• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 15
  • 1
  • Tagged with
  • 16
  • 16
  • 14
  • 13
  • 4
  • 4
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação clínica, histológica e imunológica de enxertos ósseos alógenos fresco-congelados utilizados como técnica na preservação de rebordo alveolar pós-extração / Preservation of alveolar bone in extraction sockets using fresh-frozen bone allograft: a clinical, histological and immunological study

Figueira, Eduardo Aleixo 05 September 2011 (has links)
O osso alógeno fresco-congelado (FFBA, do inglês fresh-frozen bone allograft) é uma alternativa para os procedimentos cirúrgicos de enxerto ósseo, principalmente na preparação do rebordo alveolar para a instalação de implantes osseointegráveis. No entanto, existem alguns paradigmas que envolvem a relação entre resposta do sistema imunológico à aloantígenos presentes no enxerto e o seu comportamento clínico. Procurando entender essa relação, o FFBA foi avaliado como enxerto para preservar o rebordo alveolar pós-extração. Os resultados mostraram que embora tenha ocorrido uma redução estatisticamente significante na altura, espessura e volume do rebordo entre a avaliação inicial e final, essa redução não foi clinicamente significante, permitindo a instalação de implantes osseointegráveis. Em adição, as análises histológicas sugerem um bom comportamento do enxerto, com ausência de reação do tipo corpo estranho e formação de novo osso em todos os sítios analisados. Ao analisar o comportamento da resposta imune, os resultados mostraram que a injeção intradérmica de aloantígenos presentes no FFBA, não induziu uma reação de hipersensibilidade tardia nos pacientes após 4 meses do enxerto. Além disso, os monócitos do sangue periférico (PBMCs) dos pacientes não proliferaram frente aos aloantígenos in vitro. No entanto, os dados também demonstraram que os aloantígenos aumentam a produção de IL-2 e IFN-, mas não alteram a produção de IL-4 e IL-10, por PBMCs dos pacientes. Ao avaliar a relação entre a produção dessas citocinas e o comportamento clínico do enxerto, os dados mostram que existe uma correlação estatisticamente significante entre a produção de IL-2 in vitro e a redução (em %) da altura do rebordo alveolar, embora essa redução não tenha sido clinicamente significante. De fato, a presença de aloantígenos no FFBA não é suficiente para sua contraindicação como material de enxertia. / The fresh-frozen bone allograft (FFBA) is an alternative to surgical procedures of bone grafts, mainly in the preservation of alveolar ridge prior the installation of osseointegrated implants. However there are paradigms that surround the relation between immune response to alloantigens present inside the graft and the clinical response of the graft. An attempt to understand this relationship, the FFBA was evaluated as a graft to preserve the alveolar ridge post-extraction. The results show a statistically significant reduction in height, thickness and volume of the ridge between the initial and final examination, however this reduction was not clinically significant. The ridge preservation allowed implant installation and osseointegration. In addition, histologic analysis suggests a good performance of the graft with no foreign body reaction and formation of new bone at all sites. In analyzing the behavior immune response, the results showed that stimulation with alloantigens present in bone allograft induced no delayed hypersensitivity reaction in vivo. Additionally, periphery blood mononuclear cells (PBMC) from patients no proliferate in response to alloantigens in vitro. However, the data also demonstrated that the alloantigens increase IL-2 and IFN- production, but no IL-4 and IL-10 production, by PBMCs from patients. When evaluate the relation between the cytokines production and clinical parameters, the results demonstrate that there statistically significant correlation between IL-2 production in vitro and ridge height changes (%), although this clinical parameter is not clinically significant. In fact, the alloantigens in FFBA are not sufficient for its contraindications as grafting material.
2

Avaliação clínica, histológica e imunológica de enxertos ósseos alógenos fresco-congelados utilizados como técnica na preservação de rebordo alveolar pós-extração / Preservation of alveolar bone in extraction sockets using fresh-frozen bone allograft: a clinical, histological and immunological study

Eduardo Aleixo Figueira 05 September 2011 (has links)
O osso alógeno fresco-congelado (FFBA, do inglês fresh-frozen bone allograft) é uma alternativa para os procedimentos cirúrgicos de enxerto ósseo, principalmente na preparação do rebordo alveolar para a instalação de implantes osseointegráveis. No entanto, existem alguns paradigmas que envolvem a relação entre resposta do sistema imunológico à aloantígenos presentes no enxerto e o seu comportamento clínico. Procurando entender essa relação, o FFBA foi avaliado como enxerto para preservar o rebordo alveolar pós-extração. Os resultados mostraram que embora tenha ocorrido uma redução estatisticamente significante na altura, espessura e volume do rebordo entre a avaliação inicial e final, essa redução não foi clinicamente significante, permitindo a instalação de implantes osseointegráveis. Em adição, as análises histológicas sugerem um bom comportamento do enxerto, com ausência de reação do tipo corpo estranho e formação de novo osso em todos os sítios analisados. Ao analisar o comportamento da resposta imune, os resultados mostraram que a injeção intradérmica de aloantígenos presentes no FFBA, não induziu uma reação de hipersensibilidade tardia nos pacientes após 4 meses do enxerto. Além disso, os monócitos do sangue periférico (PBMCs) dos pacientes não proliferaram frente aos aloantígenos in vitro. No entanto, os dados também demonstraram que os aloantígenos aumentam a produção de IL-2 e IFN-, mas não alteram a produção de IL-4 e IL-10, por PBMCs dos pacientes. Ao avaliar a relação entre a produção dessas citocinas e o comportamento clínico do enxerto, os dados mostram que existe uma correlação estatisticamente significante entre a produção de IL-2 in vitro e a redução (em %) da altura do rebordo alveolar, embora essa redução não tenha sido clinicamente significante. De fato, a presença de aloantígenos no FFBA não é suficiente para sua contraindicação como material de enxertia. / The fresh-frozen bone allograft (FFBA) is an alternative to surgical procedures of bone grafts, mainly in the preservation of alveolar ridge prior the installation of osseointegrated implants. However there are paradigms that surround the relation between immune response to alloantigens present inside the graft and the clinical response of the graft. An attempt to understand this relationship, the FFBA was evaluated as a graft to preserve the alveolar ridge post-extraction. The results show a statistically significant reduction in height, thickness and volume of the ridge between the initial and final examination, however this reduction was not clinically significant. The ridge preservation allowed implant installation and osseointegration. In addition, histologic analysis suggests a good performance of the graft with no foreign body reaction and formation of new bone at all sites. In analyzing the behavior immune response, the results showed that stimulation with alloantigens present in bone allograft induced no delayed hypersensitivity reaction in vivo. Additionally, periphery blood mononuclear cells (PBMC) from patients no proliferate in response to alloantigens in vitro. However, the data also demonstrated that the alloantigens increase IL-2 and IFN- production, but no IL-4 and IL-10 production, by PBMCs from patients. When evaluate the relation between the cytokines production and clinical parameters, the results demonstrate that there statistically significant correlation between IL-2 production in vitro and ridge height changes (%), although this clinical parameter is not clinically significant. In fact, the alloantigens in FFBA are not sufficient for its contraindications as grafting material.
3

Utilização de enxerto autógeno e substitutos ósseos no levantamento do seio maxilar : análise volumétrica /

Menezes, Juliana Dreyer da Silva January 2018 (has links)
Orientador: Eduardo Hochuli Vieira / Resumo: A proposta deste estudo foi avaliar o processo de manutenção de volume dos biomateriais vidro bioativo e beta tricálcio-fosfato (β-TCP) associados ou não ao osso autógeno na técnica de levantamento do seio maxilar de humanos. Treze seios maxilares foram enxertados com β-TCP, sete com β-TCP associado ao osso autógeno, onze com vidro bioativo, nove com vidro bioativo associado ao osso autógeno e onze com osso autógeno (Grupo Controle). Após 7 a 14 dias, tomografias computadorizadas de feixe cônico (TCFC) foram solicitados para mensurar o volume inicial do enxerto (T1). Decorridos 6 meses de reparação óssea, novos exames tomográficos foram realizados para avaliar o volume final (T2) e verificar as alterações volumétricas dos materiais. Após a análise dos resultados, considerando as alterações volumétricas em um período de 6 meses, evidenciou-se um comportamento semelhante entre o enxerto autógeno e os substitutos ósseos, não sendo observada diferença estatisticamente significante entre os materiais analisados. / Abstract: The purpose of this study was to evaluate the process of bone maintenance and remodeling with the use of bioactive glass and beta-tricalcium phosphate (β-TCP) associated or not with autogenous bone in the human maxillary sinus technique. Thirteen maxillary sinuses were grafted with β-TCP, seven with β-TCP associated with autogenous bone, eleven with bioactive glass, eleven with bioactive glass associated with autogenous bone and eleven with autogenous bone (Control Group). After 7 to 14 days, computed tomography (CBCT) were requested to measure the initial graft volume (T1). After 6 months of bone repair, new tomographic examination were performed to evaluate the final volume (T2) and to verify the volumetric changes of the materials. After analyzing the results, considering the volumetric changes over a 6-month period, a similar behavior was observed between the autogenous graft and the bone substitutes, and no statistically significant difference was observed between the analyzed materials. / Doutor
4

Avaliação retrospectiva de implantes com conexões protéticas do tipo cone morse e hexágono externo instalados em seios maxilares previamente enxertados e em osso nativo /

Barros Filho, Luiz Antônio Borelli. January 2020 (has links)
Orientador: Elcio Marcantonio Junior / Resumo: O objetivo desse estudo foi de avaliar retrospectivamente a taxa de sobrevivência de implantes com diferentes tipos de conexão protética instalados na região posterior de maxila, em osso nativo ou em seios previamente enxertados com diferentes biomateriais. Foram avaliados 310 implantes que foram instalados em 103 pacientes sendo que 87 implantes foram instalados associados a seios maxilares enxertados (56 cone morse - CM e 31 hexágonos externos-HE) em 37 pacientes e 223 implantes foram instalados em áreas de osso nativo (112 CM e 111 HE) em 76 pacientes. Foram realizadas análises clínicas peri-implantares: 1)Sangramento à sondagem; 2)Profundidade de sondagem; 3)Nível da margem periimplantar; 4)Presença de mobilidade ou supuração e análise do nível ósseo radiográfico. Dois implantes foram perdidos, um CM em osso nativo e um HE em seio enxertado, o que forneceu uma taxa de sobrevivência de 99.35 %. Foi verificado que os implantes do tipo CM apresentaram menores profundidades de sondagem e maior nível ósseo periimplantar em comparação aos implantes HE tanto em área enxertada como em área de osso nativo (p<0.05). Não houve diferenças estatisticamente significativas entre os implantes instalados em áreas de osso nativo e enxertado em nenhum parâmetro avaliado. Implantes HE instalados em áreas de osso nativo apresentaram maiores taxas de peri-implantite. Pode-se concluir que implantes de plataforma do tipo CM reduzem a perda óssea periimplantar, porém a instalação de implantes em ... (Resumo completo, clicar acesso eletrônico abaixo) / Doutor
5

Estudo comparativo entre o tecido ósseo criopreservado e o conservado em glicerol a 98% / Comparative analysis between bone tissue cryopreservation and glycerol 98% preservation methods

Giovani, Arlete Mazzini Miranda 09 December 2005 (has links)
O Banco de Tecidos do Instituto de Ortopedia e Traumatologia do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo está desenvolvendo uma linha de estudos experimentais com o intuito de apresentar novos métodos de armazenamento de aloenxertos. Este estudo tem como objetivo comparar o método da criopreservação (- 80° C) com o da conservação em glicerol a 98% em temperatura ambiente. Foram analisadas tanto a capacidade de inibição de crescimento bacteriano e fúngico quanto às eventuais alterações histológicas. Para isso, foram estudadas 30 amostras de tecido ósseo trabecular coletadas de 10 pacientes submetidos à artroplastia total do quadril. Estas amostras foram divididas em três grupos de 10 espécimes, a saber: grupo controle, grupo criopreservado e grupo conservado em glicerol a 98% à temperatura ambiente. O período de armazenamento das amostras foi de um ano. Os resultados foram analisados estatisticamente pelo método de McNemar, com índice de significância de 0,10. No que diz respeito à preservação da matriz óssea, não houve variações significativas nos dois grupos estudados em relação ao grupo controle. Não ocorreu crescimento bacteriano ou de fungos nas amostras armazenadas durante um ano em glicerol a 98%. Por ser extremamente reduzido em relação à criopreservação, o custo do método da conservação em glicerol a 98% o indica para uso em Bancos de Tecidos de pequena monta. Contudo, são ainda necessários posteriores estudos sobre as propriedades biomecânicas, remoção do glicerol do tecido ósseo e o processo de integração biológica dos mesmos com o receptor. / The Tissue Bank of Instituto de Ortopedia e Traumatologia do Hospital das Clínicas da Universidade de São Paulo is developing a line of experimental studies with the intention to present new methods of allografts storage. This study has the objective to compare the method of cryopreservation (-80 ºC) with glycerol 98% preservation at room temperature. It even analyses, in such way, the inhibition capacity of bacterial and fungal growth and any eventual histological changes. For this, 30 samples of trabecular bone tissue have been collected from 10 patients submitted to total hip arthroplasty. These samples were separated in three groups of 10 specimens, as following: a control group, a cryopreserved group and a glycerol 98% preserved group at room temperature. They were stored during a period of one year. The results were analysed by the McNemar statistic method, with a significance of 0,10. Concerning to bone matrix, no significant changes occurred to the two studied groups compared to the control group. Bacterial and fungal growth do not occurred in the stored samples for one year in glycerol 98%. For being extremely reduced when compared with cryopreservation method, the preservation cost in glycerol 98% indicates its use on small sum tissue banks. However, posterior studies about biomechanical properties, glycerol removal of bone tissue and their biological process of integration with the receiver are necessary.
6

"Estudo da utilização clínica das proteínas ósseas morfogenéticas em cirurgia buco-maxilo-facial no Brasil" / Study of the use of Bone Morphogenetic Proteins in Cranio-maxillo- facial Surgery in Brazil.

Moreira, Alessandra Arnaud 06 December 2004 (has links)
A recuperação de partes deficientes do corpo humano por substitutos funcionais, tem suscitado questionamentos por parte de profissionais cirurgiões e pesquisadores da área de cirurgia e traumatologia Bucomaxilofacial. Na tentativa de recuperar o contorno anatômico natural e restaurar a função de áreas com deficiência de tecido ósseo, optou-se inicialmente pela utilização de enxertos ósseos autógenos. Apesar de suas inúmeras vantagens, o uso de enxertos autógenos na reconstrução da face apresenta certos inconvenientes, como a necessidade de hospitalização, intervenção em outra área do organismo, morbidade da área doadora, maior período de convalescença, susceptibilidade a infecções, e ainda, uma possível reabsorção progressiva e constante. Um questionamento ainda maior gira em torno das cirurgias para enxerto ósseo na face já que os ossos da face são curtos e não justifica a morbidade de uma outra região do organismo para suprir sua necessidade. Na tentativa de substituir o uso de enxertos autógenos, cirurgiões começaram a optar por materiais sintéticos ou similares orgânicos, associadas com o uso das proteínas ósseas morfogenéticas, que são fatores de crescimento responsáveis pela indução da formação óssea no organismo humano desde sua fase fetal até a idade madura. A proposta deste estudo é fazer uma avaliação sobre o conhecimento e o uso clínico pelos cirurgiões buco-maxilo-faciais, no Brasil, de proteínas ósseas morfogenéticas no auxílio à reparos de defeitos ósseos da face. / The use of alloplastic materials for bone replacement has been extensively debated lately by surgeons and researchers in the Oral and Maxillofacial field. In the attempt to reconstruct bone defects anatomically and functionally autogenous bone grafts have been the preferred option. Although being considered the gold standard in craniofacial reconstruction, there are some inconveniences in the use of bone autografts. Among them the need of hospitalization, the need of a donor site usually in a different area than the bone defect, donor area morbidity, longer recovery time, increased risk of infection, and the possibility of bone resorption over time. When the face is operated the use of autogenous bone is even more questionable. Usually small amounts of bone grafts are necessary in the face, and might not justify the morbidity of the donor site. In an attempt to avoid the use of bone autografts, allografts and alloplastic materials have been advertised, in association with bone morphogenetic proteins. These proteins are growth factors involved in the osteogenesis in humans from the fetus up to the adult age. The aim of this study is to evaluate the knowledge and the clinical use of bone morphogenetic proteins in the repair of facial bone defects by Brazilian Oral and Maxillofacial surgeons.
7

Alorreatividade dos enxertos ósseos homólogos na reconstrução alveolar em humanos / Allorreactivity of fresh-frozen boné graft in human ridge augmentation

Mayara Perez Braga 17 February 2014 (has links)
Enxerto ósseo homólogo é utilizado independentemente da compatibilidade HLA entre doador e receptor ou uso de drogas imunossupressoras. Considerando o volume de transplantes ósseos realizados no Brasil e o possível efeito deletério da sensibilização HLA para o transplante de órgãos sólidos, este estudo tem como objetivo avaliar a alorreatividade do enxerto ósseo homólogo fresco-congelado utilizado na reconstrução alveolar com finalidade de reabilitação oral com prótese sobre implantes. Anticorpos anti-HLA e anti-MICA foram monitorados através do teste Labscreen Mixed, nos intervalos 0, 7, 30, 90 e 180 pós transplante ósseo em 15 pacientes (6 homens e 9 mulheres, idade média 58,1, DP=10,1) que estavam em tratamento no Instituto de Odontologia da Pontifícia Universidade Católica do Rio de Janeiro. Caso resultado do teste Mixed fosse positivo (Razão de fundo normatizado, NBG>4,5) o teste Labscreen Single (tecnologia antígeno único por pérola, SABA) era realizado para verificar se os anticorpos anti-HLA eram específicos ao doador. Nenhum paciente relatou transplante prévio, 4 relataram transfusão prévia e todas as mulheres relataram gravidez. Dez pacientes não apresentaram reação positiva no dia 0 sendo considerados não sensibilizados previamente (NSP); destes, 6 pacientes permaneceram sem nenhuma evidência de sensibilização, 2 pacientes apresentaram reação positiva para Classe I e II; 2 para Classe I apenas; e 2 para MICA, sendo considerados sensibilizados pelo enxerto ósseo oral. Dois pacientes apresentaram aumento de Intensidade Média de Fluorescência (&#916;MFI>1000) de anticorpos específicos ao doador para Classe I e Classe II, e 2 somente para Classe II, demonstrando uma reação específica ao doador. Os resultados sugerem uma alorreatividade HLA oscilatória ao enxerto ósseo homólogo em reconstruções alveolares, confirmada pela formação de anticorpos anti-HLA específicos ao doador em 4 pacientes (27%) da amostra. / Bone allografts are used without HLA donor-receptor compatibility or imunosupressor therapy. Taking in consideration the amount of bone graft procedures performed in Brazil and the possible deleterious effect of HLA sensitization in solid organ transplantation, the aim of this study was to evaluate fresh-freeze bone graft alorreactivity used in ridge augmentation surgery before oral rehabilitation with implants supported bridges. Anti-HLA and anti-MICA antibodies were evaluated by Labscreen Mixed test, at 0, 7, 30, 90 e 180 days after bone transplantation in 15 patients (6 men e 9 women, mean age 58,1, SD=10,1) treated at the Dental Institute of the Rio de Janeiro Catholic University. If the mixed test (Normalized Background Ratio, NBG>4,5) was positive, donor specificity was evaluated by Labscreen Single test (Single Antigen Bead Assay technology, SABA). None of patients had previous transplant history, 4 had transfusion history, and all women had pregnancy history. Ten patients did not have positive results at baseline and were considered not sensitized previously; 6 patients of them did not have any sensitization evidence during 6 month follow up, 2 patients had positive reaction for anti-HLA Class I and II; 2 were positive for anti-HLA Class I only; e 2 patients were positive for anti-MICA, and were considered sensitized by oral bone graft. Two patients had increased values of Median Fluorescence Intensity (&#916;MFI>1000) of anti-HLA donor specific antibodies Class I and II, 2 for Class II only, showing a donor specific alorreactivity. The results sugest an oscilatory HLA reactivity, confirmed by the donor specific antibodies formation on 4 patients (27%) of this study.
8

Alorreatividade dos enxertos ósseos homólogos na reconstrução alveolar em humanos / Allorreactivity of fresh-frozen boné graft in human ridge augmentation

Mayara Perez Braga 17 February 2014 (has links)
Enxerto ósseo homólogo é utilizado independentemente da compatibilidade HLA entre doador e receptor ou uso de drogas imunossupressoras. Considerando o volume de transplantes ósseos realizados no Brasil e o possível efeito deletério da sensibilização HLA para o transplante de órgãos sólidos, este estudo tem como objetivo avaliar a alorreatividade do enxerto ósseo homólogo fresco-congelado utilizado na reconstrução alveolar com finalidade de reabilitação oral com prótese sobre implantes. Anticorpos anti-HLA e anti-MICA foram monitorados através do teste Labscreen Mixed, nos intervalos 0, 7, 30, 90 e 180 pós transplante ósseo em 15 pacientes (6 homens e 9 mulheres, idade média 58,1, DP=10,1) que estavam em tratamento no Instituto de Odontologia da Pontifícia Universidade Católica do Rio de Janeiro. Caso resultado do teste Mixed fosse positivo (Razão de fundo normatizado, NBG>4,5) o teste Labscreen Single (tecnologia antígeno único por pérola, SABA) era realizado para verificar se os anticorpos anti-HLA eram específicos ao doador. Nenhum paciente relatou transplante prévio, 4 relataram transfusão prévia e todas as mulheres relataram gravidez. Dez pacientes não apresentaram reação positiva no dia 0 sendo considerados não sensibilizados previamente (NSP); destes, 6 pacientes permaneceram sem nenhuma evidência de sensibilização, 2 pacientes apresentaram reação positiva para Classe I e II; 2 para Classe I apenas; e 2 para MICA, sendo considerados sensibilizados pelo enxerto ósseo oral. Dois pacientes apresentaram aumento de Intensidade Média de Fluorescência (&#916;MFI>1000) de anticorpos específicos ao doador para Classe I e Classe II, e 2 somente para Classe II, demonstrando uma reação específica ao doador. Os resultados sugerem uma alorreatividade HLA oscilatória ao enxerto ósseo homólogo em reconstruções alveolares, confirmada pela formação de anticorpos anti-HLA específicos ao doador em 4 pacientes (27%) da amostra. / Bone allografts are used without HLA donor-receptor compatibility or imunosupressor therapy. Taking in consideration the amount of bone graft procedures performed in Brazil and the possible deleterious effect of HLA sensitization in solid organ transplantation, the aim of this study was to evaluate fresh-freeze bone graft alorreactivity used in ridge augmentation surgery before oral rehabilitation with implants supported bridges. Anti-HLA and anti-MICA antibodies were evaluated by Labscreen Mixed test, at 0, 7, 30, 90 e 180 days after bone transplantation in 15 patients (6 men e 9 women, mean age 58,1, SD=10,1) treated at the Dental Institute of the Rio de Janeiro Catholic University. If the mixed test (Normalized Background Ratio, NBG>4,5) was positive, donor specificity was evaluated by Labscreen Single test (Single Antigen Bead Assay technology, SABA). None of patients had previous transplant history, 4 had transfusion history, and all women had pregnancy history. Ten patients did not have positive results at baseline and were considered not sensitized previously; 6 patients of them did not have any sensitization evidence during 6 month follow up, 2 patients had positive reaction for anti-HLA Class I and II; 2 were positive for anti-HLA Class I only; e 2 patients were positive for anti-MICA, and were considered sensitized by oral bone graft. Two patients had increased values of Median Fluorescence Intensity (&#916;MFI>1000) of anti-HLA donor specific antibodies Class I and II, 2 for Class II only, showing a donor specific alorreactivity. The results sugest an oscilatory HLA reactivity, confirmed by the donor specific antibodies formation on 4 patients (27%) of this study.
9

Avalia??o microsc?pica dos fragmentos ?sseos obtidos por diferentes m?todos de osteotomia e de irriga??o em aloenxertos irradiados e congelados de coelho / Microscopic evaluation of bone fragments obtained from different methods of osteotomy and irrigation of irradiated and frozen rabbit allografts

Leite, Pedro Henrique de Alencar e Silva 31 August 2009 (has links)
Made available in DSpace on 2014-12-17T15:30:54Z (GMT). No. of bitstreams: 1 PedroHASL_Dissret.pdf: 4618668 bytes, checksum: 5bca73a0220258bdbd17a75573adb995 (MD5) Previous issue date: 2009-08-31 / Oral and facial bone defects can undertake appearance, psychosocial well-being and stomathognatic function of its patients. Over the yerars several strategies for bone defect regeneration have arised to treat these pathologies, among them the use of frozen and irradiated bone allograft. Manipulation of bone grafts it s not determined yet, and several osteotomy alternatives can be observed. The present work evaluated with a microscope the bone fragments obtained from different osteotomy methods and irrigation on rings and blocks allografts irradiated and frozen at 80? negative in a rabbit model. The study is experimental in vitro and it sample was an adult male New Zealand rabbit. The animal was sacrificed to obtain long bones, that were submitted to freezing at 80? negative and irradiated with Cobalt- 60. Then the long bones were sectioned into 24 bone pieces, divided into 4 groups: G1 (n=06) osteotomy was performed with bur No. 6 forming rings with 5 mm thickness with high-speed handpiece with manual irrigation; G2 (n=06) osteotomy was performed with bur No. 6 forming rings with 5 mm thick with surgical motor with a manual irrigation rotation 1500 rpm; GA (n=06), osteotomy with trephine using manual irrigation with saline; and GB (n=06), osteotomy with trephine using saline from peristaltic pumps of surgical motor. Five bone pieces of each group were prepared for analysis on light microscopy (LM) and one on electronic scan electronic microscopy (SEM). On the SEM analysis edges surface, presence of microcracks and Smear Layer were evaluated. Analyzing osteotomy technics on SEM was observed: increased presence of microcracks cutting with high speed; increased presence of areas covered by Smear Layer when cutting with motor implant. The irrigation analysis with SEM was observed: that the presence of microcracks does not depend on the type of irrigation; on manual irrigation, there was greater discrepancy between the cutting lines. The descriptive analysis of the osteotomy and irrigation process on LM showed: histological analysis showing the bony margins with clear tissue changed layer, composed of blackened tissue of charred appearance near to the cortical bone; on the edges of the bony part, bone fragments that were displaced during the bone cut and bone irregularities were observed. After analysis of results we can conclude: that there was greater regularity of the bone cut using high-speed handpiece than using motor implant; the cut with trephine using saline irrigated from peristaltic pumps of surgical motor showed greater homogeneity when compared with manual irrigation; charred tissue was found in all obtained bone samples, whit no significant statistically difference on the proportion of carbonization of the two analysed technics / Os defeitos ?sseos bucais e faciais comprometem a apar?ncia, o bem estar psicossocial e a fun??o estomatogn?tica dos seus portadores. Diante da necessidade de tratamento dessas patologias, surgiram, com o decorrer do tempo, diversas estrat?gias para a regenera??o de defeitos ?sseos, dentre elas o uso de aloenxerto ?sseo congelado e irradiado. A manipula??o dos enxertos ?sseos ainda n?o est? determinada, podendo-se observar v?rias alternativas de osteotomia. Este trabalho avaliou microscopicamente os fragmentos ?sseos obtidos por diferentes m?todos de osteotomia e de irriga??o sobre an?is e blocos de aloenxertos irradiados e congelados a 80?C negativos de coelho. O estudo ? do tipo Experimental in vitro e teve como amostra 01 coelho, adulto, da ra?a New Zealand. O animal foi sacrificado para obten??o de ossos longos, os quais foram congelados a 80? negativos e irradiados com Cobalto-60. Em seguida, os ossos foram seccionados em 24 pe?as ?sseas, divididos em quatros grupos: G1 (n=06) foi realizado a osteotomia com broca esf?rica n? 6 formando an?is com 5 mm de espessura com caneta de alta rota??o com irriga??o manual; G2 (n=06) foi realizado a osteotomia com broca esf?rica n? 6 formando an?is com 5 mm de espessura com motor cir?rgico com irriga??o manual a uma rota??o de 1500 rpm; GA (n=06), osteotomia com trefina usando irriga??o manual com soro fisiol?gico; e GB (n=06), osteotomia com trefina usando soro fisiol?gico proveniente de bombas perist?lticas do motor cir?rgico. De cada grupo, cinco pe?as ?sseas foram destinadas ? an?lise em Microscopia de Luz (ML) e uma analisada por Microscopia Eletr?nica de Varredura (MEV). A an?lise por ML levou em considera??o a presen?a de tecido carbonizado. Na an?lise por MEV levou em considera??o: superf?cie das bordas; presen?a de microfissuras e Smear Layer. Ao analisar a t?cnica de osteotomia utilizando MEV observa-se: maior presen?a de microfissuras ao corte com alta rota??o; maior presen?a de ?reas cobertas por uma camada de smear layer em cortes com motor de implante. Na analise da irriga??o com MEV observou-se que: a presen?a de microfissuras n?o depende do tipo de irriga??o; na irriga??o manual, verificou-se uma discrep?ncia maior entre as linhas de corte. Ao avaliar descritivamente o processo de osteotomia e irriga??o na ML, verificou-se que: na an?lise histol?gica as margens ?sseas apresentavam uma evidente camada alterada de tecido, composta por um tecido enegrecido de aspecto carbonizado, pr?ximo ao osso cortical; nas margens da pe?a ?ssea foram observados fragmentos ?sseos deslocados durante o corte ?sseo e irregularidades ?sseas. Ap?s an?lise dos resultados, pode-se concluir que: houve maior regularidade do corte ?sseo utilizando caneta de alta rota??o do que motor de implante; o corte com trefina usando irriga??o com bombas perist?lticas do motor de implante se mostrou mais homog?nea quando comparada ? t?cnica com irriga??o manual; tecido carbonizado foi encontrado em todos os esp?cimes ?sseos obtidos, sem diferen?a estatisticamente significativa na propor??o de carboniza??o nas duas t?cnicas de irriga??o estudadas
10

"Estudo da utilização clínica das proteínas ósseas morfogenéticas em cirurgia buco-maxilo-facial no Brasil" / Study of the use of Bone Morphogenetic Proteins in Cranio-maxillo- facial Surgery in Brazil.

Alessandra Arnaud Moreira 06 December 2004 (has links)
A recuperação de partes deficientes do corpo humano por substitutos funcionais, tem suscitado questionamentos por parte de profissionais cirurgiões e pesquisadores da área de cirurgia e traumatologia Bucomaxilofacial. Na tentativa de recuperar o contorno anatômico natural e restaurar a função de áreas com deficiência de tecido ósseo, optou-se inicialmente pela utilização de enxertos ósseos autógenos. Apesar de suas inúmeras vantagens, o uso de enxertos autógenos na reconstrução da face apresenta certos inconvenientes, como a necessidade de hospitalização, intervenção em outra área do organismo, morbidade da área doadora, maior período de convalescença, susceptibilidade a infecções, e ainda, uma possível reabsorção progressiva e constante. Um questionamento ainda maior gira em torno das cirurgias para enxerto ósseo na face já que os ossos da face são curtos e não justifica a morbidade de uma outra região do organismo para suprir sua necessidade. Na tentativa de substituir o uso de enxertos autógenos, cirurgiões começaram a optar por materiais sintéticos ou similares orgânicos, associadas com o uso das proteínas ósseas morfogenéticas, que são fatores de crescimento responsáveis pela indução da formação óssea no organismo humano desde sua fase fetal até a idade madura. A proposta deste estudo é fazer uma avaliação sobre o conhecimento e o uso clínico pelos cirurgiões buco-maxilo-faciais, no Brasil, de proteínas ósseas morfogenéticas no auxílio à reparos de defeitos ósseos da face. / The use of alloplastic materials for bone replacement has been extensively debated lately by surgeons and researchers in the Oral and Maxillofacial field. In the attempt to reconstruct bone defects anatomically and functionally autogenous bone grafts have been the preferred option. Although being considered the gold standard in craniofacial reconstruction, there are some inconveniences in the use of bone autografts. Among them the need of hospitalization, the need of a donor site usually in a different area than the bone defect, donor area morbidity, longer recovery time, increased risk of infection, and the possibility of bone resorption over time. When the face is operated the use of autogenous bone is even more questionable. Usually small amounts of bone grafts are necessary in the face, and might not justify the morbidity of the donor site. In an attempt to avoid the use of bone autografts, allografts and alloplastic materials have been advertised, in association with bone morphogenetic proteins. These proteins are growth factors involved in the osteogenesis in humans from the fetus up to the adult age. The aim of this study is to evaluate the knowledge and the clinical use of bone morphogenetic proteins in the repair of facial bone defects by Brazilian Oral and Maxillofacial surgeons.

Page generated in 0.1049 seconds