• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 15
  • 1
  • Tagged with
  • 16
  • 16
  • 13
  • 10
  • 8
  • 6
  • 5
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo da resistência residual das cerâmicas de dissilicato de lítio submetidas a diferentes protocolos de fadiga / Mechanical behavior study of lithium disilicate ceramic subjected to different cycling protocols

Barcellos, Aline Serrado de Pinho [UNESP] 04 November 2016 (has links)
Submitted by Aline Serrado de Pinho Barcellos null (alinebarcellosodonto@hotmail.com) on 2016-12-18T12:01:55Z No. of bitstreams: 1 dissertaçãoImpressão.pdf: 3771981 bytes, checksum: 5f352cb7c8b67d15d25214beae5fe249 (MD5) / Approved for entry into archive by Felipe Augusto Arakaki (arakaki@reitoria.unesp.br) on 2016-12-20T17:14:58Z (GMT) No. of bitstreams: 1 barcellos_asp_me_sjc.pdf: 3771981 bytes, checksum: 5f352cb7c8b67d15d25214beae5fe249 (MD5) / Made available in DSpace on 2016-12-20T17:14:58Z (GMT). No. of bitstreams: 1 barcellos_asp_me_sjc.pdf: 3771981 bytes, checksum: 5f352cb7c8b67d15d25214beae5fe249 (MD5) Previous issue date: 2016-11-04 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo do estudo foi avaliar o comportamento mecânico de uma cerâmica, à base de dissilicato de lítio, em ensaio de flexão com as extremidades fixas. Este estudo particular tem similaridade com caso real de aplicação de prótese em pacientes, o que melhora a avaliação do material quando comparado a ensaios convecionais como o ensaio de flexão em três pontos, com viga simplesmente apoiada. Para isso os corpos de prova foram submetidos à três tipos de envelhecimento: ciclagem mecânica, ciclagem termomecânica, ambas de acordo com os protocolos utilizados na literatura, e ciclagem intrabucal. A ciclagem intrabucal foi realizada por meio da utilização de um dispositivo intrabucal semelhante a uma placa oclusal, na qual foram instalados os corpos de prova, por meio de um dispositivo metálico próprio. Estas placas foram utilizadas em dez voluntários por oito horas, durante o período noturno. As amostras foram posteriormente submetidas ao ensaio mecânico de flexão de três pontos com as extremidades engastadas, para avaliação da resistência residual. Os resultados de resistência residual foram submetidos à análise estatística descritiva (média e desvio padrão) e inferencial, mediante o teste paramétrico de análise de variância (ANOVA) um fator e o teste de Tukey ( = 0,05). As amostras representativas de cada grupo foram observadas em microscópio eletrônico de varredura para análise fractográfica. O tipo de ciclagem influenciou no comportamento mecânico da cerâmica, apresentando significância estatística (p = 0,000) e o grupo de ciclagem intrabucal mostrou a menor resistência à flexão. A origem da fratura foi na zona de tração, porém observou-se uma origem secundária localizada em zona de torção. Pode-se concluir que os tipos de ciclagens influenciaram no comportamento mecânico da cerâmica de dissilicato de lítio. As ciclagens mecânica, termomecânica e intrabucal reduziram a resistência à flexão do material. A ciclagem intrabucal foi a que mais reduziu a resistência residual em flexão deste tipo de cerâmica. / This study aimed to evaluate the behavior of lithium disilicate ceramic in similar condition to a partial fixed prosthesis of three elements by subjecting to three types of aging (n=10): mechanical cycling, thermomechanical cycling, both according to the protocols used in the literature, and intraoral cycling. The intraoral cycling was accomplished by using an intraoral device, which is similar to an occlusal splint. They were installed with the samples (CP) by means of a metallic device that was fixed in balanced contact condition with the remainder of the occlusal surface of the plate. These plates were used in ten volunteers for eight hours during the evening. After fatigue, the samples were subjected to three-point bending tests with clamped ends to evaluate the residual strength. The residual strength results were submitted to descriptive statistics (mean and standard deviation) and inferential by the parametric analysis of variance (ANOVA), with one factor and Tukey test ( = 0.05). In addition, representative samples of each group were observed in a scanning electron microscope (SEM) for fractographic analysis. The cycling condition influenced the mechanical behavior of ceramic with statistical significance of (p = 0,000), and the intraoral cycling group showed the lowest residual flexural strength. In fractographic analysis, they showed that the origin of fracture was in the tensile zone, but there was a secondary fracture origin represented by a twisted zone. Therefore, all types of cycling influenced the flexural strength of the material.
2

Influencia dos tipos de tratamentos sobre a resistencia de união entre dentes e resinas acrilicas / Influence of types of treatments on the strength bond between teeth and acrylic resins

Naoe, Hilka Tiemi 02 March 2009 (has links)
Orientador: Rafael Leonardo Xediek Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-12T19:07:37Z (GMT). No. of bitstreams: 1 Naoe_HilkaTiemi_M.pdf: 1024541 bytes, checksum: 92dfb7adacf4acd2b08826fb3278ce7c (MD5) Previous issue date: 2009 / Resumo: O objetivo neste estudo foi verificar a resistência da união ao cisalhamento entre as resinas acrílicas Clássico ou Onda-Cryl e o dente Trubyte-Biotone, sob a influência de diversas formas de retenção, compreendendo nenhum tratamento (controle), perfuração com broca, jateamento com partículas de óxido de alumínio, condicionamento com monômero, condicionamento com primer e interações. Noventa matrizes retangulares, medindo 20mm de largura por 35mm de comprimento, foram confeccionadas com cera utilidade e incluídas na parte inferior de muflas metálicas ou plásticas, com gesso pedra tipo III Herodent. As matrizes retangulares foram removidas depois de plastificadas com água em ebulição e os moldes de gesso revestidos com silicone laboratorial, nos quais foram incluídos um dente molar com a base contendo um cilindro de cera de 6mm de diâmetro por 25mm de comprimento. O conjunto dente-cilindro em cera foi recoberto com uma camada de silicone e a mufla preenchida com gesso pedra. Depois da presa do gesso, o conjunto dente-cilindro em cera foi removido, o bastão em cera retirado, o dente limpo com detergente e as bases submetidas aos tratamentos de acordo com o protocolo e recolocadas nos moldes de silicone. As resinas acrílicas termopolimerizáveis foram proporcionadas na relação volumétrica de 3/1 (polímero/monômero), adaptadas na fase plástica nos moldes de silicone e prensadas em prensa hidráulica de bancada. As muflas metálicas foram levadas à termopolimerizadora automática para polimerização da resina no ciclo em banho de água à temperatura de 74ºC durante 9 horas. As muflas plásticas foram colocadas em forno de microondas para polimerização da resina, calibrado com 900W de potência, para o ciclo de: fase I - 3 minutos com 40% da potência, fase II - 4 minutos com potência 0% e fase III - 3 minutos com 90% da potência e esfriamento das muflas em bancada. Depois da demuflagem, os corpos-de-prova foram armazenados em água destilada à temperatura de 37ºC durante 24 horas. Depois da armazenagem, os corpos-de-prova foram submetidos ao teste de resistência ao cisalhamento na máquina de ensaios universal Instron, com velocidade de 1mm/minuto. Os resultados submetidos à análise de variância e as médias ao teste de Tukey (5%) mostraram que os valores da união entre dentes artificiais e resinas acrílicas não apresentam diferença estatística significativa, quando comparadas independentemente dos tipos de tratamentos. Na análise dos tipos de tratamentos, independentemente da resina acrílica, o grupo que recebeu jateamento+adesivo apresentou média com diferença estatística significativa com o grupo perfurado+adesivo. Os demais grupos não apresentaram diferença estatística significativa. Quando os tratamentos foram considerados em cada resina, na Clássico não houve diferença significativa entre eles e na Onda-Cryl os tratamentos controle e perfurado+adesivo foram diferentes estatisticamente dos grupos jateado+ monômero e jateado+adesivo. Os demais grupos não apresentaram diferenças estatísticas. Na comparação entre resinas, somente o grupo controle apresentou diferença estatística significativa com o maior valor para a resina Onda-Cryl / Abstract: The purpose of this study was to verify the shear bond strength between denture tooth Trubyte-Biotone and the acrylic resins Clássico and Onda-Cryl, under the influence of various forms of treatments, including no treatment (control), retention groove, sandblasting with aluminum oxide particles, monomer application, primer application, and interactions. Ninety wax rectangular mold patterns (20 mm in width and 35 mm in length), were poured into a traditional brass flask or metal with type III dental stone that was proportioned and manipulated following the manufacturer's recommendations. After wax patterns removal, the stone mold was filled with a layer of laboratory silicone putty. Identical model acrylic molar teeth with a wax stick (6mm diameter and 25mm long) attached at the ridge lap surface were partially embedded into the silicone layer. The resultant tooth/wax stick set was then covered with a layer of laboratory silicone putty. After dental stone isolation with petroleum jelly, the flask was completely poured with type III dental stone and pressed in a hydraulic press bench. Following, the tooth/wax stick set was deflasked and the wax stick removed from the tooth ridge lap. The tooth was brushed with a solution of hot water and liquid detergent to eliminate the wax residuos. Heat-cured denture base acrylic resins were prepared using a ratio of volume 3/1(polymer/monomer), adapted on stage in plastic molds made of silicon and pressing into bench hydraulic press. The metal flask were conventional packed, polymerized in a hot water bath at 74oC for 9 hours in polymerizing unit, and deflasked after flask cooling at room temperature. The plastic flask were placed in the microwave oven for curing the acrylic resin, calibrated with 900W of power for the cycle: Phase I - 3 minutes with 40% of the power, phase II - 4 minutes with 0% power and phase III - 3 minutes with 90% of the power and flask cooling at room temperature. After deflasked, all specimens were stored in distilled water at a temperature of 37oC for 24 hours, and they were performed the shear bond testing in an Instron machine, using a cross-speed of 1mm/minuto. The results were submitted to ANOVA and Tukey's test (5%) showed that the values of the shear bond strength between artificial teeth and acrylic resins were not statistically significant when compared regardless of the types of treatments. In the treatment type analysis, regardless of acrylic resin, the sandblasting+adhesive group showed bond strength values with significant statistically difference when compared to groove+adhesive group. The other experimental groups were not statistically different. When the treatments were considered in each resin, in the Classico acrylic resin there was no significant difference between them. In Onda-Cryl, control and groove+adhesive treatments were statistically different of the sandblasting+monomer and sandblasting+adhesive groups, while the other showed no statistical differences. In the comparison between resins, only the control group showed statistically significant differences, with the greatest value for the Onda-Cryl acrylic resin / Mestrado / Mestre em Materiais Dentários
3

Processamento de próteses totais: influência de 4 técnicas na alteração daposição dos dentes artificiais. / The processing of complete denture: influence of four techniques in artificial teeth movement.

Barnabé, William 03 April 2000 (has links)
O processamento de resinas acrílicas utilizadas na confecção de bases de prótese envolve alterações dimensionais e distorções da base e movimentação dos dentes artificiais que podem levar à não utilização das próteses por desadaptação, dificuldade de engrenamento dos dentes e estética. Esse estudo avaliou a relação entre a movimentação dos dentes artificiais com os procedimentos de inclusão, prensagem e polimerização das bases de próteses totais. Foram utilizadas 64 amostras, divididas em quatro grupos de 16 (8 inferiores e 8 superiores) que receberam o seguinte tipo de inclusão, prensagem e processamento: a) grupo 1: neste grupo todas as amostras foram incluídas em muflas reforçadas de fibra de vidro, com muralha de silicona, prensagem por uma hora e polimerização em microondas, b) grupo 2: neste grupo todas as amostras foram incluídas em muflos metálicos, com muralha de silicona, prensagem por 12 horas e polimerização em banho de água, utilizando o ciclo de curta duração, c) grupo 3: neste grupo todas as amostras foram incluídas em muflas reforçadas de fibra de vidro, adaptadas para injetora de acrílico, com muralha de gesso pedra e polimerização em microondas, uma hora após a injeção do molde e d) grupo 4: neste grupo todas as amostras foram incluídas em muflos metálicos, com muralha de silicona, prensagem por uma hora e polimerização em banho de água, utilizando o ciclo de curta duração. Com os resultados obtidos podemos concluir que: a) todas as amostras sofreram contração após o processamento, b) a técnica com menor movimentação dos dentes artificiais foi a técnica 1, que apresentou diferença estatisticamente significativa em relação às demais c) quando comparados os arcos superiores e inferiores, independente da técnica e das medidas avaliadas, não se percebeu diferença estatisticamente significativa d) O tempo de prensagem, após a inclusão e antes da polimerização das próteses, interferiu na movimentação dos dentes artificiais e e) a medida que apresentou maior alteração foi a distância entre os molares, com diferença estatisticamente significativa com as demais. / The processing of acrylic resins used in the construction of complete denture bases involve dimensional alterations, distortion and artificial tooth movement which may prevent the prosthesis from being used due to discomfort, inadequate occlusion and esthetics. This study evaluated the relationship between artificial tooth movement, with the procedures of inclusion, compression and polymerization of complete dentures bases. The sixty-four samples utilized were divided into four groups of 16 (8 lower and 8 upper) which received the following type of inclusion, compression and processing: a) group 1: in this group all samples were included in resin-fiber reinforced flasks, with a silicone mould, compression for one hour and microwave polymerization; b) group 2: in this group all samples were included in metallic flasks, with a silicone mould, compression for 12 hours and thermopolymerization in water bath, using a short duration cycle; c) group 3: in this group all samples were included with gypsum stone mould using an acrylic injector to insert the resin inside the flasks, followed by microwave polymerization, one hour after mould injection and; d) group 4: in this group all samples were included in metallic flasks, with a silicone mould, compression for one hour and thermopolymerization in water bath, using short duration cycle. According to the results the following conclusions were drawn: a) contraction was observed in all samples after processing; b) group 1 presented statistically significant less artificial tooth movement, relative to the others; c) comparing the upper and lower arches, regardless of the technique and measurements evaluated, no statistically significant difference was found; d) the compression time following inclusion and before prostheses polymerization had a negative effect on artificial tooth movement and e) the biggest discrepancies were found in the distance between contralateral molars, with statistically significant difference to other measurements.
4

Tenacidade à fratura e dureza de porcelana feldspática adicionada de óxido de zircônio: efeito da concentração e da temperatura de sinterização

Ribeiro, João Gustavo Rabelo [UNESP] 23 July 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-07-23Bitstream added on 2014-06-13T20:45:51Z : No. of bitstreams: 1 ribeiro_jgr_dr_arafo.pdf: 2214278 bytes, checksum: 727777eca67e65454c09d32b238ea332 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar o efeito da adição de óxido de zircônio, em diferentes concentrações e temperaturas de sinterização, na tenacidade à fratura (KIC) e na dureza Vickers (HV) da porcelana feldspática Duceragold. Foram confeccionados discos cerâmicos (9,0 x 3,0mm; n=10) para os grupos: (G1) Duceragold sem adição de ZrO2, (G2) Duceragold adicionada de 1% de ZrO2, (G3) 2% de ZrO2, (G4) 3% de ZrO2, (G5) 4% de ZrO2, (G6) 5% de ZrO2, (G7) 6% de ZrO2 e (G8) 7% de ZrO2, sinterizados a: (a) 800 ºC, (b) 850 ºC, (c) 900 ºC, (d) 950 ºC e (e) 1000 ºC, totalizando 400 corpos-de-prova. Após a sinterização, em forno Alumini Press, procedeu-se sua inclusão e polimento até lixa 1500 em politriz. A HV foi mensurada em durômetro Buelher, com carga de 9,8 N, por 20 segundos; as imagens obtidas foram capturadas por meio de câmera JVC e os cálculos de KIC, executados com auxílio do software Laica. Para observação da superfície das amostras, foram realizadas fotomicrografias por MEV. Os resultados de KIC e HV foram submetidos a ANOVA e teste de Tukey (p!0,05). Observou-se que, independentemente da temperatura de sinterização, o aumento da concentração de óxido de zircônio, aumenta o KIC, todavia, a partir de 6%, a HV diminui; independentemente da concentração, o aumento da temperatura de sinterização proporciona aumento dos valores de HV, contudo, temperaturas de 950ºC e 1000ºC diminuem o KIC; com o aumento da concentração de óxido de zircônio e da temperatura de sinterização, aumentam o número de poros tanto na fase vítrea da porcelana, quanto na fase dispersa de zircônia. Considerando as propriedades estudadas e a caracterização da superfície, pode-se observar que as amostras com adição de até 4% de óxido de zircônio à porcelana feldspática Duceragold, sinterizadas em temperaturas de até 900ºC apresentam-se como as mais promissoras. / The objective of this study was to evaluate the effect of adding zirconium oxide at different concentrations and temperatures of sintering, on the fracture toughness (KIC) and Vickers hardness (HV) of feldspathic porcelain Duceragold. Ceramic discs were prepared (9.0 x 3.0 mm, n = 10) for the groups: (G1) Duceragold without the addition of ZrO2, (G2) Duceragold added 1% of ZrO2, (G3) 2% of ZrO2, (G4) 3% of ZrO2, (G5) 4% of ZrO2, (G6) 5% of ZrO2, (G7) 6% of ZrO2 and (G8) 7% of ZrO2, sintered at: (a) 800 ºC, (b) 850 ºC, (c) 900 ºC, (d) 950 °C and (e) 1000 ºC, totaling 400 specimens of the samples. After sintering at Alumini Press furnace, inclusion and polishing by sandpaper polishing (# 1500) were proceeded. The HV was measured in a Buelher durometer, with a load of 9.8 N for 20 seconds, the images were captured using a JVC camera and calculation of KIC, performed with the aid of software Laica. To observe the surface of the samples were performed by SEM photomicrographs. The results of KIC and HV were submitted to ANOVA and Tukey's test (p ! 0.05). It was observed that regardless of sintering temperature, the concentration of zirconium oxide, increases the KIC, however, from 6%, HV decreases; regardless of the concentration, the increase of sintering temperature gives increased HV values, however, temperatures of 950 °C and 1000 °C decrease the KIC; with increasing concentration of zirconium oxide and sintering temperature, increase the number of pores in the vitreous and dispersed phase of zirconia. Considering the studied properties and characterization of the surface can be observed that the samples with the addition of up to 4% zirconium oxide in Duceragold feldspathic porcelain, sintered at temperatures up to 900 º C are presented as the most promising.
5

Análise in vitro da precisão de técnicas de esplintagem na moldagem de implantes no esquema all-on-four / In vitro analysis of the accuracy of splinting impression techniques using all-on-four system

Pimentel, Gustavo Henrique Diniz [UNESP] 15 October 2014 (has links) (PDF)
Made available in DSpace on 2016-12-09T13:52:22Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-10-15. Added 1 bitstream(s) on 2016-12-09T13:55:26Z : No. of bitstreams: 1 000874738.pdf: 3429941 bytes, checksum: f0746f3294aca82e94682f551d6b7ae5 (MD5) / O assentamento passivo de próteses sobre implantes é fundamental para que o sucesso da reabilitação seja alcançado. A precisão na moldagem de transferência é um dos principais fatores responsáveis por assegurar a adaptação dos componentes. Dentre as várias técnicas propostas, não existe consenso sobre qual é a mais eficaz. O objetivo do presente estudo foi avaliar in vitro a precisão de diferentes métodos de união de transferentes quadrados na moldagem de implantes paralelos e angulados instalados em curva. Para a obtenção do modelo mestre, matrizes metálicas em alumínio foram confeccionadas, apresentando quatro perfurações, em forma de curva, paralelas (prótese protocolo convencional) e anguladas (esquema All-on-four). Foram fixados os análogos e, sobre eles, foram confeccionadas estruturas metálicas. Para os implantes retos, os grupos foram divididos em GSU-R: transferentes quadrados sem união; GUR-R: transferentes quadrados unidos com bastões de resina acrílica autopolimerizável pré-fabricados e GUM-R: transferentes quadrados unidos com haste metálica, cianoacrilato e resina acrílica autopolimerizável. Para os implantes angulados, as mesmas técnicas foram comparadas: GSU-A, GUR-A, GUM-A. A moldagem foi realizada com silicone de adição e moldeira rosqueada para controlar variáveis. Os modelos foram vazados em matriz padronizada com gesso pedra tipo IV. Os modelos obtidos foram armazenados à temperatura ambiente por no mínimo 120 horas até que as medidas das fendas fossem realizadas. Foi utilizada uma lupa LEICA acoplada a uma câmera de vídeo colorida e as mensurações das fendas foram realizadas no programa LEICA QWin. Foi aplicado o teste de Kruskal-Wallis, complementando pelo teste de Dunn, com nível de significância de 5%. Para os implantes retos, foi observada diferença estatisticamente significante entre os grupos...(Resumo completo, clicar acesso eletrônico abaixo) / Passively fitting superstructures are a prerequisite for long-lasting osseointegration of dental implants. Accurate transfer of the implant positions from the mouth to a definitive stone cast is a crucial step for ensuring the adaptation of components. Among the various techniques proposed, there is no consensus on which one is the most effective. The aim of this study was to evaluate in vitro the accuracy of different splinting methods in the impression of implants under standardized laboratory conditions. To obtain the master model, an aluminum metal matrix was developed, presenting four perforations, parallel (simulating conventional prosthesis and angled (simulating All-on-four system). Analogs were fixed and, on them, metal structures were fabricated. For straight implants, the groups were divided into GSUR: non-splinted square transfers; GUR-R: transfers splinted acrylic resin; GUM R: transfers splinted with metal rod, cyanoacrylate and acrylic resin. For angled implants, the same techniques were compared: GSU-A, GUR-A, GUM-A. The impression was performed with polyvinyl siloxane impression material and a standardized tray to control variables. The models were cast in standardized matrix with type IV plaster stone. For the measurements, a software (Leica QWin) received the images from a video camera coupled to a Leica stereomicroscope. The KruskalWallis test, associated with Dunn's test, with significance level of 5%, was applied. For straight implants, statistically significant difference between groups (KruskalWallis test; p <0.001) was observed. The difference was between GUR-R (186.71 µm) and master model (110.40 µm) and between GUR-R and the other groups (GSU-R: 108.27 µm and GUM-R: 92.98 µm). For angled implants, no statistically significant difference (p = 0.492) was found between the groups (MM-A: 68.52 µm; GSU-A: 60.80 µm; GUR-A: 56.54 µm; GUM-A: 69.33 µm. ..(Complete abstract electronic access below)
6

Tenacidade à fratura e dureza de porcelana feldspática adicionada de óxido de zircônio : efeito da concentração e da temperatura de sinterização /

Ribeiro, João Gustavo Rabelo. January 2009 (has links)
Resumo: O objetivo deste estudo foi avaliar o efeito da adição de óxido de zircônio, em diferentes concentrações e temperaturas de sinterização, na tenacidade à fratura (KIC) e na dureza Vickers (HV) da porcelana feldspática Duceragold. Foram confeccionados discos cerâmicos (9,0 x 3,0mm; n=10) para os grupos: (G1) Duceragold sem adição de ZrO2, (G2) Duceragold adicionada de 1% de ZrO2, (G3) 2% de ZrO2, (G4) 3% de ZrO2, (G5) 4% de ZrO2, (G6) 5% de ZrO2, (G7) 6% de ZrO2 e (G8) 7% de ZrO2, sinterizados a: (a) 800 ºC, (b) 850 ºC, (c) 900 ºC, (d) 950 ºC e (e) 1000 ºC, totalizando 400 corpos-de-prova. Após a sinterização, em forno Alumini Press, procedeu-se sua inclusão e polimento até lixa 1500 em politriz. A HV foi mensurada em durômetro Buelher, com carga de 9,8 N, por 20 segundos; as imagens obtidas foram capturadas por meio de câmera JVC e os cálculos de KIC, executados com auxílio do software Laica. Para observação da superfície das amostras, foram realizadas fotomicrografias por MEV. Os resultados de KIC e HV foram submetidos a ANOVA e teste de Tukey (p!0,05). Observou-se que, independentemente da temperatura de sinterização, o aumento da concentração de óxido de zircônio, aumenta o KIC, todavia, a partir de 6%, a HV diminui; independentemente da concentração, o aumento da temperatura de sinterização proporciona aumento dos valores de HV, contudo, temperaturas de 950ºC e 1000ºC diminuem o KIC; com o aumento da concentração de óxido de zircônio e da temperatura de sinterização, aumentam o número de poros tanto na fase vítrea da porcelana, quanto na fase dispersa de zircônia. Considerando as propriedades estudadas e a caracterização da superfície, pode-se observar que as amostras com adição de até 4% de óxido de zircônio à porcelana feldspática Duceragold, sinterizadas em temperaturas de até 900ºC apresentam-se como as mais promissoras. / Abstract: The objective of this study was to evaluate the effect of adding zirconium oxide at different concentrations and temperatures of sintering, on the fracture toughness (KIC) and Vickers hardness (HV) of feldspathic porcelain Duceragold. Ceramic discs were prepared (9.0 x 3.0 mm, n = 10) for the groups: (G1) Duceragold without the addition of ZrO2, (G2) Duceragold added 1% of ZrO2, (G3) 2% of ZrO2, (G4) 3% of ZrO2, (G5) 4% of ZrO2, (G6) 5% of ZrO2, (G7) 6% of ZrO2 and (G8) 7% of ZrO2, sintered at: (a) 800 ºC, (b) 850 ºC, (c) 900 ºC, (d) 950 °C and (e) 1000 ºC, totaling 400 specimens of the samples. After sintering at Alumini Press furnace, inclusion and polishing by sandpaper polishing (# 1500) were proceeded. The HV was measured in a Buelher durometer, with a load of 9.8 N for 20 seconds, the images were captured using a JVC camera and calculation of KIC, performed with the aid of software Laica. To observe the surface of the samples were performed by SEM photomicrographs. The results of KIC and HV were submitted to ANOVA and Tukey's test (p ! 0.05). It was observed that regardless of sintering temperature, the concentration of zirconium oxide, increases the KIC, however, from 6%, HV decreases; regardless of the concentration, the increase of sintering temperature gives increased HV values, however, temperatures of 950 °C and 1000 °C decrease the KIC; with increasing concentration of zirconium oxide and sintering temperature, increase the number of pores in the vitreous and dispersed phase of zirconia. Considering the studied properties and characterization of the surface can be observed that the samples with the addition of up to 4% zirconium oxide in Duceragold feldspathic porcelain, sintered at temperatures up to 900 º C are presented as the most promising. / Orientador: Carlos Alberto dos Santos Cruz / Coorientador: José Cláudio Martins Segalla / Banca: Paulo Henrique dos Santos / Banca: Marcos Ribeiro Moysés / Banca: João Neudenir Arioli Filho / Banca: Renata Garcia Fonseca / Doutor
7

Análise in vitro da precisão de técnicas de esplintagem na moldagem de implantes no esquema all-on-four /

Pimentel, Gustavo Henrique Diniz. January 2014 (has links)
Orientador: Francisco de Assis Mollo Junior / Banca: Marco Antônio Compagnoni / Banca: Janaína Habib Jorge / Banca: Estevam Augusto Bonfante / Banca: Ricardo Faria Ribeiro / Resumo: O assentamento passivo de próteses sobre implantes é fundamental para que o sucesso da reabilitação seja alcançado. A precisão na moldagem de transferência é um dos principais fatores responsáveis por assegurar a adaptação dos componentes. Dentre as várias técnicas propostas, não existe consenso sobre qual é a mais eficaz. O objetivo do presente estudo foi avaliar "in vitro" a precisão de diferentes métodos de união de transferentes quadrados na moldagem de implantes paralelos e angulados instalados em curva. Para a obtenção do modelo mestre, matrizes metálicas em alumínio foram confeccionadas, apresentando quatro perfurações, em forma de curva, paralelas (prótese protocolo convencional) e anguladas (esquema "All-on-four"). Foram fixados os análogos e, sobre eles, foram confeccionadas estruturas metálicas. Para os implantes retos, os grupos foram divididos em GSU-R: transferentes quadrados sem união; GUR-R: transferentes quadrados unidos com bastões de resina acrílica autopolimerizável pré-fabricados e GUM-R: transferentes quadrados unidos com haste metálica, cianoacrilato e resina acrílica autopolimerizável. Para os implantes angulados, as mesmas técnicas foram comparadas: GSU-A, GUR-A, GUM-A. A moldagem foi realizada com silicone de adição e moldeira rosqueada para controlar variáveis. Os modelos foram vazados em matriz padronizada com gesso pedra tipo IV. Os modelos obtidos foram armazenados à temperatura ambiente por no mínimo 120 horas até que as medidas das fendas fossem realizadas. Foi utilizada uma lupa LEICA acoplada a uma câmera de vídeo colorida e as mensurações das fendas foram realizadas no programa LEICA QWin. Foi aplicado o teste de Kruskal-Wallis, complementando pelo teste de Dunn, com nível de significância de 5%. Para os implantes retos, foi observada diferença estatisticamente significante entre os grupos...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Passively fitting superstructures are a prerequisite for long-lasting osseointegration of dental implants. Accurate transfer of the implant positions from the mouth to a definitive stone cast is a crucial step for ensuring the adaptation of components. Among the various techniques proposed, there is no consensus on which one is the most effective. The aim of this study was to evaluate "in vitro" the accuracy of different splinting methods in the impression of implants under standardized laboratory conditions. To obtain the master model, an aluminum metal matrix was developed, presenting four perforations, parallel (simulating conventional prosthesis and angled (simulating "All-on-four" system). Analogs were fixed and, on them, metal structures were fabricated. For straight implants, the groups were divided into GSUR: non-splinted square transfers; GUR-R: transfers splinted acrylic resin; GUM R: transfers splinted with metal rod, cyanoacrylate and acrylic resin. For angled implants, the same techniques were compared: GSU-A, GUR-A, GUM-A. The impression was performed with polyvinyl siloxane impression material and a standardized tray to control variables. The models were cast in standardized matrix with type IV plaster stone. For the measurements, a software (Leica QWin) received the images from a video camera coupled to a Leica stereomicroscope. The KruskalWallis test, associated with Dunn's test, with significance level of 5%, was applied. For straight implants, statistically significant difference between groups (KruskalWallis test; p <0.001) was observed. The difference was between GUR-R (186.71 µm) and master model (110.40 µm) and between GUR-R and the other groups (GSU-R: 108.27 µm and GUM-R: 92.98 µm). For angled implants, no statistically significant difference (p = 0.492) was found between the groups (MM-A: 68.52 µm; GSU-A: 60.80 µm; GUR-A: 56.54 µm; GUM-A: 69.33 µm. ..(Complete abstract electronic access below) / Doutor
8

Aspectos relacionados ao tempo de duração de trabalhos protéticos à luz da reparação de danos / Aspects related to the term of prosthetic work to damage repair

Fernandes, Mário Marques 08 February 2010 (has links)
Orientador: Eduardo Daruge Júnior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-16T11:53:01Z (GMT). No. of bitstreams: 1 Fernandes_MarioMarques_M.pdf: 1226077 bytes, checksum: 97df8894df2b17248ffd415071265aba (MD5) Previous issue date: 2010 / Resumo: Na área clínica pericial a odontologia legal se depara com a necessidade de avaliar qual seria o tempo de duração de trabalhos odontológicos proféticos, observando-se na literatura uma falta de padronização desse período. Não existe consenso também sobre as características dos trabalhos quanto ao quesito qualidade, bem como em relação ao tempo de guarda dos prontuários. Em vista destes dados o presente estudo buscou: a) verificar o grau de conhecimento do Cirurgião-dentista especialista em prótese dentária da Cidade de Porto Alegre/RS sobre aspectos relacionados ao tempo de duração de trabalhos protéticos, b) destacar o saber dos protesistas sobre legislação aplicada no exercício profissional e nas relações com a reparação de danos envolvendo trabalhos de prótese, e c) evidenciar os aspectos clínicos pertinentes ao tema. O presente estudo, após aprovado pelo Comitê de Ética e Pesquisa sob protocolo 118/2007, foi realizado por meio de questionários entregues nos 222 consultórios constantes na listagem fornecida pelo CRORS, pessoalmente e via correios. A amostra pesquisada constituiu-se de 143 questionários respondidos (n=143), ou seja, 64,4% do número de profissionais existentes a época. Quanto ao perfil dos pesquisados, verificou-se que 53,8% (n=77) eram do sexo feminino, a maioria 29,4% (n=42) dos profissionais respondentes se encontrava na idade entre 31 e 40 anos. O setor de trabalho que mais se destacou foi o particular, representando 53,8% (n=77). Já no que se refere ao tempo de exercício profissional, foi mais prevalente o período entre 16 e 20 anos, com 19,6 % (n=28). Quanto ao conhecimento sobre odontologia legal, 47,6% (n=68) dos questionados declararam não ter tido ministrados conteúdos relativos a essa área. Nos cruzamentos estatísticos, mostrou-se significativo a associação do conhecimento sobre o tempo de duração das reabilitações e o setor de trabalho dos protesistas (p=0, 002). Concluiu-se que: a) Existe entre os especialistas em prótese dentária da Cidade de Porto Alegre um conhecimento adequado sobre os aspectos relacionados ao tempo de duração de trabalhos de prótese; b) a maioria dos protesistas não foi instruída em odontologia legal e desconhece, de forma consistente, as normas éticas e legais pertinentes a profissão, bem como a legislação relacionada à reparação de danos envolvendo trabalhos reabilitadores de prótese; e c) pela necessidade de entendimento dos aspectos clínicos envolvidos na avaliação dos trabalhos de prótese (independente do tipo), a perícia para verificação da culpa deverá ser realizada por um Cirurgião-dentista odontolegista e com experiência irrefutável na área de prótese dentária. O período estimado sobre a duração dos trabalhos, quando avaliado em perícias odontolegais deve ser verificado com base nas responsabilidades de cada um dos envolvidos no trabalho: protesista, paciente e laboratório, atribuindo as reabilitações protéticas uma obrigação de meio / Abstract: In the examination clinical area, forensic dentistry faces the necessity of evaluating which would the prothetic dentistry work duration be, observing a lack of standard in literature, concerning time. There isn't any consensus about work features concerning quality neither in relation to how long the patient's records are kept. In view of these data, the current study aimed to: check the dentist's (CD) level of knowledge, specialized in dental prothesis in the city of Porto Alegre/RS on aspects linked to the duration of prothetic work, b) highlight the prothesist's knowledge on the law applied to the job and to relations with damage repairs involving prothesis; and c) evidence clinical aspects connected to the theme. The current study, after having been aproved by the Ethics and Research Commitee, protocol 118/2007, was performed through questionnaires delivered at the 222 offices from the list given by CRORS, personally and mainly by mail. The research sample had 143 questionnaires answered (n=143), in other words, 64,4% of professionals then. Regarding the respondents profile, it was found that 53,8% (n=77) were female, most of professionals who responded 29,4% (n=42) were between 31 and 40 years old. The work sector that mostly highlighted itself was the private one, representing 53,8% (n=77). Refering to professional time experience, it was most important the period between 16 and 20 years, 19,6 % (n=28). In terms of forensic odontology knowledge, 47,6%(n=68) of respondents said contents about the area had not been provided. When crossing the statistics, it was important the association of knowledge over lasting time rehabilitation and the prothesist working sector. (p=0,002). In conclusion: a) There is an adequate knowledge on the time a prothesis work lasts among the dentists specialized in dental prothesis in the city of Porto Alegre b) most of prothesists were not skilled in Legal Odontology and are not aware, in a large scale, of ethical and legal rules of the profession, as well as the law related to damage repairs, concerning prothesis rehabilitation work; and c) By the need for understanding clinical aspects involved in the evaluation of prothesis work (regardless the kind of), the checking for the guilty identification must be done by a Legal CD with forensic expertise who has an incontestable experience in dental prothesis. The estimated time for the work duration, when evaluated in forensic dentistry examination must be checked based on responsibilities of each one involved in the work: prothesist, patient and laboratory, giving the prothetical rehabilitation the status of field / Mestrado / Odontologia Legal e Deontologia / Mestre em Biologia Buco-Dental
9

Processamento de próteses totais: influência de 4 técnicas na alteração daposição dos dentes artificiais. / The processing of complete denture: influence of four techniques in artificial teeth movement.

William Barnabé 03 April 2000 (has links)
O processamento de resinas acrílicas utilizadas na confecção de bases de prótese envolve alterações dimensionais e distorções da base e movimentação dos dentes artificiais que podem levar à não utilização das próteses por desadaptação, dificuldade de engrenamento dos dentes e estética. Esse estudo avaliou a relação entre a movimentação dos dentes artificiais com os procedimentos de inclusão, prensagem e polimerização das bases de próteses totais. Foram utilizadas 64 amostras, divididas em quatro grupos de 16 (8 inferiores e 8 superiores) que receberam o seguinte tipo de inclusão, prensagem e processamento: a) grupo 1: neste grupo todas as amostras foram incluídas em muflas reforçadas de fibra de vidro, com muralha de silicona, prensagem por uma hora e polimerização em microondas, b) grupo 2: neste grupo todas as amostras foram incluídas em muflos metálicos, com muralha de silicona, prensagem por 12 horas e polimerização em banho de água, utilizando o ciclo de curta duração, c) grupo 3: neste grupo todas as amostras foram incluídas em muflas reforçadas de fibra de vidro, adaptadas para injetora de acrílico, com muralha de gesso pedra e polimerização em microondas, uma hora após a injeção do molde e d) grupo 4: neste grupo todas as amostras foram incluídas em muflos metálicos, com muralha de silicona, prensagem por uma hora e polimerização em banho de água, utilizando o ciclo de curta duração. Com os resultados obtidos podemos concluir que: a) todas as amostras sofreram contração após o processamento, b) a técnica com menor movimentação dos dentes artificiais foi a técnica 1, que apresentou diferença estatisticamente significativa em relação às demais c) quando comparados os arcos superiores e inferiores, independente da técnica e das medidas avaliadas, não se percebeu diferença estatisticamente significativa d) O tempo de prensagem, após a inclusão e antes da polimerização das próteses, interferiu na movimentação dos dentes artificiais e e) a medida que apresentou maior alteração foi a distância entre os molares, com diferença estatisticamente significativa com as demais. / The processing of acrylic resins used in the construction of complete denture bases involve dimensional alterations, distortion and artificial tooth movement which may prevent the prosthesis from being used due to discomfort, inadequate occlusion and esthetics. This study evaluated the relationship between artificial tooth movement, with the procedures of inclusion, compression and polymerization of complete dentures bases. The sixty-four samples utilized were divided into four groups of 16 (8 lower and 8 upper) which received the following type of inclusion, compression and processing: a) group 1: in this group all samples were included in resin-fiber reinforced flasks, with a silicone mould, compression for one hour and microwave polymerization; b) group 2: in this group all samples were included in metallic flasks, with a silicone mould, compression for 12 hours and thermopolymerization in water bath, using a short duration cycle; c) group 3: in this group all samples were included with gypsum stone mould using an acrylic injector to insert the resin inside the flasks, followed by microwave polymerization, one hour after mould injection and; d) group 4: in this group all samples were included in metallic flasks, with a silicone mould, compression for one hour and thermopolymerization in water bath, using short duration cycle. According to the results the following conclusions were drawn: a) contraction was observed in all samples after processing; b) group 1 presented statistically significant less artificial tooth movement, relative to the others; c) comparing the upper and lower arches, regardless of the technique and measurements evaluated, no statistically significant difference was found; d) the compression time following inclusion and before prostheses polymerization had a negative effect on artificial tooth movement and e) the biggest discrepancies were found in the distance between contralateral molars, with statistically significant difference to other measurements.
10

Estabilidade do parafuso do intermediário em implantes de conexão externa e interna, após ensaio de fadiga

Paulo César Pinheiro Feitosa 22 August 2007 (has links)
A reabilitação de pacientes desdentados totais e parciais com próteses implantossuportadas constitui, atualmente, um dos tratamentos de eleição na Odontologia. O sucesso do tratamento está relacionado com a precisão e adaptação dos componentes, assim como com a estabilidade da interface implante/intermediário quando submetida a cargas durante a mastigação. A restauração unitária é biomecanicamente mais complexa, principalmente em se tratando de unidades posteriores. O objetivo deste trabalho foi comparar o valor de torque e de destorque do parafuso de intermediários de hexágono externo, hexágono interno e cone morse em restaurações unitárias, antes e após ensaio mecânico. Quinze corpos de prova foram divididos em três grupos: Grupo A implante de hexágono externo, Grupo B implante de hexágono interno e Grupo C implante cone morse. Sobre os implantes foram parafusados munhões universais e sobre estes cimentadas coroas metálicas. As amostras foram submetidas a ensaio mecânico de um milhão de ciclos, com freqüência de 8 ciclos por segundo e sob carga de 400 N. Aplicação e registro dos valores de torque e destorque dos parafusos do intermediário foram realizados antes e depois do ensaio. Por meio do teste de Tukey, adotando-se nível de significância de 5%, não foi observada diferença estatisticamente significativa entre os valores de destorque inicial e final das amostras dentro de um mesmo grupo. Porém, foi evidenciada diferença estatisticamente significativa dos valores iniciais entre os grupos A e C e dos valores finais entre os grupos A e B, A e C, B e C. A conexão cone morse apresentou os maiores valores de destorque inicial e final, mostrando-se mais estável. / Currently the rehabilitation of patients totally or partially toothless with implantsupported prothesis constitutes a primary choice treatment in Dentistry. The success of the treatment is related to the precision and adaptation of components, as well as to the stability of the implant/abutment interface submitted to mastication loads. The unitary restoration is bio-mechanically more complex, especially for the posterior units. The objective of this study is to compare values of torque and detorque recorded for the screw of the abutment with external hexagon, internal hexagon and morse taper in unitary restorations, before and after the mechanical test. Fifteen samples were divided into three groups: Group A implant of external hexagon; Group B implant of internal hexagon and Group C morse taper implant. Universal abutments were torqued over the implants and metallic crowns were cemented over the abutments. Samples were submitted to mechanical test of a million cycles, frequency of 8 cycles per second and load equivalent to 400 N. Application and recording of torque and detorque values at screws of the abutment were carried out before and after the mechanical test. Results of a Tukey test with a 5% level of significance showed no statistically significant difference between the initial and the final detorque values in samples of the same group. However, a statistically significant difference was found for the initial detorque values between the groups A and C and for the final detorque values between A and B, A and C, B and C. The Morse taper connection showed higher values of initial and final detorque values, therefore bearing increased stability.

Page generated in 0.0809 seconds