Spelling suggestions: "subject:"braquetes ortodôntico"" "subject:"braquetes endodôntico""
41 |
Avaliação clinica e laboratorial da colagem de braquetes metalicos com compositos ortodonticos / Clinical and laboratory evaluation of metallic brackets bonded with orthodontic compositesRomano, Fabio Lourenço 13 August 2018 (has links)
Orientadores: Maria Beatriz Borges de Araujo Magnani, Lourenço Correr Sobrinho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T18:10:24Z (GMT). No. of bitstreams: 1
Romano_FabioLourenco_D.pdf: 2297898 bytes, checksum: 5ecd4de7f0dd31f6b954e634f32893ef (MD5)
Previous issue date: 2009 / Resumo: O objetivo neste estudo foi avaliar clinicamente e em laboratório, a taxa de descolagem e a resistência ao cisalhamento de bráquetes metálicos colados com compósitos ortodônticos. O experimento clínico consistiu de 20 pacientes (10,5-15,1 anos de idade), que procuraram tratamento ortodôntico corretivo. Nestes pacientes foram colados bráquetes de 2° pré-molar a 2° pré-molar no arco superior e inferior com os sistemas adesivos: Concise Ortodôntico, Transbond XT convencional, Transbond XT sem agente de união e Transbond XT em esmalte preparado com ácido-primer Transbond Plus Self Etching Primer (TPSEP). Todos os sistemas foram utilizados em todos os pacientes, em rodízio pelos quadrantes, sendo que, a mesma sequência de colagem se repetiu em cada cinco pacientes. Arcos iniciais foram inseridos uma semana após a colagem dos bráquetes. Os pacientes foram avaliados durante seis meses para quantificar o número de bráquetes descolados. Ao final do período de observação ocorreram 8 descolagens com Concise Ortodôntico, 2 com Transbond XT convencional, 9 com Transbond XT sem agente de união e 1 com TPSEP + Transbond XT. Pelo Método de Kaplan-Meier foram encontradas diferenças estatísticas significantes na taxa de descolagem entre os materiais (P=0,0198) e o teste Logrank identificou estas diferenças. O Transbond XT convencional e TPSEP + Transbond XT foram estatisticamente superiores (apresentaram menos descolagens) em relação ao Concise Ortodôntico e Transbond XT sem agente de união (P<0,05). Entre os materiais Transbond XT convencional e TPSEP + Transbond XT não foram encontradas diferenças estatísticas significantes, assim como, entre Concise Ortodôntico e Transbond XT sem agente de união (P>0,05). O experimento laboratorial teve como objetivo avaliar a resistência ao cisalhamento de bráquetes metálicos colados com o novo compósito ortodôntico Transbond Plus Color Change (TPCC, 3M Unitek) em diferentes preparações de esmalte e analisar após a descolagem o Índice de Remanescente de Adesivo (IRA). Foram utilizados 72 pré-molares humanos divididos em seis grupos (n=12). No Grupo 1 (controle) foi utilizado o compósito Transbond XT convencionalmente. Nos demais grupos (2 a 6) utilizou-se o TPCC nas seguintes condições de esmalte: ácido fosfórico e XT primer; ácido-primer TPSEP; somente ácido fosfórico; ácido fosfórico, XT primer e saliva; TPSEP e saliva, respectivamente. Após a colagem dos bráquetes e fotoativação, os corpos de prova foram armazenados em água destilada em estufa a 37°C por 24 horas. Em seguida, os bráquetes foram carregados em máquina Instron à velocidade de 0,5 mm/min. e o IRA avaliado em lupa estereoscópica. Osvalores médios de resistência ao cisalhamento (MPa) foram: Grupo 1- 24,6; Grupo 2-18,7; Grupo 3-17,5; Grupo 4-19,7; Grupo 5-17,5 e Grupo 6-14,8. Os dados foram submetidos à ANOVA e ao teste de Tukey (5%). O Grupo 1 apresentou maior média e diferiu estatisticamente dos grupos 3, 5 e 6 (P<0,05) e sem diferença estatística significante em relação aos grupos 2 e 4 (P>0,05). Entre os grupos 2, 3, 4, 5 e 6 não foram encontradas diferenças estatísticas significantes (P>0,05). A colagem de bráquetes com TPCC apresentou valores comparáveis ao Transbond XT convencional e o tipo de preparo de superfície não influenciou esta adesão / Abstract: The aim of this study was to assess clinically and laboratory the bracket failure rate and shear bond strength of metallic brackets bonded with orthodontic composites. The in vivo study consisted of 20 patients aged between 10.5 to 15.1 years old who had sought corrective orthodontic treatment. Brackets were bonded of the second premolar - second premolar to their upper and lower arches using the adhesive systems: Orthodontic Concise, conventional Transbond XT, Transbond XT without primer, and Transbond XT applied to enamel etched with Transbond Plus Self-etching Primer (TPSEP). All the adhesive systems were used in all patients on a quadrant-rotation basis by repeating the same bonding sequence in every 5 patients. Initial archwires were inserted a week after the brackets bonding. The patients were evaluated during six months in order to quantify the number of brackets failure regarding each adhesive system. At the end of the observation period, 8 brackets failure rates were observed for Orthodontic Concise, 2 for conventional Transbond XT, 9 for Transbond XT without primer, and
1 with Transbond XT + TPSEP. By using the Kaplan-Meier methods, statistically significant differences were found between the materials (p=.0198), and the Logrank test identified these differences. It was observed that conventional Transbond XT and Transbond XT + TPSEP were statistically superior (fewer debonded brackets) compared to Orthodontic Concise and Transbond XT without primer (P<.05). However, no statistically significant differences were found between conventional Transbond XT and TPSEP + Transbond XT as well as between Orthodontic Concise and Transbond XT without primer (P>.05). The in vitro study aimed at assessing the shear bond strength of metallic brackets bonded to different enamel surfaces using the Transbond Plus Color Change composite (TPCC, 3M Unitek) as well as to analyse the Adhesive Remnant Index (ARI). Seventy-two human premolars were used for study, with all samples being divided into six groups (n =12). In Group 1 (control), Transbond XT composite was conventionally used. In other groups (2-6), TPCC was used under the following enamel conditions: phosphoric acid and XT primer; TPSEP; phosphoric acid only; phosphoric acid, XT primer and saliva; and TPSEP and saliva, respectively. After bracket bonding and photo-activation, the samples were stored in distilled water for 24 hours at 37°C in a stove. Next, the brackets were debonded by using an Instron machine at crosshead speed of 0.5 mm/min, and the ARI were evaluated by using a stereoscopic magnifying glass. The mean shear strength values (MPa) were the following: Group 1, 24.6; Group 2, 18.7; Group 3, 17.5; Group 4, 19.7; Group 5, 17.5; and Group 6, 14.8. Data were submitted to both ANOVA and Tukey's test (5%). Group 1 was found to be statistically superior to Groups 3, 5, and 6 (P<.05), with no statistically significant difference compared to Groups 2 and 4 (P>.05). No statistically significant differences were found between Groups 2, 3, 4, 5 and 6 (P>.05). The bracket bonding using TPCC composite showed values comparable to the conventional Transbond XT, and the type of enamel preparation had no influence / Doutorado / Ortodontia / Doutor em Radiologia Odontológica
|
42 |
Laser de CO2 como auxiliar na remoção de bráquetes estéticos cerâmicos / CO2 laser-assisted debonding for esthetic ceramic bracketsRodrigo Teixeira Macri 02 May 2012 (has links)
Este estudo avaliou a eficiência do uso do laser de CO2 com comprimento de onda de 10,6 m como auxiliar na remoção de bráquetes estéticos cerâmicos. Para este estudo foram utilizados 105 pré-molares inferiores humanos recentemente extraídos, que receberam irradiações com laser de CO2 antes da descolagem dos bráquetes. Na primeira fase deste estudo, o objetivo foi mensurar e comparar a temperatura no compósito de colagem do bráquete e na câmara pulpar após aplicação do laser de CO2 , para observar a segurança para o esmalte, bem como se a temperatura era suficiente para fragilizar o compósito, facilitando a remoção do bráquete. Nesta etapa foram utilizados 30 pré-molares inferiores recentemente extraídos, sendo que cada um recebeu 4 irradiações com diferentes protocolos de maneira aleatória. Foram testados 12 diferentes protocolos variando o tempo de irradiação (3 e 5s), a duração do pulso (0,01 e 0,03s) e a potência (5, 8 e 10W). Cada protocolo foi utilizado por 10 vezes (n=10), totalizando 120 irradiações. Em todas as irradiações os corpos-de-prova foram imersos em banho térmico com água a 37º C. Foram encontrados 4 protocolos cuja variação da temperatura na polpa foi menor que 5,5º C, portanto compatível com a saúde da polpa. Na segunda etapa do estudo, o objetivo foi avaliar a resistência ao cisalhamento após a aplicação do laser utilizando os protocolos cuja temperatura na polpa não fosse superior a 5,5º C. Setenta e cinco pré-molares inferiores humanos foram divididos em 5 grupos, dos quais um não foi submetido à irradiação, sendo considerado Controle (C). Nos 4 grupos restantes, irradiações foram realizadas como descrito a seguir: Grupo I (potência 5W; tempo de pulso 0,01s; tempo de aplicação 3s), Grupo II (5W; 0,03s e 3s), Grupo III (8W; 0,01s e 3s) e Grupo IV (10W; 0,01s e 3s). Cada grupo foi formado por 15 corpos-de-prova (n=15). Após a descolagem do bráquete foi avaliado o Índice de Remanescente Adesivo (IRA). Após as mensurações e aplicação da Análise de Variância (ANOVA) e do teste de Tukey foi constatado que o único grupo que apresentou diminuição na força de remoção foi o IV (7,33 MPa) em relação ao grupo C (10,81 MPa) sendo assim considerado seguro e eficaz na diminuição da resistência do compósito. / This study evaluates the efficacy CO2 10,6 m laser-assisted debonding esthetic ceramic brackets. For this purpose it was used 105 recently extracted lower human premolars that were irradiated with CO2 laser before debonding. In the first phase, the objectives were to measure and compare the temperature in composite for bracket bonding and at the pulp chamber after CO2 laser irradiation, to observe the safety for enamel, as well the temperature was enough to softening the composite, making debonding bracket easier. In this part it was used 30 lower premolar recently extracted, and each one received 4 irradiations with different protocols, randomly choose. It was tested 12 different protocols varying time of irradiation (3 and 5s), pulse duration (0,01s e 0,03s) and power (5, 8 and 10W). Each protocol was repeated for 10 times (n=10), resulting 120 irradiations. In every irradiation the teeth tested were immerse in warm water bath at 37o C. It was found 4 protocols with pulp temperature lower than 5,5º C, so this is compatible with pulp health. In the second phase of this study, the objective was to evaluate the shear bond strength after laser irradiation, using the protocols with pulp chamber temperatures lower than 5,5º C. Seventy-five lower human premolars was shared in 5 groups. One group did not receive laser irradiation and considered Control (C) and the other groups the irradiation was made as it follows: Group I (power density 5W; pulse duration 0,01s; irradiation time 3s), Group II (5W; 0,03s, 3s), Group III (8W; 0,01s; 3s) and Group IV (10W; 0,01s; 3s). After results ANOVA and Tukey tests were made. Group IV presented lowering in SBS force (7,33 MPa) when compared with C (10,81MPa). This protocol was founded as a safe and efficient in softening composite layer.
|
43 |
Desenvolvimento de um dispositivo posicionador de acessórios ortodônticos com precisão verticalMota Júnior, Sergio Luiz 29 March 2016 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-07-26T14:40:46Z
No. of bitstreams: 1
sergioluizmotajunior.pdf: 31675383 bytes, checksum: 4a7f6f6e29158d411892c2d4acac4c92 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-07-27T11:29:40Z (GMT) No. of bitstreams: 1
sergioluizmotajunior.pdf: 31675383 bytes, checksum: 4a7f6f6e29158d411892c2d4acac4c92 (MD5) / Made available in DSpace on 2016-07-27T11:29:40Z (GMT). No. of bitstreams: 1
sergioluizmotajunior.pdf: 31675383 bytes, checksum: 4a7f6f6e29158d411892c2d4acac4c92 (MD5)
Previous issue date: 2016-03-29 / FAPEMIG - Fundação de Amparo à Pesquisa do Estado de Minas Gerais / O correto posicionamento dos bráquetes é importante para garantir o alinhamento e nivelamento dos dentes durante o tratamento ortodôntico. Há instrumentos posicionadores que são utilizados para determinar a posição vertical adequada dos acessórios na superfície dentária. Mesmo estes instrumentos são passíveis de erros durante sua utilização, por permitirem a inclinação vestíbulo-lingual, levando os bráquetes a uma posição inadequada. Prejudicam todo o tratamento, e causam problemas dentários individuais como: alteração do comprimento do arco dentário; provocam intrusões, extrusões, contatos pré-maturos e; consequentemente comprometem todo o sistema mastigatório. Baseado nesta limitação dos instrumentos posicionadores verticais atualmente disponíveis no mercado, o objetivo deste estudo foi descrever o desenvolvimento, apresentar e testar um posicionador do tipo estrela que impeça a inclinação vestíbulo-lingual durante o seu uso. O instrumento foi criado, modelado, patenteado e prototipado para os testes laboratoriais. Para os testes, foram formados quatro grupos com diferentes tempos de experiência clínica em Ortodontia, composto por seis participantes em cada grupo. Cada indivíduo colou bráquetes edgewise 0,022”x0,028” em um manequim typodont com maloclusão Classe I em incisivos, caninos e pré-molares superiores e inferiores. Eles utilizaram primeiramente a estrela de Boone e posteriormente a Estrela UFJF (houve pelo menos 30 dias de diferença entre as colagens). Os estudos mostraram que o uso da Estrela UFJF propiciou médias de colagem mais próximas à considerada ideal no presente estudo (4mm) nos grupos que apresentavam alguma experiência em Ortodontia. Nos grupos de dentes avaliados, o desvio padrão em relação 4mm foi menor quando utilizada a Estrela UFJF se comparado ao uso da estrela de Boone. Todos experimentos apresentaram menores variâncias quando utilizada a Estrela UFJF. Conclui-se, desta forma, que o instrumento desenvolvido apresentou menores variações no posicionamento vertical dos bráquetes ortodônticos quando associado à experiência clínica, sendo esta necessária para seu uso. / The bracket placement is important for the appropriate teeth alignment and leveling during orthodontic treatment. Instruments can be used to determine the position of vertical attachments at dental surface. They are prone to fail during their use because they allow buccolingual inclination and take wrong position of attachments. It may jeopardize a treatment, causing to individuals severe dental problems, such as change the length of the dental arch, intrusions, extrusions, premature contacts and even commit all estomatognatic system. Based on the vertical limitation of some instruments positioners, the aim of this study was to develop and test a star-like positioner that prevents a buccolingual inclination during its use. The instrument was created, modeled, patented and prototyped for laboratory tests. For analysis, 4 groups were defined with different clinical experience in orthodontics, with 6 participants in each group. Each individual bonded edgewise 0.022x0,028in brackets in a typodont with Class I malocclusion in maxillary and mandibular incisors, canines and premolars, first with a Boone gauge and at least 30-days after, with Estrela UFJF. Studies showed that Estrela UFJF had averages closer to the ideal (4mm) in groups with some experience in orthodontics than Boone gauge. In all groups available, the standard deviation was lower with the Estrela UFJF than with Boone gauge. Specific groups of teeth, which variances were lower with Estrela UFJF than with Boone gauge. It is concluded that the developed instrument presented less variations in bracket vertical positioning and some clinical orthodontic experience is necessary to its use.
|
44 |
Estudo comparativo in vivo e in vitro da resistência ao cisalhamento de braquetes metálicos colador com resina polimerizada com luz halógena e LEd /Penido, Sérgio Milton Martins de Oliveira. January 2006 (has links)
Orientador: Ary dos Santos-Pinto / Banca: Vânia Célia Vieira de Siqueira / Banca: Rodrigo de Castro Albuquerque / Banca: Lídia Parsekian Martins / Banca: Luiz Gonzaga Gandini Júnior / Resumo: Este trabalho teve como objetivo avaliar a resistência ao cisalhamento, in vivo e in vitro, de braquetes metálicos (Abzil Lancer) colados em dentes humanos com material adesivo polimerizado xom luz halógena e LED. Os braquetes foram cotados em 60 pré-molares formando seis grupos. Nos Grupos I e II os braquetes foram colados nos segundos pré-molares respectivamente no lado direito e esquerdo dos pacientes. A polimerização do material adesivo foi com a luz de LED epara o GI e luz halógena para o GII. Nos demais grupos os braquetes foram colados em primeiros pré-molaressuperiores e inferiores extraídos por motivos ortodônticos. A polimerização realizada nos grupos III e V foi com o aparelho de LED enquanto que nos grupos III e V foi com o aparelho de LED enquanto que nos grupos IV e VI com luz halógena. Nos Grupos I e II testes de cisalhamento foram realizados utilizando-se dinamômetro sigital portátil diretamente na boca dos pacientes. Os grupos IIII, IV, V e VI foram armazenados em água destilada e levados a estufa a 37ºC por 24 horas e posteriormente, submetidos a termociclagem, com 1000 ciclos a 5 e 55ºC. Posteriormente, nos grupos III e IV, utilizou-se máquina universal de ensaios mecânicos e nos grupos IV e VI os ensaios mecânicos foram realizados com dinamômetro digital. Os valores médios da resistência ao cisalhamento em Mpa foram de: GI = 3,65; GII = 4,39; GIII = 6,45; GIV = 7,11; GV = 4,67; GVI = 4,21. Após a descolagem foram realizadas fotografias Das áreas de colagem. As imagens obtidas foram ampliadas %x, analisadas e classificadas de acorso com o índice de Adesivo Remanescente (IAR). Os resultados dos testes mecânicos in vivo ou in vitro. Os testes realizados com equipamento portátil digital tiveram valores médios significativamente menores em relação áqueles realizados em máquina de ensaios mecânicos universal. Não houve relação definida entre carga de ruptura e tipo de falha. / Abstract: This work as a purpose to assess the shear bond strength, in vivo and in vitro , of metallic brackets (Abzil lancer) bondedto human teeth with light-curing bonding material with halogen and led lights. The brackets were bonded to 60 premolars, so forming 6 groups.In GI and II the brackets were bonded to second premolars, resectively, on the right and left sides of the patients. The polymerization of the bonding material was with LED light for GI and halogen light for GII. In the other groups the brackets were bonded to superior and inferior first premolars, extrated for orthodontic reasons. The polymerizatio was performed in GII and V with LED device, while in GIV and VI eith halogen light. In GI and II shear strength tests were made using a portable digital dynamoter directly in the patients' mouths. GII, IV, V and VI were stored in distilled water and taken to sterilizer at 37ºC for 24 hours, and afterwards, submitted to thermocycling with 1000 cycles at 5 and 55 º. Then, in GIII and IV, the Universal testing machine was used and in GIV and VI the mechanical tests were performed with a digital dynamometer. The average values of shear strength in Mpa were: GI=3,65; GII=4,39; GIII=6,45; GIV=7,11; GV=4,67 and GVI=4,21. Pictures of thebonding areas were taken after the tests. The images obtained amplified 5 times, analyzed and classified, according to Adhesive remaining index (IAR). The results suggested that the LED light or the halogen light did not interfere in the results of the mechanical tests in vivo or in vitro. The tests performed with a portable digital device obtained average values significantly lower than those performed with Universal testing machine. There was no definite relation between shear bond strengths and kind of failure. / Doutor
|
45 |
Análise comparativa in vitro da resistência friccional entre braquetes metálicos e estéticos / Friction resistance among stainless steel brackets and aesthetic brackets: an in vitro studyRodrigues, Kelly Regina Thomé Portugal 04 October 2011 (has links)
Made available in DSpace on 2016-08-03T16:30:57Z (GMT). No. of bitstreams: 1
RESUMO - Kelly Portugal Rodrigues.pdf: 90584 bytes, checksum: a9009d09309f76e094fc03b33ceabe30 (MD5)
Previous issue date: 2011-10-04 / The aim of this in vitro study was to compare the friction resistance among conventional and aesthetic orthodontic brackets with metal and vitreous slot with round and rectangular wires of different sections, simulating some situations without wire displacement, 2 mm of displacement and binding of 3o. A group of 125 brackets from 5 brands (Roth Standard, Composite, Elation, Invu and Radiance) was tested, 25 brackets for each brand. Five brackets were set on a device in order to simulate a top right hemi-arch (lateral and central incisors, canine, first and second premolars) and after that, the device was coupled on an universal testing machine EMIC DL2000. The archwires 0.016 , 0.018 and 0.017 x 0.025 NiTi were used on the no displacement and 2 mm displacement tests, while the wires 0.017 x 0.025 , 0.019 x 0.025 and 0.021 x 0.025 stainless steel were used to simulate the binding effect. Variance analysis and Tukey tests (p<0,05) were run to compare brackets with different archwires sizes and angulation. The study demonstrated that the polycarbonate aesthetic bracket Composite had the least friction in all archwires sizes tested. On the other hand, the monocrystalline ceramic bracket Radiance showed the greatest frictional resistance on the tests without wire displacement. Studies with archwire displacement and binding showed a statistically significant difference between the five accessories, of which Composite, Roth Standard, Elation, Invu and Radiance produced the highest friction resistance, in increasing order. Moreover, the insertion of a metal slot in the polycarbonate bracket Elation significantly reduced the friction. However, these friction was greater than the one from a metal bracket. To sum up, the insertion of a vitreous slot in the polycrystalline ceramic bracket Invu offered a greater surface smoothness, reducing consequently the friction and favoring the displacement. / O presente estudo visou comparar in vitro o atrito produzido por braquetes convencionais metálicos e estéticos com canaleta metálica e vítrea quando inseridos fios de secções redonda e retangular de diferentes dimensões, simulando situações sem deslocamento, com deslocamento de 2 mm e com simulação do efeito binding 3º. Foram utilizados 125 braquetes de 5 marcas comerciais (Roth Standard, Composite, Elation, Invu e Radiance), sendo 25 braquetes para cada corpo de prova. Para os ensaios laboratoriais, foram colados 5 braquetes simulando uma hemi-arcada superior direita (incisivos central e lateral, canino, primeiro e segundo premolares) em um dispositivo para posicionamento dos braquetes, sendo este acoplado à máquina universal de ensaios EMIC DL2000. Foram empregados os fios 0,016 , 0,018 e 0,017 x 0,025 NiTi para realização dos ensaios sem deslocamento e com deslocamento de 2 mm e os fios de secção 0,017 x 0,025 , 0,019 x 0,025 e 0,021 x 0,025 CrNi para realização dos ensaios com angulação zero grau e 3º. Para a comparação entre os braquetes nos diferentes fios e angulações, foi utilizada a Análise de Variância e o teste de Tukey (p<0,05). Os resultados demonstraram que nos ensaios sem deslocamento o braquete estético de policarbonato Composite apresentou menor atrito em todos os fios avaliados, enquanto o maior atrito em todas as combinações realizadas foi observado no braquete estético cerâmico monocristalino Radiance em relação aos demais braquetes. Nos ensaios com deslocamento de 2 mm e simulação do efeito binding 3º, os resultados foram semelhantes aos observados nos ensaios sem deslocamento. Contudo, houve uma diferença estatisticamente significante entre os cinco corpos de prova, sendo o atrito verificado, respectivamente e de forma crescente, nos braquetes Composite, Roth Standard, Elation, Invu e Radiance. Pôde-se concluir que a resistência friccional teve influência da composição dos braquetes, diâmetro dos fios e tipo de ensaio realizado (deslocamento de 2 mm e angulação de 3º). Além disso, a inserção da canaleta metálica no braquete estético de policarbonato Elation reduziu de forma estatisticamente significante o atrito, porém esse foi maior do que o gerado por um braquete convencional metálico e, por fim, a incorporação da canaleta vítrea no braquete estético cerâmico policristalino Invu ofereceu uma maior lisura de superfície, reduzindo as irregularidades e imperfeições presentes na canaleta o que levou, consequentemente, a uma redução estatisticamente significante no atrito, o que demonstra que a modificação em sua canaleta favoreceu o deslocamento e reduziu de forma efetiva essa resistência à fricção.
|
46 |
ANÁLISE DA INTEGRIDADE DO ESMALTE DENTÁRIO PÓS-REMOÇÃO DO REMANESCENTE RESIDUAL ORTODÔNTICO / ANALYSIS OF THE INTEGRITY OF DENTAL ENAMEL AFTER ORTHODONTIC RESIDUAL REMNANT REMOVALDegrazia, Felipe Weidenbach 01 September 2012 (has links)
The integrity of enamel has attracted attention of researches. Structural modifications could lead to higher bacterial retention and light reflection changes, and there the need to restore dental enamel to conditions closer to its initial state after bonding and debonding orthodontic procedures. The aim of this work was to determine and compare roughness parameters and appearance of the enamel after remnant adhesive removal, and evaluate time required for the different methods. Sixty one healthy human premolars extracted for orthodontic reasons were used, and 60 of them were examined with a profilometry analysis of surface roughness into two axes, horizontal (X) and vertical (Y). Performed this step, the specimens were submitted to bracket bonding procedure with phosphoric acid conditioning, washed and dried, a thin layer of adhesive system and light curing. After bracket debonding the specimens were randomly divided by removal method into: group 1 (control) - tungsten carbide tip (5 blades), at high speed, group 2 - tungsten carbide tip (30 blades), at high speed, and group 3 - a diamond chemical vapor deposition with ultrasound. The removal time of each remnant was recorded in seconds, and all procedure occurred under light reflector, simulating the clinical management. Thus, the samples were again submitted to profilometry analysis. Two images were obtained with 20x and 100x increase in scanning electron microscopy (SEM) of one specimen per group, chosen randomly, and one specimen that had not had its roughness evaluated, forming the Healthy group. The images were scored by two calibrated observers, such as: score 0 - perfect surface, score 1 - acceptable surface, score 2 - imperfect surface, and score 3 - unacceptable surface. Comparing roughness with intact enamel, generally, in X axis, all roughness parameters increased after the three methods, with exception of Rku and Rsk parameters. And generally, in Y axis, Ra, Rz, and Rz parameters decreased after removal in groups 1 and 2 and increased after group 3. Comparing each group after removal, in X axis, the first group showed the lowest roughness values and group 3 the largest and, in Y axis, the second group had the lowest values of Ra, Rq and Rz and group 3 the lowest values of Rku and Rsk parameters. The images were classified as Healthy Group - score 0, Group 1 - score 1, Group 2 - score 2 and Group 3 score 3. A significant increase in time removal occurred in group 1 relative to group 3. Thus, no cleanup procedures restore the enamel roughness to its original surface in all groups. The slowest procedure was performed with tungsten carbide 5 blades group. / A integridade do esmalte tem atraído a atenção de pesquisas, pois sua modificação poderá gerar maior retenção bacteriana e alterar a reflexão luminosa do esmalte, além de haver a necessidade de restituir o esmalte dentário às condições mais próximas ao seu estado inicial, após os procedimentos de colagem e descolagem ortodôntica. Este trabalho teve como objetivo determinar e comparar os parâmetros de rugosidade e aspecto do esmalte dentário após a remoção do remanescente resinoso, e do tempo despendido pelos diferentes métodos. Para isso, foram utilizados 61 pré-molares humanos hígidos, extraídos por razões ortodônticas, sendo que 60 pré-molares foram submetidos à análise prévia de rugosidade por perfilometria de superfície em dois eixos, horizontal (X) e vertical (Y). Realizada esta etapa, os espécimes foram submetidos aos procedimentos de colagem de bráquetes com condicionamento ácido, lavagem e secagem, aplicação de adesivo e fotoativação. Após a descolagem dos bráquetes, os espécimes foram divididos quanto ao método de remoção do remanescente residual em: grupo 1 (controle) ponta de carboneto de tungstênio (5 lâminas), em alta rotação; grupo 2 ponta de carboneto de tungstênio (30 lâminas), em alta rotação; e, grupo 3 ponta diamantada por deposição química, em ultrassom. O tempo de remoção de cada remanescente foi registrado, em segundos, para posterior comparação até a sua completa remoção, que ocorreu sob luz de refletor odontológico, simulando a conduta clínica. Após, os corpos de prova foram novamente submetidos à análise perfilométrica para obtenção de diferentes parâmetros de rugosidade do esmalte dentário. Foram obtidas duas imagens, com aumento de 20x e 100x em microscopia eletrônica de varredura (MEV), de um espécime por grupo, escolhido aleatoriamente, e mais um espécime que não teve a sua rugosidade avaliada, formando o grupo Hígido. As imagens foram classificadas, por dois observadores calibrados, como: escore 0 superfície perfeita; escore 1 superfície aceitável; escore 2 superfície imperfeita; e escore 3 superfície inaceitável. Foi encontrado no eixo X, aumento da rugosidade após os 3 métodos testados, com exceção do parâmetro Rsk. No eixo Y, houve diminuição da rugosidade nos grupos 1 e 2, com exceção dos parâmetros Rku e Rsk e no grupo 3 houve aumentou da rugosidade, com exceção do parâmetro Rsk. No eixo X, o grupo 1 apresentou os menores valores de rugosidade e o grupo 3, os maiores e no eixo Y, o grupo 2 apresentou os menores valores de rugosidade nos parâmetros Ra, Rq e Rz e o grupo 3 os menores valores nos parâmetros Rku e Rsk. As imagens foram classificadas como: Grupo Hígido escore 0; Grupo 1 escore 1; Grupo 2 escore 2; Grupo 3 escore 3. Houve aumento significativo no tempo de remoção do grupo 1 em relação ao grupo 3. Dessa maneira, não houve restituição das condições originais do esmalte após a remoção do remanescente resinoso em todos os grupos e o grupo 1 apresentou aumento no tempo de remoção do remanescente resinoso.
|
47 |
Estudo da resistência às forças de cisalhamento de três sistemas condicionantes indicados para a colagem de acessórios ortodônticosBertoz, André Pinheiro de Magalhães [UNESP] January 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:55Z (GMT). No. of bitstreams: 0
Previous issue date: 2004Bitstream added on 2014-06-13T20:36:31Z : No. of bitstreams: 1
bertoz_apm_me_araca.pdf: 3969582 bytes, checksum: bceb452a18ac260c5d9321687a89fc4b (MD5) / Os recentes materiais de colagem dos acessórios ortodônticos têm visado reduzir o tempo de trabalho do clínico, simplificando o procedimento do condicionamento ácido por meio dos sistemas adesivos autocondicionantes. Todavia, as qualidades adesivas desses materiais ainda demandam ser avaliada. Assim, o presente estudo objetivou avaliar a resistência às forças de compressão de três sistemas adesivos. Cento e oitenta incisivos inferiores bovinos foram seccionados e incluídos em matrizes de resina acrílica, nos quais acessórios ortodônticos foram colados com os sistemas Transbond XT (2 grupos de 30), Transbond XT Plus Self Etching Primer (2 grupos de 30) e Tyrian (2 grupos de 30). Para cada sistema, os testes de resistência foram realizados imediatamente (30 dentes) e 24 horas (30 dentes) após a colagem, em uma máquina de ensaio Versat 2000 (Pantec), utilizando célula de carga de 500 Kgf com uma velocidade de 1mm/minuto, de acordo com a literatura. Os sistemas convencional Transbond XT, Transbond XT Self Etching Primer e Tyrian apresentaram, respectivamente, valor médio de resistência à compressão de 7,43, 7,09 e 3,41 MPa no tempo imediatamente após a colagem, e 7,42, 8,81, 5,35 MPa no tempo 24 horas após a colagem, sendo as diferenças estatísticas significantes ao nível de 5% entre os grupos Tyrian e Transbond para ambos os tempos de estudo. Concluiu-se que o material Tyrian apresentou resistência à compressão significativamente inferior em relação aos grupos Transbond que foram similares. / Recent orthodontic bonding materials have aimed to reduce the working time of the clinician, by simplifying the acid etching procedure by applying self-etching primer adhesive systems. However, the adhesion quality of these materials still demands investigation. Thus, the present study aimed to evaluate the bond strengths of three different adhesive systems. A hundred and eighty bovine lower incisors were cut and embebbed in acrylic resin matrices, in which orthodontic brackets were bonded with Transbond XT (2n = 60), Transbond XT Self Etching Primer (2n = 60) e Tyrian (2n = 60). For each composite, bond strength tests were executed immediately (n = 30) and 24 hours (n = 30) after the bonding, in the assay machine Versat 2000 (Pantec), by applying 500 Kgf of load at 1mm/min of velocity. Transbond XT, Transbond XT Self Etching Primer and Tyrian presented, respectively, average values of bond strength of 7.43, 7.09 and 3.41 MPa at the time immediately, and 7.42, 8.81 and 5.35 MPa at 24 hours after the bonding, where differences were statistically significant at 5% between Tyrian and Transbond groups at both observation times. It was concluded that Tyrian was the material that presented significant lower bond strength with regard to Transbond groups that were similar.
|
48 |
Adição de monômero com função quaternária de amônio em adesivos experimentais para colagem de bráquetes metálicos : desenvolvimento de lesão cariosa e resistência de união após desafio cariogênicoNascimento, Patrícia Layane de Menezes Macêdo 03 February 2016 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Incipient carious lesions manifested by white spots are frequently visualized around the orthodontic brackets. Further to possible progression of these lesions to cavities, a reduction on the bond strength of the bracket to the tooth enamel might occur due to mineral loss. Adhesive systems containing monomers that inhibits the bacteria adhesion or activity have been developed to help at caries control around of brackets. This study evaluated the caries inhibition and shear bond strength reached by addition of antibacterial monomer 2-(Methacryloyloxy)ethyl]trimethylammonium chloride (MADQUAT) to adhesive used to cement orthodontic brackets when submitted to cariogenic challenge. Sound premolars were sectioned in halves and brackets are cemented to the buccal and lingual surfaces using experimental adhesives with 0 (control), 5 or 10% of MADQUAT. Half of the samples was subjected to cariogenic challenge using a microcosm biofilm model with intermittent exposure to sucrose for 6 hours per day during 5 days. Following, the samples were embedded in resin cylinders and brackets submitted to shear loading until the de-bonding. The mode failure was analyzed under optical microscopy. The tested samples were sectioned and the internal enamel hardness measured to calculate the integrated mineral loss (ΔS). Data of bond strength and ΔS were submitted to two-way ANOVA and Tukey test, while the chi-square test was used to assess the effect of factors on failure mode (α = 0.05). The adhesive containing 10% of MADQUAT significantly reduced the demineralization around the bracket, but also reached lowest bond strength values. No effect on the bond strength and ΔS was observed by addition of 5% MADQUAT to adhesive. The cariogenic challenge did not affect the bond strength and the failure mode, which was influenced only by the adhesive. It was concluded that the MADQUAT was only effective to reduce demineralization when added to the adhesive at a concentration of 10%, whereas this concentration also reduced the bond strength. / Lesões cariosas incipientes, manifestadas por meio de manchas brancas, são comumente visualizadas ao redor dos bráquetes. Além destas lesões poderem progredir para cavidades, uma redução na resistência de união do bráquete ao esmalte dental pode ocorrer devido à perda mineral. Sistemas adesivos contendo monômeros que inibem a adesão ou atividade bacteriana têm sido desenvolvidos para auxiliar no controle de cárie ao redor dos bráquetes. Este estudo avaliou a inibição de cárie e a resistência de união alcançado pela adição do monômero antibacteriano [2 - (metacriloxi) etil] trimetil cloreto de amônio (MADQUAT) ao adesivo usado para colagem de bráquetes ortodônticos quando submetidos ao desafio cariogênico. Para isto, foram utilizados trinta pré-molares hígidos, seccionados ao meio. Bráquetes foram colados nas faces vestibular e lingual usando adesivos experimentais com 0% (controle), 5% ou 10% de MADQUAT. Metade das amostras foram submetidas ao desafio cariogênico em modelo de biofilme com microcosmos, com exposição intermitente a sacarose por 6 horas por dia, durante 5 dias. Em seguida, as amostras foram embutidas em cilindros de resina e os bráquetes submetidos ao carregamento de cisalhamento até ruptura. O padrão de falha foi analisado em microscopia óptica. As amostras ensaiadas foram seccionadas ao meio e a dureza interna do esmalte mensurada para calcular a perda mineral integrada (ΔS). Os dados de resistência de união e ΔS foram submetidos à ANOVA de duas vias e teste de Tukey, enquanto queo teste Qui-quadrado foi usado para avaliar o efeito dos fatores no padrão de falha (α = 0,05). O adesivo contendo 10% de MADQUAT reduziu significativamente a desmineralização ao redor do bráquete, porém alcançou menores valores de resistência de união. Nenhum efeito na resistência de união e na ΔS foi observado com a adição de 5% de MADQUAT ao adesivo. O desafio cariogênico não afetou a resistência de união e o padrão de falha, o qual foi influenciado pelo adesivo. Concluiu-se que o MADQUAT apenas foi eficaz na redução da desmineralização quando adicionado ao adesivo para uma concentração de 10%, mas esta concentração também reduziu a resistência de união.
|
49 |
Resistência ao cisalhamento de bráquetes ortodônticos em esmalte bovino : comparação entre dois protocolos de desafio erosivoSantos, Catielma Nascimento 05 November 2015 (has links)
Dental erosion is a process of wear of the enamel surface, which may be caused by the
low pH present in acidic foods and beverages. Changing the tooth surface may influence
the bond strength of brackets during the orthodontic treatment. Thus, this study
evaluated two erosive challenge protocols from the bond strength of metal orthodontic
brackets after changes in bovine enamel due to two acidic drinks. This is an
experimental study, in vitro, using 60 bovine incisors. The sample was randomly
divided into six groups: G1 (artificial saliva - 7 days); G2 (Coca-Cola® - 7 days); G3
(Lemon juice - 7 days); G4 (artificial saliva - 30 days); G5 (Coca-Cola® - 30 days); G6
(Lemon juice - 30 days). Initially, it was performed the analysis of dental Knoop
microhardness to verify the standardization of the samples. Then, the immersion of the
specimens was performed in the drinks, following the prescribed protocols. Finishing
the erosive protocol, the metal brackets were cemented and, 48 hours later, the
resistance was evaluated through the shear test. For statistical analysis of the data, we
used the ANOVA test of two factors (solution factor and period of the treatment factor)
followed by Tuckey's Post Hoc and the T Test of Student for paired samples, all with α
= 5%. The sample presented normal distribution according to the Kolmogorov-Smirnov
test (p= 0,77). The mean and the standard deviation of the microhardness of the total
samples were 281,89 ± 44,51 KHN. There was no statistically significant difference in
shear strength to the period of treatment factor (seven or 30 days F5,54= 0,105; p=
0,901), however, there were statistically significant differences for the solution factor
(F5,54= 6,671; p= 0,003). The Tukey's Post Hoc test found that these differences
occurred between Saliva x Coca-Cola® solutions (p= 0,003) and Coca-Cola® x Lemon
juice (p= 0,029). When comparing if the treatment period would be significant for the
shearing results in each solution, the T test did not show any influence of the period to
any solution used. When comparing if the treatment time it would be significant for the
shearing results in each solution, the T test did not show any influence of the time to
any solution used. It is concluded that the period of the protocol used does not influence
the bond strength of the bracket to the tooth, but, regarding the immersion substances,
Coca-Cola® presented higher shear strength values. / A erosão dental é um processo de desgaste da superfície do esmalte que pode ser
provocado pelo baixo pH presente em alimentos e bebidas ácidas. A alteração da
superfície dental pode influenciar na resistência adesiva de bráquetes durante o
tratamento ortodôntico. Desta forma, este trabalho avaliou dois protocolos de desafio
erosivo a partir da resistência adesiva de bráquetes ortodônticos metálicos após
alterações provocadas em esmalte bovino por duas bebidas ácidas. Trata-se de um
estudo experimental, in vitro, utilizando 60 incisivos bovinos. A amostra foi dividida
aleatoriamente em seis grupos: G1 (saliva artificial - 7 dias); G2 (Coca-Cola® - 7 dias);
G3 (Suco de limão - 7 dias); G4 (saliva artificial - 30 dias); G5 (Coca-Cola® - 30 dias);
G6 (Suco de limão - 30 dias). Inicialmente, foi realizada a análise da microdureza dental
Knoop para verificar a padronização das amostras. Em seguida, foi realizada a imersão
dos corpos de prova nas bebidas seguindo os protocolos estipulados. Finalizando o
protocolo erosivo, os bráquetes metálicos foram cimentados e 48 horas depois foi
avaliada a resistência por meio do teste de cisalhamento. Para análise estatística dos
dados foi utilizado o Teste ANOVA de dois fatores (fator solução e fator tempo de
tratamento) seguido do Post Hoc de Tukey e o Teste T de Student para amostras
pareadas, todos com α= 5%. A amostra apresentou distribuição normal segundo o teste
de Kolmogorov-Smirnov (p= 0,77). A média e desvio padrão da microdureza das
amostras totais foram 281,89 ± 44,51 KHN. Não houve diferença estatisticamente
significativa na resistência ao cisalhamento para o fator tempo (sete ou 30 dias; F5,54=
0,105, p= 0,901), contudo, houve diferença estatisticamente significativa para o fator
solução (F5,54= 6,671; p= 0,003). O Teste Post Hoc de Tukey identificou que estas
diferenças ocorreram entre as soluções Saliva x Coca-Cola® (p= 0,003) e Coca-Cola® x
Suco de limão (p= 0,029). Ao se comparar se o tempo de tratamento seria significativo
para os resultados do cisalhamento em cada solução, o Teste T não revelou influência
do tempo para nenhuma solução utilizada. Conclui-se que o tempo de protocolo
utilizado não influencia na resistência adesiva do bráquete ao dente, porém em relação
às substâncias de imersão, a Coca-Cola® apresentou maiores valores de resistência ao
cisalhamento.
|
50 |
Estudo in vivo da margem da interface braquete/esmalte por meio de microscopia optica e laser de fluorescencia / In vivo marginal evaluation of the bracket/enamel interface using optical microscopy and fluorescent laserQueiroz, Vanessa Salvadego de 27 April 2007 (has links)
Orientadores: Darcy Flavio Nouer, Paulo Roberto Aranha Nouer / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-08T18:00:39Z (GMT). No. of bitstreams: 1
Queiroz_VanessaSalvadegode_M.pdf: 1882065 bytes, checksum: 8fbe21dcd63e35f093d5db84e1faff56 (MD5)
Previous issue date: 2007 / Resumo: Este trabalho teve como objetivo avaliar in vivo a superfície do esmalte de dentes humanos e a margem da interface braquete/esmalte por meio de microscopia óptica e laser de fluorescência. Foram analisados premolares com indicação de extração, de 35 pacientes, com idades entre 11 e 20 anos, em início de tratamento ortodôntico, divididos em grupo 1 (flúor-controle n=15), sendo 5 do gênero masculino e 10 do feminino, e grupo 2 (pré-flúor n=20), sendo 9 do gênero masculino e 11 do feminino. No total, avaliaram-se 137 dentes e 207 faces de colagem. Em cada dente observaram-se 9 pontos, sendo as 4 margens das interfaces braquete/esmalte (pontos próximos), 4 pontos à 2mm destas (pontos distantes) e 1 ponto de calibração. A avaliação foi realizada: no dia da colagem do braquete (F1), uma semana pós-colagem (F2) e quatro semanas pós-colagem (F3). Para o grupo 2, acrescentou-se uma avaliação 15 dias antes da colagem (F0). Os pacientes receberam dentifrício contendo 1.450 ppm de flúor (MFP), uma escova dentária e foram orientados à escovação 3x/dia, após as principais refeições, sendo que foram instruídos a diminuir o consumo de açúcar. Tais instruções e produtos foram oferecidos na F1 para o grupo 1 e na F0 para o grupo 2; além disso, o grupo 2 também recebeu um isolamento superficial ao redor da área de colagem. Para as avaliações, foram utilizados o laser de fluorescência - DIAGNOdent e o microscópio óptico - Sistema Galileu inclinado, acoplado a uma câmera digital Sentech STC-C83USB-AT. Para a colagem dos braquetes Microarch, utilizou-se 4 diferentes materiais: Transbond XT; Concise Ortodôntico; Fuji Ortho LC; e Monolok2. Os dados foram submetidos às análises estatísticas Mann-Whitney, Wilcoxon e Friedman (p > 0,05) e foram obtidos os seguintes resultados: as leituras com o DIAGNOdent foram significantemente maiores, ou seja, maior desmineralização, nos pontos próximos que nos distantes, em ambos os grupos; o grupo 1 apresentou leituras maiores que o grupo 2 em todas as fases do estudo; houve diminuição das leituras com o laser no decorrer das fases do estudo, para ambos os grupos; não houve diferença estatisticamente significante nas leituras para nenhum dos materiais; quanto aos gêneros, no grupo 1, o masculino apresentou leituras maiores que o feminino; já no grupo 2, o gênero feminino apresentou leituras maiores que o masculino; a face vestibular apresentou leituras maiores que a palatina em todas as fases, grupos e gêneros; foi encontrado menos excesso de material de colagem nas margens das interfaces do grupo 2 e isso parece indicar que o isolamento ao redor da área de colagem proporcionou maior proteção, porém, a presença de excesso não esteve correlacionada com o aumento de leitura do DIAGNOdent. Pôde-se concluir que o uso de dentifrício fluoretado e higienização bucal 3x/dia, com motivação semanal e controle da dieta colaboraram para a diminuição da desmineralização e/ou aumento da remineralização da superfície de esmalte, sendo que, de acordo com os resultados obtidos, esses procedimentos devem se iniciar antes da instalação do aparelho ortodôntico fixo / Abstract: The aim of this study was to evaluate in vivo the human tooth enamel surface and the bracket/enamel interface through optical microscopy and fluorescent laser. Premolars, indicated for extraction, from 35 patients (between 11 e 20 years old) beginning orthodontic treatment were evaluated. The patients were divided into 2 groups: G1 (control-fluor) (n=15) consisting of 5 males and 10 females; and G2 (pre-fluor) (n=20) consisting of 9 males and 11 females. A total of 137 teeth and 207 bond faces were evaluated. Nine points of each tooth were analyzed: 4 bracket/enamel interfaces (near points), 4 points 2mm far from these interfaces (far points) and 1 calibration point. The patients received a 1.450 ppm MFP fluoride toothpaste and a toothbrush and were instructed to brush 3x/day, after the principal meals and restrict the sugar consume. The evaluation was separated in the following Phases: at the day of bracket bonding (F1), a week after bonding (F2), and four weeks after bonding (F3). Group 2 was also evaluated 15 days before bonding and oral hygiene instructions (F0). Group 1 received the instructions at the F1 and group 2 received those at the F0. In addiction, in the group 2, the bonding area received a protection layer. It was used the DIAGNOdent and a visual inspection using optical microscopy, Galileu System (200mm) coupled to a Sentech Digital Camera model STC-C83USB-AT. The Microarch brackets were bonded with 4 different materials: Transbond XT; Orthodontic Concise; Fuji Ortho LC; and Monolok2. The data was statistically analyzed by Mann-Whitney, Wilcoxon and Friedman (p > 0,05) and DIAGNOdent showed readings significantly higher near the brackets than at far points, for both groups. However, group 1 showed higher readings at all phases tested. The laser readings decreased according to the phases, for both groups. The results showed no statistically difference between the materials used. Considering patient gender, in group 1, males showed higher readings. Females showed higher readings in group 2, though. Buccal aspect showed higher readings than palatine aspect at all phases and for both groups and genders evaluated. It was found less material excess for group 2, and this result indicates that the vaseline layer protected the interface, although the material excess was not related to DIAGNOdent readings. In conclusion, the use of fluoride toothpaste and oral hygiene with toothbrush 3x/day, added to weekly motivation and diet control can help reducing enamel demineralization and/or increasing remineralization. According to the present results, these procedures must be done before orthodontic bonding / Mestrado / Ortodontia / Mestre em Radiologia Odontológica
|
Page generated in 0.069 seconds