• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 181
  • 11
  • 6
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 1
  • 1
  • 1
  • Tagged with
  • 208
  • 208
  • 195
  • 175
  • 156
  • 75
  • 69
  • 68
  • 64
  • 54
  • 48
  • 40
  • 39
  • 35
  • 35
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
151

CORRELAÇÃO ENTRE GRAU DE CONVERSÃO E RESISTÊNCIA DE UNIÃO DE SISTEMAS ADESIVOS AUTOCONDICIONANTES / CORRELATION BETWEEN DEGREE OF CONVERSION AND BOND STRENGTH OF THE SELF-ETCHING ADHESIVE SYSTEM

Borges, Marciano de Freitas 24 February 2010 (has links)
Objective: The aim of this study was to analyses the relationship between the degree of conversion of double bonds of self-etching adhesives and microshear bond strength on dentin. Materials and methods: For microshear testing twenty third molar caries free were selected. They had their crowns sectioned longitudinally so as to obtain slices that were randomly chosen and divided into four groups according to the adhesive system, Single Bond (SB), Clearfil SEBond (CL) , Adhese (AD) and Gbond (GB). The slices were included into epoxy resin, and then cylindrical restorations were built with an area of 1.0 mm in diameter and 2.0 mm in height, around ten restorations per group, using a starch matrix. After 24 hours the specimens were tested for bond strength. To analyze the degree of conversion of these systems, a drop of adhesive was dispensed on a glass plate and after 20 seconds polymerized, forming a film of adhesive. After 24 hours, these films were pulverized and mixed with potassium bromide, pressed in a hydraulic press to form an insert for analysis with the spectrophotometer - FT-IR. The data of shear bond strength and degree of conversion of each specimen were submitted to ANOVA and Tukey s test (p = 0.05). Results: The SB adhesive system had mean values of bond strength statistically higher than AD and GB, but no statistical difference was found with Cl. Among the self-etching systems, the highest average shear bond strength was achieved with the application of the union CL, followed by GB and AD systems, which were not statistically different. Regarding the degree of conversion, similar statistical results were found for the systems SB and CL, and despite the SB had a higher average it, did not differ from CL. The adhesive system SB and CL showed higher values in AD and GB. The AD, showed values higher than the GB. Conclusion: The degree of conversion is affected by several factors related to the complex mixture of adhesive systems, which somehow contribute to their bond strength. / Objetivo: O objetivo desse estudo foi avaliar o grau de conversão de sistemas adesivos autocondiconantes em dentina e correlacioná-los com a resistência ao teste de microcisalhamento. Materiais e Métodos: Para o ensaio de microcisalhamento foram selecionados vinte terceiros molares livres de cárie, os quais tiveram suas coroas seccionadas longitudinalmente de modo a se obter fatias, que, aleatoriamente, foram divididas em quatro grupos, de acordo com o sistema adesivo uilizado, Single Bond (SB), Clearfil SE Bond (CL), Adhese (AD) e Gbond (GB). As fatias foram incluídas em tubos de PVC com resina acrílica e, em seguida, foram construídas restaurações cilíndricas com uma área de 1,0 mm de diâmetro e 2,0 mm de altura, em torno de dez restaurações por grupo, por meio de uma matriz de amido. Após 24 horas, os corpos de prova foram submetidos ao ensaio de microcisalhamento. Para análise do grau de conversão desses sistemas, uma gota do adesivo foi dispensada sobre uma placa de vidro e, após 20 segundos, foram fotopolimerizadas, formando uma película de adesivo. Após 24h, essas películas foram pulverizadas e misturadas com brometo de potássio, prensadas em prensa hidráulica de modo a formar uma pastilha para análise no espectofotômetro - FT-IR. Os dados obtidos da resistência de união e do grau de conversão foram submetidos à análise de variância e teste de Tukey (p = 0.05). Resultados: O sistema de união SB apresentou valores médios de resistência de união ao microcisalhamento estatisticamente superior AD e GB, mas não apresentou diferença estatística em relação ao sistema Cl. Dentre os sistemas autocondicionantes, as maiores médias no ensaio mecânico foram obtidas com a aplicação do sistema de união CL, seguido pelos sistemas AD e GB, que não foram estatisticamente diferentes entre si. Em relação ao grau de conversão, resultados estatísticos semelhantes foram encontrados para os sistemas SB e CL, que, apesar do SB apresentar uma maior média, não diferiu do CL. O sistema adesivo SB e CL apresentaram valores médios superiores ao AD e GB. O AD, que por sua vez, apresentou valores médios maiores que o GB. Conclusão: O grau de conversão é afetado por diversos fatores relacionados à mistura complexa dos sistemas adesivos, que, de certo modo, repercutirá na sua resistência de união.
152

Influencia dos modos de ativação no grau de conversão, resitencia e morfologia da interface de união de sistemas de cimentação e adesivos / Effect of different activation modes on the degree of conversion, tensile bond strength and interfacial morphology of dual-cured cementing systems used in indirect composite restorations

Arrais, Cesar Augusto Galvão 14 December 2006 (has links)
Orientador: Marcelo Giannini / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ondontologia de Piracicaba / Made available in DSpace on 2018-08-08T01:52:29Z (GMT). No. of bitstreams: 1 Arrais_CesarAugustoGalvao_D.pdf: 8768801 bytes, checksum: bf5f97c936134b9476bb797b23d446d6 (MD5) Previous issue date: 2006 / Resumo: A não fotoativação do sistema adesivo previamente à aplicação do cimento resinoso tem sido proposta quando sistemas de cimentação de dupla ativação (SCDA - sistemas adesivos de dupla ativação / cimentos resinosos de dupla ativação) são utilizados. Entretanto, existe uma carência de relatos científicos a respeito da efetividade dos SCDA. Os objetivos deste estudo foram: 1- avaliar a resistência de união (RU) e a morfologia da interface de união de restaurações indiretas de compósito através da utilização da microscopia confocal laser quando os sistemas adesivos de dupla ativação foram ou não fotoativados previamente à aplicação dos cimentos resinosos; 2- analisar o grau de conversão (GC), através da Espectroscopia Infravermelha Transformada de Fourier (FTIR), e a RU de SCDAs quando a fotoativação não foi realizada ou atenuada pela presença da restauração indireta; 3- avaliar o GC e resistência coesiva de sistemas de união quando utilizados diferentes unidades de fotoativação (LEDs e de luz halógena). A RU e resistência coesiva foram avaliadas através do ensaio de microtração. Para a análise em microscopia confocal laser, diferentes corantes foram incorporados nos SCDAs previamente à sua aplicação. Para a análise do GC, os SCDAs foram aplicados na superfície do diamante da unidade de reflectância total atenuada acoplada ao espectrômetro infravermelho. O GC dos sistemas de união não relacionados aos SCDAs foi obtido utilizando-se filmes de resina adesiva. Os resultados demonstraram que a não fotoativação do sistema adesivo de dupla ativação previamente à cimentação não afetou a RU, e que os valores foram até superiores para um SCDA de 4ª geração quando o agente de união não foi fotoativado. A análise em microscopia confocal laser exibiu variação nas características morfológicas da interface de união, variando de acordo com o SCDA utilizado e com o modo de ativação de ambos componentes (sistema adesivo e cimento resinoso). Para alguns SCDAs, o GC foi reduzido pela presença do disco de compósito posicionado entre o SCDA e a ponta da unidade fotoativadora. A não fotoativação dos SCDAs resultou em GC inferiores aos obtidos com exposição direta da luz. A não fotoativação da maioria dos SCDAs também resultou em valores inferiores de RU, exceto quando um sistema de 4ª geração foi utilizado. A utilização de LED resultou em GC inferior ao obtido quando a luz halógena foi utilizada mas não afetou a resistência coesiva dos sistemas adesivos avaliados. Pode-se concluir que a não fotoativação dos sistemas adesivos é uma alternativa aceitável durante a cimentação de restaurações indiretas, porém os SCDAs necessitam de luz fotoativadora para garantir adequada RU. A utilização de LEDs pode comprometer o GC dos sistemas adesivos / Abstract: The lack of light-activation of dual-cured bonding agents before the resin cement application has been an alternative technique of cementing indirect restorations when dual-cured cementing systems are used (DCS ¿ dual-cured bonding agents / dual-cured resin cements). However, few reports exist regarding the effectiveness of DCS when dual-cured bonding agents are left in the uncured state before the seating of the indirect restoration. Therefore, the aims of this study were: 1- to evaluate the microtensile bond strength (MTBS) and micromorphology of the adhesive interface of indirect restorations by confocal laser microscopy (CLSM) when the dual-cured bonding agents were left in the uncured state; 2- to analyze the degree of conversion (DC) by Fourier Transformed Infrared Spectroscopy and the bond strength of indirect restorations when DCSs were applied to the tooth and light activated or allowed to self-cure; 3- to evaluate the DC and ultimate tensile strength (UTS) of bonding agents light-activated with light curing units (LEDs and halogen light). The MTBS and UTS were analyzed using microtensile bond strength test. Different dyes were incorporated to the DCSs before they were applied to teeth for the CSLM analysis. For the DC analysis, the DSCs were applied to the diamond surface of attenuated total reflectance unit of the infrared device. The DC of the bonding agents related to the study evaluating the effectiveness of light-curing units was obtained from thin resin adhesive films. The results demonstrated that the MTBS was not affected, and the values were even higher for one 4th generation DCS, when the dual-bonding agents were left in the uncured state before the resin cement application. The CLSM analysis exhibited some variation in the micromorphological features, which depended on the DCSs and on the curing modes of bonding agents and resin cements. Some DCSs showed lower DC when pre-cured resin composite discs were used. The self-cured groups exhibited lower MTBS than the light-activated ones, except for one 4th generation DCS. The LED promoted lower DC in all bonding agents than did the halogen light. No difference in UTS was observed when LED was used. It was concluded that leaving the dual-cured bonding agent in the uncured state before seating the indirect restoration may be a reliable technique to ensure adequate MTBS, but most DCSs should be light-activated after seating the indirect restoration to provide optimal bond strength. Some LEDs can compromise the DC of adhesive systems / Doutorado / Dentística / Doutor em Clínica Odontológica
153

Influência da incorporação de antioxidantes em diferentes sistemas adesivos na resistência de união à dentina e nanoinfiltração / Influence of antioxidants incorporation into the different adhesive systems on dentin bond strength and nanoleakage

Gotti, Valéria Bisinoto, 1988- 22 August 2018 (has links)
Orientador: Américo Bortolazzo Correr / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-22T02:50:31Z (GMT). No. of bitstreams: 1 Gotti_ValeriaBisinoto_M.pdf: 22569671 bytes, checksum: 63a18f68fe04710cbb552ebb07904779 (MD5) Previous issue date: 2013 / Resumo: O resumo poderá ser visualizado no texto completo da tese digital / Abstract: The abstract is available with the full electronic document / Mestrado / Materiais Dentarios / Mestra em Materiais Dentários
154

Microleakage in new resin-modified glass ionomer cements using new no-rinse conditioners : an in-vitro study

Patel, Ashish G. January 2012 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / Since their introduction in 1970, glass ionomer cements have been used in a wide variety of clinical situations in dentistry. The main advantages of glass ionomer cements are chemical bonding, fluoride release and uptake, excellent seal against microleakage, and biocompatibility. The main objective of this study was to compare the microleakage of two new paste-paste glass ionomer systems to their traditional RMGIC counterparts when conditioning the dentin with newly developed no-rinse conditioners or polyacrylic acid. Materials and methods: Standardized cavity preparations were made, centered on the cementoenamel junction of the buccal surface, on 96 extracted human molars divided in 8 groups (n = 12). G1 Ketac Nano with Ketac Nano Primer, G2 Ketac Nano with Ketac Conditioner, G3 Photac Fil with Ketac Nano Primer, G4 Photac Fil with Ketac Cavity Conditioner, G5 Fuji Filling LC with GC Self Conditioner, G6 Fuji Filling LC with GC Cavity Conditioner, G7 Fuji II LC with GC Self Conditioner, G8 Fuji II LC with GC Cavity Conditioner. The cavities were treated with either a no-rinse or polyacrylic acid conditioner and restored with a paste-paste RMGIC or traditional RMGIC from the same manufacturer (n =12). The teeth were then sealed to within 2 mm of the restoration margins and thermocycled. The teeth were immersed in 2.0-percent methylene blue and stored at room temperature for 24 hours. Then, the teeth were be embedded in resin and sectioned longitudinally in a buccolingual direction making 1 section (1 mm thick) per tooth. The occlusal and gingival restoration margins of each specimen were examined with a stereomicroscope at X10 magnification to determine the degree of microleakage. Results: Mixed-model ANOVA was used to test the fixed effect of the eight groups and cervical vs. occlusal location within each tooth sample on microleakage, with sample as the random effect. Both main effects and the interaction are significant, p < 0001 for both group and location effects, and p = 0.0013 for the interaction of group and location. The cervical interface showed more microleakage in all groups except group 8 where microleakage was the same as at the occlusal margin. No significant difference was observed among groups for microleakage at the occlusal interface. There was significant difference among groups at the cervical interface with Fuji II LC using GC Cavity Conditioner performing best. For the occlusal interface Group 4 performed the best and Group 2 performed the worst, although the difference was not significant among the groups. For the cervical interface, Group 8 performed the best followed by Group 3, Group 4 and Group 6, although these four groups were not significantly different. For the cervical interface, group 2 performed the worst followed by group 1. Based on these results we can conclude that, overall, traditional RMGIC with polyacrylic acid conditioning performed better than the new paste-paste RMGIC systems utilizing the no-rinse conditioners.
155

Efeito de diferentes modelos de envelhecimento na resistência de união em dentina decídua hígida e cariada / Different degradations models to evaluate bond strength in sound and caries primary dentin

Calvo, Ana Flávia Bissoto 04 March 2015 (has links)
A resistência de união (RU) dos materiais deve ser avaliada após a degradação da interface adesiva, tentando simular um processo que ocorre naturalmente ao longo do tempo na cavidade bucal. O presente estudo avaliou a degradação da interface adesiva em diferentes materiais utilizando o modelo de envelhecimento in vitro e in situ em dentina hígida e cariada. Noventa segundos molares decíduos hígidos e sem defeitos de esmalte, foram aleatoriamente divididos em dois grupos de acordo com o substrato a ser testado (hígido e com lesão de cárie induzida). A seguir, cada um dos grupos foi subdividido aleatoriamente de acordo com o material restaurador (n=15): resina composta associada ao sistema adesivo - RC, cimento de ionômero de vidro modificado por resina - CIVMR e cimento de ionômero de vidro de alta viscosidade - CIVAV. A superfície da dentina foi preparada e com o auxílio de cânulas de polietileno, foram confeccionados os espécimes com os materiais restauradores. Partes de um mesmo dente foram submetidas a cada envelhecimento: in vitro (24 horas e 6 meses) - armazenados em água destilada à 37°C; e in situ (uso de dispositivo intraoral palatino por voluntários em uma fase experimental de 7 dias). Os espécimes foram submetidos ao teste de microcisalhamento (MPa) para avaliação da RU, seguido de análise do padrão de fratura em estereomicroscópio (400X). Os dados foram submetidos a análise de variância de medidas repetidas seguida pelo teste de Bonferroni (? = 5%). De forma geral, o armazenamento por seis meses em água degradou o grupo CIVMR em dentina hígida (<0,001) e RC em dentina cariada (p=0,007), para os outros materiais não houve diferença estatística (p=1,00). O modelo in situ influenciou negativamente os valores de RU nos grupos RC e CIVMR (p<0,001) no substrato hígido e na RC (p<0,001), CIVMR (p=0,001) e CIVAV p=0,020) no substrato cariado. Concluí-se que no modelo in vitro, seis meses em água destilada não foram suficientes para degradar a interface de união dos materiais avaliados e o modelo in situ é uma metodologia rápida que pode ser utilizada para avaliar a degradação da interface de união de materiais restauradores em dentina cariada de dentes decíduo. / Materials bond strength (BS) should be evaluated after degradation of the adhesive interface, simulating the intra-oral enviroment. This study assessed the degradation of the bonding interface of differents materials using in vitro and in situ models of aging in sound and caries - affected primary dentin. Ninety sound second primary molars without enamel defects were randomly assigned into two groups (sound and induced carious) according to the substrate to be tested. Then each group was subdivided according to the restorative material (n=15): composite resin associated with the adhesive system - CR, resin-modified glass ionomer cement - RMGIC or high-viscous glass ionomer cement- HVGIC. Dentin surface was prepared and with the aid of polyethylene tubes specimens of each restorative materials were prepared. Parts of a same tooth were subjected to in vitro and in situ models of aging. For in vitro model, the specimens were stored in distilled water at 37°C during 24 hours per 6 months; and for in situ model an intraoral palatal device was confectioned and used by volunteers in an experimental phase for 7 days. Specimens were submitted to microshear test (MPa) for BS evaluation and then stereomicroscopy (400X) analys of failure mode. Data were analyzed by repeated measures ANOVA for followed by Bonferroni test (? = 5%). In general, the storage for six months in distilled water degraded the RMGIC group in sound dentin (<0.001) and RC group in caries-affect dentin substrate (p = 0.007), for the others materials there was no statistical difference (p = 1.00). The in situ model, adversely, influenced the BS in RC and RMGIC groups (p <0.001) in sound substrate, and in RC (p <0.001), RMGIC (p = 0.001) and HVGIC (p = 0.020) in caries-affected dentin. We can concluded that in in vitro model, using six months distilled water, was not sufficient to degrade the bonded interface of the evaluated materials and in situ model is a faster method to evaluate degradation of the adhesion interface of restorative materials in cariesaffected dentin.
156

Efeito da irradiação com laser de diodo sobre adesivos dentinários / Effect of diode laser irradiation on dentin-bonding agents

Maenosono, Rafael Massunari 10 May 2017 (has links)
A irradiação de sistemas adesivos com laser tem obtido resultados promissores, no entanto, seu mecanismo de ação, bem como a longevidade da camada híbrida obtida após a irradiação com laser ainda não estão bem estabelecidos na literatura. A presente tese teve como objetivo: avaliar a absorvância do laser de Diodo por diferentes sistemas adesivos por meio de espectroscopia no infravermelho próximo; avaliar a evaporação de água e solventes proporcionada pelo laser por meio da variação da massa analisada em balança de precisão; avaliar a resistência de união por meio de teste de microtração após envelhecimento de 12 meses. Os dados obtidos foram analisados por modelos de ANOVA, seguidos de teste Tukey (p<0,05) e os resultados demonstraram que: a irradiação no infravermelho próximo, área do espectro eletromagnético que compreende o laser de Diodo, não apresenta interação com os sistemas adesivos testados; o laser de Diodo é capaz de proporcionar maior alteração de massa, mesmo após contínua evaporação dos solventes com jatos de ar por 60s; sistemas adesivos simplificados apresentaram valores de resistência de união imediato semelhantes aos valores obtidos após 12 meses de envelhecimento. Os dados obtidos neste estudo sugerem que a irradiação com laser de Diodo pode contribuir favoravelmente para a adesão em dentina com sistemas adesivos simplificados após 1 ano. / The laser irradiation of adhesive systems has obtained promising results, however, its mechanism of action, as well as the longevity of the hybrid layer obtained after laser irradiation are still not yet well established in the literature. This thesis aimed to: assess the diode laser interaction with different adhesive systems by means of near infrared spectroscopy; evaluate the evaporation of solvents and water provided by the laser through the mass variation analyzed at a precision balance; evaluate the bond strength through microtensile bond strength test after 12 months of aging. The data was analyzed through ANOVA models, followed by Tukey test (p<0.05), and the results demonstrated that: in the near-infrared irradiation area, the electromagnetic spectrum comprising the diode laser, shows no interaction with the adhesive systems tested; the diode laser was able to provide greater mass variation, even after continual evaporation of solvents with air jets for 60s; simplified adhesive systems presented immediate bond strength values similar to the ones verified after 12 months of aging. The data obtained in this study suggest that the Diode laser irradiation can contribute favorably for the adhesion between dentin and simplified adhesive systems after 1 year.
157

Resistência de união de um cimento resinoso a diferentes superfícies de alumina densamente sinterizada / Shear bond strenght of a resin cement to different surfaces of densely sintered alumina

Valdivia, Juan Rommel Medina 20 June 2007 (has links)
O propósito deste estudo foi avaliar a resistência adesiva ao cisalhamento de um cimento resinoso à alumina densamente sinterizada testando o tratamento superficial feito pelo fabricante. O cimento utilizado foi o Multilink (Ivoclar Vivadent) e a alumina foi a Procera®Alumina (Nobel Biocare) constituída por 99,9 % de óxido de alumínio densamente sinterizado. Trinta e dois cilindros de alumina foram confeccionados pela Nobel Biocare, onde um dos extremos deste cilindro recebeu o tratamento superficial e o outro não. Para a aplicação do cimento resinoso sobre os cilindros de alumina, utilizou-se uma matriz de Teflon com um orifício central de 3,5mm de diâmetro por 3,0mm de profundidade. Foram determinados 4 grupos experimentais: Grupo 1 superfície sem tratamento; Grupo 2 superfície sem tratamento e com aplicação de adesivo; Grupo 3 - superfície com o tratamento realizado pelo fabricante; Grupo 4 superfície com tratamento realizado pelo fabricante e com adesivo. Após a aplicação do cimento nos 4 grupos, os espécimes foram armazenados em água deionizada a 37ºC durante 24h, sendo, em seguida, montados em uma máquina universal de ensaios para realização dos testes de resistência ao cisalhamento. Os resultados foram submetidos à análise de variância a dois critérios e ao teste de Tukey para comparação entre os grupos. A superfície tratada (grupo 3) apresentou valores significativamente maiores que todos os outros grupos. A presença do adesivo diminuiu a resistência adesiva quando aplicado na superfície tratada, mas não deu diferença significante quando aplicado na superfície sem tratamento. / The aim of this study was to investigate the shear bond strength between a resin cement and densely sintered alumina treated by the fabricant. The resin cement used was the Multilink (Ivoclar Vivadent) and the alumina the Procera®Alumina (Nobel Biocare) made with 99,9% of densely sintered aluminum oxide. Thirty two alumina cylinders were made by Nobel Biocare, and in one of the extremes was applied a own`s fabricant surface treatment. For the application of the cement, a Teflon matrix with a central hole (diameter of 3,5 mm and a height of 3,0 mm) was used. Four groups were created: Group 1 surface without treatment; Group 2 - surface without treatment and with adhesive; Group 3 surface with the own`s fabricant treatment; Group 4 - surface with the own`s fabricant treatment with adhesive. After the cement application, the specimens were stored in water at 37º C for 24 hours. Then the samples were placed in a universal testing machine for making the shear strength test. Statistical analysis was performed with two-way analysis of variance (ANOVA), and paired comparisons between groups were done with Tukey`s multiple comparison. Higher significant values were detected for Group 3 when compared with all the other groups. The adhesive decreased the shear bond strength when laid on the treated surface, and there were no difference when laid on the untreated surface.
158

Adaptação marginal de restaurações em resina composta expostas a diferentes agentes clareadores / Marginal adaptation of resin composite restorations exposed to bleaching agents

Abe, Andréa Tami 09 April 2018 (has links)
Este estudo teve como objetivo avaliar a adaptação marginal de restaurações em resina composta confeccionadas utilizando-se como agentes adesivos sistemas de diferentes estratégias de interação, expostas a agentes clareadores e submetidas a ciclagem mecânica, por meio de avaliação em tomografia por coerência óptica (OCT). Para este estudo foram utilizados 90 molares humanos hígidos recém-extraídos. Uma cavidade classe V foi confeccionada na face vestibular de cada dente com a margem oclusal localizada em esmalte e a margem cervical em cemento/ dentina. Os espécimes foram divididos em 3 grupos experimentais, de acordo com o sistema adesivo utilizado (SB2: Single Bond 2, SBU: Single Bond Universal e CSE: Clearfil SE Bond). As cavidades foram então preenchidas com a resina composta nanoparticulada Filtek Z350XT, e em seguida o acabamento e o polimento foram realizados. Os espécimes foram submetidos a duas ciclagens mecânicas, sendo a primeira antes e a segunda após o clareamento. Ao final da primeira ciclagem, os espécimes foram subdivididos em 3 grupos (n=10) de acordo com o tratamento realizado (controle - água destilada, HPB: Whiteness HP Blue - pH 8.8, PO: Pola Office - pH 3.6). As imagens em OCT das restaurações foram obtidas em 4 momentos diferentes (antes da primeira ciclagem, depois da primeira ciclagem, após o tratamento e depois da segunda ciclagem). A interface dente-restauração foi analisada de duas formas, por meio de classificação das fendas por escore e mensuração da profundidade da fenda em micrômetros (?m), para esmalte e dentina separadamente. Os valores de escore foram analisados com o teste estatístico não-paramétrico de Kruskal-Wallis (p<0.05), e para os dados de profundidade de fenda em ?m, a ANOVA dois fatores (p<0.05) e teste de Tukey foram empregados. A correlação de Spearman foi empregada para correlacionar esses dois dados e foi observada uma correlação forte entre os dados de escore e de profundidade em ?m (r=0.85 p<0.0001). A comparação entre os grupos, tanto por escores quanto por profundidade em ?m, demonstraram que as fendas observadas após a primeira ciclagem foram estatisticamente maiores (p<=0.05) do que as fendas observadas inicialmente, exceto para a análise por escores, onde essa diferença foi detectada apenas para o adesivo SB2. O adesivo SBU apresentou as menores fendas marginais tanto em esmalte quanto em dentina. Em esmalte o adesivo CSE mostrou-se mais estável à degradação e em dentina não foi observada diferença estatisticamente significante entre os adesivos CSE e SB2. Entre os diferentes tratamentos, nenhuma diferença foi observada, independente do tempo de análise e do adesivo utilizado. Pode-se concluir que os clareadores utilizados não promoveram alteração da integridade marginal das restaurações em resina composta, sendo que as fendas marginais observadas estão mais relacionadas ao efeito do envelhecimento por ciclagem mecânica e são dependentes do sistema adesivo utilizado. Foi observada correlação direta entre os dois métodos de análise para mensuração da fenda marginal, contudo a análise da profundidade em ?m, utilizando teste paramétrico, mostrou-se mais sensível para a detecção de diferenças. / The aim of this study was to evaluate the marginal adaptation of resin composite restorations using different dental adhesive systems, exposed to dental bleaching agents and mechanical load cycling, by evaluation using optical coherence tomography (OCT). For this study 90 sound recently extracted human molars were used. One class V cavity was prepared in the buccal surface of each tooth with occlusal margin in enamel and cervical margin in dentin. The specimens were divided into 3 experimental groups, according to the adhesive system used (SB2: Single Bond 2, SBU: Single Bond Universal e CSE: Clearfil SE Bond). The cavities were restored with the nanocomposite Filtek Z350XT, and then the finishing and polishing were done. The specimens were submitted to two mechanical load cycling, the first one before bleaching and the second one after it. By the end of the first load cycling, the specimens were subdivided into 3 groups (n=10) according to the treatment accomplished (control - distilled water, HPB: Whiteness HP Blue - pH 8.8, PO: Pola Office - pH 3.6). The OCT images of the restorations were obtained in 4 distinct moments (before the first load cycling, after the first load cycling, after the treatment, and after the second load cycling). The tooth-restoration interface was analyzed by two ways: analyzing the gap by score and measurement of the gap depth in micrometer (?m), for enamel and dentin separately. The scores were analyzed with the non-parametric statistic test Kruskal-Wallis (p<0.05), and for the gap depth data, the two-way ANOVA (p<0.05) and Tukey test were used. The Spearman correlation were done to correlate these two data and a strong correlation between the score analysis an depth in ?m was observed (r=0.85 p<0.0001). The comparison between the groups, as by score as by depth in ?m, demonstrated that the gaps observed after the first load cycling were statistically deeper (p<=0.05) than the gaps observed initially, except for score analysis, when this difference was detected only for the adhesive SB2. The adhesive SBU showed less deep marginal gaps both in enamel and dentin. In enamel, the adhesive CSE was more stable to degradation and in the dentin no statistically difference was observed between the adhesives CSE and SB2. Between the different treatments, no difference was observed, regardless the evaluation time and the dental adhesive used. In conclusion, the bleaching agents used in this study did not affect the marginal integrity of resin composite restorations, thus the marginal gaps observed were more related to the aging by mechanical load cycling and were dependent of the dental adhesive system used. There was a direct correlation between both methods for marginal gap analysis, however the depth in ?m analysis, using parametric statistical test, showed more sensitive to detect differences.
159

Efeito da contaminação por saliva humana na interface adesiva: resistência de união, análise de camada híbrida e conversão de sistemas adesivos / Effect of human saliva contamination on adhesive interface: bond strength, hybrid layer analysis and conversion of adhesive systems

Villavicencio Espinoza, Carlos Andres 03 July 2017 (has links)
Este estudo teve como objetivo analisar o efeito da contaminação por saliva humana na resistência de união (RU) da interface adesiva em dentina por microtração, nas características morfológicas da camada híbrida (CH) em microscopia confocal e no grau de conversão (GC) de 2 sistemas adesivos: Adper Single bond 2 (SB) e Single Bond® Universal (SU). Cento e oitenta dentes terceiros humanos hígidos foram divididos em 12 grupos (n=10), de acordo com o sistema adesivo utilizado, a presença de saliva e o tempo de armazenagem. Após o procedimento adesivo e aplicação da resina composta Filtek Z250, os dentes foram mantidos em água destilada em estufa a 37°C por 48 horas, 6 meses ou 12 meses antes de serem seccionados em palitos (0,8mm x 0,8mm, aproximadamente) para serem levados à máquina de ensaios universal Instron para os testes de microtração. Para à análise da interface adesiva em microscopia confocal de varredura a laser para verificação e mensuração de alterações internas na interface foram utilizados 60 dentes divididos em 6 grupos (n=10) de acordo com os tempos de 48 horas, 6 meses, e 12 meses respectivamente, empregando os sistemas adesivos (SB) e (SU). O efeito da presença de saliva também foi avaliado pelo grau de conversão dos adesivos, empregando-se espectroscopia de infravermelho transformada de Fourier empregando os sistema adesivos (SB) e (SU) com incorporação de saliva humana na sua composição (n=5) com concentrações 10%, 25% e 50% em vol. Para a comparação das variáveis: RU, (GC), espessura da CH, na presença de saliva e tempo de armazenamento foram utilizados os testes de Análise de Variância a três critérios e de comparações múltiplas de Tukey (p<0,05). Os valores de RU (MPa±dp: 48horas/6meses/1ano) foram: SB (43,53 ±6,0; 40,10±3,4; 38,59±5,4); SalSB (43,09±6,2; 39,86±6,6; 37,255,8); SU (42,98±4,3; 39,30±3,6; 40,44±5,7); Sal SU (44,39±4,2; 42,26±2,5; 38,26±5,7). Os Valores médios da CH (MPa±dp: 48horas/6meses/1ano) foram: SalSB (3,59±0,8; 3,59±1,0; 2,08±1,5). SalSU (1,26±0,5; 1,73±0,8; 1,07±0,3). Os valores de GC (MPa±dp: 10%/25%/50%vol) foram: SB (85,59±3,4; 49,68±12,8; 38,56±11,8); SU (85,52±3,3; 86,27±3,5; 57,82±11,1).Conclui-se, portanto, que a contaminação por saliva humana não interferiu na RU da interface dentina/resina composta após 48 horas, 6 meses e 12 meses. A morfologia da camada hibrida foi alterada pela presença da saliva nos períodos 6 e 12 meses,. O GC dos sistemas adesivos foi afetado pela presença de saliva após a polimerização imediata. Entretanto o fator tempo foi determinante para a deformação da interface dentina/resina para ambos os sistemas adesivos. / The objective of this study was to analyze the effect of human saliva contamination on bond strength of the dentin/adhesive interface, morphology of the hybrid layer by confocal microscopy and SEM analysis and degree of conversion of 2 adhesive systems: Adper Single bond 2 (SB) and Single Bond® Universal ( SU). One hundred and eighty healthy human third teeth were divided into 12 groups (n = 10), according to the adhesive system used, the presence of saliva and the storage time. After the adhesive procedure and placement of resin composite (Filtek Z250), the teeth were stored in distilled waterat 37 ° C for 48 hours, 6 months or 12 months before being cut into sticks (0.8mm x 0.8mm, approximately) to the microtensile strength tests. For the analysis of the adhesive interface in confocal microscopy of laser scanning for verification and measurement of internal interface changes, 60 teeth were used divided into 6 groups (n = 10) according to the storage time: 48 hours, 6 months, and 12 monthsand (SB) and (SU). The effect of the presence of saliva was also evaluated by the degree of conversion of the adhesives using Fourier transform infrared spectroscopy employing adhesive (SB) and (SU) systems incorporating human saliva in its composition (n = 5) with 10%, 25% and 50% vol. For the comparison of the variables: bond strength, degree of conversion, and hybrid layer thickness in the presence of saliva and storage time, the three criteria Variance Analysis and Tukey multiple comparisons tests (p <0.05) were used. The values of bond strength (MPa ± dp: 48hours / 6meses / year) were: SB (43.53 ± 6.0, 40.10 ± 3.4, 38.59 ± 5.4); SalSB (43.09 ± 6.2, 39.86 ± 6.6, 37.255.8); SU (42.98 ± 4.3, 39.30 ± 3.6, 40.44 ± 5.7); SU salt (44.39 ± 4.2, 42.26 ± 2.5, 38.26 ± 5.7). The mean values of hybrid layer thickness (MPa ± dp: 48hours / 6meses / year) were: SalSB (3.59 ± 0.8, 3.59 ± 1.0, 2.08 ± 1.5). SalSU (1.26 ± 0.5, 1.73 ± 0.8, 1.07 ± 0.3). The values of degree of conversion (MPa ± dp: 10% / 25% / 50% vol) were: SB (85.59 ± 3.4, 49.68 ± 12.8, 38.56 ± 11.8); (85.52 ± 3.3, 86.27 ± 3.5, 57.82 ± 11.1). It was therefore concluded that human saliva contamination did not interfere on bond strength of the dentin/adhesive interface after 48 hours, 6 months and 12 months. The morphology of the hybrid layer was altered by the presence of saliva after 6 and 12 months. The degree of conversion of adhesive systems was affected by the presence of saliva immediately after polymerization. However, the time factor was determinant for the dentine/resin interface deformation for both adhesive systems.
160

ALTERNATIVAS PARA MELHORAR AS PROPRIEDADES ADESIVAS DE SISTEMAS ADESIVOS UNIVERSAIS EM DENTINA EROSIONADA / Alternatives to improve the adhesive properties of universal adhesive systems in eroded dentin

Siqueira, Fabiana Suelen Figueredo de 07 April 2017 (has links)
Made available in DSpace on 2017-07-24T19:22:05Z (GMT). No. of bitstreams: 1 FABIANA SIQUEIRA.pdf: 4384235 bytes, checksum: 655ceab1a73a43f410cdb4b5e3773475 (MD5) Previous issue date: 2017-04-07 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim of the present study was evaluate the adhesive properties of eroded dentin with different pH cycling using universal adhesive systems and to evaluate the application of collagen cross-linking agent or MMP inhibitors on the resin-eroded dentin interface, through of three in vitro studies. For the experiment 1, the teeth were randomly assigned into the experimental groups according to the combination of variables: dentin surface (sound dentin and eroded dentin) vs adhesive systems (10 universal adhesives) vs Adhesive strategy [etch-and-rinse (ER) and self-etch (SE)]. The adhesive systems were applied according to the manufacturer's instructions and the teeth were restored. They were sectioned to analysis of microtensile bond strength (μTBS) and nanoleakage (NL). The surfaces of 2 tooth were examined under scanning electron microscopy (SEM) to evaluate the surface characterization after erosive-cycling. For experiment 2, the teeth were randomly assigned into 18 experimental conditions according to the variables: Erosive cycling (eroded dentin with soft drink pH ≈ 2,7 and eroded dentin with citric acid pH 2.3) vs. adhesive systems [Prime & Bond Elect (PBE); Scotchbond Universal Adhesive (SBU); Tetric N-Bond Universal (TEU)] vs Treatment agents [6.5% primer containing proanthocyanidin (PA) and 0.1% riboflavin (RI)]. The surface was treated with primers and the adhesive systems were applied and restored. The samples were sectioned and tested for μTBS, NL and degree of conversion (DC). The surfaces of 2 tooth were examined under SEM to evaluate the surface characterization after erosive-cycling. For experiment 3, the teeth were randomly assigned into 18 experimental conditions according to the variables: Erosive cycling (eroded dentin with soft drink pH ≈ 2,7 and eroded eroded with citric acid pH 2.3) vs. Adhesive Systems (PBE; SBU; TEU) vs Acid pretreatment [control with 37% phosphoric acid;Phosphoric acid containing 2% chlorhexidine (CHXacid) and phosphoric acid containing 3% PA (PAacid)]. The teeth were acid-etched according to each experimental conditions, the adhesive systems were applied and the teeth were restored. The teeth were sectioned and tested for μTBS, NL and DC. Data were submitted to appropriate statistical analysis (α = 0.05). The μTBS values in eroded dentin were statistically lower than sound dentin, independent of the adhesive strategy (p < 0.01) The inclusion of primers containing collagen cross-linking agents in the eroded dentin adhesive protocol improved μTBS values (p <0.001),significantly reduced NL (p <0.004) for all the adhesives tested, as well as improved DC (p <0.03). The use of phosphoric acids containing MMPs inhibitors or collagen cross-linking agent improved μTBS values (p> 0.33), produced a significant reduction of NL (p <0.004) and improved DC (p <0.03). The application of MMP inhibitors (primer or acid etching - containing) were effective to improve the properties of the resin-eroded dentin interface. / O objetivo desse estudo foi avaliar as propriedades adesivas à dentina erosionada utilizando sistemas adesivos universais e verificar o efeito da aplicação de agentes reticuladores de colágeno ou inibidores de Metaloproteinases (MMPs) na interface resina-dentina erosionada, através de três estudos laboratoriais. Para o experimento 1, os dentes foram distribuídos aleatoriamente entre os grupos experimentais de acordo com a combinação das variáveis: superfície dentinária (controle sem erosão e erosionada) vs. sistemas adesivos (10 sistemas adesivos universais) vs.estratégia adesiva [condicionamento convencional (ER) e autocondicionante (SE)].Os sistemas adesivos foram aplicados de acordo com as especificações do fabricante e os dentes foram restaurados. Depois foram seccionados para análise da resistência de união à dentina (μTBS) e nanoinfiltração (NI). A superfície de 2 dentes foi examinada sob microscopia eletrônica de varredura (MEV) para avaliar as características da superfície após ciclagem erosiva. Para o experimento 2, os dentes foram aleatoriamente alocados em 18 condições experimentais de acordo com as variáveis: Ciclagem erosiva (dentina erosionada com coca-cola pH ≈ 2,7 e dentina erosionada com ácido cítrico pH 2,3) vs. Sistemas adesivos [Prime & Bond Elect (PBE), Scotchbond Universal Adhesive (SBU) e Tetric N-Bond Universal (TEU)] vs. Agentes de tratamento [primer contendo 6,5% de roantocianidina (PA) e primer contendo 0,1% de riboflavina (RI)]. Os sistemas adesivos foram aplicados de acordo com as especificações do fabricante após aplicação do primer e restaurados. A seguir, os dentes foram seccionados e testados para análise da μTBS, NI e grau de conversão (GC). A superfície de 2 dentes foi examinada sob MEV para avaliar as características da superfície após erosão. Para o experimento 3, os dentes foram alocados aleatoriamente dentro de 18 condições experimentais de acordo com as variáveis: Ciclagem erosiva (dentina erosionada com coca-cola pH ≈ 2,7 e dentina erosionada com ácido cítrico pH 2,3) vs. Sistemas adesivos (PBE, SBU e TEU) vs. pré-tratamento ácido [controle com ácido fosfórico 37%; Ácido fosfórico contendo 2% de clorexidina (CHXacido) e ácido fosfórico contendo 3% de PA (PAacido)]. Os dentes foram condicionados de acordo com cada grupo experimental, os sistemas adesivos foram aplicados e restaurados com resina composta. Posteriormente, os dentes foram seccionados e testados para análise da μTBS, NI e GC. Todos os dados foram submetidos a ANOVA 3 fatores e teste de Tukey (α = 0,05). Os valores de μTBS em dentina erosionada foi estatisticamente inferior à dentina sadia,independente da estratégia adesiva (p > 0,61). A inclusão de primers contendo agentes reticuladores de colágeno no protocolo adesivo a dentina erosionada,melhorou os valores de μTBS (p < 0,001), diminuiu significativamente a NI (p <0,004) para os adesivos testados, além de melhorar o GC (p < 0,03). A utilização de ácidos fosfórico contendo inibidores de MMPs ou agentes reticuladores de colágeno melhorou os valores de μTBS (p > 0,33), produziu uma redução significativa da NI (p < 0,004) e melhorou o GC (p < 0,03). Os agentes reticuladores independente do veículo (primer ou condicionamento ácido) foram eficazes para melhorar as propriedades da interface resina-dentina erosionada.

Page generated in 0.0703 seconds