• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 4
  • 4
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo retrospectivo da cardioversão elétrica em pacientes com fibrilação atrial e flutter atrial de um hospital universitário

Uehara, Rose Mary January 2006 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, 2006. / Submitted by Priscilla Brito Oliveira (priscilla.b.oliveira@gmail.com) on 2009-11-13T22:39:28Z No. of bitstreams: 1 2006_Rose Mary Uehara.pdf: 1023658 bytes, checksum: 60ff5f1bc986d4c023cba153dd27bbb0 (MD5) / Approved for entry into archive by Luanna Maia(luanna@bce.unb.br) on 2010-02-01T14:57:18Z (GMT) No. of bitstreams: 1 2006_Rose Mary Uehara.pdf: 1023658 bytes, checksum: 60ff5f1bc986d4c023cba153dd27bbb0 (MD5) / Made available in DSpace on 2010-02-01T14:57:18Z (GMT). No. of bitstreams: 1 2006_Rose Mary Uehara.pdf: 1023658 bytes, checksum: 60ff5f1bc986d4c023cba153dd27bbb0 (MD5) Previous issue date: 2006 / Esta é uma pesquisa epidemiológica, analítica, que estudou retrospectivamente os prontuários dos pacientes internados na Unidade Coronariana do Núcleo do Hospital Universitário da Universidade Federal de Mato Grosso do Sul, com diagnósticos de fibrilação atrial (FA) ou flutter atrial (FlA) submetidos à cardioversão elétrica (CVE) externa, de junho de 1999 a dezembro de 2005. Teve como objetivo, caracterizar a amostra, identificar a taxa de sucesso em pacientes com FA e FlA submetidos a CVE externa, avaliar a influência das variáveis estudadas e do posicionamento das pás-eletrodo na taxa de sucesso do procedimento e avaliar a carga cumulativa necessária para o sucesso. Foram avaliados 112 pacientes, sendo 79 com FA e 33 com FlA, com idade variando de 17 a 84 anos e predominância do sexo masculino. Do total de pacientes, 59 foram submetidos à CVE ântero-lateral (AL) e 53 à CVE ântero-posterior (AP). A energia inicial dos choques utilizados na CVE externa dos pacientes com FA foi de 200J e em casos de insucesso 360J. Já nos pacientes com FlA iniciou-se com choques de 100J e em casos de insucesso foram aplicados choques seqüenciais de 200J e 360J, se necessário. Em casos de insucesso na primeira abordagem, foi realizada uma nova tentativa com o croosover das pás-eletrodo de AP para AL ou vice-versa. As variáveis analisadas − índice de massa corpórea (IMC), diâmetro ântero-posterior, circunferência torácica e o diâmetro do átrio esquerdo ao ecocardiograma − não diferiram nos grupos com sucesso e insucesso, não tendo influência significativa na taxa de sucesso da CVE em pacientes com flutter e fibrilação atrial. A taxa global de sucesso da CVE transtorácica foi de 91,07%. Na FA, quando a abordagem foi AL, a taxa de sucesso foi de 75% contra 94,87% na abordagem AP (p=0,03). No FlA, quando a abordagem foi AL, a taxa de sucesso foi de 100%, contra 92,86% quando a abordagem foi AP (p=0,34). Nos pacientes com FA, a taxa de sucesso do choque inicial de 200J foi significativamente maior na abordagem AP (69,2%) que na abordagem AL (42,5%; p=0,03). Nos pacientes com FA houve uma tendência a uma menor carga cumulativa com as pás na posição AP (356,92+244,93J) em relação à posição AL (467,50 + 270,34J; p=0,09). A carga cumulativa utilizada no FlA na posição AL foi de 194,29+221,52J e na AP 220,00+313,88J, não havendo diferença significativa. Conclusão: Em pacientes com FA, a CVE AP foi significativamente superior a CVE AL, mostrando também uma tendência ao uso de menor carga cumulativa. A abordagem mais adequada para a CVE da FA foi a AP, com choque inicial de 200 J. ______________________________________________________________________________________ ABSTRACT / This is an epidemiological, analytical research, that studied retrospectively handbooks of the patients hospitalized in the Unidade Coronariana do Núcleo do Hospital Universitário da Fundação Universidade de Mato Grosso do Sul, with atrial fibrillation (FA) or atrial flutter (FlA) diagnosis who have been submitted to external electrical cardioversion (CVE), from1999-June to 2005-December. Recognize the sample, identify the CVE rate success using different paddle positions during the procedure and the necessary success cumulative load (CC) where the main objectives. Of 112 patients, 79 FA and 33 FlA, with age average of 17 to 84 and masculine sex predominance. 59 of them were submitted to anterior-lateral (AL) paddle position and 53 to the anterior-posterior (AP) position. FA patients, the first synchronized shock used in the external CVE have a 200J shocks and 360J one in unsuccessful cases, and FlA patients, a 100J shock first, and a 200J and 360J sequence shocks when needed. When the first boarding was not sufficient, paddle electrode crossovers were performed, from AP to AL or vice versa. Body mass index (IMC), anterior-posterior chest diameter, chest circumference and echocardiograph left atrium diameter were the analyzed data, with no significant difference in CVE success. The total external CVE success rate was of 91,07%, with 75% when using AL electrode position in FA against 94,87% when using AP electrode position (p=0,03). With AL electrode position, a 100% successfully was seen in FlA, against 92,86% when using AP electrode position (p=0,34). The successfully 200J initial shock in FA patients were significant higher in AP electrode position (69.2%), than in AL (42.5%; p=0,03). FA patients had trends less cumulative load in AP paddle position (356,92+244,93J) than AL position (467,50 + 270,34J; p=0,09). In those patients (FA) the cumulative load (CC) used had no difference significant in both positions. Conclusion: In patients with FA, an external CVE in AP electrode position was significantly more effective than CVE AL electrode position and also showed a trend to use minor CC. So, in this study, the successfully procedure in FA CVE was initial energy of 200J shock in AP paddle position.
2

Comprometimento contratil do tecido cardiaco isolado apos estimulação com campo eletrico de alta intensidade

Soares, Gentil Silveira 03 August 2018 (has links)
Orientador: Jose Wilson Magalhães Bassani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-03T15:12:41Z (GMT). No. of bitstreams: 1 Soares_GentilSilveira_M.pdf: 4340899 bytes, checksum: 87654ba18137f1d9c072dbe8453f8127 (MD5) Previous issue date: 2003 / Resumo: Este trabalho teve como objetivo investigar os efeitos da estimulação de alta intensidade sobre a atividade contrátil do tecido atrial isolado de rato. Procurou-se estabelecer a relação do efeito encontrado com a atividade do retículo sarcoplasmático (RS), utilizando como ferramenta a contração induzida por resfriamento rápido (RCC). Após o choque, a amplitude das contrações reduziu 3±:3 % a 60V/cm, 13±5 % a 130V/cm e 73±13 % a 220V/cm (P<0,001), assim como a amplitude da RCC induzida logo após o choque que apresentou diminuição de ±:4 % a 60V/cm, 64±8 % 130V/cm e 90±:2 % a 220V/cm (P<0,001). Portanto, verificou-se que o campo elétrico de alta intensidade provoca depressão da atividade contrátil e afeta a carga de cálcio do RS, transitoriamente, de modo dependente da amplitude da estimulação. A recaptação de Ca2+ pelo RS não foi, aparentemente, afetada. Um aumento significativo da tensão diastólica pós-choque (P<0,0001) pode ter sido causado por um acúmulo de Ca2+ ocasionado não só por perda temporária de Ca2+ reticular, mas também pela entrada de Ca2+ do meio extracelular através da membrana, visto que tal reação é intensamente reduzida na ausência de Ca2+ externo. Analisando a influência da duração do pulso de alta intensidade na depressão pós-choque constatamos que, embora este fator também contribua para o aumento dos efeitos adversos da estimulação de alta intensidade, o aumento da duração do choque é menos crítico que a elevação da amplitude do mesmo. Os resultados são concordantes com a literatura e tem aplicação direta para o entendimento dos mecanismos de ação envolvidos na depressão da atividade contrátil cardíaca após a desfibrilação e por outros métodos de estimulação com campos de alta intensidade / Abstract: The objective of the present work was to investigate the effect of high intensity electric field stimulation on the contractile activity of the isolated rat atrial tissue. We have used Rapid Cooling Contractures (RCCs) to study the relationship between the effect produced by the electrical shocks and the activity of the sarcoplasmic reticulum (RS). After high intensity shocks, the amplitude of twitch contractions dropped to 3±:3% at 60V/cm, 13±5% at 130V/cm and as much as 73±13% at 220V/cm (P<0,001). In parallel, the amplitude of the RCCs, induced soon after a given shock, presented a reduction of 10±4% at 60V/cm, 64±:8% at 130V/cm and 90±2% at 220V/cm (P<0,001). These results indicate that high intensity electric field stimulation causes depression of the contractile activity and transiently reduces the RS Ca2+ load. The SR Ca2+ uptake was not significantly affected. A significant (P<0,0001) increase of resting (diastolic) tension was found to be attributed to both the intracellular Ca2+ overload, caused by an intense although temporary SR Ca2+ loss, and to Ca2+ influx from the extracellular media, the later markedly reduced by external Ca2+ removal. We also analyzed the combined effects of shock duration and field intensity on the contractile depression. We found that an increased duration may facilitate contractile depression for a given amplitude but duration is less critical than amplitude in producing the adverse effects. The results may be useful to help understand the basic mechanisms involved in cardiac depression after defibrillation and other methods of cardiac stimulation with high intensity electric fields / Mestrado / Engenharia Biomedica / Mestre em Engenharia Elétrica
3

AMDC : analisador microcontrolado de desfibriladores e cardioversores

Pennafiel, Uilson Ruas 12 October 1998 (has links)
Orientação: Sergio Santos Muhlen / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-25T13:55:29Z (GMT). No. of bitstreams: 1 Pennafiel_UilsonRuas_M.pdf: 6494676 bytes, checksum: 09cddfa5838d480e65df632bfd390aaf (MD5) Previous issue date: 1998 / Resumo: O funcionamento eficaz e seguro de equipamentos médicos, tais como desfibriladores e cardioversores, requer manutenção preventiva e corretiva que, em muitos casos, precisa ser realizada próximo à unidade hospitalar onde os equipamentos são utilizados. Este trabalho descreve o desenvolvimento de um analisador microcontrolado de desfibriladores e cardioversores, que atende aos requisitos de versatilidade de um instrumento de calibração, a um custo relativamente baixo. O analisador é portátil e auto-suficiente (pode ser alimentado e carrega automaticamente suas baterias) e mede os seguintes parâmetros do pulso desfibrilatório: 1) energia direta e reversa (em 4 escalas, variando de 2 a 1.000J); 2) amplitude máxima de tensão e corrente das parcelas positiva e negativa (até 6 kV); 3) taxas de subida tR, t50 e t10 da norma ANSI/AAMI-DF2 (de 100ms até 200 ms); e 4) duração (de 100ms até 200 ms). A forma de onda do pulso desfibrilatório é apresentada num display tipo LCD de 256x64 pixels e todos os parâmetros aferidos podem ser impressos ou transmitidos a um dispositivo de registro. Uma carga resistiva de entrada (de 25, 50, 75, 100 ou 125 O), selecionada pelo usuário operador, simula a impedância transtorácica do corpo humano. Para testar cardioversores, o analisador simula o complexo QRS ou aguarda um sinal de sincronismo externo para medir o tempo de resposta (atraso entre o sinal de sincronismo e a cardioversão). Ensaios em laboratório com instrumentos calibrados (osciloscópio e geradores) e com destibriladores / cardioversores demonstraram um bom desempenho do protótipo / Abstract: The effectiveness and safety of medical devices, such as defibrillators and cardioverters, require preventive maintenance and repair, which should be carried out in many instances near the hospital unit where the devices are being used. This work describes the development of a microcontrolled analyzer, which fulfills the requirements of a calibrating equipment, at a relatively low cost. The analyzer is powered by batteries, is self-sufficient and measures the following defibrillator output pulse parameters: 1) direct and reverse energy (four ranges, from 2 to 1,000J); 2) direct and reverse peak voltage and current (up to 6 kV); 3) ANSI/AAMI-DF2 tR, t50 and t10 rise rate (from 100ms to 200 ms); and 4) pulse width (from 100ms to 200ms). The defibrillating pulse waveform is shown on a 256x64-pixel LCD display. All measured parameters can be printed or transmitted to a record device. An internal resistive load (of 25, 50, 75, 100 or 125 O) simulates the transthoracic impedance of the human body. To test cardioverters, the analyzer simulates the QRS complex and measures the response time (delay between synchronous and cardioverter pulses). Laboratory tests performed with calibrated instruments (oscilloscope and generators) and field tests with different types of defibrillators have shown good performance of the prototype / Mestrado / Automação / Mestre em Engenharia Elétrica
4

Limiar de comando ventricular de marcapasso cardíaco após choque transtorácico utilizando diferentes formatos de onda : um estudo experimental / Ventricular pacing threshold of cardiac pacemaker after transthoracic external shock with different waveforms : an experimental study

Assumpção, Antonio Carlos, 1960- 12 December 2013 (has links)
Orientador: Orlando Petrucci Junior / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-24T07:48:01Z (GMT). No. of bitstreams: 1 Assumpcao_AntonioCarlos_D.pdf: 13951044 bytes, checksum: 4ebd9040bcd7ea540e6927bdc4258384 (MD5) Previous issue date: 2013 / Resumo: Introdução: O aumento do limiar de estimulação ventricular (LEV) tem sido observado após a administração de choque elétrico de cardioversão/desfibrilação transtorácico (CDT) para desfibrilação ventricular, contudo, poucos estudos têm avaliado este fenômeno no que diz respeito à energia e a forma de onda empregada para a CDT. Este estudo analisou o LEV após CDT de 360J, comparando-se os resultados após aplicação de onda de energia Mono e Bi. Método: Em suínos Landrace femininos foram implantados sistema de estimulação permanente de marcapasso, divididos em três grupos: sem indução de fibrilação ventricular (FV) e CDT com formato de onda monofásica (Mono) e bifásica (Bi) (Grupo I); indução FV, um minuto de observação sem intervenção, dois minutos de massagem cardíaca externa, e CDT Mono e Bi (Grupo II) e indução de FV, dois minutos de observação sem intervenção, quatro minutos de massagem cardíaca externa e CDT Mono e Bi (Grupo III). Após CDT, o LEV foi avaliado a cada minuto durante dez minutos. Resultados: Um total de 143 experimentos foram concluídos. No final do período de observação, os grupos I e II mostraram valores constantes LEV. O Grupo III mostrou aumento no LEV Mono e Bi com energia externa, sem diferença entre os formatos de ondas externas. O formato Mono foi associada a valores mais elevados de LEV quando o tempo de parada cardiorrespiratória (PCR) foi maior, o que não foi verificado na Bi. Conclusão: A CDT não tem impacto significativo sobre o LEV. Com onda Mono, observou-se aumento do LEV quando o período de PCR foi mais longo / Abstract: Introduction. Although an increase in the ventricular pacing threshold (VPT) has been observed after administration of transthoracic shock for ventricular defibrillation, few studies have evaluated the phenomenon in respect to the defibrillation waveform energy. Therefore, this study examined the VPT behavior after transthoracic shock with a monophasic or biphasic energy waveform. Method. Domestic Landrace female piglets implanted with a permanent pacemaker stimulation system were divided into 3 groups: no ventricular fibrillation (VF) induction and transthoracic shock with monophasic or biphasic energy (group I); VF induction, 1 minute of observation without intervention, 2 minutes of external cardiac massage, and transthoracic shock with monophasic or biphasic energy (group II); and VF induction, 2 minutes of observation without intervention, 4 minutes of external cardiac massage, and transthoracic shock with monophasic or biphasic energy (group III). After external shock, the VPT was evaluated every minute for 10 minutes. Results. A total of 143 experiments were performed. At the end of the observation period, groups I and II showed steady VPT values. Group III showed an increase in VPT with monophasic or biphasic external energy, with no difference between the external energy sources. The monophasic but not the biphasic waveform was associated with higher VPT values when the VF was longer. Conclusion. Defibrillation does not have a significant impact on pacing threshold, but a longer VF period is related to a higher VPT after defibrillation with monophasic waveform / Doutorado / Fisiopatologia Cirúrgica / Doutor em Ciências

Page generated in 0.0886 seconds