Spelling suggestions: "subject:"bonding agents"" "subject:"conding agents""
141 |
Influence of temporary cements on the bond strength of indirect restorations to dentin employing two resinous adhesive systems / InfluÃncia de cimentos provisÃrios sobre a resistÃncia de uniÃo de restauraÃÃes indiretas àdentina utilizando dois sistemas adesivos resinososJosà Carlos Viana Ribeiro 10 July 2007 (has links)
CoordenaÃÃo de AperfeiÃoamento de Pessoal de NÃvel Superior / The aim of this in vitro study was to evaluate the influence of residual temporary cements on the microtensile bond strength of indirect composite resin build-ups employing two types of adhesive systems. Thirty non-carious human third molars were selected and the occlusal enamel was removed to produce flat dentin surfaces. The surfaces were coated with provisional restorations fixed with either eugenol-containing temporary cement (Temp Bond), or non-eugenol temporary cement (Freegenol). After one week, the provisional restorations and residual cement were removed with a dental probe and one specimen of each group was selected for evaluation by atomic force microscopy to investigate the presence of remnants of temporary cements. For the control groups, no provisional restorations were made. The dentin surfaces were cleaned with pumice and treated either with a total-etch (TE) adhesive system (Adper Single Bond 2) or with a self-etch (SE) adhesive system (Adper Prompt). Composite resin build-ups (Filtek Z250) were fixed to the bonded dentin surfaces using resin luting cement (RelyX ARC). The bonded specimens were then cross-sectioned producing sticks of 0.9 mm2 of adhesive area. Microtensile bond strength testing was perfomed in a universal test machine at a rate of 0.5 mm/min until fracture occurred. Optical microscopic images and scanning electron micrographs of fractured surfaces were obtained and recorded for fractographic analysis. Bond strength values were submitted to analysis of variance (ANOVA) and t-Student tests to detect significant differences between groups. The results showed a significant reduction on microtensile bond strength values when Temp Bond cement was employed in comparison with the control groups either for TE (p = 0.0331) or SE (p = 0.0267) adhesive systems. Total-etch groups showed significantly higher bond strength values than self-etch groups (p < 0.0001). Optical and scanning electron microscopic analysis revealed a majority of mixed fractures (67%). Adhesive failure at dentin-adhesive interface was significantly higher for SE groups than for TE groups (p = 0.0001). Atomic force microscopic images showed that residues of both temporary cements remained on dentin surfaces even after mechanical cleansing and treatment with acids. Bond strengths of total-etch and self-etch adhesive systems were significantly lowered only when eugenol-containing temporary cement was used prior to bonding and cementation procedures. / O presente estudo experimental in vitro se propÃÂs a investigar a influÃÂncia de resÃÂduos de cimentos provisÃÂrios sobre a resistÃÂncia de uniÃÂo de restauraÃÂÃÂes indiretas de resina composta ÃÂ dentina, empregando-se dois sistemas adesivos resinosos, por meio de ensaio mecÃÂnico de microtraÃÂÃÂo. SuperfÃÂcies planas de dentina foram obtidas a partir da remoÃÂÃÂo do esmalte oclusal de 30 (trinta) dentes terceiros molares humanos sem lesÃÂes de cÃÂrie, extraÃÂdos por indicaÃÂÃÂo cirÃÂrgica ou ortodÃÂntica. Os espÃÂcimes foram distribuÃÂdos em 6 (seis) grupos, de acordo com o tipo de cimento provisÃÂrio e o tipo de sistema adesivo empregado. Discos de resina acrÃÂlica foram fixados ÃÂ superfÃÂcie dentinÃÂria dos espÃÂcimes empregando-se o cimento provisÃÂrio com eugenol Temp Bond ou o cimento sem eugenol Freegenol. ApÃÂs 7 (sete) dias em ÃÂgua destilada a 37ÃÂC, as restauraÃÂÃÂes provisÃÂrias e os resÃÂduos de cimento foram removidos com instrumento manual. Nos grupos-controle, nÃÂo foram empregadas restauraÃÂÃÂes provisÃÂrias. As superfÃÂcies dentinÃÂrias foram limpas com pasta de pedra-pomes e ÃÂgua e tratadas de acordo com o sistema adesivo empregado: condicionamento com ÃÂcido fosfÃÂrico a 37% e aplicaÃÂÃÂo do sistema adesivo Adper Single Bond 2 (SB2) ou aplicaÃÂÃÂo do sistema adesivo autocondicionante Adper Prompt (AP). Em seguida, blocos de resina composta (Filtek Z 250) foram fixados ao substrato dentinÃÂrio utilizando-se um cimento resinoso (RelyX ARC). AtravÃÂs de cortes seriados, foram obtidos corpos-de-prova em forma de palitos com ÃÂrea de interface adesiva de aproximadamente 0,9 mm2 que foram submetidos ao ensaio de microtraÃÂÃÂo em mÃÂquina universal de testes com velocidade de 0,5mm/min atÃÂ a ruptura. A resistÃÂncia adesiva foi expressa pela tensÃÂo de ruptura dos corpos-de-prova. Os modos de fratura das interfaces adesivas foram analisados por microscopia ÃÂptica digital e microscopia eletrÃÂnica de varredura. A presenÃÂa de resÃÂduos dos cimentos provisÃÂrios foi investigada por microscopia de forÃÂa atÃÂmica. Os resultados de resistÃÂncia adesiva foram submetidos ÃÂ anÃÂlise de variÃÂncia (ANOVA) de dois critÃÂrios e teste t-Student para detectar diferenÃÂas significativas entre os grupos. Observou-se uma reduÃÂÃÂo estatisticamente significativa da resistÃÂncia adesiva quando o cimento Temp Bond foi empregado em relaÃÂÃÂo aos grupos-controle, tanto com o sistema adesivo SB2 (p = 0,0331) quanto com o sistema AP (p = 0,0267). Os grupos em que o sistema SB2 foi utilizado apresentaram valores de resistÃÂncia adesiva estatisticamente superiores aos grupos com o sistema AP (p< 0,0001), independentemente do emprego ou nÃÂo de cimentos provisÃÂrios. A anÃÂlise dos modos de fratura mostrou uma maior ocorrÃÂncia de fraturas mistas (67%), sendo que nos grupos com o sistema de condicionamento ÃÂcido total a ocorrÃÂncia de fraturas adesivas na interface dentina-adesivo foi estatisticamente menor que nos grupos com o sistema autocondicionante (p = 0,0001). Com base nesses resultados, concluiu-se que resÃÂduos microscÃÂpicos dos dois cimentos provisÃÂrios permaneceram sobre a superfÃÂcie dentinÃÂria mesmo apÃÂs limpeza mecÃÂnica e tratamento com ÃÂcidos. PorÃÂm, apenas o cimento provisÃÂrio contendo eugenol reduziu significativamente a resistÃÂncia de uniÃÂo ÃÂ dentina das restauraÃÂÃÂes indiretas de resina, independentemente do sistema adesivo empregado.
|
142 |
Dureza da camada de adesivo e da camada híbrida e a sua relação com a resistência de união à dentina / Hardness of the adhesive layer and the hybrid layer and its relationship to bond strength to dentinPaula Mendes Acatauassú Nunes 02 September 2013 (has links)
Este estudo avaliou in vitro a dureza da camada de adesivo e da camada híbrida de uma interface entre resina composta e dentina humana por meio de ensaios de nanodureza (DUH). Foi avaliada a resistência de união por meio de testes de microcisalhamento (MC) com o objetivo de observar a relação desta resistência com a propriedade da dureza. Os fatores de variação compreendem quatro sistemas adesivos (Adper Scotchbond Multiuso, Adper Single Bond 2, Clearfil SE Bond e Single Bond Universal) e duas profundidades dentinárias (dentina rasa e dentina profunda). As unidades experimentais foram compostas por 144 fragmentos dentais obtidos da face vestibular de molares humanos, os quais foram distribuídos em 16 grupos, 8 grupos com n=6 para os ensaios de DUH e 8 grupos com n=12 para os ensaios de MC de forma que os quatro sistemas adesivos foram aplicados sobre fragmentos de dentina rasa e de dentina profunda. Após a confecção das restaurações em resina composta e 24h de armazenamento em estufa a 37°C, os ensaios de DUH foram realizados no ultramicrodurômetro DUH-211S (Shimadzu) com carga de 1mN/mseg. Os testes de MC foram realizados na máquina de ensaios universais Instron 5942(Instron Co) com velocidade de 1mm/min seguido da análise do padrão de fratura em microscópio digital. A análise estatística foi realizada por ANOVA (p<0,01%), Tukey e correlação de Pearson (p<0,05%). O sistema SB Universal (M=31,82±4,72) evidenciou os maiores valores de resistência de união e o Clearfil SE (M=26,75±3,73) os menores. O Single Bond 2 (M=28,83±4,07) e Scotchbond MP (M=28,53±4,61) não apresentaram diferenças entre si e obtiveram valores intermediários, não se diferenciando do maior e nem do menor valor. A resistência de união na dentina rasa (M=30,45±4,40) foi maior que em dentina profunda (M=27,52±4,01). Os sistemas SB Universal (M=22,57±2,42) e Scotchbond MP (M=22,13±2,89) não apresentaram diferença entre si e evidenciaram valores de dureza na camada de adesivo maiores que o Clearfil SE (M= 19,11±1,23). O sistema Single Bond 2 (M=20,11±1,49) apresentou valores intermediários de dureza e não foi diferente do maior e do menor valor. A camada híbrida em dentina rasa (M=38,23±3,08) apresentou maior dureza que a camada híbrida em dentina profunda (M=33,09±1,85). Pode-se concluir que tanto o sistema adesivo utilizado quanto a profundidade dentinária influenciaram nos resultados de resistência adesiva. A dureza da camada de adesivo varia conforme o sistema utilizado sendo que os adesivos SB Universal e o Scotchbond MP apresentaram os maiores valores de dureza. A dureza da camada híbrida foi influenciada pela profundidade dentinária do substrato. Foi observada uma correlação direta entre a dureza da camada de adesivo e a resistência adesiva. / This study evaluated in vitro the hardness of the adhesive layer and the hybrid layer interface between composite and human dentin using nanohardness test (DUH). Was evaluated the bond strength by microshear test (MC) in order to observe the relationship of this resistance with the hardness property. The variation factors consist of four adhesive systems (Adper Scotchbond Multi-Purpose, Adper Single Bond 2, Clearfil SE Bond and Single Bond Universal) and two dentin depths (superficial and deep dentin). The experimental units consisted of 144 dental fragments obtained from molars vestibular area, which were divided into 16 groups, 8 groups with n = 6 for DUH test and 8 groups with n = 12 for the MC test, so the four adhesive systems were applied on dentin fragments of superficial and deep dentin. After the construction of the composite resin restorations and 24h storage at 37 °C, DUH analysis were performed using a nanoindentation device DUH-211S (Shimadzu) with load of 1mN/mseg. The MC tests were performed in a universal testing machine Instron 5942 (Instron Co) with speed 1mm/min followed by analysis of the failure site in digital microscope. Statistical analysis was performed by ANOVA (p <0.01%), Tukey, and Pearson correlation (p <0.05%). The system SB Universal (M = 31.82 ± 4.72) showed higher values of bond strength and Clearfil SE (M = 26.75 ± 3.73) lower. The Single Bond 2 (M = 28.83 ± 4.07) and Scotchbond MP (M = 28.53 ± 4.61) did not differ among themselves and had intermediate values, not differentiating the largest and the smallest value. The bond strength of superficial dentin (M = 30.45 ± 4.40) was higher than in deep dentin (M = 27.52 ± 4.01.) Universal Systems SB (M = 22.57 ± 2.42) and Scotchbond MP (M = 22.13 ± 2.89) did not differ among themselves and showed hardness values in the adhesive layer higher than Clearfil SE (M = 19.11 ± 1.23.) The system Single Bond 2 (M = 20.11 ± 1.49) showed intermediate values of hardness and was not different from the largest and smallest value. The hybrid layer in superficial dentin (M = 38.23 ± 3.08) was harder than the hybrid layer in depth dentin (M = 33.09 ± 1.85.) It can be concluded that both the adhesive system used as the dentin depth influenced the bond strength. The hardness of the adhesive layer varies depending on the system used and the SB Universal adhesive and Scotchbond MP showed higher hardness values. The hardness of the hybrid layer was influenced by the depth of the dentin substrate. We observed a direct correlation between the hardness of the adhesive layer and the bond strength.
|
143 |
Efeito da técnica úmida simplificada de adesão com etanol na cimentação intraradicular de pinos de fibra / Push-out bond strength and SEM evaluation of new bonding approach into the root canalCarlos Augusto Ramos de Carvalho 28 June 2011 (has links)
Este estudo avaliou a resistência ao deslocamento vertical push-out de pinos de fibra de vidro cimentados à dentina intra-radicular utilizando uma resina fluida padrão como agente cimentante em combinação com um adesivo dentinário experimental e um adesivo disponível comercialmente. 20 pré-molares unirradiculares humanos foram previamente extraídos e tratados endodonticamente. Os espécimes foram divididos em quatro estratégias de união a dentina: Grupo 1 com adesivo experimental com etanol na proporção em volume 1:1 (resina/etanol) e Grupo 2 com adesivo experimental com etanol na proporção em volume 1:2(resina/etanol); adesivos experimentais aplicados de acordo com a técnica úmida de adesão simplificada com etanol, Grupo 3: One-Step Plus aplicado de acordo com a técnica úmida de adesão simplificada com etanol; Grupo 4: One-Step Plus aplicado seguindo as instruções do fabricante. Os espécimes foram seccionados em fatias de 1 mm de espessura e apos o teste push-out foi realizado. Espécimes representativos foram selecionados para exame ultra-estrutural. Não houve diferença estatística na resistência ao deslocamento push-out entre as estratégias testadas de adesão (p> 0,05). O padrão predominante de fratura foi entre os pinos de fibra e o agente cimentante. A partir deste estudo devemos considerar como promissora a técnica com etanol utilizada na cimentação de pinos no canal radicular devido aos possíveis benefícios das resinas altamente hidrófobas. Mais estudos são necessários para validar o uso da técnica úmida de adesão simplificada com etanol quando cimentados pinos de fibra. / This study evaluated the push-out bond strength of glass fiber posts adhesively bonded to intraradicular dentin using a standard unfilled resin as luting agent in combination with an experimental and a commercially available adhesive. Twenty extracted single-rooted human teeth were endodontically treated. Specimens were assigned to 4 dentin bonding strategies: Group 1 (co-monomers to ethanol on ratio 1:1) and Group 2 (co-monomers to ethanol on ratio 1:2): Experimental adhesives applied in accordance with the simplified ethanol-wet bonding technique; Group 3: One-Step Plus (OSP) applied in accordance with the simplified ethanol-wet bonding technique; Group 4: OSP applied following manufacturers instructions. Bonded specimens were sectioned in 1-mm-thick slices and the push-out test was performed. Representative specimens were selected for ultrastructural examination. No statistical differences in push-out bond strength were found among the tested bonding strategies (p>0.05). The major failure pattern was between the post and the luting cement. From this study the ethanol technique should be considered as a promising approach in the luting of fiber posts into the root canal due to the possible benefits of highly hydrophobic resins. Further studies are needed to validate the use of the ethanol-wet bonding technique when luting a fiber post.
|
144 |
Efeito de inibidores proteolíticos na adesão de dentina desmineralizada por cárie ou erosão / Effect of proteolytic inhibitors in carious and eroded dentin adhesionMarina Ciccone Giacomini 09 February 2015 (has links)
A longevidade da interação estabelecida entre a união do material restaurador e substrato tem sido o foco principal da Odontologia Adesiva. Se por um lado, a dentina é alterada por desafios como a erosão e a cárie dentária, por outro lado, tecnologias que atendam às condições distintas do substrato e que possibilitem união química tem sido desenvolvidas. O objetivo desde trabalho foi avaliar o desempenho de um sistema adesivo restaurador universal (modo convencional) na resistência de união (RU) à dentina em diferentes condições (artificialmente erodida ou cariada) e pré-tratadas com inibidores proteolíticos. Noventa molares hígidos foram selecionados e preparados, obtendo-se superfícies planas que foram tratadas com lixa 600 por 1 minuto. Os espécimes foram aleatoriamente divididos em três grupos iniciais, de acordo com o substrato: N- sem simulação de desafio ácido (mantidos em saliva artificial); ERO- simulação de erosão (3x5min/5dias com suco de laranja) e CA- simulação de cárie artificial (6h desmineralizante+ 18hremineralizante/ 5 dias + 48 remineralizante). Em seguida, cada um desses grupos foi redividido em três subgrupos, de acordo com o pré-tratamento da dentina: Atratado com água; CHX- tratado com clorexidina a 2%e E-64- tratado com o inibidor E-64 a 5 μM. No total, formaram-se, 9 grupos (n=10): N-A, N-CHX, N-E-64, ERO-A, ERO-CHX, ERO-E-64, CA-A, CA-CHX, CA-E-64. Todos os espécimes foram restaurados com adesivo Adper Single Bond Universal® e com resina composta Filtek Z250. Os dentes foram cortados para a obtenção dos palitos (área de 0,64mm2 aproximadamente), que foram submetidos ao ensaio de microtração em máquina de teste a 0,5mm/min em 7 dias e 6 meses. O modo de fratura foi classificado de acordo com a análise das interfaces com microscopia ótica 40X. Os dados foram submetidos ao teste de normalidade e homogeneidade e analisados por ANOVA a três critérios e teste de Tukey (p<0,05). Os resultados demonstraram que houve interação entre o substrato x tratamento (p=0,0011) e substrato x tempo (p=0,0003). A dentina alterada por erosão e cárie artificialmente contribuíram negativamente na RU do sistema adesivo. O uso de clorexidina afetou negativamente a RU em todas as condições testadas. O E-64 mostrou-se efetiva em manter a estabilidade da união aos 6 meses para os substratos alterados. O sistema adesivo universal apresenta-se promissor para ser utilizado na dentina alterada, mantendo a resistência de união ao longo do tempo. O uso de E-64 não comprometeu a união à dentina, ao contrário do impacto no uso da solução de clorexidina. / The longevity of the interaction established between restorative material and substrate has been the main focus of Adhesive Dentistry. Dentin is altered through challenges as dental erosion and caries and, on the other hand, technologies that attend for particular conditions of the substrate and favors for the chemical bonding has been developed. The aim of this study was to evaluate the performance of a universal adhesive system (etch-and-rinse mode) on bonding strength (BS) to dentin in different conditions (artificial caries or erosion) and pretreated with proteolytic inhibitors. Ninety molars were selected and prepared, obtaining flat surfaces treated with 600 sandspaper for 1 minute. The specimens were randomly divided into three groups according to the substrate: N- with no challenges (stored in artificial saliva), ERO-artificial erosion simulation (3x5min/5days with orange juice) and CA- artificial caries simulation (6h demineralizing+ 18h-remineralizing/ 5 days + 48 remineralizing). Then, each of these groups was redivided into three subgroups according to the pretreatment of dentin: A- treated with water; CHX-treated with 2% chlorhexidine and E-64- treated with 5 μM E-64 inhibitor. Therefore, they constituted 9 groups (n = 10): N-A, N-CHX, N-E-64, ERO-A, ERO-CHX, ERO-E-64, CA-A, CACHX, CA-E-64. All specimens were restored with Adper Single Bond ® Universal and composite resin Filtek Z250. The teeth were cut to obtain sticks (area of approximately 0.64 mm2), which were subjected to the microtensile bond test in the testing machine at 0.5 mm/min after 7 days and 6 months. The failure mode was classified according to the analysis of interfaces by optical microscopy 40X. Data was tested to verify normal distribution and homogeneity to be analyzed with three-way ANOVA and Tukey tests (p <0.05). Data revealed interaction between substrate x treatment (p=0.0011) and between substrate x time (p=0.0003). Dentin affected by artificial erosion and caries negatively contributed to the BS. The use of chlorhexidine negatively affected the RU for all tested conditions. E-64 showed to be effective to maintain the bonding stability to affected dentin for 6 months. The universal bonding system seems to be promissory to be employed to affected dentin, maintaining the BS overtime. The use of E-64 did not affect the bonding to dentin, controversial to the use of chlorhexidine.
|
145 |
Resistência da união da cimentação adesiva de pinos de fibra de vidro frente ao teste de remoção por extrusão / Push-out bond strength of adhesive luted glass fiber postsLuciana Mendonça da Silva 24 March 2009 (has links)
Este trabalho avaliou a resistência de união de pinos de fibra de vidro cimentados à dentina com o uso de um cimento resinoso convencional e um auto-adesivo. Trinta dentes bovinos unirradiculares tiveram as raízes 17mm a partir dos ápices. As raizes foram tratadas endodonticamente e divididas aleatoriamente em 3 grupos (n=10): G1- cimento resinoso convencional RelyX ARC + ScotchBond Multi Uso Plus (SBMP) fotoativado + pino de fibra de vidro; G2 RelyX ARC + SBMP quimicamente ativado + pino de fibra de vidro; G3 cimento resinoso auto-adesivo RelyX U100 + pino de fibra de vidro. Após a cimentação dos pinos, os espécimes foram armazenados por 24 horas em água destilada, à 37oC. As raízes foram cortadas sob irrigação constante para obter de 6 a 9 fatias de 1mm de espessura. O teste de resistência à extrusão foi realizado para medir a resistência adesiva nas fatias da região cervical, média e apical, a uma velocidade de 0,5mm/min. Todos os espécimes foram observados em microscópio ótico de luz para avaliar os tipos de falhas. Os valores foram submetidos à análise de variância a dois critérios (ANOVA) e teste de Tukey (p0,05). As médias gerais dos grupos 1, 2 e 3, respectivamente, (MPa) foram de 4,87 (±3,65); 5,89(±3,72); e 8,50(±4,52). Os valores de resistência adesiva regional nos terços cervical, médio e radicular, respectivamente, foram: G1- 5,26(±3,44); 5,11(±3,33); 5,01(±3,17); G2- 7,45(±3,82); 5,88(±2,50); 4,91(±2,74); G3- 10,11(±3,11); 9,12(±3,70); 4,99(±3,28). Os maiores valores de resistência adesiva foram encontrados com o cimento auto-adesivo. Ao avaliar os terços separadamente, os grupos 2 e 3 obtiveram comportamento semelhante nos terços cervical e médio. No terço apical, todos os grupos tiveram o mesmo comportamento. A resistência de união foi influenciada pelo tipo de cimento utilizado e região radicular, mas não foi alterada pela variação do modo de polimerização do sistema adesivo. / This work evaluated the bond strength of glass fiber posts to dentin using a conventional and a self-adhesive resin cement. Thirty bovine incisors had their roots sectioned 17mm from their apices, endodontically treated and assigned into 3 groups (n=10): group 1, conventional resin cement RelyX ARC + ScotchBond Multi Purpose Plus (SBMP) light activated + glass fiber post; Group 2, RelyX ARC+ SBMP chemically activated + glass fiber post; Group 3, self-adhesive resin cement RelyX U100 + glass fiber post. After luting, specimens were stored for 24 hours in distilled water at 37oC. Roots were sliced under water irrigation to obtain 1mm thick slices. Push-out test was performed on each slice with a universal testing machine with a crosshead speed of 0,5mm/min. All fractured specimens were observed using a light microscope to identify modes of failure. Values were submitted to two-way ANOVA and Tukeys test (p0,05). Mean values (MPa) and standard deviation for groups 1, 2 and 3 were, respectively: 4.87 (±3.65); 5.89(±3.72); e 8.50(±4.52). Regional bond strength values for the cervical, medium and apical were: G1- 5.26(±3.44); 5.11(±3.33); 5.01(±3.17); G2- 7.45(±3.82); 5.88(±2.50); 4.91(±2.74); G3- 10.11(±3.11); 9.12(±3.70); 4.99(±3.28). The highest bond strength values were obtained using the self-adhesive cement. Regional bond strengths were similar in the cervical and medium region in groups 2 and 3. All cements had the same performance on the apical region. Bond strength was influenced by the type of cement used and radicular region, but was not altered by the activation mode of the bonding system.
|
146 |
Resistência de união entre cimento resinoso auto-adesivo e dentina selada com adesivo auto condicionante / Bond strenght between self adhesive resin cement and sealed dentin with self etching adhesiveLeite, Murillo Martins 23 February 2017 (has links)
Submitted by Cássia Santos (cassia.bcufg@gmail.com) on 2017-03-09T17:27:02Z
No. of bitstreams: 2
Dissertação - Murillo Martins Leite - 2017.pdf: 2935464 bytes, checksum: c2e541fcfb0b7d14e4119dc3da509cac (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2017-03-10T10:54:28Z (GMT) No. of bitstreams: 2
Dissertação - Murillo Martins Leite - 2017.pdf: 2935464 bytes, checksum: c2e541fcfb0b7d14e4119dc3da509cac (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2017-03-10T10:54:28Z (GMT). No. of bitstreams: 2
Dissertação - Murillo Martins Leite - 2017.pdf: 2935464 bytes, checksum: c2e541fcfb0b7d14e4119dc3da509cac (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Previous issue date: 2017-02-23 / Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / The daily practice of dentists evolves when restorative techniques lead to higher success rates and long-lasting in treatments associated to less invasive procedures. In this context, self-etching adhesives, self-adhesive cements and immediate dentin sealing are examples of modern materials and technique with an uprising popularity among clinicians. The objective of this study was to evaluate the influence of different surface treatment on the sealed dentin with self-etching adhesive on bond strength to a self-adhesive resin. The coronary portions of 90 bovine teeth, included in epoxy resin, were worn out for dentin exposure. The sample was randomly subdivided in six groups. In group C (control) the dentin was kept "fresh" while immediate dentin sealing with Clearfil SE Bond (Kuraray) were performed in the others five groups. After 24 hours of storage, the sealed dentin of the samples received different surface treatments: P group (prophylaxis with pumice); PA group (prophylaxis followed by etching with phosphoric acid); PAS group (prophylaxis, phosphoric acid and silanization); PASC group (prophylaxis, phosphoric acid, silanization and bonding layer of adhesive Clearfil SE Bond) and PAU group [prophylaxis, phosphoric acid and a universal adhesive layer Single Bond Universal (3M ESPE)]. After these protocols, U200 self-adhesive cement (3M ESPE) cylinders were bonded in all six groups, forming an average of 15 sample units per group. The samples were submitted to microshear bond strength test at 0.5mm/min for two storage times: 24 hours (T1) e 3 months (T2). Statistical analysis was carried out using Kruskal-Wallis test, presenting a significant difference between RUM values (p=0.0018) among groups, for 24 hours of storage, and PASC group presented values significantly higher than all other groups. For 3 months of storage, there was no significant difference (p=0,223) between the groups. It is possible to conclude that immediate dentin sealing produced microshear bond strength values similar to control group (as recommended by manufacturer, without immediate sealing), except for the group that associated prophylaxis, phosphoric acid, silane and Clearfil SE Bond that was significantly higher in 24 hours tests, without significant changes with 3 months of storage. / A odontologia evolui a partir de tratamentos que ofereçam alto índice de sucesso em comunhão com simplicidade técnica e menor agressão biológica possível. Nesse contexto, adesivos auto condicionantes, cimentos auto-adesivos e o selamento imediato da dentina são exemplos de materiais e técnica que estão sendo atualmente difundidos. O objetivo deste trabalho foi avaliar a influência de diferentes tratamentos de superfície para a dentina selada, com adesivo auto condicionante, na resistência de união com cimento resinoso auto-adesivo. As porções coronárias de 90 dentes bovinos, incluídas em cilindros de resina epóxi, foram desgastadas superficialmente até a exposição da dentina. A amostra foi subdividida em seis grupos aleatoriamente. No grupo C (controle) a dentina foi mantida “fresca” enquanto que nos outros cinco grupos foi realizado o selamento imediato da dentina com Clearfil SE Bond (Kuraray). Após armazenamento por 24 horas, receberam diferentes tratamentos da superfície selada: Grupo P (profilaxia com pedra pomes); Grupo PA (profilaxia seguido da aplicação do ácido fosfórico); Grupo PAS (profilaxia, ácido fosfórico e silano); Grupo PASC (profilaxia, ácido fosfórico, silano e adesivo do Clearfil SE Bond) e grupo PAU [profilaxia, ácido fosfórico e Single Bond Universal (3M ESPE)]. Após a realização desses protocolos, foram unidos, em todos os seis grupos, cilindros do cimento auto-adesivo U200 (3M ESPE), formando uma média de 15 unidades amostrais por grupo, sendo assim submetidos ao teste de resistência de união ao microcisalhamento (RUM) à 0,5mm/min para dois tempos de armazenamento: 24 horas (T1) e 3 meses (T2). De acordo com o teste Kruskal-Wallis, para o tempo de 24 horas de armazenamento, houve diferença significante entre os valores de RUM (p=0,0018) para os diferentes protocolos com o grupo PASC apresentando valores significativamente maiores que os demais grupos. Já em relação ao tempo de 3 meses de armazenamento, não houve diferença significante (p=0,223) entre os grupos. É possível concluir que o selamento imediato da dentina produziu valores de resistência de união semelhantes ao grupo controle (sem selamento imediato), recomendado pelo fabricante, exceto para o grupo que associou profilaxia, ácido fosfórico, silano e Clearfil SE Bond que foi significativamente superior nos testes com 24 horas, porém não havendo alterações significativas com 3 meses de armazenamento.
|
147 |
Avaliação longitudinal da resistência de união de pinos de fibra de vidro à dentina cimentados com quatro agentes cimentantes por meio do teste de push-outRosalyn Chidiak Tawil 02 December 2008 (has links)
Avaliou-se a resistência de união do pino de fibra de vidro à dentina cimentado com quatro agentes cimentantes, por meio do teste push-out realizado após 24 horas e seis meses de armazenagem. Foram selecionados 80 dentes humanos uniradiculares, tratados endodonticamente e divididos aleatoriamente em quatro grupos (n=20), variando-se o tipo de cimento utilizado: grupo I: cimento de ionômero de vidro reforçado com resina (Fuji PlusTM, GC Corp., Tokyo, Japan); grupo II: cimento resinoso usando sistema adesivo convencional de 3 passos de aplicação (RelyX ARC + Scotchbond Multi-purpose, 3M ESPE, St Paul, MN, USA); grupo III: cimento resinoso usando sistema adesivo autocondicionante de 1 passo de aplicação (PanaviaTM F, Kuraray, Osaka, Japan); e grupo IV: cimento resinoso auto-adesivo (BisCemTM, Bisco Inc., Schaumburg, IL). Cada grupo foi subdividido em dois subgrupos (N=10) variando-se o tempo de armazenagem (24 horas e seis meses). O teste de push-out foi realizado com uma velocidade de 1,0 mm/min, e os resultados expressos em Mega Pascal (MPa). Após o teste de push-out, todos os espécimes foram observados em microscópio óptico de fluorescência (40x) e analisado o tipo de falha apresentado entre o complexo pino/cimento/dentina radicular. Os valores médios de resistência (MPa) foram submetidos ao teste ANOVA a dois critérios e de Tukey (p<0,005). A análise estatística mostrou: 1) Diferenças significativas na resistência de união entre os cimentos utilizados, sendo que a média total do cimento resinoso RelyXTM ARC + ScotchbondTM MultipurposeTM foi superior aos dos outros cimentos após 24 horas; 2) A resistência de união dos cimentos resinosos RelyXTM ARC + ScotchbondTM MultipurposeTM e PanaviaTM F foram superiores aos outros cimentos quando testados após seis meses de armazenagem e não houve diferença significativa entre eles; 3) Após seis meses de armazenagem, observou-se um aumento na resistência de união de todos os cimentos; 4) Na análise por terços, foi observado que tanto após 24 horas quanto após seis meses, o terço cervical teve uma maior resistência de união do que o terço médio e apical; 5) Foram observadas predominantemente falhas mistas, apresentado-se na maioria dos casos a combinação de falha adesiva na interface pino/cimento e na interface cimento/dentina para todos os grupos. Concluiu-se que a resistência de união aumentou após seis meses de armazenagem graças possivelmente à expansão higroscópica e aumento da retenção friccional. / The bond strength of a glass fiber post luted to dentin with four luting agents was evaluated using the push-out test, after 24-hours and six months of storage. Eighty human single-routed teeth was selected, endodontically treated and randomly divided into four groups (n=20), modifying the luting agent used: group I: resin modified glass-ionomer (Fuji PlusTM, GC Corp., Tokyo, Japan); group II: resin cement using total-etch, three step adhesive system (RelyX ARC + Scotchbond Multi-purpose, 3M ESPE, St Paul, MN, USA); group III: resin cement using self-etch one step adhesive system (PanaviaTM F, Kuraray, Osaka, Japan); and group IV: self-adhesive resin cement (BisCemTM, Bisco Inc., Schaumburg, IL). Each group was, then, subdivided into two subgroups (n=10) modifying the storage period (24-hours and six months). The push-out test was performed with a cross-speed of 1,0 mm/min, and the results expressed in Mega Pascal (MPa). After the test, all specimen interfaces were examined with the aid of a fluorescence optic microscope (40x) to dertemine the type of failure at the complex post/cement/dentin. The mean values of the bond strength (MPa) were analyzed with the two-way ANOVA and Tukey test (p<0,005). The statistical analysis showed: 1) Significant difference in the bond strength between the luting agents, in wich the mean total value of the resin cement RelyXTM ARC + ScotchbondTM MultipurposeTM was the highest after 24 hours; 2) The bond strength of the resin cement RelyXTM ARC + ScotchbondTM MultipurposeTM and PanaviaTM F were higher than the others luting agents when evaluated after six months, and there was no significant difference among both of them; 3) An increase in the bond strength of all luting agents after six months of storage in distilled water; 4) That the cervical third had a higher bond strength compared to the middle and apical thirds for all materials, during third analysis after 24-hours and six months of storage; 5) Predominantly, it was observed mixed failures, in the majority of the cases, with a combination of adhesive failure in the post/luting agent interface and in the luting agent/radicular dentin interface. Therefore, can be concluded that the bond strength of a glass fiber post luted to dentin with different luting agents can increase after six months of storage, possibly contributed by hygroscopic expansion and the increase of the frictional retention.
|
148 |
Efeito do condicionamento ácido e do envelhecimento na resistência da união adesiva de um adesivo universal ao esmalte dental / Effect of acid etching and aging on bond strength of an universal adhesive on dental enamelVincenzi, Bárbara 28 March 2018 (has links)
Submitted by Edineia Teixeira (edineia.teixeira@unioeste.br) on 2018-10-03T14:30:06Z
No. of bitstreams: 2
Bárbara_Vincenzi2018.pdf: 1279106 bytes, checksum: d44d41a7b8387c799cad466834f2786c (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-10-03T14:30:06Z (GMT). No. of bitstreams: 2
Bárbara_Vincenzi2018.pdf: 1279106 bytes, checksum: d44d41a7b8387c799cad466834f2786c (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Previous issue date: 2018-03-28 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Purpose: To evaluate the performance of an universal restorative adhesive system (total- and self-etching mode) on bond strength (BS) to the enamel immediately and after 12 months.
Materials and methods: Eleven human third molars were sectioned in half to obtain twenty-two samples. The proximal enamel surfaces were planned, polished and randomly divided into 2 groups according to the treatment, and these subdivided (2 groups) according to the storage time, making 4 groups (n = 11): CAI (Scotchbond Universal adhesive-SBU, with prior 37% phosphoric acid conditioning for 15 sec, analyzed immediately); CA12m (same treatment as CAI, analyzed after 12 months aging); SAI group (SBU without prior acid conditioning, analyzed immediately); SA12m (same treatment as SAI, analyzed after 12 months aging). All samples were restored with Scothbond Universal adhesive (SBU) and Filtek Z100 composite resin according to the manufacturer's instructions. The composite resin blocks were built up incrementally. The specimens were stored in deionized for 24 hours and sectioned in sticks (1.0 ± 0.2 mm area) and subjected to microtensile on test machine on 0.5mm/min immediately (24h) and after 12 months . Data were submitted to ANOVA two criteria (p <0.01) followed by the Tukey post-test (p<0.05).
Results: Enamel acid etching promoted a significant increase in RU values after immediate traction. However, after 12 months, RU values decreased significantly, with no statistical difference between the groups with and without acid conditioning.
Conclusions: Enamel conditioning increased the immediate bond strength of the universal adhesive, and aging after 12 months reduced it. / Objetivos: Avaliar o desempenho de um sistema adesivo restaurador universal (modo convencional e autocondicionante) na resistência de união (RU) ao esmalte em período imediato e após 12 meses.
Materiais e métodos: Onze terceiros molares humanos hígidos foram seccionados ao meio para obter vinte e duas amostras. As superfícies proximais do esmalte foram planificadas, polidas e aleatoriamente divididas em 2 grupos de acordo com o tratamento, e estes subdivididos (2 grupos) de acordo com o tempo de estocagem, perfazendo 4 grupos (n=11): CAI (adesivo Scotchbond Universal-SBU, prévio condicionamento com ácido fosfórico por 15 seg, análise imediata); CA12m (mesmo tratamento do CAI, análise após envelhecimento de 12 meses); SAI (adesivo SBU sem condicionamento ácido prévio, análise imediata); SA12m (mesmo tratamento do SAI, análise após 12 meses). Todas as amostras foram restauradas com o adesivo Scothbond Universal (SBU) e resina composta Filtek Z100 de acordo com as instruções do fabricante. Os blocos de resina composta foram construídos incrementalmente. Os espécimes foram armazenados em água destilada por 24h, e posteriormente seccionados em palitos (área 1,0 ± 0,2mm) que foram submetidos ao teste de microtração em máquina de teste a 0.5mm/min imediatamente (24h) e 12 meses após. Os dados foram submetidos a ANOVA dois critérios (p <0.01) seguido pelo pós-teste de Tukey (p<0,05).
Resultados: O condicionamento ácido do esmalte promoveu aumento significativo dos valores de RU após tração imediata. No entanto, após 12 meses, os valores de RU diminuíram significativamente, sem diferença estatística entre os grupos com e sem condicionamento ácido.
Conclusões: O condicionamento do esmalte aumentou a resistência de união adesiva do adesivo universal imediata, e o envelhecimento após 12 meses a reduziu.
|
149 |
Efeito da contaminação por primer e pelo excesso de água, álcool ou clorexidina nas propriedades mecânicas e cinética de conversão de sistemas adesivos convencionais / Effect of contamination by primer and the water, ethanol or chlorexidine excess on mechanical properties and real time conversion of conventional adhesives systemsHumel, Maria Malerba Colombi, 1983- 21 August 2018 (has links)
Orientador: Luís Alexandre Maffei Sartini Paulillo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-21T22:44:51Z (GMT). No. of bitstreams: 1
Humel_MariaMalerbaColombi_D.pdf: 11561780 bytes, checksum: 79e3ed8605dc03bf07a59b8bb75596c5 (MD5)
Previous issue date: 2013 / Resumo: Este estudo teve como objetivo avaliar a influência de diferentes concentrações destas soluções na resistência à flexão (FS), módulo de Elasticidade (E) e grau de conversão (DC) de sistemas adesivos convencionais, e ainda, sua influência na cinética (K) e taxa de conversão (RP). Para isso foram realizados dois trabalhos experimentais, sendo que no primeiro avaliaram-se as quantidades de primer nos adesivos, e no segundo trabalho avaliou-se a influência das soluções de enxague de cavidade, água, EtOH e CHX, quando em excesso, nos sistemas adesivos. Para se avaliar as diferentes concentrações do primer residual dois adesivos foram manipulados, M1 e M2 e testados com quatro concentrações de primer: 0, 5, 10 e 15%. Já para se avaliar o excesso de água, EtOH e CHX, dois adesivos foram testados: M1, adesivo manipulado, e o adesivo comercial SBMP; diluídos com 0, 2 e 9% para cada uma das soluções. Para se avaliar as propriedades mecânicas, nos dois estudos, foram preparadas amostras a partir de moldes de silicone em forma de barras (7 x 2 x 1mm) e após armazenamento por 24h, foram testadas em máquina de ensaio mecânico para o teste de FS a uma velocidade de 0,5 mm/min. DC foi mensurado utilizando Espectroscopia Transformada Infravermelha de Fourier (FTIR). Para cinética de conversão, a polimerização em cada diluição foi monitorada por FTIR pelo tempo de 60s, sendo que a conversão foi calculada a cada dois 2s de polimerização, avaliando-se também RP. No primeiro estudo, as diferentes concentrações da diluição com primer não mostrou diferença no teste de FS entre os adesivos testados, independente da concentração avaliada. Os dois adesivos testados apresentaram redução nos valores de DC com o aumento das quantidades de primer, sendo o adesivo M2 o mais susceptível às diluições. No segundo trabalho, para as diluições com água, EtOH, independente da quantidade testada, uma redução nas propriedades mecânicas e DC puderam ser observadas. As diluições em água e CHX alteraram mais as propriedades mecânicas quando comparadas as diluições com EtOH. Para K e RP com o aumento da concentração de primer residual todos adesivos apresentaram redução quando se avaliou os gráficos de conversão. Para as diluições em água, o aumento de sua concentração levou a queda progressiva na K e as diluições com CHX apresentaram menor influência na K, com redução apenas para 9% de diluição. Porém, para as diluições em EtOH houve aumento na K e RP especialmente para o adesivo SBMP. Assim, para o primeiro estudo, os resultados sugerem que as diferentes quantidades de primer usadas na diluição do adesivo não influenciam as propriedades mecânicas dos adesivos testados, porém, interferem na sua reação química de polimerização, uma vez que a velocidade reação foi reduzida (K e RP). Por outro lado, no segundo estudo, para as soluções residuais de água, EtOH e CHX, uma diminuição nas propriedades mecânicas dos adesivos ocorreu somente quando quantidades residuais de 9% foram simuladas. No entanto, pequenas quantidades de EtOH e CHX parecem não afetar as propriedades e velocidade de reação de polimerização dos adesivos / Abstract: The present study evaluates the influence of these solutions in different concentrations on flexural strength (FS), elastic modulus (E) and degree of conversion (DC) of conventional adhesives evaluating also the kinetic of conversion (K) and rate of polymerization (RP). Two distinct experiments were plotted, the first one evaluating the primer amount diluted in adhesives, and the second experiment evaluating rinse solutions amounts like water, ethanol and chlorexidine diluted in different adhesives. For different concentrations of primer solutions, two manipulated adhesives; M1 and M2 were tested at 0, 5, 10 and 15% of dilution. For different concentrations of water, ethanol (EtOH) and chlorexidine (CHX) dilutions, two adhesives were evaluated: M1, a manipulated adhesive, and the SBMP; diluted at 0, 2 and 9% of dilutions. Both studies, for mechanical properties, specimens were obtained by silicon mold bars (7 x 2 x 1mm), and after 24h, FS were performed at Mechanical Test Machine at cross speed of 0.5 mm/min. DC were measured with a Fourier Transformed Infrared Spectroscopy (FTIR). For K test, Infrared Spectroscopy monitored each 2 seconds of conversion for 60sec of polymerization, and the RP were evaluated. The first experiment, for different concentrations of primer dilutions, the FS for all adhesives tested was not affected by primer concentrations. All adhesives tested showed a decrease for DC as increased the primer dilution, with M2 presenting as the most sensitive for primer concentration. For second experiment, for all concentrations dilution of water, EtOH and CHX, a decrease on mechanical properties and DC was noted. Water and chlorexidine seems to affect more mechanical properties when compared to EtOH results. For K and RP results, increasing primer concentration, all adhesives presented a decrease of conversion and RP. For water dilutions, increasing water concentrations on tested adhesives, a progressive decrease could be noted on K graphics. CHX dilutions presented less influence on K, with decreasing RP and K only with 9% dilution. Although, EtOH dilutions presented an improve K as the RP, especially to SBMP adhesive. The results suggested that mechanical properties were not affected regardless of the primer amount diluted on adhesives, interfering only on chemistry of polymer reaction, once reaction speedy were affected (K and RP). However, for second experiment, a decrease on mechanical properties of adhesive solutions could be noted only when extreme amounts of residual solution where diluted. Notwithstanding, at lowest concentrations, EtOH and CHX seems not interfere on K and RP of adhesives / Doutorado / Dentística / Doutora em Clínica Odontológica
|
150 |
Avaliação da influência de métodos de descontaminação após contaminação com sangue em diferentes momentos do processo adesivo / Evaluation of the influence of decontamination methods after contamination with blood in different moments during the dentin adhesive processDamé, Josiane Luzia Dias 23 June 2006 (has links)
Made available in DSpace on 2014-08-20T14:30:09Z (GMT). No. of bitstreams: 1
Dissertacao_joziane_luzia_dias_dame.pdf: 564053 bytes, checksum: dd7e96465f7bec29457bc90946463293 (MD5)
Previous issue date: 2006-06-23 / Contamination while restoration procedures are carried out is mentioned in literature as a very frequent event, besides that, there are only a few papers which value this contamination influence in adhesion and possible decontamination methods to be carried out under such an occurrence. So, the aim of this study was to evaluate the influence of decontamination protocols upon dye leakage and push-out bond strength of a dentin adhesive system. It was used a hundred thirty five bovine incisors, which had their labial surface ground to obtain a flat dentine surface where standardized cylindrical cavities were made and they were divided in three groups: A) control without contamination (n = 15); B) contamination prior to the adhesive light activation (Adper Single Bond 2 3M ESPE) (n = 60) and C) contamination after the light activation (n = 60). After the contamination the cavities were divided (n = 15)
according to the protocol used: 1) absorbent paper; 2) water; 3) conditioning with phosphoric acid or 4) sodium hypochlorite at 10%. The cavities were restored with the composite (Filtek Z250 3M ESPE), applied to only one increment. After 24
hours the restorations were polished and the specimens were subjected to thermal cycling (500 cycles/5o C a 55oC/30s). The exposure of the stained margins was done through the use of 2% methylene blue dye (pH = 7.0) and digital measurement of the restorations. The specimens cavity floor was ground, exposing the restoration, and they were submitted to the extrusion test (push out) in a universal testing machine. To statistics analysis it was used ANOVA according to two criteria (moment and protocol) and Tukey s test. In the marginal sealing evaluation there was significant
statistics in the moment factor (p<0.001) and also in the interaction moment x protocol (p<0.008). The percentage average of stained margins found after light activation was statistically higher than the ones found prior to the light activation (p<0.001). In group B the conditioning protocol showed a percentage average of stained margins statistically higher than the water group (p<0.003), and the paper
and hypochlorite groups demonstrated intermediate values. Comparing to group C protocols, it was not detected significant differences. Relating to the extrusion resistance, only the moment factor was statistically significant (p<0.001), while group B values were statistically higher (p<0.05) than the group C ones (5.32+3.03 and 3.4+1.92 MPa respectively). All protocols demonstrated resistance values similar to the control values. Higher resistance values were related to lower values of stained margins. It was concluded that blood contamination after light activation of the adhesive system had an adverse effect in the sealing ability of composite restorations and the different decontamination protocols generally produced similar results / A contaminação durante a realização de procedimentos restauradores é citada na literatura como um evento muito freqüente, apesar disso, poucos são os trabalhos que avaliam a influência desta contaminação na adesão e possíveis métodos de descontaminação a serem realizados frente a sua ocorrência. Assim, este trabalho teve como objetivo avaliar a influência dos métodos de descontaminação no selamento marginal e na resistência à extrusão de um sistema adesivo dentinário. Foram utilizados 135 incisivos bovinos, que tiveram a face vestibular desgastada expondo-se dentina, onde foram confeccionadas cavidades circulares padronizadas.
Estas foram distribuídas em três grupos: A) controle, sem contaminação (n = 15); B) contaminação previamente à fotoativação do adesivo (Adper Single Bond 2 - 3M ESPE) (n = 60) e C) contaminação após a fotoativação (n = 60). Após a
contaminação as cavidades foram divididas (n = 15) de acordo com o método utilizado: 1) papel absorvente; 2) água; 3) condicionamento com ácido fosfórico ou 4) hipoclorito de sódio a 10%. As cavidades foram restauradas com o compósito (Filtek Z250 - 3M ESPE), aplicando-se um único incremento. Após 24h as restaurações foram polidas e os espécimes submetidos à ciclagem térmica (500 ciclos/5°C a 55°C/30s). O selamento marginal foi avaliado utilizando-se o corante azul de
metileno a 2% (pH = 7,0) seguido da digitalização das restaurações. Os espécimes foram desgastados pela face lingual expondo a restauração, e submetidos ao ensaio de extrusão (push out) em uma máquina de ensaios mecânicos. Para a análise estatística foram utilizados ANOVA segundo dois critérios (momento x método) e Teste de Tukey. Na avaliação do selamento marginal houve significância estatística para o fator momento (p<0,001) e também para interação momento X método (p=0,008). O nível médio de margens coradas encontradas após a fotoativação foi estatisticamente superior ao encontrado previamente a fotoativação (p<0,001).
Dentro do Grupo B o método condicionamento demonstrou uma média de margens coradas estatisticamente superior ao grupo água (p<0,003), e os grupos papel e hipoclorito demonstraram valores intermediários. Para as comparações entre métodos dentro do Grupo C não foram detectadas diferenças significativas. Em relação à resistência à extrusão, apenas o fator momento demonstrou ser estatisticamente significante (p<0,001), sendo os valores do Grupo B estatisticamente superiores (p<0,05) aos do Grupo C (5,32±3,03 e 3,4±1,92 MPa respectivamente). Todos os métodos demonstraram valores de resistência similares ao controle. Maiores valores de resistência foram relacionados a menores valores de margens coradas. Concluiu-se que a contaminação com sangue após a fotoativação do sistema adesivo teve um efeito adverso na capacidade de selamento de restaurações de compósito e os diferentes métodos de descontaminação geralmente produziram resultados similares
|
Page generated in 0.1602 seconds