• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 42
  • Tagged with
  • 42
  • 35
  • 28
  • 27
  • 19
  • 17
  • 14
  • 14
  • 13
  • 10
  • 6
  • 6
  • 6
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Avaliação das inclinações dentárias obtidas pela técnica Straight-Wire Prescrição Capelozza Classe II.

Fattori, Liana 08 March 2006 (has links)
Made available in DSpace on 2016-08-03T16:31:12Z (GMT). No. of bitstreams: 1 Liana Fattori.pdf: 2061187 bytes, checksum: 58f918c462dde751cd1b9fb02368aa94 (MD5) Previous issue date: 2006-03-08 / Ao criar a técnica para tratamento ortodôntico denominado Straight-Wire, Andrews introduziu o uso de bráquetes pré-programados, ou bráquetes construídos individualmente para cada dente, com o objetivo de melhor posicioná-los ao final do tratamento. Capelozza Filho sugeriu novas angulações e inclinações para dentes que necessitavam de ajuste ao final do tratamento, criando prescrições para os diferentes padrões faciais. O presente trabalho tem por objetivo avaliar as alterações nas inclinações dentárias causadas pelo tratamento ortodôntico nos dentes anteriores utilizando-se da prescrição Capelozza Classe II. Foram selecionados 17 indivíduos adultos de padrão facial II, portadores de má-oclusão Classe II; para tratamento ortodôntico compensatório, e em três tempos clínicos, relativos a três diferentes fios ortodônticos (.020 ; .019 x .025 , .021 x .025 ), foram realizados exames de tomografia computadorizada volumétrica, para mensuração e posterior avaliação das inclinações dentárias alcançadas em cada um dos tempos, pela ação de cada um dos fios, comparando-se estes valores aos da prescrição utilizada, bem como das diferenças ocorridas entre os tempos. Após a coleta de dados e aplicação dos testes estatísticos, concluiu-se que existe diferença estatística (p<0,05) na maioria dos valores da prescrição e os valores encontrados em cada um dos tempos avaliados; não foram encontradas diferenças estatisticamente significantes quando comparados os tempos estudados. Observou-se também uma tendência dos dentes a expressarem a prescrição apenas em T3.
22

Avaliação da cor de bráquetes estéticos quando submetidos ao desafio corante / Color evaluation of a esthetic brackets when subjected to staining challenge

Flores, Felipe Wehner 20 August 2013 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This study aimed to determine the color stability of aesthetic brackets (plastic and ceramic) when stored in red wine, subjected to daily baths of wine, and immersed in distilled water for different periods. With the aid of a spectrophotometer (SP60 - XRite) and using the CIE L * a * b * system, the initial color parameters and after 15, 30, and 45 days were measured. Brackets of different composition and trademarks were evaluated: Composite (polycarbonate) and Ceramic (polycrystalline ceramic)from Dental Morelli, Maia (polycrystalline ceramic) and Zetta (monocrystalline ceramic)from Eurodonto Orthodontic Products. After the initial color measurements, brackets were divided into 12 groups (n = 10) according to storage media and trademark. The control group remained immersed in distilled water, the wine test group received daily baths of red wine for 15 minutes during the entire period of the study and the immersion test group remained immersed in red wine throughout the study. Repeated readings were performed at 15, 30,and 45 days. Data were submitted to ANOVA and Tukey s test (5%). Color changes were observed in all tested materials, with the greatest change found in group immersioned in red wine, followed by the group subjected to daily baths, and the group stored in distilled water. The polycarbonate showed the greatest color change comparing to ceramics, and the polycrystalline ceramic demonstrated greater color change than monocrystalline ceramic. For all tested groups, the longer the period the greater the changes in color. The type of material and the time in contact with the staining agente had a directly influence in the color stability of brackets. / O presente trabalho teve como objetivo verificar a estabilidade de cor de bráquetes estéticos (plásticos e cerâmicos) quando armazenados em vinho tinto, submetidos a banhos diários de vinho tinto e imerso em água destilada, durante períodos de tempo distintos. Com o uso de um espectrofotômetro (SP60 - X-Rite), empregando o sistema CIE L* a* b*, os parâmetros de cor inicial e após 15, 30e 45 dias foram aferidos. Bráquetes de diferentes composições e marcas comerciais foram avaliados: Composite (policarbonato) e Ceramic (cerâmica policristalina) da Dental Morelli, Maia (cerâmica policristalina) e Zetta (cerâmica monocristalina),da Eurodonto Produtos Ortodônticos. Após a mensuração da cor inicial, os bráquetes foram divididos em 12 grupos (n=10) de acordo com os meios de armazenamento e marca comercial. O grupo controle permaneceu imerso em água destilada, o grupo teste de banho em vinho foi colocado em vinho tinto por 15 minutos diários durante o período do estudo e o grupo teste de imersão permaneceu imerso em vinho tinto durante todo o período dos testes. Sucessivas leituras foram realizadas nos períodos de 15, 30 e 45 dias. Os dados foram submetidos à Análise de Variância e teste de Tukey (5%).Encontrou-se alteração de cor em todos os materiais testados, sendo a maior encontrada na imersão contínua em vinho tinto, seguida do grupo submetido a banhos diários e do grupo em água destilada. O policarbonato sofreu a maior alteração de cor em relação às cerâmicas e a cerâmica policristalina sofreu maior alteração de cor em relação à cerâmica monocristalina. Em tempos mais longos houve maior alteração em todos os grupos. O tipo de material e o tempo de contato com a substância corante influenciaram diretamente na estabilidade da cor dos bráquetes.
23

Avaliação espectrofotométrica das alterações cromáticas de bráquetes estéticos armazenados em soluções potencialmente corantes

Fabre, Aubrey Fernando [UNESP] 17 December 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-12-17Bitstream added on 2014-06-13T20:57:10Z : No. of bitstreams: 1 fabre_af_me_araca.pdf: 1176776 bytes, checksum: 82e65eb62f8fff32b44bf512beef8e61 (MD5) / Objetivos. O presente estudo avaliou o comportamento cromático de bráquetes estéticos de diferentes materiais armazenados em soluções potencialmente corantes (água destilada, refrigerante, café e enxaguatório contendo álcool). Métodos. As amostras foram divididas em quatro grupos de acordo com a marca comercial e armazenadas em quatro tipos de soluções (água destilada, refrigerante, café e enxaguatório contendo álcool) a 37°C durante 14 dias. As possíveis alterações de cor foram mensuradas por meio de um espectrofotômetro de reflectância em cinco intervalos de tempo após o armazenamento. As alterações de cor foram registradas de acordo com o sistema CIE L*a*b* e a análise estatística foi conduzida empregando-se ANOVA a 1%, aplicação dos testes de Tukey e decomposição das interações com nível de significância a 5%. Resultados. As alterações de cor foram dependentes da solução, tempo de armazenamento e marca dos bráquetes. As maiores alterações de cor foram observadas nos bráquetes Invu™, seguido pelo Silkon Plus™, Composite® e Transcend™, com diferenças estatisticamente significantes. Significância. As soluções potencialmente corantes podem interferir na aparência dos bráquetes estéticos. Portanto, quando estes acessórios são utilizados, os pacientes devem ser informados sobre a possibilidade das alterações de cor ao longo do tempo e da necessidade de redução do consumo de produtos com potencial corante. / Objectives. The aim of this study was evaluated the chromatic behavior of the esthetic brackets of different materials exposure at the immersion in potentially staining solutions (distilled water, soda, coffe and mouthrinse with alcohol). Methods. The sample were divided in four groups of agreement with the commercial brand and stored in four types of the solutions (distilled water, soda to the base of cola, cofee and mouthrinse containing alcohol) at 37°C for 14 days. Color changes were measured by a reflection spectrophotometer in five time intervals after storage. The color changes were recorded according to the CIE L*a*b* system and the statistical analysis were carried out using ANOVA to 1%, application of the tests of Tukey and the decomposition of interactions with a significance level of 5%. Results.The color changes were dependent on the solution, storage time and the brand of brackets. The largest color changes were observed in the Invu™, followed by Silkon Plus™, Composite® and Transcend™ brackets, with statistic significance. Significance. The potentially staining solutions can interfere in the desirable appearance of esthetic brackets. Thus, when these attachments are used, the patient should be informed about possible color changes in the long-therm, and should reduce the consumption of potentially staining produtos.
24

Braquete ortodôntico com gancho alongado verticalmente e semi-flexível

Duque, Paulo Henrique da Rocha 08 August 2017 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-11-06T13:37:53Z No. of bitstreams: 1 paulohenriquedarochaduque.pdf: 1698700 bytes, checksum: 10981084ef7d6b6c2e58c081df3f2f4f (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-11-09T14:24:07Z (GMT) No. of bitstreams: 1 paulohenriquedarochaduque.pdf: 1698700 bytes, checksum: 10981084ef7d6b6c2e58c081df3f2f4f (MD5) / Made available in DSpace on 2017-11-09T14:24:08Z (GMT). No. of bitstreams: 1 paulohenriquedarochaduque.pdf: 1698700 bytes, checksum: 10981084ef7d6b6c2e58c081df3f2f4f (MD5) Previous issue date: 2017-08-08 / Durante o tratamento ortodôntico é frequente que o profissional realize movimentos distais dos dentes. Uma forma eficiente para movimentar um dente sem que inclinações indesejadas aconteçam é aproximar as forças do centro de resistência dentário (CR). Não foi encontrado na literatura citações de bráquetes préfabricados com ganchos de altura que permitam que a força aplicada a eles passe pelo CR. Desenvolver um protótipo virtual de um acessório ortodôntico com o gancho alongado verticalmente e realizar testes através do Método de Elementos Finitos (MEF) para avaliar o comportamento biomecânico do dente, simulando três situações de exposição de forças: passando pelo CR, acima do CR e abaixo do CR. Foi desenvolvido um bráquete ortodôntico com uma extensão vertical de 15 mm de altura e 1 mm de diâmetro em sua aleta distal. Através do MEF foi realizada a simulação da aplicação de forças no sentido distal do canino utilizando o bráquete com o dispositivo criado. A criação do protótipo virtual para realização dos testes em MEF foi realizada com êxito. Observou-se que a tendência de deslocamento do canino obteve um maior movimento de corpo quando a força estava passando próximo ao CR. / During orthodontic treatment, the professional often performs distal movements of the teeth. An efficient way to move a tooth without undesired inclinations is to approach the forces of the center of tooth resistance (RC). We have not found in the literature quotes of prefabricated brackets with height hooks that allow the force applied to them to pass through the RC. The objective of the present study was to develop a virtual prototype of an orthodontic attachment with the hook vertically elongated and perform tests using the Finite Element Method (FEM) to evaluate the biomechanical behavior of the tooth, simulating three situations of force exposure: passing through the RC, above the RC and below the RC. An orthodontic bracket with a vertical extension of 15 mm in height and 1 mm in diameter was developed in its wings. Through the FEM, the simulation of the application of forces in the distal direction of the canine was performed using the bracket with the created device. The creation of the virtual prototype to perform the MEF tests was carried out successfully. It was observed that the movement tendency of the canine obtained a greater body movement when the force was passing near the RC.
25

Avaliação da profundidade da canaleta dos bráquetes autoligados passivos associados à expressão do torque / Evaluation of the slot depth of passive self-ligating brackets associated with torque expression

Patrick Cavallini Saraiva 24 March 2017 (has links)
Um dos fatores responsáveis para o sucesso do tratamento ortodôntico é o controle do movimento dentário nos três planos do espaço. Nos bráquetes autoligados e pré-ajustados, a inclinação dos dentes no sentido vestíbulo-lingual depende diretamente da interação bráquete/ fio. Sabendo-se da importância do controle do torque, o propósito deste estudo foi definir a folga entre bráquetes/ fio, avaliar o momento de torque, e correlacionar estes valores nos bráquetes autoligados passivos com profundidades de canaletas diferentes (Damon Q e H4). Para esta pesquisa foi confeccionado um dispositivo experimental em conjunto com uma máquina de testes universal (Model 5565, Instron, Canton, Mass) para medir a expressão do torque nos bráquetes ortodônticos. Para verificar se a difereça na profundidade das canaletas dos bráquetes interferiram na expressão do torque, foram realizadas análises de variância (ANOVA), e teste de Tukey (p<0,05) para identificar as diferenças entre os grupos. Os bráquetes H4 apresentaram maior folga entre bráquete/ fio, quando comparados aos bráquetes Damon Q. Ao avaliarmos o momento de força da expressão do torque, os bráquetes H4 e Damon Q apresentaram diferenças estatisticamente significantes apenas com 24º e 36º de torção. Após a análise dos resultados, ao comparar os valores da expressão de torque com 12º, 24º e 36º, observamos maior expressão de torque no bráquete Damon Q quando comparado ao bráquete H4; Observamos também que o Damon Q expressa melhor o torque quando comparado com o H4, com momentos de força de 5 Nmm, 10 Nmm, 15 Nmm e 20 Nmm. / One of the factors responsible for the success of orthodontic treatment is the control of tooth movement in the three planes of space. In self-ligating and pré-adjusted brackets, the labio-lingual inclination of the teeth depends directly the bracket / wire interaction. Knowing the importance of torque control, the purpose of this study was to define the play between the brackets and wires, to evaluate the moment of torque, and to compare these values in passive self-ligating brackets with different slot depths (Damon Q and H4). For this research, an experimental device was designed in conjunction with a universal test machine (Model 5565, Instron, Canton, Mass) to measure the torque expression in orthodontic brackets. To verify if the differences in the depth of the bracket slots interfered in the torque expression, analyzes of variance (ANOVA) and Tukey test (p <0.05) were performed to identify the differences between the groups. The H4 bracket had the highest play when compared to the Damon Q bracket. When evaluating the moment of torque expression, bracket H4 and Damon Q presented statistically significant differences only with 24º and 36º of torsion. After the analysis of the results, when comparing the values of the torque expression with 12º, 24º, and 36º, we observed greater torque expression in the Damon Q bracket when compared to the bracket H4; we also observed that the Damon Q expressed better the torque when compared with H4, with moments of force of 5 Nmm, 10 Nmm, 15 Nmm, and 20Nmm.
26

Análise fotoelástica das tensões produzidas por arcos ortodônticos expandidos associados aos bráquetes autoligáveis e convencionais / Photoelastic analysis of tensions produced by expanded orthodontic arches associated with self-ligating and conventional brackets

Helena Cristina Francisco Pereira da Silva 02 May 2018 (has links)
O objetivo desta pesquisa foi avaliar as áreas de tensões produzidas por arcos ortodônticos expandidos associados a diferentes tipos de bráquetes durante a fase de alinhamento e nivelamento ortodôntico. A partir de modelos de gesso adquiridos durante a fase de nivelamento ortodôntico do arco dentário inferior de um mesmo paciente, obteve-se 3 modelos fotoelásticos que receberam 3 diferentes tipos de bráquetes: convencional (Ovation®, GAC International, New York, EUA), autoligável ativo (In-Ovation®, GAC International, New York, EUA) e autoligável passivo (Damom 3MX®, Ormco, Califórnia, EUA), associados a arcos de liga de níquel-titânio 0.014\" e 0.014\" x 0.025\" e de liga de aço 0.019\" x 0.025\". Os modelos fotoelásticos com os respectivos arcos e bráquetes ortodônticos foram observados em polariscópio circular, e as imagens fotográficas das regiões dos incisivos, pré-molares e molares foram analisadas qualitativa e quantitativamente. A análise qualitativa foi realizada pela identificação da ordem e coloração das franjas nos locais onde ocorreram, e a quantitativa foi realizada utilizando o software Matlab® para a identificação dos padrões de cores RGB nas áreas dos terços médio-apicais dos dentes de cada região. Os dados obtidos das diferentes associações arcos/bráquetes ortodônticos foram comparados estatisticamente pelo teste de Wilcoxon. Pode-se concluir que, na região dos incisivos, as maiores tensões ocorreram quando os arcos ortodônticos foram associados aos bráquetes autoligados passivos. Na região dos pré-molares, as maiores tensões ocorreram quando o arco 0.014\" foi associado ao bráquete convencional, em movimentos de segunda ordem (extrusão) e de angulação, e quando os arcos retangulares foram associados aos bráquetes autoligados passivos. Na região dos molares, as maiores tensões ocorreram quando os arcos retangulares foram associados aos tubos ortodônticos com maior prescrição de inclinação (Ovation® e In-Ovation®). / The aim of this research was to evaluate the areas of tension produced by expanded orthodontic arches associated with different types of brackets during the orthodontic leveling phase. From plaster models of a single patient lower dental arch obtained during the orthodontic alignment and leveling phase, three photoelastic models were developed that received three different types of brackets: convencional (Ovation®, GAC International, New York, EUA); active self ligation bracktes (In-Ovation®, GAC International, New York, EUA) e passive self ligation bracktes (Damom 3MX®, Ormco, Califórnia, EUA), associated with 0.014\" and 0.014\" ? 0.025\" titanium-nickel alloy arches and 0.019\" ? 0.025\" alloy steel arches. These models were analyzed in a circular polariscope; photographic images of the incisor, premolar, and molar regions were qualitatively and quantitatively analyzed. The first analysis was obtained by identifying the photoelastic fringe order at sites where they occurred, and the second one was obtained using Matlab® software to identify RGB color patterns in middle apical tooth areas of each region. Data from the different orthodontic arches and brackets were compared using the Wilcoxon test. Our results showed that in the incisors region the greatest tensions occurred when the orthodontic arches were associated to the self-ligating passive brackets; in the premolars region, by the association of the 0.014\" arch and conventional bracket in second order (extrusion) and angulation movements and when the rectangular arches were associated with the passive self-ligating brackets. The greatest tensions in the molar regions occurred by association of rectangular arches and inclination high prescriptions orthodontics tubes (Ovation® and In-Ovation®).
27

Comparação das taxas de liberação in vitro de níquel e cromo por bráquetes ortodônticos de diferentes marcas comerciais. / Comparison of rates of in vitro release of nickel and chrome for orthodontic brackets of different trademarks

Ana Cristina Soares Santos Haddad 09 March 2007 (has links)
Com o propósito de auxiliar o ortodontista na escolha de braquetes ortodônticos com menor potencial tóxico, seja local ou sistêmico, para seus pacientes, o objetivo deste estudo foi comparar diferentes marcas comerciais de braquetes ortodônticos, a fim de identificar, em ambientes orais simulados durante 28 dias, aquelas marcas que liberam as menores taxas de Ni e Cr. Para tal, foram empregados 280 braquetes divididos igualmente de acordo com o modelo e a marca comercial: (1) Kirium Line® Abzil®, (2) Mini Master Series® American Orthodontics®, (3) Discovery® Dentaurum®, (4) Full Size® Unitek®, (5) Morelli M.B.T.® Morelli®, (6) NuEdge® TP Orthodontics® e (7) Victory® Unitek®. A norma ISO 10271/2001 foi utilizada para padronização do método. Cada braquete foi imerso em 0,5 mL de saliva sintética ou de fluido de placa artificial durante 28 dias a 37°C. A cada 7 dias, a solução foi substituída e analisada por um espectrômetro de absorção atômica e atomização eletrotérmica (ETAAS) ou por espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES) para quantificação do conteúdo (?g L-1) de Ni e Cr nas soluções. O teste Kruskall-Wallis foi empregado para determinação das diferenças estatísticas entre as taxas de liberação de Ni e Cr pelos braquetes das marcas comerciais estudadas nas duas soluções de imersão. Os resultados indicaram que as diferentes marcas comerciais de braquetes apresentaram diferentes comportamentos corrosivos. Além disso, a solução de fluido de placa provocou a liberação de quantidades significativamente maiores de Ni e Cr, em comparação com a solução de saliva sintética. Portanto, pôde-se concluir que a marca comercial, cujos braquetes apresentaram as menores taxas de liberação de Ni e Cr, foi a Dentaurum®, seguida, em ordem crescente, pelas marcas Victory® Unitek®, American®, TP®, Full Size® Unitek®, Morelli® e Abzil®. / In order to assist orthodontists on choosing brackets with less potential to induce local or systemic toxicity to their patients, this study aimed at comparing different manufacturers of orthodontic brackets and at identifying the ones that released less amounts of nickel (Ni) and chromium (Cr) in simulated oral environments. 280 brackets were equally divided according to the following models and manufacturers: (1) Kirium Line® Abzil®, (2) Mini Master Series® American Orthodontics®, (3) Discovery® Dentaurum®, (4) Full Size® Unitek®, (5) Morelli M.B.T. ® Morelli®, (6) NuEdge® TP Orthodontics®, and (7) Victory® Unitek®. International standard ISO 10271/2001 was applied to provide test methods. Each bracket was immersed in 0.5 mL of synthetic saliva or artificial plaque fluid during 28 days at 37°C. Solutions were replaced every 7 days, and were analyzed by means of an electrothermal atomic absorption spectrometer (ETAAS) or by an inductively coupled plasma optical emission spectrometer (ICP OES) to quantify (g L-1) the amount of Ni and Cr released. Kruskall-Wallis test was applied to determine if differences existed between Ni and Cr release according to bracket manufacturers and to solutions. Results indicated that brackets from different manufacturers presented different corrosion behavior. In addition, artificial plaque fluid induced more Ni and Cr release then artificial saliva. It was therefore concluded that brackets from Dentaurum® presented the less quantities of Ni and Cr released in both studied solutions. Increasing rates of Ni and Cr were detected to the following manufacturers: Victory® Unitek®, American®, TP®, Full Size® Unitek®, Morelli® e Abzil®.
28

Propriedades físico-químicas de bráquetes e fios ortodônticos utilizados em diferentes tempos de tratamento

Ramos, Aretha Aliny dos Santos 18 February 2014 (has links)
Submitted by Maike Costa (maiksebas@gmail.com) on 2017-03-16T12:14:26Z No. of bitstreams: 1 arquivototal.pdf: 1679756 bytes, checksum: 5065ecafba4b6ac4c0113ddd5cc81002 (MD5) / Made available in DSpace on 2017-03-16T12:14:26Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 1679756 bytes, checksum: 5065ecafba4b6ac4c0113ddd5cc81002 (MD5) Previous issue date: 2014-02-18 / OBJECTIVE: The focus of this study was to test the hypothesis that treatment time and oral pH had an influence on the physical chemical properties of orthodontic brackets and arch wires. METHODS: 120 metal brackets were evaluated. They were divided into 4 groups (n=30): Group C (Control) and Groups T12, T24 and T36 (brackets recovered after 12, 24, and 36 months of treatment, respectively), rectangular stainless steel arch wires that remained in the oral cavity for 12 to 24 months were also analyzed. Dimensional stability, surface morphology and composition of brackets, resistance to sliding of the bracket/wire set and surface roughness of wires were analyzed by optical microscopy by measurement, scanning electron microscopy and energy dispersive x-ray, universal test machine and atomic force microscopy assays, respectively. Oral pH was evaluated by means of pH indicator strips by the colorimetric method. One-way analysis of variance ANOVA, followed by Tukey multiple comparisons test were used for statistical analysis (p<0.05). RESULTS: There was gradual influence of time from the 12th to 36th month for biofilm and food debris accumulation on bracket surfaces, presence of deformations on winglets and points of corrosion. Occlusal and cervical heights of brackets increased significantly after clinical use for 36 months, compared with new bracket heights (p<0.05). Carbon and Oxygen were shown to be elements that increased expressively and in direct proportion to time, and there was a progressive increase in the coefficient of friction and roughness of wires as a function of time of clinical use after 36 months. Oral pH showed significant difference only between group T36 and its control (p<0.05). CONCLUSIONS: The hypothesis was partially accepted, brackets and orthodontic wires suffered significant physical-chemical changes due to clinical use. However, the treatment time and biofilm and debris accumulation in bracket slots were shown to have more influence on the degradation process and frictional force of these devices than oral pH. / OBJETIVO: Este estudo teve como foco atestar a hipótese de que o tempo de tratamento e o pH bucal possuem influência sobre as propriedades físico-químicas de fios e bráquetes ortodônticos. MÉTODOS: Cento e vinte bráquetes metálicos foram avaliados, divididos em 4 grupos (n=30 por grupo): grupo C (Controle, como recebido do fabricante) e os grupos T12, T24 e T36 (bráquetes recuperados após 12, 24, e 36 meses de tratamento, respectivamente), fios de aço inoxidável retangulares que permaneceram na cavidade oral por 12 a 24 meses também foram analisados. Estabilidade dimensional, morfologia da superfície e composição dos bráquetes, resistência ao deslizamento do conjunto bráquete/fio e rugosidade superficial dos fios foram analisados por microscopia óptica de medição, microscopia eletrônica de varredura e por energia dispersiva de Raios X, máquina universal de ensaios e microscopia de força atômica, respectivamente. O pH bucal foi avaliado nos diferentes tempos de tratamento a partir de tiras indicadoras de pH pelo método colorimétrico. RESULTADOS: O tempo influenciou gradativamente do 12° ao 36° mês para o acúmulo de biofilme e detritos alimentares sobre a superfície dos bráquetes, presença de deformações nas aletas, além do aparecimento de pontos de corrosão. Alturas oclusal e cervical dos bráquetes aumentaram significativamente após o uso clínico de 36 meses comparado as alturas dos bráquetes novos (p<0.05). Carbono e Oxigênio demonstraram ser elementos com aumentos expressivos e diretamente proporcional ao tempo, assim como, houve um aumento progressivo do coeficiente de atrito e rugosidade dos fios em função do tempo de uso clínico com maior aumento após 36 meses. O pH bucal demonstrou diferença significativa apenas entre o grupo T36 com seu controle (p<0.05). CONCLUSÕES: A hipótese foi parcialmente aceita, bráquetes e fios ortodônticos apresentaram alterações físico-químicas significativas devido ao uso clínico. No entanto, o tempo de tratamento e o acúmulo de biofilme/detritos nos slots dos bráquetes demonstraram ser mais influentes sobre o processo de degradação e força de atrito destes dispositivos do que o pH bucal.
29

Análise in vitro do esmalte dentário, após diferentes métodos de remoção de resina composta residual utilizada para a colagem de bráquetes ortodônticos, em microscopia eletrônica de varredura / Analysis of dental enamel in vitro after different methods of residual resin removal using for bonding orthodontic brackets in scanning electron microscopy

Oliveira, Mileide de 23 August 2011 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-05-04T15:39:10Z No. of bitstreams: 1 mileidedeoliveira.pdf: 2044599 bytes, checksum: cf2ec66abb87f42a989dc30fefcd5872 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-06-07T15:34:33Z (GMT) No. of bitstreams: 1 mileidedeoliveira.pdf: 2044599 bytes, checksum: cf2ec66abb87f42a989dc30fefcd5872 (MD5) / Made available in DSpace on 2016-06-07T15:34:33Z (GMT). No. of bitstreams: 1 mileidedeoliveira.pdf: 2044599 bytes, checksum: cf2ec66abb87f42a989dc30fefcd5872 (MD5) Previous issue date: 2011-08-23 / O presente estudo teve como objetivo analisar, in vitro, a superfície do esmalte dentário após diferentes métodos de remoção de resina residual após a descolagem de bráquetes ortodônticos metálicos. Foram utilizados 25 pré-molares humanos, hígidos, extraídos por indicação ortodôntica, os quais tiveram suas porções radiculares incluídas em resina acrílica, em matriz rígida de PVC. Em todos os espécimes foram colados bráquetes ortodônticos metálicos (Edgewise – Morelli) com a resina ortodôntica quimicamente ativada Super Bond (Ortho Source), de acordo com as orientações do fabricante. Os espécimes ficaram imersos em saliva artificial por 24 horas e em seguida foram removidos os bráquetes. Os espécimes foram divididos aleatoriamente em cinco grupos, de acordo com o método de remoção da resina remanescente. No grupo 1 a resina foi removida com aparelho de ultrasson (Altsonic), no grupo 2 com broca multilaminada 30 lâminas (JET) , no grupo 3 com ponta de óxido de alumínio (pedra Arkansas branca tipo pêra), no grupo 4 com alicate removedor de resina e no grupo 5 com discos de lixa (TDV) em ordem decrescente de granulação. Após a remoção da resina residual os espécimes tiveram suas coroas seccionadas com disco de carborundum no sentido transversal e longitudinal, deixando apenas a superfície vestibular da coroa para ser analisada em microscopia eletrônica de varredura. Os resultados foram submetidos à análise estatística, pelos testes de Anova e Tukey, com índice de significância de 5%. A broca multilaminada 30 lâminas e a ponta de óxido de alumínio foram os métodos que menos danificaram a superfície do esmalte, apresentando resultados estatisticamente significantes em relação aos outros métodos e deixando a superfície do esmalte satisfatória após a remoção da resina residual. / This study aimed to evaluate, in vitro, the enamel surface after different methods of removing residual resin after debonding of orthodontic brackets of metal. We used 25 human premolar, extracted for orthodontic indication, which had their root portions embedded in acrylic resin in rigid PVC matrix. In all specimens were bonded metallic orthodontic brackets (Edgewise - Morelli) with chemically cured orthodontic resin Super Bond (Ortho Source), according to the manufacturer's guidelines. The specimens were immersed in artificial saliva for 24 hours and then the brackets were removed. The specimens were randomly divided into five groups according to the method of removing residual resin. In group 1 the resin was removed with ultrasoun equipment (Altsonic) in group 2 with tungsten carbide bur (JET) in group 3 with aluminum oxide blaster (white Arkansas stone pear type) in group 4 with plier remover resin and in group 5 with sanding discs (TDV) in descending order of grain. After removing the residual resin specimens had their crowns sectioned with a carborundum disk in transverse and longitudinal, leaving only the buccal surface of the crown to be analyzed in scanning electron microscopy. The results were statistically analyzed by ANOVA and Tukey tests with significance level of 5%. The tungsten carbide bur and aluminum oxide blaster methods were less damaged enamel surfaces, with statistically significant results compared to other methods, leaving the enamel surface satisfactory after residual resin removal.
30

Tratamento térmico em bases de bráquetes monocristalinos silicatizados e silanizados: efeito na adesão ao esmalte

Silva, Emília Adriane 15 September 2011 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-07-13T13:59:40Z No. of bitstreams: 1 emiliaadrianesilva.pdf: 2213397 bytes, checksum: 9d1b10517697f8e5f79ea9e57c98368a (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-07-13T16:55:53Z (GMT) No. of bitstreams: 1 emiliaadrianesilva.pdf: 2213397 bytes, checksum: 9d1b10517697f8e5f79ea9e57c98368a (MD5) / Made available in DSpace on 2016-07-13T16:55:53Z (GMT). No. of bitstreams: 1 emiliaadrianesilva.pdf: 2213397 bytes, checksum: 9d1b10517697f8e5f79ea9e57c98368a (MD5) Previous issue date: 2011-09-15 / O objetivo deste trabalho foi avaliar o efeito do tratamento térmico na adesão de bráquetes monocristalinos silanizados após processo de silicatização. O estudo foi autorizado pelo comitê de ética da Universidade Federal de Juiz de Fora, parecer número 161/2010. Sessenta bráquetes de alumina monocristalina (Pure®, Orthotechnology, Tampa, FL, EUA) e sessenta dentes pré-molares superiores recém extraídos com finalidade ortodôntica foram randomicamente divididos em três grupos (n=20) de acordo com a estratégia de tratamento das superfícies adesivas: G1- sem tratamento (grupo controle); G2- jateamento com partículas de alumina revestidas por sílica-30 µm Cojet (3M ESPE, Irvine, CA, EUA) + aplicação do silano Monobond S (Ivoclar Vivadent, Shaan, Liechtenstein); e G3- jateamento com Cojet seguido de silanização e tratamento térmico da superfície com jato de ar (Secador Taiff Compacto Turbo, 6000W, São Paulo, SP) à 100ºC±1, a 1 cm por 60 s. Após os tratamentos de superfície, os bráquetes foram colados aos dentes com o adesivo ortodôntico Transbond XT Light Cure Adhesive (3M ESPE, Irvine, CA, EUA). Os espécimes foram armazenados em estufa com água destilada a 37ºC por 100 dias. Durante este período, metade dos espécimes de cada grupo foi submetida à termociclagem (-T) (6000 ciclos, 5ºC±1 e 55ºC±1) com banhos alternados de 30 s. Com o auxílio de uma máquina universal para ensaios mecânicos (EMIC - DL 1000, São José dos Pinhais, Paraná, Brasil – F.O. Unesp, São José dos Campos, SP) e um dispositivo tipo faca, os grupos foram submetidos ao ensaio de resistência adesiva ao cisalhamento (1mm/min) até que ocorresse o descolamento dos bráquetes. As superfícies fraturadas foram observadas sob microscopia óptica (30×) para categorização dos tipos de falha e determinação do índice de remanescente adesivo (IRA). Doze amostras representativas (n=2) foram também observadas em microscopia eletrônica de varredura. Os resultados foram submetidos à análise estatística ANOVA (2-fatores) e as médias foram comparadas pelo teste de Tukey com nível de significância em 5% para ambos os testes. Para os resultados de resistência adesiva, o teste ANOVA revelou significância estatística para a interação dos fatores tratamento de superfície e termociclagem (p= 0,013) e para o tratamento de superfície (p= 0,0). O fator termociclagem não influenciou estatisticamente os resultados (p = 0,6974). As maiores e menores médias de resistência adesiva com o desvio padrão foram encontradas respectivamente em G3-T (27,59 ± 6,4 MPa) e G2-T (8,45 ± 6,7 MPa). Na análise da superfície após o ensaio, foi constatada a fratura de esmalte e/ou dentina em dezesseis espécimes. Com exceção do grupo G2, todos os outros apresentaram fratura de estrutura dentária. O modo de falha tipo misto e IRA = 1 (49,12%) foram os mais frequentes. Conclui-se que o tratamento térmico das superfícies silanizadas após o jateamento com partículas de alumina revestidas por sílica produziu valores de resistência adesiva similares aos valores encontrados no grupo controle. / The objective of this study was to evaluate the effect of heat treatment on bond strength of monocrystalline brackets silica coating and silanization process. The study was approved by the ethics committee of the Federal University of Juiz de Fora, autorization number 161/2010. Sixty brackets monocrystalline alumina (Pure®, OrthoTechnology, Tampa, FL, EUA) and sixty premolars recently extracted for orthodontic were randomly, divided in three groups (n=20) according to the strategy of treating surfaces adhesive: G1 – no treatment (control group), G2 – blasting with alumina particles coated with silica 30 µm Cojet (3M ESPE/ Irvine, CA, EUA) + application of silane Monobond S (Ivoclar Vivadent, Shaan, Liechtenstein), and G3 – blasting (Cojet) + silanization + heat treatment with a hairdryer (Taiff Compact Turbo Dryer, 6000W, São Paulo, SP) to 100ºC ± 1, to 1 cm, for 60 s. After surface treatments, the brackets were bonded to teeth with orthodontic adhesive Transbond XT Light Cure Adhesive (3M ESPE, Irvine, CA, EUA). The specimens were stored in distilled water for 100 days. During this period, half of the specimens of each group was subjected to thermocycling (-T) (6000 cycles, 5ºC ± 1ºC and 55ºC ± 1) with baths of 30 seconds. With the support of a universal mechanical testing machine (EMIC – DL 1000, Pinhais, Paraná, Brazil – FO/UNESP, São José dos Campos, SP) an device like a knife, the groups were submitted a shear bond strength test (1mm/min) until failure. The fractured surfaces were observed under debonded specimen surfaces were examined with a stereomicroscope (30×) to classify the types of failure and determine the adhesive remnant index (ARI). Twelve representative samples (n=2) were also observed in scanning electron microscopy. The results were statically analyzed using ANOVA (two-way) and means were compared by Tukey test with significance level of 5% for both tests. For the results of bond strength, the ANOVA revealed statistical significance for the interaction of surface treatment and thermocycling (p= 0,013) and the surface treatment (p= 0,0). The factor thermocycling did not influence the results statistically (p= 0,6974). The highest and lowest mean bond strength including the standard deviation were found in G3T (27,59 ± 6,4 MPa) and G2T (8,45 ± 6,7MPa). In the analysis of the surface after test was found sixteen specimens with enamel/dentin fracture. Except for G2, all others groups had fractured tooth structure. The failure mode mixed and IRA=1 (49,12%) were the most frequent. The heat treatment of the silanized surfaces after blasting with alumina particles coated with silica produced bond strength values similar to those found in the control group.

Page generated in 0.0839 seconds