• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 18
  • 16
  • 1
  • 1
  • 1
  • Tagged with
  • 38
  • 12
  • 10
  • 10
  • 9
  • 9
  • 8
  • 8
  • 8
  • 7
  • 6
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avanços no processo de fabricação de microdispositivos analíticos e em seu acoplamento com a detecção condutométrica sem contato / Advances in the fabrication process of analytical microdevices and in their coupling with the contactless conductivity detection

Segato, Thiago Pinotti 13 May 2011 (has links)
Neste trabalho foram desenvolvidas tecnologias e novos processos de fabricação de microdispositivos analíticos visando o acoplamento desta plataforma microfluídica com a detecção condutométrica sem contato (C4D). Uma segunda etapa do trabalho concentrou esforços em melhorar os níveis de detectabilidade da C4D. Para tanto foi proposto um processo rápido e robusto para selagem de canais de vidro para produção de microdispositivos analíticos para eletroforese. Os canais de vidro foram fabricados por processo fotolitográfico e corrosão química em via úmida. Os microcanais obtidos foram selados contra outra lâmina de vidro previamente recoberta por uma membrana polimérica (PDMS) de 50 µm de espessura. Esta mesma membrana, além de promover a junção das placas de vidro, promoveu também o isolamento elétrico entre a solução no interior do canal microfluídico (de uma lâmina de vidro) e os eletrodos metálicos presentes no substrato de vidro oposto. Assim, foi possível acoplar a detecção condutométrica sem contato (C4D) com a plataforma eletroforética proposta. O desempenho analítico desta foi avaliado usando detecção por fluorescência induzida a laser (LIF) e C4D. Eficiência de aproximadamente 47000 pratos/m foi alcançada com boa repetibilidade chip-a-chip. Fluxo eletrosmótico (EOF) estável foi observado apesar da presença do material polimérico compondo parte da parede interna do canal. Com a metodologia proposta, um chip pode ser fabricado em menos de 120 min, já incluindo as etapas de gravação por fotolitografia, corrosão e selagem. Quando comparada à selagem térmica, além do ganho de tempo e facilidade no manuseio dos substratos, o método proposto não necessita de altas temperaturas e os dispositivos obtidos apresentam repetibilidade satisfatória para análises em diferentes dias e em diferentes microchips. A plataforma analítica desenvolvida foi utilizada em um estudo cinético no qual foi possível determinar os parâmetros cinéticos (Vmax = 12,64 mmol L-1 min-1 e KM = 23,8 mmol L-1) da reação de decomposição de ureia catalisada pela enzima urease. Na segunda etapa do trabalho, foi proposta a alteração de um parâmetro físico, a constante dielétrica, da membrana de PDMS usada como isolante de modo a obter um acoplamento capacitivo mais eficiente e como conseqüência uma melhor resposta no detector. Uma discussão teórica fez-se necessária a respeito do princípio de funcionamento da C4D. Os resultados obtidos com experimentos, nos quais a membrana de PDMS foi dopada com dióxido de titânio (TiO2), mostraram que a discussão sobre o funcionamento deste detector está de acordo com as considerações teóricas apresentadas neste trabalho, onde o sinal analítico é proporcional à capacitância e esta é proporcional à constante dielétrica na cela de detecção. Com esta alternativa foi possível reduzir os limites de detecção em experimentos de análise em fluxo de 385,5 para 14,7 µmol L-1 após adição de 50% em massa de TiO2 na membrana de PDMS. / In this thesis were presented technologies developed aiming new manufacturing processes for analytical microdevices by coupling of this microfluidic platform with capacitively coupled contactless conductivity detection (C4D). In a second stage of the work, we focused on improving the levels of detectability of C4D. We proposed a fast and robust process for sealing glass channels to produce analytical microdevices for electrophoresis. The glass channels were fabricated by photolithographic process and chemical wet etching. The obtained microchannels were sealed against another glass plate, which was previously coated with a 50-µm-thick membrane of poly(dimethylsiloxane) (PDMS). The purpose of this membrane, besides promoting the bonding of the two glass plates, was to act as an electrical insulator between the solution within the microfluidic channel on the top glass plate and the metal electrode present on the bottom glass chip. Thus it was possible to couple the contactless conductivity detection (C4D) with the electrophoretic platform proposed. The analytical performance was evaluated using both laser induced fluorescence (LIF) detection and C4D. Efficiency of about 47,000 plates/m was achieved with good chip-to-chip repeatability. Electroosmotic flow (EOF) was observed and stable despite the presence of polymer composing part of the inner wall of the channel. With the proposed methodology, a chip can be manufactured at less than 120 min, including the patterning step by photolithography, chemical etching, and sealing (bonding) step. When compared to the heat sealing procedure, in addition to time savings, and ease of handling of the substrates, the method does not require high temperatures, and the devices obtained show satisfactory repeatability analysis on different days and different microchips. The proposed analytical platform was used in a kinetic study in which it was possible to determine the kinetic parameters (Vmax = 12.64 mmol L-1 min-1 and KM = 23.8 mmol L-1) for the decomposition of urea catalyzed by the enzyme urease. In the second part of this thesis, it was proposed to change a physical parameter, the dielectric constant of the PDMS membrane used as an insulator, to achieve a more efficient capacitive coupling and consequently a better response in the detector. A theoretical discussion was required regarding the operating principle of C4D. The results obtained from experiments in which the PDMS membrane was doped with titanium dioxide (TiO2) showed that the discussion on the functioning of this detector is in agreement with the theoretical considerations presented in this work. The analytical signal was proportional to the capacitance and this was proportional to the dielectric constant in the detection cell. With this alternative we could reduce the detection limits in flow analysis system experiments from 385.5 to 14.7 µmol L-1 after addition of 50% wt of TiO2 in the PDMS membrane.
2

Avanços no processo de fabricação de microdispositivos analíticos e em seu acoplamento com a detecção condutométrica sem contato / Advances in the fabrication process of analytical microdevices and in their coupling with the contactless conductivity detection

Thiago Pinotti Segato 13 May 2011 (has links)
Neste trabalho foram desenvolvidas tecnologias e novos processos de fabricação de microdispositivos analíticos visando o acoplamento desta plataforma microfluídica com a detecção condutométrica sem contato (C4D). Uma segunda etapa do trabalho concentrou esforços em melhorar os níveis de detectabilidade da C4D. Para tanto foi proposto um processo rápido e robusto para selagem de canais de vidro para produção de microdispositivos analíticos para eletroforese. Os canais de vidro foram fabricados por processo fotolitográfico e corrosão química em via úmida. Os microcanais obtidos foram selados contra outra lâmina de vidro previamente recoberta por uma membrana polimérica (PDMS) de 50 µm de espessura. Esta mesma membrana, além de promover a junção das placas de vidro, promoveu também o isolamento elétrico entre a solução no interior do canal microfluídico (de uma lâmina de vidro) e os eletrodos metálicos presentes no substrato de vidro oposto. Assim, foi possível acoplar a detecção condutométrica sem contato (C4D) com a plataforma eletroforética proposta. O desempenho analítico desta foi avaliado usando detecção por fluorescência induzida a laser (LIF) e C4D. Eficiência de aproximadamente 47000 pratos/m foi alcançada com boa repetibilidade chip-a-chip. Fluxo eletrosmótico (EOF) estável foi observado apesar da presença do material polimérico compondo parte da parede interna do canal. Com a metodologia proposta, um chip pode ser fabricado em menos de 120 min, já incluindo as etapas de gravação por fotolitografia, corrosão e selagem. Quando comparada à selagem térmica, além do ganho de tempo e facilidade no manuseio dos substratos, o método proposto não necessita de altas temperaturas e os dispositivos obtidos apresentam repetibilidade satisfatória para análises em diferentes dias e em diferentes microchips. A plataforma analítica desenvolvida foi utilizada em um estudo cinético no qual foi possível determinar os parâmetros cinéticos (Vmax = 12,64 mmol L-1 min-1 e KM = 23,8 mmol L-1) da reação de decomposição de ureia catalisada pela enzima urease. Na segunda etapa do trabalho, foi proposta a alteração de um parâmetro físico, a constante dielétrica, da membrana de PDMS usada como isolante de modo a obter um acoplamento capacitivo mais eficiente e como conseqüência uma melhor resposta no detector. Uma discussão teórica fez-se necessária a respeito do princípio de funcionamento da C4D. Os resultados obtidos com experimentos, nos quais a membrana de PDMS foi dopada com dióxido de titânio (TiO2), mostraram que a discussão sobre o funcionamento deste detector está de acordo com as considerações teóricas apresentadas neste trabalho, onde o sinal analítico é proporcional à capacitância e esta é proporcional à constante dielétrica na cela de detecção. Com esta alternativa foi possível reduzir os limites de detecção em experimentos de análise em fluxo de 385,5 para 14,7 µmol L-1 após adição de 50% em massa de TiO2 na membrana de PDMS. / In this thesis were presented technologies developed aiming new manufacturing processes for analytical microdevices by coupling of this microfluidic platform with capacitively coupled contactless conductivity detection (C4D). In a second stage of the work, we focused on improving the levels of detectability of C4D. We proposed a fast and robust process for sealing glass channels to produce analytical microdevices for electrophoresis. The glass channels were fabricated by photolithographic process and chemical wet etching. The obtained microchannels were sealed against another glass plate, which was previously coated with a 50-µm-thick membrane of poly(dimethylsiloxane) (PDMS). The purpose of this membrane, besides promoting the bonding of the two glass plates, was to act as an electrical insulator between the solution within the microfluidic channel on the top glass plate and the metal electrode present on the bottom glass chip. Thus it was possible to couple the contactless conductivity detection (C4D) with the electrophoretic platform proposed. The analytical performance was evaluated using both laser induced fluorescence (LIF) detection and C4D. Efficiency of about 47,000 plates/m was achieved with good chip-to-chip repeatability. Electroosmotic flow (EOF) was observed and stable despite the presence of polymer composing part of the inner wall of the channel. With the proposed methodology, a chip can be manufactured at less than 120 min, including the patterning step by photolithography, chemical etching, and sealing (bonding) step. When compared to the heat sealing procedure, in addition to time savings, and ease of handling of the substrates, the method does not require high temperatures, and the devices obtained show satisfactory repeatability analysis on different days and different microchips. The proposed analytical platform was used in a kinetic study in which it was possible to determine the kinetic parameters (Vmax = 12.64 mmol L-1 min-1 and KM = 23.8 mmol L-1) for the decomposition of urea catalyzed by the enzyme urease. In the second part of this thesis, it was proposed to change a physical parameter, the dielectric constant of the PDMS membrane used as an insulator, to achieve a more efficient capacitive coupling and consequently a better response in the detector. A theoretical discussion was required regarding the operating principle of C4D. The results obtained from experiments in which the PDMS membrane was doped with titanium dioxide (TiO2) showed that the discussion on the functioning of this detector is in agreement with the theoretical considerations presented in this work. The analytical signal was proportional to the capacitance and this was proportional to the dielectric constant in the detection cell. With this alternative we could reduce the detection limits in flow analysis system experiments from 385.5 to 14.7 µmol L-1 after addition of 50% wt of TiO2 in the PDMS membrane.
3

Bullous pemphigoid: Use of C4d Immunofluorescent Staining in a Case With Repeated Negative Conventional Direct Immunofluorescence Studies

Kassaby, Sarah S., Hicks, Alexander, Leicht, Stuart, Youngberg, George A. 01 January 2017 (has links)
Direct immunofluorescence (DIF) using frozen section material from a fresh/preserved perilesional biopsy is the gold standard for the immunopathologic diagnosis of bullous pemphigoid (BP). DIF in BP shows linear dermoepidermal junction (DEJ) staining for C3, with or without staining for IgG. In some situations, only a formalin-fixed lesional biopsy is obtained (with no fresh/preserved perilesional biopsy for DIF). In this setting, paraffin section C4d immunohistochemistry has proven to be diagnostically useful, demonstrating linear DEJ positivity for C4d. We present a novel use of C4d staining for the diagnosis of BP, specifically analyzing C4d perilesional frozen section DIF in a case where standard perilesional frozen section DIF for IgG/C3 was available, but was negative. An 80-year-old woman presented with a pruritic bullous lesion on her left upper extremity, clinically thought to represent BP. Lesional histologic findings were typical for BP, but perilesional frozen section DIF staining was negative for IgG and C3. A second set of biopsies processed at a different laboratory yielded the same result. A diagnosis of bullous scabies was considered. Subsequently, perilesional frozen section DIF for C4d was obtained, which showed strong linear DEJ positivity, confirming the diagnosis of BP. DIF for C4d is widely used in transplant pathology, since C4d is persistent in tissue, versus C3. Our case demonstrates that perilesional frozen section DIF staining for C4d may be positive and diagnostic in BP, even when conventional DIF staining for IgG and C3 is negative.
4

Desenvolvimento de sensores e de métodos analíticos para determinação de compostos de interesse farmacêutico / Development of sensors and analytical methods for determination of compounds of pharmaceutical relevance

Silva, Iranaldo Santos da 11 October 2013 (has links)
A crescente demanda por produtos farmacêuticos tem como consequência a necessidade de elaboração de novos procedimentos analíticos que, via de regra, apresentem características como: elevada frequência analítica, simplicidade, ausência de substâncias altamente tóxicas, e com baixo custo para o controle de qualidade dos fármacos lançados no mercado. Neste trabalho descreve-se o desenvolvimento de procedimentos para determinação de N-acetilcisteína (NAC), nimesulida (NMS), trimetoprima (TMP) e sulfametoxazol (SMX) em formulações farmacêuticas usando técnicas eletroanalíticas e métodos de separação. Na determinação da NAC foi usado um eletrodo de grafite pirolítico modificado com ftalocianina de cobalto (CoPc) em 0,1 mol L-1 de NaOH. Este sensor mostrou intensa catálise para NAC produzindo um aumento na corrente anódica de cerca de 700 vezes quando comparado com o eletrodo limpo. Um procedimento em FIA foi proposto usando este sensor, e a curva analítica foi linear no intervalo 5,0 × 10-5 a 1,0 × 10-3 mol L-1, com coeficiente de correlação maior que 0,999. O DPR de 1,1% (n = 13) foi obtido para uma solução contendo 5,0 × 10-4 mol L-1 de NAC. Além disso o método apresentou LD e LQ de 9,0 ×10-7 mol L-1 e 3,0 × 10-6 mol L-1, respectivamente. A determinação eletroanalítica de NMS foi conduzida em solução de 1,0 mol L-1 de NaOH usando eletrodo de carbono vítreo, meio em que não ocorre envenenamento da superfície do eletrodo. Desse modo, um método eletroanalítico usando voltametria de onda quadrada foi elaborado para análise de NMS. Nas condições ótimas de análise o método apresentou uma faixa linear no intervalo de 4,3 × 10-5 a 4,2 × 10-4 mol L-1, com limite de detecção de 3,2 × 10-6 mol L-1. A precisão do método foi avaliada em um mesmo dia de análise por sucessivas medidas voltamétricas (n = 10) em solução de hidróxido de sódio 1,0 mol L-1 contendo 1,0 × 10-4 mol L-1 de NMS, sem a necessidade de renovação da superfície do eletrodo. Os resultados para esta série de medidas foram avaliados e o DPR calculado foi somente 1,2%, indicando que nessas condições o eletrodo apresentou uma resposta estável além de não sofrer qualquer efeito de envenenamento. Para a determinação simultânea de TMP e SMX foi desenvolvido um método analítico empregando eletroforese capilar com detecção condutométrica sem contato (C4D). Usando uma solução 10 mmol L-1 lítio-fosfato (pH 7,1 ) como tampão de corrida, a faixa linear de trabalho obtida para ambos os analitos foi de 12,5 a 200 × 10-6 mol L-1 com R > 0,999. Nas condições de análise foram obtidos LDs de 1,1 × 10-6 mol L-1 para a TMP, e 3,3 × 10-6 mol L-1 para o SMX com um tempo total de análise de 2,6 minutos. / The growing demand for pharmaceutical products has created need for developing new analytical procedures that, as a rule, exhibit characteristics like, high sampling rate, simplicity, absence of highly toxic substances, and low cost for quality control of drugs launched in market. In this work, electroanalytical and capillary electrophoresis methods for determination of N-acetylcysteine (NAC), nimesulide (NMS), trimethoprim (TMP) and sulfamethoxazole (SMX) in pharmaceutical formulations were proposed. For NAC determinations a pyrolytic graphite electrode modified with CoPc in 0.1 mol L-1 NaOH was used. This new sensor showed to be catalytic for this compound producing an anodic current increase of 700 times when compared with bare electrode. A FIA procedure was proposed using this new sensor, and the method showed a linear response in a range of 5.0 × 10-5 to 1.0 × 10-3 mol L-1 with correlation coefficient better than 0.999. RSD of 1.1% (n = 13) was obtained for a solution containing 5.0 × 10-4 mol L-1 NAC. Furthermore the method presented DL and QL of 9.0 × 10-7 mol L-1 and 3.0 × 10-6 mol L-1, respectively. NMS electroanalytical determination was conducted in a 1.0 mol L-1 NaOH solution using a glassy carbon electrode. In strongly alkaline medium it was verified that NMS does not produce poisoning of the electrode surface. Thus an electroanalytical method using square wave voltammetry was proposed for analysis of NMS. In the optimal analysis conditions proposed method showed a linear response in a range of 4.3 × 10-5 to 4.2 × 10-4 mol L-1, with detection limit of 3.2 × 10-6 mol L-1. Accuracy of the method was evaluated on the same day by successive voltammetric measurements (n = 10) in a 1.0 mol L-1 sodium hydroxide solution containing 1.0 × 10-4 mol L-1 of NMS without the needing to renew electrode surface. Results for this series of measures were calculated and standard deviation was of only 1.2%, suggesting that in these conditions the electrode showed a stable response in addition to suffer no poisoning effects. For simultaneous determination of TMP and SMX an analytical method using capillary electrophoresis with contactless conductivity detection (C4D) was developed. Using a 10 mmol L-1 lithium-phosphate (pH 7.1) solution as running buffer, a linear response range for both analytes was obtained ranging through 12.5 to 200 × 10-6 mol L-1 with R> 0.999. Under these analysis conditions, DL of 1.1 × 10-6 mol L-1 for TMP, and 3.3 × 10-6 mol L-1 for SMX were obtained, with a total analysis time of only 2.6 minutes.
5

Desenvolvimento e validação de método para análise do topiramato em amostras de plasma por eletroforese capilar com detecção UV/vis e C4D / Development and validation of method for analysis of topiramate in plasma samples by capillary electrophoresis with UV/vis and C4D detection

Ishikawa, Aline Akemi 20 April 2016 (has links)
O topiramato (TPM) é um fármaco antiepiléptico utilizado para o controle de crises epilépticas generalizadas e parciais em adultos e crianças. A determinação da concentração plasmática do TPM em associação com as observações clínicas é de suma importância, uma vez que permite o ajuste individual da dose administrada ao paciente, diminuindo a incidência de reações adversas e melhorando a adesão ao tratamento. No presente trabalho, dois métodos bioanalíticos foram desenvolvidos e validados para análise do TPM em amostras de plasma, por eletroforese capilar utilizando os detectores DAD (detecção indireta) e C4D Lite (detecção condutométrica). A análise eletroforética para ambos os métodos foi realizada em um capilar de sílica fundida de 75 ?m de diâmetro interno e 40 cm de comprimento efetivo. O eletrólito de corrida foi composto por trietanolamina (TEA) 15 mmol L-1 para a detecção condutométrica e TEA 15 mmol L-1, ácido 3,5 dinitrobenzóico (DNB) 5 mmol L-1 e brometo de cetiltrimetilamônio (CTAB) 0,4 mmol L-1 para detecção indireta. As injeções foram feitas no modo hidrodinâmico a 0,8 psi por 5 segundos e a tensão aplicada foi de -20 e 20 kV para detecção indireta e condutométrica, respectivamente. Nestas condições, o TPM migrou em 2,5 min. O preparo das amostras foi realizado por extração líquido-líquido (LLE), usando éter metil-terc-butílico (MTBE) como solvente extrator e utilizando 500 e 200 ?L de plasma para o método com detecção indireta e condutométrica, respectivamente. Os métodos foram validados de acordo com os guias oficiais da Agência Nacional de Vigilância Sanitária e European Medicine Agency e apresentaram linearidade no intervalo de concentração plasmática de 1-30 ?g mL-1 e valores de precisão e exatidão abaixo de 15 %, além de serem seletivos. Assim, ambos os métodos foram aplicados com sucesso em amostras de plasma de pacientes em tratamento com o TPM. Embora os detectores universais geralmente apresentem um maior limite de detecção comparado com detectores seletivos, o método com detecção condutométrica desenvolvido neste trabalho apresentou como vantagem maior sensibilidade em relação método indireto (DAD). Além disso, apresentou também vantagens como simplicidade e baixo custo, mostrando viabilidade na aplicação para análises de rotina. / Topiramate (TPM) is an antiepileptic drug that has been used as an agent for the control of partial and generalized seizures in both adults and children patients. The determination of the plasmatic concentration of TPM in association with clinical observations is of utmost importance for the individual adjustment of the administered dose to the patient. In the present work, two bioanalytical methods have been developed and validated for TPM analysis in plasma samples by capillary electrophoresis using DAD (indirect detection) and C4D Lite detectors (conductometric detection). The electrophoretic analysis for both methods were performed on a fused silica capillary of 75 ?m of internal diameter and 40 cm effective length. The background electrolyte was composed of triethanolamine (TEA) 15 mmol L-1 for conductometric detection and TEA 15 mmol L-1, 3,5 dinitrobenzoic acid (DNB) 5 mmol L-1 and cetyltrimethylammonium bromide (CTAB) 0.4 mmol -1 for indirect detection. The injections were carried out in hydrodynamic mode, at 0.8 psi for 5 seconds, and the voltage applied were -20 e 20 kV for indirect and conductometric detection, respectively. Under these conditions, TPM migrated in 2.5 min. The sample preparation was carried out by liquid liquid extraction (LLE) using methyl tert-butyl ether (MTBE) as solvent, and using 500 and 200 ?L of plasma samples for direct and conductometric detection, respectively. The methods were validated according to the official guides of the Agência Nacional de Vigilância Sanitária and European Medicine Agency, and showed linearity in plasmatic concentration range of 1-30 mg L-1, precision and accuracy values below 15%, beside selectivity. Both methods have been applied successfully to analysis of plasma samples of patients in treatment with TPM. Although universal detectors have a higher quantification limit compared with selective detectors, the method with conductometric detection developed in this work presented greater sensitivity than indirect method (DAD). Furthermore, it also presented advantages such as simplicity and low cost, showing feasibility in applying to routine analysis.
6

Desenvolvimento de sensores e de métodos analíticos para determinação de compostos de interesse farmacêutico / Development of sensors and analytical methods for determination of compounds of pharmaceutical relevance

Iranaldo Santos da Silva 11 October 2013 (has links)
A crescente demanda por produtos farmacêuticos tem como consequência a necessidade de elaboração de novos procedimentos analíticos que, via de regra, apresentem características como: elevada frequência analítica, simplicidade, ausência de substâncias altamente tóxicas, e com baixo custo para o controle de qualidade dos fármacos lançados no mercado. Neste trabalho descreve-se o desenvolvimento de procedimentos para determinação de N-acetilcisteína (NAC), nimesulida (NMS), trimetoprima (TMP) e sulfametoxazol (SMX) em formulações farmacêuticas usando técnicas eletroanalíticas e métodos de separação. Na determinação da NAC foi usado um eletrodo de grafite pirolítico modificado com ftalocianina de cobalto (CoPc) em 0,1 mol L-1 de NaOH. Este sensor mostrou intensa catálise para NAC produzindo um aumento na corrente anódica de cerca de 700 vezes quando comparado com o eletrodo limpo. Um procedimento em FIA foi proposto usando este sensor, e a curva analítica foi linear no intervalo 5,0 × 10-5 a 1,0 × 10-3 mol L-1, com coeficiente de correlação maior que 0,999. O DPR de 1,1% (n = 13) foi obtido para uma solução contendo 5,0 × 10-4 mol L-1 de NAC. Além disso o método apresentou LD e LQ de 9,0 ×10-7 mol L-1 e 3,0 × 10-6 mol L-1, respectivamente. A determinação eletroanalítica de NMS foi conduzida em solução de 1,0 mol L-1 de NaOH usando eletrodo de carbono vítreo, meio em que não ocorre envenenamento da superfície do eletrodo. Desse modo, um método eletroanalítico usando voltametria de onda quadrada foi elaborado para análise de NMS. Nas condições ótimas de análise o método apresentou uma faixa linear no intervalo de 4,3 × 10-5 a 4,2 × 10-4 mol L-1, com limite de detecção de 3,2 × 10-6 mol L-1. A precisão do método foi avaliada em um mesmo dia de análise por sucessivas medidas voltamétricas (n = 10) em solução de hidróxido de sódio 1,0 mol L-1 contendo 1,0 × 10-4 mol L-1 de NMS, sem a necessidade de renovação da superfície do eletrodo. Os resultados para esta série de medidas foram avaliados e o DPR calculado foi somente 1,2%, indicando que nessas condições o eletrodo apresentou uma resposta estável além de não sofrer qualquer efeito de envenenamento. Para a determinação simultânea de TMP e SMX foi desenvolvido um método analítico empregando eletroforese capilar com detecção condutométrica sem contato (C4D). Usando uma solução 10 mmol L-1 lítio-fosfato (pH 7,1 ) como tampão de corrida, a faixa linear de trabalho obtida para ambos os analitos foi de 12,5 a 200 × 10-6 mol L-1 com R > 0,999. Nas condições de análise foram obtidos LDs de 1,1 × 10-6 mol L-1 para a TMP, e 3,3 × 10-6 mol L-1 para o SMX com um tempo total de análise de 2,6 minutos. / The growing demand for pharmaceutical products has created need for developing new analytical procedures that, as a rule, exhibit characteristics like, high sampling rate, simplicity, absence of highly toxic substances, and low cost for quality control of drugs launched in market. In this work, electroanalytical and capillary electrophoresis methods for determination of N-acetylcysteine (NAC), nimesulide (NMS), trimethoprim (TMP) and sulfamethoxazole (SMX) in pharmaceutical formulations were proposed. For NAC determinations a pyrolytic graphite electrode modified with CoPc in 0.1 mol L-1 NaOH was used. This new sensor showed to be catalytic for this compound producing an anodic current increase of 700 times when compared with bare electrode. A FIA procedure was proposed using this new sensor, and the method showed a linear response in a range of 5.0 × 10-5 to 1.0 × 10-3 mol L-1 with correlation coefficient better than 0.999. RSD of 1.1% (n = 13) was obtained for a solution containing 5.0 × 10-4 mol L-1 NAC. Furthermore the method presented DL and QL of 9.0 × 10-7 mol L-1 and 3.0 × 10-6 mol L-1, respectively. NMS electroanalytical determination was conducted in a 1.0 mol L-1 NaOH solution using a glassy carbon electrode. In strongly alkaline medium it was verified that NMS does not produce poisoning of the electrode surface. Thus an electroanalytical method using square wave voltammetry was proposed for analysis of NMS. In the optimal analysis conditions proposed method showed a linear response in a range of 4.3 × 10-5 to 4.2 × 10-4 mol L-1, with detection limit of 3.2 × 10-6 mol L-1. Accuracy of the method was evaluated on the same day by successive voltammetric measurements (n = 10) in a 1.0 mol L-1 sodium hydroxide solution containing 1.0 × 10-4 mol L-1 of NMS without the needing to renew electrode surface. Results for this series of measures were calculated and standard deviation was of only 1.2%, suggesting that in these conditions the electrode showed a stable response in addition to suffer no poisoning effects. For simultaneous determination of TMP and SMX an analytical method using capillary electrophoresis with contactless conductivity detection (C4D) was developed. Using a 10 mmol L-1 lithium-phosphate (pH 7.1) solution as running buffer, a linear response range for both analytes was obtained ranging through 12.5 to 200 × 10-6 mol L-1 with R> 0.999. Under these analysis conditions, DL of 1.1 × 10-6 mol L-1 for TMP, and 3.3 × 10-6 mol L-1 for SMX were obtained, with a total analysis time of only 2.6 minutes.
7

Desenvolvimento e validação de método para análise do topiramato em amostras de plasma por eletroforese capilar com detecção UV/vis e C4D / Development and validation of method for analysis of topiramate in plasma samples by capillary electrophoresis with UV/vis and C4D detection

Aline Akemi Ishikawa 20 April 2016 (has links)
O topiramato (TPM) é um fármaco antiepiléptico utilizado para o controle de crises epilépticas generalizadas e parciais em adultos e crianças. A determinação da concentração plasmática do TPM em associação com as observações clínicas é de suma importância, uma vez que permite o ajuste individual da dose administrada ao paciente, diminuindo a incidência de reações adversas e melhorando a adesão ao tratamento. No presente trabalho, dois métodos bioanalíticos foram desenvolvidos e validados para análise do TPM em amostras de plasma, por eletroforese capilar utilizando os detectores DAD (detecção indireta) e C4D Lite (detecção condutométrica). A análise eletroforética para ambos os métodos foi realizada em um capilar de sílica fundida de 75 ?m de diâmetro interno e 40 cm de comprimento efetivo. O eletrólito de corrida foi composto por trietanolamina (TEA) 15 mmol L-1 para a detecção condutométrica e TEA 15 mmol L-1, ácido 3,5 dinitrobenzóico (DNB) 5 mmol L-1 e brometo de cetiltrimetilamônio (CTAB) 0,4 mmol L-1 para detecção indireta. As injeções foram feitas no modo hidrodinâmico a 0,8 psi por 5 segundos e a tensão aplicada foi de -20 e 20 kV para detecção indireta e condutométrica, respectivamente. Nestas condições, o TPM migrou em 2,5 min. O preparo das amostras foi realizado por extração líquido-líquido (LLE), usando éter metil-terc-butílico (MTBE) como solvente extrator e utilizando 500 e 200 ?L de plasma para o método com detecção indireta e condutométrica, respectivamente. Os métodos foram validados de acordo com os guias oficiais da Agência Nacional de Vigilância Sanitária e European Medicine Agency e apresentaram linearidade no intervalo de concentração plasmática de 1-30 ?g mL-1 e valores de precisão e exatidão abaixo de 15 %, além de serem seletivos. Assim, ambos os métodos foram aplicados com sucesso em amostras de plasma de pacientes em tratamento com o TPM. Embora os detectores universais geralmente apresentem um maior limite de detecção comparado com detectores seletivos, o método com detecção condutométrica desenvolvido neste trabalho apresentou como vantagem maior sensibilidade em relação método indireto (DAD). Além disso, apresentou também vantagens como simplicidade e baixo custo, mostrando viabilidade na aplicação para análises de rotina. / Topiramate (TPM) is an antiepileptic drug that has been used as an agent for the control of partial and generalized seizures in both adults and children patients. The determination of the plasmatic concentration of TPM in association with clinical observations is of utmost importance for the individual adjustment of the administered dose to the patient. In the present work, two bioanalytical methods have been developed and validated for TPM analysis in plasma samples by capillary electrophoresis using DAD (indirect detection) and C4D Lite detectors (conductometric detection). The electrophoretic analysis for both methods were performed on a fused silica capillary of 75 ?m of internal diameter and 40 cm effective length. The background electrolyte was composed of triethanolamine (TEA) 15 mmol L-1 for conductometric detection and TEA 15 mmol L-1, 3,5 dinitrobenzoic acid (DNB) 5 mmol L-1 and cetyltrimethylammonium bromide (CTAB) 0.4 mmol -1 for indirect detection. The injections were carried out in hydrodynamic mode, at 0.8 psi for 5 seconds, and the voltage applied were -20 e 20 kV for indirect and conductometric detection, respectively. Under these conditions, TPM migrated in 2.5 min. The sample preparation was carried out by liquid liquid extraction (LLE) using methyl tert-butyl ether (MTBE) as solvent, and using 500 and 200 ?L of plasma samples for direct and conductometric detection, respectively. The methods were validated according to the official guides of the Agência Nacional de Vigilância Sanitária and European Medicine Agency, and showed linearity in plasmatic concentration range of 1-30 mg L-1, precision and accuracy values below 15%, beside selectivity. Both methods have been applied successfully to analysis of plasma samples of patients in treatment with TPM. Although universal detectors have a higher quantification limit compared with selective detectors, the method with conductometric detection developed in this work presented greater sensitivity than indirect method (DAD). Furthermore, it also presented advantages such as simplicity and low cost, showing feasibility in applying to routine analysis.
8

Komplement-vážící protilátky u pacientů po transplantaci orgánů a jejich klinický význam / Complement-binding antibodies in patients after organ transplantation and their clinical relevance

Kovandová, Barbora January 2018 (has links)
The diagnosis of antibody-mediated rejection after liver transplantation is complicated, due to the fact that the clinical and pathological signs of this life- threatening complication are often overlapping with non-immunological symptoms, like biliary obstruction, ischemia, thrombosis and others. Furthermore, the transplanted liver is to a great extent resistant to this type of rejection. Like in the transplanted kidney and heart, the main pathological factors of graft injury are antibodies directed to the mismatched HLA antigens of the organ donor, i.e. donor- specific antibodies. Besides analysis of HLA specificity of antibodies, research lately has been directed to define whether these antibodies are complement-binding or not. Literature data on this are however up till now limited. Therefore, the aim of this diploma thesis was to study the clinical relevance of complement-binding antibodies against HLA antigens in patients after liver transplantation. Our preliminary results suggest that there might be a correlation between the presence of complement-binding antibodies and the development of antibody-mediated rejection. This finding may play a role for improvement of the prognosis of patients after liver transplantation. Key words HLA, antibodies, C4d, complement, liver transplantation
9

Application of Complement Component 4d Immunohistochemistry to ABO-Compatible and ABO-Incompatible Liver Transplantation / ABO血液型適合および不適合肝移植に対する補体成分C4d免疫染色の応用

Salah, Adeeb Ahmed Kassim 23 March 2015 (has links)
京都大学 / 0048 / 新制・課程博士 / 博士(医学) / 甲第18871号 / 医博第3982号 / 新制||医||1008(附属図書館) / 31822 / 京都大学大学院医学研究科医学専攻 / (主査)教授 川口 義弥, 教授 三森 経世, 教授 髙折 晃史 / 学位規則第4条第1項該当 / Doctor of Medical Science / Kyoto University / DFAM
10

A discourse analysis of online media reporting on the Global Entrepreneurship Summit 2015 in Nairobi

Holst, Paula January 2016 (has links)
A capitalist world system is dictating how the global economy is organised, and entrepreneurship is suggested as a global solution for economic development. In development practices bottom up approaches such as social entrepreneurship are challenging the traditional donor-based model. The Global Entrepreneurship Summit (GES) is a United States lead initiative to promote entrepreneurship and economic ties with the Western world. This study analyses the online media discussion around the GES 2015 held in Nairobi, with focus on answering how sampled Kenyan blog and online news articles construct and contribute to Kenyan entrepreneurship discourse with their reporting around the GES, whether they reflect a more global or local capitalist narrative, and finally what kind of development thinking the entrepreneurship discourse reflects. A literature review builds context by describing the development of the Kenyan capitalist narrative. The empirical part applies a mixed method approach, with elements from content as well as discourse analysis in studying a sample of 120 Kenyan blog and online news articles. The analysis reveals that the local online reporting around the GES reflects a global capitalist narrative with a highly optimistic attitude towards entrepreneurship as a means to create economic growth as well as social change.

Page generated in 0.0201 seconds