• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 55
  • 8
  • 8
  • 8
  • 8
  • 7
  • 7
  • 6
  • 4
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 57
  • 57
  • 28
  • 27
  • 23
  • 22
  • 15
  • 13
  • 12
  • 12
  • 11
  • 11
  • 11
  • 10
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Análise comparativa da falha adesiva de resinas ortodônticas em ensaio mecânico in vitro e pelo método de elementos finitos / Ana Letícia Rocha Avila ; orientador, Orlando Tanaka ; co-orientadora Mildred Ballin Hecke

Ávila, Ana Letícia Rocha January 2010 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2010 / Inclui bibliografias / Tratamento ortodôntico com aparelho fixo requer a colagem de brackets na superfície do esmalte dentário sem falhas de adesão durante e período de tratamento, porém possibilitando descolagem segura e sem causar danos na superfície do esmalte. O objetivo de / Orthodontic treatment requires fixed appliances that do not fail during the treatment period and that can be safely de-bonded thereafter. The purpose of this study was to investigate and compare the adhesive failure patterns obtained from in vitro mechani
12

Degradação de brackets ortodônticos no meio bucal e sua relação com a fricção = Biodegradation of orthodontic metallic brackets and associated implications for friction / Saulo Regis de Oliveira Junior ; orientador, Hiroshi Maruo ; Paulo Soares / Biodegradation of orthodontic metallic brackets and associated implications for friction

Oliveira Junior, Saulo Regis de January 2008 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2008 / Inclui bibliografias / A exposição in vivo pode promover alterações significativas nos biomateriais metálicos, e consequente prejuízo do seu desempenho funcional. objetivou-se avaliar e comparar a morfologia, dimensões e resistência friccional de brackets ortodônticos metálico / In vivo exposure may promote significant alterations in metallic biomaterials, with consequent impairment of their clinical performance. This study aimed to assess and compare the surface morphology, dimensions and frictional behavior of as-received and r
13

Análise citológica da mucosa bucal, adjacente a brackets e ligaduras metálicas ou elásticas, = Cytologic analysis of the oral mucosa adjacent to brackets and metal or elastic ligatures / Raul Magnoler Sampaio Mei ; orientadora, Elisa Souza Camargo ; co-orientador, Antônio Adilson Soares de Lima / Cytologic analysis of the oral mucosa adjacent to brackets and metal or elastic ligatures

Mei, Raul Magnoler Sampaio January 2008 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2008 / Inclui bibliografias / Objetivos: Avaliar pela citologia esfoliativa em base líquida possíveis alterações citológicas das células epiteliais adjacentes a acessórios ortodônticos. Design do Estudo: Em 20 indivíduos foram colados brackets nos pré-molares superiores e amarrados fi / Objectives: Evaluate the possible cytological alterations of epithelial cells adjacent to orthodontic accessories by liquid-based exfoliative cytology. Study Design: In 20 individuals, brackets were bonded to the maxillary premolars, and wires were tied w
14

AVALIAÇÃO DAS ALTERAÇÕES DENTÁRIAS E DO PERFIL FACIAL OBTIDAS NO TRATAMENTO ORTODÔNTICO COM BRAQUETES AUTOLIGADOS / Assessment of dental alterations and facial profile obtained in orthodontic treatment with self-ligating brackets

Kochenborger, Ricardo 25 March 2009 (has links)
Made available in DSpace on 2016-08-03T16:31:13Z (GMT). No. of bitstreams: 1 Ricardo Kochenborger.pdf: 1120421 bytes, checksum: 6754691064f7c009ddbd2460256d1396 (MD5) Previous issue date: 2009-03-25 / This study aimed to evaluate the dental inclinations and facial profile of patients treated with orthodontic self-ligating brackets Damon 2, standard prescription. For this study, we selected a sample of 18 subjects, 12 males and 6 females, with ages ranging from 12 to 20 years (mean age 15 years) and who had negative discrepancy model (from 4 mm to 15 mm). As a criterion for inclusion, the patients should have permanent complete dentition until the second molars, Class I Angle malocclusion, cephalometric lateral radiographs before and after orthodontic treatment and dental casts of the upper and lower dental arches before and after orthodontic treatment. The measurements of buccolingual inclinations of the upper central incisors and lower central incisors and the facial profile changes were made in cephalometric lateral radiographs. The width of the cusp tips and cervical intercanines, first and seconds premolars and first molars, had been gotten measuring the dental cast. All measurements were made at cephalometric lateral radiographs and dental cast obtained before orthodontic treatment (T1) and after treatment (T2). After collected all data was applied Student t test to compare the measures of the two times evaluated in this study. There was a statistically significant difference (p <0.05) in the inclination of lower central incisors and in the intertooth width of intercusp and intercervical of the first and second premolars and first molars in the maxilla. In the mandible all intertooth width (intercusp and intercervical) of canines, first and second premolars and first molars showed statistical significance (p <0.05), except the intercervical width of the lower canines. We concluded that the orthodontic treatment without extractions in patients with Class I malocclusion using Damon 2 brackets, standard prescription, did not promote change in the buccolingual inclination of upper central incisors, increased vestibular inclination of lower central incisors, did not change the facial profile and significantly increased the width of the maxilla and mandible by vestibular inclination of the crown.(AU) / Este trabalho teve como objetivo principal avaliar as inclinações dentárias e o perfil facial de pacientes tratados ortodonticamente com braquete autoligado Damon 2, prescrição padrão. Para este estudo, foi selecionada uma amostra de 18 indivíduos, sendo 12 do sexo masculino e 6 do feminino, com idades que variaram de 12 a 20 anos (idade média de 15 anos) e que apresentavam discrepância de modelo negativa (de 4 mm a 15 mm). Como critério de inclusão, os pacientes deveriam apresentar dentição permanente completa até os segundos molares, má oclusão de Classe I de Angle, telerradiografias em norma lateral do início e final do tratamento ortodôntico e modelos de estudo em gesso dos arcos dentários superiores e inferiores do início e final do tratamento ortodôntico. As medições das inclinações ântero-posteriores dos incisivos centrais superiores e incisivos centrais inferiores e alterações do perfil facial foram realizadas por meio das telerradiografias em norma lateral. As distâncias transversais das regiões de cúspide e cervical inter-caninos, primeiros e segundos pré-molares e primeiros molares, foram obtidas medindo-se os modelos de gesso. Todas as mensurações foram realizadas nas telerradiografias e modelos de gesso obtidos antes do início do tratamento ortodôntico (T1) e no final do tratamento (T2). Após a coleta de todos os dados aplicou-se o teste t de Student para comparar as medidas dos dois tempos avaliados neste estudo. Verificou-se diferença estatisticamente significante (p<0,05) na inclinação dos incisivos centrais inferiores e nas dimensões transversais inter-cúspides e inter-cervicais dos primeiros e segundos pré-molares e primeiros molares na maxila. Na mandíbula todas as distâncias transversais (inter cúspides e cervicais) de caninos, primeiros e segundos pré-molares e primeiros molares apresentaram significância estatística (p<0,05), exceto a distância inter-cervical dos caninos inferiores. Concluímos que o tratamento ortodôntico sem extrações de pacientes com má oclusão de Classe I realizados com os braquetes Damon 2, prescrição padrão, não promoveu alteração na inclinação vestíbulo-lingual dos incisivos centrais superiores, aumentou a inclinação vestibular dos incisivos centrais inferiores, não alterou o perfil facial e aumentou de modo significativo a dimensão transversal da maxila e da mandíbula por meio de inclinação vestibular de coroa.(AU)
15

Resistência de união, índice de remanescente adesivo e avaliação da presença de esmalte sobre a base de braquetes após descolagem: estudo in vitro

Tonetto, Mateus Rodrigues [UNESP] 31 January 2014 (has links) (PDF)
Made available in DSpace on 2015-03-03T11:52:20Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-01-31Bitstream added on 2015-03-03T12:07:30Z : No. of bitstreams: 1 000806368_20170131.pdf: 301415 bytes, checksum: d5befa6999fc213abc6df3b415c547ce (MD5) Bitstreams deleted on 2017-02-03T10:35:38Z: 000806368_20170131.pdf,. Added 1 bitstream(s) on 2017-02-03T10:36:28Z : No. of bitstreams: 1 000806368.pdf: 1361304 bytes, checksum: 376e0f7c264d2cb783ea56336927e782 (MD5) / Este estudo in vitro avaliou a resistência de união e índice de remanescente adesivo (IRA) de um braquete modificado colado com cimento resinoso auto-adesivo, e verificou a presença de substrato de esmalte na base do braquete após a descolagem. Foram selecionados noventa dentes bovinos e distribuidos aleatoriamente (n=15) de acordo com os grupos: G1 – Braquetes metálicos colados com Transbond™ XT; G2 – Braquetes metálicos do sistema APC colados sem procedimento adesivo adicional; G3 - Braquetes metálicos do sistema APC colados com sistema adesivo auto-condicionante; G4 - Braquetes metálicos colados com RelyX U200; G5 – Braquetes modificados (alteração na base do braquete Victory™) colados com Transbond™ XT; G6 - Braquetes modificados colados com RelyX U200. Foi realizado ensaio de resistência ao cisalhamento dos braquetes e após a remoção dos mesmos, o IRA foi observado em lupa estereoscópica (30x) (Carl Zeiss, Brasil) e as bases dos braquetes foram verificadas quanto a presença de resíduos de esmalte dental (Ca) por meio de EDS. Os resultados mostraram que o maior valor médio de resistência ao cisalhamento foi encontrado no grupo 1 (14,33 MPa) e o menor valor médio de resistência ao cisalhamento foi no grupo 4 (2,36 MPa). O IRA foi avaliado e os grupos que utilizaram o ácido fosfórico ou primer autocondicionante (grupos 1, 2, 3 e 5) apresentaram adesivo parcialmente e totalmente aderido ao dente. Quanto ao remanescente adesivo na base do braquete, o EDS identificou substratos de esmalte nos grupos 1 e 3 enquanto nos outros grupos verificou-se apenas remanescente adesivo sobre a base do braquete. Os resultados mostraram que os valores médio de resistência ao cisalhamento encontrados nos grupos de base modificada foram suficientes para suportar o tratamento ortodôntico. Após análise por EDS, concluiu-se que os braquetes modificados mostraram-se livres de fragmentos de esmalte, o que sugere a possível... / This study evaluated the bond strength of an experimental bracket bonded with selfadhesive resin cement, assessed the presence of enamel substrate on the bracket base after debonding and reviewed the possible methods to remove the remnant of enamel surface. Ninety bovine teeth were selected; the roots were sectioned and embedded in acrylic resin. The teeth were randomly assigned (n=15) according to the groups: G1 - metal brackets (Victory™) bonded with total etch adhesive system (Transbond™ XT), G2 - metal brackets APC (APC Plus System) without additional adhesive procedure; G3 - metal brackets APC (APC Plus system) bonded with selfetching adhesive system; G4 - metal brackets (Victory™) bonded with self-adhesive resin cement (RelyX U100); G5 - experimental brackets (modified on the Victory™ bracket basis) bonded with total etch adhesive system (Transbond™ XT); G6 - experimental brackets (modified on the Victory™ bracket basis) bonded with selfadhesive resin cement (RelyX U100) . Shear strength test of brackets was performed and after removal of the brackets, the adhesive remnant index (ARI) was observed in a stereomicroscope (30x) (Carl Zeiss, Brazil) and the bases of brackets were checked for the presence of enamel residues (Ca) by EDS . The results showed that the highest average value of shear strength was found in group 1 (14.33 MPa) and lower mean shear strength was in group 4 (2.36 MPa). Of the remaining adhesive on the bracket base EDS identified enamel substrates in groups 1 and 3, while the other groups there was only remaining adhesive on the bracket base. Therefore the experimental brackets are possible to be used in the future for orthodontics for showing lower risk of damage to the enamel.
16

Resistência de união, índice de remanescente adesivo e avaliação da presença de esmalte sobre a base de braquetes após descolagem : estudo in vitro /

Tonetto, Mateus Rodrigues. January 2014 (has links)
Orientador: Marcelo Ferrarezi de Andrade / Banca: Karina eiras Dela Coleta Pizzol / Banca: Flavia Magnani Bevilacqua / Banca: Andréa Abi Rached Dantas / Banca: Edson Alves de Campos / Resumo: Este estudo in vitro avaliou a resistência de união e índice de remanescente adesivo (IRA) de um braquete modificado colado com cimento resinoso auto-adesivo, e verificou a presença de substrato de esmalte na base do braquete após a descolagem. Foram selecionados noventa dentes bovinos e distribuidos aleatoriamente (n=15) de acordo com os grupos: G1 - Braquetes metálicos colados com Transbond™ XT; G2 - Braquetes metálicos do sistema APC colados sem procedimento adesivo adicional; G3 - Braquetes metálicos do sistema APC colados com sistema adesivo auto-condicionante; G4 - Braquetes metálicos colados com RelyX U200; G5 - Braquetes modificados (alteração na base do braquete Victory™) colados com Transbond™ XT; G6 - Braquetes modificados colados com RelyX U200. Foi realizado ensaio de resistência ao cisalhamento dos braquetes e após a remoção dos mesmos, o IRA foi observado em lupa estereoscópica (30x) (Carl Zeiss, Brasil) e as bases dos braquetes foram verificadas quanto a presença de resíduos de esmalte dental (Ca) por meio de EDS. Os resultados mostraram que o maior valor médio de resistência ao cisalhamento foi encontrado no grupo 1 (14,33 MPa) e o menor valor médio de resistência ao cisalhamento foi no grupo 4 (2,36 MPa). O IRA foi avaliado e os grupos que utilizaram o ácido fosfórico ou primer autocondicionante (grupos 1, 2, 3 e 5) apresentaram adesivo parcialmente e totalmente aderido ao dente. Quanto ao remanescente adesivo na base do braquete, o EDS identificou substratos de esmalte nos grupos 1 e 3 enquanto nos outros grupos verificou-se apenas remanescente adesivo sobre a base do braquete. Os resultados mostraram que os valores médio de resistência ao cisalhamento encontrados nos grupos de base modificada foram suficientes para suportar o tratamento ortodôntico. Após análise por EDS, concluiu-se que os braquetes modificados mostraram-se livres de fragmentos de esmalte, o que sugere a possível... / Abstract:This study evaluated the bond strength of an experimental bracket bonded with selfadhesive resin cement, assessed the presence of enamel substrate on the bracket base after debonding and reviewed the possible methods to remove the remnant of enamel surface. Ninety bovine teeth were selected; the roots were sectioned and embedded in acrylic resin. The teeth were randomly assigned (n=15) according to the groups: G1 - metal brackets (Victory™) bonded with total etch adhesive system (Transbond™ XT), G2 - metal brackets APC (APC Plus System) without additional adhesive procedure; G3 - metal brackets APC (APC Plus system) bonded with selfetching adhesive system; G4 - metal brackets (Victory™) bonded with self-adhesive resin cement (RelyX U100); G5 - experimental brackets (modified on the Victory™ bracket basis) bonded with total etch adhesive system (Transbond™ XT); G6 - experimental brackets (modified on the Victory™ bracket basis) bonded with selfadhesive resin cement (RelyX U100) . Shear strength test of brackets was performed and after removal of the brackets, the adhesive remnant index (ARI) was observed in a stereomicroscope (30x) (Carl Zeiss, Brazil) and the bases of brackets were checked for the presence of enamel residues (Ca) by EDS . The results showed that the highest average value of shear strength was found in group 1 (14.33 MPa) and lower mean shear strength was in group 4 (2.36 MPa). Of the remaining adhesive on the bracket base EDS identified enamel substrates in groups 1 and 3, while the other groups there was only remaining adhesive on the bracket base. Therefore the experimental brackets are possible to be used in the future for orthodontics for showing lower risk of damage to the enamel. / Doutor
17

Analise in vitro de diferentes metodos da remoção da resina residual no esmalte dentario / Evaluation in vitro different methods of dental enamel residual resin removal

Tavares, Stenyo Wanderley 20 June 2006 (has links)
Orientador: Simonides Consani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-07T04:24:28Z (GMT). No. of bitstreams: 1 Tavares_StenyoWanderley_D.pdf: 4135316 bytes, checksum: 2a1db19579aa0bcb7036ac454b9d537d (MD5) Previous issue date: 2006 / Resumo: O objetivo desta pesquisa foi comparar in vitro diferentes métodos de remoção da resina residual do esmalte dentário, após o descolamento de bráquetes. Cinquenta terceiros molares foram separados em 5 grupos (n=10). Foram fixados bráquetes metálicos com o compósito ortodôntico Transbond XT, após condicionamento do esmalte com ácido fosfórico a 37%. Os corpos-de-prova foram armazenados água à temperatura ambiente, por 24 horas. Após a remoção dos bráquetes com pistola removedora (Orthosource), a resina remanescente foi removida por diferentes tipos de tratamento: grupo I ¿ Jato de óxido de alumínio, grupo II ¿ ponta de carboneto de tungstênio (30 lâminas) em alta rotação; grupo III ¿ ponta de óxido de alumínio (Shofu) em alta rotação, grupo IV ¿ sistema Profin, grupo V ¿ alicate removedor de resina. Depois da remoção da resina foi realizado polimento com pasta de pedra pomes e água em todas as amostras. A avaliação foi realizada antes da colagem, depois da remoção e após o polimento, por meio da análise rugosimétrica de superfície e observação em microscopia eletrônica de varredurra. Os valores de rugosidade foram submetidos à análise de variância a ao teste de Tukey (5%). Os resultados demonstraram que em todas as fases, o alicate removedor de resina foi método que mostrou os melhores resultados. Depois da remoção da resina residual, os métodos com broca de carboneto de tungstênio (30 lâminas) e com ponta de óxido de alumínio mostraram os maiores valores de rugosidade com diferença estatística significante em relação aos demais. O polimento foi importante para o restabelecimento da lisura superficial do esmalte, em todos os métodos de remoção da resina residual / Abstract: The purpose of this study was to compare different in vivo methods of dental enamel residual resin removal after brackets debonding. Fifty third molars were separated in 5 groups of 10 teeth. Metal brackets were fixed with Transbond XT orthodontic composite, after enamel conditioning with 37% phosphoric acid. Specimens were stored in water at room temperature for 24 hours. After brackets debonding with a removal plier (Orthosource), residual resin was removed through different treatment methods: Group I- aluminium oxide blaster, group II ¿ high speed tungsten carbide bur (30 laminae), group V ¿ resin removal plier. After resin elimination it was accomplished pumice and water polishing in all specimens. Evaluation was consummated before bonding, after removal, and also after polishing, trrought roughness surface analysis and scanning electron microscopy observation. Roughness values were submitted to variance analysis and Tukey test (5%). Results showed that the removal method which did not present significant statistical difference in roughness surface enamel values in all treatment methods was resin removal plier. Polishing was important for enamel superficial smoothness recovery in all methods for removal residual resin / Doutorado / Ortodontia / Doutor em Radiologia Odontológica
18

Analise in vitro da resistencia ao cisalhamento de braquetes metalicos submetidos a reciclagem repetida : fixados com diferentes materiais

Lunardi, Nadia, 1976- 12 September 2004 (has links)
Orientadores: João Sarmento Pereira Neto, Simonides Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T04:19:16Z (GMT). No. of bitstreams: 1 Lunardi_Nadia_M.pdf: 1996088 bytes, checksum: 349b61cd35911f4191f9ad6dc0b13a3f (MD5) Previous issue date: 2004 / Resumo: O objetivo desta pesquisa foi avaliar in vitro a resistência ao cisalhamento de braquetes ortodônticos metálicos submetidos a duas reciclagens consecutivas com jato de óxido de alumínio, em função de quatro tipos diferentes de materiais fixadores. A amostra consistiu de 40 incisivos bovinos para confecção dos corpos-de-prova. Quarenta braquetes metálicos edgewise, de incisivo central Ultraminitrim (Dentaurum), foram colados nos dentes bovinos com os seguintes materiais fixadores: Transbond XT, Concise, Smartbond e Fuji Orto, seguindo as instruções do fabricante. Após a colagem os corpos-de-prova foram armazenados em água destilada numa estufa a 37ºC por 24 horas e submetidos à 500 ciclos térmicos com 30 segundos em cada balho (5ºC e 55ºC). O ensaio de resistência ao cisalhamento foi realizado numa máquina Instron com velocidade de 0,5mm/min. Os braquetes removidos foram reciclados com jateamento de óxido de alumínio (50 micrômetro) e colados novamente no mesmo corpo-de-prova, utilizando os mesmos materiais fixadores. Após o segundo ensaio de resistência ao cisalhamento, os procedimentos de reciclagem, recolagem e ensaio de força foram repetidos. Os dados foram submetidos à análise de variância e ao teste de Tukey (p=0.05), aplicado para cada sistema adesivo nos diferentes tratamentos dos braquetes metálicos. Foi comprovado que reciclagens repetidas, utilizando o jateamento de óxido de alumínio, não interferem na resistência adesiva, independente do sistema adesivo empregado. Dentre os adesivos utilizados, o Transbond XT apresentou os maiores valores de resistência ao cisalhamento, independente do tratamento do braquete. Assim, concluímos que o efeito cumulativo das reciclagens não afetou a resistência ao cisalhamento de braquetes metálicos e que o efeito adesivo do material utilizado para fixação do braquete não foi alterado pelas reciclagens repetidas / Abstract: The aim of this research was to evaluate in vitro shear bond strength of metallic orthodontic brackets submitted to two consecutive recyclings with aluminium oxide air abrasion, making use of four different bond materials. The sample consisted of 40 bovine incisives. Forty metallic orthodontic edgewise brackets of central incisor Ultraminitrim (Dentaurum), were fixed in the bovine teeth with the following bonded material: Transbond XT, Concise, Smartbond and Fuji Orto, following the manufacturer's instructions. After bonding, they were stored in distilled water in incubators at 37ºC for 24 hours and submitted to 500 thermal cycles with 30 seconds in each bath (5ºC and 55ºC). The shear bond strength was determined with an Instron universal machine with 0,5mm/min speed. The removed brackets were recycled with aluminium oxide air abrasion (50 micrometer) and bonded again in the same bovine incisive, using the same bond material. After the second shear bond strength test the recycling procedures, the rebonding and shear bond strength test were repeated. The data were submitted to Analysis of Variance and Tukey's test (p=0.05), applied for each adhesive system in different treatments of metallic brackets. It was demonstrated that repeated recyclings, using the aluminium oxide air abrasion, don't interfere in the adhesive resistance, independent of the employed bond material. Among the used bond materials, Transbond XT presented the largest resistance values of shear bond strength, independent of the treatment of the bracket. Thus, we concluded that the recycling cumulative effects didn't affect the shear bond strength of metallic orthodontic brackets and that the effect bond material used for fixation of the bracket was not altered by the repeated recyclings / Mestrado / Ortodontia / Mestre em Ortodontia
19

Avaliação de enxaguatório bucais na atividade biológica do biofilme formado em braquetes ortodônticos / Evaluation of oral Rinses in biological activity of biofilm formed in orthodontic brackets

Bussadori, Celene Marques 25 September 2013 (has links)
Na Odontologia, existe uma grande preocupação com a formação de placa bacteriana ou biofilme devido ao seu potencial cariogênico. Essa atenção se estende à ortodontia, devido ao acúmulo de biofilme formado nos aparelhos ortodônticos, tanto nos aparelhos removíveis quanto nos aparelhos fixos. É muito comum a presença de lesões brancas após a remoção dos bráquetes, em torno de 50 a 75% dos pacientes, provocadas pela presença do biofilme. É necessário um controle químico e mecânico rigoroso, a fim de se evitar alterações irreversíveis nos dentes e periodonto. O controle mecânico se dá pela escovação adequada, pelo correto uso de fio dental e pela frequência desses hábitos, além, claro, de um acompanhamento profissional periódico. O controle químico pode ser viabilizado pelo uso de enxaguatórios bucais, nos quais residem alguns efeitos indesejáveis e contraindicações relacionadas ao uso e à idade dos pacientes. Este estudo tem como objetivo avaliar comparativamente dois enxaguatórios bucais, um de natureza comercial (Cepacol®), e outro não comercial, elaborado com extratos hidroalcoólicos das plantas Nasturtium officinale (agrião), Rosmarinus offinalis (alecrim), Tabebuia impetiginosa (ipê roxo), Achillea millefolium (mil folhas) e Plantago major (tanchagem), desenvolvido na Faculdade de Ciências Farmacêuticas/UNESP Araraquara. Foram selecionados 40 pacientes, jovens e adultos, entre 18 e 45 anos, usuários de aparelho ortodôntico corretivo (fixo), divididos em dois grupos, o grupo do Cepacol e o grupo do Enxaguatório base de plantas. Foram coletadas amostras nos períodos de 0, 7, 15 e 21 dias e analisadas observando-se as Unidades Formadoras de Colônia (UFC) de cada amostra. Houve uma queda significativa da quantidade de bactérias após o uso do Enxaguatório à base de plantas, revelando um produto de extrema utilidade no auxílio do controle do biofilme bacteriano nas superfícies dentárias. / In dentistry, there is a great concern with the formation of plaque or biofilm, due to its cariogenic potential. This attention extends to orthodontics due to the accumulation of biofilm on orthodontic appliances, removable appliances as much in the brackets. It is very common the presence of white spots after removal of the brackets, around 50 to 75% of patients, which are caused by biofilms. It takes a rigorous mechanical and chemical control in order to avoid irreversible changes in the teeth and periodontium. The mechanical control is by proper brushing, correct flossing and also the frequency of these habits, besides, of course, a periodical professional monitoring. Chemical control can be achieved by the use of mouthwashes, home to some undesirable effects and contraindications related to the use and age of patients. This study aimed to assess two mouthwashes, a commercial type (Cepacol ®) and other non-commercial, made with hydroalcoholic extracts of plants Nasturtium officinale (watercress), offinalis Rosmarinus (rosemary), Tabebuia impetiginosa ( purple ipe), Achillea millefolium (thousand leaves) and Plantago major (plantain), developed at the Faculty of Pharmaceutical Sciences / UNESP Araraquara. We selected 40 patients, young and adults between 18 and 45 years, users of orthodontic appliance (fixed), divided into two groups, the Cepacol group and the group of herbal mouthwash. Samples were collected during periods of 0, 7,15 and 21 days and analyzed by observing the Colony Forming Units (CFU) of each sample. There was a significant decrease in the amount of bacteria after using herbal mouthwash, revealing a product of the utmost use in aiding the control of bacterial biofilms on tooth surfaces.
20

Preferência e percepção do desconforto por pacientes adultos submetidos a tratamento ortodôntico com bráquetes convencionais e autoligáveis : um estudo clínico randomizado split-mouth /

Shibasaki, Wendel Minoro Muniz January 2019 (has links)
Orientador: Renato Parsekian Martins / Resumo: Introdução: O ortodontista necessita ponderar entre a melhor evidência científica disponível, a sua experiência profissional e as preferências do paciente para a tomada de decisão clínica. A decisão entre bráquetes autoligáveis (BA) ou convencionais (BC) pode ser fundamentada com estudos comparando sua eficiência clínica e aspectos profissionais de manuseio dos bráquetes, mas poucos estudos abordam as percepções do paciente e nenhum compara e quantifica a preferência e a percepção de desconforto dos pacientes, distinguindo-a da sensibilidade dolorosa. Um estudo clínico randomizado e controlado split-mouth de centro único foi conduzido com esse objetivo. Métodos: Vinte e seis participantes com média de 28,8(11,5) anos, com má oclusão simétrica, foram convocados para participar da pesquisa. Cada paciente teve um hemiarco superior randomizado para instalação de BA, enquanto o hemiarco contralateral era instalado os BC, ao mesmo tempo (T0). O cegamento apenas foi possível para o pesquisador. A preferência foi consultada após 30 dias e quantificada pela técnica willigness-to-pay (WTP), enquanto o nível de desconforto foi medido por escala visual analógica (EVA) antes da instalação(T0), imediatamente após a instalação (T1), 7 dias após a instalação (T2) e 30 dias após a instalação e com fio amarrado (T3). Índices de placa (IP) e gengival(IG) foram feitos em T0 e T3. Resultados: Os pacientes percebem diferença entre os modelos usados. Ao final, 17 pacientes preferiram os bráquetes c... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: ABSTRACT Introduction: The orthodontist needs to balance between the best available scientific evidence, his professional experience and the patient's preferences for clinical decision-making. The decision between self-ligating (SLB) or conventional (CB) brackets can be based on studies comparing their clinical efficiency and professional aspects of bracket manipulation, but few studies address the patient's perceptions and none compares and quantifies preference and perception of discomfort of patients, distinguishing it from pain sensitivity. A single-center, randomized, controlled split-mouth trial was conducted with this goal. Methods: Twenty-six participants with a mean age of 28.8 (11.5) years with symmetric malocclusion were invited to participate in the study. Each patient had a superior hemiarch randomized to bonding SLB, while the contralateral hemiarch had CB bonded at the same time (T0). Blinding was only possible for the researcher. The preference was consulted after 30 days and quantified by the willigness-to-pay (WTP) technique, while the level of discomfort was measured by visual analogue scale (VAS) before bonding (T0), immediately after bonding (T1), 7 days after bonding (T2) and 30 days after bonding and with wire tied (T3). Plaque and gingival index were made in T0 and T3. Results: Patients perceive difference between the models used. In the end, 17 patients preferred the conventional, while 9 preferred the self-ligation brackets. Patients who chose CBs we... (Complete abstract click electronic access below) / Doutor

Page generated in 0.0562 seconds