Desenvolvimento e propriedades mecânicas da placa óssea bloqueada em formato T / Development and mechanical properties of a locking T-plate

Mesquita, Luciane dos Reis [UNESP] 03 July 2015 (has links) (PDF)
Made available in DSpace on 2016-07-01T13:10:25Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-07-03. Added 1 bitstream(s) on 2016-07-01T13:14:09Z : No. of bitstreams: 1 000864064_20170803.pdf: 144226 bytes, checksum: 6db435f9c14d2caa7d0fbe3b85819efe (MD5) Bitstreams deleted on 2017-08-07T14:09:15Z: 000864064_20170803.pdf,. Added 1 bitstream(s) on 2017-08-07T14:10:18Z : No. of bitstreams: 1 000864064.pdf: 839342 bytes, checksum: 9a89eab66a535ba6ef6d68f443f111d4 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo do estudo foi desenvolver uma placa óssea bloqueada em formato de T, com o intuito de ser utilizada em fraturas distais de rádio, e avaliar a resistência da montagem, por meio de ensaios mecânicos. A placa de 2,7 mm foi confeccionada em titânio, contendo eixo com três orifícios para parafusos bloqueados e um orifício para compressão dinâmica, e uma cabeça com dois orifícios para parafusos bloqueados. A cabeça da placa possuía uma chanfradura localizada na porção médio-distal e a extremidade proximal da haste da placa apresentava formato afunilado. Para os ensaios mecânicos foram usados 40 corpos de prova sintéticos em formato de T e 20 placas em T. A placa óssea foi posicionada sobre os corpos de prova, com a falha óssea segmentar de 2 mm localizada entre a cabeça e a haste da placa. Para a determinação das cargas para os ensaios de fadiga, seis montagens foram testadas até a falha, sendo três em flexão engastada e três em compressão. Para o ensaio de fadiga foram utilizadas 14 montagens, sendo sete testadas em compressão axial e sete em flexão engastada. Em ambos os ensaios foram observados valores mais altos, em todas as variáveis avaliadas, na configuração sob carga axial do que na flexão engastada. Além disso, no ensaio em fadiga em compressão axial as montagens suportaram um maior número de ciclos. Foi possível concluir que pelos testes mecânicos, o modelo oferece suficiente estabilidade para resistir as cargas axiais no tratamento de fratura radial distal / The aim of this study was to develop a locked T-plate to be used in distal radial fractures and evaluate the mechanical properties. A titanium 2.7 mm T-plate was designed with a shaft containing three locked screw holes and one dynamic compression hole, and a head with two locked screw holes. The head of the plate had an indentation and shaft had tapered-shaped end. Forty polyurethane blocks having a T-shaped and 20 titanium T-plates were used for mechanical testing. The bone plate was positioned over the polyurethane blocks with 2 mm fracture gap between the head and shaft of the plate. Six bone-plate constructs were tested until failure, three in axial compression and three in cantilever bending, to determine the loads for fatigue testing. Fourteen bone-plate constructs were tested for failure in fatigue, seven in axial compression and seven in cantilever bending. Fatigue failure was defined as polyurethane block breakage or pullout of the screws in the polyurethane block. Tests were discontinued after one million cycles if the construct had not already failed. In both static and fatigue testing, higher values of axial compression test than cantilever bending test were observed for all variables. Moreover, the constructs under fatigue axial compression test supported a larger number of cycles to failure. The locking Tplate tested has biomechanical properties that may offer sufficient stability to resist axial loads in the treatment of a distal radius fracture
22

Comparação biomecânica entre CRIF e placa de reconstrução utilizadas para estabilização de fraturas distais de fêmur de cães / Biomechanical comparison of CRIF and reconstruction plate for stabilization of distal femur fractures in dogs

Fernanda Paes 25 October 2016 (has links)
O presente estudo objetivou comparar biomecanicamente, por meio do ensaio de compressão excêntrica, a resistência dos implantes Clamp and Rod Internal Fixation (CRIF) 5,0 mm versus placa de reconstrução 3,5 mm na fixação de fratura distais de fêmur de cão. Tais implantes foram subdividos em dois grupos, denominados grupo CRIF (GC) e grupo placa (GC). Foram utilizados 22 fêmures de 10 cadáveres de cão entre 2 e 7 anos de idade e peso corporal entre 20 e 40 kg, que foram distribuídos aleatoriamente a serem testados ambos os implantes em cada um dos membros dos pares. Para realização dos testes, foi simulado uma fratura distal nos corpos de prova, através de uma osteotomia de até 0,5 cm, realizada por meio de serra oscilatória, imediatamente proximal ao início da tróclea. Os implantes foram fixados segundo os padrões AOSIF, lateralmente ao fêmur, sendo utilizados três parafusos distais e cinco proximais ao foco de fratura. Foi utilizado o programa de computador PMI para calcular o ponto máximo de resistência antes da falha e avaliadas as variáveis força máxima, deformação máxima real, rigidez, força intermediária e deformação intermediária real. Não foram encontradas diferenças estatisticamente significativas entre os GC e GP quantos as variáveis avaliadas / This study aims to compare the biomechanical properties, through eccentric compression test, of the resistance of the 5.0 mm Clamp and Rod Internal Fixation Implants (CRIF) and 3.5 mm reconstruction plate in fixing dog femur distal fracture. Such implants were subdivided into two groups, called CRIF Group (CG) and plate group (CG). It was used 22 femurs from 11 dog cadavers with age between 2 and 7 years old and body weight between 20 and 40 kg, which was randomly assigned to test both implants in each member of the pair. A distal fracture in the specimens with a gap of 0.5 cm osteotomy, it was simulated to perform the test, performed by the oscillating saw, just proximal to the beginning of the trochlea. Bound the distance from the gap to the distal femur limit was equivalent to the distance between the femoral condyles. The implants were fixed by the standards AO / SIF, laterally to the femur, being used three distal screws and five proximal to the fracture site. The bone was placed longitudinally, and the femoral neck coupled to a concave surface simulating an acetabular device. PMI computer program was used to calculate the maximum point of resistance before failure and evaluated the variables maximum strength, real maximum deformation, stiffness, intermediate strength and real intermediate deformation. No statistically significant differences were found between the GC and GP as the variables evaluated
23

Análise mecânica e fotoelástica de quatro diferentes métodos de fixação em fraturas de corpo mandibular / Mechanical and photoelastic analysis of four different fixation methods for mandibular body fractures

Rodrigues, Danillo Costa, 1981- 24 August 2018 (has links)
Orientador: Roger William Fernandes Moreira / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-24T15:32:49Z (GMT). No. of bitstreams: 1 Rodrigues_DanilloCosta_D.pdf: 786712 bytes, checksum: 20e5c6c3c2775a5b2c547eae752381d0 (MD5) Previous issue date: 2014 / Resumo: O propósito do presente estudo foi avaliar comparativamente, através de teste de carregamento linear e análise fotoelástica, quatro métodos de fixação em fraturas simuladas em corpo de hemimandíbulas de poliuretano e resina fotoelástica. O trabalho foi dividido em quatro grupos: O grupo I, foi fixado com duas placas do sistema 2,0mm, uma na zona de tensão e outra na zona de compressão mandibular. No grupo II, utilizou-se uma placa do sistema 2,0mm na zona central da mandíbula e uma barra de Erich na zona dentada. O grupo III, foi fixado com uma placa do sistema 2,4mm na zona de compressão e uma barra de Erich na zona dentada. E no grupo IV, foi empregada uma placa do sistema 2,0mm na zona de tensão e uma placa do sistema 2,4mm na zona de compressão. Os métodos de fixação utilizados em cada grupo foram semelhantes em ambos os testes. Testes de carregamento linear foram realizados por meio da máquina para ensaio universal mecânica Instron®. Os valores foram analisados pelo teste de Shapiro-Wilk. Em seguida, foi aplicada a Análise de Variância (ANOVA), Kruskal-Wallis e posteriormente, o teste de Tukey e Mann-Whitney com correção de Bonferroni. Para a análise do teste fotoelástico, as hemimandíbulas em resina fotoelástica foram fotografadas quando a máquina de ensaio registrou o deslocamento final de 3mm e as franjas formadas no substrato foram avaliadas de forma qualitativa. Os resultados dos testes mecânicos indicaram que o grupo II apresentou menor resistência, seguido dos grupos I, IV e III. O teste fotoelástico confirmou a maior formação de tensão no grupo de menor resistência mecânica. Dessa forma concluiu-se que em fraturas lineares de corpo de mandíbula a utilização de placa do sistema 2,4mm apresentou maior resistência e que o emprego de apenas uma placa do sistema 2,0mm na zona central apresentou maior tensão / Abstract: The purpose of this study was to evaluate comparatively through linear load testing and photoelastic analysis, four methods of fixation in simulated fractures on polyurethane hemimandibles body and photoelastic resin. The study was divided into four groups: Group I was fixed with two plates of 2.0 mm system, one in the tension zone and another in compression zone. In Group II, it was used a 2.0 mm plate in the neutral zone and an Erich bar. Group III was fixed with a 2.4 mm plate in the compression zone and an Erich bar. The group IV was employed a 2.0 mm plate in tension zone and a 2.4 mm plate in the compression zone. The fixation methods used in each group were similar in both tests. Linear load testing was performed using an Instron® mechanical universal testing machine. After the tests, the values were analyzed by the Shapiro-Wilk test, Analysis of Variance (ANOVA), Kruskal -Wallis test and subsequently the Tukey test, and Mann-Whitney test with Bonferroni correction. For the analysis of photoelastic test, the hemimandibles were photographed in photoelastic resin when the testing machine recorded the final displacement of 3mm and the fringes formed on the substrate were evaluated qualitatively. The results of mechanical tests indicated that the group II had lower resistance, followed by the groups I, III and IV. The photoelastic test confirmed the increased formation of tension in the group of lower mechanical strength. Thus, it was concluded that in linear mandibular body fracture using the system board 2.4 mm presented more resistance and the use of only one 2.0 mm plante in the central area of the mandible showed higher tension / Doutorado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Doutor em Clínica Odontológica
24

Estudo comparativo da resistência mecânica cíclica e linear entre placas pré-dobradas e dobradas manualmente para avanço maxilar em cirurgia ortognática / Comparative study of cyclic and linear mechanical resistance of prebent and manually bent plates used for maxillary advancement in orthognathic surgery

Moura, Andrezza Lauria de, 1982- 25 August 2018 (has links)
Orientador: Roger William Fernandes Moreira / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-25T11:10:00Z (GMT). No. of bitstreams: 1 Moura_AndrezzaLauriade_D.pdf: 2051584 bytes, checksum: 4113d876cae0533f95488619a05aa704 (MD5) Previous issue date: 2014 / Resumo: O propósito no estudo foi avaliar comparativamente, através de teste de carregamento linear e cíclico, placas pré-dobradas e dobradas manualmente para avanço maxilar em cirurgia ortognática. Os grupos foram divididos em: Grupo I com placas pré-dobradas para avanço maxilar de 5mm, fixadas em blocos de poliuretano para o teste linear e blocos de alumínio para o teste cíclico; e grupo II, com placas dobradas manualmente simulando avanço maxilar de 5mm, fixadas em blocos de poliuretano e alumínio. Os testes de carregamento linear foram realizados com 8 amostras em cada grupo e com auxílio da máquina para ensaio universal mecânica Instron® 4411 até a falha do material. Já o teste cíclico foi realizado com 5 amostras em cada grupo através de uma máquina para ensaio universal Instron® E3000 e foram submetidas à carga de 12N a 120N, frequência de 3 Hz até a fratura da placa ou parafuso e com o número máximo de 500.000 ciclos. As médias e desvio padrão foram avaliadas através dos testes t-Student e Mann-Whitney em nível de significância de 5% para o teste linear e medianas através do teste Mann-Whitney para o teste cíclico. Os resultados do teste mecânico linear mostraram que não houve diferença estatística entre os grupos de placas pré-dobradas e dobradas manualmente, quando comparados em relação a carga de pico (p=0.09) e deslocamento de pico (p=0.63). Já o teste cíclico apresentou diferença estatística entre os grupos quanto ao número de ciclos, onde o grupo de placas pré-dobradas atingiu o limite de 500.000 ciclos sem fratura e o grupo de placas dobradas manualmente fraturaram em uma média 94.737 ciclos (p=0.008). A resistência mecânica in vitro entre os grupos de placas pré-dobradas e as dobradas manualmente não alterou com a confecção de dobras no teste de carregamento linear, porém, a confecção das mesmas pode ter criado microfraturas e fragilizações que, com o teste de ciclagem, causaram fratura prematura das placas com dobras manuais / Abstract: The purpose of the study was to comparatively evaluate, through linear load testing and cyclic loading test, prebent plates and plates bent manually to maxillary advancement in orthognathic surgery. The groups were divided into Group I with prebent plates for 5mm maxillary advancement, fixed in polyurethane blocks for linear test and aluminum blocks for cyclic test; and group II, with eight plates bent manually for 5mm maxillary advancement, fixed in polyurethane and aluminum blocks. Linear loading tests were performed with eight samples in each group through a mechanical universal testing machine Instron ® 4411, until failure of the material. The cyclic tests were performed with five samples in each group through a mechanical universal testing machine Instron ® E3000, where the samples were subjected to load of 12N to 120N and frequency of 3 Hz until plate or screw fracture, whit maximum number of 500,000 cycles. Means and standard deviations were evaluated by applying the Student t test and Mann-Whitney test at a significance level of 5% for linear loading and medians by Mann-Whitney test for cyclic loading. The results of linear mechanical testing showed no statistical difference between the groups pre-folded cards and folded manually compared peak load (p = 0.09) and peak displacement (p = 0.63). The cyclic test showed statistical difference between the groups, where the group of prebent plates reached the limit of 500,000 cycles without fracture and the group of manual bent plates fractured at an average of 94.737 cycles (p=0.008). The mechanical resistance in vitro among groups of prebent plates and plates bent manually does not change with the confection of bends in the linear loading test; however, the bends may have created microfractures and embrittlements that with the cyclic test, caused premature fracture of the plates / Doutorado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Doutora em Clínica Odontológica
25

Avaliação mecânica in vitro e análise fractográfica de duas marcas comerciais nacionais de sistema de fixação 2,0mm com travamento de parafusos em fraturas simuladas de corpo mandibular / Mechanical and fractographic analysis of two national brands of 2.0mm locking fixation systems in simulated mandibular body fracture

Correia Medeiros, Raquel, 1986- 23 August 2018 (has links)
Orientador: Roger William Fernandes Moreira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-23T02:59:43Z (GMT). No. of bitstreams: 1 CorreiaMedeiros_Raquel_M.pdf: 1506622 bytes, checksum: 7e7760f3ed374300679a2cb781f5ca71 (MD5) Previous issue date: 2013 / Resumo: Este trabalho teve como objetivo de avaliar comparativamente a resistência de duas marcas de sistema de fixação de 2,0 mm com sistema de travamento de parafusos em hemimandíbulas de alumínio com fratura simulada de corpo mandibular. E também, realizar a análise fractográfica das placas utilizadas no estudo acima, através de Microscopia Eletrônica de Varredura (MEV). Quatro hemimandíbulas em alumínio com seccionamento linear simulando uma fratura de corpo mandibular foram utilizadas como substrato, fixadas de acordo com duas técnicas de fixação de duas marcas nacionais Tóride® (Tóride Indústria e Comércio Ltda. - Mogi Mirim, São Paulo - Brasil) e Traumec® (Traumec - Tecnologia e Implantes Ortopédicos Imp. e Exp. Ltda.- Rio Claro, São Paulo- Brasil) e divididas em dois grupos. O grupo I foi fixado com uma placa de quatros furos, com quatro parafusos de 6 mm na zona de tensão e uma placa de 4 furos, com 4 parafusos de 10 mm na zona de compressão e o grupo II foi fixado com uma placa de 4 furos com 4 parafusos de 6 mm na zona neutra. Para cada grupo foram utilizadas cinco amostras de cada marca comercial. As hemimandíbulas foram submetidas a testes de carregamento linear vertical por uma unidade de testes mecânicos Instron 4411(Instron Corp, Norwood, MA) para registro da carga de pico e da carga nos deslocamentos de 3 mm, 5 mm e 7 mm. As médias e o desvio padrão foram avaliados aplicando-se a Análise de Variância em nível de significância de 5%. Após os testes mecânicos, não houve diferença estatisticamente significante entre as marcas, tanto no grupo I quanto no grupo II, em relação às cargas suportadas no deslocamento de 3 mm e 5mm, nem entre as cargas de pico, havendo diferença apenas no deslocamento de 7 mm. De uma maneira geral, as placas Tóride® suportaram uma carga maior nos dois grupos. A superfície de fratura analisada no MEV apontou para uma fratura do tipo dúctil, normalmente encontrada em corpos de ensaio de tração de materiais dúcteis, como o titânio. Não foram observados em nenhuma superfície de fratura quaisquer indícios de falha por alteração na estrutura ou na composição do material / Abstract: This study aimed to comparatively evaluate the resistance of two brands of rigid fixation system with 2,0 mm locking system in hemimandibles of aluminum with simulated fracture of the mandibular body. Also, perform fractographic analysis of the same, by Scanning Electron Microscopy (SEM). Four hemimandible of aluminum with a sectioning linear simulating fracture of mandibular body were used as substrate and fixed according to two techniques for two national brands Tóride® (Tóride Indústria e Comércio Ltda. - Mogi Mirim, São Paulo - Brazil) and Traumec® (Traumec - Orthopedic Implants and Technology Imp. e Exp Ltda. - Rio Claro, São Paulo, Brazil). The techniques were: two 4- hole locking miniplate applied at the superior and inferior borders and one 4-hole locking miniplate applied in neutral zone. The samples was subjected to linear vertical loading in the canine region in an mechanical testing unit Instron 4411 (Instron Corporation, Norwood, MA) and the peak load and load displacement in 3 mm, 5 mm and 7 mm were recorded. Averages and standard deviations were evaluated by applying the analysis of variance at a significance level of 5%.After mechanical testing, there was no statistically significant difference between the brands, both in group I and group II, in relation to the load supported in the displacement of 3 mm and 5 mm, or between peak loads. The only difference between the brands, for both groups, was the load in the displacement of 7 mm. In general, the plates Toride supported a greater load in both groups. The fracture surface examined under SEM indicated a ductile fracture, usually found in bodies testing of ductile materials such as titanium. Were not observed, in any fracture surface, any evidence of failure by altering the structure or composition of the material / Mestrado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Mestra em Clínica Odontológica
26

Análise da resistência mecânica e fractográfica de placas de titânio do sistema 1,5mm e dois métodos de fixação em fraturas simuladas em corpo de hemimandíbula de alumínio / Mechanical and fractographic analysis of 1,5mm titanium platesin two methods of fixation in simulated body fractures of aluminum hemimandibles

Rodrigues, Danillo Costa, 1981- 23 August 2018 (has links)
Orientador: Roger William Fernandes Moreira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-23T17:35:55Z (GMT). No. of bitstreams: 1 Rodrigues_DanilloCosta_M.pdf: 1685806 bytes, checksum: 0e90fd8fb32a562bcf7161f1f78bfab7 (MD5) Previous issue date: 2013 / Resumo: O presente estudo teve como propósito analisar a resistência mecânica de duas marcas de fixação do sistema 1,5mm através de teste mecânico de carregamento linear em dois métodos de fixação em modelos de hemimandíbulas de alumínio com fraturas simuladas e realizar análise fractográfica. Foi realizada a confecção de quatro estruturas de alumínio semelhantes a hemimandíbula, sendo utilizada duas hemimandíbulas para cada grupo de estudo. As mesmas foram fixadas com placas e parafusos das marcas Tóride® e Traumec®. No grupo I foi empregada uma placa reta de titânio de quatro furos na zona de compressão e outra na zona de tensão mandíbular; e no grupo II, foi empregada apenas uma placa reta de quatro furos na zona neutra. Para os testes mecânicos, foi utilizada a máquina para ensaio universal mecânica Instron® modelo 4411 até ocorrer a falha total do sistema de fixação (fratura da placa). Em seguida, as amostras foram submetidas a análises fractográficas das superfícies fraturadas com microscópio eletrônico de varredura FEI®. Foi aplicada a Análise de Variância (ANOVA) dois fatores e o teste de Tukey com significância de 5%. A fixação com duas placas retas de quatro furos apresentou maior resistência à carga (p<0,01) em relação ao grupo de apenas uma placa, independente da marca comercial. A marca Tóride® apresentou média de deslocamento de pico maior que as placas Traumec® quando avaliadas nos grupos com uma placa e extensão de carga no deslocamento de 5mm. As amostras romperam por sobrecarga dúctil, por falha mecânica caracterizada por dano alveolar / Abstract: The purpose of this study was to analyze the mechanical strength of two brands of 1.5 mm system fixation through mechanical linear load test in two fixation methods in aluminum hemimandibles with simulated body fractures and perform fractographic analysis of the samples. Four aluminum structures similar to hemimandibles were fabricated with a linear sectioning simulating a fracture of mandibular body and two hemimandibles were used in each group for posterior fixation with plates and screws with two national brands: Toride® and Traumec®. The group I was fixed with a straight titanium plate with four holes in the compression zone and another one in the tension zone. Group II was fixed with a straight plate with four holes in the neutral zone. For mechanical testing, a universal mechanical testing Instron ® Model 4411 was used and the test was made until final failure of the system (fracture plate). Then, the samples were submitted to fractographic analysis through a scanning electron microscope FEI ®. A analysis of variance (ANOVA) Two-way and Tukey test with 5% significance (?= .05) were applied for statistical analysis. The fixation method with two straight plates showed a higher load resistance (p<0.01) when compared to the group of only one plate, regardless of the brand. The brand Toride® showed an average of peak displacement higher than Traumec® when the groups with only one plate with the extension of 5mm were evaluated. All the samples fractured by ductile overload, characterized by alveolar micromechanisms / Mestrado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Mestre em Clínica Odontológica
27

Comparação entre métodos de fixação interna utilizadas no tratamento de fraturas do ângulo mandibular = estudo mecânico / Comparison of internal fixation methods in the management of mandibular angle fractures : mechanical study

Lyrio, Mariana Camilo Negreiros, 1980- 06 October 2011 (has links)
Orientadores: Valfrido Antonio Pereira Filho, Marcio de Moraes / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-18T20:34:21Z (GMT). No. of bitstreams: 1 Lyrio_MarianaCamiloNegreiros_D.pdf: 27352279 bytes, checksum: c9fcc8fa65410e2e71a94c3f054de2c6 (MD5) Previous issue date: 2011 / Resumo: Apesar dos diversos tipos de fixação interna existentes ainda não há um consenso quanto ao método de imobilização das fraturas do ângulo mandibular. Além disso, são poucos os estudos sobre a utilização de placas grade ultimamente lançadas no mercado. O presente estudo visou avaliar comparativamente a resistência entre três tipos de fixação interna em réplicas de hemimandíbulas de poliuretano seccionadas na região de ângulo mandibular, simulando uma fratura linear. As formas de fixação incluíram a utilização de placas em forma de grade com e sem barra intermediária e o método descrito por Champy (1978). O objetivo foi definir por meio de análise mecânica a técnica que permitiu maior resistência na fixação deste tipo de fratura. Os testes de carregamento linear vertical foram realizados em amostras de cada grupo estudado (n = 10) utilizando uma unidade de testes mecânicos para registro da carga atingida, nos momentos que o deslocamento vertical alcançou 3 mm e 5 mm. Médias e desvio padrão foram avaliados aplicando-se a Análise de Variância e o teste de Duncan em nível de significância de 5%. Concluiu-se que a técnica de fixação interna para as fraturas de ângulo mandibular descrita por Champy (1976) foi a mais resistente e, que a inclusão de barra vertical intermediária nas placas grade não ofereceu aumento da resistência quando comparadas às placas grade sem barra / Abstract: Although there are several methods of stable fixation, there is no consensus about the treatment of mandibular angle fractures, Also, there are few studies about grid plates recently commercially available. This study compares the resistance of three fixation methods in polyurethane hemimandible replicas. Those were osteotomized at the angle region to simulate a linear fracture. Fixation methods were four-hole 2.0mm grid plates with and without a vertical intermediate bar and 2.0mm four-hole straight plate. The objective was to determine, through mechanical analysis, the fixation method that results in greater resistance to displacement. The hemimandibles were submitted to vertical linear loading in a mechanical test unit for registration of load after displacement of 3 and 5mm. Means and standard deviation were determined. Variance analysis and Ducan's test were applied considering a significance level of 5%. Results showed that the 2.0 four-hole plates, positioned according to the Champy technique, provide greater stability than the grid plates. When a vertical intermediate bar was added to the grid plates, resistance of the system was not increased / Doutorado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Doutor em Clínica Odontológica
28

Análise mecânica e fotoelástica de sistemas de fixação interna estável utilizados para o tratamento de fraturas subcondilares da mandíbula / Mechanical and photoelastic analysis of internal fixation systems used for treatment of subcondylar mandibular fractures

Assis, Adriano Freitas de, 1977- 02 March 2012 (has links)
Orientador: Márcio de Moraes / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-19T14:44:31Z (GMT). No. of bitstreams: 1 Assis_AdrianoFreitasde_D.pdf: 2569542 bytes, checksum: c5fe7cff19045423ecf179969933848b (MD5) Previous issue date: 2012 / Resumo: As fraturas do côndilo mandibular apresentam-se como as injúrias mais comuns ao complexo maxilo-mandibular, contudo ainda existe controvérsia quanto ao seu tratamento. O objetivo neste estudo foi avaliar comparativamente, in vitro, por meio de testes mecânicos e fotoelásticos a fixação de fraturas condilares com diferentes sistemas. Para os testes mecânicos foram utilizadas 60 hemimandíbulas de poliuretano, que foram divididas em 12 grupos com 5 hemimandíbulas cada, sendo dois grupos controle com hemimandíbulas íntegras e mais dois grupos de cada tipo de fixação: duas placas retas do sistema 2,0mm, uma placa trapezoidal do sistema 2,0mm, uma placa trapezoidal com extensão do sistema 2,0mm, uma placa trapezoidal do sistema 1,5mm e uma placa trapezoidal com extensão do sistema 1,5mm. Foram realizados testes de carregamento linear no sentido ântero-posterior e médio-lateral. As médias foram comparados pelo teste de Tukey. As diferenças foram consideradas estatisticamente significantes para p ? 0,05. Para os testes fotoelásticos, foi utilizada uma amostra de 10 hemimandíbulas de resina fotoelástica, sendo duas para cada grupo, na mesma distribuição dos testes mecânicos, submetidas ao carregamento linear nos mesmos sentidos para análise do comportamento e distribuição das tensões. Os resultados indicaram que a fixação com duas placas apresenta maior resistência no sentido ântero-posterior e a fixação com uma placa trapezoidal com extensão apresenta maior resistência no sentido médio-lateral. A análise fotoelástica demonstrou que as tensões são melhores distribuídas nas fixações com placas trapezoidais. De acordo com os resultados foi possível concluir que a extensão posterior das placas trapezoidais aumentou a resistência do sistema de fixação e que a utilização de placa trapezoidal com ou sem extensão posterior foi favorável à distribuição de tensão de maneira mais uniforme / Abstract: Fractures of the mandibular condyle are presented as the most common injuries to the maxillo-mandibular complex, however there is still great controversy regarding treatment. The aim of this study was to assess comparatively, in vitro, by mechanical and photoelastic testing, fixation for condylar fractures with different systems. For the mechanical tests 60 polyurethane mandible models were used. They were divided into 12 groups of 5 mandibles, two control groups with intact mandibles and two groups of each type of fixation: two 2.0mm straight plates, a 2.0mm trapezoidal plate, a 2.0mm trapezoidal plate with extension, a 1.5mm trapezoidal plate and a 1.5mm trapezoidal plate with extension. Linear loading tests were carried out in anterior-posterior and medial-lateral directions. Mean and standard deviations were compared by Tukey test. Differences were considered statistically significant at p ? 0.05. For the photoelastic tests, 10 photoelastic mandibles were used, 2 for each group, in the same distribution as the mechanical tests, submitted to linear loading in the same directions to analyze the behavior and distribution of tensile strain lines. The results indicated that the fixation with two plates presented a higher resistance in the anteroposterior direction and fixation with a plate with trapezoidal extension is more resistant towards mediolateral. The photoelastic analysis showed that the strain lines were best distributed when trapezoidal plates were used. According to the results we concluded that the posterior extension of the trapezoidal plates increased the strength of the fixation system, and the use of trapezoidal plate with or without posterior extension was favorable to a more balanced stress distribution / Doutorado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Doutor em Clínica Odontológica
29

Resistência de quatro técnicas de fixação utilizadas no tratamento das fraturas subcondilares = estudo in vitro em mandíbulas de poliuretano / Resistance of four fixation techniques used in the treatment of subcondyles fractures : study in vitro in mandibles of polyurethane

Cavalieri-Pereira, Lucas, 1982- 18 August 2018 (has links)
Orientador: Alexandre Elias Trivellato / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-18T13:54:21Z (GMT). No. of bitstreams: 1 Cavalieri-Pereira_Lucas_M.pdf: 2145596 bytes, checksum: 3e8bd390800cac6c62907f984daa8941 (MD5) Previous issue date: 2011 / Resumo: A fratura do côndilo mandibular usualmente requer tratamento cirúrgico com emprego de fixação interna estável. O objetivo neste estudo foi avaliar comparativamente a resistência de quatro técnicas de fixação utilizadas no tratamento de fraturas subcondilares. Foram empregadas 84 mandíbulas sintéticas, 147 placas retas e 546 parafusos. As mandíbulas foram submetidas a um seccionamento simulando uma fratura subcondilar esquerda e fixadas com quatro técnicas utilizando-se das placas de 2,0 e 1,5 mm, que deram origem a doze grupos experimentais, cada um com 7 mandíbulas. Chamou-se de grupos G1, G5 e G9, aqueles fixados com uma placa reta de 4 furos do sistema 2,0 mm. Os grupos G2, G6 e G10, foram fixados com uma placa de 4 furos dos sistema 2,0 mm e uma placa de 3 furos do sistema 1,5 mm. Grupos G3, G7 e G11, aqueles fixados com duas placas 2,0 mm, sendo a anterior de 3 furos; Grupos G4, G8 e G12, aqueles fixados com duas placas 2,0 mm de 4 furos. Cada sistema foi submetido ao teste de resistência com aplicação de carga no sentido súpero-inferior em máquina de ensaio EMIC, modelo DL2000. Em G1, G2, G3 e G4 a aplicação de carga foi no primeiro molar do lado da fratura simulada (MF). Em G5, G6, G7 e G8, no primeiro molar contralateral à fratura simulada (MC). Em G9, G10, G11 e G12, entre os incisivos centrais (I). Foram mensurados valores de carga para os deslocamentos de 1 mm, 2 mm e 5 mm. Os resultados obtidos no teste de resistência foram comparados utilizando análise de variância (ANOVA), seguido do teste de Tukey com nível de significância de 5%. Verificou-se valores de carga menores no grupo tratado com uma placa de 4 furos do sistema 2,0 mm, nos deslocamentos de 1 e 2 mm, com aplicação de carga em MF. Pode-se concluir que a utilização do sistema de fixação com duas placas proporciona maior resistência / Abstract: Fractures of mandibular condyles usually require surgical treatment with steady employment internal fixation. The aim in this study was to evaluate the resistance of four fixation technique used in the treatment of subcondylar fractures. Were employed 84 synthetic jaws, 147 straight plates and 546 screws. The jaws underwent a sectioning simulating a left subcondylar fracture and fixed with four techniques using 2.0 mm and 1.5 mm plates, which gave rise to twelve experimental groups, each with 7 mandibles. Drew G1, G5 and G9, those set with single straight plate 4-holes. Groups G2, G6 and G10, were fixed with one 2.0 mm system plate 4-holes and one 1.5 mm system plate 3-hole. Groups G3, G7 and G11, were fixed with two plates 2.0 mm, which more anterior had 3-hole. Groups G4, G8 and G12, those fixed with two plates 2.0 mm with 4-hole. Each system was subjected to the test of resistance with load application superior-inferior on testing machine EMIC model DL2000. In G1, G2, G3 and G4 the implementation of load was the first molar side fracture simulated (MF). In G5, G6, G7 and G8 were in the first molar contralateral to the simulated fracture (MC). In G9, G10, G11 and G12 was between the central incisors (I). Load values were measured for displacement from 1 mm, 2 mm and 5 mm. Results obtained in the test of resistance were compared using analysis of variance (ANOVA), followed by Tukey test with a significance level off 5%. There was minor loads value in the group treated with a plate of 4-hole system 2.0 mm, in displacements of 1 and 2 mm, with application in MF. Can conclude that the use of the fixation system with two plates provide greater resistance / Mestrado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Mestre em Clínica Odontológica
30

Atlantoaxial instability : biomechanical evaluation of T-Plate versus transarticular screw fixation

Ciocanel, Despina E. January 2005 (has links)
Thesis (M.S.)--Medical College of Ohio, 2005. / "In partial fulfillment of the requirements for the degree of Master of Science in Biomedical Sciences." Major advisor: Nabil Ebraheim. Includes abstract. Document formatted into pages: iii, 57 p. Title from title page of PDF document. Bibliography: pages 35-42,49-56.