hybrid layer, it will present a high bond strength and low elastic modulus of adhesive layer.
126

Efeito de material cimentante e do tempo na resistência adesiva de pinos de fibra de vidro

Campos, Leonardo Maciel [UNESP] 11 September 2000 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:05Z (GMT). No. of bitstreams: 0 Previous issue date: 2000-09-11Bitstream added on 2014-06-13T21:02:09Z : No. of bitstreams: 1 campos_lm_dr_arafo.pdf: 780385 bytes, checksum: fa6ceb171b4f9b18b447135b81ada411 (MD5) / O objetivo desse estudo foi avaliar in vitro a resistência à tração de pinos de fibra de vidro cimentados em raízes de dentes bovinos com quatro agentes cimentantes em dois períodos de tempo de armazenamento em saliva artificial: com 48 horas e após 240 dias. Para tal, foram utilizadas 80 raízes de dentes bovinos que, após tratamento endodôntico, foram divididas em 8 grupos com 10 raízes para cada grupo. Para a fixação dos pinos foram utilizados 4 diferentes agentes cimentantes sendo que, os quatro primeiros grupos foram armazenados em saliva artificial por 48 horas antes do teste de tração; a saber: Grupo I – cimento resinoso dual (Rely X e Adper Single Bond-3M/ESPE), Grupo II – cimento de ionômero de vidro (Bioglass “C”- BIODINÂMICA), Grupo III – cimento de fosfato de zinco (SS WHITE), Grupo IV – cimento resinoso quimicamente ativado (CB Cement e One-Step/ BISCO). Os outros 4 Grupos (V, VI, VII e VIII) receberam os mesmos agentes cimentantes citados acima e na mesma seqüência porém, armazenados em saliva artificial por 240 dias antes da realização do teste de resistência à tração em uma Máquina de Ensaio Universal (VERSAT 500) à velocidade de deslocamento de 1,0 mm/min. Os dados foram catalogados e submetidos à análise estatística mediante os testes Análise de Variância, Tukey e t-student. Os resultados mostraram após 48 horas de armazenamento, o comportamento dos Grupos em estudo e podem assim ser representados: G IV > G III > G I > G II, no entanto, após 240 dias: G VIII = G VII  G VI  G V; concluindo que: a resistência à tração de pinos de fibra de vidro; cimentada em raízes bovina, foi influenciada com o tempo, pois, quanto maior o tempo de envelhecimento, menor é o valor da resistência, com exceção do cimento de ionômero de vidro. / The purpose of the present investigation was to assess the in vitro tensile bond strength resistence of fiberglass posts retained with different cementing agents in bovine teeth at different time points, upon incubation with artificial saliva. To that end, eighty roots harvested from bovine teeth received endodontic treatment and were split into 8 groups (10 roots per group). The fiberglass posts were retained with four different cementing agents, and the first groups were incubated with artificial saliva 48 hours before the tensile test. The groups were distributed as follows: Group I – dual resin cement (Rely X e Adper Single Bond-3M/ESPE), Group II – glass ionomer cement (Bioglass “C”- BIODINÂMICA), Group III – zinc phosphate cement (SS WHITE) and Group IV – chemically activated resin cement (C&B Cement e One -Step/BISCO). The remaining four groups (V, VI, VII and VIII) were accordingly treated with the same cementing agents and conditions, except for the fact that they were incubated with artificial saliva for 240 days before being subjected to the tensile test using a Universal Testing Machine (VERSAT 500) at 1.0 mm/min. The data generated were collected and subjected to statistical analysis through ANOVA, Tukey post-hoc and Student-t tests. After 48 hours of incubation in artificial saliva, the outcome can be presented as follows regarding the traction test: G IV > G III > G I > G II. On the other hand, after 240 days of incubation the outcome was G VIII = G VII  G VI  G V. The findings allow us to state that the tensile bond strength of fiberglass posts cemented in bovine teeth roots was affected by the variable time because the longer the aging the lower is the resistance, except the glass ionomer cement.
127

Efeito do tempo de condicionamento na degradação da união resina-dentina decídua /

Sanabe, Mariane Emi. January 2005 (has links)
Orientador: Josimeri Hebling / Banca: Ricardo Marins de Carvalho / Banca: Luís Geraldo Vaz / Resumo: O presente estudo teve como objetivo investigar o efeito da redução do tempo de condicionamento da dentina decídua na resistência de união imediata de um sistema convencional e um autocondicionante, e na degradação da união resina-dentina após 6 meses de armazenagem em água. Foram utilizados quarenta e oito molares decíduos hígidos foram aleatoriamente divididos em 4 grupos (n=12) de acordo com o sistema adesivo (Adper Single Bond e Clearfil SE Bond) e o tempo de condicionamento da dentina (como recomendado pelo fabricante e metade desse tempo). Desta forma, o sistema Single Bond foi aplicado sobre a dentina condicionada com ácido fosfórico a 35% por 15 ou 7 segundos, enquanto que o sistema Clearfil SE Bond foi aplicado à dentina condicionada com SE Primer por 20 ou 10 segundos. Em seguida, coroas em resina composta foram reconstruídas incrementalmente e os dentes foram mantidos hidratados em estufa à 37o C por 24 horas. Dez dentes de cada grupo foram utilizados para o ensaio mecânico de microtração. Os demais foram preparados para análise da interface adesiva em MEV. Espécimes em forma de pilar de secção transversal quadrangular (0,49 mm2) foram obtidos e divididos de acordo com a condição de armazenagem, 24 horas em água (controle), 6 meses em água e 6 meses em óleo. Os espécimes foram tracionados a velocidade de 0,5 mm/min em máquina de ensaios mecânicos e as fraturas classificadas em adesiva, coesiva em dentina, coesiva em resina ou mista. Os dados foram analisados estatisticamente pela análise de variância e testes complementares de comparação múltipla, considerando-se o nível de significância de 5%. Após 24 horas de armazenagem, os sistemas adesivos apresentaram valores de resistência de união comparáveis estatisticamente, não influenciados pela redução do tempo de condicionamento ácido... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: To evaluate the effect of reducing the acid etching of primary dentin on the immediate bond strength of a conventional and a self-etching primer system, and on the degradation of the resin-dentin bonds after 6 months aging. Forty-eight sound primary molars were randomly divided into 4 groups of investigation (n=12) according to the adhesive system (Adper Single Bond and Clearfil SE Bond) and the period of acid etching (as recommended by the manufacturers and half of this time). Single Bond was applied to dentin after 35% phosphoric acid etching for 15 seconds or 7 seconds, whereas Clearfil SE Bond was applied to dentin after the application of SE Primer for 20 seconds or 10 seconds. Following the adhesive systems, composite resin crowns were incrementally built-up and the teeth were stored in water at 37o C for 24 hours. Specimens with a cross-sectional area of 0,49 mm2 were produced from each one of the teeth (10 teeth per group) and further divided according to the storage condition, 24 hours in water, 6 months in water and 6 months in mineral oil, when they were tested under tension until failure in a machine operating at a cross-head speed of 0.5 mm/min. After the microtensile test, the failures were classified as adhesive, cohesive in dentin, cohesive in resin or mixed. The two remaining teeth per group were prepared to SEM evaluation of the interfaces. Two-way analysis of variance and multiple comparison testes were applied at a significance level of 5%. When bond strength was evaluated after 24 hours storage in water there was no significant difference between the adhesive systems, irrespective of the periods of acid etching. For Single Bond, water storage for 6 months in water significantly reduced bond strength, especially when the dentin was phosphoric acid conditioned for 15 seconds (36.7% reduction). For Clearfil SE Bond... (Complete abstract, click electronic address below). / Mestre
128

Inter-relação do comprimento dos prolongamentos resinosos (tags) e da espessura da camada híbrida de adesão, com a resistência de união de sistemas adesivos ao tecido dentinário /

Rahal, Vanessa. January 2009 (has links)
Orientador: Renato Herman Sundfeld / Banca: André Luiz Fraga Briso / Banca: Alma Blásida Concepcíon Elizaur Benitez Catirse / Resumo: O objetivo deste estudo foi analisar a correlação da espessura da camada híbrida de adesão e do comprimento dos prolongamentos resinosos (tags), com a resistência de união em tecido dentinário hígido, de um sistema adesivo convencional e de outro autocondicionante. Após a realização "in vivo" dos procedimentos restauradores, os dentes foram extraídos e seccionados no sentido mésio/distal. Em uma secção dental foi realizada a análise microscópica dos prolongamentos resinosos e da camada híbrida de adesão. Para tanto, os espécimes foram descalcificados, incluídos em parafina e cortados a uma espessura de 6 μm. Os cortes foram corados pelo método Brown e Brenn, para posterior análise e mensuração em microscópio óptico comum Axiophot Zeiss em 1000× (Carl Zeiss Company - DSM-940 A, Oberkochen, Baden- Württemberg, Germany). O remanescente dental foi acoplado à cortadeira metalográfica ISOMET 1000 (Buehler, Lake Bluff, IL, USA), de forma a permitir a realização de secções transversais, destinados ao teste de microtração (Instron modelo 4411 - Instron Inc., Canton, MA, EUA), sendo tracionados a 0,5 mm/min até sua ruptura. A superfície fraturada foi classificada segundo o padrão de fratura após análise sob lupa estereoscópica Stemi SV 11 (Carl Zeiss Company - DSM-940 A, Oberkochen, Baden-Württemberg, Germany) em aumento de 40×. Os valores obtidos no teste de microtração, na análise dos tags e da camada híbrida correspondentes a cada espécime e grupo de estudo, foram submetidos à análise estatística, com a realização do teste de Correlação de Pearson, não sendo verificada correlação entre os valores de resistência de união e a espessura da camada híbrida e comprimento dos tags resinosos em nenhum dos sistemas adesivos estudados. / Abstract: The purpose of this study was to evaluate the possibility of the correlation between the hybrid layer thickness, the resin tag length, and the resin bond strength of a conventional and a self-etching adhesive system into sound dentin tissue. After "in vivo" restorative procedures were performed, each specimen was extracted and sectioned in a mesiodistal direction. One of the dental sections was then analyzed on a light microscope where the hybrid layer thickness and resin tag length were measured. For this experiment, the specimens were decalcified, embedded in paraffin and serially sectioned at a thickness of 6 μm. The sections were subsequently stained using Brown and Brenn stain for posterior analysis and for the measurement of the hybrid layer thickness and the resin tag length on a Zeiss Axiophot light microscope at 1000× magnification (Carl Zeiss Company - DSM-940 A, Oberkochen, Baden- Württemberg, Germany). The other section was mounted onto a metallographic cutter ISOMET 1000 (Buehler, Lake Bluff, IL, USA) and was sectioned. A microtensile test was subsequently performed (Instron modelo 4411 - Instron Inc., Canton, MA, USA) with a crosshead speed of 0.5 mm/min. The fractured surfaces were analyzed and the fracture pattern was characterized using a stereoscopic magnifying glass Stemi SV 11 at a 40× magnification (Carl Zeiss Company - DSM-940 A, Oberkochen, Baden- Württemberg, Germany). The results were subjected to Pearson Correlation Test and verified that the hybrid layer thickness and the resin tag length did not correlate with the bond strength of the adhesives systems. / Mestre
129

Atividade antibacteriana de sistemas adesivos dentinários autocondicionantes sobre bactérias cariogênicas /

Gondim, Juliana Oliveira. January 2006 (has links)
Orientador: Elisa Maria Aparecida Giro / Banca: Josemeri Hebling / Banca: Regina Maria Puppin Rontani / Resumo: A incorporação de agentes antibacterianos aos sistemas adesivos dentinários autocondicionantes tem sido proposta com o intuito de eliminar bactérias residuais presentes na dentina, prevenindo, assim, a recorrência de cárie. O presente trabalho teve como objetivo avaliar a atividade antibacteriana dos sistemas adesivos dentinários autocondicionantes: Clearfil Protect Bond (CPB), Clearfil SE Bond (CSEB), Xeno III (XIII) e Clearfil Tri-S Bond (C3SB), com e sem fotoativação, sobre bactérias cariogênicas, bem como a influência da dentina humana na atividade antibacteriana destes sistemas adesivos, utilizando o método de difusão em ágar. A solução de digluconato de clorexidina a 0,2% foi utilizada como controle positivo. O componente adesivo do CPB e do CSEB, o líquido A do XIII e o C3SB não apresentaram atividade antibacteriana quando aplicados sobre discos de papel. O conjunto primer e adesivo do CPB não fotoativado promoveu a maior inibição contra S. mutans (p<0,05), enquanto que com a fotoativação, não houve diferença entre esses componentes juntos e o primer isoladamente. Para o L. acidophillus, o primer do CPB apresentou a maior atividade antibacteriana nas duas condições de fotoativação (p<0,05). Quando os materiais foram aplicados sobre discos de dentina, somente a CHX promoveu efeito inibitório, o qual foi de menor intensidade do que quando aplicada sobre discos de papel (p<0,05). A CHX apresentou maior atividade antibacteriana sobre S. mutans quando comparado com L. acidophillus (p<0,05). Pode-se observar que a fotoativação reduziu significantemente a 18 atividade antibacteriana dos sistemas adesivos autocondicionantes, que a presença do MDPB no sistema adesivo dentinário é importante para a atividade antibacteriana sobre bactérias cariogênicas, e que a dentina atua como barreira de proteção eliminando ou reduzindo a ação antibacteriana de materiais odontológicos. / Abstract: The incorporation of antibacterial agents in self-etching dentin bonding systems has been introduced in attempts to eliminate dentin residual bacteria, preventing secondary caries. Therefore, the aim of this study was to evaluate the antibacterial activity of cured and uncured self-etching dentin bonding systems Clearfil Protect Bond (CPB), Clearfil SE Bond (CSEB), Xeno III (XIII) and Clearfil Tri-S Bond (C3SB), against S. mutans and L. acidophillus, by the agar disc-diffusion test, as well as to evaluate the influence of human dentin on their antibacterial activity. A 0.2% aqueous solution of chlorhexidine (CHX) was used as a positive control. CPB and CSEB bond component, liquid A of Xeno III and C3SB did not show any antibacterial activity when applied onto paper discs. The primer and bond set of uncured CPB presented the strongest inhibitory activity against S. mutans (p<0.05), however after light-activation, no difference was observed between these components together and when primer was applied individually. Independently of light-activation conditions, CPB primer showed the strongest antibacterial activity against L. acidophillus (p>0.05). When the materials were applied onto dentin discs, only CHX presented inhibitory activity, which was less intense than when it was applied onto paper discs (p<0.05). CHX showed stronger antibacterial activity against S. mutans than against L. acidophillus (p<0.05). In conclusion, light-activation significantly reduced the antibacterial activity, the presence of MDPB in adhesive systems is important to the inhibitory effect against cariogênico 20 bacteria, and the dentin acted as a protection barrier reducing or inhibiting the antibacterial activity of dental materials. / Mestre
130

Comparação da resistência de união de diferentes superfícies dentinárias na obtenção dos espécimes para microtração / Effect of different dentin surfaces on the microtensile bond strength values

Maria Angelica Silverio Agulhari 18 May 2015 (has links)
Com intuito de aumentar a longevidade das restaurações, diversos sistemas adesivos são disponibilizados no mercado e, com isso, muitos estudos são conduzidos, dentre eles, a resistência de união desses sistemas. A maioria dos trabalhos utiliza o teste de microtração. Este teste permite a avaliação de diferentes superfícies, gerando variedade nos resultados obtidos e dificultando a comparação de dados. Este estudo teve como objetivo comparar os valores de resistência de união para as diferentes superfícies de dentina utilizadas em testes de microtração (dentina planificada e dentina de paredes cavitárias, com túbulos dentinários dispostos predominantemente paralelos ou perpendiculares à interface adesiva). Foram utilizados 80 terceiros molares humanos, divididos aleatoriamente em 4 grupos e 2 subgrupos, de acordo com a superfície dentinária de obtenção dos espécimes e do sistema adesivo utilizado: G1 (PO) planificação da face oclusal (baixo fator C); G2 (PV) planificação da face vestibular (baixo fator C); G3 (CP) face pulpar de preparo cavitário oclusal (alto fator C); G4 (CV) face vestibular de preparo oclusal (alto fator C). Dois diferentes sistemas adesivos foram utilizados: convencional de 3 passos Adper Scotchbond Multi-Purpose (3M ESPE) e o autocondicionante de 2 passos Clearfil SE Bond (kuraray), resultando em 8 subgrupos (n=10): POSMp; POCf; PVSMp; PVCf; CPSMp; CPCf; CVSMp; CVCf. A resina composta (Filtek Z250 A3) foi inserida em dois incrementos horizontais. Após 48 horas, os dentes foram seccionados com disco diamantado para a obtenção dos palitos com área de seção transversal de ±0,8mm. Uma fatia de cada subgrupo foi separada para análise em MEV. Os espécimes foram fixados ao dispositivo de microtração tipo Bencor multi T adaptado à máquina de ensaios universal Instron. Uma força de tração com velocidade de 0,5 mm/min utilizando uma célula de carga de 500N foi aplicada. As superfícies fraturadas foram analisadas em Esteromicroscópio LeicaMZ6 para identificar e classificar o tipo de fratura. Os resultados foram submetidos ao teste ANOVA a 2 critérios e ao teste de Tukey com nível de significância de 5%, para cada tipo de adesivo. Os valores médios (MPa±dp) foram: POSMp: 44.51±9.28; PVSMp: 56.75±6.58; CPSMp: 27.88±5.71;CVSMp: 32.54±6.11; POCf: 48.34±8.09; PVCf: 52.51±10.18; CPCf: 23.06±5.93; CVCf: 31.35±4.03. Houve diferença estatisticamente significante para o tipo de preparo (p<0.01 para ambos adesivos) e para a orientação dos túbulos dentinários (p<0,001 para o Scotchbond Multipurpose e p=0.012 para o Clearfil SE Bond).. Concluiu-se, portanto, que os espécimes obtidos a partir de cavidades apresentaram redução nos valores de resistência de união e a orientação paralela dos túbulos em relação à interface adesiva aumentou os valores de resistência de união à microtação. / Microtensile test is usually used to evaluate bond strength values and can be affected by several factors resulting in a diversity of values which makes it difficult to compare data. Flat surfaces dentin are used in most studies. However, specimens from a tooth cavity preparation can be a more realistic model. The aim of this study was to compare &#x3BC;TBS values of dentin flat surfaces (low C factor) and dentin from cavity preparations (high C fator) and its relation with the direction of the dentin tubules. Eighty extracted caries-free human molars were assigned into 4 groups: OF (occlusal flat surface specimens low C factor); BF (buccal flat surface specimens low C factor); PC (pulp surface of cavity preparations specimens high C factor) and BC (buccal surface of cavity preparations specimens high C factor). Each group was divided into 2 subgroups according to the adhesive system Adper Scotchbond Multi-Purpose (3M ESPE) or Clearfil SE Bond (Kuraray), resulting in 8 groups (n=10): OFSMp; OFCf; BFSMp; BFCf; PCSMp; PCCf; BCSMp and BCCf. Two horizontal increments of Filtek Z250 resin were used to restore the teeth. After 48 hours storage, the specimens were sectioned into 0.8 mm beams with diamond disc for microtensile test and submitted to a tensile force in a Universal Testing Machine (Instron) at 0.5mm/min. One slice of each subgroup was randomly selected for MEV. Mean values (MPa±sd) were OFSMp: 44.51±9.28; BFSMp: 56.75±6.58; PCSMp: 27.88±5.71; BCSMp: 32.54±6.11; OFCf: 48.34±8.09; BFCf: 52.51±10.18; PCCf: 23.06±5.93; BCCf: 31.35±4.03. Data were statistically analyzed by two-way ANOVA and Tukeys test (p<0.05) for each adhesive. The adhesive failures were predominant in all groups. It can be concluded that the microtensile bond strength was influenced by the type of dentin surface and tubules orientation. The specimens obtained from cavity preparations showed reduced &#x3BC;TBS (p<0.01). Parallel tubules orientation showed a statistically significant increase of &#x3BC;TBS (p<0.001 for Scotchbond Multipurpose and p=0.012 for Clearfil SE Bond).

Page generated in 0.0903 seconds