• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 1
  • Tagged with
  • 4
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Stjälpning av en byggnad i KL-trä : En utvärdering av stelkroppsmetoden / Overturning of a CLT-building

Loo, Andreas January 2023 (has links)
21% av de växthusgaser som släpps ut i Sverige kommer från byggsektorn. Motsvarande siffra för avfall är 40% (Boverket, 2023). Ett fokus måste därför ligga på att använda hållbara alternativ. KL-trä är förnyelsebart samt minskar genom sin höga prefabriceringsgrad avfall på arbetsplatsen (Ramboll, u.å). Trä har många fördelar, men det finns fortfarande en skepsis i byggbranschen när det kommer till större byggnader. Därför är det viktigt att studera och bli bättre på att hantera de svagheter som byggmaterialet har så att tröskeln för att använda det sänks och vi i byggbranschen kan jobba mot ett mer hållbart byggande. Denna studie fokuserar på problematiken stjälpning. En lätt stomme påverkas mer av horisontalkrafter än vad en tyngre gör. Kontroll av statisk jämvikt görs antingen för hand eller med datorhjälp. Finita Elementmetoden, FEM, är en kraftfull metod för att förutsäga hur byggnaden kommer bete sig. Ett problem med FEM-modeller är att de snabbt blir komplexa och svårtolkade. Stelkroppsmetoden är ett sätt att kontrollera statisk jämvikt genom en handberäkning. Byggnaden ses som en sammanhängande stel kropp som roterar kring läsidans nedre kant. Metoden är väldigt förenklad. I verkligheten kan man förvänta sig att byggnaden roterar kring en linje längre in och att det finns en eftergivlighet i väggarna som håller emot. Flytt av denna linje i markplan benämns i rapporten som momentpunkt. Hur mycket av mothållande vägg i lovart som beräknas stabilisera benämns som lastbredd. Syftet med studien är att skapa en bättre förståelse för FEM-modellen samt hur stelkroppsmetoden kan varieras för att skapa en mer verklighetstrogen bild. Detta för att i framtida byggnationer göra det enklare för konstruktören att välja KL-trä som byggmaterial. För att uppnå detta varieras momentpunktens placering och lastbredd av mothållande långsida i en handberäkning med stelkroppsmetoden som grund. Detta resultat jämförs mot en FEM-modell för att sedan se vid vilket värde på momentpunkt och lastbredd som beräkningarna korrelerar. Studien är både explanativ och explorativ och utförs som en fallstudie av jämförande karaktär. Referensobjektet är en sex våningar hög kontorsbyggnad under uppförande i Östersund. Stommen består av ytterväggar i KL-trä samt ett pelar-balksystem av limträ i byggnadens mitt. Resultatet från handberäkningen presenteras i en tabell där det är intressant att undersöka vid vilka kritiska punkter som statisk jämvikt ej infaller. För en momentpunkt som ej är indragen krävs det för denna byggnad en lastbredd på 5 av 29 meter. Flyttas momentpunkten in 4 m så krävs en lastbredd på 13 m. Enligt en icke modifierad stelkroppsmetod erhålls ett mothållande moment på 30 MNm vilket kan jämföras med det stjälpande momentet på 13 MNm. Det resulterande momentet uppgår då till 17 MNm. FEM-modellen korrelerar med handberäkningen med det resulterande momentet på 6,6 MNm då momentpunkten väljs till 4 m. Motsvarande lastbredd blir i handberäkningen 24 m. Momentpunkten 3 m ger en korrelation vid 10,1 MNm. Det ger en motsvarande lastbredd på 27 m. Vid en momentpunkt under 2 m ger FEM konsekvent högre resulterande moment. Någon rotationspunkt kunde ej finnas för FEM-modellen, med följden att den lastbredd och momentpunkt som FEM-modellen motsvarar i en handberäkning förblir obestämd. / 21% of the greenhouse gases emitted in Sweden originate from the building sector. The corresponding figure for waste is 40% (Boverket, 2023). Therefore, the focus must be on using sustainable alternatives. Cross Laminated Timber (CLT) is renewable, and through its high degree of prefabrication, reduces waste at the construction site (Ramboll, u.å). Wood has many advantages, but there is still skepticism in the building sector when it comes to larger buildings. Therefore, it is important to study the building materials weaknesses so that the threshold for using it is lowered. This study focuses on the challenge of overturning. A lightweight structure is more affected by horizontal forces than a heavier one. Checking of static equilibrium is done either by hand or with computer assistance. The Finite Element Method, FEM, is a powerful method used by computers for predicting how a building will behave. A problem with FEM models is that they quickly become complex and difficult to interpret. The rigid body method is a way of checking static equilibrium through calculations done by hand. The building is seen as a coherent rigid body that rotates around the lower edge of the leeward side. This method is very simplified. In reality, one would expect the building to rotate around a line further in, and the stabilizing walls not to be completely rigid. The placement of this line in relation to the origin line is referred to as the rotation line. Load width is defined as the width of the stabilizing wall in the windward direction that is included in the calculation. The study aims to create a better understanding of the FEM model and how the rigid body method can be varied to generate a more realistic model. This is to facilitate CLT as a building material in future constructions. To achieve this, the position of the rotation line and the load width are varied in a calculation done by hand using the rigid body method. This result is compared against a FEM model to analyze where the rotation line and load width correlate in the different models. The study is both explanatory and exploratory and is carried out as a case study of a comparative nature. The reference object is a six-story office building in Östersund. The structure consists of outer walls in CLT and a post and beam system of glulam in the center of the building. The result from the calculation done by hand is shown in a table. Critical values occur where static equilibrium no longer can be verified. For the origin line, a loading width of 5 out of 29 meters are required for this building. If the rotation line is placed 4 m inward, a load width of 13 m is required. According to an unmodified rigid body method, a resisting moment of 30 MNm is obtained, which can be compared with the overturning moment of 13 MNm. The resulting moment totals 17 MNm. The FEM model correlates with the hand calculation with the resulting moment of 6.6 MNm when the rotation line is placed 4 m inward from the origin line. The corresponding load width is 24 m in the calculation done by hand. The rotation line at 3 m gives a correlation at 10.1 MNm. This gives a corresponding load width of 27 m. For rotation lines below 2 m, FEM consistently gives higher resulting moments. The rotation line specific to the FEM model could not be found, with the consequence that the load width and rotation line that the FEM model corresponds to in a calculation done by hand remains undetermined.
2

Load capacity of grouted rock bolts in concrete dams

Berzell, Carl January 2014 (has links)
The purpose of this thesis is to evaluate the contribution of grouted rock bolts on the stability of concrete dams. The load capacity of the grouted rock bolts are assessed considering eventual deteriorating processes. An additional objective was to compare the resulting load capacity with the prevailing regulations in RIDAS (the power companies’ guidelines on dam safety) and possibly suggest new guideline values. The literature study consists of two parts; concrete dams and grouted rock bolts. In the first part concrete dams are discussed and especially the inherent forces and aspects when controlling their stability. The second part treats grouted rock bolts and the theoretical focus is on their function and possible failure modes as well as on the degrading processes (primarily corrosion) that are affecting the rock bolts.  Subsequently, the theory was applied on the Swedish concrete buttress dam Storfinnforsen, which is the largest concrete dam in Sweden. The dam was selected for this study mainly because its shape is archetypical for buttress dams. In addition, a digitalized model of the dam was obtainable from previous research projects.  A numerical analysis with the finite element analysis software ABAQUS was performed in order to evaluate the stability of the dam and to support the analytical analysis. The load capacity of the grouted rock bolts was analytically evaluated with consideration to eventual degradation. Assuming a corrosion rate of 60 μm/year, the grouted rock bolts in Storfinnforsen could after 100 years be trusted with a load capacity of approximately 180 MPa. That load capacity is due to shear failure, which constitutes the most plausible failure mode for rock bolts in buttress dams. The value 180 MPa is to be seen in contrast to the current limitation of 140 MPa that is defined in RIDAS (2011). The conclusion of this thesis is accordingly, that the maximum allowed load capacity that can be assigned the grouted rock bolts in the stability calculations of concrete dams can be increased from todays 140 MPa. This conclusion is substantiated by the analytical analyses with the numerical calculations as support.
3

Lastkapacitet hos murar byggdamed C3Cblocksystem® -Explosionslaster / Load capacity for wall built with C3Cblocksystem®- Explosion loads

Nimb, Linus, Jonsson, Stina January 2022 (has links)
Under den senaste tiden har det upplevts en större oro i omvärlden och fred är inte längreen självklarhet i Europa. Människor är oroliga för den eskalerande situationen i Europaoch det har skapat ett osäkert säkerhetspolitiskt läge i världen. Befintlig konstruktion,fasta installationer och människor kan i framtiden hamna i risk för allvarliga skador frånexplosioner. Detta är ett samhällsproblem som det bör finnas en lösning till. C3CEngineering AB är ett skandinaviskt företag som tillverkar prefabricerade betongblock avtill största del återvunnen betong. Betongblocken är utformade enligt lego-principen ochär lätta att etablera och stapla på varandra. Befintliga muruppställningar och blocktillämpas vid flera olika användningsområden, exempelvis återvinningscenter ochinfrastruktur. Betongblocken kan även ha betydande användning som skydd vidkrissituationer.Syftet med arbetet var att utforma olika muruppställningar med betongelement från C3CEngineering AB för skydd mot explosioner. Muruppställningarna skall fungera som enskyddsbarriär vid kris och skydda bakomliggande objekt och människor bakom muren.Betongblock C3Cblock® 1688 har använts för de olika muruppställningarna eftersom detfinns ett stort lagersaldo av blocken i Sverige. Blockdimensionen är (1600 x 800 x 800millimeter) och blocken har beräknats från minsta tillverkningshållfasthet C20/25.En explosionslast är en dynamisk belastning på en konstruktion. En statiskt ekvivalentlast har använts vid beräkningarna för detta arbete. Blocken och muruppställningarna harundersökts utifrån vilka dimensionerande laster de klarar av samt vid olikabelastningsfall. Vid dimensionering har splitterverkan, hållfasthet, skjuvning,dymlingsverkan, glidning, stjälpning, markbärighet och inverkan av utböjningkontrollerats. Splitterverkan har kontrollerats utifrån MSB:s dokument för skyddsrum ochbetonghållfasthet har kontrollerats enligt Eurocode 2. Intervjuer med en teknisk specialistfrån MSB har utförts för att få en korrekt beskrivning av explosionslasternas beteende.Målet är att blocken skall kunna användas i både fredstid och vid en eventuellkrissituation. Blocken kan användas i offentliga miljöer som bullerskydd ellerläktarplatser och kan snabbt etableras som skyddsmurar vid behov.Resultatet visar att murar utformade med längre hävarmar klarar generellt av störredimensionerande laster vid stjälpning. Vid användningen av kontreforer kan murar medfärre betongblock motstå samma dimensionerande laster jämfört med bredare och tyngremurar utan kontreforer. Densiteten hos betongelementen är betydelsefull i fleradimensionerade lastfall.Arbetets avgränsningar leder till att de angivna statiskt ekvivalenta lasterna från resultatetkan inte kopplas till exakta dynamiska laster från en specifik explosion. Vidare forskningrelaterad till hur dynamiska laster på muruppställningarna beräknas om till statisktekvivalenta laster är en förutsättning för att besvara detta.Endast en typ av betongblock har använts för att modellera murarna och användningen avandra blocktyper kan resultera i andra murar med nya dimensioner och dimensionerandelaster. / In order to account for the rising risk of injury and damage to structures and people fromexplosions, the use of mobile and stable concrete protection walls is more relevant thanever. The Scandinavian company C3C Engineering AB designs and produces concreteelements which can interlock using the lego principle. The load capacity before criticalfailure of protective walls using C3Cblock® 1688 has been investigated in this study.Several failure modes such as shrapnel damage, sliding and foundation deformation wasstudied, to name a few. For each type of protective wall and failure stats a maximum loadcapacity was calculated.The study intended to answer which failure mode occurs first for each type of protectivewall. The deciding factors that determine a wall's maximum load capacity againstexplosions were also studied and analysed.The results are based on calculations using Mathcad Prime 7.0.0, and interviews withemployees at C3C Engineering AB and consultants for Myndigheten för samhällsskyddoch beredskap (MSB). For control of concrete, formulas and values from Eurocode 2were used.The results indicate that the protective wall's leverage length is a decisive factor forseveral failure modes, followed by the total weight of the construction. Increasing thedensity for the concrete elements result in heavier walls and thus greatly benefits theconstruction as a whole.
4

Lastkapacitet hos murar byggda med C3C blocksystem -översvämningslaster / Load capacity for walls built with C3C block system –flooding loads

Blomberg, Johan, Sörgårn, Alfred January 2021 (has links)
Floods are the natural disaster that causes the most deaths and economic damage in the world. Sweden has been relatively spared from casualties in connection with floods, but the material damage is significant. In the future, larger and more frequent floods are expected. It is therefore interesting to study new protection barriers with higher capacity. C3C Engineering AB is a Växjö-based company that manufactures concrete blocks according to the lego principle out of waste concrete. In 2021, C3C has 99 production sites spread around Sweden. In the study, four models of stacking C3Cblock® were analyzed.The aim of the study was to produce calculation materials that can be used for stacking and placing C3Cblock® for flood protections. To calculate the capacity of the models, three horizontal loads were assumed to act on the stacking: static water pressure, hydrodynamic water pressure and floating debris load. In the study, four interviews with experts in the flood area were conducted. The interviews provided an insight into how experts at the relevant authorities view Sweden's preparedness, management, planning against floods and which criteria for protection barriers are considered important.The results from the study show that the C3Cblock® largely manage the water velocities and water heights that the authority for protection and preparedness maps for. The work also shows that the impact of floating debris has a relatively small effect compared to the hydrodynamic and hydrostatic water load. As the calculation set-up has been in ideal conditions, it is important when using the C3Cblock® for flood prevention purposes to have knowledge of terrain conditions such as base material and ground slope. / Översvämningar är den naturkatastrof som orsakar flest antal dödsoffer och ekonomisk skada i världen. Sverige har varit relativt förskonat från dödsoffer i samband med översvämningar, men de materiella skadorna är betydande. I framtiden förväntas större och mer frekventa översvämningar. Det är därför intressant att studera nya skyddsbarriärer med högre kapacitet. C3C Engineering AB är ett Växjöbaserat företag som tillverkar betongblock enligt legoprincipenutav överbliven spillbetong. År 2021 har C3C 99 stycken produktionsplatser utspridda runt om i Sverige. I arbetet kontrollerades fyra modeller för stapling av C3Cblock®. Målet med arbetet var att ta fram beräkningsmaterial som kan användas vid stapling och placering av C3Cblock® i förebyggande syfte mot översvämningar. För att beräkna modellernas kapacitet antogs tre horisontella laster verka på staplingen: statiskt vattentryck, hydrodynamiskt vattentryck och drivgodslast. I arbetet har fyra stycken intervjuer med sakkunniga inom översvämningsområdetgenomförts. Intervjuerna gav en inblick i hur sakkunniga på berörda myndigheter ser på Sveriges beredskap, hantering, planering mot översvämningar och vilka kriterier för skyddsbarriärer som anses viktiga. Resultatet av arbetet visar att C3Cblock® till stor del klarar de vattenhastigheter och vattenhöjder som myndigheten för skydd och beredskap karterar för. Arbetet visar också att inverkan av drivgods har en relativt liten effekt jämfört med dethydrodynamiska- och hydrostatiska vattenlasten. Då beräkningsuppställningen varit i ideala förhållanden är det viktigt att vid användning av C3Cblock® i förebyggande syfte mot översvämningar ha kännedom kring terrängförhållanden som underlagsmaterial och marklutning.

Page generated in 0.0477 seconds