• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 141
  • 115
  • 32
  • 28
  • 14
  • 9
  • 8
  • 6
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 402
  • 402
  • 159
  • 74
  • 60
  • 48
  • 37
  • 35
  • 34
  • 30
  • 29
  • 29
  • 28
  • 28
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
261

Study of fixturing accessibilities in computer-aided fixture design

Ghatpande, Puja Sudhakar. January 2008 (has links)
Thesis (M.S.)--Worcester Polytechnic Institute. / Keywords: Accessibility; CAM; CAD; Integration; Fixture Design. Includes bibliographical references (leaves 108-109).gh
262

Computer-aided manufacturing planning (CAMP) of mass customization for non-rotational part production

Yao, Suqin. January 2003 (has links)
Dissertation (Ph.D.) -- Worcester Polytechnic Institute. / Keywords: Computer aided manufacturing planning; Object-oriented systems analysis (OSA); Feature; manufacturing resource capability; setup planning; multi-part fixture Includes bibliographical references (p.146-154).
263

A platform independent process data exchange mechanism between Java applications and computer aided manufacturing systems

Jain, Vikesh. January 2003 (has links)
Thesis (M.S.)--Ohio University, November, 2003. / Title from PDF t.p. Includes bibliographical references (p. 112-115)
264

Uma interface CAD/CAM para a programação fora de linha de robôs industriais /

Toledo, Leonardo Bastos de January 2000 (has links)
Dissertação (Mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. / Made available in DSpace on 2012-10-17T16:46:13Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-25T19:05:52Z : No. of bitstreams: 1 153197.pdf: 37503010 bytes, checksum: 7071c8230ef8fb598c64ed0bad9ba552 (MD5) / Este trabalho trata do problema do planejamento e programação de trajetórias em manipuladores servo controlados, com ênfase no uso das técnicas de projeto e de manufatura auxiliadas por computador (CAD/CAM). A proposição consiste em usar a informação geométrica do contorno do produto, obtida a partir da modelagem de superfícies bi-paramétricas em sistemas CAD, em procedimentos de planejamento de trajetórias. Estes procedimentos, desenvolvidos e integrados, fazem uso de formulações de curvas e superfícies "B-splines". A meta principal do trabalho é efetuar a análise e a programação de atividades de robôs industriais em processos de fabricação que envolvam um movimento contínuo do efetuador, tais como a pintura, o polimento, o desbaste e a soldagem.
265

Um sistema computacional inteligente de suporte ao projeto, manufatura e montagem de peças baseado em features :: uma abordagem com sistemas especialistas /

Maziero, Nilson Luiz January 1998 (has links)
Tese (Doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico. / Made available in DSpace on 2012-10-17T06:52:53Z (GMT). No. of bitstreams: 0Bitstream added on 2016-01-09T00:28:08Z : No. of bitstreams: 1 142447.pdf: 18276024 bytes, checksum: f501e693472845b2529a876dcae980b9 (MD5)
266

Mechanical properties of interim restorative materials: conventional vs. CAD/CAM

Odisho, Walter E. 25 October 2017 (has links)
To determine the effects of thermal accelerated aging on flexural strength and flexural modulus of conventional and CAD/CAM provisional crown and bridge restorative materials. Six provisional crown and bridge materials were selected for this study. Three conventional resins: Jet Set 4 (Lang), Luxatemp (DMG), and Protemp Plus (3M ESPE); and three CAD/CAM materials: ArtBloc Temp (Merz), Telio CAD-Temp (Ivoclar Vivadent), and Vita CAD-Temp (Vita). Specimens of conventional materials were fabricated using a custom-made aluminum mold 25 2 2 mm. CAD/CAM blocks were sectioned to the same dimensions. A total of 180 bar-shaped specimens were obtained (30 of each material) and were divided into three groups per treatment. Groups 1 and 2 were immersed in 37°C water for 24 hours, and 6 days, respectively. Group 3 was subjected to 5,000 thermal cycles between 5°C and 55°C in water with 35 seconds dwelling time. All specimens where tested for flexural properties using three-point bending protocol on an Instron 5566A at a crosshead speed of 0.5mm/min. The results were analyzed by one-way ANOVA and post hoc Tukey test with material type and aging conditions as the main variables. Significance level was set at (p<0.05).  Overall CAD/CAM materials demonstrated significantly higher flexural strength and flexural modulus over conventional resins. No significant difference in flexural strength and flexural modulus was found among three treatments except for: Luxatemp, which showed significant increased flexural strength and flexural modulus after thermal cycling, and Protemp Plus which showed increased flexural strength after 6 days of water storage.
267

Novo design de laminados oclusais ultrafinos CAD/CAM de resina composta e cerâmica para o tratamento de erosão severa

Schlichting, Luís Henrique 25 October 2012 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2010 / Made available in DSpace on 2012-10-25T08:25:08Z (GMT). No. of bitstreams: 1 280998.pdf: 13547339 bytes, checksum: d62cc0e1bee0e5716306243680126639 (MD5) / O objetivo deste estudo foi avaliar a influência de materiais para processamento CAD/CAM (cerâmica vs. resina composta) na resistência à fadiga de laminados oclusais ultrafinos (0,6 mm) e finos (1,2 mm). Setenta molares extraídos receberam um preparo não retentivo padronizado (simulando erosão oclusal avançada) onde o esmalte oclusal foi removido e a dentina exposta foi imediatamente selada (Optibond FL). Por intermédio do sistema Cerec 3 (Sirona), 40 dentes foram restaurados com laminados oclusais de 0,6 mm de espessura e 30 deles com 1,2 mm de espessura. As cerâmicas reforçadas Empress CAD (grupos ECAD06 e ECAD12) e e.max CAD (grupos EMAX06 e EMAX12) e a resina composta Paradigm MZ100 (grupos MZ06 e MZ12) foram utilizadas na usinagem das restaurações (n=10). Uma resina composta experimental (grupo XR06) também foi incluída somente para a espessura 0,6 mm (n=10). A superfície interna das restaurações foi condicionada com ácido fluorídrico e silanizada (cerâmicas) ou microjateada com óxido de alumínio e silanizada (resinas compostas). Os preparos foram microjateados e condicionados com ácido fosfórico antes da inserção das restaurações. Todas as restaurações foram cimentadas adesivamente pré-aquecendo-se a resina composta Filtek Z100. Esforços cíclicos isométricos foram aplicados à frequência de 5 Hz, iniciando com uma carga de 200 N (5000x) seguido por estágios de 400, 600, 800, 1000, 1200 e 1400 N a um máximo de 30.000 ciclos cada. O número de ciclos quando ocorreu a falha inicial (primeiras trincas) foi registrado. Os espécimes foram ciclados até a ocorrência de uma falha catastrófica (perda de 20 fragmento da restauração) ou até um máximo de 185.000 ciclos. Os grupos foram comparados pelo método Kaplan-Meier (P=0,008 para os grupos/0,6 mm e P=0,016 para os grupos/1,2 mm; corrigido por Bonferroni). Os resultados revelaram que: 1) para os grupos 0,6 mm Empress CAD e e.max apresentaram a falha inicial a uma carga média de 500 N e 800 N, respectivamente e nenhum dos espécimes sobreviveu aos 185.000 ciclos (sobrevivência de 0%); com os materiais MZ100 and XR a taxa de sobrevivência foi de 60% e 100%, respectivamente; 2) para os grupos 1,2 mm Empress CAD falharam a uma carga média de 900 N, e nenhum dos espécimes sobreviveu a todos os 185.000 ciclos de carga (sobrevivência de 0%); com e.max CAD e MZ100 a taxa de sobrevivência foi de 30% e 100%, respectivamente. As duas resinas compostas MZ100 and XR aumentaram a resistência à fadiga dos laminados oclusais ultrafinos (P<0,001) quando comparados ao Empress CAD and e.max. A resina composta MZ100 aumentou a resistência à fadiga dos laminados oclusais finos (P<0,002) quando comparada aos materiais Empress CAD e e.max CAD. / The aim of this study was to assess the influence of CAD/CAM restorative material (ceramic vs. composite resin) on the fatigue resistance of ultra-thin (0.6 mm-thick) and thin (1.2 mm-thick) occlusal veneers. Seventy extracted molars received a standardized nonretentive tooth preparation (simulating advanced occlusal erosion) including removal of occlusal enamel and immediate dentin sealing (Optibond FL). Using Cerec 3 (Sirona) forty teeth were restored with a 0.6 mm-thick occlusal veneer and 30 teeth with a 1.2 mm-thick. The reinforced ceramics Empress CAD (groups ECAD06 and ECAD12) and e.max CAD (groups EMAX06 and EMAX12) and the composite resins Paradigm MZ100 (groups MZ06 and MZ12) were used to mill the restorations (n=10). An experimental block (group XR06) was also included only for 0.6 mm-thick occlusal veneers (n=10). The intaglio surfaces were HF-etched and silanated (reinforced ceramics) or airborne-particle abraded and silanated (composite resins). Preparations were airborne-particle abraded and etched before restoration insertion. All restorations were adhesively luted with preheated Filtek Z100. Cyclic isometric chewing was applied at 5 Hz, starting with a load of 200 N (5,000X), followed by stages of 400, 600, 800, 1000, 1200 and 1,400 N at a maximum of 30,000 cycles each. The number of cycles at initial failure (first cracks) was recorded. Samples were loaded until catastrophic failure (lost restoration fragment) or to a maximum of 185,000 cycles. Groups were compared using the Kaplan-Meier survival curves (P=.008 for 0.6 mm-groups and P=0.016 for 1.2 mm-groups, Bonferroni-corrected). The results revealed that: 1) for 0.6 mm-thick occlusal veneers Empress CAD and e.max initially failed at an average load of 500 N and 800 N, respectively and none of them withstood all 185,000 load cycles (survival 0%); with MZ100 and XR the survival rate was 60% and 100%, respectively. 2) for 1.2 mmthick occlusal veneers Empress CAD failed at an average load of 900 N, and none of them withstood all 185,000 load cycles (survival 0%); with e.max CAD and MZ100 survival rate was 30% and 100%, respectively. Both composite resins MZ100 and XR increased the fatigue resistance of ultra-thin occlusal veneers (P<.001) when compared to Empress CAD and e.max. Composite resin MZ100 increased the fatigue resistance of thin occlusal veneers (P<.002) when compared to Empress CAD and e.max CAD. The aim of this study was to assess the influence of CAD/CAM restorative material (ceramic vs. composite resin) on the fatigue resistance of ultra-thin (0.6 mm-thick) and thin (1.2 mm-thick) occlusal veneers. Seventy extracted molars received a standardized nonretentive tooth preparation (simulating advanced occlusal erosion) including removal of occlusal enamel and immediate dentin sealing (Optibond FL). Using Cerec 3 (Sirona) forty teeth were restored with a 0.6 mm-thick occlusal veneer and 30 teeth with a 1.2 mm-thick. The reinforced ceramics Empress CAD (groups ECAD06 and ECAD12) and e.max CAD (groups EMAX06 and EMAX12) and the composite resins Paradigm MZ100 (groups MZ06 and MZ12) were used to mill the restorations (n=10). An experimental block (group XR06) was also included only for 0.6 mm-thick occlusal veneers (n=10). The intaglio surfaces were HF-etched and silanated (reinforced ceramics) or airborne-particle abraded and silanated (composite resins). Preparations were airborne-particle abraded and etched before restoration insertion. All restorations were adhesively luted with preheated Filtek Z100. Cyclic isometric chewing was applied at 5 Hz, starting with a load of 200 N (5,000X), followed by stages of 400, 600, 800, 1000, 1200 and 1,400 N at a maximum of 30,000 cycles each. The number of cycles at initial failure (first cracks) was recorded. Samples were loaded until catastrophic failure (lost restoration fragment) or to a maximum of 185,000 cycles. Groups were compared using the Kaplan-Meier survival curves (P=.008 for 0.6 mm-groups and P=0.016 for 1.2 mm-groups, Bonferroni-corrected). The results revealed that: 1) for 0.6 mm-thick occlusal veneers Empress CAD and e.max initially failed at an average load of 500 N and 800 N, respectively and none of them withstood all 185,000 load cycles (survival 0%); with MZ100 and XR the survival rate was 60% and 100%, respectively. 2) for 1.2 mmthick occlusal veneers Empress CAD failed at an average load of 900 N, and none of them withstood all 185,000 load cycles (survival 0%); with e.max CAD and MZ100 survival rate was 30% and 100%, respectively. Both composite resins MZ100 and XR increased the fatigue resistance of ultra-thin occlusal veneers (P<.001) when compared to Empress CAD and e.max. Composite resin MZ100 increased the fatigue resistance of thin occlusal veneers (P<.002) when compared to Empress CAD and e.max CAD.
268

Influência de diferentes métodos de captura de imagem na adaptação marginal e interna de restaurações cerâmicas fabricadas pelo sistema CAD/CAM - CEREC 3D

Delbons, Flávia Barros 25 October 2012 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2010 / Made available in DSpace on 2012-10-25T11:23:44Z (GMT). No. of bitstreams: 1 288466.pdf: 2789575 bytes, checksum: 044dc313f96c9c843b953ef4338b8d08 (MD5) / O objetivo desta pesquisa foi avaliar in vitro a influência de diferentes métodos de captura de imagem na adaptação marginal e interna de restaurações cerâmicas do tipo inlay, fabricadas com o sistema Cerec 3. Para isso, utilizaram-se 10 dentes molares humanos hígidos. Nestes foram realizados preparos MOD. Formaram-se quatro grupos: o IVD, em que foi utilizada a câmera de captura de imagem intraoral Cerec 3 sobre o dente preparado; o IVG, no qual foi utilizada a mesma câmera intraoral, porém a leitura foi realizada sobre o modelo de gesso; o IG, em que a leitura foi feita com o escâner InEos sobre o modelo de gesso; e o LG, no qual a leitura foi realizada com a máquina Cerec Scan sobre o modelo de gesso. Logo, para cada um dos 10 dentes, foram confeccionadas 4 peças cerâmicas. As análises das adaptações marginal e interna foram realizadas antes e após o ajuste interno das restaurações. Para a análise da adaptação marginal, cada peça era colocada sobre o dente, e esse conjunto era levado a um microscópio óptico com aumento de 70 vezes. Para a análise da adaptação interna, utilizou-se a técnica da réplica, na qual foi usado um silicone para simular o cimento resinoso. Após a análise estatística, pôde-se concluir que o ajuste interno das peças é fundamental para que elas apresentem um valor da adaptação marginal clinicamente aceitável e que, quando o escaneamento foi realizado sobre o modelo de gesso, o escâner InEos foi o que apresentou melhor adaptação.
269

Effect of CAD/CAM abutment height and cement type on the retention of zirconia crowns / Efeito da altura do pilar CAD / CAM e tipo de cimento na retenção de coroas de zircônia

Camila Perfeito Evangelista da Silva 07 May 2018 (has links)
Aim: To evaluate the effect of different Ti-base abutment heights and cement type on the pullout retention of zirconia-based restorations. Methods: Identical crowns were designed in a CAD software to fit two different Tibase abutment heights, as follows (n=10/group): (i) 4-mm-height Ti-base abutment (Tall), and (ii) 2.5-mm-height Ti-base abutment (Short). Four cement types were selected: (i) Temporary cement (Provisional); (ii) Glass-ionomer cement (Meron); (iii) self-adhesive resin cement (U200), and (iv) conventional resin cement (Ultimate) with universal adhesive for treatment of titanium and zirconia substrates. Pull-out testing was performed in a universal testing machine. Data were statistically evaluated through two-way analysis of variance following post-hoc comparisons by Tukey test. Results: Tall Ti-base abutments demonstrated similar retention to short abutments when data is collapsed over cement (p>0.74). Data evaluation as a function of cement type demonstrated the superiority of resin-based cements relative to provisional and glass-ionomer groups (p<0.01). Retentiveness data as a function of both factors demonstrated similar force to dislodgment between tall and short abutments for all within cement comparisons (p>0.42), except for U200 (p=0.032). Also, tall abutments cemented with Ultimate evidenced higher pull out values than U200 (p=0.043), and both were significantly more retentive than tall provisional and meron (p<0.001). No significant difference was observed between U200 and Ultimate cements for short abutments (p=0.758), and both presented statistically higher pullout values than provisional and glass-ionomer (p=0.001). Conclusions: While Ti-base abutment height have not influenced zirconia superstructure retentiveness, resin-based cements significantly evidenced higher retention than glass ionomer and temporary cements. / Objetivo: Avaliar o efeito de diferentes alturas de interface de Titânio (Ti) e diferentes tipos de cimento na retenção de coroas de zircônia. Métodos: Coroas idênticas foram projetadas em um software de CAD capaz de adaptar duas alturas diferentes do pilar de interface de Ti: cada grupo foi composto de 10 amostras conforme se segue: (i) interface de Ti de 4 mm de altura (alto) e (ii) interface de 2,5 mm de altura (curto). Foram selecionados quatro tipos de cimento: (i) cimento temporário (Provisional); (ii) Cimento de ionômero de vidro (Meron); (iii) cimento resinoso auto-adesivo (U200) e (iv) cimento resinoso convencional (Ultimate) com adesivo universal para tratamento de substratos de titânio e zircônia. O teste de tração foi realizado em uma máquina de ensaio universal. Os dados foram avaliados estatisticamente através de análise de variância a dois critérios, após comparações pós-hoc pelo teste de Tukey. Resultados: As interfaces de Ti demonstraram retenção semelhante aos pilares curtos quando os dados foram colapsados sobre o cimento (p> 0,74). A avaliação dos dados em função do tipo de cimento demonstrou a superioridade dos cimentos à base de resina em relação aos grupos de cimentos temporário e de ionômero de vidro (p <0,01). Os dados de retenção em função de ambos os fatores demonstraram força semelhante ao deslocamento, entre pilares altos e curtos, para todos dentro das comparações de cimento (p> 0,42), exceto para U200 (p = 0,032). Além disso, os pilares altos cimentados com Ultimate evidenciaram maiores valores de tração do que os cimentados com U200 (p = 0,043), e ambos foram significativamente mais retentivos do que o pilar alto cimentado com cimento Provisional e o Meron (p <0,001). Não foi observada diferença significativa entre os cimentos U200 e Ultimate para pilares curtos (p = 0,758) e ambos apresentaram valores de tração estatisticamente mais elevados que os cimentos de ionômero de vidro e cimento temporário (p = 0,001). Conclusões: Embora a altura da interface de Ti não tenha influenciado a retenção das coroas de zircônia, os cimentos resinosos resultaram em maior retenção do que o ionômero de vidro e cimentos temporários.
270

Proposta metodológica para modelagem geométrica a partir de imagens médicas / Tiago Francesconi ; orientador, Osíris Canciglieri Junior

Francesconi, Tiago January 2008 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2008 / Bibliografia: f. [87]-91 / O grande desenvolvimento tecnológico das últimas décadas trouxe modificações de grande importância em diversas áreas do conhecimento. Na engenharia, pode-se citar como uma destas modificações a alteração da ideologia e construção de projetos mecânicos, re / The great technological development in decades has brought changes of great importance in several areas of knowledge. In engineering, you can cite as one of those modifications to change the ideology and construction of mechanical projects, related to the

Page generated in 0.0173 seconds