• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 1
  • Tagged with
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Lastkapacitet hos murar byggdamed C3Cblocksystem® -Explosionslaster / Load capacity for wall built with C3Cblocksystem®- Explosion loads

Nimb, Linus, Jonsson, Stina January 2022 (has links)
Under den senaste tiden har det upplevts en större oro i omvärlden och fred är inte längreen självklarhet i Europa. Människor är oroliga för den eskalerande situationen i Europaoch det har skapat ett osäkert säkerhetspolitiskt läge i världen. Befintlig konstruktion,fasta installationer och människor kan i framtiden hamna i risk för allvarliga skador frånexplosioner. Detta är ett samhällsproblem som det bör finnas en lösning till. C3CEngineering AB är ett skandinaviskt företag som tillverkar prefabricerade betongblock avtill största del återvunnen betong. Betongblocken är utformade enligt lego-principen ochär lätta att etablera och stapla på varandra. Befintliga muruppställningar och blocktillämpas vid flera olika användningsområden, exempelvis återvinningscenter ochinfrastruktur. Betongblocken kan även ha betydande användning som skydd vidkrissituationer.Syftet med arbetet var att utforma olika muruppställningar med betongelement från C3CEngineering AB för skydd mot explosioner. Muruppställningarna skall fungera som enskyddsbarriär vid kris och skydda bakomliggande objekt och människor bakom muren.Betongblock C3Cblock® 1688 har använts för de olika muruppställningarna eftersom detfinns ett stort lagersaldo av blocken i Sverige. Blockdimensionen är (1600 x 800 x 800millimeter) och blocken har beräknats från minsta tillverkningshållfasthet C20/25.En explosionslast är en dynamisk belastning på en konstruktion. En statiskt ekvivalentlast har använts vid beräkningarna för detta arbete. Blocken och muruppställningarna harundersökts utifrån vilka dimensionerande laster de klarar av samt vid olikabelastningsfall. Vid dimensionering har splitterverkan, hållfasthet, skjuvning,dymlingsverkan, glidning, stjälpning, markbärighet och inverkan av utböjningkontrollerats. Splitterverkan har kontrollerats utifrån MSB:s dokument för skyddsrum ochbetonghållfasthet har kontrollerats enligt Eurocode 2. Intervjuer med en teknisk specialistfrån MSB har utförts för att få en korrekt beskrivning av explosionslasternas beteende.Målet är att blocken skall kunna användas i både fredstid och vid en eventuellkrissituation. Blocken kan användas i offentliga miljöer som bullerskydd ellerläktarplatser och kan snabbt etableras som skyddsmurar vid behov.Resultatet visar att murar utformade med längre hävarmar klarar generellt av störredimensionerande laster vid stjälpning. Vid användningen av kontreforer kan murar medfärre betongblock motstå samma dimensionerande laster jämfört med bredare och tyngremurar utan kontreforer. Densiteten hos betongelementen är betydelsefull i fleradimensionerade lastfall.Arbetets avgränsningar leder till att de angivna statiskt ekvivalenta lasterna från resultatetkan inte kopplas till exakta dynamiska laster från en specifik explosion. Vidare forskningrelaterad till hur dynamiska laster på muruppställningarna beräknas om till statisktekvivalenta laster är en förutsättning för att besvara detta.Endast en typ av betongblock har använts för att modellera murarna och användningen avandra blocktyper kan resultera i andra murar med nya dimensioner och dimensionerandelaster. / In order to account for the rising risk of injury and damage to structures and people fromexplosions, the use of mobile and stable concrete protection walls is more relevant thanever. The Scandinavian company C3C Engineering AB designs and produces concreteelements which can interlock using the lego principle. The load capacity before criticalfailure of protective walls using C3Cblock® 1688 has been investigated in this study.Several failure modes such as shrapnel damage, sliding and foundation deformation wasstudied, to name a few. For each type of protective wall and failure stats a maximum loadcapacity was calculated.The study intended to answer which failure mode occurs first for each type of protectivewall. The deciding factors that determine a wall's maximum load capacity againstexplosions were also studied and analysed.The results are based on calculations using Mathcad Prime 7.0.0, and interviews withemployees at C3C Engineering AB and consultants for Myndigheten för samhällsskyddoch beredskap (MSB). For control of concrete, formulas and values from Eurocode 2were used.The results indicate that the protective wall's leverage length is a decisive factor forseveral failure modes, followed by the total weight of the construction. Increasing thedensity for the concrete elements result in heavier walls and thus greatly benefits theconstruction as a whole.
2

Pros and Cons of Using Large Concrete Blocks in an Office Building Structure : Comfort, Stability, Sustainability

Baban, Shwan, Abolfazl, Asliyalfani January 2023 (has links)
In 2019, the cement industry used 280 million tons of oil equivalent, contributing to 7% of totalindustrial energy consumption. This resulted in 2.4 billion tons of CO2 emissions, constituting26% of the industrial sector’s CO2 output and 7% of global energy-related emissions. On theother hand, It is affordable, safe, and readily available, thanks to its construction error resistance. C3C is a company that takes advantage of waste concrete that has been produced and useit to mold concrete blocks that has different functions. This is a big environmental benefit. Themain function of these blocks has been to function as temporary or permanent partitions walls orsafety walls for accidental loads. The aim of this study is to investigate the feasibility and performance of a temporary office structure that is built majorly out of these C3C lego blocks froma comfort, stability and sustainability point of view. This data aids construction professionalsseeking cost-effective alternatives to traditional methods. Retrofitting and cascading offer economic and environmental benefits. Our goal is to discover innovative, sustainable constructionapproaches for future generations. The results show the importance of insulation positioning forthe comfort point of view. To ensure stability and analyse if the separation of the blocks occur,four RFEM models are made with focus on the tensile stresses and uplifting deflection of thewalls. In conclusion, this study provides ideas on how to design a temporary structure usingC3C lego blocks.Keywords: Concrete blocks, C3C blocks, FE models, life cycle analysis, mechanical connections, CO2 emissions.
3

Verifying the analysis of complement component C3 and C4 on Siemens Atellica NEPH 630

Engström, Fanny January 2023 (has links)
The complement components C3 and C4 are part of the complement system. The complement system has many tasks to perform in the body and consists of several proteins that all have unique tasks. C3 and C4 are examined, for example, if a deficiency is suspected, in the presence of autoimmune diseases or in the case of recurring bacterial infections. When verifying the analysis and after analyzing of external controls, it has been shown that the reference range is falsely high, especially for C3. The study therefore aimed to verify the analysis of C3 and C4 on Atellica NEPH 630 and establish a correct reference range for respective analysis. The method was verified by evaluating the precision of the method and by comparing the concentration of C3 and C4 measured on Cobas 6000 module C500 with the concentration measured on Atellica NEP 630. In addition, the reference intervals provided by Siemens were evaluated using samples from blood donors and from other healthy individuals. The verification began by performing quality controls on three different levels before analysis of samples. The coefficient of variation was less than 5 % for all control levels for both complement analysis. Reference values ​​for C3 were not in alliance with the reference values ​​provided by Siemens. A new proposed range for C3 is 0.48- 1.37 g/L, while the recommended range can be used for C4.
4

Lastkapacitet hos murar byggda med C3C blocksystem -översvämningslaster / Load capacity for walls built with C3C block system –flooding loads

Blomberg, Johan, Sörgårn, Alfred January 2021 (has links)
Floods are the natural disaster that causes the most deaths and economic damage in the world. Sweden has been relatively spared from casualties in connection with floods, but the material damage is significant. In the future, larger and more frequent floods are expected. It is therefore interesting to study new protection barriers with higher capacity. C3C Engineering AB is a Växjö-based company that manufactures concrete blocks according to the lego principle out of waste concrete. In 2021, C3C has 99 production sites spread around Sweden. In the study, four models of stacking C3Cblock® were analyzed.The aim of the study was to produce calculation materials that can be used for stacking and placing C3Cblock® for flood protections. To calculate the capacity of the models, three horizontal loads were assumed to act on the stacking: static water pressure, hydrodynamic water pressure and floating debris load. In the study, four interviews with experts in the flood area were conducted. The interviews provided an insight into how experts at the relevant authorities view Sweden's preparedness, management, planning against floods and which criteria for protection barriers are considered important.The results from the study show that the C3Cblock® largely manage the water velocities and water heights that the authority for protection and preparedness maps for. The work also shows that the impact of floating debris has a relatively small effect compared to the hydrodynamic and hydrostatic water load. As the calculation set-up has been in ideal conditions, it is important when using the C3Cblock® for flood prevention purposes to have knowledge of terrain conditions such as base material and ground slope. / Översvämningar är den naturkatastrof som orsakar flest antal dödsoffer och ekonomisk skada i världen. Sverige har varit relativt förskonat från dödsoffer i samband med översvämningar, men de materiella skadorna är betydande. I framtiden förväntas större och mer frekventa översvämningar. Det är därför intressant att studera nya skyddsbarriärer med högre kapacitet. C3C Engineering AB är ett Växjöbaserat företag som tillverkar betongblock enligt legoprincipenutav överbliven spillbetong. År 2021 har C3C 99 stycken produktionsplatser utspridda runt om i Sverige. I arbetet kontrollerades fyra modeller för stapling av C3Cblock®. Målet med arbetet var att ta fram beräkningsmaterial som kan användas vid stapling och placering av C3Cblock® i förebyggande syfte mot översvämningar. För att beräkna modellernas kapacitet antogs tre horisontella laster verka på staplingen: statiskt vattentryck, hydrodynamiskt vattentryck och drivgodslast. I arbetet har fyra stycken intervjuer med sakkunniga inom översvämningsområdetgenomförts. Intervjuerna gav en inblick i hur sakkunniga på berörda myndigheter ser på Sveriges beredskap, hantering, planering mot översvämningar och vilka kriterier för skyddsbarriärer som anses viktiga. Resultatet av arbetet visar att C3Cblock® till stor del klarar de vattenhastigheter och vattenhöjder som myndigheten för skydd och beredskap karterar för. Arbetet visar också att inverkan av drivgods har en relativt liten effekt jämfört med dethydrodynamiska- och hydrostatiska vattenlasten. Då beräkningsuppställningen varit i ideala förhållanden är det viktigt att vid användning av C3Cblock® i förebyggande syfte mot översvämningar ha kännedom kring terrängförhållanden som underlagsmaterial och marklutning.

Page generated in 0.035 seconds