• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 11
  • 1
  • Tagged with
  • 12
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise Limite em Geomecânica utilizando Programação Cônica

JUSCAMAYTA, Victor Ernesto Alejo 17 February 2016 (has links)
Submitted by Isaac Francisco de Souza Dias (isaac.souzadias@ufpe.br) on 2016-07-07T18:35:27Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) dissertação.pdf: 6420161 bytes, checksum: b09629f500126d4eb53c955503dd8651 (MD5) / Made available in DSpace on 2016-07-07T18:35:27Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) dissertação.pdf: 6420161 bytes, checksum: b09629f500126d4eb53c955503dd8651 (MD5) Previous issue date: 2016-02-17 / CAPES / A análise limite visa a determinação das cargas que provocará o fenômeno do colapso plástico incipiente, que se caracteriza pelo desenvolvimento de deformações indefinidamente crescentes à carregamento constante. Este trabalho trata do cálculo da carga de colapso em problemas da mecânica dos sólidos. Do ponto de vista matemático a análise limite é essencialmente um problema de otimização, que compreende o conjunto da teoria matemática e de métodos de resolução relativos ao problema de minimizar (ou maximizar) um funcional cujas variáveis são restritas a um domínio definido por uma série de igualdades e desigualdades. Serão utilizados os princípios variacionais estático, cinemático e misto. A restrição do critério de plastificação induz a um problema de otimização não linear para a análise limite. Neste trabalho no entanto, será utilizada a programação cônica de segunda ordem (SOCP). Trata-se de uma formulação nova de programação, com restrições cônicas. Sua utilização é crescente nos problemas de otimização. Atualmente há alguns programas livres e comerciais em utilização na literatura. Podemos citar o SeDuMi, um dos primeiros em uso. Há também o MOSEK, um código comercial com disponibilidade gratuita para universidades e o SDPT3, código aberto e gratuito. Neste trabalho foi utilizado o SDPT3 que demonstrou maior capacidade de resolução com malhas grandes de milhares de elementos e apresentou uma deferência menor entre as soluções primal e dual. Neste trabalho se desenvolveu um programa de elementos finitos e análise limite com otimização cônica FELA (finite element limit analysis). / Limit analysis aim at determining threshold load that causes the phenomenon of incipient plastic collapse, which is characterized by the development of indefinitely growing strains at constant load. This work deals with the calculation of collapse load in solid mechanics problems. From a mathematical point of view limit analysis is essentially an optimization problem, which comprises the mathematical theory and resolution methods for minimization (or maximization) problem of a functional whose variables are restricted to a domain defined by a series of equalities and inequalities. Static, kinematic and mixed variational principles will be used. Yielding criterion restriction induces to a nonlinear optimization problem for limit analysis. In this work however, it will be used the second order conic programming (SOCP). It is a new programming formulation with conical restrictions. Its use is growing in optimization problems. Currently there are some free and commercial programs in use in the literature. We can mention SeDuMi, one of the first in use. There is also MOSEK, a commercial code with free availability to universities and SDPT3, open and free code. In this study we used SDPT3 that showed higher resolution capability with large meshes of thousands of elements and had a lower deference between the primal and dual solutions. In this work it was developed a finite element program
2

Uma proposta para o ensino de cônicas com o auxílio do software Maple

Lima, Edison Fernando da Silva 08 May 2015 (has links)
Submitted by Jean Medeiros (jeanletras@uepb.edu.br) on 2016-04-19T13:56:14Z No. of bitstreams: 1 PDF - Edison Fernando da Silva Lima.pdf: 9125981 bytes, checksum: 332497337ebe6b4a6871009d22dde972 (MD5) / Approved for entry into archive by Secta BC (secta.csu.bc@uepb.edu.br) on 2016-07-22T20:24:27Z (GMT) No. of bitstreams: 1 PDF - Edison Fernando da Silva Lima.pdf: 9125981 bytes, checksum: 332497337ebe6b4a6871009d22dde972 (MD5) / Made available in DSpace on 2016-07-22T20:24:34Z (GMT). No. of bitstreams: 1 PDF - Edison Fernando da Silva Lima.pdf: 9125981 bytes, checksum: 332497337ebe6b4a6871009d22dde972 (MD5) Previous issue date: 2015-05-08 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / In this course conclusion work we will of conic approach in the study of analytic geometry and treat procedures in order to recognize the nature of the general equation of a curve of the second degree two variables, performing the analysis of the coefficients of your equation by an algebraic process. Simplification of calculations involved as well as the graphics sketch, the mathematical application Maple 18 will be used. Our aim is to develop students’ ability to relate and better secure the maths contents, since such an approach is not worked in textbooks the high school level. / Neste trabalho de conclusão de curso faremos uma abordagem das cônicas no estudo da Geometria Analítica e trataremos de procedimentos com a finalidade de se reconhecer a natureza da equação geral de uma curva do segundo grau a duas variáveis, realizando a análise dos coeficientes de sua equação por um processo algébrico. Na simplificação dos cálculos envolvidos, bem como no esboço de gráficos, será usado o aplicativo matemático Maple 18. Nosso intuito é desenvolver a habilidade dos alunos em relacionar e melhor fixar os conteúdos matemáticos abordados, visto que, tal abordagem não é trabalhada nos livros didáticos a nível de ensino médio.
3

Análise fotoelástica comparativa entre pilares protéticos sólidos e de parafuso passante para implantes com conexão cônica instalados em diferentes profundidades ósseas / Comparative photoelastic analysis between standard and regular ankylos abutments in conical abutment connection implants installed in different bone depths

Provinciatti, Mauricio Martins 22 January 2016 (has links)
As tensões de baixa intensidade contribuem para a remodelação óssea nos implantes osseointegráveis, enquanto as tensões de alta intensidade causam a reabsorção óssea abaixo da interface implante-pilar. A sobrecarga oclusal afeta a fisiologia do tecido ósseo, rompendo com o equilíbrio entre a neoformação e a reabsorção. Como consequência da desarmonia, lacunas surgem em meio a superfície óssea, criando um ambiente favorável à proliferação de patógenos e ao acúmulo de fibras. Com a continuidade da sobrecarga e com a permanência dos microrganismos o suporte ósseo é comprometido, resultando na falha do implante. Em condições normais de carregamento, os implantes com conexão cônica possibilitam uma distribuição homogênea das tensões. O posicionamento da plataforma protética abaixo da crista óssea determina a transferência das tensões para áreas distantes ao osso cortical. O presente estudo utilizou a análise fotoelástica para avaliar a distribuição de tensão em modelos experimentais com implantes com conexão cônica instalados na posição equicristal, 1,5 mm infraósseo e 3,0 mm infraósseo. Foram propostas reabilitações com coroas protéticas unitárias em cerâmica, cimentadas em pilares protéticos sólidos e de parafuso passante com alturas de transmucoso de 1,5 mm, 3,0 mm e 4,5 mm. Os implantes foram posicionados na posição correspondente ao primeiro molar inferior direito. Segundo as situações adotadas, os conjuntos implante/pilar foram avaliados isoladamente, adjacentes a réplicas do segundo pré-molar inferior direito e do segundo molar inferior direito e apenas adjacentes a réplicas do segundo pré-molar inferior direito. A carga aplicada aos modelos fotoelásticos foi de 200 Ncm para todas as situações. Nos modelos com réplicas dentais foi realizado o carregamento oclusal distribuído, nos modelos com implantes isolados o carregamento foi pontual na fossa central e distal das coroas protéticas. Os resultados obtidos revelaram que a indicação de um pilar protético em detrimento a outro se configurou segundo a presença ou não de elemento dental posterior à coroa protética, assim como também por intermédio da profundidade da plataforma do implante na crista óssea remanescente. Em extremidades livres com implantes infraósseo a distribuição de tensão proporcionada pelo pilar de parafuso passante foi superior a do pilar sólido. Com a presença do segundo molar a distribuição da tensão foi mais eficiente com o pilar sólido, independentemente da profundidade da plataforma do implante. Nos modelos fotoelásticos com extremidade livre, o deslocamento da plataforma para uma posição infraóssea determinou menores tensões ao tecido ósseo. Havendo contatos proximais bilaterais a distribuição da tensão foi favorecida quando o implante ocupou a posição infraóssea a 3,0 mm, estando conectado ao pilar de parafuso passante. Entretanto, quando conectado ao pilar sólido o implante equicristal apresentou melhor distribuição de tensão que os implantes infraósseo. / Low-intensity stresses contribute to bone remodeling, while high intensity stresses cause bone resorption, below implant-abutment junction in dental implants. The occlusal overload affects the physiology of bone tissue, disrupting the balance between new formation and resorption. As a result of the disharmony, gaps arise in the crestal bone, creating a favorable environment for the proliferation of pathogens and fiber accumulation. With the continued overloading and the permanence of microorganisms, the bone support is impaired, resulting in implant failure. In normal loading conditions the tapered connection implants enables a homogeneous distribution of stresses. The subcrestal positioning of the prosthetic platform determines the transfer of stresses to distant areas from the cortical bone. This study used photoelastic analysis to evaluate the stress distribution in experimental models in conical abutment connection implants placed in equicristal position, 1.5 mm and 3.0 mm subcrestal positions. Rehabilitations were proposed for single prosthetic ceramic crowns cemented in standard and regular Ankylos prosthetic abutments with transmucosal height of 1.5 mm, 3.0 mm and 4.5 mm. Implants were placed in the position corresponding to the first lower right molar. According to the chosen situations, sets of implant/abutments were evaluated separately, adjacent to replicas of the second lower right premolar and second lower right molar and just adjacent to replicas of the second right premolar. The load applied to the photoelastic models was 200 Ncm in all cases. In models with dental replicas, distributed occlusal loading was performed; on models with isolated implant, loading was precise in the central and distal fossa of prosthetic crowns. The results showed that the indication of an abutment over another is depended on the presence or absence of a dental element posterior to the prosthetic crown, and of the implant platform depth of the remaining bone crest. In distal extension with subcrestal implants, stress distribution provided by Regular Ankylos prosthetic abutments was better than that provided by the Standard Ankylos abutment. With the presence of the second molar distribution of stress was more efficient with the Standard Ankylos abutment, regardless of the depth of the implant platform. In photoelastic models with distal extension, the platform displacement to a subcrestal position determined lower stress to the bone. Having bilateral proximal contacts, the stress distribution was favored when the implant was placed in a 3.0 mm subcrestal position with Regular Ankylos prosthetic abutments. However, when connected to the Standard Ankylos abutment, implant placed in equicristal position showed better stress distribution than subcrestal implants.
4

Análise fotoelástica comparativa entre pilares protéticos sólidos e de parafuso passante para implantes com conexão cônica instalados em diferentes profundidades ósseas / Comparative photoelastic analysis between standard and regular ankylos abutments in conical abutment connection implants installed in different bone depths

Mauricio Martins Provinciatti 22 January 2016 (has links)
As tensões de baixa intensidade contribuem para a remodelação óssea nos implantes osseointegráveis, enquanto as tensões de alta intensidade causam a reabsorção óssea abaixo da interface implante-pilar. A sobrecarga oclusal afeta a fisiologia do tecido ósseo, rompendo com o equilíbrio entre a neoformação e a reabsorção. Como consequência da desarmonia, lacunas surgem em meio a superfície óssea, criando um ambiente favorável à proliferação de patógenos e ao acúmulo de fibras. Com a continuidade da sobrecarga e com a permanência dos microrganismos o suporte ósseo é comprometido, resultando na falha do implante. Em condições normais de carregamento, os implantes com conexão cônica possibilitam uma distribuição homogênea das tensões. O posicionamento da plataforma protética abaixo da crista óssea determina a transferência das tensões para áreas distantes ao osso cortical. O presente estudo utilizou a análise fotoelástica para avaliar a distribuição de tensão em modelos experimentais com implantes com conexão cônica instalados na posição equicristal, 1,5 mm infraósseo e 3,0 mm infraósseo. Foram propostas reabilitações com coroas protéticas unitárias em cerâmica, cimentadas em pilares protéticos sólidos e de parafuso passante com alturas de transmucoso de 1,5 mm, 3,0 mm e 4,5 mm. Os implantes foram posicionados na posição correspondente ao primeiro molar inferior direito. Segundo as situações adotadas, os conjuntos implante/pilar foram avaliados isoladamente, adjacentes a réplicas do segundo pré-molar inferior direito e do segundo molar inferior direito e apenas adjacentes a réplicas do segundo pré-molar inferior direito. A carga aplicada aos modelos fotoelásticos foi de 200 Ncm para todas as situações. Nos modelos com réplicas dentais foi realizado o carregamento oclusal distribuído, nos modelos com implantes isolados o carregamento foi pontual na fossa central e distal das coroas protéticas. Os resultados obtidos revelaram que a indicação de um pilar protético em detrimento a outro se configurou segundo a presença ou não de elemento dental posterior à coroa protética, assim como também por intermédio da profundidade da plataforma do implante na crista óssea remanescente. Em extremidades livres com implantes infraósseo a distribuição de tensão proporcionada pelo pilar de parafuso passante foi superior a do pilar sólido. Com a presença do segundo molar a distribuição da tensão foi mais eficiente com o pilar sólido, independentemente da profundidade da plataforma do implante. Nos modelos fotoelásticos com extremidade livre, o deslocamento da plataforma para uma posição infraóssea determinou menores tensões ao tecido ósseo. Havendo contatos proximais bilaterais a distribuição da tensão foi favorecida quando o implante ocupou a posição infraóssea a 3,0 mm, estando conectado ao pilar de parafuso passante. Entretanto, quando conectado ao pilar sólido o implante equicristal apresentou melhor distribuição de tensão que os implantes infraósseo. / Low-intensity stresses contribute to bone remodeling, while high intensity stresses cause bone resorption, below implant-abutment junction in dental implants. The occlusal overload affects the physiology of bone tissue, disrupting the balance between new formation and resorption. As a result of the disharmony, gaps arise in the crestal bone, creating a favorable environment for the proliferation of pathogens and fiber accumulation. With the continued overloading and the permanence of microorganisms, the bone support is impaired, resulting in implant failure. In normal loading conditions the tapered connection implants enables a homogeneous distribution of stresses. The subcrestal positioning of the prosthetic platform determines the transfer of stresses to distant areas from the cortical bone. This study used photoelastic analysis to evaluate the stress distribution in experimental models in conical abutment connection implants placed in equicristal position, 1.5 mm and 3.0 mm subcrestal positions. Rehabilitations were proposed for single prosthetic ceramic crowns cemented in standard and regular Ankylos prosthetic abutments with transmucosal height of 1.5 mm, 3.0 mm and 4.5 mm. Implants were placed in the position corresponding to the first lower right molar. According to the chosen situations, sets of implant/abutments were evaluated separately, adjacent to replicas of the second lower right premolar and second lower right molar and just adjacent to replicas of the second right premolar. The load applied to the photoelastic models was 200 Ncm in all cases. In models with dental replicas, distributed occlusal loading was performed; on models with isolated implant, loading was precise in the central and distal fossa of prosthetic crowns. The results showed that the indication of an abutment over another is depended on the presence or absence of a dental element posterior to the prosthetic crown, and of the implant platform depth of the remaining bone crest. In distal extension with subcrestal implants, stress distribution provided by Regular Ankylos prosthetic abutments was better than that provided by the Standard Ankylos abutment. With the presence of the second molar distribution of stress was more efficient with the Standard Ankylos abutment, regardless of the depth of the implant platform. In photoelastic models with distal extension, the platform displacement to a subcrestal position determined lower stress to the bone. Having bilateral proximal contacts, the stress distribution was favored when the implant was placed in a 3.0 mm subcrestal position with Regular Ankylos prosthetic abutments. However, when connected to the Standard Ankylos abutment, implant placed in equicristal position showed better stress distribution than subcrestal implants.
5

Uma nova proposta de antena banda larga para recepção do sinal de tv digital do padrão ISDB-T

Santos, Edson Tafeli Carneiro dos 05 February 2016 (has links)
Submitted by Rosa Assis (rosa_assis@yahoo.com.br) on 2016-09-22T14:43:47Z No. of bitstreams: 2 EDSON TAFELI CARNEIRO DOS SANTOS .pdf: 9777193 bytes, checksum: 7899eea8e7cc4550fef2b2744ddb778d (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2016-09-22T14:43:47Z (GMT). No. of bitstreams: 2 EDSON TAFELI CARNEIRO DOS SANTOS .pdf: 9777193 bytes, checksum: 7899eea8e7cc4550fef2b2744ddb778d (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2016-02-05 / The digital television reception system has a number of possible technological changes in its architecture. One of the changes is the transition from the VHF broadcast band to UHF. This fact requires a change in design, size and electrical characteristics of the radio receiver antenna side. Among the desirable characteristics of an antenna operating in this frequency band are: omnidirectionality, gain, directivity and wideband required to cover the entire range, combined with low cost and easy construction. This work proposes a new antenna, formed by a planar monopole acting as irradiator element and supported by a conical structure attached to a cylindrical shaped element with sleeve format that promotes an increase and control of the bandwidth required to cover the entire UHF band, including GSM850 and GSM900 bands. The design of the proposed antenna was performed with a full wave electromagnetic field simulator. A prototype was built and simulated and experimental results showed that the proposed antenna could cover the range of 469.6 MHz to 1387.4 MHz, with a steady-state wave ratio of less than 2. The performance of the proposed antenna was compared with other monopole antennas in relation to the received power level. A digital TV receiver was used to verify system performance in a closed and urban environment. / O sistema de recepção da TV digital apresenta diversas mudanças tecnológicas na sua arquitetura. Uma das mudanças, é a alteração da faixa de transmissão do VHF para o UHF. Esse fato impõe uma alteração no desenho, tamanho e características radio elétricas da antena no lado do receptor. Dentre as características desejadas de uma antena que opere nessa faixa de frequências está a ominidirecionalidade, ganho, diretividade e largura de banda elevada para cobrir toda a faixa necessária, aliado a um baixo custo e facilidade de construção. Esta pesquisa apresenta uma nova proposta de antena, composta por um monopolo planar como elemento irradiador, e suportado por uma estrutura em formato de tronco de cone unida a um elemento cilíndrico em forma de luva para promover aumento e controle da largura de banda necessários para cobrir toda a faixa do UHF, inclusive as bandas GSM850, e GSM900. A antena proposta foi projetada com simulador de campo eletromagnético de onda completa. Um protótipo foi simulado e construído e os resultados experimentais demonstraram que a antena pode cobrir a faixa de 469,6 MHz a 1387,4 MHz, com uma taxa de onda estacionária inferior a 2. O desempenho da antena proposta foi comparada com outras monopolos em relação ao nível de potência recebido. Um receptor de TV digital foi utilizado para verificar o desempenho do sistema em um ambiente fechado e urbano.
6

Análise da distribuição das tensões nas estruturas de suporte de overdentures, rebordo residual e implantes, com sistema de conexão de coroas cônicas (Syncone-Dentsply). / Analysis of the tensions distribution in the structures of overdentures support, residual alveolar ridge and implants, with connection of conical crowns system (Syncone-Dentsply)

Guariglia, Ana Cristina Aurora Rosa Perasso 22 March 2007 (has links)
O sistema de osseointegração desenvolvido por Branemark revolucionou o campo das reabilitações protéticas, incentivando os profissionais a indicar e realizar próteses do tipo overdentures. Estes dispositivos representam uma ótima alternativa para solucionar os problemas dos pacientes desdentados, insatisfeitos por diversos fatores. Várias são as associações entre os implantes e os sistemas de conexões empregados em overdentures. A literatura e a prática clínica fazem observar que na dependência do sistema de conexão empregado, há uma diferença no comportamento biomecânico, realizado por este conjunto: prótese/implante/conexão. Desta forma, é importante analisar como as tensões se distribuem sobre as estruturas que suportam estas cargas, uma vez que não existe o ligamento periodontal ao redor dos implantes que promove o mecanismo fisiológico, natural nos dentes. Assim, o objetivo desta investigação foi de avaliar, com o auxílio do método fotoelástico, o comportamento da distribuição das tensões em sobredentaduras (overdentures), suportadas por quatro implantes Ankylos®/ Dentsply®, utilizando-se o sistema protético de conexão de coroas cônicas Syncone®/ Dentsply®, onde se comparou duas formas de distribuição dos implantes, na primeira (CPM1) os implantes foram posicionados nas regiões de incisivos centrais e pré-molares e o segundo (CPM2) os implantes estavam posicionados nas regiões de caninos e pré-molares. Os modelos receberam cargas de forma crescente de 0,0 a 9,0 kg e, as tensões resultantes nas estruturas de suporte, foram analisadas fotoelasticamente. De acordo com a metodologia empregada nesta pesquisa, somos levados a concluir que: 1) Quando se associa o sistema Syncone® com overdenture ou sobredentadura, apoiada e retida sobre quatro implantes, sendo 2 localizados na região de incisivos centrais e 2 situados, diametralmente opostos, na região de segundos pré-molares na mandíbula - CPM1 - o rebordo residual é quem recebe a maior quantidade de tensões em relação aos implantes; 2) Quando se associa o sistema Syncone® com overdenture ou sobredentadura, apoiada e retida sobre 4 implantes, dispostos 2 a 2, bilateralmente e diametralmente opostos, nas regiões de caninos e pré-molares, na mandíbula (CPM2), as maiores tensões são transmitidas ao rebordo residual, sendo que os implantes suportes resultam mais preservados; 3) Comparativamente, o CPM2, aparenta ter transmitido menores tensões aos implantes que o CPM1; 4) Os implantes são preservados quanto à ocorrência de uma sobrecarga, durante a máxima intercuspidação dos arcos dentários, quando se emprega o sistema Syncone® associado à overdenture ou sobredentadura. / The osseo-integrated system develop by Branemark has revolutionized the prosthetic rehabilitation field, encourage the professionals to indicate and perform prostheses like overdentures. These devices represent an optimal alternative to solve the full dentures patient?s problems, dissatisfied for diverse factors. There are several associations between implants and prosthetic connectors employees for overdentures. The literature and the clinic practice may observe that according of the connection system employed, there is a difference into the biomechanical behavior, realized for this set: prostheses/implant/connection. From this forms, it is important to analyze how the tensions are distributing on the structures subject that support these loads, since it doesn\'t exist the periodontal ligament around the implants, what promotes the physiological mechanism of the natural teeth. Such, the purpose from this investigation was appraising, with the aid of the photoelastic method, the distribution way from the tensions at the overdentures, supported by four implants Ankylos®/ Dentsply, by using the prosthetic system of connection of conic crowns ? Syncone®/ Dentsply, were applied loads from 0,0 to 9,0kg, in crescent forms and, the tensions resulting on the support structures, have been analyzed by the photoelasthic method. Where two forms of distribution of the implantations were compared, first (CPM1) the implants were located at the regions of the central incisors and pre-molar, and as (CPM2) the implants were located at the regions of canines and pre-molar. The models had received loads of increasing form, from 0,0 to 9,0 kg and, the resultant tensions in the support structures, had been analyzed by the photoelastic method. In agreement with the methodology used in this research, we are led to conclude that: 1) When the overdenture is associated with Syncone® system, supported and retained by 4 implants, being 2 located in the region of central incisors and 2, diametrical opposing ones, in the region of the second pre-molar (CPM1) the residual alveolar ridge is who receives the biggest amount of tensions in relation to the implants; 2) When the overdenture is associated with Syncone® system, supported and retained by 4 implants, bilaterally and diametrical opposing ones, in the regions of canine and pre molar (CPM2), the biggest tensions were transmitted to the residual alveolar ridge, being the implants supports resulted more preserved; 3) Comparatively, the CPM2, seems to have transmitted less tensions to the implants than the CPM1; 4) The implants were preserved as the occurrence of an overload, during the maximum intercuspidação of the dental arcs, when the overdenture associated with Syncone® system has been used.
7

Estudo de Espalhamento em Sistemas Aharonov-Bohm em Espaço Cônico

Salem, Vinícius 13 March 2017 (has links)
Made available in DSpace on 2017-07-21T19:25:55Z (GMT). No. of bitstreams: 1 Vinicius Salem.pdf: 2842532 bytes, checksum: 22444ff7cd1897f8dc66bfd6a1f84a65 (MD5) Previous issue date: 2017-03-13 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / In the present work, it is explained in a concise way the Aharonov-Bohm (AB) Efect in the magnetic case. Possible interpretations envolving the phenomena are discussed too, through a carefull review about the theme in literature, in purpose to sumarize the diferent interpretations concerning the possible physical reality of electromagnetic potentials in physics, in special the case of the vector potential, since this work focuses in the magnetic AB eect. Also, the construction and solution of Dirac equation is studied in details for the non-relativistic limit case of an electron possessing anomalous magnetic moment (i.e., g 6=2) in a conical space. For this purpose, the self-adjoint extensions method as developed by Bulla and Gesztesy is used in order to obtain expressions for bound states energies and scattering. The self-adjoint extension parameter obtained in the study of bound states and scattering showed very plausible physical results, consonant with the literature in general, as exposed in detail in chapter four. Finally, it is discussed the role of anomaly of the electron magnetic moment in providing bound states energies, a theme rarely discussed in literature since now. / No presente trabalho, procura-se explicar de forma concisa a fenomenologia do Efeito Aharonov-Bohm (AB) magnético, bem como o sistema aplicado a partículas de spin 1/2. Também são discutidas possíveis interpretações para o fenômeno através de uma cuidadosa revisão sobre o tema na literatura, buscando sumarizar as distintas opiniões sobre a possível realidade física dos potenciais eletromagnéticos, em especial do potencial vetor, uma vez que o foco neste trabalho concentra-se no Efeito AB magnético. Posteriormente,é estudada em detalhes a construção e solução da Equação de Dirac para o caso limite não-relativístico do elétron com anomalia do momento magnético (i.e., g 6= 2) em uma topologia cônica. Para isto é utilizado o método de extensão auto-adjunta de operadores na versão desenvolvida por Bulla e Gesztesy, afím de obter expressões para as energias de estados ligados e espalhamento. O parâmetro de extensão obtido no estudo de estados ligados e espalhamento apresentou resultados físicos consistentes com a literatura em geral. Por fím, o papel da anomalia no momento magnético do elétron em proporcionar estados ligados no sistema é discutido detalhadamente, algo até então pouco abordado na literatura.
8

Despacho ótimo de geração e controle de potência reativa no sistema elétrico de potência /

Yamaguti, Lucas do Carmo. January 2019 (has links)
Orientador: Jose Roberto Sanches Mantovani / Resumo: Neste trabalho são propostos modelos matemáticos determinístico e estocástico de programação cônica de segunda ordem em coordenadas retangulares para o problema de fluxo de potência ótimo de geração e controle de potência reativa no sistemas elétricos de potência, considerando as minimização dos custos de geração de energia, perdas ativas da rede e emissão de poluentes no meio ambiente. Os modelos contemplam as principais características físicas e econômicas do problema estudado, assim como os limites operacionais do sistema elétrico. Os modelos são programados em linguagem AMPL e suas soluções são obtidas através do solver comercial CPLEX. Os sistemas testes IEEE30, IEEE118 e ACTIVSg200 são utilizados nas simulações computacionais dos modelos propostos. Os resultados obtidos pelo modelo determinístico desenvolvido são validados através de comparações com os resultados fornecidos pelo software MATPOWER , onde ambos consideram apenas a existência de gerações termoelétricas. No modelo estocástico utiliza-se a técnica de geração de cenários e considera-se um período de um ano (8760 horas), e geradores que utilizam fontes de geração renováveis e não renováveis. / Abstract: In this work we propose deterministic and stochastic mathematical models of second order conical programming in rectangular coordinates for the optimal power flow problem of reactive power generation and control in electric power systems, considering the minimization of energy generation costs, losses networks and emission of pollutants into the environment. The models contemplate the main physical and economic characteristics of the studied problem, as well as the operational limits of the electric system. The models are programmed in AMPL language and their solutions are obtained through the commercial solver CPLEX. The IEEE30, IEEE118 and ACTIVSg200 test systems are used in the computer simulations of the proposed models. The results obtained by the deterministic model developed are validated through comparisons with the results provided by the software MATPOWERR , where both consider only the existence of thermoelectric generations. The stochastic model uses the scenario generation technique and considers a period of one year (8760 hours), and generators using renewable and non-renewable generation sources. / Mestre
9

Cúbicas Reversas e Redes de Quádricas

Freire, Ageu Barbosa 09 March 2016 (has links)
Submitted by ANA KARLA PEREIRA RODRIGUES (anakarla_@hotmail.com) on 2017-08-17T12:22:57Z No. of bitstreams: 1 arquivototal.pdf: 697305 bytes, checksum: 0b28f8f8c4f8b4509047eb441817be7c (MD5) / Made available in DSpace on 2017-08-17T12:22:57Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 697305 bytes, checksum: 0b28f8f8c4f8b4509047eb441817be7c (MD5) Previous issue date: 2016-03-09 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / In this work, we present an explicit geometric characterization for the space of quadratcs form vanishing precisely on a twisted cubic. We show that the set of degenerate quadrics lying on a net of quadrics containing a twisted cubic is described by a curve whose equation is given by the square of an irreducible conic. Conversely, if is a net of quadrics whosw intersection with the set of degenerate quadrics is a curve given by the square of an irreducible conic, we furnish conditions under which the cammon zero locus of turns out to be a twisted cubic. It is enough to require that does not contain a pair of planes. / Neste trabalho, apresentamos uma caracteriza c~ao geom etrica expl cita para o espa co das formas quadr aticas que se anulam precisamente sobre uma c ubica reversa. Mostramos que o conjunto das qu adricas degeneradas pertencentes a uma rede de qu adricas que cont em a c ubica reversa e descrita por uma curva cuja equa c~ao e dada pelo quadrado de uma c^onica irredut vel. Rec procamente, se e uma rede de qu adricas cuja interse c~ao com o conjunto das qu adricas n~ao degeneradas e uma curva dada pelo quadrado de uma c^onica irredut vel, fornecemos condi c~oes sob as quais o lugar dos zeros comuns de seja uma c ubica reversa. E su ciente que n~ao contenha um par de plano.
10

Um algoritmo branch-and-bound para o problema do caixeiro viajante suficientemente próximo

Coutinho, Walton Pereira 13 February 2014 (has links)
Made available in DSpace on 2015-05-08T14:53:38Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 7900350 bytes, checksum: fbca2db827307d8c3ed2a1c15067d0da (MD5) Previous issue date: 2014-02-13 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / This research deals with the Close-Enough Traveling Salesman Problem, a variant of the Traveling Salesman Problem wich has several applicatios in logistics. In the Close-Enough Traveling Salesman Problem, rather than visiting the vertex (customer) itself, the salesman must visit a specific region containing such vertex. To solve this problem, we propose a simple yet effective exact algorithm, based on Branch-and-Bound and Second Order Cone Programming. The proposed algorithm was tested in 824 instances suggested in the literature. Optimal solutions are obtained for open problems with up to a thousand vertices. We consider both instances in the two- and three-dimensional space. / Esta pesquisa trata do Problema do Caixeiro Viajante Suficientemente Próximo, uma variante do Problema do Caixeiro Viajante que possui diversas aplicações em logística. No Problema do Caixeiro Viajante Suficientemente Próximo, ao invés de visitar o próprio vértice (cliente), o caixeiro deve visitar uma região especifica contendo este vértice. Para resolver este problema, é proposto um algoritmo exato, simples e efetivo, baseado em branch-and-bound e Programação Cônica de Segunda Ordem. O algoritmo proposto foi testado em 824 instâncias sugeridas na literatura. Soluções ótimas foram obtidas para instâncias com até mil vértices. Foram consideradas instâncias nos espaços bi e tridimensional.

Page generated in 0.0685 seconds