• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 74
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 77
  • 77
  • 38
  • 34
  • 32
  • 20
  • 20
  • 14
  • 14
  • 13
  • 12
  • 11
  • 10
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Resistência à flexão de barras cerâmicas seccionadas de diferentes formas e posteriormente unidas e infiltradas por vidro fundido

Miyashita, Eduardo [UNESP] 13 June 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-06-13Bitstream added on 2014-06-13T21:07:02Z : No. of bitstreams: 1 miyashita_e_dr_sjc.pdf: 3137617 bytes, checksum: 1740fa8d2b92339817be4c31e59b1ef9 (MD5) / O objetivo deste trabalho foi avaliar a resistência à flexão de barras de In-Ceram Alumina e In-Ceram Zircônia sinterizadas, seccionadas de diferentes formas e posteriormente unidas e infiltradas por vidro fundido. Foram confeccionados duzentos corpos-de-prova, sendo cem do Grupo A (In-Ceram Alumina / ICA) - e cem do Grupo Z (In-Ceram Zircônia / ICZ). Todas as amostras foram confeccionadas segundo as recomendações do fabricante, com as dimensões de 25,0mm X 4,0mm X 3,0mm, e sinterizadas em um forno especial Inceramat III (Vita). As amostras foram dividas em cinco subgrupos: a) controle; b) corte reto central; c) corte diagonal 45º na região central; d) corte central com revestimento total; e) corte diagonal 45º na região de apoio. As amostras seccionadas foram unidas com o próprio material cerâmico, em dispositivo que manteve o alinhamento entre os segmentos cerâmicos, e novamente levadas ao forno, realizando novo ciclo de sinterização. Os corpos-de-prova foram submetidos ao ensaio de flexão de três pontos usando uma máquina de ensaios universal EMIC. Os resultados foram submetidos à análise de variância one-way e ao teste de Tukey (5%). Os resultados indicaram não haver diferença significativa entre os grupos controle dos materiais ICA controle (425,60l73,81MPa); ICZ controle (469,11l66,62MPa) e as amostras do subgrupo (GZ4) ICZ com corte diagonal 45º na região de apoio (416,39l54,64MPa) não apresentaram diferenças estatísticas significantes. A microscopia eletrônica de varredura para avaliação morfológica na região da fratura não apresentou diferenças marcantes entre os grupos analisados. Entretanto, foram observadas um maior número de lacunas entre o material cerâmico de união e a estrutura cerâmica, principalmente no subgrupo 3 - com corte na região central e recobrimento total. / The aim of this work was to evaluate the flexural resistance of In-Ceram Alumina (ICA) and In-Ceram Zirconia (ICZ) bars, sinterized, cut in different shapes and afterwards jointed and infiltrated by glass. Two hundred samples were manufactured, being 100 of the group A (In-Ceram Alumina) and 100 of group Z (In-Ceram Zirconia). All the samples were made according to the manufacturer recommendations with the dimensions of 25,0mm X 4,0mm X 3,0mm, and fired in a special furnace (Inceramat III, Vita). The samples were divided in 5 sub-groups: a) control; b) central straight cut; c) diagonal cut 45º in the central region; d) central cut with total covering; e) diagonal cut 45º in the support region. The separated samples were then jointed with the same ceramic material in a device that kept the alignment between the segments and these were fired in a new e of sintering cycle. The samples were subjected to the three point bending test using a universal test machine EMIC. The results were submitted to the analysis of variance one-way and to the Tukey test (5%). There were no statistically significant differences (p<0,05) between the control groups: ICA control (425,60l73,81MPa); ICZ control (469,11l66,62MPa) and no statistically significant difference for the samples of sub-group (GZ4) ICZ diagonal cut 45º in the support region (416,39l54,64MPa). The electronic scanning microscopy showed no differences the morphology of the region of the crack in the analyzed groups. However, major gaps were observed between the ceramic union material and the ceramic structure, mainly in sub-group 3 - central cut with total covering.
52

Estudo da fadiga flexural de porcelana feldspática: efeito da ciclagem mecânica e limite de resistência pelo método de escada

Schalch, Max von [UNESP] 08 March 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-03-08Bitstream added on 2014-06-13T19:05:03Z : No. of bitstreams: 1 schalch_m_dr_arafo.pdf: 538787 bytes, checksum: 4ca8b6178fc03b9c476272eb4ecb7907 (MD5) / O objetivo deste estudo foi avaliar a fadiga flexural da porcelana feldspática Duceragold (Degudent, processada por sinterização), utilizando a ciclagem mecânica e o método de escada. Foram confeccionados setenta corpos-de-prova, em forma de barra (25mm de comprimento, 5mm de largura, 2mm de espessura - ISO 6872, 1997). Os resultados mostraram resistência à flexão de 93,19MPa e limite de resistência à fadiga de 29,65MPa (redução da resistência de 68,19%). Não houve diferença estatística para a resistência à flexão após ciclagem mecânica entre G1 (87,53MPa), G2 (95,32MPa) e G3 (97,30MPa). Nestas três situações, a ciclagem mecânica empregada não foi capaz de reduzir a resistência à flexão da porcelana feldspática. Embora não tenha havido redução de resistência nos grupos ciclados mecanicamente, a avaliação fractográfica evidenciou a presença de estrias, sinais característicos de fadiga. / The aim of this study was to evaluate the flexural fatigue of a feldsphatic dental porcelain Duceragold (Degudent, convencional fusing), using cyclic loading and staircase method. Seventy specimens were made (25mm length; 5mm width; 2mm thick - ISO 6872). The flexural strength without prior cyclic loading was 93,19MPa and the limit fatigue was 29,65MPa (68,19% reduced strength). Analysis of the flexural strength with prior cyclic loading indicated no significant differences among G1 (87,53MPa), G2 (95,32MPa) and G3 (97,30MPa). On these groups, the cyclic loading did not reduce the flexural strength of a feldsphatic porcelain. Despite no reduce on strength was observed for cyclic loading groups, the fractography showed fatigue signals (striations).
53

Adesão e grau de conversão: efeito das cores da cerâmica e do agente de fixação resinoso

Passos, Sheila Pestana [UNESP] 18 October 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-10-18Bitstream added on 2014-06-13T20:45:49Z : No. of bitstreams: 1 passos_sp_dr_sjc.pdf: 3848792 bytes, checksum: 3fb1f1393e2dc87d50d66555ecfbb5ae (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste trabalho foi avaliar a translucidez de diferentes cores da cerâmica, o grau de conversão de diferentes cores do agente de fixação resinoso e a resistência de união entre a cerâmica e a dentina, variando as cores da cerâmica e do agente de fixação e o tempo de fotoativação. A hipótese é que quanto mais escuros o agente de fixação resinoso e a cerâmica, menor translucidez, menor conversão dos monômeros, mais baixa será a resistência adesiva, portanto maior tempo necessário para fotoativação. Três discos da cerâmica Vita VM7 com dimensão de 20 x 2 mm nas cores Base Dentine 0M1, Base Dentine 2M2 e Base Dentine 5M3 e dois discos com 20 x 2,5 mm da mesma cerâmica nas cores Base Dentine 0M1 e Base Dentine 5M3 foram usados para determinar a percentagem de translucidez através do espectrofotômetro MiniScan. Para se obter o grau de conversão (GC), os cp do agente de fixação (Variolink II; A3 Amarelo e transparente; espessura: 100 μm) foram fotoativados sob um bloco cerâmico (espessura: 2 mm; Base Dentine 0M1, Base Dentine 2M2 e Base Dentine 5M3) por 20 ou 40 s. Cp fotoativados sem o bloco cerâmico foram usados como controle. Dezesseis grupos (n=3) foram avaliados. Espectrometria de Micro- ATR/FTIR foi utilizada para avaliar a extensão da polimerização de todos os cp depois de 24 h. A %GC foi calculada e os dados foram analisados através de ANOVA 1-fator e teste de Tukey ( =0,05). Para avaliar adesão, a dentina da superfície oclusal de 80 molares humanos hígidos foi exposta e condicionada com ácido fosfórico 37% e adesivo (Excite DSC). Oitenta blocos (7,2 x 7,2 x 2,5 mm) da mesma cerâmica, nas cores Base Dentine 0M1 e Base Dentine 5M3, foram confeccionados de acordo com as instruções do fabricante. A superfície cerâmica foi tratada com ácido fluorídrico 10% por 60 s e silanizada. Os blocos cerâmicos de cada cor foram cimentados... / The aim of this study was to evaluate the translucency of different ceramic shades, degree of conversion of different resin cement and the bond strength between a feldspathic ceramic and dentin using different resin cement and ceramic shades, and the activation time. The hypothesis is the darker the resin cement and ceramic, lower the translucency; the lower the degree of monomers conversion, lower the bond strength, then the activation time should be higher. Three discs of Vita VM7 ceramic with 20 x 2 mm and shades: Base Dentine 0M1, Base Dentine 2M2 and Base Dentine 5M3, and two discs with 20 x 2.5 mm of the same ceramic and shades: Base Dentine 0M1 and Base Dentine 5M3 were used to determine the translucency percentage of each sp using the MiniScan espectrophotometer. For measure the degree of conversion (DC), the resin cement (Variolink II; A3 Yellow and transparent) specimens (thickness: 100 μm) were photocured under a ceramic block (2mm-thick; Base Dentine 0M1, Base Dentine 2M2 and Base Dentine 5M3) for 20 or 40 s. Specimen photocured without the ceramic block were used as control. Sixteen groups (n=3) were evaluated. Micro-ATR/FTIR spectrometry was used to evaluate the extent of polymerization of all sp after 24 h. The %DC was calculated and the data were analyzed using ANOVA 1-way and Tukey test ( =0,05). For the microtensile bond strength test, the occlusal dentin surface of eighty molars were exposed and etched with 37% phosphoric acid and an adhesive (Excite DSC) was applied. Eighty blocks (7.2 x 7.2 x 2.5 mm) of Base Dentine 0M1 and Base Dentine 5M3 of Vita VM7 ceramic were produced according to the manufacturers. The ceramic surface was etched with 10% hydrofluoric acid for 60 s, followed by the application of a silane agent and a dualcured resin cement (Variolink II; base and catalyst: A3 Yellow; base and catalyst: transparent), according to the manufacturers’ ...(Complete abstract click electronic access below)
54

Efeito da neutralização e remoção sônica do precipitado do ácido fluorídrico na resistência à fratura de coroas cerâmicas

Zogheib, Lucas Villaça [UNESP] 06 July 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-07-06Bitstream added on 2014-06-13T21:07:04Z : No. of bitstreams: 1 zogheib_lv_dr_sjc.pdf: 837093 bytes, checksum: 4dc61b2def9629ca9d60de96c6bceb65 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Testou-se o efeito de diferentes formas de tratamento da superfície cerâmica após condicionamento com ácido hidrofluorídrico (HF) na resistência à fratura de coroas cerâmicas à base de dissilicato de lítio. Quarenta terceiros molares humanos receberam um preparo convencional para coroa total. Após escaneamento digital dos preparos, blocos cerâmicos foram usinados pelo sistema CAD/CAM para obtenção das coroas. A espessura da película de cimento das coroas ao preparo foi verificada com silicone de adição. As coroas foram distribuídas nos 4 grupos conforme o tratamento da superfície cerâmica (n=10): (HF)- HF à 4.9% por 20s + spray ar-água por 30s; (HFN)– HF + agente neutralizador por 5 min (N); (HFU) – HF + banho sônico por 5 min (U); e (HFNU)– HF + N + U. Após aplicação de uma camada de silano (60s), as coroas foram cimentadas com cimento resinoso dual. Uma carga compressiva de 1000Kg foi aplicada no centro da face oclusal da coroa com velocidade de 1 mm/min até a fratura. Os dados foram analisados por ANOVA e Tukey (α=0,05). A carga média de fratura (Kgf) foi: HF = 169,92 ± 21,37; HFN = 187,34 ± 34,79; HFU = 166,63 ± 40,22 e HFNU = 175,26 ± 40,22. O tratamento da superfície cerâmica após condicionamento ácido não influenciou significativamente (p>0.05) na resistência à fratura das coroas cerâmicas testadas, sugerindo que é desnecessário qualquer tratamento adicional para remoção de resíduos após o uso de HF e lavagem com jato de água-ar / The effect of different ceramic surface post hydrofluoric acid (HF) etching cleaning protocols in the fracture strength of lithium dissilicate glass ceramic crowns were evaluated. Forty maxillary third human molars received a conventional full preparation. Crowns were obtained from the digital scanning of the preparations and CAD/CAM blocks machining. Crown cement film thickness was evaluated with vinyl polysiloxane. The crowns were allocated in 4 groups according to the ceramic surface treatment (n=10): (HF)- 4.9% HF for 20s + water spray for 30s; (HFN)- HF + neutralizing agent for 5 min (N); (HFU) -: HF+ sonic bath for 5 min (U) and (HFNU): HF + N + U. After a silane coat (60s), crowns were cemented with dual cure cement. A compressive load of 1000Kg was applied in the occlusal surface center at crosshead speed of 1mm/min until the fracture. Data were analyzed by one-way ANOVA and Tukey tests (α = 0.05). Fracture strength mean for each group was (Kgf): HF = 169.92 ± 21.37; HFN = 187.34 ± 34.79; HFU = 166.63 ± 40.22 e HFNU = 175.26 ± 40.22. There was no statistical difference as the surface treatment (p>0.05) suggesting that it is not necessary any additional ceramic surface treatment in order to remove debris after using of HF and air-water spray rinsing
55

Tenacidade à fratura e dureza de porcelana feldspática adicionada de óxido de zircônio: efeito da concentração e da temperatura de sinterização

Ribeiro, João Gustavo Rabelo [UNESP] 23 July 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-07-23Bitstream added on 2014-06-13T20:45:51Z : No. of bitstreams: 1 ribeiro_jgr_dr_arafo.pdf: 2214278 bytes, checksum: 727777eca67e65454c09d32b238ea332 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar o efeito da adição de óxido de zircônio, em diferentes concentrações e temperaturas de sinterização, na tenacidade à fratura (KIC) e na dureza Vickers (HV) da porcelana feldspática Duceragold. Foram confeccionados discos cerâmicos (9,0 x 3,0mm; n=10) para os grupos: (G1) Duceragold sem adição de ZrO2, (G2) Duceragold adicionada de 1% de ZrO2, (G3) 2% de ZrO2, (G4) 3% de ZrO2, (G5) 4% de ZrO2, (G6) 5% de ZrO2, (G7) 6% de ZrO2 e (G8) 7% de ZrO2, sinterizados a: (a) 800 ºC, (b) 850 ºC, (c) 900 ºC, (d) 950 ºC e (e) 1000 ºC, totalizando 400 corpos-de-prova. Após a sinterização, em forno Alumini Press, procedeu-se sua inclusão e polimento até lixa 1500 em politriz. A HV foi mensurada em durômetro Buelher, com carga de 9,8 N, por 20 segundos; as imagens obtidas foram capturadas por meio de câmera JVC e os cálculos de KIC, executados com auxílio do software Laica. Para observação da superfície das amostras, foram realizadas fotomicrografias por MEV. Os resultados de KIC e HV foram submetidos a ANOVA e teste de Tukey (p!0,05). Observou-se que, independentemente da temperatura de sinterização, o aumento da concentração de óxido de zircônio, aumenta o KIC, todavia, a partir de 6%, a HV diminui; independentemente da concentração, o aumento da temperatura de sinterização proporciona aumento dos valores de HV, contudo, temperaturas de 950ºC e 1000ºC diminuem o KIC; com o aumento da concentração de óxido de zircônio e da temperatura de sinterização, aumentam o número de poros tanto na fase vítrea da porcelana, quanto na fase dispersa de zircônia. Considerando as propriedades estudadas e a caracterização da superfície, pode-se observar que as amostras com adição de até 4% de óxido de zircônio à porcelana feldspática Duceragold, sinterizadas em temperaturas de até 900ºC apresentam-se como as mais promissoras. / The objective of this study was to evaluate the effect of adding zirconium oxide at different concentrations and temperatures of sintering, on the fracture toughness (KIC) and Vickers hardness (HV) of feldspathic porcelain Duceragold. Ceramic discs were prepared (9.0 x 3.0 mm, n = 10) for the groups: (G1) Duceragold without the addition of ZrO2, (G2) Duceragold added 1% of ZrO2, (G3) 2% of ZrO2, (G4) 3% of ZrO2, (G5) 4% of ZrO2, (G6) 5% of ZrO2, (G7) 6% of ZrO2 and (G8) 7% of ZrO2, sintered at: (a) 800 ºC, (b) 850 ºC, (c) 900 ºC, (d) 950 °C and (e) 1000 ºC, totaling 400 specimens of the samples. After sintering at Alumini Press furnace, inclusion and polishing by sandpaper polishing (# 1500) were proceeded. The HV was measured in a Buelher durometer, with a load of 9.8 N for 20 seconds, the images were captured using a JVC camera and calculation of KIC, performed with the aid of software Laica. To observe the surface of the samples were performed by SEM photomicrographs. The results of KIC and HV were submitted to ANOVA and Tukey's test (p ! 0.05). It was observed that regardless of sintering temperature, the concentration of zirconium oxide, increases the KIC, however, from 6%, HV decreases; regardless of the concentration, the increase of sintering temperature gives increased HV values, however, temperatures of 950 °C and 1000 °C decrease the KIC; with increasing concentration of zirconium oxide and sintering temperature, increase the number of pores in the vitreous and dispersed phase of zirconia. Considering the studied properties and characterization of the surface can be observed that the samples with the addition of up to 4% zirconium oxide in Duceragold feldspathic porcelain, sintered at temperatures up to 900 º C are presented as the most promising.
56

Análise in vitro da estabilidade de cor e rugosidade superficial de braquetes ortodônticos cerâmicos

Oliveira, Cibele Braga de [UNESP] 06 July 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-07-06Bitstream added on 2014-06-13T20:57:09Z : No. of bitstreams: 1 oliveira_cb_me_arafo.pdf: 821709 bytes, checksum: 552c0a23690dada1cca43d4d6e5259d1 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este estudo objetivou analisar, in vitro, a estabilidade de cor e rugosidade superficial de braquetes cerâmicos após imersão em soluções corantes. Sete braquetes cerâmicos de incisivo central superior direito de quatro marcas comerciais foram testados: dois monocristalinos e dois policristalinos. Os braquetes foram imersos em quatro soluções corantes (café, vinho tinto, Coca-Cola e chá preto) e em saliva artificial separadamente nos seguintes tempos: T0 (mensuração inicial), T1, T2, T3 e T4 (24 horas, 7,14 e 21 dias respectivamente).Outros sete braquetes de cada marca comercial foram imersos nas mesmas soluções e em tempos iguais aos anteriores, porém com intervalos de escovação diários. As alterações de cor foram avaliadas por espectrofotômetro de reflectância e a rugosidade superficial por meio de um Rugosímetro. Os dados foram avaliados pela Análise de Perfis Multivariados, Análise de Variância (ANOVA), teste de comparação múltipla de médias e Teste t de Student. Com base nos resultados, houve alteração perceptível de cor em todos os braquetes cerâmicos após 21 dias de imersão nas soluções de café (ΔE do Allure = 7,61, Inspire Ice = 6,09, Radiance=6,69, Transcend=7,44), chá preto (ΔE do Allure = 6,24, Inspire Ice = 5,21, Radiance=6,51, Transcend=6,14) e vinho tinto (ΔE do Allure =6,49 , Inspire Ice = 4,76, Radiance=5,19, Transcend=5,64), porém a alteração não foi perceptível para a Coca-Cola e saliva artificial (ΔE<3,7). Os braquetes submetidos à escovação apresentaram médias de alteração de cor significativamente menores e não perceptíveis, exceto para o chá preto. Rugosidade: Média Ra do Allure =0,277, Inspire Ice =0,262, Radiance=0,177, Transcend=0,367. A rugosidade variou apenas com o tempo de imersão. Cocluiu-se que houve alteração de cor dos braquetes cerâmicos quando imersos nas soluções, porém, apenas com o café... / This study aimed to analyze in vitro the color stability and surface roughness of ceramic brackets after immersion in dye solutions. Seven ceramic brackets, upper right central incisor of four commercial brands were tested: two monocrystalline and two polycrystalline. The brackets were immersed separately in four staining solutions (coffee, red wine, Coca-Cola and black tea) and in artificial saliva at following times: T0 (initial measurement), T1, T2, T3 and T4 (24 hours, 7.14 and 21 days respectively). Other seven brackets of each brand were immersed in the same solutions and at same times as previous, but with brushing daily. The changes in color were evaluated by reflectance spectrophotometer and the surface roughness by a surface roughness gauger. The data were evaluated by Multivariate Analysis Profiles, Analysis of Variance (ANOVA), Multiple Comparison Test of means and Test t Student. Based on the results, there was perceptible change of color in all ceramic brackets after 21 days of immersion in coffee solution (ΔE of Allure = 7.61, Inspire Ice = 6,09, Radiance=6,69, Transcend=7,44), black tea (ΔE of Allure = 6,24, Inspire Ice = 5,21, Radiance=6,51, Transcend=6,14) and red wine (ΔE do Allure =6,49 , Inspire Ice = 4,76, Radiance=5,19, Transcend=5,64), but the change was not perceptible to the Coca-Cola and artificial saliva (ΔE <3.7). The brackets that were submitted to brushing showed average color change significantly smaller and not visible, except for black tea. Roughness: Ra Average of Allure = 0.277, Inspire Ice = 0.262, Radiance = 0.177, Transcend = 0.367. The roughness changed with the immersion time. It was cocluded that there was a change in color of ceramic brackets when immersed in the solutions, but only with coffee, black tea and red wine that change was perceptible. The monocrystalline or polycrystalline structure doesn’t affect in the form of staining... 9Complete abstract click electronic access below)
57

Avaliação do brilho, rugosidade e integridade da superfície de cerâmicas odontológicas após o polimento, abrasão por escovação e repolimento das superfícies / Evaluation of surface gloss, roughness and integrity of dental ceramics after polishing, mechanical toothbrushing and repolishing

Ursi, Wagner José Silva 02 March 2011 (has links)
Orientador: Lourenço Correr Sobrinho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-17T15:22:38Z (GMT). No. of bitstreams: 1 Ursi_WagnerJoseSilva_D.pdf: 1229988 bytes, checksum: 2fcbeb63eb27770fcbe7f8c7c3ecdd07 (MD5) Previous issue date: 2011 / Resumo: O objetivo neste estudo foi avaliar a influência de sistemas de polimento, da escovação mecânica e do repolimento sobre o brilho, rugosidade e morfologia da superfície de materiais cerâmicos. Três cerâmicas foram avaliadas: IPS Eris (Ivoclar Vivadent), Vita VM7 (VITA Zahnfabrik) e Cercon CS (Degudent). Trinta amostras cilíndricas padronizadas de cada material foram confeccionadas e aleatoriamente divididas em 3 grupos (n=10) sendo que cada grupo foi submetido a um dos três procedimentos de polimento (taça de borracha; disco de feltro+pasta diamantada; taça de borracha + disco de feltro + pasta diamantada). Após o polimento, o brilho da superfície polida foi mensurado com medidor de brilho (ZGM 1120 Glossmeter - Zehntner) e a rugosidade avaliada através de rugosímetro (Surfcorder SE1700 - Kosaka Lab.). As amostras foram submetidas a 30.000 ciclos mecânicos de escovação, utilizando solução de dentifrício e água deionizada. Após a escovação, as mensurações de brilho e rugosidade foram repetidas. Em seguida, as amostras foram submetidas novamente aos procedimentos de polimento, e o brilho e a rugosidade avaliados novamente. Inicialmente foi realizada análise exploratória dos dados pelo aplicativo GUIDED DATA ANALYSIS do SAS (SAS, 2008). A seguir, os dados foram analisados, segundo o conceito de medidas repetidas no tempo, empregando o procedimento PROC MIXED e teste de Tukey-Kramer. Adicionalmente, amostras polidas, escovadas e repolidas foram examinadas em microscopia eletrônica de varredura (5600LV - Jeol) para avaliação qualitativa da integridade da superfície. Com base nos resultados encontrados, pode-se concluir que a superfície dos materiais cerâmicos foi resistente aos efeitos da escovação mecânica dentro das variáveis utilizadas, e que, o uso da pasta diamantada e disco de feltro, embora tenha se mostrado eficiente na diminuição da rugosidade de superfície (Ra) para a maioria das cerâmicas avaliadas, não foi capaz de alterar os valores originais de brilho superficial. / Abstract: The purpose of this in vitro study was to evaluate the influence of polishing systems, mechanical toothbrushing and repolishing on surface gloss, roughness and morphology of dental ceramics. Three ceramic systems were evaluated: IPS Eris (Ivoclar Vivadent), Vita VM7 (VITA Zahnfabrik) and Cercon CS (Degudent). Thirty standardized cylindrical specimens of each material were fabricated and ramdomly divided in three groups (n=10), each group being submitted to one of the three polishing protocols (rubber cup; felt disc + diamond polishing paste; rubber cup + felt disc + diamond polishing paste). After polishing, surface optical gloss was determined using a gloss meter (ZGM 1120 Glossmeter - Zehntner) and surface roughness was measured with a surface profilometer ( Surfcorder SE 1700 -Kosaka Lab.). All specimens were submitted to 30,000 strokes at 2 Hz, with a dentifrice-water slurry. After mechanical toothbrushing, gloss and roughness measurements were evaluated again. Specimens were then repolished and submitted to gloss and roughness evaluations once more. Data were submitted to PROC MIXED and Tukey-Kramer tests. Aditionaly, randomly assigned specimens were evaluated for qualitative surface integrity under scanning electron microscopy (5600 LV-Jeol). Based on the results and the limitations of this in vitro study, it could be concluded that the surface of the ceramic materials tested was resistant to simulated toothbrushing challenge, and, the use of felt disc and diamond polishing paste, showed to be efficient in reducing surface roughness (Ra) for the majority of the tested ceramics, although unable to alter original surface gloss values. / Doutorado / Materiais Dentarios
58

Morfologia da superficie e resistencia da união de ceramica IPS Empress Esthetic submetida a diferentes tratamentos / Bond strenght and surface/interface morphology of luting polymers and glass ceramic etched for different periods

Naves, Lucas Zago, 1981- 13 August 2018 (has links)
Orientadores: Lourenço Correr Sobrinho, Carlos Jose Soares / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T12:11:57Z (GMT). No. of bitstreams: 1 Naves_LucasZago_M.pdf: 3732245 bytes, checksum: f19061d71b96dbce2d54cda8b37f2ba9 (MD5) Previous issue date: 2009 / Resumo: Este estudo avaliou a morfologia de superfície e resistência de união ao microcisalhamento entre a cerâmica reforçada por leucita IPS Empress Esthetic (Ivoclar- Vivadent) e o cimento resinoso Variolink II (Ivoclar-Vivadent), em diferentes tempos de condicionamento da cerâmica, com e sem aplicação do adesivo após o uso do silano. Setenta e dois discos cerâmicos (6mm de diâmetro x 2mm de espessura) foram confeccionados, embutidos em resina e divididos em 12 grupos (n=6), definidos pelo tempo condicionamento com ácido fluorídrico 10% e aplicação ou não de adesivo após o uso do silano: G1 e G7 - 10s de condicionamento ácido, G2 e G8 - 20 s; G3 e G9 - 40 s; G4 e G10 - 60 s; G5 e G11 - 120 s e G6 e G12 - 60 + 60s. O silano foi aplicado em todos os grupos e metade dos grupos (de G7 a G12) receberam uma camada do adesivo (Scotchbond MP - 3M/ESPE). Molde de elastômero com dois orifícios cilíndricos (1,2mm de diâmetro x 2mm de altura) foi adaptado sobre a superfície da cerâmica para a construção de dois cilindros por amostra, totalizando 12 cilindros por grupo. Para tal, os orifícios foram preenchidos com o cimento resinoso (Variolink II), fotoativados por 40 s e submetidos ao ensaio de resistência de união ao microcisalhamento a velocidade de 0,5mm/min. e o padrão de fratura foi analisado. Os dados foram submetidos à Análise de Variância e ao teste de Student-Newman-Keul (p<0,05). A topografia e a interface de união foram avaliadas em MEV. A resistência de união ao microcisalhamento (MPa) foi 19,4±3,5 (G1), 22,3±5,1 (G2), 22,2±3,2 (G3), 17,8±2,1 (G4), 15,3±3,0 (G5), 14,3±1,8 (G6) para os grupos tratados com silano, e 17,4±4,8 (G7), 21,3±2,1 (G8), 21,1±2,3 (G9), 24,7±5,8 (G10), 20,4±2,2 (G11) e 18,5±4,6 (G12) para os grupos tratados com silano + adesivo. Houve redução de falhas adesivas e aumento das mistas com o aumento do tempo de condicionamento para os grupos tratados com silano e equilíbrio da falhas adesivas e mistas para os grupos tratados com silano + adesivo, exceto para os grupos G11 e G12 onde houve predominância de falhas mistas. Pouca alteração na topografia de superfície foi detectada nas amostras condicionadas por 10s, canais apresentando sulcos profundos puderam ser notados em praticamente toda a extensão das superfícies cerâmicas recondicionadas (60+60s - G6 e G12). Espaços não-preenchidos ao longo da interface cerâmica-cimento resinoso foram detectados em intensidade crescente a partir de 60s de condicionamento, quando apenas o silano foi aplicado, enquanto um preenchimento homogêneo, caracterizado por íntimo contato com a cerâmica pode ser percebido quando o adesivo foi utilizado, exceto para o grupo recondicionado - G12. / Abstract: This study evaluated the influence of etching times on surface/interface morphology and micro-shear bond strength to Empress Esthetic leucite-reinforced glass ceramic (Ivoclar-Vivadent), with or without application of an unfilled resin after silane. Ceramic discs were divided into 12 groups (n = 6), defined by the etching time with 10% hydrofluoric acid: G1 and G7 - etching for 10s, G2 and G8 - 20 s; G3 and G9 - 40 s; G4 and G10 - 60 s; G5 and G11 - 120 s and G6 and G12 - 60 + 60s. Half of the groups (G7 to G12) received a layer of unfilled resin (Scotchbond MP/ 3M ESPE) after silane coupling. Micro-shear bonding test using Variolink II resin cement (Ivoclar-Vivadent) was performed, and data submitted to two-way ANOVA and Student-Newman-Keuls' test (p < 0.05). Evaluation of the etching pattern and bonding interfaces was conducted by Scanning Electron Microscopic (SEM). Means micro-shear bond strengths (MPa) were 19.4±3.5 (G1), 22.3±5.1 (G2), 22.2±3.2 (G3), 17.8±2.1 (G4), 15.3±3.0 (G5), 14.3±1.8 (G6) for groups treated with silane, and 17.4±4.8 (G7), 21.3±2.1 (G8), 21.1±2.3 (G9), 24.7±5.8 (G10), 20.4±2.2 (G11) e 18.5±4.6 (G12) for groups treated with silane and unfilled resin. Poor etching topography was detected on 10s etched surfaces, whereas fissures forming deep grooved channels were extensively observed in 120s and 60+60s ceramics surfaces. Unfilled spaces underlying the ceramic-resin cement interface were detected when only silane was applied. Fully completion of the irregularities on 60s and 120s samples were detected using the unfilled resin, although this material was unable to completely fill the irregularities on 60+60s (G12) ceramic. When only silane was applied, the 60s and the groups etched for longer periods (120 and 60+60s - G5 and G6) showed lower bond strengths, but when both silane and unfilled resin were applied, all etching times generally showed similar values. The etching protocol influenced the surface/interface topography and bond strength to ceramic. The application of unfilled resin was able to infiltrate all unfilled spaces beneath the ceramic-resin cement interface detected when only silane was applied, except on the re-etched (60+60s - G12) ceramic. / Mestrado / Materiais Dentarios / Mestre em Materiais Dentários
59

Efeito do tipo de revestimento estetico e da eletroerosão sobre a desadaptação de infra-estruturas implanto-suportadas fundidas em titanio c.p. / The influence of the veneering application and Spark erosion on the misfit level of implant-supported frameworks

Nakaoka, Marcia Mika 22 June 2007 (has links)
Orientador: Marcelo Ferraz Mesquita / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-09T19:46:50Z (GMT). No. of bitstreams: 1 Nakaoka_MarciaMika_D.pdf: 1091285 bytes, checksum: 76d1bd5bef1fb0bee757a9f929be3f3a (MD5) Previous issue date: 2007 / Resumo: As distorções oriundas das técnicas de aplicação de revestimentos estéticos sobre infra-estruturas metálicas de próteses fixas podem resultar em margens cervicais desadaptadas. Dessa forma, este trabalho propôs-se a avaliar o efeito do tipo de revestimento estético, da simulação dos ciclos de cocção da cerâmica, e da aplicação da eletroerosão, sobre o desajuste de infra-estruturas implanto-suportadas fundidas em titânio comercialmente puro (Ti c.p.). Foi utilizada uma matriz metálica contendo 5 pilares intermediários do tipo Microunit. Sobre ela, foram enceradas 40 infra-estruturas, posteriormente fundidas em Ti c.p. (Tritan, Dentaurum, Alemanha). Para cada infraestrutura foi confeccionado um index, com 5 análogos parafusados em cada infra-estrutura. Esse conjunto foi posicionado em microscópio para a mensuração dos desajustes antes da aplicação dos revestimentos estéticos, com a finalidade de avaliar apenas desajuste provocado pela aplicação dos revestimentos estéticos e pelo ciclo de cocção da cerâmica. As infra-estruturas foram separadas, aleatoriamente: G1: resina acrílica ativada termicamente (Clássico, Clássico Artigos Odontológicos Ltda., São Paulo, Brasil); G2: resina fotopolimerizável (Versyo.com, Heraeus Kulzer, Brasil); G3: cerâmica (Triceram, Dentaurum J. P. Winkelstroeter KG ¿ Pforzheim - Alemanha); G4: simulação dos ciclos de cocção da cerâmica. Novamente, após a aplicação dos revestimentos estéticos, foi realizada a avaliação do desajuste marginal sobre o index. Procedeu-se o processo de eletroerosão (Tel Med Technologies, Port Huron, Michigan, EUA). As leituras de desajuste foram realizadas após o aperto com 10 Ncm em um único parafuso, correspondente ao implante A. Através desse procedimento, verificou-se a adaptação dos componentes C e E. O procedimento foi repetido com o outro implante mais distal (E), para mensuração nos implantes A e C. As leituras foram realizadas utilizando microscópio mensurador, com aumento de 120X e precisão de 0,5µm (Micro Vision ¿ Leika, Wetzlar, Alemanha), antes e após aplicação dos revestimentos estéticos, e após o processo de eletroerosão. Os resultados obtidos foram submetidos à Análise de Variância e ao teste de Tukey (p<0,05). Os valores de desajuste marginal das infra-estruturas antes da aplicação dos revestimentos estéticos não apresentaram diferença estatística significante entre si: G1: 29,81 'mu' (+ 10,66); G2: 35,30 'mu' (+ 12,15); G3: 44,75 'mu'(+ 13,73); G4: 38,57 'mu' (+ 16,94). A aplicação dos revestimentos estéticos e a simulação dos ciclos de cocção da cerâmica aumentaram significantemente os valores médios de desajuste marginal para todos os grupos: G1: 221,70 'mu' (+14,11); G2: 81,91 'mu' (+15,71); G3: 233,99 'mu' (+39,18); e G4: 119,75 'mu' (+38,08). Os grupos G1 e G3 não apresentaram diferença estatisticamente significante entre si, mas apresentaram diferença quando comparados aos G2 e G4. Após o processo de eletroerosão, apenas para o grupo G3: 161,16 µm (+36,59 ) a média de desajuste marginal apresentou-se com valor significamente menor. As médias de desajuste marginal para os grupos G1: 198,68 mu' (+34,19); G2: 62,03 'mu' (+17,73) e G4: 87,98 'mu' (+39,32) foram numericamente menores, porém, sem diferença estatística. Como ocorrido anteriormente, os grupos G1 e G3 não apresentaram diferença estatística significante, mas ambos apresentaram diferença quando comparados aos grupos G2 e G4. A partir dos resultados obtidos no presente estudo, conclui-se que os revestimentos estéticos em resina acrílica ativada termicamente e em cerâmica produziram os maiores valores de desajuste marginal para próteses implanto-retidas, enquanto a resina fotopolimerizável, os menores. A aplicação de cerâmica nas infra-estruturas produziu maiores valores de desajuste marginal quando comparado à simples simulação dos ciclos de cocção. O processo de eletroerosão mostrou-se eficaz na redução dos desajustes marginais apenas para o grupo com aplicação da cerâmica / Abstract: The demand for a passive fit of frameworks for osseointegrated endousseous implants abutments is well known, because the tightening of an inaccurate framework to the abutments can transmit stress to the bone-metal interface. The purpose of the present study was to evaluate the influence of the veneering application and porcelain firing cycle on the misfit level of implant-supported frameworks. Forty Ti c.p. (Tritan, Dentaurum, Germany) alloy frameworks were fabricated from a metallic index containing 5 Branemark type multi unit abutments. Analogs of the abutments were positioned to the framework, to construct an index for each framework. This index allowed the observation of the marginal gaps caused by the application of the veneering material. The frameworks were grouped (n=10): 1) heat acrylic resin (Clássico, Clássico, São Paulo, Brazil); 2) light polymerized resin (Versyo.com, Heraeus Kulzer, Brazil); 3) porcelain application (Triceram, Dentaurum - Germany); 4) simulation of porcelain firing cycle. Marginal refinement with spark erosion was conducted on specific equipment (Tel Med Technologies, U.S.A.). The marginal gap was obtained before and after the veneering materials and the spark erosion procedure, following the single screw test protocol (using a tightening force of 10 Ncm). A traveling microscope (STN ¿ Olympus Optical Co. Ltd Japan (120X) was used, tightening 10N in the titanium screw of the extremity distal implant, measuring the gaps at the central and distal implants. Data were subject Analysis of Variance followed by Tukey test (5%). Marginal gap mean values of the frameworks before the veneering application were not significantly different: G1: 29.81 'mu' (+ 10.66); G2: 35.30 'mu' (+ 12.15); G3: 44.75 'mu' (+13.73); G4: 38.57 'mu' (+ 16.94). The application veneering materials and the simulation of porcelain firing cycle increased significantly the misfit mean values of all groups: G1: 221.70 'mu' (+14.11); G2: 81.91 'mu' (+15.71); G3: 233.99 'mu' (+39.18); e G4: 119.75 'mu' (+38.08). There were no significant differences between G1 and G3, but they were significantly different from both G2 and G3. After the spark erosion process, marginal gap mean value decreased significantly only G3 group: 161.16 µm (+36.59). G1: 198.68 'mu' (+34.19); G2: 62.03 'mu' (+17.73) and G4: 87.98 'mu' (+39.32) groups decreased the marginal gap mean values, but not significantly after the spark erosion procedure. As occurred after the application of veneering materials, G1 and G3 groups did not show significant difference, but they both were significantly different from G2 and G4 groups. It can be concluded that heat cured acrylic resin and porcelain produced the highest mean values of marginal gaps, while light cured acrylic resin, the lowest. The application of porcelain produced higher misfit values than the simulation of porcelain firing cycles. After the spark erosion process, marginal gap mean value decreased significantly only porcelain application grou / Doutorado / Protese Dental / Mestre em Clínica Odontológica
60

Influencia do metodo de fotoativação e materiais restauradores indiretos sobre o grau de conversão e dureza Knoop de um cimento resinoso dual / The influence of light curing and indirect restorative materials on conversion degree and Knoop hardness of dual-cured resin cement

Komori, Paula Carolina de Paiva 12 September 2008 (has links)
Orientador: Lourenço Correr Sobrinho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-12T10:14:46Z (GMT). No. of bitstreams: 1 Komori_PaulaCarolinadePaiva_D.pdf: 603004 bytes, checksum: 11e75b4ee3e84d165caa74d684ffbe94 (MD5) Previous issue date: 2008 / Resumo: Os cimentos resinosos têm sido amplamente utilizados devido à capacidade de união ao dente e a prótese fixa e ao sucesso estético. Os cimentos resinosos apresentam ativação química, física ou dupla ativação. Para esses cimentos, quanto maior o grau de polimerização melhores serão suas propriedades. Entretanto, em diversas situações clínicas a polimerização é afetada pela distância da ponta da unidade fotoativadora em relação ao cimento, pela presença de restaurações indiretas ou estrutura dentária. Assim, este estudo avaliou a polimerização de um cimento resinoso de dupla ativação RelyX ARC (RLX), sob diferentes condições. No primeiro estudo para simular uma restauração indireta foram confeccionados discos com 1,4mm de espessura e 8mm de diâmetro das cerâmicas Empress 2 (EMP) e Empress Esthetic (EST), Duceram Plus (DUC) e resina composta Z250 (Z250). Amostras do RLX com 0,8mm de espessura e 5mm de diâmetro, foram fotoativadas diretamente e indiretamente sob o anteparo, com os aparelhos de fotoativação com lâmpada halógena (QTH - 800mW/cm2) e por diodo emissor de luz (LED - 1100mW/cm2). A potência (mW) das fontes de luz foram medidas com um potenciômetro (Ophir) e o espectro da luz emitida foi registrado com espectrômetro (USB 2000), com e sem a presença do anteparo. No segundo estudo as amostras do cimento foram fotoativadas diretamente com QTH ou LED, recebendo diferentes densidades de energia (10, 20, e 30J/cm2). O grau de polimerização do RLX foi mensurado com a porcentagem do grau de conversão pelo método FT-Raman (CD) e dureza Knoop (KHN). Os resultados obtidos CD (%) e KHN foram submetidos à Análise de Variância e teste de Tukey (5%). De acordo com os resultados destes estudos foi possível concluir que o CD e a KHN podem ser influenciadas pelo tipo de aparelho fotoativador, densidade de energia, assim como, pela presença de restaurações indiretas. / Abstract: The resin cements have been widely used because it provide link between prosthesis and tooth structure and esthetic success. Resin cements are available in chemical-cured, light-cured or dual-cured mode. For this type of cements higher polymerization reflects in improvement on properties. However in many clinical situations polymerization is affected by indirect restoration, tooth or distance of light-curing unit tip to cement. This study evaluated the polymerization of dual-cured resin cement RelyX ARC (RLX) in different simulated clinical conditions. The first study simulated indirect restoration with disks of 1.4mm in thickness and 8mm in diameter of Empress 2 (EMP), Empress Esthetic (EST), Duceram Plus (DUC) ceramics, and resin composite Z250 (Z250). Specimens of RLX with 0.8mm in thickness and 5mm in diameter were light-cured directly and indirectly through restorative materials with quartz-tungsten-halogen (QTH 800mW/cm2) or light-emitting diode (LED 1100mW/cm2). The output power energy (mW) emitted by each light-curing unit was measured with the digital power meter (Ophir) and the spectral output emitted by each unit was registered using a spectrometer (USB 2000), directly and through the disks. In the second study, RLX specimens were lightcured directly with QTH or LED with 10, 20 e 30J/cm2 energy densities. The degree of polymerization achieved by RLX was analyzed by conversion degree (CD) using a FT-Raman Spectrometer and Knoop hardness test (KHN). Data of CD (%) and Knoop hardness (KHN) were submitted to Analysis of Variance and to Tukey's test (5%). According to the results of these studies were unable to conclude that CD and KHN can be influenced by the lightcuring units, light energy density and also by the presence of indirect restorations. / Doutorado / Materiais Dentarios / Doutor em Materiais Dentários

Page generated in 0.0497 seconds