Système modulaire de traitement pour la tomographie d'émission à partir de détecteurs CdZnTe / Modular processing system for emission tomography with CdZnTe détector

Bernard, Mélanie 06 November 2017 (has links)
Depuis plusieurs années, une nouvelle technologie de détecteurs à partir de matériaux semi-conducteurs CdTe/CdZnTe permet de proposer des appareils d’imagerie médicale bénéficiant de meilleures performances, notamment en imagerie gamma. Ces performances sont obtenues en combinant simultanément les technologies des détecteurs, leur géométrie, les algorithmes de reconstruction et les architectures de traitement des données. Des travaux ont précédemment montré que des améliorations étaient possibles en revoyant la collimation du système. En plus des bonnes performances intrinsèques des détecteurs à semi-conducteur, leur intérêt réside dans leur compacité, permettant de proposer des géométries plus flexibles. De nouvelles architectures ont alors vu le jour, notamment en imagerie cardiaque.Afin d’aller au-delà du compromis entre résolution spatiale, sensibilité et champ de vue imposé par la surface de détection disponible, cette thèse propose d’étudier les possibilités d’adaptation offertes par ces nouvelles architectures. Une adaptation de l’échantillonnage angulaire des têtes de détection indépendamment les unes des autres est envisagée, permettant des protocoles d’acquisition plus adaptés à la diversité des examens et des morphologies.Depuis plusieurs années, une nouvelle technologie de détecteurs à partir de matériaux semi-conducteurs CdTe/CdZnTe permet de proposer des appareils d’imagerie médicale bénéficiant de meilleures performances, notamment en imagerie SPECT. Ces performances sont obtenues en travaillant simultanément sur la localisation précise des mesures dans les détecteurs, la collimation, l’adéquation entre la géométrie des systèmes d’acquisition et les spécificités de l’examen, les algorithmes de reconstruction et les architectures de traitement des données. En plus des bonnes performances intrinsèques des détecteurs à semi-conducteur, leur intérêt réside dans leur compacité accrue par rapport aux scintillateurs et leurs photomultiplicateurs, permettant de proposer des géométries plus flexibles. De nouvelles architectures ont alors vu le jour, notamment en imagerie cardiaque.L’imagerie SPECT est contrainte par un compromis entre résolution spatiale, sensibilité et champ de vue imposé par le collimateur, et la surface de détection disponible. Afin d’aller au-delà de ce compromis, cette thèse propose d’étudier les possibilités d’adaptation en ligne offertes par ces nouvelles architectures flexibles. Un système inspiré d’un dispositif industriel déjà proposés, composé de plusieurs têtes de détection indépendantes est étudié. Une adaptation de l’échantillonnage angulaire des têtes de détection indépendamment les unes des autres est envisagée, permettant des protocoles d’acquisition plus adaptés à la diversité des examens et des morphologies.L’objectif de cette thèse est de mettre en place un processus d’acquisition / adaptation permettant de reconfigurer le parcours des têtes en fonction d’une estimation de l’objet à imager. Des solutions algorithmiques sont proposées afin d’implémenter la reconstruction en temps réel du volume à imager à partir de données rendues plus complexes par les degrés de liberté du système et par la précision du détecteur. La reconstruction obtenue en temps réel doit permettre de déterminer les zones du volume à imager les plus porteuses d’information afin d’y orienter les têtes. La simulation permet dans un premier temps l’étude théorique du concept de système modulaire, ainsi que la mise en place algorithmique du processus de reconstruction rapide, permettant une estimation exploitable de l’objet lors de l’acquisition. Quelques résultats expérimentaux permettront de valider la modélisation du système, ainsi que l’algorithme de reconstruction. Enfin, l’étude de différentes stratégies d’adaptation sera amorcée par simulation. / In the last decades, new CdTe/CdZnTe based detectors enable enhanced performances on medical imaging systems, especially in SPECT imaging. This improvements are achieved by developing simultaneously the precise localization of interaction in detectors, the collimator, matching between the system geometry and the specificities of the examination, reconstruction algorithms, and data processing architectures. In addition to their interesting intrinsic performances, CdZnTe detectors benefits from their compactness compared to previously used scintillators and photo-multiplicators. This compactness enables more flexible systems. New designs are thus proposed, especially in cardiac imaging.Performances of SPECT systems are limited by a trade-off between the spatial resolution, the sensitivity and the field of view imposed by the collimator and the available detection surface. In order to go further this compromise, this work focuses on possibilities for online adaptation offered by flexibles designs. Adaptation on a system composed of several independent detection heads already proposed by industrials is under study. We propose to adapt the angular sampling of heads, enabling acquisition protocols more accurate for different patient morphologies and examination protocols.The purpose of this work is to propose acquisition and adaptation protocols enabling the reconfiguration of the angular sampling of detection heads depending on an estimation of the imaged object. Algorithmic solutions are proposed in order to compute the reconstruction in real time from more complex data because of additional degrees of freedom and detector precision. The resulting estimation have to enable the identification of informative areas in order to focus detection heads on it. Simulations approves theoretically the use of our rapid algorithmic solution on a modular system carrying a reliable estimation of the object. Some experimental results validate the system model and the reconstruction algorithm. Then, some adaptation strategies are investigated using simulations.
2

Detektory RTG a gama záření na bázi polovodiče CdTe/CdZnTe / Gamma and X- ray CdTe/CdZnTe detectors

Pekárek, Jakub January 2013 (has links)
In the present work we studied an influence of different types of surface etching and surface passivation of high resistivity CdZnTe-based semiconductor detector material. The aim was to find the optimal conditions to improve the properties of metal-semiconductor contact. The main effort was to reduce the leakage current and thus get better X-ray and gamma-ray spectrum, ie to create a detector operating at room temperature based on this semiconductor material with sufficient energy resolution and the maximum charge collection efficiency. Individual surface treatments were characterized by volt-ampere characteristics, spectral analysis and by determination of the profile of the internal electric field.
3

Investigations on CdZnTe-Semiconductor-Detectors for the Search of the Neutrinoless Double Beta Decay

Gehre, Daniel 11 September 2018 (has links)
The Cadmium-Zinc-Telluride 0-Neutrino-Double-Beta Research Apparatus (COBRA-Experiment) investigates the theoretically predicted neutrinoless double beta decay (0νββ-decay) to indirectly determine the effective Ma- jorana mass of the electron-neutrino by a measurement of the half-life of the 0νββ-decay using room-temperature semiconducting Cadmium-Zinc- Telluride-detectors (CZT). The detectors are made of elements containing several isotopes that decay via double beta decay (ββ-decay). In such a con- figuration the detector itself becomes the source of the decay and, hence, the efficiency for the detection of such events rises. This work covers the investigations and characterizations made on the CZT detectors used in the COBRA-Experiment, currently running. Prior to in- stallation the physical properties of the detectors are analyzed and during operation the stability of the detectors is monitored. For the laboratory analysis three dedicated setups are developed that allow for detailed inves- tigations of different properties of the detectors. Beside the working point determination and the analysis of the temperature dependence of the de- tector performance, the spatial detector response to localized irradiation is analyzed and a setup to generate a library of specific pulse shapes is designed and operated. Furthermore, an investigation for a possible discrimination of α- and β-decay events based on pulse shape discrimination is performed as well as an analysis of the long term stability of underground operated CZT detectors.
4

Instrumentation of CdZnTe detectors for measuring prompt gamma-rays emitted during particle therapy / Instrumentierung von CdZnTe Detektoren zur Messung prompter Gammastrahlung während der Teilchentherapie

Födisch, Philipp 15 May 2017 (has links) (PDF)
Background: The irradiation of cancer patients with charged particles, mainly protons and carbon ions, has become an established method for the treatment of specific types of tumors. In comparison with the use of X-rays or gamma-rays, particle therapy has the advantage that the dose distribution in the patient can be precisely controlled. Tissue or organs lying near the tumor will be spared. A verification of the treatment plan with the actual dose deposition by means of a measurement can be done through range assessment of the particle beam. For this purpose, prompt gamma-rays are detected, which are emitted by the affected target volume during irradiation. Motivation: The detection of prompt gamma-rays is a task related to radiation detection and measurement. Nuclear applications in medicine can be found in particular for in vivo diagnosis. In that respect the spatially resolved measurement of gamma-rays is an essential technique for nuclear imaging, however, technical requirements of radiation measurement during particle therapy are much more challenging than those of classical applications. For this purpose, appropriate instruments beyond the state-of-the-art need to be developed and tested for detecting prompt gamma-rays. Hence the success of a method for range assessment of particle beams is largely determined by the implementation of electronics. In practice, this means that a suitable detector material with adapted readout electronics, signal and information processing, and data interface must be utilized to solve the challenges. Thus, the parameters of the system (e.g. segmentation, time or energy resolution) can be optimized depending on the method (e.g. slit camera, time-of-flight measurement or Compton camera). Regardless of the method, the detector system must have a high count rate capability and a large measuring range (>7 MeV). For a subsequent evaluation of a suitable method for imaging, the mentioned parameters may not be restricted by the electronics. Digital signal processing is predestined for multipurpose tasks, and, in terms of the demands made, the performance of such an implementation has to be determined. Materials and methods: In this study, the instrumentation of a detector system for prompt gamma-rays emitted during particle therapy is limited to the use of a cadmium zinc telluride (CdZnTe, CZT) semiconductor detector. The detector crystal is divided into an 8x8 pixel array by segmented electrodes. Analog and digital signal processing are exemplarily tested with this type of detector and aims for application of a Compton camera to range assessment. The electronics are implemented with commercial off-the-shelf (COTS) components. If applicable, functional units of the detector system were digitalized and implemented in a field-programmable gate array (FPGA). An efficient implementation of the algorithms in terms of timing and logic utilization is fundamental to the design of digital circuits. The measurement system is characterized with radioactive sources to determine the measurement dynamic range and resolution. Finally, the performance is examined in terms of the requirements of particle therapy with experiments at particle accelerators. Results: A detector system based on a CZT pixel detector has been developed and tested. Although the use of an application-specific integrated circuit is convenient, this approach was rejected because there was no circuit available which met the requirements. Instead, a multichannel, compact, and low-noise analog amplifier circuit with COTS components has been implemented. Finally, the 65 information channels of a detector are digitized, processed and visualized. An advanced digital signal processing transforms the traditional approaches of nuclear electronics in algorithms and digital filter structures for an FPGA. With regard to the characteristic signals (e.g. varying rise times, depth-dependent energy measurement) of a CZT pixel detector, it could be shown that digital pulse processing results in a very good energy resolution (~2% FWHM at 511 keV), as well as permits a time measurement in the range of some tens of nanoseconds. Furthermore, the experimental results have shown that the dynamic range of the detector system could be significantly improved compared to the existing prototype of the Compton camera (~10 keV..7 MeV). Even count rates of ~100 kcps in a high-energy beam could be ultimately processed with the CZT pixel detector. But this is merely a limit of the detector due to its volume, and not related to electronics. In addition, the versatility of digital signal processing has been demonstrated with other detector materials (e.g. CeBr3). With foresight on high data throughput in a distributed data acquisition from multiple detectors, a Gigabit Ethernet link has been implemented as data interface. Conclusions: To fully exploit the capabilities of a CZT pixel detector, a digital signal processing is absolutely necessary. A decisive advantage of the digital approach is the ease of use in a multichannel system. Thus with digitalization, a necessary step has been done to master the complexity of a Compton camera. Furthermore, the benchmark of technology shows that a CZT pixel detector withstands the requirements of measuring prompt gamma-rays during particle therapy. The previously used orthogonal strip detector must be replaced by the pixel detector in favor of increased efficiency and improved energy resolution. With the integration of the developed digital detector system into a Compton camera, it must be ultimately proven whether this method is applicable for range assessment in particle therapy. Even if another method is more convenient in a clinical environment due to practical considerations, the detector system of that method may benefit from the shown instrumentation of a digital signal processing system for nuclear applications. / Hintergrund: Die Bestrahlung von Krebspatienten mit geladenen Teilchen, vor allem Protonen oder Kohlenstoffionen, ist mittlerweile eine etablierte Methode zur Behandlung von speziellen Tumorarten. Im Vergleich mit der Anwendung von Röntgen- oder Gammastrahlen hat die Teilchentherapie den Vorteil, dass die Dosisverteilung im Patienten präziser gesteuert werden kann. Dadurch werden um den Tumor liegendes Gewebe oder Organe geschont. Die messtechnische Verifikation des Bestrahlungsplans mit der tatsächlichen Dosisdeposition kann über eine Reichweitenkontrolle des Teilchenstrahls erfolgen. Für diesen Zweck werden prompte Gammastrahlen detektiert, die während der Bestrahlung vom getroffenen Zielvolumen emittiert werden. Fragestellung: Die Detektion von prompten Gammastrahlen ist eine Aufgabenstellung der Strahlenmesstechnik. Strahlenanwendungen in der Medizintechnik finden sich insbesondere in der in-vivo Diagnostik. Dabei ist die räumlich aufgelöste Messung von Gammastrahlen bereits zentraler Bestandteil der nuklearmedizinischen Bildgebung, jedoch sind die technischen Anforderungen der Strahlendetektion während der Teilchentherapie im Vergleich mit klassischen Anwendungen weitaus anspruchsvoller. Über den Stand der Technik hinaus müssen für diesen Zweck geeignete Instrumente zur Erfassung der prompten Gammastrahlen entwickelt und erprobt werden. Die elektrotechnische Realisierung bestimmt maßgeblich den Erfolg eines Verfahrens zur Reichweitenkontrolle von Teilchenstrahlen. Konkret bedeutet dies, dass ein geeignetes Detektormaterial mit angepasster Ausleseelektronik, Signal- und Informationsverarbeitung sowie Datenschnittstelle zur Problemlösung eingesetzt werden muss. Damit können die Parameter des Systems (z. B. Segmentierung, Zeit- oder Energieauflösung) in Abhängigkeit der Methode (z.B. Schlitzkamera, Flugzeitmessung oder Compton-Kamera) optimiert werden. Unabhängig vom Verfahren muss das Detektorsystem eine hohe Ratenfestigkeit und einen großen Messbereich (>7 MeV) besitzen. Für die anschließende Evaluierung eines geeigneten Verfahrens zur Bildgebung dürfen die genannten Parameter durch die Elektronik nicht eingeschränkt werden. Eine digitale Signalverarbeitung ist für universelle Aufgaben prädestiniert und die Leistungsfähigkeit einer solchen Implementierung soll hinsichtlich der gestellten Anforderungen bestimmt werden. Material und Methode: Die Instrumentierung eines Detektorsystems für prompte Gammastrahlen beschränkt sich in dieser Arbeit auf die Anwendung eines Cadmiumzinktellurid (CdZnTe, CZT) Halbleiterdetektors. Der Detektorkristall ist durch segmentierte Elektroden in ein 8x8 Pixelarray geteilt. Die analoge und digitale Signalverarbeitung wird beispielhaft mit diesem Detektortyp erprobt und zielt auf die Anwendung zur Reichweitenkontrolle mit einer Compton-Kamera. Die Elektronik wird mit seriengefertigten integrierten Schaltkreisen umgesetzt. Soweit möglich, werden die Funktionseinheiten des Detektorsystems digitalisiert und in einem field-programmable gate array (FPGA) implementiert. Eine effiziente Umsetzung der Algorithmen in Bezug auf Zeitverhalten und Logikverbrauch ist grundlegend für den Entwurf der digitalen Schaltungen. Das Messsystem wird mit radioaktiven Prüfstrahlern hinsichtlich Messbereichsdynamik und Auflösung charakterisiert. Schließlich wird die Leistungsfähigkeit hinsichtlich der Anforderungen der Teilchentherapie mit Experimenten am Teilchenbeschleuniger untersucht. Ergebnisse: Es wurde ein Detektorsystem auf Basis von CZT Pixeldetektoren entwickelt und erprobt. Obwohl der Einsatz einer anwendungsspezifischen integrierten Schaltung zweckmäßig wäre, wurde dieser Ansatz zurückgewiesen, da kein verfügbarer Schaltkreis die Anforderungen erfüllte. Stattdessen wurde eine vielkanalige, kompakte und rauscharme analoge Verstärkerschaltung mit seriengefertigten integrierten Schaltkreisen aufgebaut. Letztendlich werden die 65 Informationskanäle eines Detektors digitalisiert, verarbeitet und visualisiert. Eine fortschrittliche digitale Signalverarbeitung überführt die traditionellen Ansätze der Nuklearelektronik in Algorithmen und digitale Filterstrukturen für einen FPGA. Es konnte gezeigt werden, dass die digitale Pulsverarbeitung in Bezug auf die charakteristischen Signale (u.a. variierende Anstiegszeiten, tiefenabhängige Energiemessung) eines CZT Pixeldetektors eine sehr gute Energieauflösung (~2% FWHM at 511 keV) sowie eine Zeitmessung im Bereich von einigen 10 ns ermöglicht. Weiterhin haben die experimentellen Ergebnisse gezeigt, dass der Dynamikbereich des Detektorsystems im Vergleich zum bestehenden Prototyp der Compton-Kamera deutlich verbessert werden konnte (~10 keV..7 MeV). Nach allem konnten auch Zählraten von >100 kcps in einem hochenergetischen Strahl mit dem CZT Pixeldetektor verarbeitet werden. Dies stellt aber lediglich eine Begrenzung des Detektors aufgrund seines Volumens, nicht jedoch der Elektronik, dar. Zudem wurde die Vielseitigkeit der digitalen Signalverarbeitung auch mit anderen Detektormaterialen (u.a. CeBr3) demonstriert. Mit Voraussicht auf einen hohen Datendurchsatz in einer verteilten Datenerfassung von mehreren Detektoren, wurde als Datenschnittstelle eine Gigabit Ethernet Verbindung implementiert. Schlussfolgerung: Um die Leistungsfähigkeit eines CZT Pixeldetektors vollständig auszunutzen, ist eine digitale Signalverarbeitung zwingend notwendig. Ein entscheidender Vorteil des digitalen Ansatzes ist die einfache Handhabbarkeit in einem vielkanaligen System. Mit der Digitalisierung wurde ein notwendiger Schritt getan, um die Komplexität einer Compton-Kamera beherrschbar zu machen. Weiterhin zeigt die Technologiebewertung, dass ein CZT Pixeldetektor den Anforderungen der Teilchentherapie für die Messung prompter Gammastrahlen stand hält. Der bisher eingesetzte Streifendetektor muss zugunsten einer gesteigerten Effizienz und verbesserter Energieauflösung durch den Pixeldetektor ersetzt werden. Mit der Integration des entwickelten digitalen Detektorsystems in eine Compton-Kamera muss abschließend geprüft werden, ob dieses Verfahren für die Reichweitenkontrolle in der Teilchentherapie anwendbar ist. Auch wenn sich herausstellt, dass ein anderes Verfahren unter klinischen Bedingungen praktikabler ist, so kann auch dieses Detektorsystem von der gezeigten Instrumentierung eines digitalen Signalverarbeitungssystems profitieren.
5

Characterization and optimization of CdZnTe Frisch collar gamma-ray spectrometers and their development in an array of detectors

Kargar, Alireza January 1900 (has links)
Doctor of Philosophy / Department of Mechanical and Nuclear Engineering / Douglas S. McGregor / Cadmium Zinc Telluride (CdZnTe) has been used for many applications, such as medical imaging and astrophysics, since its first demonstration as a room temperature operating gamma-ray detector in 1992. The wide band gap, high effective Z-number and high resistivity of CdZnTe make it a good candidate for use as a room temperature operated detector with good absorption efficiency, while maintaining a low bulk leakage current at high electric fields. Nevertheless, the low mobility lifetime products mu tau of holes in CdZnTe makes detectors position sensitive, unless advanced detector designs are employed. Among those designs is the Frisch collar technology which turns the detector into a single carrier device by negating the degrading effects of hole trapping and low mobility. The superiority of the Frisch collar technology over other methods include its inexpensive associated electronics and straight forward fabrication process. The main objective of this research study is to develop a large volume gamma-ray detector with an array of individual CdZnTe Frisch collar gamma-ray spectrometers while still using a single readout. Several goals were to be accomplished prior to the main objective. One goal is to develop a reliable low cost method to fabricate bulk CdZnTe crystals into Frisch collar detectors. Another goal was to investigate the limitations of crystal geometry and the crystal electrical properties to obtain the best spectroscopic performance from CdZnTe Frisch collar detectors. Still another goal was to study all other external parameters such as the collar length, anode to cathode ratio, the insulator thickness and applied voltage on performance of CdZnTe Frisch collar detectors. The final goal was to construct the CdZnTe Frisch collar devices into an array and to show its feasibility of being used for large volume detector.
6

Modélisation de détecteurs à base de semiconducteurs pour la spectroscopie et l'imagerie des rayons-[y] ?

Benoit, Mathieu January 2008 (has links)
Mémoire numérisé par la Division de la gestion de documents et des archives de l'Université de Montréal.
7

Bulk Growth And Characterization Of Cadmium Zinc Telluride Crystals For Mercury Cadmium Telluride Infrared Detector Applications

Ergunt, Hasan Yasin 01 September 2012 (has links) (PDF)
HgCdTe (MCT) infrared (IR) photodetectors have been used for various military and civilian applications including thermal imaging, medical imaging, and astronomy. These detectors are commonly fabricated on MCT layers grown on a foreign substrate epitaxially using delicate growth techniques such as Molecular Beam Epitaxy (MBE). The crystal quality of epitaxial layers grown on a substrate critically depends on the quality of the substrate. One of the stringent requirements in choosing the substrate material is the lattice match between grown layer and the underlying substrate. With perfectly matching lattice structure, CdZnTe has been the major substrate material for the MCT growth. The production of defect free single crystal CdZnTe bulk crystal has then attracted great attention among the research and industrial community of MCT based photodetectors. This thesis focuses on the growth and characterization of Cd1-xZnxTe crystals with the main objective of obtaining high-quality, CZT bulk crystal with large crystal sizes. To be compatible with the subsequent MCT growth, we aimed to obtain Cd0.96Zn0.04Te crystals with (211) crystal surface orientation. CdZnTe bulk crystal growths were performed in three-zone vertical Bridgman furnace by a high temperature melt process called &ldquo / Modified Bridgman Technique&rdquo / . Difficulties in both growth and characterization are presented and discussed in this report. Characterization of the grown CdZnTe crystal was performed to determine the crystallographic orientation, crystal quality, Zn distribution, IR transmission, resistivity, polarity, etch pit density, and surface properties. For this purpose, electron microscopy with analytical diagnostic tools like EDS and EBSD, XRD, optical transmission spectroscopy, and electrical measurement systems have been employed. We demonstrated the successful growth of single crystal CZT crystals using our simple Bridgman furnace. Physical properties of the grown crystal were very promising and encouraging for future applications. Crystal pieces having sizes larger than 5 x 5 mm2 with uniform Zn distribution and (211) surface orientation were obtained. IR transmission of nearly 60% which is as good as that of the commercial substrates was achieved. The electrical resistivity was much better (higher) than generally accepted values. However, the XRD results indicated the presence of defects and/or micro grains in the bulk crystal. These structures seemed to have prevented obtaining good FWHM values, which are the measure of crystal quality, in the XRD analysis.
8

Modélisation de détecteurs à base de semiconducteurs pour la spectroscopie et l'imagerie des rayons-[y] ?

Benoit, Mathieu January 2008 (has links)
Mémoire numérisé par la Division de la gestion de documents et des archives de l'Université de Montréal
9

The feasibility of liquid phase electroepitaxial growth of cadmium zinc telluride.

Armour, Neil Alexander 18 November 2008 (has links)
No description available.
10

The feasibility of liquid phase electroepitaxial growth of cadmium zinc telluride.

Armour, Neil Alexander 18 November 2008 (has links)
No description available.